Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-0698 (AR)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTAj CALIFORNIA 92253 Application Number: ' i-11-00000698 Property Address: 53960 DEL GATO .DR APN: 770-380-001— — Application description: ADDITION — RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 85000 Applicant: Tit!t aF 4 Q" Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: WILSON STEVEN K & BARBARA L 53960 DEL GATO DR LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/14/11 a � a Contractor: SUN VISTA DEVELOPMENT CO �,`© P.O. BOX 1144 `-'I 1 -4201i qqyy LA QUINTA, CA 92247 (760) 771-4722 CITY OF LAQIANiA Lic. No.: 744091 FI`VANCiEDEPT ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that Iam . sed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business Pro ssionals Code, and my License is in full force and effect. Licen Class: B License No.: 74 091 Dat(��i�r�� tractor: (('' O NER- UILVRDECLARRATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the . improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 1 am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY _ I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:`` �( Lender's Address: Tom' LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000179-2009 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to beco u the ject to the workers' compensation laws of California, and agree that, if I should beco subje to workers' compensation provisions of Section !317090 of the Labor Code, I s forth th comply with those provisions. L aD teV•r� pplicam: WARNING: FAILURE TO IO SECUR W KER COMP S N COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CR AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 15100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or'following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days willsubject permit to cancellation. I certify that I have read this application and state that the above i rmati n is correct. I agree to com ith all city and county ordinances and state laws relating to building c structio , an ereby uthorize re sentatives ofim ft�ths county to enter upon the above-mentioned property to specti purpr es. Oat�J/Sig re (Applicant or Agent): Application Number . . . . . 11-00000698 ------ Structure Information 236SF BAR ADDITION/VB/RES-3/CL A [ENG] ----- Other struct info . . . . . CODE EDITION 2010 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE ---------------------------------------------------------------------------- 236.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 572.00 Plan Check Fee 371.80 Issue Date . . . . Valuation . . . . 85000 Expiration Date 3/10/12 Qty Unit Charge Per Extension BASE FEE 414.50 35.00 4.5000 THOU BLDG 50,001-100,000 ---------------------------------------------------------------------------- 157.50 Permit. . . ELECT`- ADD/ALT/REM Additional-desc . . Permit Fee . . . . 19.72 Plan Check Fee 4.93 Issue Date . . . . Valuation . . 0 Expiration Date 3/10/12 Qty Unit Charge Per Extension BASE FEE 15.00 236.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL -------------------=-------------------------------------------------------- 4.72 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 36.00 Plan Check Fee 9.00 Issue Date . . . . Valuation 0 Expiration Date 3/10/12 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 236SF BAR ADDITION/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, PATIO COVERS OR THE INSTALLATION, OR ALTERATION TO THE EXISTING, MECHANICAL SYSTEMS. 2010 CALIFORNIA BUILDING CODES. September 12, 2011 1:46:16 PM AORTEGA LQPEENLT Application Number . . . . . 11-00000698 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 4.00 ENERGY REVIEW FEE 37.18 STRONG MOTION (SMI) - RES 8.50 Fee summary ----------------- Charged Paid ---------- Credited ---------- Due Permit Fee Total ---------- 627.72 ---------- .00 .00 627.72 Plan Check Total 385.73 .00 ® .00 385.73 Other Fee Total 49.68 .00 .00 49.68 Grand Total 1063.13 .00 .00 1063.13 LQPERAIIT 11/17/2003 14:28 7603469918 DESERT RESORT MGMT PAGE 02/02 (rra d itio n N-1 November 10, 2003 Sir Richard and Lady Jane George Re: 53960 Del Gato Drive Dear Sir and Lady George, The Tradition Architectural Committee has reviewed your second submittal of construction documents for your Tradition home. The plans were approved subject to the following comments: 1. The licensed architect or approved designer on the project needs to be listed on the title sheet. 