Loading...
0304-145 (SFD)H C%4 t) O M W oZ � O O W W m �a U) Z C7 L0 N ON U °) 11. Q Z �a0 0 J J mU U O rnH ,Itz ob O Q J LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force Ind effect. License # ' Lic. Class F/ Exp. Date X 51Ft [ j f 1(113 U� JD tae 'i I�. Signature of Contractogr OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am -exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION, I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier MEAPT Policy No. (This section need not be completed if the pell4mit valuation is for $100.00 or less). () I certify that in the performance of the,work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject t��/the wdrkers' compensation provisions of Section 3700 of the Labor Coded shall,forthwith comply with those trro�isions. Warning: Failure to secure Workers''Compehsation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced withiry 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with'all City, -"and State laws relating to the building construction, and hereby authori�,e representatives of this City tot enters upon the above-mentioned property for 'nspection purposes. ­ I / Signature (Owner/Agent) -�'�•- .` Date BUILDING PERMIT PERMI0304 45 DATE -7r -JA � VALUATION , �it!:MV, LOT ) 5 TRACT :11%4110_ iJOB SITE 661 DEAN1'IIVE ADDRESS 9: CO��. APN 769 - toil •Q.)1 OWNER CONTRACTOR / DESIGNER / EN (NEER Wcyrs"�?y'�itpy C�{�1�,17�px�.�rA. r r�r 'a iLS i:#IL �,? S C01d>� a? A*n0c 1 y TZ�- y l S ,,700 �7.1L�LC`RL'NS� D3R. *15, r OBOX 11235 . ix 't 57. y( PJ 11 t1.'. i:T CA 92261 (703)34fi,5Cr, Cr�ufi 3333 USE OF^ �PERMIT ((��j .2A.Lq! ..5.><,1� 1''.�:�'� b��4'.I<',�.•�.Q.iv�,7 YP'.KMI I L3Oi: ZI &1V P i t.LU.1LP:.•fii �:�rsTab17 �:r.��r�f°F.i�r��lt7� �;a•a�.oa �c W, RAMCATTO RT 7 PiUii sr? E':n. TT) rV&C OF C ON5 71'w KITION F'.I r<", ; -000"l 1 p -M 0 PLA4lCV,,•>s"'l:FEE tOk_G00'^'C.4C-318 �1,0PYb.44 F'1:1; 1 i1'1-t1CW01•11 :t9-31 e -Sie o-tv ' 101 -(XVI- A:41 -'130r. $lSb.50 I;1..:.f�:"1'11`7?:;tsirl��,� 1111�n��t��1f`�Ct-�1Ly x:i1b.62 r,LU$4VBa.:0 F'i+..� 101 _0Ci-1-f_i :9-L?J. .;'Sx:.O fax MOTION - ttllSM 310; 0(0t '4' 1.-CeM' S28,95 p ORADIIN 9 ` 11? 101-000-12,S-000 TPViF'ACIT II;e: 3; iU4.4�t .r�i?7` f� �'F_+�1„1t,: 6+I.F'�ir1r..1:: • :�ft�i� 2�4y-t?4S^!,:!";,5•G'tii�1 �32:�.17 1?3 F' �°CZ 9`P3, ��iAt� '1':3; ►1'C� : CI� t t' AM d'liw, UrV;C41 S ),w,.98 U111011 FRE-MIDRIM"': ?4,2.J0.00 P/( /Llt d 'r'•11 rT.p ti; ,t F.M.'s&�.���i� ci J _7 4, JUL 2 3 2003 �y CITYLA RECEIPT "'••• L -' 'DANE BY D E FINALED INSPECT INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel v Combustion Air Roof Deck Q Exhaust Fans O.K to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS steel .Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric :Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection — ' Q Encapsulation Gas Piping Gas Test -� Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final _ Utility Notice (Perm) CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 7/15/03 La Quinta, CA 92253 No. 24710 (760) 771-8515 Owner Brittany Capital Corp APN # Address 12700 Hillcrest Dr. #15 Jurisdiction City Dallas, TX Zip 75230 Permit # Tract # 28740-1 Study Area Type Single Family Residence No. of Units Lot # Unit 1 16 Unit 2 Unit 3 Unit 4 Unit 5 Comments No. Street S.F. 78661 Deacon Drive East 3444 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. 