10-0445 (AR)4 P O. BOX 1504 VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA,.CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 8/18/10
Application Number: 10-00000445 Owner:
Property Address: 76985 AVENIDA FERNANDO MCKENNA MAX & SUSANr�l n fl
APN: 658-240-035= - - 76985 AVENIDA FERNANDO
Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL AU,
::J 1 J
Application valuation: 30000 `!
Contractor: + "' f;i'i'r's+l1A
Applicant: Architect or Engineer. RAM DEVELOPMENT & CONST CO�I�C""''--"�==
72048 WOBURN COURT
THOUSAND PALMS, CA 92276
C ro� �G• (wlN ��
(760)343-1800
Lic. Noo..:: 529976
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 529976
Jl Date��—J/l� Contractor:
• OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 ) 1 am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier ASSURANCE CO Policy Number WC0310578201
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
Q Q 3700 of the Labor Code, I shall fort ith comply with those provisions.
pate+—'y-'L0 Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that 1 have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to/ enter upon the above -mention re erty for inspe tion purposes.
Oate:�t_w Signature (Applicant or Agent):
Application Number . . . . . 10-00000445
------ Structure Information 105SF ADD+REM/VB/RES-3/CLASS A -FR [ENG] -----
Other struct info . . . . . CODE EDITION 2007/2008
FLOOD ZONE NO
1ST FLOOR SQUARE FOOTAGE 105.00
----------------------------------------------------------------------------
Permit . . .
Additional desc . .
Permit Fee . . . .
Issue Date . . .
Expiration Date . .
BUILDING PERMIT
284:50
2/14/11
Plan Check Fee . . 184.93
Valuation . . . . 30000
Qty Unit Charge Per Extension
BASE FEE 252.00
5.00 6.5000 THOU BLDG 25,001-50,000 32.50
----------------------------------------------------------------------------
Permit . . . ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . 18.68
Issue Date . . . .
Expiration Date . . 2/14/11
Plan Check Fee . . 4.67
Valuation . . . . 0
Qty Unit Charge Per Extension
BASE FEE . 15.00
105.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3.68
----------------------------------------------------------------------------
Special Notes and Comments
105SF ADDITION & REMODEL AT DINING
ROOM/VB/RES-3/CLASS A -FR [ENGINEERED]
THIS PERMIT DOES NOT INCLUDE MECHANICAL
OR PLUMBING INSTALLATIONS. 2007/2008
CALIFORNIA BUILDING CODES.
August 18, 2010 12:38:44 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00
ENERGY REVIEW FEE 18.49
STRONG MOTION (SMI) - RES 3.00
Fee summary Charged
Permit Fee Total 303.18
Plan Check Total 189.60
Other Fee Total 23.49
.Grand Total 516.27
LQPERMIT
Paid Credited Due
.00 .00 303.18
.00 .00 189.60
.00 .00 23.49
.00 .00 516.27
\t�
Bin #L
i�
Qty Of . a QLuinta
Building 8i Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
�i
Project Address: 7Co - $ V�� p� -(gyp Downer's Name: 0, JS P !'► �� N NP.
A. P. Number: Address: -76-05 N46 !I (PA V:t—,-W 0N0 Q
Legal Description: City, ST, Zip: LA Out t-rf-,p, 61 22.53
z
Contractor: eV L'r � P pie- Telephone: s
�rc3rySzzs;,a..•o>r�:r ,. c�3
Address: %Z,•40 LI 16 wo& v2,,r�1 c z R, Project Description: Expct
City, ST, ZiplU-50-� D kct�,L+M--, CI, g221(-
Telephone: 116V • 343 180G
`f ,,lf '`�:'>::£�'�,�
State Lic. # : $
City Lic. C
Arch.,LE� Designer.
Address: 141-190 C ,t11,T6 2p
City., ST, Zip: khx-4" "/Zr- CIA a 22 1 l
` Yrsti''r.{(
:�
CTele hone: 6U SGS3 onstruction Type: Occupancy:
State Lic. #: .,i.Project tYPa (circle one): New Alter Repair Demo
Name of Contact Person: ?6�--% 69z,%J. Sq. Ft.: 1&4 -cit # Stories: # Units:
Telephone # of Contact Person: Estimated Value of Project: S -O
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACIUNG PERMIT FEES
Plan Sets
Plan Check submitted 3 Item Amount
Structural Calcs.
��
Reviewed, ready for corrections Plan Check Deposit
Truss Calcs.
Called Contact Person 160 Plan Check Balance.
