Loading...
14-0593 (BLCK)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 14-00000593 Property Address: 53150 DEL GATO DR APN: 770-350-001- - Application description: WALL/FENCE Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 8000 T4ht 4Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: JOHN ABEL Contractor: Applicant: Architect or Engineer: RAS MASONRY INC 16780 CRESCENT GLEN COURT RIVERSIDE, 92503 (760)774-0090 Lic. No.: 678140 1 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licensess: C29 License No.: 678140 Date: Contractor: _ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to .construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/07/14 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier INS CO OF WEST Policy Number WSD502042502 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section �� 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Appli ant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND'SHALL - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION -TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this my to enter upon th bove-mentioned property for inspection purposes. atD e: Signature ((Applicant or Agent): Application.Number . . . . . 14-00000593 Permit . . . WALL/FENCE PERMIT 2013 Additional desc . Permit Fee 108.68 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 8000 Expiration Date . . 11/03/14 Qty Unit Charge Per Extension 1.00 47.1900.LS MISC WALL, FIRST 100 LF 47.19 1.00 47.1900 LS MI RET WALL <=121, 1ST 100' 47.19 1.00 14.3000 EA MI RET WALL <=121, ADDL 50' 14.30 - --------------------------------------------------------------------------- Special Notes and Comments 130LF OF 5FT HIGHT RETAINING AND 70LF OF 6FT HIGH GARDEN WALL, PER ATTACHED APPROVED PLANS AND ANGELUS/ORCO SPECIFICATIONS, PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 1..00 PLAN CHECK, WALLS 120.12 Fee summary Charged Permit Fee Total 108.68 Plan Check Total .00 Other Fee Total 121.12 Grand Total 229.80 LQPERMIT Paid Credited Due .00 .00 108.68 .00 .00 .00 .00 .00 121.12 .00 .00 229.80 Bin# City of La Quinta Building 8i: Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # /,� Project Address: I Owner's Name: G A. P. Number: 0,, Address: Legal Description: City, ST, Zip: Contractor: S Telephone: Address: Project Description: City, ST, Zip:),70 LC .910 A -A,11 V1 17 Telephone P r 0 o9a "•' f .Y � 1 State Lic. # : City Lie. #.. Arch., Engr., Designer: 1 1. Address: Als vvy City, ST, Zip: h Telephone: ..:......... ............................ Construction type: Occupancy: cY• State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stori s: # Units: Telephone # of Contact Person: Estimated Value of Project: KVO APPLICANT: DO NOT WRITE BELOW THIS LINE tl Submittal Req'd Rec'd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cala. Called Contact Person Plan Check Balance Title 24 Cala. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan god Review, ready for correctionstissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person. A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees d4yll ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2010 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25,' COHESION = Opsf 5. CANTILEVER ACTIVE = 45pcf NO SURCHARGE 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.1 EXCEPTION 3, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES:- 1. OTES:1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. NOT USED. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. NOT USED. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS SEE DETAIL SHEET S-5.1. H' I16' LONG CMU -- �Z'Y BARS I 'B' MIN. I 'C' MIN. I V I � ?'—n' I adAwti-_ r i u d I I.—tali-1. ,-1n 1 E'Q''��aG•7I�l�1C El ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badlllo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 eng/nee�ing exCe11en since 1957" 2' to 6' High Retaining Wall Sloped Backfill 8w Wide CMU #4 HORIZ. ®24"o.c. 8' WIDE (NOM.) FULLY GROUTED 'X' BARS PER SCHEDULE - 4'0 SDR 35 PERF. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 140N FILTER FABRIC- - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL F.G. WET-SETFIRST ?til COURSE #4 CONT. #4 CONT. 012'o.c. CONT. CONC. FT .�- 'Y BARS PER 3' CU SCHEDULE TYP• CONC. KEY D' 'B' MIN. PER SCHEDULE SM1W 15W dAMPUDf(1 ® O�B cZq.'S1XtAFETY APPROVEI FOR CON TRUCTI N/ DATE _ 12" 1 'H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION BACKFILL - WELL GRADED, CLEAN SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 2 2j -OUTSIDE FACE OF BLOCK TO ti OF VERT 'a N rr C3 w w i = N Of CL N b NED 5-20-13 S-1.8 #6255 `v ORCO STANDARD 6' TO 8' CMU SITE WALLS 'W CONT. FOOTING 5, CONCRETE BLOCK SHALL BE LAYED INA -RUNNING BOND PATTERN WITH VERTICAL CON77NLUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPES MORTAR PROPORTIONED USINGAS774 C270 PART CEMENT TO 1/2 PART LIME TO 4-W PARTS DAMP, LOOSESAND. 