2. The pad height will need to be verified for lot 92 for wall height verification. 3. The landscape plans are approved as resubmitted with the understanding that the committee will approve the shrub and tree locations on the slope in the field prior to planting. 4. Please re -review the drywell and retention area. If the drywell is sized appropriately, why is the retention needed? 5. The drywell grate cannot be visible, a 6" cleanout is required. 6. A $5,000.00 construction performance deposit will be required prior to the onset of construction. Please make this check payable to: Tradition Community Association. We thank you for your submittal and look forward to working with you further on the construction•of your home. Sincerely, The Tradition Architectural Committee Tradition Community Association cc: Gordon Stein PCM/DESERT RESORT PROPERTY MANAGEMENT COMPANY POST OFFICE BOX 4772, PAL \1 DESERT, CALIFORNIA 92261.4772. 73 -SW ALESSAAIDRO, SUITE o, PALM DESERT, CALIFORNIA 92260 PFloNE: (760) 346-1161 - FAx: (760) 346.9918 JCM Inspections 39725. Garand Lane Suite F I Palm Desert, CA 92211 I ItiSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS EPDXY INSPECTION REPORT Date: -a3—o Project Name: Project No: a c1�1 LG Z% 03L in ('_-,A-- - 1, (� AS 1 i C� e �-o Z* .. Project Address: ,CCitly: J 3 �a0 Qoh\ t�,n LlXv�„� ct �b� Title 24 AWS � C� Other: File# ❑D1.1 App# ❑ D 1.4 ❑ Other Client: Sub -Contractor: (�C J \� v O oc_ICA.— General Contractor: Architect: Architect: Structural Engineer: \Ira 9 -Anchor Bolts ❑ Rebar Epoxy Type: �1 pS� �. n .n t. \ \ 2� , • -7� Epoxy Shelf Lifer �A - pp r Hole Cleaning Method(s):V9\^, 1kr, C�„� j �6e rQw, VAe C,0 3,1 Cl s� Weather: t1t1 tA Unresolved=I ems: ®None ,❑ See Below Description of Work Inspected: ��TvX e(lc�A^ C- Q` up t �. l- X13 a - Afit a o fl - �1Q CSL O oo KiQ-�aL i e��[a Q X'1,r, .n Gt"a ✓1� �'�.:�n t` C- to t• Q Q�Lt \ ,. n I 11 c ,rat \ii n o 1,__Q i �J`� � � �� P no lL, C. fcl.t 11 Y1 A 1 1 i . c- C7 P AV n 14 c• k t l t a s% ett r&IiNo Q r el n ZY►. ' C O.4.1 wn.o .. r , .. r1 A�. Work complies with written approval from Structural Engineer and ICBO Evaluation Report #4:::Z -CAV) I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. lt ck C. Millin I�qrliic4�ffj ioln No: 0842216-49 Inspector:xt�-A_� . �\�..1�...w.� Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of 09/_22/2004 09:52 7603605719 YOUNG ENGINEERING SE PAGE 02 YOUNG ENGINEERING SERVICES 77-804 Wildcat Dr., Stc. C. Palm Down, CA. 92211 (760) 3GO-577p fax (760) 360-5719 September 22, 2004 Tom Hartung Building Official City of La Quitntat Re: Sir Richard Georgie Residence. 53-960 Del Gato Drive, ,La Ouinta, Ca Dear Tom, We have performed Structural Observation per C.B.C. section 1702 for the above referenced project and find it to be in General Conformance with the approved City plans and calculations. Please note that this letter does not relieve the City or the Special Inspectors from determining compliance with the approved plans. I -f. you have any questions please call. Sincerely 2 - WEDDLE SURVEYING MAPPING, INC. Boundary • Construction • Topographic • Aerial Surveys • ALTA Surveys • GPS • Consulting March 25, 2004 Mr. Timothy R. Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253-1504 Re: Pad/Form Grade Verification City of La Quinta Lot 1 Tract No. 28470-3 53-960 Del Gato drive_ 3 _ TRADITIONS C.C. Dear Mr. Jonasson: We have performed a field survey to determine the vertical location of the building pad and form for the above referenced project. The elevation's observed are as follows: PAD (DESIGN) PAD (AS -BUILT) 145.50 145.5 FORM (DESIGN) FORM (AS -BUILT) 146.00 146.01 These field observations are in substantial conformance with the precise grading plans prepared by McGEE SURVEYING, INC. dated 10/09/03 and the building location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, WEDDLE SURVEYING MAPPING, INC. �OOND & o NO. 5570 M ;a * EXP. 09/30/05 David L. Weddle, President L.S. 5570, Exp 9/30/05 orCAUF���\� P.O. Box 10418 • Palm Desert, CA 92255-0418 73-960 Hwy. 111, Ste. 6 • Palm Desert, CA 92260 • 760.346.3748 E -Mail: WedSury@aol.com • Fax 760.346.3 749 0 s Bin # City Of LQ Quinta Building 8T Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: 1j tjRlY a Owner's Name: t G*0 A. P. Number: Address: 57-6—q(0t) DV V & Gft-t�� Legal Description: City, ST, Zip: ( A IOU III, C/N% ZZ$ 3 Contractor: Telephon . & • °?': Address: Project Description: x City, ST, Zip: Telephone:���•�� State Lie. # : City Lie. #- Arch., Engr., Designer. ©VI—ppH / 1 s --A ha.