We 24 Calcs.
Z
Plans picked up 10 Construction
Flood plain plan
Plans resubmitted 'Z Mechanical
Grading plan
2s0 Review, readyf orrec ' ue Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up N'( S.M.I.
H.O.A. Approval
Plans resubmitted //p Grading
IN HOUSE:-
'^' Review, ready for correction iss 1 Developer Impact Fee -..,
Planning Approval
Called Contact Person 8 18 .I.P.P. lu
Pub. Wks. Appr
Date of permit Issue
School Fees
i
w
t V
Total Permit Fees K
b/to G.cw ,Q�'� �ou�1 ;Gam. fi l - r
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road Q BERMUDA DUNES O
&n RANCHO MIRAGE
Date 6/23/10 La Quinta, CA 92253 J INDIAN WELLS
Vi PALM DESERT ,y
No. 30736 (760) 771-8515 LAIN
INTA
'Q Ij 0 y�
0
Owner
Max & Susan McKenna
APN # 658-240-035
Address
76-985 Avenida Fernando
Jurisdiction La Quinta
City
La Quinta Zip 92253
Permit #
Tract #
No. of Units
Type
Residential Addition
Lot # No. Street S.F.
Lot # No. Street S.F.
Unit 1
76985 Avenida Fernando 105
Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 105 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By N/A -Rusty Woods Check No. N/A
Name on the check Telephone
Funding Exempt
By Dr. Sharon P. McGehee �{
Superintendent --
Fee collected /exempted by Yolanda Garcia Payment Recd 50.00:7
Over/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above Will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy- Applicant/Receipt Copy - Accounting
AP_pg_0rderListApprova1 Page 1 of I
COMMERC IAL',WARRANTIcORDER-,LISTtAPPROVAL
4We the undersigned,,,as,members, of/lauthoriied -agent for; the,g0veihi' 06ard!�Ohe',",.,
'
flg�
Z4Z,, !f3f,4,
DESERT SANDS UNIFIED SCHOOL DISTRICT of RIVERSIDE COUNTY, California, by
signature hereto, approve each, every and all of the attached order(s),
WZC".
-05
om. To:
Number(s) 158832 158868
37 orders in the amount of $86,816.88
Excluding: I"
M
"o,
om-'.
,in the total`amobht'6f,'.$86;916:88,"-,:*C,),.rqt;.A ;"I!a
4!.*r.J��N%.:i'.0 0 � 0 !T 14
6W4-,'3§"proper le'gal'charges,leigainsttthefunds of the: Dis.trict-as indicated- above.
The undersigned certifies that all orders have,been processed by the School District in accordance
with the School District's systerr�of internal'&66&6_1s;and currently-accie^otibd audit'dridelines for the
0uO, expenditures ofthe School District,funds..
j
V1
Date: 05/24/2010
Governing Board rribeqtPkthorized Agent
UW L Governing Board Member
Governing Board Member
County qffice.,V se Only:
Int V
jt)t Reviewe-d,and Audited, by: oti:,
S,
C.�
'Ilk
Reviewer's i�U6 Date
t;
Examined Approved and Allowed
Kenneth M.Young
Riverside County Superintendent of Schools
Deputy
J.111017 -J
http://galaxy.reoe.kl2.ca.us/Galaxy/Silver.Stream/Pages/AP_pg_OrderListA... 5/24/2010
FIA! DESERT RESORT MANAGEMENT
April 30, 2010
Michael & Susan McKenna
76-985 Avenida Fernando
La Quinta, CA 92253
RE: Architectural Variance / Los Estados @ Santa Rosa Cove H.O.A.
Dear Mr. & Mrs. McKenna,
This is to inform you the Design Review Committee for Los Estados Homeowne "",
Association met to review your Architectural Application and submittal dated April
26, 2010 for the following:
1. To add approx 104.91 sq. ft. (3 ft. wide 21 ft. 6 inches long) south side
extension,.and the at the eastern golf course side expansion which will be
,-
,no nearerto.lhe go.lf;7courseep-roperty line than `N , existing main room per
:plansaubrnitted�and�dated 4/19/10=byB:G` structural`Engirieering
specifically Floor PlansW-I='which shows`the='expansion -and' elevations.
2. Committee/Board notes reflect'that the adjoining neighbor at 76975
Avenida' Fernando on 4/26/10'has submitted their written approval of this
project.
After due consideration the Architectural Committee has, approved your
application contingent on the following items:
1. Owner must obtain all permits through City of La Quinta; and required
inspections by the City and State code.
