Loading...
14-0451 (RR)4 P.O. BOX 1504 ^' VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/16/14 Application Number: 14-00000451 Owner: Property Address: 77000 AVENIDA FERNANDO DOUG LONG APN: 658-240-013- - - 77000 AVENIDA FERNANDO Application description: RE -ROOF LA QUINTA, CA 92253 D n Property Zoning: LOW DENSITY RESIDENTIAL ( (� Application valuation: 29772 p cy Contractor: APR t 5 2@114 A ipanvxlla� Architect or Engineer: WINKLE COMPANY, R.D. P.O. BOX 476 C F r OF LA QUINTA CSC/ THOUSAND PALMS, CA 92276 �rtif4.:�� i)p1. (760)322-5144 Lic. No.: 688062 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C39 C46 LicenseNV 688062 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of erjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State . License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) .1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law3. ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000182-2014 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of th ✓1Je Labor Co , I shall forthwith comply wi h those provisions. Date l t+ / V ' Applicant: WARNING: FAILURE TOS WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property f inspection purposes. Date: 0 `� Signature (Applicant.or Agent): Application Number Permit . . . Additional desc . . Permit Fee . . . . Issue Date . . . . Expiration Date . . . . . . 14-00000451 RE -ROOF 71.50 Plan Check Fee . . .00 Valuation . . . . 0 10/13/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC RE -ROOF, 1ST 2000 SF 48.62 2.00 11.4400 EA MISC RE -ROOF, ADDL 1000 SF 22.88 ---------------------------------------------------------------------------- Special Notes and Comments RE -ROOF NEW 60 MIL THERMOPLASTIC (TPO) ROOFING .SYSTEM WITH 1" EPS INSILATION THE EXISTING ROOF IS TO BERECOVERED. THE NEW ROOF SYSTEM WILL BE MECHANICALLY FASTENED TO 1-90 SPECS. 2013 CBC. ---------------------------------------------------------------------------- Other Fees . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, RE -ROOF 97.24 Fee summary Permit Fee Total Plan Check Total Other Fee Total Grand Total LQPERMIT Charged Paid Credited Due 71.50 .00 .00 71.50 .00 .00 .00 .00 98.24 .00 .00 98.24 169.74 .00 .00 169.74 The Long Residence 77000 Avenida Fernando La Quinta, CA. 92253 Attn: Mr. Doug Long Wednesday, April 2, 2014 Re: Thermoplastic Polyolefin (TPO) Roofing System with V EPS Insulation This proposal is in regard to the above referenced project. We are proposing to supply and install a new Thermoplastic Polyolefin (TPO) roofing. system with 1" EPS insulation. Furnishings and installations will be as explained below; Surface Preparation's Demolition & Clean Up: RDW will remove the gravel surface from the low -slope roofing system. This will give a cleaner surface for the preparations of the new roofing system and will ensure the new materials will not be punctured. All debris on the ground will be swept up and the grounds will be rolled with a magnet to pick up any fasteners and or metal scraps that had fallen during the demolition. RDW will dispose of all roofing waste. Low -Slope Roofing Systems Thermoplastic Polyolefin (TPO) Roofing System Board Insulation: RDW will supply and installed a single layer of I" rigid EPS board insulation. The board insulation will overlay the existing built-up roof. By overlaying the existing built-up roof the waste.will be minimized and the new roofing system will maintain a class "A "fire rating. The EPS will provide a smooth surface for the new roofing system and will give additional insulation of approximately R-6 aged value RDW will. mechanically fasten the insulation to the substrate using 3" plates and 2" fasteners. The fasteners will be installed in an I-90 pattern giving a 90mph wind rating. Additional insulation will be added to standing water areas. This will help reduce standing water, not eliminate it. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 Thermoplastic Polyolefin (TPO) Roofing System (continued) Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing system. We will be installing a 60mil-reinforced membrane that will be 8' or 10' by 100' roll. This allows us to have less field seams and end lap seams. than your typical built-up roofs. This is a sure weld membrane meaning that all seams are heat welded together, compared to either hot tar in a built up roof or an open flame used in torch on roofs. The field will be seamed with a robotic heat welder giving a continuous and consistent weld Details, such 'as flashings and corners will be welded by hand. Welds will then be checked with a probe. The product is much safer, cleaner, and does not produce any unpleasant odor when being installed Other positives to this roofing system are that the TPO membrane is highly reflective and helps reduce energy consumption cost, it will provide a long term resistance to the punishing ultraviolet rays we receive here in the western states. This system meets California Title 24 specifications. The TPO roofing system will be installed to the manufactures specifications. This roofing system meets the specifications for a Manufacture 20 year No Dollar Limit (NDL) Warranty. Sheet metal: RDW will supply and install the following TPO coated sheet metal; edge metal, T -Top vents and scuppers. If other sheet metal is desired to be. installed by RDW there will be an additional cost. Otherwise all other sheet metal is to be supplied by and installed by others. Additional Information Roof Drains and Expansion Cup Links: For. the Thermoplastic Polyolefin (TPO) roofing system' all roof drains and expansion cup links will be removed and disposed of. New cast iron roof drains with overflows will be installed with new expansion cup links. The cast iron drains are required for the TPO system because the roofing system requires clamping drains. For the foam roofing system the existing roof drains will be reused and the expansion cup -links will be replaced. This is included into the contract amounts. Damaged Plywood & Fascia: Damaged plywood, board or other substrate will need to be replaced. Since we cannot see if there is any or how much damaged wood there is this is not included into the contract amount. RDW can remove and replace any damaged plywood sheeting at $ 65.00 per sheet. Other substrates will be removed and replaced at a time and material based cost. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 Additional Information (continued) Exclusions: Permit not included, permit can be provided at cost. Removal and reinstallation of all roof top equipment, AC units, solar panels, lines and etcetera are excluded. Any items not noted though the visible inspection of the roof systems are excluded. Any item or items that are not specified in the above information -are not included. Warranty Information Thermoplastic Polyolefin (TPO) Warranty: RDW will warranty the Thermoplastic Polyolefin (TPO) roofing system for a period of five years (5). If the roofing systems are annually maintained in a Roof Maintenance Program by R D Winkle Company during the applicable warranty period the warranty will be extended to ten years (10). Please see WORKMANSHIP, MATERIALS AND SYSTEMS WARRANTY for more information. Contract Amounts Thermoplastic Polyolefin (TPO) Roofing System: $ 29,772.00 Annual Roof Maintenance Program: $ 250.00* * An Additional Contract will be Provided for the Maintenance Program Accepted By: Respectfully Submitted, �C Ryan A. Winkle Supervisor/Estimator Date: P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 IMES Evaluation Report ESR -1463 (� ICC-ES/UL Dual Report Reissued August 1, 2012 This report is subject to renewal October 1, 2014. Click on the logo to access UL Certification www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-M6nomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC INCORPORATED PO BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717) 245-7000 www.carlisle-syntec.com EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING MEMBRANES ADDITIONAL LISTEES: VERSICO INCORPORATED POST OFFICE BOX 1289 CARLISLE, PA 17013 MULE -HIDE PRODUCTS COMPANY, INC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 WEATHERBOND P.O. BOX 251 PLAINFIELD, PENNSYLVANIA 17081 KELLY COMPANY/2001 INC. 325 THOMASTON AVENUE WATERBURY, CONNECTICUT 06702 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2006 International Building Code (IBC) ■ 2006 International Residential Code® (IRC) ■ Other Codes (see Section 8.0) Properties evaluated: ■ Weather resistance ■ Roof covering fire classification ■ Wind uplift resistance ■ Impact resistance 2.0 USES 'Carlisle ethylene propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single -ply roofing membranes are used as roof coverings in adhered and mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single -ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule -Hide Products Company, Inc., WeatherBond, Versico Incorporated and Kelly Company/2001 Inc.,,the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced EPDM membrane available in 45-, 60- and 90 -mil (1.14, 1.52, and 2.29 mm) thicknesses. 