-, Address: City, ST, Zip: ?�a,LVA 7,) l I ('AgZZ I Telephone 7(,p) V9 State Lie. #: Name of Contact Person: (!0dYL-c-v-tA 47T!�--1 A Construction Type: Occupancy: Project type circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person -.(- Estimated Value of Project: J DOD r APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cslcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted ifizi Mechanical Grading plan 2'` Review, ready [ orrection slue It Electrical Subcoutector List Called Contact Person �� Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted t' Grading IN HOUSE:- ''+ Review, ready foF� $ Developer Impact Fee Planning Approval i Called Contact Person( A.I.P.P. A6 Pub. Wks. Appr Date of permit issueIL School Fees S Total Permit Ftes $O ll — is•�`E 'GO RS itrt� ?122 1 - 6�3'�i"3 pGct'c' 8-5 ✓� 16j;�!'�� �S T CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 9/14/11 La Quinta, CA 92253 No. 31101 (760) 771-8515 Owner Mr & Mrs. Wilson APN # Address 53960 Del Gato Drive Jurisdiction City La Quinta Zip Permit # Tract # No. of Units q� gIED&I zr-r7� o Q BERMUDA DUNES =� VJ RANCHO MIRAGE t f INDIAN WELLS PALM DESERT y LA QUINTA QINDIO y� 770-380-001 La Quinta Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53960 Del Gato Drive Unit 2 Unit 3 Unit 4 Unit 5 Comments Wet Bar Addition 236. Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 236 S.F. or $0.00 ' have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Rob Capetz Check No. Name on the check Telephone BY Dr. Sharon P. McGehee Superintendent Fee collected /exempt'd by Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will or other payment identified above will begin to run he date on wl which those amounts are paid to the District(s) or to another public en Funding Exempt Payment Recd 10.00 'OverlUtider you that the 90 -day approval period in which you may protest the fees g or installation permit for this project is issued, or from the date on to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting FW: From: Brook Marshall < To: rjccorp < Subject: FW: Date: Wed, Sep 7, 20112:54 pm From: Brook Marshall[mailto: Sent: Wednesday, September 07, 20112:52 PM To: Subject: September 6, 2011 Dr. and Mrs. Wilson 53960 Del Gato Drive La Quinta, CA 92253 Re: Lot 1, 53960 Del Gato Drive Remodel — Construction Documents #2 Dear Dr. and Mrs., Wilson: Page 1 of 1 The Tradition Architectural Design Review Committee reviewed and approved the revised plans for the remodel/addition at your home. As a note, the exterior light fixtures must be submitted for review and approval unless they will match the existing fixtures and any disturbed slope areas must be restored to pre -construction condition once the remodel is completed. Please contact Brook Marshall at (760) 219-8057 or by email at Brook@dc.rr.com with any questions or to schedule your Pre -Construction Meeting at the lot prior to starting the addition. Sincerely, Tradition Architectural Design Review Committee cc: Gordon Stein ADRC File http://mail.aol.com/34078-111/aol-6/en-us/mail/PrintMessage.aspx 9/14/2011 BUILDING ENERGY ANALYSIS REPORT ,PROJECT: Mr. Steve Wilson & Mrs. Barbara Wilson 53960 Del Gato Drive La Quinta, Ca 92253 Project Designer: "Design Mind Studio" Unique Residential Design 75-175 Merle Drive, Suite 200 Palm Desert, Ca 92211 1-(760) 773-4488 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 It -bin CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED JDATE A BY v Job Number: lg062511 Date: 7/20/2011 02TOTT JUL LL 2011 IU The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20711:15:00 ID: Ig062511 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 5.1 by EnergySoft Job Number: ID: Ig062511 User Number: 5732 1 2 3 13 16 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2011 Project Address 53960 Del Gato Drive La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,137 Addition 236 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 4,901 Perim = 0' Existing Wall Wood Framed R-21 4,700 Existing Roof Wood Framed Attic R-38 4,897 Existing Door Opaque Door None 56 Existing Slab Unheated Slab -on -Grade None 236 Perim = 0' New Wall Wood Framed R-21 375 New Roof Wood Framed Attic R-38 232 Radiant Barrier