4���FIEDSc�o Q BERMUDA DUNES h En RANCHO MIRAGE t� {� INDIAN WELLS d•�PALM DESERT y LA QUINTA �%IN0 y� O 769-180-021 La Quinta 1 Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/Walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 3,444 S.F. or $7,370.16 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Canyon National Bank - Curt Dunham Check No. 15147 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon McGilvrey 0- n i e . < Signature C' Payment Recd $7,370.16 So.00 Over/Under NOTICE: Pursuant to Government Code Section 66020(d)(I),%q!sYiflserve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on Which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting 05/27/2003 08:28 7603469918 DRM rant n�in� Tradition Mr, and Mrs. Bob Clements May 27, 2003 C/o Brittany Capital Company, Inc. 12700 'Hillcrest Road, Suite 150 Dallas, TX 75230 Re: 78661 Deacon Drive East Bear 1, ir, and Mrs. Clements, The Tradition Architectural Committee has reviewed your second sutl)mittal of construction drawings for your home on Deacon Drive East. The plans were 4proved subject to the following comments: 1. On the grading and drainage plan, you will need. to show the actual mvised contours not just lines with plus numbers indicating fill areas. This :elan must show existing and proposed final contours. 2. On the electrical plan, the Werior fixtures on the side yards must Jure concealed filaments. The fixtures submitted show exposed filamews, Please submit a different fixture for the side yards, 3. Please subinit hardscape materials, finish and colors when chosen. 4. The f'rorit y" lighting must be noted to be photocell. on/off The re mai;nder of the lighting may be switched at the owzrers discrection. 5. The -palm tree shown in the rear view triangle to the east of the MCI area will need to be removed. 6. The palm will need to be moved to the west of the spa toward the h: ruse to be placed between the house and spa and out of the view triangle. 7. Please delete the reference to gravel being placed on planters with,izi the front yard. This requirement has been elirninated. 8. A $5,000.00 construction performance deposit is required prior to tl:Ie onset of construction. Please make this check payable to: Traditi+7n Community Association. The Association approves construction to begin once the construction perfom],Vace deposit is received. The'other items will need to be addressed prior Ito the setback inspection for this home. Thank you for your submittal and patience: in our review of the material. Sincemly, The Tradition Architectural Committee Tradition Community .,U- sociaation cc: BBG Architects Randy ;Purnell DESERT RESORT MANAGEMENT POST OFFICE BOX 4772 - PALM DESERT, CALIFORNIA 92261-47-1-2 73-�50 ALESSANDRO, SUITE S • PA -UA DESERT, CALIFORNIA 92240 NONE (760) 346.1161 4 FAX (760) 346.9918 m ESI/FME, Inc. Sheet 16 STRUCTURAL ENGINEERS Date 6-02-03 JN. 303-3575 ' TRADITION -LOT 16 / BRITTANY CAPITOL LA QUI NTA, CA h N. O C� t4 - / r�._ ~ C , ' V / cc a) Ulu Qi o 0), Z +r � m CV 'N LL:D reA 6-r B r� , FE 'ol q / CID / ro VIL or / U) , / 1 0"/ va ,_/� nn_ N� CITY OF LA QUINTA SUB -CONTRACTOR _LIST ► n _JOB ADDRESS �PI `meq PERMIT NUMBER OWNER BUILDER' N�1 �y I 1d�..c This orm shall be posted on the lob with the Building Inspection Card at all times in w -! 