2. Owner agrees to ensure that the contractor keeps the streets, gutters and
adjacent properties clean and free of dirt, trash, debris or other material
related to or caused by the work and clean up of all street spills on a daily
basis.
3. Constructionhours are•Monday through Friday from 8:00 AM,– 5:_00 PM
4. Owner mill be. held responsible for aany road damaged caused bye,.-
contractors work orwehicles" We strongly recommend use of plywood
sheets_under;roofmaterials or stockpiies"on tl e''road-as'ne'eded-to protect
the road'surface: ' This ,is`especially -important' during ,thispenod of '
extreme5heat:
42-635 Melanie Place, Suite 103 • Palm Desert, CA 92211
P.O. Box 14387 • Palm Desert, CA 92255-4387
760.346.1161 • FAX 760.346.9918
Email: drm@drminternet.com • www.drminternet.com
McKenna
Page 2
4/30/10
5. Owner agrees to submit the Notice of Completion form at the end of the
project.
If you have any questions please call me at (760) 346-1161. Thank you for your
patience during the review process.
Si e ely,
Carol Calhoun, CCAM@
Community Association Manager
For the Design Review Committee
Los Estados @ Santa Rosa Cove H.O.A.
Cc: Board of Directors/Architectural Committee
Los Estados @ Santa Rosa Cove Homeowners Association
Notice of Completion Form
Homeowner Name:
Address:
Phone:
Summary of Completed Improvements
Cell:
Attachments (check box to indicate they have been enclosed):
Copies of photographs of all improvements included. Please note that notice of
completion form is not complete if photographs of improvements are not
enclosed.
Request to receive $4,500 refundable construction deposit after Committee has
completed Final Inspection.
Signature:
Date:
By signing this form, the homeowner is stating that improvements completed have been
completed in accordance to the scope and specification of the approved architectural
application and in accordance with the community's architectural guidelines.
Los Estados @ S.R.C. Homeowners Association
c/o Desert Resort Management
P.O. Box 14387, Palm Desert, CA 92255
(760) 346-1161 Fax (760) 346-9918
ccalhoun@drminternet.com
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
McKenna Residence
76-985 Avenida Fernando
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montana Road, Suite 210
Palm Desert, Ca 92211
760-345-1352
RECEIVED
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE
BY,
AUG 10 2010
BY:
Job Number:
Date:
8/10/2010
nP.*wA pou Aw*o4I W,
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
EnergyPro 5.0 by EnergySoft Job Number: ID: User Number: 2655
1
2
3
10
13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
McKenna Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/10/2010
Project Address
76-985 Avenida Femando La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,223
Addition
104
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
.❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Wall Wood Framed
R-11 1,028 Existing
Door Opaque Door
None 24 Existing
Roof Wood Framed Attic
R-19 2,119 Existing
Slab Unheated Slab -on -Grade
None 2,119 Perim = 410' Existing
Roof Wood Framed Attic
R-38 104 New
Wall Wood Framed
R-19 195 New
Slab Unheated Slab -on -Grade
None 104 Perim = 12' New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (M 51.0 0.710
0.73 2.0 none Bug Screen Existing
Front (W) 12.4 0.710
0.73 2.0 none Bug Screen Existing
Front (W) 12.4 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 10.5 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 31.5 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 36.0 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 63.0 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 68.0 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 8.0 0.710
0.73 2.0 none Bug Screen Existing
Right (S) 10.5 0.710
0.73 2.0 none Bug Screen Existing
Right (S) 9.0 0.710
0.73 2.0 none Bug Screen Existing
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPry 5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-10T11:27:2 ID:
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
McKenna Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/10/2010
Project Address
76-985 Avenida Fernando La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,223
Addition
104
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(fo Factor
Exterior
SHGC Overhang Sidefins Shades Status
Right (S) 64.0 0.710
0.73 2.0 none Bug Screen Existing
Right (S) 20.6 0.710
0.73 2.0 none Bug Screen Existing
Right (StM 18.7 0.710
0.73 2.0 none Bug Screen Existing
Front (NKK 18.7 0.710
0.73 2.0 none Bug Screen Existing
Front (lAq 21.0 0.550
0.45 2.0 none Bug Screen New
Rear (E) 22.0 0.550
0.45 2.0 none Bug Screen New
Rear (E) 64.0 0.550
0.45 2.0 none Bug Screen New
Right (S) 43.8 0.550
0.45 2.0 none Bug Screen New
Right (S) 42.0 0.710
0.73 2.0 none Bug Screen New
Right (S) 43.8 0.550
0.45 2.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro5.0byEnergySoft User Number: 2655 Run Code: 2010-08-10T11:27.2 /D:
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
McKenna Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1811012010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with -the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnerqyPro 5.0 by EnerqySoft User Number: 2655 RunCode: 2010-08-10T11:27:2 /D: Page 5 of 13
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
McKenna Residence
1 ❑ Multi Family m Existing+ Addition/Alteration
8/10/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 12.40 10.89 1.51
Space Cooling 197.48 198.78 -1.30
Fans 42.98 43.18 -0.20
Domestic Hot Water 17.36 17.36 0.00
Pumps 0.00 0.00 0.00
Totals 270.22 270.22 0.01
Percent Better Than Standard: 0.0
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (tM 432 116
Fuel Available at Site: Natural Gas (N) 766. 217
Raised Floor Area: 0 (E) 150 86
Slab on Grade Area: 2,223 (S) 570 252
Average Ceiling Height: 9.0 Roof 2,223 0
Fenestration Average U-Factor: 0.66 TOTAL: 671
Average SHGC: 0.65 Fenestration/CFA Ratio: 30.2%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company /nsu-form, Inc.