New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (NE) 114.0 0.500 0.38 none none Bug Screen Existing Rear (N) 276.0 0.500 0.38 none none Bug Screen Existing Rear (NlAq 141.0 0.500 0.38 none none Bug Screen Existing Rear(NVlq 140.0 0.500 0.38 none none Bug Screen Removed Front (SE) 248.0 0.500 0.38 none none Bug Screen Existing Front (S) 140.0 0.500 0.38 none none Bug Screen Existing Left (SK9 121.4 0.500 0.38 none none Bug Screen Existing Right (NE) 48.0 0.370 0.17 none none Bug Screen New Rear (N) 12.5 0.340 0.22 none none Bug Screen New Rear (NM 50.0 0.340 0.22 none none Bug Screen New Left (Kq 12.5 0.340 0.22 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 13.5 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Zone 1 - Master Suite Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing Zone 2 - Living Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing Zone 3 - Guest #1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20711:15:00 ID: 1 062511 Page 3 of 19 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 7/20/2011 Project Address 53960 Del Gato Drive La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,137 Addition 236 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 4.0 0.800 0.43 none none None Existing Skylight 4.0 0.800 0.43 none none None Existing HVAC SYSTEMS y. Heating Min. Eff Cooling Min. Eff Thermostat Status .0t 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Zone 4 - Guest #2/0frice Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING City. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: 1 062511 Pa e 4 of 19 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2011 SPECIAL FEATURES INSPECTION -CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details. A hot water recirculation systems has been modeled. Verification of type is required. The Existing Water Heater A O Smith Water Products FPSH-75 has an EF less than the Vintage Defaults. Field verification is required. The HVAC System Zone 1 -Master Suite must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be HIGH MASS Design - Verify Thermal Mass: 119.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 1,095.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite The HVAC System Zone 2 -Living must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,135.0 ft2 Exposed Slab Floor, 3.500" thick at Living HIGH MASS Design - Verify Thermal Mass: 207.0 ft2 Covered Slab Floor, 3.500 thick at Living HIGH MASS Design - Verify Thermal Mass: 236.0 ft2 Exposed Slab Floor, 4.000 thick at Wet Bar The HVAC System Zone 3 -Guest #1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 85.0 ft2 Exposed Slab Floor, 3.500" thick at Guest # 1 HIGH MASS Design - Verify Thermal Mass: 345.0 ft2 Covered Slab Floor, 3.500" thick at Guest # 1 HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.1 by EnerqySoft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: 1062511 Page 5 of 19 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System Zone 4 -Guest #2/0ffice must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be HIGH MASS Design - Verify Thermal Mass: 385.0 ftz Exposed Slab Floor, 3.500" thick at Guest # 2/0ffice HIGH MASS Design - Verify Thermal Mass: 530.0 ft' Covered Slab Floor, 3.500" thick at Guest # 2/0frice The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. R EnemvPro 5.1 by Ener Soft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: l 062511 Page 6 of 19 PERFORMANCE CERTIFICATE: Residential I(Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. Steve Wilson & Mrs. Barbara Wilson ❑ Multi Family m Existing+ Addition/Alteration 7/20/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 6.68 5.18 1.50 Space Cooling 94.21 91.38 2.84 Fans 21.11 20.34 0.77 Domestic Hot Water 6.59 6.59 0.00 Pumps 0.11 0.11 0.00 Totals 128.70 123.60 5.10 Percent Better Than Standard: 4.