Loading...
07-2392 (AR)_t:� P.O. BOX 1504 78=495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: C07-00002392 Owner: Property Address: 77740 CALLE •ORIZABA BANK. OF THE WEST APN: 658-260-001- - - 300 SOUTH'GRAND Application description: ADDITION RESIDENTIAL LOS ANGELES, CA Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 70000 Applicant: Architect or Engineer: alp ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury. that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B C6 9 License No.: 563542 Date: 2�Q6ntr tor—t_ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec: 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not buildor improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY ' I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). . Lender's Name: Lender's Address: LQPERA11T AVE 90071 Contractor: N CASCO COAST TO COAST 13630 IMPERIAL-HIGHWA SANTA FE SPRINGS, CA (562)921-4567 .Lic. No.: 563542 VOICE (760)-777-7012 y FAX (760) 777-7011 INSPECTIONS (760) 777-7153 9/14/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: . _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FLTND Policy Number 1754416-2006 I certify that, in the performance of the work for which this permit is issued, I shall not employ any. person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code I i rose w'sions. 7L a � Datey� PApplicant _ v WARNING:. FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST -OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE -LABOR CODE, INTEREST, AND ATTORNEY'S FEES. _ APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the . conditions and restrictions set forth on this application. - - 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application„ the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this untyy to enteron the above-mentioned property for inspection puro_ o C ''77�, �' � Date: 4- Signature (Applicant or Agent;: Application Number 07-00002392 Permit BUILDING PERMIT Additional desc . Permit Fee 504:50 Plan Check Fee 327.93 Issue Date Valuation . . . . 70000 Expiration Date 3/11/08 Qty Unit Charge Per Extension BASE.FEE 414.50 20.00 4.5000 THOU BLDG 50,001-100,000 90.00 Permit . . ELECT - ADD/ALT/REM Additional desc-. Permit Fee 18.43 Plan Check Fee .' 4.61 Issue*Date . . . Valuation. 0 , Expiration Date _ 3/'11/08 Qty Unit Charge Per Extension - BASE FEE 15.00 98.00 .0350. ELEC NEW RES - 1.OR 2 FAMILY 3.43 Permit MECHANICAL Additional desc . Permit Fee 59.00 Plan Check Fee 14.75. Issue Date . . . Valuation . . . 0 Expiration Date -3/11/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00_ 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . PLUMBING Additional desc . Permit Fee . . . . 78.00 PI'an Check Fee 19.50 Issue Date . . . . Valuation. -. 0 Expiration Date 3/11/08 Qty Unit Chargee Per Extension BASE FEE 15.00 10.00 .6.0000 EA PLB FIXTURE 60.00 1.00 3.0000 EA PLB WATER INST/ALT/REP. 3.00 ----------------------------------------------------------------------------- Special Notes and Comments rem / addition 89 sq..ft.permit expired LQPERMIT Application Number .. 07-00002392 f ---- ---------------------- Special Notes and Comments this is a replacement set. September 13, 2007 4:55:07 PM jjohnson. this permit permit 05-2540. Other Fees ENERGY REVIEW FEE 32.79 STRONG MOTION (SMI) - RES 7.00 Fee summary Charged Paid Credited Due Permit Fee Total 659.93 .00 .00 659.93 Plan Check Total 366.79 .00 .00 366.79 Other Fee Total 39.79 .00 .00 39.79 Grand Total 1066.51 a 00 00 1066.51 LQPERDIIT - Bin City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Nninit # L Project Address: "77-7qo C,2,qe_ or,?, Owner's Name: &g4k o�"e_ Wc?%4- A. P. Number: C?5s - 2 (, 0^ V t Address: ou &2.,h Aare.cal Legal Description: Tr 14 4 IG I Contractor:Telephone: Co sc, a Cv2s-i 4- C-U,2�s f city, ST, Zip: Los- Xngej e-s CA .100-11 imp Address: 3 Project Description: City, ST, Zip:- tz Fe _<,o-c. P-A 9 o -7'0 b6 I Telephone: J627S52-0 State Lic. #: 15655 City Lic. #: Ylew Arch., Engr.,..Designer. eAo4 c-an-l-wesA �c_ ct am%A 1",Cl kr_s Address: f City, ST, Zip: `;?