8/102010
Address 77-810 Las Montana Road, Suite 210 Name Joan D. Hacker thal
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company
Address Name
City/State/Zip Phone Signed License # Date
EnemyPro 5.0 by EnerqySoft User Number: 2655 RunCode: 2010-08-10T11:27:2 /D: Page 6 of 13
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
McKenna Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1811012010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
140
0.110 R-11
270
90 Existing 4.3.1-A2
Existing Living
Door
24
1.450 None
270
90 Existing 4.5.1-A1
Existing Living
Wall
278
0.110 R-11
0
90 Existing 4.3.1-A2
Existing Living
Wall
271
0.110 R-11
0
90 Existing 4.3.1-A2
Existing Living
Wall
2561
0.110 R-11
180
90 Existing 4.3.1-A2
Existing Living
Roof
2,1191
0.049 R-19
270
0 Existing 4.2.1-A4
Existing Living
Slab
2,1191
0.730 None
0
180 Existing 4.4.7-A 1
Existing Living
Wall
330
0.110 R-11
90
90 Remove 4.3.1-A2
Existing Living
Wall
340
0.110 R-11
180
90 Removec 4.3.1-A2
Existing Living
Wall
41
0.110 R-11
225
90 Existing 14.3.1-A2
Existing Living
Wall
41
0.110 R-11
315
90 Existing 4.3.1-A2
Existing Living
Roof
104
0.025 R-38
0
0 New 4.2.1-A21
Addition
Wall
111
0.074.R-19
270
90 New 4.3.1-A5
Addition
Slab
1041
0.730 1 None
0
180 New 4.4.7-A1
Addition
Wall
641
0.074 R-19
901
90 New 4.3.1-A5
Addition
Wall
201
0.074 R-19 1
1801
90 1 New 4.3.1-A5
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
42.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
2
Window
9.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
3
Window
12.4 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
4
Window
12.4 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
5
Window
10.5 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
6
Window
31.5 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
7
Window
36.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
8
Window
63.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
9
Window
68.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
10
Window
8.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
11
Window
45.5 0.710 Default
0.73 Default
0 Removed Double Metal Clear
Existing Living
12
Window
10.5 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
13
Window
9.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
14
Window
64.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
15
Window
21.0 0.710 Default
0.73 Default
180 Removed Double Metal Clear
Existing Living
16
Window 1
42.0 0.710 Default
0.73 Default
180 Removed Double Metal Clear
Existing Living
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
7.0 6.0
2.0 0.1
2.0 2.0
2 •
Bug Screen
0.76
3.0 3.0
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
5.4 2.4
2.0 0.1
2.0 2.0
4
Bug Screen
0.76
5.4 2.4
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
7.0 1.5
2.0 0.1
2.0 2.0
6
Bug Screen
0.76
7.0 5.2
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
7.0 5.2
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
7.0 9.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
8.5 8.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
1.0 8.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
7.0 6.5
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
7.0 1.5
2.01 0.1
2.0 2.0
13
Bug Screen
0.76
6.0 1.5
2.0 0.1
2.0 2.0
14
Bug Screen
0.76
8.0 8.0
2.0 0.1
2.0 2.0
15
JBug Screen
0.76
7.0 3.0
2.0 0.1
2.0 2.0
16
IBug Screen
0.76
7.0 6.0
2.0 0.1
2.0 2.0
EnergyPro
5.0 by EnergySoft User Number: 2655
RunCode: 2010-08-10T11:27:2 ID:
Page 7 of 13
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
McKenna Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1811012010
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame . Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
LI -Factor
SH C2
Azm Status Glazing Type Location/Comments
17
Window 20.6
0.710 Default
0.73 Default