3.2.2 Sure -Seal FR: Sure -Seal FR is a black, nonreinforced EPDM membrane with fire retardants, available in 45-, 60- and 90 -mil (1.14, 1.52, and 2.29 mm) thicknesses. 3.2.3 Sure -White: Sure -White is a white, nonreinforced EPDM membrane available in a 60- and 90 -mil (1.52 and 2.29 mm) thickness. 3.2.4 Sure -Tough: Sure -Tough is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies. It is available in 45- to 75 -mil (1.14 to 1.90 mm) thicknesses. 3.2.5 Sure -Tough FR: Sure -Tough FR is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies with fire retardants. It is available in 45 to 60 -mil (1.14 to 1.52 mm) thickness. 3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM bonded to a 5.5 -ounce -per -square -yard (0.18 kg /M2) polyester fleece. 3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white EPDM bonded to a 5.5 -ounce -per- square -yard (0.18 kg /M2) polyester fleece. /CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as to arty finding or other matter in this report, or as to any product covered by the report. �aoo Copyright 0 2012 Page 1 of 10 ESR�1463 1 Most Widely Accepted and Trusted Page 2 of 10 3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece. 3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a 60 -mil (1.52 mm) non -reinforced EPDM bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece. 3.3 PVC Membranes: 3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and Sure -Flex Elvaloy are 50-, 60-, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a polyester reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray or custom colors. 3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure - Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60-, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a fiberglass reinforcement encapsulated between two plies of PVC. The membrane .is available in white, gray or custom.colors. 3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex Elvaloy FRS FleeceBACK: Sure -Flex 'FRS FleeceBACK and Sure -Rex Elvaloy FRS FleeceBACK are the Sure -Flex FRS membrane and the Sure -Flex Elvaloy FRS membrane, described in Section 3.3.2 with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m�) polyester fleece backing. 3.4 TPO Membranes: 3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or 1.52 mm) membrane consisting of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available in white, gray, tan or custom colors. 3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. It is manufactured in 45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is available in white, gray, tan or custom colors. 3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of Sure -Weld HS membrane with adhesive. 3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same formulation as the Sure -Weld membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is the same formulation as the Sure -Weld HS membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or 1.52 mm) thick with a laminated 5.5 -ounce -per -square - yard (0.18 kg/m�) polyester fleece backing. 3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil (1.14 mm) Sure -Weld HS membrane with a laminated 10 -ounce -per -square -yard (0.34 kg/m2) polyester fleece backing. 3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is the 60 -mil (1.52 mm) Sure -Weld HS membrane with a laminated 10 -ounce -per -square -yard (0.34 kg /M2) polyester fleece backing. 3.4.9 Spectro-Weld: Spectro-Weld its the Sure -Weld membrane, described in Section 3.4.1, and Sure -Weld EXTRA membrane, described in Section 3.4.4, formulated with a brighter white color. It is manufactured in 45-, 60-, 72- or 80 -mil (1.14-, 1.52-, 1.83- or 2.03 -mm) thicknesses. 3.4.10 Spectro-Weld FleeceBACK: Spectro-Weld FleeceBACK is the Spectro-Weld membrane with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece backing. 