-z4 Telephone:NO W Im Construction Type: Occupancy:. State Lic. #: Project type (circle one): New AcIft Alter Repair Demo Name of Contact Person:, Sq. Ft.- # Stories: Telephone# of Contact Person:' lj et 55 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd RecId TRACKING PERMIT FEES Plan Sets Plan Check submitted el� Item Amount Structural Calcs. Reviewed, ready fo corrections ; Plan Check Deposit Truss Calci. Called Contact Pe"-'--- d Plan* Check Balance Energy Calcs. Plans Picked up ft-ft'1611 Construct:on Flood plain plan Plans resubmitted Mechanicill Grading plan 2"d Review, ready for corrections/issue Electrical, Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up At S.M.I. H.O.A. Approval Plans resubmitted a. Grading' IN HOUSE:- ""Review, ready for corrections/issue Developec- Impact Fee Planning Approval Called Contact Person At.I.P.P. Pub. Wks. Appr Date of permit issue School Fees (k Total Pez m it Fees 00 ftfa yup ;�Ie' Title 24 Report for: Santa Rosa Cove 77 740 Calla Orizaba La Quinta, CA 92253 Project Designer: Rebaca Dennis P.O. Box 5187 - La Quinta, CA 92248 760 578 9855 Report Prepared. By: Luz Fregoso CITY OF LA UINTA 44525 Avenue Portola BUILDING SAFETY DEPT. - Palm Desert, CA 92260 _• ' - VED ---APP 760 837-9009 v., . FOR COiNST UCTION Job Number: L1024 Date: AUG 2 2 2007 8/21/07 By_ - The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. " EnergyPro 4.2 by EnergySoft Job Number: L1024 User Number: 5982 Lnergyrrro 42 Dy Lnergysott Job Number: L1024. User Number: 5982 r , Certificate'Of Comoliance : Residential (Part 1 of 4) CFA R Santal'osa_Ctice RJ Single Family ❑ Addition Total Conditioned Floor Area: 812J] -07 - Project Title _7=0_C aUa_O riza b a-La_Quinta Roof Wood- -2,19A_ ❑ Multi Family Date Project Address 2,194 ft2 Building Front Orientation: Building Permit # 1uz_Ceos_o Documents ion Author 0 ft2 (760) 837-9009 Telephone 0..5.0.0 _InsuL _LZ0_0_ x.8.0_ plan Check/Date -EaeTovPro CompliXtIce Method 2,292 ft2 15 Climate Zone -0-102- R_13_ _E2_0_0_ 0_ 9.0 Field Check/Date Average Ceiling Height: TDV Standard Proposed Compliance Avg. U: 0.37 kBtu/sf-yr Design Design Margin 22.7% Avg. Space Heating 3.54 2.90 0.64 BUILDING ZONE Space Cooling . 82.85 81.68 1.17 Zone Name Fans 12.55 12.43 0.12 Area Domestic Hot Water 10.72 10.72 0.00 2 Pumps 0.00 0.00 0.00 Totals 109.65 107.72 1.93 Percent better 1. Building Type: RJ Single Family ❑ Addition Total Conditioned Floor Area: 2,292 ft2 Roof Wood- -2,19A_ ❑ Multi Family n Existing + Add/Alt Existing Floor Area: 2,194 ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: 0..5.0.0 _InsuL _LZ0_0_ x.8.0_ Natural Gas Slab on Grade Area: 2,292 ft2 Fenestration: -0-102- R_13_ _E2_0_0_ 0_ 9.0 Wall Wood- 33_ Average Ceiling Height: 10.0 ft Area: 520 ft2 Avg. U: 0.37 Number of Dwelling Units: 1.00 Ratio: 22.7% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .New_2+/C -2,292 22 920 1-00_ Conditioned- _Setback- 2 -n/n OPAQUE SURFACES Insulation Act. Altered_ Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood- -2,19A_ -0_035_ _R3.0_ _R=0-0_ _0_ 1.8 Call_ 99.9 0102 _R Aa_ X0_0 90_ 9A. 1tlCall_ Wood_ 2Z0 _0JD2 R-13 0'`0_0 -180---9-0 .Door None- 20_ -0.5.0.0_-Ins.uL -R=0_0_ x.80_-9.0 New D9.or None_ 20 0..5.0.0 _InsuL _LZ0_0_ x.8.0_ 90 Wall- Wood_ 1.0.0.8_ _0102 R-13_ JZ0_0 _2Z0__9.0 Wall - Wood- -272 -0-102- R_13_ _E2_0_0_ 0_ 9.0 Wall Wood- 33_ -0-102- R-13_ _R=00_ _225_ 9.0 Roof_ al_V_ood_ 9.8_ -0_.0.35.0.30_ __R-_0_0_ 0_x.8 Call_ Wood_ 6.0_ _0..102 -R=13 __R-_0_0_ -0--90 Gains Condition Y / N Status JA IV Reference Location / Comments Altered_ _02=A10_(.E=02A1.0Y .Existing_Etoor Altered_ _0.9 A3_(E=0.9_\3)_ ExistingFloor Altered_ _0.9=A3_(.E_0.9_A3)_ Existing -8 r Existing_ 28=A3 Existing Floor N.ew 28=A3 .Existing -Boor Altered_ _0.9_3_(.E=0.9A3.)