Loading...
06-3891 (AR).�1 s P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 06-00003891. 53090 DEL GATO DR 770-330-027- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 44635 c&ht 4.4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: Lic. No.: --------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business nd Profess' nals Code, and my License is in full force and effect. License Class: B Lice, a No.: 677600 'Date: 7— — G Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penaltyofperjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the .structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason 'tv Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the 4 work for which this permit is issued (Sec. 3097, Civ. C.)., Lender's Name: _ Lender's Address: LQPERA11T Owner: MARTIN CRAIG LEE 53-090 DEL GATO LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/05/07 Contractor: GUSTAFSON CONSTRU P O BOX 10427 D W PALM DESERT, CA (760)340-3462 Lic. No.: 677600 V L C1TY�Qe� A WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1795609-2007 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become s bject to the workers' compensation laws of California, and agree that, if I shout become subj t to the workers' compensation provisions of Section 3700 of the Labor Cod , I shall fort th comply ith those provisions. Date: 3'-? -0-? Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the, conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws'relating to buildin constructi n, and hereby authorize representatives of this county to enter upon the above-mentioned prop ty r inspect' purposes. Date:3— 7 �f!%� Signature (Applicant or Agentl: Application Number . . . . . 06-00003891 Permit . . . . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 382.00 Plan Check Fee 248.30 Issue Date . . . . Valuation 44635 Expiration Date 9/01/07 Qty Unit Charge Per Extension BASE FEE 252.00 20.00 ---------------------------------------------------------------------------- 6.5000 THOU BLDG 25,001-50,000 130.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 31.88 Plan Check Fee 7..97 Issue Date Valuation . . . . 0 Expiration Date . 9/01/07 Qty Unit Charge Per Extension BASE FEE 15.00 468.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 16.38 25.00 --------------- ----- .0200 ------ ELEC ----------- GARAGE OR NON-RESIDENTIAL --------------------------- .50 ------------ Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00. Issue Date Valuation 0. Expiration Date 9/01/07 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 42.00 Plan Check Fee 10.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/01/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 9.0000 EA* MECH B/C <=3HP/100K BTU ----------------------- 9.00 ----------------------------------------------------- rA Permit . . . . . . PLUMBING N LQPER\IIT Application Number . . . . . 06-00003891 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 58.50 Plan Check Fee 14.63 Issue Date . . . . •Valuation . . . . 0 Expiration Date 9/01/07 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP .3.00 3.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 9.00 ---------------------------------------------------------------------------- Special Notes and Comments PATIO 476 SQ. FT. / ROOM ADDITION 468 SQ. FT. ---------------------------------------------------------------------------- Other Fees . . . . . . . . ENERGY REVIEW FEE 24.83 STRONG MOTION (SMI) - RES 4.46 Fee summary Charged --------------------------- Paid Credited -------------------- -------- Due Permit Fee Total 529.38 .00- .00 529.38 Plan Check Total 281.40 .00 .00 281.40 Other Fee Total 29.29 .00 .00 29.29 Grand Total 840.07 .00 .00 840.07 1! LQPERDIIT vca H11i1t76 9FX/{PP City of La Quinta Building & Safety Division P.O: Box 1504, 78-495 Calle Tampico La Quinta, CA 92253- (760) 777-7012 Building Permit Application and Tracking Sheet , ermit # QQ �. Project Address:' S3 --Q O' �z d 197-o Owner's Name: 3) "119161% A. P. Number: �� 3 Address: Legal Description: City, ST, Zip: Contractor: Telephone: % : ;,'IZ Zia Address: Project Description: City, ST, Zip: A7 D rc) Telephone; p �� �3 2 4 ,: �_ I State Lie. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: /'�� �5��� � � N Telephone: 17� -� �j 1 3 _ -.�� - `� , .