Loading...
14-0718 (RR)P.O. BOX 1504 78-495 CALLE TAMPICO 7 LAQUINTA, CALIFORNIA 922 3 c&ht4-4Qub4 Application Number: 14-00000718 Property Address: 49280 AVENIDA FERNANDO APN: 658-280-019- - - Application description: RE -ROOF Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 18272 Applicant: Architect or Engineer: v BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Prof Is Code, and my License is in full force and effect. License C ss: C39 Cod No.: 868171 Date. 7 7 Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason ISec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. L'ender's Name: _ Lender's Address: LQPERAI IT Owner: MILLER TED 49280 AVENIDA FERNANDO LA QUINTA, CA 92253 ( VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/3054 Contractor: �D dam_'` FOAMBOND CORPORATION 255 N. EL CIELO STE 140-656 PALM SPRINGS, CA 92262 MAY (866)404-5440 LiC. No.: 868171 Iftiv— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier CA INS Policy Number 468463140101 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject o- workers' compensation provisions of Section 4700 of the Labor Code, I shallor Code, l shallforth c ply with those provisioply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMP SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above ' mation is correct. I agree to comply with all city and county ordinances and state laws relating to build' 'o ruction, and hereby authorize representatives of this cou ty to nter upon the above-mentioned pr inspection purposes. Date77W1, Signature (Applicant oren . Application Number .. . . . . 14-00000718 Permit . . . RE -ROOF Additional desc . Permit Fee . . . . 82.94 Plan Check Fee 00 .; Issue Date Valuation . . . . 0 Expiration Date 11/26/14 Qty Unit Charge Per Extension 1.00 48.620.0 LS MISC RE -ROOF, 1ST 2000 SF 48.62 3.100 11.4400 EA MISC RE -ROOF, ADDL 1000 SF , 34.32 ------------------------------------------------------------------------------ Special Notes and Comments RE -ROOF TEAR OFF EXISTINGFOAM ROOF SYSTEM INSTALL NEW POLYURETHANE FOAM SYSTEMWITH COATINGS & GRANILES CAPSHEET ROOF AREA WILL BE LEFT AS IS 2013CBC. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, RE -ROOF 97.24 , Fee summary Charged Paid Credited ----------------- Due ---------------------------------------- Permit Fee Total 82.94 .00 .00 82.94 Plan Check Total .00 .00 .00 .00 Other Fee Total 98.24 .00 .00 98.24 Grand Total 181.18 .00 .00 181.18 t LQPERn11T Bin # K, City of La Q uin to -Building 8t• Safety Division P.O. Box 1504,.78-4 95 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: Z `f Owner's Name: A. P. Number: Address: Mffo AVu„J e d Leges] Description: City, ST, Zip:. Contractor: �va- / do'x d�0� Telephone: Address: zs$ k.: , 5-.1.% � 16 Project Description: �n rs, City, ST, Zip: S eA sLeti Telephone: �6(i _G�/O - �'�i�I�f�. /7 a tr t, % v t' �� �v �+t.•a ✓eo State Lie. # City Lie. #: S t•; � w i..�L L' O a'{ia S n at Arch., Engr., Designer: 01 e, 0-t; . a d' Address: / City, ST, Zip: Telephone: '"'` .•:<::,;r<:; :<;::>:;>;#::;;<<v;;:«:;::;v; Construction Type: Occupancy: State Lie. #: Project type (circle one): New Add'.n Alter Repair Demo Name of Contact Person: Sq. Ft.: Stories: #Units: Telephone *,of Contact Person: o Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES. Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cala. Called Contact Person Plan Check Balance_ Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2*' Review, ready for corrcctionslissue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE: '"' Reyiew, ready for corrcctionsCssue Developer Impact Fee Planning App rovalCalled Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fccs 7 FPrescriptive Certificate of Compliance: Residential Reroof CF-IR-ALT-ReRoof Project Address: Climate Zone . Permit # -ZO0. /T✓Zr-t�C /ed/tac-Glp rROOFING PRODUCTS (COOL ROOFS) §151(012 I When the area of exterior roof surface to be replaced exceeds 50% of the existing roof area, or 1,000 ft, whichever is less, the new roofing area must meet the roofing product "Coot Roof' requirements of §152(b)1 Hi, 152(b)1 Hii, or 152(b)1 Hfii. Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof" requirements:, ❑ Cool roofs not required in Climates Zones 1-12,14, and 16 with a low sloped roof pitch (less or 2:12 pitch). ❑ Cool roofs not required in Climates Zones 1-9, and 16 with a steep -sloped roofs (greater pitch than 2:12) and product weightless than 5AW. Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch> 2:12) ❑ Insulation with a thermal resistance of at least 0.85 hrft2.'FBtu or at least a 3/4 inch air -space is added to the roof deck over an attic; or ❑ Existing ducts in the attic are insulated and sealed according to §151(010; or ❑ In climate zones 10, 12 and 13, with 1 ft2 of free ventilation area of attic ventilation for every 150 fe of attic floor area, and ere at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or Building has at least R-30 ceiling insulation; or ❑ Building has radiant barrier in the attic meeting the requirements of §151(f)2; or ❑ Building has no ducts in the attic; or ❑ In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic. Exception to §152(b)l Hiii, Low -slope roof ( pitch <_ 2:12) ❑ Building has no ducts in the attic. Other Exceptions ❑ Roofing area is covered by building integrated, photovoltaic panels and solar thermal panels are exempt from the Cool Roof criteria. ❑ Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/ft2 are exempt from the Cool Roof criteria. any one of the alternatives or exception is checked the Aged Solar Reflectance products in §118(t) are not applicable. Do not fill table below. NOTE: When a Cool Roof is required, the installing contractor shall complete and submit the CF -6R -ENV -01 for final inspection. Declaration Statement Roof Slope Product Weight Product Aged Solar Thermal CRRC Product ID Number' <_. 2:12 > 2:12 < 5lb/ft2 ->_ 516ff Type 2 Reflectance 3,4 Emittance SRI Address: �71S'5" A), i:_( 4 e l o00 1 ❑ Phone: f /6/ VO y-S_YC10 ❑ ❑ 1.-4..J : ❑4 �6 _54 . ❑ ❑ ❑ ❑ ❑4 , Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.9M6LMductslsearch.nho 2. Indicate the type of product is being used for the roof top, i.e. single7ply roof asphalt roof, metal roof, etc. 3. If the.Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same --direct ry-and use ifre-equation Yfi2rp l(p;,b;, — 0. o o am a cu a ag va ue. re p �s t e nK�a olar eHedance. Check box if the Aged Reflectance is a calculated value using the equation above. . Calculate the SRI value by using the SRI- Worksheet at httpYAvww.eneray.ca.aovlWtle241 and enter the resulting value in the SRI Column above and attach atopy of the SRI- Worksheet to the CF -1R. o apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating ❑ Cement -Based Roof Coating ❑ Other NOTE: When a Cool Roof is required, the installing contractor shall complete and submit the CF -6R -ENV -01 for final inspection. Declaration Statement • I certify under penalty of perjury, under the laws of the State of Calitomia, the information provided on this form is accurate and complete. • 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. Name: Signature: Company:/ �,o a, 110'.4 Date: 5 3 0 B Address: �71S'5" A), i:_( 4 e l License: 'PO/3� . . /State/Zip: s c� . Phone: f /6/ VO y-S_YC10 FoMssistance or questions regarding. the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. HO O A -M N D FOAM ROOFS AND WALL INSULATION 255 N. E1 Cielo Ste. 140-656 Palm Springs, CA 92264 Phone (909) 841-0676 Fax (760) 398-5440 PROPOSAL AND CONTRACT Contractor: FoamBond Corporation Buyer: Ted Miller Job Address: 49280 Avenida Fernando La Quinta, CA Telephone: 503-544-3086 Lic. 868171 C-39 FOAMBOND proposes to install a urethane foam roofing system at the above noted address in accordance with the following detailed specifications on 4,543 sq. ft of existing foam roof. TEAR OFF SPECIFICATIONS: PREPARATION: 1. Remove existing roofs down to wood substrate, on re -roof area (app 2300 sq feet) 2. Open all drains and scuppers, make sure all drains are not_clogged.. 3. Replace damaged plywood and dry rot as needed at $1.85 a foot 4. Install blocks under all conduit and water lines 5. Extend roof jacks as required to accommodate new urethane foam roof 6. Install new 24 GA drip edge metal 7. Prime entire roof deck at t gallon per 250- sq. ft. 8. Mask all areas not to receive the foam application (walls, A/C's, etc.) URETHANE FOAM APPLICATION: 9. Spray/apply a minimum of 1" of 2.7 to 3.0 lb. nominal density foam to entire roof deck and parapet walls, spray foam will be built up and sloped toward scuppers/drains 10. Add foam build-up.in.low areas. to -improve- severely pond conditions 11. Grind foam at drains/runoff areas to promote proper drainage 12. Terminate foam near top of exposed Z -metal on roof to wall transitions COATING APPLICATION: 13. Apply acrylic elastomeric caulking at roof penetrations as a secondary sealant on top of the foam application 14. Apply a high solids elastomeric acrylic gray basecoat at 1-1/2 gallons per 100 sq. ft. 15. Apply a high solids elastomeric acrylic white topcoat at 1-1/2 gallons per 100 sq. ft. 16. Add fire white ceramic roofing granules at 40 lb per 100 square feet FINAL WORK: 17. Remove all masking materials and over spray protection 18. Remove all job related trash from job site 19. Perform a final job walk with the Owner of Owner's representative WARRANTY: 20. FoamBond warranties all labor and materials for a period of ten years on foam roof areas only. Warranty is renewable at the end of the term. Price and payment terms: 10% upon contract acceptance. Balance due on job completion. 4 ffO A M N D TOTAL PRICE FOR THIS SCOPE OF WORK IS: $ 18,272.00 FOAM ROOFS AND WALL INSULATION Approved and Accepted by Owner: Name er 3-27-14 v y Date t FoamBond Representative