0,,;y pws s appearing on this list or their employees are authorized to work on this inh e�� ��_ ;c ;;,x� m�,L ua approves by the Building Division prior to commencement of work. Failu a to comply will result in •a stoppage of work and/or the voidance of building ermit. For each applicable trade, all information 'requested below must be completed by applicant. `On File' is not an acceptable response. 'Trade ! Classification Contactor'-'=' State Contractor's License CONCRETE (C-81 C�C! Workers Com ensatJori'Irisinariee Clt Business _ Company Name Clsssl(icadon License Number Exp. Date Carrier Name Policy Number 1 Number DRYWALL (C-9) L , (e.g.A. 8. C-81 Ixxxxxxl Ix I 1xx) (e.p. State Fund. CalComp) (Format Varies) MExp.DateUcense (xxxx) QFxp.0sts EARTHWORK (C-12) o _ GLAZING IC-17)t^n 9 03 kpo / mt,caL r,.. , O 73 Z- CONCRETE (C-81 C�C! FRAMING (C-5) e 0- �-A R M r ^Al STRUCT. STEEL (C-51) 5adIOoc JL UJ -el 1r„C1 MASONRY IC -29) PLUMBING (C-36) 1 LATH. PLASTER (C-35) DRYWALL (C-9) L , HVAC IC -201 aA ELECTRICAL (C-101 ROOFING (C-39) SHEET METAL (C-431 Wt FLOORING (C-151 W GLAZING IC-17)t^n VI INSULATION (C-2) r,.. , SEWAGE DISP. (C-42) PAINTING (C-331 w N CERAMIC TILE (C-64) CABINETS IC -e) FENCING (C-131 LANDSCAPING (C-27) POOL (C-53) /l ( W4ift, eci A,\1 1 c,- 000* cl—VI C, 3 ��L —24 n c-35 —� 3 �-'-' MM -Z Z21�( U-33 �f S9�zy �0-7 I ZN/ (.),- (", z-90 oo)e,03 -TZ per_ /L770o0o /t,/ Y i o O ,/62- O -Z, ozOZ, 6 2 V 03 4 Sr!STi� 19�e10 I O��Z3 ►e_T O/LSC ao3L cod YS p 2S M�� I FA P.J. VI :Ili I �..� •.: .. ' • - 1 A •� • VI • r,.. , NI I Mo ?.,t on-, m, lkwoPi V a � (", z-90 oo)e,03 -TZ per_ /L770o0o /t,/ Y i o O ,/62- O -Z, ozOZ, 6 2 V 03 4 Sr!STi� 19�e10 I O��Z3 ►e_T O/LSC ao3L cod YS p 2S M�� Apr O1 03 12:52p sladden palm desert 760772 3895 p.1 t. SLADDEN ENGINEERING (760) 772-3893 (760) 77273895 FAX FACSIMILE TRANSMITTAL SHEET" FROM: /�,>✓ �'rc,✓ ' L • ti Brett Anderson/jo-. 1✓ . 5�� COMPANY: DATE: y- /- 03 FAX NUMBER: TOTAL NO. OP PAGL-'S INCLUDING CUVGR: 7/y 63:5-28/' y PHONE NUMBER: SENDER'S REVS -11E" -NCC Nuwra: -71y 83.5-2800 `. RL•: YOUR I(F.FI RENCE NUMUL•R: . ❑ URGENT ❑ FOR RLV[rW ❑ PLEA$13 COD4MENl' ❑ PLLASG REPLY ❑ PLL'A$i: Il1'(C1'CL1; rt / 7�" 9-7 w� 39-725 GARAND LANE, SUITE C PALM DESERT, CALIFORNIA 92211 Apr 01 03 12:52p sladden palm desert 760 772 3895 p.2 Ref: I. Report of Observations and Testing During Rough Grading prepared by Sladden Engineering dated July 30, 1997, Project No. 522-6138-G 1. 2. Geotechnical Update prepared by Sladden Engineering dated December 12, 1996, Project No. 544-6130. As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed single-family residence. The project site is located on Lot 33 gl'Tract 28420-1. along Peerless Place within the Tradition Golf Club development in the City of La Quinta, California. It is our Understanding that the proposed residence will be a relatively lightweight wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previoutily graded during the rough grading of the Tradition project site. The rough grading included overexcavation of the native surface soils along with the placement of engineered f ll. material to .construct the building pad and adjacent lots... The site grading is summarized in the referenced Report of Observations and Testing During Rough Grading along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the . structural values included in the referenced grading report