� _. - Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo State Lie. #: - -2 rye©- Name of Contact Person: A/11 /Q 067 �S �'Q fj� Sq. Ft.: ores: # Units: Telephone # of Contact Person: % % Estimated Value of oject• ' APPLICANT: DO NOT WRITE BELOW THIS LINE 11 Submittal Req'd Rec'd TRACKING , PERMIT FEES Plan Setstl Plan Check submitted 3 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Cheek Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted G Mechanical Grading. plan 2°d Review, rea for correctio `' a j4, jp Electrical Subcontactor.List Called Contact Person Plumbing Grant Deed Plans picked up z14S.M.I. H.O.A. Approval Plans resubmitted0 7 Grading IN HOUSE:- ''" Review, ready for correctio issue �JH6, Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue Q School Fees Total Permit Fees vca H11i1t76 9FX/{PP v CERTIFICATE OF COMPLIANCE ALL, sc�o Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DU�O 10 RANCHO MIRAGE Date 2/23/07 La Quinta, CA 92253 N INDIAN WELLS ti No. 29255 (760) 771-8515 fir`, PALM DESERT V LANQUTA DINO y 40- 0 yr3 O Owner Craig Martin APN # 770-330-027 Address 53090 Del Gato Dr Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53090 Del Gato Dr Unit 2 Unit 3 Unit 4 Unit 5 Comments 468 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 468 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Sandra Hand Check No. Name on the check Telephone Funding Exempt By Ar. Doris Wilson Superintendent .� . Fee collected /exem d by a o ilvrey Payment Recd : * $0.00 O J ..Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1��ti a to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the de building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting Tradition November 9, 2006 — Revised November 15, 2006 Mr: and Mrs. Martin c/o Juan Carlos Ochoa 73626 Highway 111 Palm Desert, CA 92260 Re: Lot 63, Tract 28867, 53090 Del Gato Architectural Modification Dear Mr. & Mrs. Martin: The Tradition Architectural Design Review Committee reviewed and approved the modification request for Lot 63 on Del Gato with the following conditions. 1. All new work shall match the existing building. . 2. The left side yard property line wall should be extended the entire extent of the new addition to comply with the ADRC Guidelines. 3. Revised planting was submitted for committee review. Please contact Brook Marshall at (760) 219-8057 or by email at BrookOdc.rr.com with any questions or to schedule your Pre -Construction Meeting at the lot prior to beginning the remodel. Sincerely, Tradition Architectural Design Review Committee a: ARRC Rle DESERT RESORT MANAGEMENT • POST OFFICE BOX 4772 • PALM DESERT, CALIFORNIA 92261-4772 73-550 ALESSANDRO, SUITE 5 • PALM DESERT, CALIFORNIA 92260 PHONE (760) 346-1161 • FAx (760) 346-9918 � a V CITY OF LA QUINTA . PLAN CHECK CORRECTION LIST Ochoa Design Associates 73-626 Highway 111 Palm Desert, CA 92260 PLAN CHECK NO. 06-3891 ADDRESS 53-090 Del Gato SCOPE OF WORK Addition February 5, 2007 SECOND/FINAL CHECK(Structural Review only) . OCCUPANCY R -3/U-1 TYPE -OF -CONST. V -N The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE -CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: VCA�CODE GROUP 2200 W Orangewood -Ave, Ste 155 Orange, CA 92868 (714) 363-4700 ext. 1 VCA File No. LQ -19147 . r - TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 7 9 11 EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R _Martl.q Resirienne Project Title )� Dan nol riato Drive I 2/21/2007 Date Project Address a Quinta Building Permit # Ins_�_form Inc (760) 779-0657 Documentation Author Telephone Plan Check/Date FnergyPrn Compli ce Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.11 2.46 -0.35 Space Cooling 141.31 130.47 10.84 Fans 18.99 17.60 1.40 Domestic Hot Water 7.13 4.47 2.66 Pumps 0.00 0.00 0.00 Totals 169.54 155.00 14.54 Building Type: rd: Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition Q Existing + Add/Alt (W) 270 deg Natural Gas Area: 804 ft 2 Avg. U: 0.87 Ratio: 16.1% Avg. SHGC: 0.70 8.6% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 14.5 nn 074 R-1 9R-0 d?