12-0548 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
12-00000548
Property Address:
52820 DEL GATO DR
APN:
770-330-050- - -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
27877
Td�/ 4 4v Q"
Applicant: Architect or Engineer:
(tea->�.*►w�- �
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am li ed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business role sionals Code, and my License is in full force and effect.
License Class:13License No.: 91
�DatP 2' 7 / ntractor:
IVTTT^^ OERZUILDEVDECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by .
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
(_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of, completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). '
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 7/12/12
Owner: .
HOLLMAN,ROBERT R & JOAN
D lj
Contractor:
SUN VISTA DEVELOPMENT
CITY
COttr=w6ma
P.O. BOX 1144
LA QUINTA; CA 92247
(760)771-4722
Lic. No.: 744091
-----------------------'------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0000179-2011
I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any
person in any manner so as to become sub•ect to the workers' compensation laws of California,
and agree that • u beco a subje t the workers' compensation provisions of Section
3700 of abor C , I s all forth th mply with those provisions.
*-t!& Applican
WARNING: FAILURE TO SERE WOR RS' COEl SATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTI /SAND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
'of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such per ' cessation of work for 180 days will subject
permit to cancellation.
certify that I have read this application and state that a above infor t' n' agree to comply with all
city and county ordinances and state laws relating building constru i , nd hereby authorize representatives
of this county to enter upon the above-mentione roper or insp i n pu oses.
t / Si nature (Applicant or A Intl:
r . -
Application Number .
. . . . 12-00000548
------ Structure Information
345SF ADDITION/VB/RES-3/CLASS A -FR
[ENG] -----
Other struct info . .
. . . CODE EDITION 2010
FLOOD ZONE no
-----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
345.00
Permit . . .
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
271.50 Plan Check Fee
176.48
Issue Date ' . . . .
Valuation . . . .
27877
Expiration Date
1/08/13
Qty Unit Charge
Per
Extension
BASE FEE
252.00
3.00 6.5000
------------------------------------------------------
THOU BLDG 25,001-50,000
-------------
19.50
---------
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
27.08 Plan Check Fee
6.77
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
1/08/13
Qty Unit Charge
Per -
Extension
BASE FEE
15.00
345.00 .0350
----------------------------------------------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
12.08
Permit . . . MECHANICAL
Additional desc .
Permit Fee . .
19.50 Plan Check Fee
4.88
Issue Date
Valuation . . . .
0
Expiration Date .
1/08/13
Qty Unit.Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
--------------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
--------------
4.50
Permit . . .
PLUMBING
Additional desc . .
Permit Fee . . . .
30.00 Plan Check Fee
7.50
Issue Date . . . .
Valuation . . . .
0
Expiration Date
1/08/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
LQPERMIT
Application Number . . . . . 12-00000548
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
2.00 6.0000 EA PLB ROOF DRAIN
12.00
1.00 3.0000 EA PLB GAS PIPE 1-4
OUTLETS
3.00
------------------------------------------------------------
Special Notes and Comments
---------------
345SF PARLOR ADDITION/VB/RES-3/CLASS
A -FR (ENGINEERED] 2010 CALIFORNIA
BUILDING CODES.
July 10, .2012 2:56:39 PM AORTEGA
-
-------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS. ADMIN (SB1473).
--------------
2.00
ENERGY REVIEW
FEE
17.65
STRONG MOTION
(SMI) - RES
2.79
Fee summary Charged Paid Credited
---------------------------
Due
--------------------
Permit Fee Total 348.08 .00
----------
.00
348.08
Plan Check Total 195.63 .00
.00
195.63
Other Fee Total 22.44 .00
.00
22.44
Grand Total 566.15 .00
.00
566.15
LQPERMIT
.ts��. aGrx- -5/31
IA
lot
CItj/ Of 1%a Quihta
Building ai Safety Division
P.O. Box 1504,•78-495 Calle Tampico
La..Quinta, CA 92253 -(760)777-7012
Building Pennit Application, and Tracking Sheet
Permit # 1I11..
l�K
Project Address: -{p "
Owna's Name:.
A. P. Number:
n - /
Addtoss: 5 - 8� Amit &4A LL
Add
Legal Description:
City, ST, Zip:
Contractor
Telephone:
Address:
Project Description:
City, ST, Zip:
L�.S
Telephone:
o
State Lia #:
City Lic. #;
Arcfi., Engr., Designer
Address:
City., ST, Zip:
Telephone:
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
State Lia #: R
Name of Contact Person:Sq.
Ft.:
# Stories:
#Unit$:
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Recd
TRACIMG PERMrrFEES
Plan Sets
Plan Check submittedj/(� Item Amount
Structural COke.
Reviewed, ready for corrections Plan Check Deposit. .
Truss Cates.