8. GROUT FOR CONCRETE BLOCK PER A5TM C 476 TO BE 1 PART CEMENT TO 3 PAR 75 SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PFA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL. SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTTUENTS. 9. BLOCX STEM MAY BE WET -SET 1-1/2' INTO THE FOOTING WHILE THE CONCRETE IS PLAS77C BLOCK STEN MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING,. 10. F0077NG MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. #4 HORZ CONT. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE SECOND 96PEMON TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING 40'O/C 20' O/C FOR WALLS TO BE MORTAR WASHED OR STUCCO COATED. SEE CHART FOR REQUIRED REBAR AND FOOTING DIMENSIONS. 25/8'MIN. CLEAR CELL OPEN REQUIRED TO USE 6616 SLUMPED CMU. [C::D 0 ORCO WIDE CELL SLUMP VSOFESSIO 61 y � r m ~ C31925 N A * Exp. 12-31-2014 1p qT C I V FO OF CAl\F -1--- OPTIONAL FLAT CAP DESIGN CRITERIA: PER THE 2010 CBC 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF 2. ALLOWABLE LATERAL P455IVE PRESSURE = 150 PCF 3. GROUT STRENGTH =1000 PSI @ 28 DAYS 4. REINFORCING STEEL : GRADE 60. 5.1500 PSI MASONR Y COMPRESSION STRENGTH - NO SPCL. INSPECTION 6816, 6616, OR 6618 CMU GROUTED ONLY @ VERT NOTES: STEEL 1. CONCRETE BLOCK SHALL CONFORM TO ASTM C 90. WFDG EOCX BLOCK, SLUMP BLOCKANDSPLITFACEBLOCKAREACCEPTABLE Y' DROP-IN BAR L CONCRETE FOR F0077NGSHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL W17HA MAXIMUM OF 1-1/1 GALLONS OF WATER PER S4CC PORTLAND CEMBVT SHALL CONFORM TO ASTM C 150 TYPE HIV Fc = 2500 PSI 06 STD JOINT REINFORCEMENT @ 24"01C 3. REINFORCING STEEL STALL BE DarRMED AND CONFORM TO (3 PLACES - 4 PLACES FOR 7 A5774A 615 GRADE 60, PROVIDE 411 114R DIAMETER LAP. & B' WALLS). USE #5 STD. FOR SLUMP BLOCK 4, RES4R SHALL BE CFN7SZED IN THE CONCRETE BLOCK CELL IN WHICH 1T LS LOC47ED. 'W CONT. FOOTING 5, CONCRETE BLOCK SHALL BE LAYED INA -RUNNING BOND PATTERN WITH VERTICAL CON77NLUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPES MORTAR PROPORTIONED USINGAS774 C270 PART CEMENT TO 1/2 PART LIME TO 4-W PARTS DAMP, LOOSESAND. 8. GROUT FOR CONCRETE BLOCK PER A5TM C 476 TO BE 1 PART CEMENT TO 3 PAR 75 SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PFA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL. SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTTUENTS. 9. BLOCX STEM MAY BE WET -SET 1-1/2' INTO THE FOOTING WHILE THE CONCRETE IS PLAS77C BLOCK STEN MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING,. 10. F0077NG MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. #4 HORZ CONT. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE SECOND 96PEMON TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING 40'O/C 20' O/C FOR WALLS TO BE MORTAR WASHED OR STUCCO COATED. SEE CHART FOR REQUIRED REBAR AND FOOTING DIMENSIONS. 25/8'MIN. CLEAR CELL OPEN REQUIRED TO USE 6616 SLUMPED CMU. [C::D 0 ORCO WIDE CELL SLUMP VSOFESSIO 61 y � r m ~ C31925 N A * Exp. 12-31-2014 1p qT C I V FO OF CAl\F CHART FOR 6' TO 8' SITE WALL W/ SPREAD FOOTING WIND MAX. 'Wl DESIGN WALL SPREAD 'X' DOWEL 'Y' BAR SPEED HEIGHT T/NG WIDTH /DTH #4 @ 48" 0/C 33" #4 @ 48" O/C U U 6'-0" 11-91, 48. 0/C FOR 6' 48' O/C FOR 6- w SLUMP BLOCK. 8„ _ $„ — SLUMP BLOCK. ►� Lu #4 @ 48" 0/C 33" #4 @ 48" 0/C Q Q 6'-8" 1'-I I" 40' 0/C FOR 6' 40' O/C FOR 6• Z w SLUMP BLOCK. I O" — IO" —L SLUMP BLOCK. w IL _ #4 @ 40" 0/C 33" #4 @ " 0/C %'-4" — 32' 0/C FOR 6' 32' 0/C FOR 6' N SLUMP BLOCK. I O" -- lo.. BLOCK. :3 U-) °o #4 @ 32" 0/C — 33" #4 @ 32" 0/C 8'-0" 2'-4" 24' 0/C FOR 6' ' L 24' O/C FOR 6' SLUMP BLOCK. 12" -- 12" SLUMP BLOCK. NOTE: FOR 18" LONG BLOCK USE 9"INCREMENT REBAR SPAQNG THAT IS CLOSER TOGETHER THAN THE 16" LONG BLOrX SPAQNG. FOR EXAMPLE- 46- O/C SPAQNG FOR 16" LONG BLOCKREVERTS TO 45" O/C FOR 18" LONG BLOCK, 40" FOR 16" BLOCK GOES TO 36" O/C FOR 18" BLOCK - ET 84 DOWEL LID E40f SIDE OF BLOCK-OUT W/ X4 DROP RV W 8718BL0C*OUT r CUNT. FOMNG IDR SJDtYARD RFTL/RIY WALLA S WHERE lMAILIIA[al° A==LA 1/2 BLOCK MAYLEFT OUT @ SWALEG7?ADE PROVIDE 04 DOWEL AND 04 DROP-IN W ON FACH SIDE OF THE 112 BLOCK OWN - AS SHOWN. CITY OF L4 QUINTA ft=. t *744 aam c /6t A" N/RgZ awr.O R°ASM=)tm- "iW'G wmX wMD111pY7ApVT aGIR"E!Mffi 0 D D O p 0 2 v v D.• •D o'O .D e 1 '1 � NIr1.aKs OR aW%CMFt s L mmm—wom-m-mv— mxur�wff"rmmmm sm QROFE ON y �I _ � m ~ C31925 (n * Exp. 12-31-2014 s9 C,V1 �v TF 0F CAl\F09-