3.5 Insulation: See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must have a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84. - 3.6 Barrier Board: Barrier board, where used, must be either minimum '/4 -inch -thick (6.4 ml G -P Gypsum Corporation "DensDeck, minimum /4 -inch -thick (6.4 mm) Owens Corning "Strataguard", minimum '/4 -inch -thick (6.4 mm) USG "Securock," or minimum 1/2 -inch -thick (12.7 mm) gypsum board. Barrier board must be UL- listed for roofing applications or UL -classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle "FR Base Sheet 1S or 2S," Elk "VersaShield Underlayment," Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or FR 50." 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No: 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.9 Fasteners: Fasteners, used to mechanically attach insulation and membranes to the roof deck, must be corrosion -resistant, and must be Carlisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 for spacing of fasteners. 3.9.1 Sure -Seal HP Fastener: This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy - coated steel screw used in combination with - Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/4 inch (19.1 mm.) 3.9.3 Sure -Seal HD 14-10 Fastener: This is a heavy- duty, epoxy -coated steel screw used in combination' with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). . 3.9.4 Sure -Seal HP Polymer Seam Plate: This is a 2 -inch -diameter (50 mm) polymer plate designed to be used with Sure -Seal HP and Sure -Seal HD 14-10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.5 Sure-Tite Fastener and ST Fastening Bar: This is a heavy-duty, epoxy -coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by -10 - foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume-coated steel with prepunched holes 6 inches (150 mm) on center. ESR -1463 I Most Widely Accepted and Trusted Page 3 of 10 3.9.6 HP -X Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.7 Piranha Fastening Plate: This is a 23/8 -inch - diameter galvalume-coated steel plate designed to be used with HP -X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.8 HP-XTRA Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.9 Piranha XTRA Fastening Plate:' This is a 23/8 -inch -diameter galvalume-coated steel plate designed to be used with HP-XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.10 OMG Inc. RhinoBond Plate: The RhinoBond Plate is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP -X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Adhesives: 3.10.1 Sure -Seal 90-8-30A: Sure -Seal 90-8-30A is a high- strength, solvent -based contact adhesive used to adhere EPDM membranes to the insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base 120 is a high-strength, water-based contact adhesive used to adhere EPDM and TPO membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 M2 A-). The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex PVC and Sure -Rex Low VOC PVC Bonding Adhesives are high-strength, solvent -based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m IL). The adhesives are supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere membranes to an insulation or substrate. It has a coverage rate of approximately. 60 square feet per gallon (1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, Flexible FAST and FAST Bag -in -a -Box Adhesives are two -component polyurethane adhesives used to adhere FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 M2 /L). The adhesives are supplied in 15 -gallon (56.7 L) and 50 -gallon (189 L) drums, cartridge tubes or cylinders, and have a shelf life of one year. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in IBC Section 1504.7, based on testing in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published installation instructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All materials must be protected against contact with incompatible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which the single -ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations of the roof covering must be flashed and made weather tight in accordance with the requirements of the membrane manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, PVC, and TPO single -ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E 108 and UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: ■ New uninsulated systems installed only over existing uninsulated assemblies. ■ New insulated systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction:. The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. ESR -1463 1 Most Widely Accepted and Trusted Page 4 of 10 Metal edge securement for roofing systems must be designed in accordance with ANSI/SPRI ES -1, complying' with IBC Section 1504.5. The edge securement for mechanically attached membranes was tested in accordance with ANSI/SPRI ES -1 Test RE -1, using Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003 aluminum] and Carlisle SecurEdge 3000 [0.040 -inch (1.02 mm) 3003 aluminum] fascia systems. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer's published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturer's installation instructions and this report. 5.2 The adhered and mechanically fastened single -ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R314.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and comer zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Table 4. 5.6 The allowable wind uplift pressures listed in Table 4 are for the roof covering system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. 5.8 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, • Mississippi, under a quality control program with inspections by UL LLC (AA -668). 5.9 For buildings under the IBC, above -deck thermal insulation board must comply with the applicable standards listed in Table 1508.2 of the IBC. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC -ES Acceptance Criteria for Membrane Roof Covering Systems (AC75), dated April 2007, (corrected December 2008). 7.0 IDENTIFICATION Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec Incorporated) or the name of the additional listee, the manufacturer's address or plant code, the ICC -ES evaluation .report number (ESR -1463), and the name or label of the inspection agency (UL LLC). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: ■ BOCe National Building Code/1999 (BNBC) v 1999 Standard Building Code® (SBC) ■ 1997 Uniform Building Code TM (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: 3.8 Flashing: Flashing must be provided in accordance with SBC Section 1503.2, BNBC Section 1508.1 and UBC Section 1509, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in BNBC Section 1505.4.2, and SBC Section 1504.6, based on testing in accordance with FM 4470. 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 8.0 of this report, subject to the following conditions: See Sections 5.1 through 5.8, except revise Section 5.3 to read as follows: 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with BNBC Section 2603.4.1.5, SBC Section 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as applicable. ESR -1463 -1 Most Widely Accepted and Trusted Page 5 of 10 wpSslFj�o low�;SSIFjFO ��C.?;-T,;:ji19•�L:£a",i}`"c.�5'� e�1�i?yii�,�;i.":•f1.41YCLi Y2+7'�u�6`e5.lt�. oci. }7 . -S-a e}t 1c i5 Ufit iun :? pS3IFj�o h:�itr7il;??•1r .la?'t'.�!.ug;.toi.� :�;r?s#ts'tF _ ii ra;>v�ez�r�+x1:F'sr�:Frli�wbt��e.. FIGURE 1—INSPECTION AGENCY LABEL e ESR -1463 I Most Widely Accepted and Trusted Page 6 of 10 TABLE 1—PRODUCT NAMES CARLISLE PRODUCT MULE -HIDE PRODUCT WEATHERBOND PRODUCT VERSICO PRODUCT KELLY CO./ NAME NAME NAME NAME 2001 INC. PRODUCT NAME Sure -Seal Mule -Hide Standard WeatherBond RBR EPDM Versigard EPDM Membrane Sure -Seal FR Mule -Hide FR EPDM WeatherBond RBR FR EPDM Versigard Nonreinforced C-EPDM-C Membrane EPDM Sure -Tough Reinforced Mule -Hide Standard WeatherBond RBR Standard Versigard Reinforced C-EPDM-CR Reinforced EPDM Reinforced EPDM Membrane Sure -Tough FR Mule -Hide FR Reinforced Versigard FR Reinforced C-EPDM-CR Type 1 Reinforced EPDM Sure -White Mule=Hide White -on- WeatherBond RBR White EPDM Versigard Nonreinforced EPDM RF - White Black EPDM Membrane EPDM -White Sure -Weld Mule -Hide TPO-c WeatherBond PRO TPO Versiweld Reinforced TPO /White Membrane TPO Sure -Weld HS Mule -Hide TPO-c (FR) Versiweld ES SAT-TPO Mule -Hide SA-TPO WeatherBond PRO PAS TPO Versiweld OA TPO Sure -Weld EXTRA Mule -Hide TPO-c Extra WeatherBond PRO TPO Versiweld PLUS Membrane Sure -Weld HS EXTRA Mule -Hide TPO-c Extra Versiweld ES PLUS (FR) Sure -Weld FleeceBACK Mule -Hide TPO-c Fleece Versiweld VersiFleece Back Sure -Flex Mule -Hide PVC WeatherBond PRO PVC VersiFlex Reinforced. Membrane PVC Membrane Sure -Flex -FRS Mule -Hide FRS PVC VersiRex FRS Membrane Reinforced PVC Membrane Sure -Seal 90-8-30A Mule -Hide Bonding WeatherBond RBR LC -60 Bonding G200SA Yellow 2001 Inc. Bonding Bonding Adhesive Adhesive . Adhesive Substrate Adhesive Adhesive Sure -Seal Aqua Base 120 Mule -Hide Water -Based Aqua Base 120 Bonding Adhesive Aqua Base 120 Bonding Bonding Adhesive Bonding Adhesive. Adhesive Sure -Weld