Called Contact Person V Plan Check Balance. � � •
Moe 24 Cal&
Plane picked up Construction
Flood plain plan
Pians resubmitted.. 20 Mechanical
Giading plan
Z`! Review, ready for correction `_ Electrical
Subeontactor List
Called Contact Person 1 Plumbing "
Grant Deed
Plans picked up &IVLL
H.O.A. Approval
Plaus resubmitted Grading
IN HOUSE:-
''" Review; ready for eorrecdonslissuc Developer Impact Fee
Planning Approval.
Called Contact Person AXP.P.
Pub. Wks. Appr "
Date of permit issue
School Fees
Total Permit Fees
.ts��. aGrx- -5/31
IA
lot
CERTIFICATE OF COMPLIANCE Desert Sands Unified School Districtz4r—'11117ib)
47950 Dune Palms Road Q BERMUDA DUNES r
to RANCHO MIRAGE d
Date 8/7/12 La Quinta, CA 92253 INDIAN WELLS
PALMDESERT
No. 31351 (760) 771-8515 9> LA OUINTA �y
QIN0 y�
0
Owner Hollman
APN # 770-33-050
Address 52820 Del Gato Drive
Jurisdiction La Quinta
City La Quinta Zip
Permit #
Tract #
No. of Units 1
Type Residential Addition
Lot # * No. Street
S.F.
Lot # No. Street S.F.
Unit 1 52820 Del Gato Drive
345 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 345 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Rob Capetz Check No.
Name on the check Telephone
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected
Signature
Payment Recd
$0.00
Over/Unshr
NOTICE: Pursuant to Government Code Section 66020(d)(1)\'4Jis will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
Tradition
June 30, 2012
Mr. and Mrs. Hollman
52840 Del Gato Drive
La Quinta, CA 92253
8a0
Re: Hollman/Lot 54, Tract 28867 at 52840 Del Gato Drive
Remodel: Room Addition/Paint Modification #2
Dear Mr. and Mrs. Hollman,
The Tradition Architectural Design Review Committee (ARRC) reviewed your revised remodel
plans for your home on Del Gato Drive. All previous review items were completed and the
project is approved to start construction.
Please contact Brook Marshall at (760) 219-8057 or by email at with any
questions or to schedule your Pre -Construction Meeting at the lot.
Sincerely,
Tradition Architectural Design Review Committee
CC: Sun Vista
Carol Whiltlock
Tradition Security
ARRC File
DESERT RESORT MANAGEMENT
POST OFFICE BOX 14387 • PALM DESERT, CALIFORNIA 92255-4387
42-635 MELANIE PLACE, SUITE 103 • PALM DESERT, CALIFORNIA 92211
TELEPHONE (760) 346-1161 • FAx (760) 346-9918
BUILDING ENERGY ANALYSIS REPORT
I
PROJECT:..
Traditions Residence
' Lot # 54, The Traditions
La Quinta, CA 92253
Project Designer:
Helton, DeFord & Associates
1261 N. Big Spring Street
Anaheim, Ca 92807
(909) 957-4550
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(7.60) 200-4780
CZIVic-iiD
JUN 21 2012
BY:
Job Number:
Date:
6/8/2012
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
FOR CONSTRUCTION
DATEBY
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2112-06-08711:52:24 10:
w
A&
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 12
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712
i
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
Project Address
Lot # 54, The Traditions La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,315
Addition
345
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A,CF-4R must be provided per Part 2 of 5 of this form.
IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity ft-) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-19 3,970 Existing
Wall Wood Framed R-11 4,304 Existing
Door Opaque Door None 22 Existing
Slab Unheated Slab -on -Grade None 3,970 Perim = 430' Existing
Roof Wood Framed Attic R-38 362 Radiant Barrier New
Wall Wood Framed R-21 216 New
Slab Unheated Slab -on -Grade None 398 Perim = 22' New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Right (N) 264.0 0.790 0.59 none none Bug Screen Existing
Front (E) 191.6 0.790 0.59 none none Bug Screen Existing
Left (S) 259.4 0.790 0.59 none none Bug Screen Existing
Rear (lM 329.0 0.790 0.59 none none Bug Screen Existing
Skylight 36.0 0.800 0.39 none none None New
Right (N) 48.0 0.550 0.55 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
5 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
City. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06.08711:52:24 ID:
Page 3 of 14
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Traditions Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof(R.38.2x 14.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix R44.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ene Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-06-08711:52:24 ID: Page 4 of 14
•
•
PERFORMANCE CERTIFICATE: Residential Part 3 -of 5) CF -1 R
Project Name
Building Type' m Single Family ❑ Addition Alone
Date
Traditions Residence
❑ Multi Family m Existing+ Addition/Alteration
6/8/2012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 14.33 12.24 2.09
Space Cooling 164.22 152.02 12.20
Fans 35.92 33.15 2.76
Domestic Hot Water 9.98 9.98 0.00
Pumps 0.00 0.00 0.00
Totals 224.45 207.39 17.05
Percent Better Than Standard: 7.6%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 1,297 92
Fuel Available at Site: Natural Gas (S) 1,320 259
Raised Floor Area: 0 (vv) 1,381 313
Slab on Grade Area: 4,368 (N) 1,420 212
Average Ceiling Height: 12.0 Roof 4,368 36
Fenestration Average U -Factor: 0.78 TOTAL: 912
Average SHGC: 0.59 Fenestration/CFA Ratio: 21.12
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
/2012
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Si ned Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Helton, DeFord & Associates
Address 1261 N. Big Spring Street Name Dave Helton
City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License# Date
EnerqvPro 5.1 by EnerqvSoft User Number. 6712 Run Code: 2012-06-08711:52:24 /D: Page 5 of 14
•
•
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation Joint Appendix
Factor CavitYTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
3,970
0.049 R-19
0
20 Existing4.2.1-A4
ExistingResidence
Wall
1,076
0.110 R-11
0
90 Existing4.3.1-A2
ExistingResidence
Wall
221
0.110 R-11
0
90 Removec 4.3.1-A2
Existing Residence
Wall
1,183
0.110 R-11
90
90 Existing 4.3.1-A2
Existing Residence
Door
22
0.500 None
90
90 Existing 4.5.1-A4
Existing Residence
Wall
234
0.110 R-11
90
90 R6movec 4.3.1-A2
Existing Residence
Wall
1,061
0.110 R-11
180
90 Existing 4.3.1-A2
Existing Residence
Wall
984
0.110 R-11
270
90 Existing 4.3.1-A2
Existing Residence
Wall
240
0.110 R-11
270
90 Removec 4.3.1-A2
Existing Residence
Slab
3,970
0.730 None
01
180 Existing 4.4.7-A1
Existing Residence
Roof
362
0.026 R-38
0
20 New 4.2.1-A9
Addition
Wall
132
0.069 R-21
0
90 New 4.3.1-A6
Addition
Wall
84
0.069 R-21
270
90 New 4.3.1-A6
Addition
Slab
398
0.730 None
0
180 New 4.4.7-A1
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGCz
Azm . Status
Glazing Type
Location/Comments
1
Window
15.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
2
Window
15.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
3
Window
15.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
4
Window
5.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
5
Window
5.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
6
Window
5.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
7
Window
8.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
8
Window.
8.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
9
Window
20.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
10
Window
40.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
11
Window
20.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
12
Window
8.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted,
Existing Residence
13
Window
40.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
14
Window
20.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
15
Window
20.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
16
Window
5.0 0.790 Default
0.59 Default 0 Existing
Double Metal Tinted
Existing Residence
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin
Len H t . LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
leug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number: 6712
RunCode: 2012-06-08711:52:24 ID:
Page 6 of 14
•
•
:7
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 -IR
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
OPAQUE SURFACE DETAILS
Surface Ll- Insulation Joint Appendix
Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
T e Area
LI -Factor
SHGC Azm Status Glazing Type
Location/Comments
17
Window 5.0
0.790 Default
0.59 Default
0 Existing Double Metal Tinted
Existing Residence
18
Window 5.0
0.790 Default
0.59 Default
0 Existing Double Metal Tinted
Existing Residence
19
Window 5.0
0.790 Default
0.59 Default
0 Existing Double Metal Tinted
Existing Residence
20
Window 13.8
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
21
Window 13.8
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
22
Window 8.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
23
Window 24.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
24
Window 8.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
25
Window 8.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
26
Window 8.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
27
Window 8.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
28
Window 20.0
0.790 Default
0.59 Default
90 Existing 'Double Metal Tinted
Existing Residence
29
Window 40.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
30
Window 20.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
31
Window 5.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
ExistingResidence
32
Window 5.0
0.790 Default
0.59 Default
90 Existing Double Metal Tinted
Existing Residence
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd Len
Ove hanq Left Fin Ri ht Fin
I H t LExt RExt Dist I Len H t Dist Len Hat
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bu Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
FEne-rgyPro
5.1 by EnemySoft
User Number. 6712 RunCode: 2012-06-08T11:52:24 ID:
Page 7 of 14
•
•
•
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC Azm Status Glazing Type
Location/Comments
33
Window . 5.0
0.790 Default
0.59 Default 90 Existing Double Metal Tinted
Existing Residence
34
Window 5.0
0.790 Default
0.59 Default 90 Existing 'Double Metal Tinted
Existing Residence
35
Window 40.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
36
Window 18.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
37
Window 22.4 .0.790
Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
38
Window 8.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
39
Window 48.0
0.790 Default
0.59 Default 180 'Exisiing Double Metal Tinted
Existing Residence
40
Window 3.5
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
41
Window 10.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
42
Window 10.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
43
Window 10.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
44
Window 3.5
0.790 Default
0.59 Default 180 Existing Double Metal Tinted _
Existing Residence
45
Window 8.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
46
Window 8.0
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
47
Window 11.01
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
48
Window 11.01
0.790 Default
0.59 Default 180 Existing Double Metal Tinted
Existing Residence
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window Cive hanq Left Fin
H tWd Len H t LExt RExt Dist Len
Ri ht in
H t Dist Len H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Bug Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
JBug Screen
0.76
48
IBug Screen
0.76
Ener
Pro 5.1 by EnergySoft
User Number: 6712 RunCode: 2012-06-08711:52:24 ID:
Page 8 of 14
•
•
•
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
OPAQUE SURFACE DETAILS
Surface U
Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC4
Azm Status
Glazing Type
Location/Comments
49
Window 48.0
0.790 Default
0.59 Default 180 Existing
Double Metal Tinted
Existing Residence
50
Window 40.0
0.790 Default
6.59 Default 276 Existing
Double Metal Tinted
Existing Residence
51
Window 11.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
52
Window 11.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
53
Window 11.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
54
Window 180.0
0.790 Default
0.59 Default 270 Existing .
Double Metal Tinted
Existing Residence
55
Window 15.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
56
Window 15.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
57
Window 15.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
58
Window 5.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
59
Window 5.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
60
Window 5.0
0.790 Default
0.59 Default 270 Existing
Double Metal Tinted
Existing Residence
61
window 8.0
0.790 Default
6.59 Default 270 Existing
Double Metal Tinted
Existing Residence
62
Window 8.0
0.790 Default
6.59 Default 270 Existing
Double Metal Tinted
Existing Residence
63
Skylight 36.0
0.800 NFRC
0.39 NFRC 0 New
Double Metal Tinted Skylight
Addition
64
Window 4.0
0.550 Default
0.55 Default 0 New
Double non-metal tinted
Addition
(1) LI -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hanq
Len H t LExt
Left Fin Ri ht Fin
RExt Dist Len H t Dist Len H t
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
56
Bug Screen
0.76
57
Bug Screen
0.76
58
Bug Screen
0.76
59
Buc Screen
0.76
60
Bug Screen
0.76
61
Bug Screen
0.76
.62
Bug Screen
0.76
63
INone
1 1.00
64
IBug Screen
1 0.76
Ener
Pro 5.1 by EnerqySoft
User Number: 6712
RunCode: 2012-06-08711:52:24 ID:
Page 9 of 14
•
•
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Traditions Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/8/2012
OPAQUE SURFACE DETAILS
Surface U- Insulation ,Joint Appendix
Type Area Factor Cavity Exterior I Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments
65 Window 20.0 0.550 Default 0.55 Default 0 New Double non-metal tinted Addition
66 Window 4.0 0.550 Default 0.55 Default 0 New Double non-metal tinted Addition
67 Window 20.0 0.550 Default 0.55 Default 0 New Double non-metal tinted Addition
(1) U -Factor Type; 116-A = Default Table from Standards; NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t
65 Bug Screen 0.76
66 Bug Screen 0.76
67 Bug Screen 0.76
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-08T11:52:24 ID: Pae 10 of 14
C
•
L
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Traditions Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
6/8/2012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New ' Existin Altered Removed • Volume Year Built
HVAC Existing Existing Residence
3,970
47,640 1990
Addition
345
4,140
Totals 3451, 3,970 0 0
HVAC SYSTEMS
System Name Oty. Heatin Type
Min. Eff. Cooling IXpe Min. Eff. Thermostat Type Status
HVAC Existing 5 Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Coolinq Duct Location R -Value
Ducts
Tested? Status
HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard 50gal. or less
2
Small Gas
All Pipes Ins
40,000
50
0.61
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
_ o
v
a —
S stem Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty. HP
.
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number: 6712
RunCode: 2012-06-08711:52:24 ID:
Pae 11 of 14
0
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Traditions Residence
Date
6/8/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area a and is
equipped with a with a readily accessible, operable, and tight-fittinq damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§1500): Heating systems are equipped with thermostats that meet the setback re uirements'of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1.500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R=12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
re irculatinq sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-08711:52:24 /D: Page 12 of 14
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Traditions Residence
6/8/2012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal Openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by 4150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySo/f User Number: 6712 RunCode: 2012-06-08711:52:24 ID: Page 13 of 14
•
•
.0
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Traditions Residence
6/8/2012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulatedceilings shall be listed for zero clearance Insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain 'a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles, shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoR User Number: 6712' RunCode: 2012-06-08711:52:24 /D: Page 14 of 14