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE)135deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 1,722 388 Fuel Available at Site: Natural Gas (SlM 1,205 134 Raised Floor Area: 0 (NM 2,149 480 Slab on Grade Area: 5.137 (NE) 1,218 162 Average Ceiling Height: 12.4 Roof 5,137 8 Fenestration Average U -Factor: 0.48 TOTAL: 1.171 Average SHGC: 0.36 Fenestration/CFA Ratio: 22.8 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Santiago Lopez-Ocampo 7/10/2011 Address P.O. Box 1018 NameSantia o Lopez-Ocampo City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that complia ce using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building env ope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company "Design Mind Studio" Unique Residential De P Y Address 75-175 Merle Drive, Suite 200 Name Gordon Stein City/State/Zip Palm Desert, Ca 92211 Phone 1-(760) 773-4488 Sig d License # Date Ener Pro 5.1 by Enerqvsoft User Number: 5732 RunCode: 2011-07-20711:15:00 ID: 1 062511 Pa a 7 o 19 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type 0 Single Family ❑ Addition Alone [I Multi Family m Existing+ Addition/Alteration Date 7/20/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm I Tilt I Status 4 Location/Comments Slab 119 0.730 None 01 180 1 Existing 4.4.7-A1 Zone 1 - Master Suite Slab 1,095 0.730 None 0 180 Existing 4.4.7-A1 Zone 1 - Master Suite Wall 248 0.069 R-21 45 90 Existing 4.3.1-A6 Zone 1 - Master Suite Wall 198 0.069 R-21 135 90 Existing 4.3.1-A6 Zone 1 - Master Suite Wall 222 0.069 R-21 0 90 Existing 4.3.1-A6 Zone 1 - Master Suite Wall 149 0.069 1 R-21 315 90 Existing 4.3.1-A6 Zone 1 - Master Suite Wall 195 0.069 R-21 0 90 Existing 4.3.1-A6 Zone 1 - Master Suite Roof 1,214 0.025 1 R-38 0 18 Existing 4.2.1-A21 Zone 1 -Master Suite Slab 2,135 0.730 None 0 180 Existing 4.4.7-A 1 Zone 2 - Living Slab 207 0.730 1 None 0 180 Existing 4.4.7-A1 Zone 2 - Living Wall 129 0.069 1 R-21 45 90 Existing 4.3.1-A6 Zone 2 - Living Wall 187 0.069 R-21 0 90 Existing 4.3.1-A6 Zone 2 - Living Wall 450 0.069 R-21 315 90 xisting 4.3.1-A6 Zone 2 - Living Wall 369 0.069 R-21 1351 90 1 Existing 4.3.1-A6 Zone 2 - Living Door 32 0.500 None 1351 90 1 Existing 4.5.1-A4 Zone 2 - Living Door 24 0.500 None 1351 90 1 Existing 4.5.1-A4 JZone 2 - Living FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 4.0 0.500 NFRC 0.38 1 NFRC 45 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 2 Window 42.0 0.500 NFRC 0.38 NFRC 45 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 3 Window 6.0 0.500 NFRC 0.38 NFRC 0 Existing [Ej- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 4 Window 8.0 0.500 NFRC 0.38 NFRC 315 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 5 Window 8.0 0.500 NFRC 0.38 NFRC 315 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 6 Window 8.0 0.500 NFRC 0.38 NFRC 315 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 7 Window 8,0 0.500 NFRC 0.38 NFRC 315 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 8 Window 8.0 0.500 NFRC 0.38 NFRC 315 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 9 Window 48.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 10 Window 12.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 1 - Master Suite 11 Window 20.0 0.500 NFRC 0.38 NFRC 45 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 12 Window 56.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 13 Window 14.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 14 Window 56.0 0.500 NFRC 0.38 NFRC 0 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 15 Window 14.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 16 Window 56.0 0.500 NFRC 0.38 NFRC 0 Existing /E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len Ht 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Buq Screen 0.76 15 Bug Screen 0.76 16 16ug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: 1 062511 Page 8 of 19 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF-1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2011 OPAQUE SURFACE DETAILS Surface Type Area Ll- Insulation Joint Appendix Factor CavitYTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 142 0.069 R-21 180 90 Existing 4.3.1-A6 Zone 2 - Living Wall 200 0.069 R-21 225 90 Existing 4.3.1-A6 Zone 2 - Living Roof 2,342 0.025 R-38 0 18 Existing 4.2.1-A21 Zone 2 - Living Slab 236 0.730 None 0 180 New 4.4.7-A1 Addition Wall 64 0.069.R-21 45 90 New 4.3.1-A6 Addition Wall 49 0.069 R-21 0 90 New 4.3.1-A6 Addition Wall 103 0.069 R-21 315 90 New 4.3.1-A6 Addition Wall 49 0.069 R-21 270 90 New 4.3.1-A6 Addition Wall 112 0.069 R-21 225 90 New 4.3.1-A6 Addition Roof 232 0.025 R-38 0 18 New 4.2.1-A21 Addition Slab 85 0.730 None 0 180 Existing 4.4.7-A 1 Zone 1 - Guest # 1 Slab 345 0.730 None 0 180 Existing 4.4.7-A1 Zone 1 - Guest # 1 Wall 392 0.069 R-21 45 90 Existing 4.3.1-A6 Zone 1 - Guest # 1 Wall 229 0.069 R-21 225 90 X'sting 4.3.1-A6 Zone 1 - Guest # 1 Wall 216 0.069 R-21 135 90 Existing 4.3.1-A6 Zone 1 - Guest # 1 Roof 426 0.025 R-38 0 18 Existing 4.2.1-A21 JZone 1 - Guest # 1 