remain applicable for the design and construction of the proposed residential structure foundations. o Because the lot has been previously rough graded, the remedial grading required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Apr 01 03 12:53p sladden palm desert 760 772 3895 p.3 Allowable Bearing Pressures: The allowable bearing pressures recommended in the referenced grading report remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a, minimum of 12 Inches below lowest adjacent grade. Continuous footings should be at least. 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad foutings should be designed utilizing allowable bearing pressures of 1500 psf. An allowable increase of 200 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable foundation bearing pressures may be increased by one-third when considering wind and seismic loading. The bearing soils are non -expansive and Kali within the "very low" expansion category in . accordance with Uniform Building Code (UBC). classification criteria. Pertinent 1997 U13C Seismic Design parameters are summarized on theattached data sheet. If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respcetfully submirted, SLADnrN ENGINEERING Brett l,. Anderson Principal Engineer SER/pc RPr 01 03 12:53p sladden Palm desert 760 772 3895 P.4 1997 UNIFORM BUILDING CODE rNFORMATION The Intcrnational Conference of Building Officials 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16. Concepts contained in the code that will likely be relevant to construction of the proposed structures are sunrnnarized-below. Ground shaking is expected to.bc the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating large earthquakes. Maj01- fault zones considered to be most likely to create strong ground shaking at the site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 UBC San Andreas 13 km A San Jacinto 30 km A Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is So; generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. Sladden Engineering Near -Source Near -Source Seismic Seisinic . Seismic Acceleration Velocity Coefficient Coefficient Source Factor, Na Factor, N,. C, C„ San Andreas 1.0 1.1 0.44 N, 0.64 N,. San Jacinto 1.0 1.0 0.44 N;, j 0.64 N� Sladden Engineering Mc GEE SUR VEYING, INC. 79-301 Country Club Dr., Ste. 102 — Bermuda Dunes, CA 92201 Phone (760) 345-3828 — Fax (760) 772-5705 August 1, 2003 City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Re: Pad Certification — Lot 16, Tr. 28470-1 Pursuant to your request a field survey was conducted on the above referenced project to determine the vertical location of the building pad. The above mentioned was found as follows: LOT ADDRESS PAD (DES) PAD (FIELD) 16 78-661 Deacon Dr. East 38.0' 38.0' A. Sincerely, LS SM 30 !i 4 - Wayne A. McGee L.S. 5479 ESI/FM E,Inc. STRUCTURAL ENGINEERS & CONSULTANTS FIELD REPORT -79�)C. / >> , SITE VISIT NO.: O N E PROJECT: "TRADITION - LOT 16" BUILDER .: BRITTANY CAPITAL CO. LOCATION: La Quinta, California ARCHITECT:- BBG ARCHITECTS ATTENTION: Kirk Durham with Easton Builders DATE Dec. 04, 2003 PROJECT NO 203-3575 CLIENT NO: BBG r FILE NO 3575FR1 SHEET NO : 1 OF 4 PROJECT SUMMARY SITE -Single Family house is situated in a semi -developed area. Field Observation on Dec. 2, 2003 with Chuck from Tandem West FIELD OBSERVATION The following structural items were observed and need to be addressed: For location .and clarification of items, refer to photo reduction of framing plan on following sheet. ITEM General 1 Provide. 