180 Existing Double Metal Clear Existing Living
18
Window 18.7
0.710 Default
0.73 Default
225 Existing Double Metal Clear Existing Living
19
Window 18.7
0.710 Default
0.73 Default
315 Existing Double Metal Clear Existing Living
20
Window 21.0
0.550 NFRC
0.45 NFRC
270 New IWC 6200 Alum/Low-E Addition
21
Window 22.0
0.550 NFRC
0.45 NFRC
90 New IWC 6200 Alum/Low-E Addition
22
Window 64.0
0.550 NFRC
0.45 NFRC
90 New IWC 6200 Alum/Low-E Addition
23
Window 43.8
0.550 NFRC
0.45 NFRC
180 New IWC 6200 Alum/Low-E Addition
24
Window 42.0
0.710 Default
0.73 Default
180 New Double Metal Clear Addition
25
Window 43.8
0.550 NFRC
0.45 NFRC
180 New IWC 6200 Alum/Low-E Addition
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
4.0 5.2
2.0 0.1 2.0 2.0
18
Bug Screen
0.76
7.0 2.8
2.0 0.1 2.0 2.0
19
Bug Screen
0.76
7.0 2.8
2.0 0.1 2.0 2.0
20
Bug Screen
0.76
7.0 3.0
2.0 0.1 2.0 2.0
21
Bug Screen
0.76
7.0 3.2
2.0 0.1 2.0 2.0
22
Bug Screen
0.76
8.01 8.0
2.0 0.1 2.0 2.0
23
Bug Screen
0.76
7.01 6.3
2.0 0.1 2.0 2.0
24
Bug Screen
0.76
7.0 6.0
2.0 0.1 2.0 2.0
25
Bug Screen
0.76
7.0 6.3
2.0 0.1 2.0 2.0
EnergyPro
5.0 by EnergySoft
User Number: 2655
RunCode: 2010-08-10T11:27:2 ID: Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
McKenna Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1811012010
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
Living Zone Existing Living
2,119
19,071 1987
Addition
104
832
Totals 1041 Z1191 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone
2 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
L—+
WATER HEATING SYSTEMS
S stem Name
Qty-
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.53 n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
E'
w a-
Hot Water Piping Length
ft
o
.r
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
LEnePr�o�5.�O byEnem
Soft
User Number: 2655
Run Code: 2010-08-10T11:27.2 ID:
Page 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
McKenna Residence
Date
1 8/10/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. 1
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fire laces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
P
EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-10711:27:20 /D: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
McKenna Residence
1811012010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-10T11:27:20 /D: Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
McKenna Residence
8/10/2010
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2:.Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro5.0 by EnergySoft User Number: 2655 Run Code: 2010-08-10T11:27:20 ID: Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
McKenna Residence
Date
8/10/2010
System Name
Living Zone
Floor Area
2,223
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 3,533
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 56,000
50,207
3,171 1,487
51,102
Total Output Btuh 112,000
0
Output Btuh/s ft 50.4
5,597
4,448
Cooling System
01
0
Output per System 42,000
0
0 0
0
Total Output Btuh 84,000
0
3,171
0
Total Output Tons 7.0
5,597
4,448
Total Output Btuh/s ft 37.8
Total Output s fUTon 3176
1 61,401
59,998
Air System
CFM per System
1,500
HVAC EQUIPMENT SELECTION
Airflow cfm
3,000
Exist 53,832
24,206
112,000
Airflow cfm/s ft
1.35
112,000
Jan 1 AM
Airflow cfm/Ton 428.6
Outside Air % 0.0 %
Total Adjusted System Output 53,832
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK
24,206
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air
'0 cfm Supply Fan
Ak 3,000 cfm
69 OF
69 OF 104 OF
-
Heating Coil
102 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 80168 OF 80 / 68 OF 63 / 62 OF
Outside Air Ar
0 cfm Supply Fan Cooling Coil 65 / 62 OF
3,000 cfm 57.4% ROOM In
80 / 68 OF 78 / 67 OF
EnergyPro 5.0 by EnergySoft
User Number: 2655 Run Code: 2010-08-10711:27:20 /D:
Page 13 of 13