FENESTRATION SURFACE DETAILS ID Type Area LI-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 14.0 0.500 NFRC 0.38 NFRC 0 Existing [E]- U. Value 0.58 -SHGC 0.38 Zone 2 - Living 18 Window 56.0 0.500 NFRC 0.38 NFRC 315 Removed (Ej- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 19 Window 14.0 0.500 NFRC 0.38 NFRC 315 Removed [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 20 Window 56.0 0.500 NFRC 0.38 NFRC 315 Removed [E]- U. Value 0.58- SHGC 0.38 Zone 2 - Living 21 Window 14.0 0.500 NFRC 0.38 NFRC 315 Removed [E]- U.Value 0.58 - SHGC 0.38 Zone 2 - Living 22 Window 39.0 0.500 NFRC 0.38 NFRC 315 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 23 Window 24.0 0.500 NFRC 0.38 NFRC 135 Existing (El- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 24 Window 6.0 0.500 NFRC 0.38 NFRC 135 Existing [E]- U. Value 0.58- SHGC 0.38 Zone 2 - Living 25 Window 28.0 0.500 NFRC 0.38 NFRC 135 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 26 Window 7.0 0.500 NFRC 0.38 NFRC 135 Existing (El- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 27 Window 56.0 0.500 NFRC 0.38 NFRC 135 Existing (El- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 28 Window 14.0 0.500 NFRC 0.38 NFRC 135 Existing (EJ- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 29 Window 28.0 0.500NFRC 0.38 NFRC 135 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 30 Window 7.0 0.500 NFRC 0.38 NFRC 135 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 31 Window 12.0 0.500 NFRC 0.38 NFRC 135 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 32 Window 12.0 0.500 NFRC 0.38 NFRC 135 Existing (EJ- U. Value 0.58 - SHGC 0.38 Zone 2 - Living (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade T H e SHGC t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len Hot Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bu Screen 0.76 32 ]Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: 1062511 Page 9 of 19 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type m Single Family ❑ Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 1712012011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments Slab 385 0.730 None 0 180 Existing 4.4.7-A1 Zone 4 - Guest # 2/01fice Slab 530 0.730 None 0 180 Existing 4.4.7-A 1 Zone 4 - Guest # 2/Office Wall 223 0.069 R-21 45 90 Existing 4.3.1-A6 Zone 4 - Guest # 2/01fice Wall 316 0.069.R-21 315 90 Existing 4.3.1-A6 Zone 4 - Guest # 2/Office Wall 482 0.069 R-21 225 90 Existing 4.3.1-A6 Zone 4 - Guest # 2/Office Wall 353 0.069 R-21 135 90 Existing 4.3.1-A6 Zone 4 - Guest # 2/Office Roof 915 0.025 R-38 0 18 Existing 4.2.1-A21 Zone 4 - Guest # 2/Office FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 28.0 0.500 NFRC 0.38 NFRC 180 Existing IE]- U.Value 0.58 - SHGC 0.38 Zone 2 - Living 34 Window 7.0 0.500 NFRC 0.38 NFRC 180 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 35 Window 56.0 0.500 NFRC 0.38 NFRC 180 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 36 Window 14.0 0.500 NFRC 0.38 NFRC 180 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 37 Window 28.0 . 0.500 NFRC 0.38 NFRC 180 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 38 Window 7.0 0.500 NFRC 0.38 NFRC 180 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 39 Window 20.0 0.500 NFRC 0.38 NFRC 225 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 40 Window 6.3 0.500 NFRC 0.38 NFRC 225 Existing (E]- U. Value 0.58 - SHGC 0.38 Zone 2 - Living 41 Window 48.0 0.370 NFRC 0.17 NFRC 45 New Sierra Pacific - Clad Door Addition 42 Window 12.5 0.340 NFRC 0.22 NFRC 0 New Sierra Pacific - Clad Wdw Addition 43 Window 12.5 0.340 NFRC 0.22 NFRC 315 New Sierra Pacific - Clad Wdw Addition 44 Window 12.5 0.340 NFRC 0.22 NFRC 315 New Sierra Pacific - Clad Wdw Addition 45 Window 12.5 0.340 NFRC 0.22 NFRC 315 New Sierra Pacific - Clad Wdw Addition 46 Window 12.5 0.340 NFRC 0.22 NFRC 315 New Sierra Pacific - Clad Wdw Addition 47 Window 12.5 0.340 NFRC 0.22 NFRC 270 New Sierra Pacific - Clad Wdw Addition 48 Skylight 4.0 0.800 NFRC 0.43 NFRC 0 Existing [E]- U. Value 0.80 - SHGC 0.43 Addition (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Buq Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Buo Screen 0.76 43 Buq Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 None 1.001 1 EnergyPro 5.1 by EnerqySoft User Number: 5732 RunCode: 2 01 1-0 7-2 0 711:15:00 ID: 1 062511 Pae 10 of 19 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Mr. Steve Wilson & MI's. Barbara Wilson Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/20/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit7vExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS Type Area U-Factor SHGC Azm Status GlazingType Location/Comments Window 48.0 0.500 NFRC 0.38 NFRC 225 Existing IEJ-U.Value0.58-SHGC0.38 Zone 1 - Guest # 1 F51 Window 14.1 0.500 NFRC 0.38 NFRC 225 Existing IEJ- U. Value 0.58 - SHGC 0.38 Zone 1 - Guest # 1 S light 4.0 0.800 NFRC 0.43 NFRC 0 Existing (E - U. Value 0.80 - SHGC 0.43 Zone 1 - Guest # 1 Window 48.0 0.500 NFRC 0.38 NFRC 45 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/0ffice 53 Window 6.0 0.500 NFRC 0.38 NFRC 315 Existing (EJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 54 Window 56.0 0.500 NFRC 0.38 NFRC 315 Existing (EJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/0ffice 55 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing (EJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/0ffice 56 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing IEJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/0ffice 57 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing IEJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 58 Wndow 15.0 0.500 NFRC 0.38 NFRC 225 Existing [E]- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/0ffice 59 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing /El- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 60 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing (E]- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 61 Window 3.0 0.500 NFRC 0.38 NFRC 225 Existing IEJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 62 Window 30.0 0.500 NFRC 0.38 NFRC 135 Existing IEJ- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office 63 Window 24.0 0.500 NFRC 0.38 NFRC 135 Existing IE]- U. Value 0.58 - SHGC 0.38 Zone 4 - Guest # 2/Office (1) U-Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat Wd Ove hanq Left Fin Right Fin Len Hat LExt RExt Dist Len Hat Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 None 1.00 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20T11:15:00 /D: 1062511 Page 11 of 19 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Building Type D Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 7/20/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ff New Existina Altered I Removed Volume Year Built Zone 1 - Master Suite Master Suite 1,214 15,054 2003 Zone 2 - Living Living 2,342 29,041 2003 Wet Bar 236 2,926 Zone 3 - Guest #1 Guest # 1 430 5,332 2003 Zone 4 - Guest #2/0ffice Guest # 2/Office 915 11,346 2003 Totals 1 2361 4,9011 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Zone 1 - Master Suite 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing Zone 2 - Living 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing Zone 3 - Guest #1 1 Central Furnace 80% AFUE Split Air Conditioner 13.5 SEER Setback Existing Zone 4 - Guest #2101fice 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Zone 1 - Master Suite Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing Zone 2 - Living Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing Zone 3 - Guest #1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing Zone 4 - Guest #2/Office Ducted I Ducted I Attic, Ceiling Ins, vented 4.21 ❑ Existin WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water Products 2 Large Gas Recirc/Time+Temp 80,000 74 0.78 0.00% 0.0 Existing MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) 0 is a Cn — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20711:15:00 ID: 1062511 Pae 12 of 19 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Date 7/20/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 S: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: Ig062511 Page 13 of 19 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. Steve Wilson & Mrs. Barbara Wilson 7/20/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porousinner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: lg062511 Page 14 of 19 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Mr. Steve Wilson & Mrs. Barbara Wilson 7/20/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC)'by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPr0 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20T11:15:00 ID: lg062511 Page 15 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Date 7/20/2011 System Name Zone 1 - Master