5/8" dia threaded rod with. Simpson Set Epoxy Tie embedded 4 1/4" into foundation for missing anchor bolts or 5/8" dia. Kwik bolts with min. 2 374" edge distance from edge of slab. Garage and Service Room: 2 Shear panel at left side of Garage: Add shear panel #11 on inside where electrical panel eliminated shear panel. 3 Shear wall at rear of garage: Provide shear transfer per Detail R-4/SD1. 4 Right side of Garage: Add Simpson H1 to end of drag truss at two locations. Refer to reduced framing plan on following sheet for location. 5 Roof Break over Garage: Provide Simpson A35's @ 48" o.c. from top chord of truss to 2x ledger at lower roof. 6 Right side of Golf Garage: Provide CS16 strap per Detail C1/SD2. 7 Left side of Service Room: Add Simpson A35F each side of header to post at one end, due to trimmer not extending -to foundation. Entrv,Living Room, Dining Room, Nook,Loggia, and Kitchen: 8 Over Kit: Provide plywood ceiling after inspection., 9 Hardy Panels at rear of Dining Rm: Add (4) Simpson LTP4 from solid block to beam above on each side [total (8) LTP4's] on each hardy panel. 1800 E. 16th Street, Santa Ana, CA 92701 (714) 835-2800 Fax (714)'835-2819 E.SI/FME,Inc. STRUCTURAL ENGINEERS & CONSULTANTS FIELD REPORT PROJECT: "TRADITION - LOT 16" DATE. Dec. 04, 2003 BUILDER BRITTANY CAPITAL CO. PROJECT NO 203-3575 LOCATION: La Quinta, California SHEET NO : 2 OF 4 10 Over Kit: Provide holdown straps per Detail X1.b/SD2 11 Front of Kit and Entry at High Roof: Provide shear blocks at 48" o.c per Detail Q1/DS2 along the inside wall. 12 Shear wall at left side of Loggia: Add Simpson ST6224 from post to beam per Detail L /SD1. 1.3 Front of Entry Porch: Add two more Simpson A35's to block with strap from Golf Cart Gai MBR, MBA, BR#3, Casita, and BR#2 14 Over MBR: Add Simpson MST48 from beam to drag truss per Detail Y1/SD2. 15 Wall at rear of MBA shower: Add Simpson A35's at 8" o.c. over wall per Detail R-4/SD1. 16 Hip Truss over MBR: Provide hanger for hip truss. 17 Shear wall at rear MBA: Provide Simpson A35's at 8" o.c. per R-4/SD1. 18' Over BR#3 & MBA: Provide straps per Detai D1/SD2 at lower roof to wall. 19 Right of Casita Bathroom: Add Simpson A35F from header to king post on each side at one end, due to trimmer not extending to foundation. 20 ' Shear wall at right side of BR#2 Bathroom: Add Simpson HTT16. 21 Shear wall in front of Casita: Add (2) 10d nails every foot along the panel edges and boundary, since 8d nails were used in lieu 10d common nails. 22 Drag Truss in Front of Casita: Provide Simpson H7 from wall to drag truss. 23 Entry into Casita: Provide Simpson H2.5 or ST22 from drag truss to wall at each end. DISCLAIMER: THIS WAS A WALK-THRU REVIEW. WE DID NOT INSPECT THIS BUILDING. OUR OBSERVATION WAS ONLY FOR OBVIOUS PLAN OMISSION. A DETAILED AND COMPLETE REVIEW WAS NOT PERFORMED. ISSUED B gFESS� �ti� ESI / F d COPIES TO: STRU '� T S (3) EASTON BUILDERS BY: �Q z (fax) Attn: Kirk Durham P. (1) BBG ARCHITECTS Attn: Anton Marinkovich Danny _ P Street, . Santa Ana, CA 92701 • (714) 835-2800 • Fax (714) 835-2819 TRADITIO=- LA QUINTA, CA ESI/FME, in.c. STRUCTURAL ENGINEERS 3RITTANY CAPITAL CO. Sheet Date 12 -04 - JN. - 303-35 ....... .... . ...... ... 77 f 6