_ ExistingFJoor Altered- _0.9=A3-(E=Q9=A3.)_ Existing El- Altered- _0.9_A3_E=0.9=A3.)_ Existing- loor New _02=A10 Addition New _0.9=A3 Addition EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:3 of 11 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Santa Rosa Cove 8/21/07 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGCz True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 1_-Mcidow Righ.t_(E.)_ 2 Window Right (Q -27-5 22.0 -0_37-0 NERC _0.-32 NERC -9.0_ 0.370 NFRC 0_32 NFRC 90 _9.0_ Exisfing_LVALC_6200AI.umLLow=E F_xisting-Roor. 90 Existing_IWC 6200 Alum/Low-E Existin Floor 3 4 5 Window Right(E)_ Window Right (E) Window Right (E) 22.0 17.4 17.4 0.370 NFRC 0_32 NFRC 0.370 NFRC 0_32 NFRC 0.370 NFRC 0_32 NFRC 90 90 90 90 Existing_IWC 6200 Alum/Low-E 90 Exlstinp_IWC 6200 Alum/Low-E 90 Existing IWC 6200 Alum/Low-E Existing Floor Existing Floor Existing Floor 6 Window Right (E)_ 8.6 0.370 NFRC 0_32 NFRC 90 90 Existing -IWC 6200 Alum/Low-E Existin Floor 7 8 Window Right (E) Window Right (E) 48.0 8.6 0.37 NFRC 0,32 NFRC 0.370 NFRC 0.32 NFRC 90 90 99_ i i _IWC 6200 Alum/Low-E 90 Existing IWC 6200 Alum/Low-E -Existing Floor Existing Floor 6 Window Right -(E)_ 17.4 937-0 NFRC-Q-32-NFRC 90 90 Existing IWC 6200 Alum/Low-E Existin Floor _1_Q Window Rigllt_(E)_ 22.2 9. 79 NFRC 0.32 NFRC 90 90 Existing IWC 6200 Alum/Low-E ExiSlino Floor 11 Window Front (S)_ 17.4 0.370 NFRC 0_32 NFRC 180 90 Existin _IWC 6200 Alum/Low-E Existing Floor 12 Window Front (S)_ 20.8 0.370 NFRC 0_32 NFRC 180 90 Existin _IWC 6200 Alum/Low-E Existing Floor 13 14 Window Er_ont_(S)_ Window Left (W)_ ---4_0 39.6 --0-37-0 NERC 0.32 _NF_BC --I@0_ 0.370 NFRC 0_32 NFRC 270 90 Existing_LW-C 62DOAI.um/Low=E Exi.sting-Eloor. 90 Existing -IWC 6200 Alum/Low-E Existing Floor 15 Window Left (W_ 20.2 0.370 NFRC 0_32 NFRC 270 90 Existing_IWC 6200 Alum/Low-E Existing Floor 16 Window Left (W) 17.4 0.370 NFRC 0_32 NFRC 270 90 Existin _IWC 6200 Alum/Low-E Existing Floor 17 Window Left (W) 22.2 0.370 NFRC 0_32 NFRC 270 90 Existing_IWC 6200 Alum/Low-E Existing Floor 18 Window Left (W) 22.2 0.370 NFRC 0_32 NFRC 270 90 Existing_IWC 6200 Alum/Low-E Existing Floor 12 Window Rear (NJ- 27.5 0-310 NERC 002 NFRC 0_ 90 xis i t _IWC 6200 Alum/Low-E Existing Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. Bug Screen -ffug INTERIOR AND EXTERIOR SHADING Window Insulation R -Val. Location Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. `Ext. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 Existing Floor Slab Perimeter 14 None No Insulation 26-A1 New 2 Bug Screen 0.76 5.0 3.0 10.0 0.1 10.0 10.0 3 Bug Screen 0.76 5.0 3.0 10.0 0.1 10.0 10.0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen -ffug 0.76 11 Screen 0.76 12 Bug Screen 0.76 7.0 2.0 10.0 0.1 10.0 10.0 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 8.0 6.0 13.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length Insulation R -Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 156 None No Insulation 26-A1 Existing Existing Floor Slab Perimeter 162 None No Insulation 26-A1 Existing Existing Floor Slab Perimeter 14 None No Insulation 26-A1 New Addition Run Initiation Time: 08/21/07 11:34.35 Run Code: 1187721275 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Santa Rosa Cove " 8/21/07 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 True Cond. Azm. Tilt Stat. Glazing Type � Location/ Comments 20-wjndo.w—Rear_(N)- 17.4 —0_37-0_NERC__0_32 NFRC. 0__9.0_ Existing_IWC_620.0-A1um/Low=E Existing-ROJQ 21 Window Front (SW) 17.4 0.370 NFRC 0_32 NFRC. 225 90 Existing' IWC. 6200 Alum/Low-E Existin Floor 22 Window Rear (N)_ 17.4- 0.370 NFRC 0_32 NFRC 0 90 New IWC 6200 Alum/Low-E Addition 23 Window . Rear (N) 48.0 0.370 NFRC 0_32 NFRC .0 90 New IWC 6200 Alum/Low-E Addition 24 Window Rear (N)_ 17.4 0.370 NFRC 0_32 NFRC 0 90 New IWC 6200 Alum/Low-E Addition ' r 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Run Initiation Time: 08/21107 11:34:35 Run Code: 1187721275 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:5 of 11 . PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 08/21107 11:34:35 Run Code: 1187721275 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:5 of 11 . Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Santa Rosa Cove 8/21/07 Project Title Date HVAC SYSTEMS r' Heating Minimum Cooling Minimum Condition Thermostat Location Type Eft Type Eff Status Type New A/C Central Furnace ' 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling New A/C Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Duct Condition Ducts ' Location 'R -Value Status Tested? Attic 6.0 Existing Yes F WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in, Input , Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Standard Gas 50 gal or Less Small Gas Kitchen Pipe Ins 1 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Len tg h (ft) Add 1/2" Control # HP Type In Plenum Outside - Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS. f COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Title/Firm: Rebeca Dennis Title/Firm: Luz Fregoso Address: P.O. Box 5187 Address: 44525 Avenue Portola La Quinta, CA 92248 Palm Desert, CA 92260 Telephone: 760 578 9855 Telephone: (760) 837-9009 Lic. #: S 22-D7 f .2 o (signature) (date) (s' at ) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: f Certificate Of Compliance : Residential .,(Part 4 of 4) CF -1 R Santa Rosa Cove 8/21/07 Project Title Date .Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Existing Water Heater "Standard Gas 50 gal or Less" has an EF less than the Table R3-11 CEC Default Vintage Values. r M1• T s Required Verification n this section require field testing and/or verification by, a certified home energy rater under the supervision of a CEC- -rr. ,...�., r....... ...,...a .. ..rr.,...o...o�....y .... a.........�..,Q .or....o.........o .., installation certificate. Plan Field The HVAC System "New A/C " incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. !II +I Run Initiation Time: 8/21/07 11:34:35 Run Code: 1187721275 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:7 of 11 t s ! ' Mandatory Measures Summary:` Residential (Page 1 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance . requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 01 DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturer's labeled R -Value: f§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only.' § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. El ❑X E] - ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ER ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ENFORCE - ❑ N/A DESIGNER MENT ❑ (SHGC), and infiltration certification. , ❑ ❑ ❑ a El El 11 ; ❑ 0 ❑ ❑ ❑ O ❑ ❑ El ❑X E] - ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ER ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient ❑ ❑X ❑ (SHGC), and infiltration certification. , 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ El- ❑ Space Conditioning, Water Heating and Plumbing System Measures ; § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ '- ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑., . ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1+. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A, 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed " ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft , User Number: 5982 Job Number: L1024 Page:8 of 11 N r ' Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R. NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑X❑ ❑ ' 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. _ 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. ' 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. X 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility'rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1� 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). ` § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:9 of 11 Residential Kitchen Lighting Worksheet WS -5R. ' Santa Rosa Cove 8/21/07 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined In Table 150-C. Luminaires that are not high efficacy must be switched separately. ' Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. - High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 26w Compact Fluorescent Quad 2 Pin Yes X No '27.0 x 11 = 297 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or ' Total A: 297 B: 0 COMPLIES IF A z B YES RNo D EnergyPro 4.2 by EnergySoft " User Number: 5982 Job Number: L1024 d t� F IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santa Rosa Cove 8/21/07 SYSTEM NAME FLOOR AREA New A/C 2,292 Number of Systems 1 Heating System Output per System 120,000 Total Output (Btuh) 120,000 Output (Btuh/sgft) 52.4 Cooling System Output per System 61,000 Total Output (Btuh) 61,000 Total Output (Tons) 5.1 Total Output (Btuh/sqft) 26.6 Total Output (sgft/Ton) 450.9 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 0.44 Airflow (cfm/Ton) 196.7 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARl conditions 26.0 OF 30 ;0 Outside Air 0 cfm 70.4 of 70.4 OF 70.4 of EM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,459 38,814 -582 -4,476 47,634 0 85.2 l 64.1 of 85.2 / 64.0 of 55.0 / 53.2 of 5,572 4,941 0 0 0 0 0 0 0 Outside Air 0 - 0 5,572 4,941 49 958 -582 57 517 American Standard, Inc. 4A7A4060C 42,367 11,544 120,000 Total Adjusted System Output42,367 11,544 120,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ,earn Temperatures at Time of Heating Peak) 65.0 of Supply Fan Heating Coil 1000 cfm k Return Air Ducts `S Supply Air Ducts 60.4 of ROOMS 75.0 OF I OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 of 85.2 l 64.1 of 85.2 / 64.0 of 55.0 / 53.2 of `' Supply Air Ducts .� Outside Air - 0 cfm Supply Fan Cooling Coil 60.2 / 55.3 of 1000 cfm ROOMS 36.8% R.H. 85.2/64.1 °F 80.0 ! 62.3 of Return Air Ducts I EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page: 11 of 11 I NUUCK,a uVi n na P.O. Box 5187 La Q u i nta, CA 92248 760 578 9855 Report Prepared By. 1 Luz Fregoso 44525 Avenue Portola Palm Desert, CA 92260 (760) 837-9009 Job Number: L1024 Date: pE _ ' 12/14/06 The EnergyPro computer program has been used to perform the calculations summarized in this compliance repo This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. .! . C—.e'`EnergyPro 4.2 by EnergySoftJob Number: L1024 User Number: 5982 Y Certificate Of Compliance: Residential 2,292 ft2 (Part 1 of 4) ,; CF -1 R santaRos.a_co�ce 2,194 ft2 Building Front Orientation: (S)180 deg Raised Floor Area: 1 2L1A1_06 Project Title _77_740_Calla_0-nzab_,n I al- .t Lista Fuel Type: Natural Gas Slab on Grade Area: Date Project Address Fenestration: Average Ceiling Height: Building Permit # F_reyos0. Area: 520 ft2 Avg. U: (760) 837-9009 _Luz Documents ion Author Ratio: 22.7% Avg. SHGC: Telephone Plan Check/Date -E.ner-VY/P_ro BUILDING ZONE INFORMATION 15 Field Check/Date 2om2li'9dce Method Zone Name Floor Area Volume Units Zone Type Climate Zone Hgt. Area TDV Standard Proposed Compliance -Setback- kBtu/sf-yj Design Design Margin Space Heating 4.33 3.99 0.34 { Space Cooling 95.56 91.47 4.09 ExistingJll000r Fans 14.36 13.85 0.51 Existing_F_loor Domestic Hot Water 10.72 10.72 0.00 Existing_Elo_or Pumps 0.00 0.00 0.00 Existing- loon Totals 124.97 120.03 4.94 '.Existing Flonr Percent better than Standard: Wall_ Wood- _1,00.8.0102-R13_-FL0_0_-2Z0__90 4.0% Existing- Building Type: [jd Single Family ❑ Addition Total Conditioned Floor Area: 2,292 ft2 ❑ Multi Family n Existing + Add/Alt Existing Floor Area: 2,194 ft2 Building Front Orientation: (S)180 deg Raised Floor Area: 0 .ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,292 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 520 ft2 Avg. U: 0.37 Number of Dwelling Units: 1.00 Ratio: 22.7% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area -Existing-EAU-&A/_C 9,292 -22,920 1-00_ Conditioned- -Setback- 2 -nla OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments .Root_ Wood- ---2-194--0-0-49- R -1-9- _R_0...0_ 0_ 1.8 1X ❑ Existing- _01=A4 ExistingJll000r Wall- 949 _0.102 -R_1.3_ --R-0 0_ 9.0_ 9.0 [ X ❑ Existing- _O9_A3 Existing_F_loor Wall_ Wood_ 2Z0 0.102 _R-13_ _R=O._0_ X8.0_ 9.0 [X ❑Existing_ 0.9_A3 Existing_Elo_or Door None- 20-0_50.0.1ns.uL _R_0_.0_ 1.80.9.0 IX ❑ Existin. g_ 28_A3 Existing- loon Door None_ 20_ 0 5.0.0_ _lnsuL fit=0_01.8.0_ 9.0. [X ❑ N.ew 28=A3 '.Existing Flonr Wall_ Wood- _1,00.8.0102-R13_-FL0_0_-2Z0__90 ❑Existing- _0.9=A3 Existing- Wall_ Wood- • 972 _0102 0_1.3_ -2=0_0_ 0__9.0 - ❑ Existing- _0.9=A3 ' ExistingJJlo-or Wall- Wood- 33_ _0102 -R=13_ X0_0_ -225.9.0 ❑ Existing- _0.9=A3 Existing- lo.or Wall_ Wood- 6.0-0_07A R_19_R=0_0_ 0_ 9.0 ❑New _0.9=A5 Addition ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ n - I ❑ F-1 ❑❑ ❑❑ F-1 F-1 ❑ ❑ A ❑ ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:3 of 11 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Santa Rosa Cove 12/14/06 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments _L. _ WiadowRight_(E)_ 2 Window Right (E_ -27.5_ 22.0 _0_3Z0 _NERC_ _032 0.370 NFRC 0_32 3 Window Right (E) 22.0 0.370 NFRC 0_32 4 Window Right (E) 17.4 0.370 NFRC 0_32 5 Window Right (E) 17.4 0.370 NFRC 0_32 6 Window Right (E)_ 8.6 0.370 NFRC 0_32 Z Window Right (E)_ 480 0.37 NFRC U-2 8 Window Right (E)_ 8.6 0.370 NFRC 0_32 9 Window Right (E)_ 17.4 037 NFRC 0-7 10 Window Right_(E)_ 270 22.2 03Z0_NFRC 0U3 11 Window Front (5L 17.4 0.370 NFRC 0_32 12 Window Front (5) 20.8 0.370 NFRC 0_32 13 14 _MrLdow_Emnt_(.S)_ Window Left (W) 40 39.6 0.370_NF_RC 0.32 0.370 NFRC 0_32 15 Window Left (W) 20.2 0.370 NFRC 0_32 16 Window Left (W_ 17.4 0.370 NFRC 0_32 17 Window Left (W) 22.2 0.370 NFRC 0_32 18 Window Left (W) 22.2 0.370 NFRC 0_32 12 _Window Rear (N)_ 27.5 0.3_70 NFRC 033 _NERC NFRC _9.0_ 90 -9.0_ Existing_I.W_ C_53D_0 VinylLLow_E 90 Existin _IWC 5300 Vinyl/Low-E _ExistingfLoor Existing Floor NFRC 90 90 Existin _IWC 5300 Vinyl/Low-E Existing Floor NFRC 90 90 Existing_IWC 5300 Vinyl/Low-E Existing Floor NFRC 90 90 Existing_IWC 5300 Vinyl/Low-E Existing Floor NFRC 90 90 Existin _IWC 5300 Vinyl/Low-E Existing Floor NFRC NFRC 9 90 90 Existing_1WC5300 v I/Low-E 90 Existing_IWC 5300 Vinyl/Low-E Exi-stina Floor Existing Floor NFRC NFRC NFRC 90 180 90 Existing IWC 5300 Vinyl/Low-E 90 Existing -IWC 5300 I/LQw-E 90 Existin _IWC 5300 Vinyl/Low-E Existing Floor Existing Floor Existing Floor NFRC 180 90 Existing_IWC 5300 Vinyl/Low-E Existin Floor -NERC. NFRC 1.8.0 270 90 Existing_IWC-5300 90 Existin VinyVLow=E _Exi.sting_Eloof _IWC 5300 Vinyl/Low-E Existing Floor NFRC 270 90 Existing_IWC 5300 Vinyl/Low-E Existing Floor NFRC 270 90 Existing IWC 5300 Vinyl/Low-E Existing Floor _NFRC 270 90 Existing_IWC 5300 Vinyl/Low-E Existin Floor NFRC 270 90 Existing_IWC 5300 Vinyl/Low-E Existing Floor NFRC 0 90 Existing_IWC 5300 Vinyl/Low-E Exi in Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Insulation R -Val. Location Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 Existing Floor Slab Perimeter 14 None No Insulation 26-A1 New 2 Bug Screen 0.76 5.0 3.0 10.0 0.1 10.0 10.0 3 Bug Screen 0.76 5.0 3.0 10.0 0.1 10.0 10.0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen. 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 7.0 2.0 10.0 0.1 10.0 10.0 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug,Screen 0.76 19 Bug Screen 0.76 8.0 6.0 13.