Suite Floor Area 1,214 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 567 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 11,178 0 948 0 0 0 948 13,074 PEAK COIL HTG. PEAK Heating S stem Latent CFM Sensible Output perSystem 89,400 1,404 276 10,542 Total Output Btuh 89,400 Output Btuh/s ft 73.6 749 Cooling System Output erSystem 36,200 0 0 Total Output Btuh 36,200 1,404 Total Output ons 3.0 01204 Total Output Btuh/s ft 29.8 Total Output s ft/Ton 402.4 Air System CFM perSystem 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Lennox G40UH60C-110 - HS26-060 30,976 0 89,400 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 30,976 r 0 Aug 3P ml 89,400 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 105 OF Heating Coil 104 OF 1 ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76/63°F 76/63°F 55/54°F Cooling Coil -..-_.•I —ILI LI _ 56 / 54 OF 48.7% ROOM 75/62°F I EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2011-07-20711:15:00 ID: lg062511 Page 16 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Date 7/20/2011 System Name Zone 2 - Living Floor Area 2,578 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,912 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,400 36,624 2,956 825 31,084 Total Output Btuh 178,800 0 Output Btuh/s ft 69.4 3,106 2,208 Cooling System o 0 Output erSystem 36,200 0 0 0 0 Total Output Btuh 72,400 0 2,956 0 Total Output ons 6.0 1 3,106 2,208 Total Output Btuh/s ft 28.1 Total Output s ft/Ton 427.3 1 42,835 35,501 Air System CFM perSystem 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Lennox G40UH60C-110 - HS26-060 62,091 0 178,800 Airflow cfmis ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 62,091 0 178,800 Aug 3P ml Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 °F Outside Air 0 cfm 66 OF 66 OF 105 OF 91 Heating Coil 103 OF ............-- –._...— I ROOM II i 68 OF COOLING SYSTEM PSYCHROMETICS' Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 77/63°F 77/63°F 55/54°F Cooling Coil i 57 / 55 OF X48; s %ROOM 75/62°F EnergyPro5.1 by EnergySoft User Number. 5732 RunCode: 2011-07-20711:15:00 ID: lg062511 Page 17 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Date 7/20/2011 System Name Zone 3 - Guest #1 Floor Area 430 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 509 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 9,752 0 827 0 0 0 827 1 11,406 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 36,000 626 144 5,424 Total Output Btuh 36,000 Output Btuh/s ft 83.7 385 Cooling System 0 Output per System 17,900 0 0 0 Total Output Btuh 17,900 626 0 Total Output ons 1.5 385 Total Output Btuh/s ft 41.6 Total Output s ft/Ton 288.3 1 6,195 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Lennox G40UH24A-045 - HS26-024 15,405 0 36,000 Airflow cfm/s ft 0.00 Airflow cfmfron 0.0 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 15,405 0 36,000 Aug 3 PM I Jan 1 AM Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF Outside Air Ar 0 cfm 66 OF 66 OF 105 OF Heating Coil 103 OF .......... -- — ROOM 68 °F COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 77 / 63 OF 4 *1 77/63°F 55/54°F Cooling Coil – U— 4 57 / 55 °F 49.3% ROOM 75 / 62 OF 1 EnergyPro 5.1 by EnergySoR User Number: 5732 RunCode: 2011-07-20T11:15:00 ID: lg062511 Page 18 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. Steve Wilson & Mrs. Barbara Wilson Date 7/20/2011 System Name Zone 4 - Guest #2/Office Floor Area 915 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 704 Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 54,100 13,476 1,307 304 11,448 Total Output Btuh 54,100 0 Output Btuh/s ft 59.1 1,143 813 Cooling System 0 0 Output perSystem 20,400 01 0 0 0 Total Output Btuh 20,400 0 1,307 0 Total Output Tons 1.7 1,143 813 Total Output Btuh/s ft 22.3 Total Output s ft/Ton 538.2 1 15,762 1 13,074 Air System CFM perSystem 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Lennox G40UH36A-70X - HS26-036 17,551 0 54,100 Airflow cfm/s ft 0.00 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 17,551 0 54,100 Aug 3 PM Jan 1 AM Airflow cfm/Ton 0.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 66 OF 66 OF 105 OF Heating Coil 103 OF .............. -.__.-.-_.._ _ ..... ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 77 / 63 °F 77/63°F 55/54°F Cooling Coil 57 155 OF 49.3% ; ROOM 75 / 62 OF EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-07-20711:15:00 ID: lg062511 Page 19 of 19