�n _gIl Wall Wood 198 0074 R-19 R_Q_]Z _Q A Wall Wood 96 0 074 R_19 R-pn 180 A nnnr Anne 4n 0 500 None R_n n is() A Roof Wood 468 n02c R_38 R 0 0 270 Wall Wood 262 0 102 RR -13 R -n 027n _SQ nnnr Nnne 48 1 450 Nnne R -n 0 970 _gj] Wall Wnnd— 34-5 n 109 R_13 R_n n —IL-9Il Wall Wood 280 0102 R-13 R-0.0 An An Wall Wood791 0 102 R-13 R_0 0 18n 90 Roof Wood 4 S08 0 049 R_19 R -n n 97n p Zone Type Conditioned Cnnditioned Thermostat Type Setback Setback 4,976 ft2 4,508 ft2 0 ft2 4,976 ft2 10.0 ft 1.00 1 Vent Hgt. Area ala �2 _Ola Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑ New n9 -A5 Addition ® ❑ New 09 -AS Addition ® ❑ New 0IAS Addition ® ❑ New 5PR-A4 Additinn ® El New-- 01-A18 Addition ® Existing 09-A3 Fxisting Living ® ❑Fxisting_ 98-A1 Fxisting Il iving ® ❑Fxisting_ n9 -A3 Fxisting I iving ® ❑Fxisting 09-A3 Fxisti iving ® ❑Fxisti g 09-A3 Existing Living ® ❑Fxisti g 01-A4 Fxisting I iving ❑ ❑ ❑ ❑ ❑❑ F-1 F-1 ❑❑ F-1 F-1 ❑❑ ❑❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:3 of 12 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Martin Residence 2/21/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments J- 2 3 4 5 6 Window Window Window Window Window Window Front Front Left Right Right Front ON) (W) (N) (S) (S) (W) 48-4 n 870 NFRC_-OLZO NFRC 97n _90_ New Double Mtl Uncoated Default 6.3 0.870 NFRC 0_70 NFRC 270 90 New Double Mtl Uncoated Default 2.0 0.870 NFRC 0.70 NFRC 0 90 New Double Mtl Uncoated Default 40.0 0.870 NFRC 0_70 NFRC 180 90 New Double Mtl Uncoated Default 24.0 0.870 NFRC 0`70 NFRC 180 90 New Double Mtl Uncoated Default 48.3 0.870 NFRC 0.70 NFRC 270 90 Removed Double Mtl Uncoated Default Addition Addition Addition Addition Addition Existing Living L 8 Window Window Front Left (W) (N) 40.0 0.870 NFRCQZ4 NFRQ 270 90 Existing Double Mtl Uncoated Default 10.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Existing Living Existing Living 6 Window Left (N) 3.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default Existing Living 1Q I Window Window Left Left (N) (Nj 12.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default 16.0 0_870 NFRC 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default Existing I Nino' Existing Living 12 Window Left (N) 10.0 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Existing Living Ja Window Left (N) 24.0 0.870 NFRC 0 70 NFRC 0 __qQ Existing Double Mtl Uncoated Default Fxisting Living 14 Window Rear (E) 192.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Existing Living 15 Window Rear (E) 64.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Existing Living 16 Window Rear (E) 40.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Existing Living 17 Window Rear (E) 40.0 0.870 NFRC 0_70 NFRC: 90 90 Existing Double Mtl Uncoated Default Existing Living 18 Window Rear _(E) 40.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Existing Living JQ Window Rear (E) 64.0 0.870 NF$C0.70 NFRC 90 90 Existing Double Mtl Uncoated Default Existing Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 Window Addition Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 7.2 6.9 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.0 2.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.8 3.0 2.0 0"1 2.0 2.0 5 Bug Screen 0.76 8.0 1.6 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.0 6.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 2.5 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 10.0 24.0 6.0 0.1 6.0 6.0 15 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 New Addition Slab Perimeter 180 None No Insulation 26-A1 Existing Existing Living Run Initiation Time: 02/21/07 16:10:01 Run Code: 1172103001 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:4 of 12 .Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Martin Residence 2/21/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 20. Window Right S) 4on 0 870 NFgc 1370 NFBC 180 --qd xictino Double Mtl Ulneoated nefault Fxicti i_ving 21 Window Right (S) 56.0 0.870 NFRC 0_70 NFRC 180 90 Existing Double Mtl Uncoated Default Existing Living 22 Window Right (S) 20.0 0.870 NFRC 0_70 NFRC 180 90 Existing Double Mtl Uncoated Default Existing Living 23 Window Right (S) 12.0 0.870 NFRC 0_70 NFRC 180 .90 Existing Double Mtl Uncoated Default Existing Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 l 21 Bug Screen 0.76 7.0 6.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type L Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 02/21/07 16:10:01 Run Code: 1172103001 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:5 of 12 Certificate Of Compliance: Residential (Part 3 of 3) CF -1R Martin Residence Duct Condition Ducts Location Heating Cooling Location R -Value Status 2/21/2007 Project Title 4.2 New No Living Zone Ducted Ducted Attic Date No HVAC SYSTEMS Status or RE Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas No Pipe Insulation _1 _ 43,000 50 New 0.60 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Addition Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Living Zone Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Addition Ducted Ducted Attic 4.2 New No Living Zone Ducted Ducted Attic 2.1 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas No Pipe Insulation _1 _ 43,000 50 New 0.60 n/a i n/a Standard Gas 50 gal or Less Small Gas No Pipe Insulation _2_ 40000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) M. - Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Joan D. Hacker Title/Firm: I nsu-form. Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephne: 760 779-0657 LU 0 r (sign tur) (date) STAMP Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ElF ❑ El § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ e§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ r. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. b. outside air intake with damper and control, Flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ ❑ CF -6R Form: EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 12 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Coefficient (SHGC), and infiltration certification. Q ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ r ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 12 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ O ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 1 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ I ! Elt sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. i 11 El El 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGHOUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, E ❑ n ❑ luminaire has factory install HID § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility, rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 11 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ FAI ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:8 of 12 IHVAd SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Martin Residence 2/21/2007 SYSTEM NAME FLOOR AREA Addition 468 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sqft) 170.9 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 121.8 Total Output (sgft/Ton) 98.5 Air System CFM per System 1,905 Airflow (cfm) 1,905 Airflow (cfm/sgft) 4.07 Airflow (cfm/Ton) 401.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Vote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 69.4 OF 69.4 OF Outside Air 0 cfm 69.4 of 11.0 / 77.4 of Outside Air 0 cfm 79.5/65.3 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 941 17,106 1,242 242 9,831 0 3,043 1,261 0 0 0 0 0 0 0 0 0 3,043 1,261 23,191 1,242 12 353 Bryant Air Conditioning 539GN060-A 40,712 10,374 80,000 Total Adjusted System Output 40 712 10,374 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 108.6 of Supply Fan Heating Coil 1905 cfm �% Return Air Ducts 4 79.5/65.3OF 79.5/65.20F a 59.6/58.30F Supply Fan Cooling Coil 1905 cfm �% Return Air Ducts `i Supply Air Ducts 107.9 of ROOMS 70.0 of Supply Air Ducts 61.0 / 58.8 of 49.5% R.H. ROOMS 78.0/64.8OF EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:9 of 12 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Martin Residence 2/21/2007 SYSTEM NAME FLOOR AREA Living Zone 4,508 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11 COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 3,367 77,167 5,056 1,409 67,441 0 18,203 11,632 0 0 0 0 0 0 0 0 0 18,203 11,632 113,5741 5 056 90 704 HVAC EQUIPMENT SELECTION Existing HVAC 125,780 0 210,000 Total Adjusted System Output 125,780 0 210,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 67.2°F 67.2°F 117.40F Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 114.7 °F 3900 cfm ROOMS 70.0 OF 67.2 °F r y% Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Coolina Peak) I 11.0/77.4°F 82.4/62.5°F 82.4/62.3°F® 52.3/50.6°F 1 - � Outside Air 0 cfm 82.4/62.5 °F Supply Fan Cooling Coil 3900 cfm h Return Air Ducts y Supply Air Ducts 56.6 / 52.4 of 37.2% R.H. ROOMS 78.0 / 61.0 OF I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Paae:10 of 12 1 ROOM LOAD SUMMARY ::1 PROJECT NAME Martin Residence DATE 2/21/2007 SYSTEM NAME Addition FLOOR AREA 468 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 941 17,106 1,242 941 17,106 1,242 242 9,831 PAGE TOTAL 1 941 17,106 1,242 242 9,831 TOTAL 1 941 17,106 1,242 242 9,831 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 12 ROOM LOAD SUMMARY ::1 PROJECT NAME Martin Residence DATE 2/21/2007 SYSTEM NAME Living Zone FLOOR AREA 4,508 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ExistingLiving1 Existing Living 3,367 77,167 5,056 3,367 77,167 5,056 1,409 67,441 PAGE TOTAL 1 3,367 77,167 5,056 1,409 67,441 TOTAL 1 3,367 77,167 6,066 1,409 67,441 EnergyPro By EnergySoft User Number: User Job Number: Page:12 of 12