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length Insulation R -Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 156 None No Insulation 26-A1 Existing Existing Floor Slab Perimeter 162 None No Insulation 26-A1 Existing Existing Floor Slab Perimeter 14 None No Insulation 26-A1 New Addition Run Initiation Time: 12109/06 18:10:14 Run Code: 1165716614 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Santa Rosa Cove Project Title ' 12/14/06 Date FENESTRATION SURFACES # Type Area U-Factorl SHGCZ True Cond. Azm. Tilt Stat.. Glazing Type Location/ Comments 20.-Wiadow-2eac(N) —174 _0_37-0 -NERC _0..32 21 Window Front (SW) 17.4 0.370 NFRC 0_32 _NERC NFRC 0_ _9-0_ Existing_LW_ 225 90 Existing _C_5 -3-0D Vinyl/.Low_E _IWC 5300 Vinyl/Low-E -Existing-FJn^r Existing Floor 22 Window Rear (1 17.4 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E Addition 23 Window Rear (N)_ 48.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E Addition 24 Window Rear (NL 17.4 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type • SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location Condition Location/ JA IV Reference Status Comments Run Initiation Time: 12/09/06 18:10:14 Run Code: 1165716614 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:5 of 11 Certificate Of Compliance : Residential (Part 3 of -4) CF -1 R Santa Rosa Cove 12/14/06 Project Title Date HVAC SYSTEMS Duct Duct Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Existing FAU & A/C Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Existing Setback 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts Vand 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. , Designer or Owner (per Busi s & Professions Code) Documentation Author Name: Name: Title/Firm: Rebaca Denni Title/Firm: Luz Fregoso Address: P.O. Box 51 F V Address: 44525 Avenue Portola La Quinta, JA 92248 Palm Desert, CA 92260 Telephone: 760 578 9855 Telephone: _ 7( 60) 837-9009 Lic. #: (signature) (date) eignret) date) Enforcement Age/y Name: Title/Firm: Address: Telephone: HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Existing FAU & A/C Ducted Ducted Attic 4.2 Existing No . Hydronic Piping Pipe Pipe . Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status br RE' (%) Ext. Standard Gas 50 gal or Less Small Gas Kitchen Pipe Ins 1 40,000 50 Existing 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Pi 'Ing Length_ Add 1/2" Control # HP TVDe In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts Vand 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. , Designer or Owner (per Busi s & Professions Code) Documentation Author Name: Name: Title/Firm: Rebaca Denni Title/Firm: Luz Fregoso Address: P.O. Box 51 F V Address: 44525 Avenue Portola La Quinta, JA 92248 Palm Desert, CA 92260 Telephone: 760 578 9855 Telephone: _ 7( 60) 837-9009 Lic. #: (signature) (date) eignret) date) Enforcement Age/y Name: Title/Firm: Address: Telephone: Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Santa Rosa Cove 12/14/06 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified In this checklist. These Items require special written justification and. documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The Roof "Default Roof Prior 1978 to Present' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manua . The Existing Water Heater "Standard Gas 50 qal or Less" has an EF less than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan Field installation certificate. EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Paae:7 of 11 Mandatory Measures Summary: Residential (Page 1 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether .� they are shown elsewhere in the documents or on this checklist only. e DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 191",y 0 .. § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ . ❑X ❑ apply to exterior mass walls). ❑ 1:1 El �§ 150(d): Minimum R-13 raised Floor insulation in framed floors or equivalent U -factor. ❑ ❑X ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. , 1. Masonry.and factory -built fireplaces have.: ❑ ❑X ,.. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and, control - ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑" ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ 1:1 El § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater,than 0.3%, water vapor ❑ ❑ ❑ '. permeance rate no greater than 2.0 perm/inch. , § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include rt ❑ ❑ CF -6R Form: 110-13: ❑ ❑X ❑ § 116-17' Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑X ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. x ❑ ❑X ` El. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain r Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors'end windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ easures'- ,Space Conditioning, Water Heating and Plumbing System Measures'- ❑', ❑ ❑ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ~ ❑ _ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. r 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater... 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑', ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table,150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2' by EnergySoft User Number: 5982 Job Number: L1024 Page: B of 11 Mandatory Measures Summary: Residential (Page 2 of 2) W-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. N/A ENFORCE - DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans ❑ © ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of ❑ ❑ ❑ luminaire has factory installed HID ballast. R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.❑ X❑ ❑ or tape shall be used. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ X ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ © ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1'19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 "or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page:9 of 11 Residential Kitchen Lighting. Worksheet WS -5R Santa Rosa Cove 12/21/06 ' Project Title Date At least 50% of the total rated wattage of permanently installed luminaires In kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 26w Compact Fluorescent Quad 2 Pin Yes X No 27.0 x' 11 = 297 or Yes No x or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes / No x = or Yes No x = or :Yes No x = or Yes .. No Yes No x = or, Yes No X _ or Yes No X _ or Yes No x = • or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 297 B: +' 0 COMPLIES IF A Z B YES RNO ❑ 13 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Page•10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Santa Rosa Cove 12/14/06 SYSTEM NAME FLOOR AREA Existing FAU & A/C 2,292 Number of Systems 1 Heating System Output per System 120,000 Total Output (Btuh) 120,000 Output (Btuh/sqft) 52.4 Cooling System. Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuhlsgft) 25.7 Total Output (sgft/Ton) 466.2 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sqft) 0.44 Airflow (cfm/Ton) 203.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensible Latent CFM I Sensible 1,462 38,903 -784 L±1685 49,854 0 6,049 6,396 0 0 0 0 0 0 0 0 0 6,049 6,396 51,001777;;4 62 646 Existing Furnace & Air Conditioner 50,787 1,397 120,000 Total Adjusted System Output 50,787 1,397 120,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.0 of 69.0 of 65.0 of 0.. Supply Air Ducts Outside Air 0 cfm 59.0 of Supply Fan Heating Coil 1000 cfm ROOMS 69.0 of 75.0 °F h Return Air Ducts 'I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0/72.5OF 85.7/64.1OF 85.7/64.1OF 55.0/53.2OF O Supply Air Ducts -Outside Air 0 cfm Supply Fan Cooling Coil 60.7 / 55.5 of 1000 cfm 36.5% R.H. ROOMS 85.7 / 64.1 of 80.0 / 62.2 of h Return Air Ducts 4 EnergyPro 4.2 by EnergySoft User Number: 5982 Job Number: L1024 Paae:11 of 11