Bonding Mule -Hide TPO-c WeatherBond PRO TPO Bonding Versiweld Bonding Adhesive Bonding Adhesive Adhesive Adhesive Sure -Weld Low VOC Mule -Hide TPO-c Low Versiweld LOW VOC Bonding Adhesive VOC Bonding Adhesive Bonding Adhesive Sure -Flex PVC Bonding Mule -Hide PVC Bonding WeatherBond PRO PVC Bonding VersiFlex PVC Bonding Adhesive Adhesive Adhesive Adhesive Sure -Flex Low VOC PVC Mule -Hide Low VOC VersiFlex Low VOC PVC Bonding Adhesive PVC Bonding Adhesive Bonding Adhesive FAST 100 Adhesive Mule -Hide SP -100 FAST 100 Adhesive Adhesive FAST 100 LV Adhesive Mule -Hide SP -100 -LT FAST 100 LV Adhesive Adhesive ESR -1463 I Most Widely Accepted and Trusted Page 7 of 10 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2'5 SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE/MAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Sure -Weld, Spectro-Weld -'/4:12 Any of the following insulations, Sure -Seal, Sure -Tough, Sure -White, Sure - 1 -inch min. to 6 -inch max. thickness: Carlisle "SecurShield Seal FleeceBACK, Sure -Weld HS, SAT-TPO, 1 A Noncombustible Polyiso", "Polyiso HP -H", Hunter Sure -Weld FleeceBACK, Spectro-Weld FleeceBACK /2:12 Panels "H -Shield" or "H -Shield -CG" Sure -White FleeceBACK, Sure -Flex, Sure - Flex FRS /4:12 1/2 -inch -thick fiberboard 4, 1/2 Sure White FleeceBACK-3/4:12 inch -thick fiberboard or barrier board (see Section 3.6) over 5 Sure -Seal; Sure -Tough - 1:12 2 A Noncombustible — inch max Insulfoam EPS3, 1/2- Sure -White, Sure -Seal FleeceBACK, Sure - inch -thick fiberboard or barrier Weld, Spectro-Weld, Sure -Weld HS, SAT - board (see Section 3.6) over TPO, Sure -Weld FleeceBACK, Spectro-Weld System No. 1 insulations FleeceBACK, Sure -Rex, Sure -Flex FRS - 1 /2:12 Sure -White FleeceBACK-3/4:12 Noncombustible or Sure -White, Sure -Seal FleeceBACK - 11/2:12 Combustible - min. Sure -Tough, Sure -Weld, Spectro-Weld, Sure - 3 A 15/32 -inch -thick Barrier board — Weld FleeceBACK, Spectro-Weld plywood or min. (see Section 3.6) FleeceBACK - 3:12 '/16 -inch -thick OSB. Sure -Weld HS, SAT-TPO - 4:12 Sure -Seal FR, Sure -Flex, Sure -Flex FRS — unlimited slope Any of the following insulations, Sure-Weld_Spectro-Weld - 1/4:12 Combustible - min. Barrier board 1 -inch min. Sure -Seal, Sure -Tough, Sure -White, Sure - 15/32 -inch -thick (see Section 3.6) or to 6 -inch max. thickness: "SecurShield Seal FleeceBACK, Sure -Weld HS, SAT-TPO, 4 A plywood or min, Slip sheet: 2 layers Carlisle Polyiso", Sure -Weld FleeceBACK, Spectro-Weld 7/16 -inch -thick OSB. (see Section 3.7) Polyiso HP -H", "H FleeceBACK - /2:12 Hunter Panels -Shield" or Sure -White FleeceBACK, Sure -Flex, Sure - "H -Shield -CG" Flex FRS -3/4:12 Combustible - min. 15/32 Any of the following insulations, Sure -Weld, Spectro-Weld, Sure -Weld HS, 5 C -inch -thick _ 2 -inch min. to 6 -inch max. "Polyiso SAT -TPC, Sure -Flex, Sure -Flex FRS — plywood or min. '/16 thickness: Carlisle HP- "H unlimited slope -inch -thick OSB. H" or Hunter Panels -Shield" Single layer of minimum 3.0" or double layer of minimum 1.5" 6 A Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes - 1/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1.9" 7 B Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes - 1/2:12 Hunter Panels "H -Shield -CG" For SI: 1 inch = 25.4 mm 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2See Section 3.10 for adhesive application rate. 3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. 1/2:12. 5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR -1463 1 Most Widely Accepted and Trusted Page 8 of 10 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE/MAX. ROOF NO. CLASS OR SLIP SHEET SLOPE Any of the following insulations, 1 inch min. to "SecurShield Sure -Tough, Sure -Weld, Spectro-Weld, Sure -Flex, Sure - 1 A Noncombustible — 6 -inch max. thickness: Carlisle "H Flex FRS - /2:12 Polyiso" or "Polyiso HP -H", Hunter Panels "H Sure -Weld HS - 11/212 Shield" or -Shield -CG" Sure -Tough FR - 2:12 '/-inch-thick fiberboard 3,'/z_inch-thick Sure -Tough, Sure -Weld HS, fiberboard° or barrier board (see Section 3.6) Sure -Flex, Sure -Flex FRS - 1:12 2 A Noncombustible — over 5 -inch max Insulfoam EPS2, '/z -inch -thick Sure -Weld, Spectro-Weld - fiberboard or barrier board (see Section 3.6) 1'/2:12 over System No. 1 insulations Sure -Tough FR - 31/2:12 Sure -Weld, Spectro-Weld, Sure - 3 A Noncombustible — To 5 -inch max: Insulfoam SP Weld HS, Sure -Flex, Sure -Flex FRS -'/2:12 Noncombustible or 4 Sure -Tough, Sure -Weld, Combustible - min. Barrier board Spectro-Weld - 3:12 4 A 15/& -inch -thick (see Section 3.6) — Sure -Tough FR - 31/2:12 plywood or min. Sure -Weld HS, Sure -Rex, Sure - _ 6 -inch -thick OSB. Flex FRS - unlimited Combustible - min. Barrier board Any of the following insulations, 1 -inch min. Sure -Tough, Sure -Weld, 16/ (see Section 3.6) to 6 -inch max, thickness: Carlisle Spectro-Weld, Sure -Flex, Sure - 5 A �-inch-thick plywood or min. or Slip sheet: 2 "SecurShield Polyiso" or "Polyiso HP -H", , Flex FRS - /2:12 7/16 -inch -thick OSB. layers, (see Section Hunter Panels Sure -Weld HS, 11 /2:12 3.7) "H -Shield" or "H -Shield -CG" Sure -Tough FR - 2:12 Combustible - min.Sure-Tough - 1:12 15/3 -inch -thick Slip sheet, 2 layers Sure -Tough FR, Sure Weld, 6 A plywood or min. (see Section 3.7) — Spectro-Weld, Sure -Weld HS, '/,6 -inch -thick OSB. Sure -Flex, Sure -Flex FRS - 1 /2:12 Combustible - min. Sure -Tough, Sure -Tough FR, 7 B 15/32 -inch -thick Slip sheet, 1 layer _ Sure -Weld, Spectro-Weld, plywood or min. (see Section 3.7) Sure -Weld HS, Sure -Flex, Sure - 7/,6 -inch -thick OSB. Flex FRS - 11/2:12 Combustible - min. Any of the following insulations, 2 -inch min. 15/32 -inch -thick to 6 -inch max. thickness: Carlisle Sure -Weld, Spectro-Weld, 8 C. plywood or min. — "SecurShield Polyiso" or "Polyiso Sure -Weld HS, Sure -Flex, Sure- ure- 7/,6-inch-thick /, 6 -inch thick OSB. HP -H", Hunter Panels "H -Shield" or H -Shield Flex FRS - unlimited CG" Single layer of minimum 3 -inch or double 9 A Combustible — layer of minimum 1.5 -inch Carlisle EPDM, PVC, and TPO . "SecurShield Polyiso" or Membranes - 1/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1.9 -inch Carlisle 10 B Combustible — "SecurShield Polyiso" or Hunter Panels "H- EPDM, PVC, and TPO Shield -CG" or single layer of an inverted G3 Membranes -'/2:12 cap sheet. For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. - 2UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope -1:12) or below min. '/-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/2:12. 4When these systems are used for reroofing or recovering, installation must be in accordance with Sections A.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR -1463 1 Most Widely Accepted and Trusted Page 9 of 10 " TABLE 4—WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°'' SYSTEM MAXIMUM DECKS INSULATION 5 MEMBRANE MEMBRANE MAXIMUM MAXIMUM NO. ALLOWABLE FASTENING FASTENER FASTENER WIND UPLIFT SPACING ROW (psf) (inches) SPACINGS Foam plastic insulation ?• 1 45 Noncombustible 1/zinch-thi k fiberboard or Sure -Tough HP -X Fastener & Metal Fastening Bar 12 6 ft 6 inches barrier (ward (See Sect. 3.6) 2 75 Noncombustible Same as System No. 1 Sure -Tough HP -X Fastener & Metal Fastening Bar 6 6 ft 6 inches 3 52 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & Polymer Seam Plate 6 9 ft 6 inches 4 45 Noncombustible Same as System No. 1 Sure -Tough Sure-Tite Fastener & 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 12 9 It 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure -Weld, HP -X or HP -Xtra 7 45 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 7 ft 6 inches Spectro-Weld or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure -Weld, Sure -Weld EXTRA, or HP -Xtra Fasteners with 12 9 It 6 inches Spectro-Weld Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 9 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha or Piranha Xtra 6 9 ft 6 inches Spectro-Weld Plates Sure -Weld, HP -X or HP -Xtra 10 67 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 7 ft 6 inches Spectro-Weld or Piranha Xtra Plates Sure Weld, HP -X or HP -Xtra 11 30 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 11 It 6 inches Spectro-Weld or Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 12 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 11 It 6 inches Spectro-Weld or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 6 6 ft 4 inches Piranha Plates 14 83 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 6 2 ft 11 inches Piranha Plates HP -X or HP -Xtra 15 30 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 18 6 It 4 inches or Piranha Xtra Plates HP -X or HP -Xtra 16 45 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 12 2 It 11 inches Piranha Plates 18 45 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with 1 per 5.3 ftz N/A OMG RhinoBond Plates 19 60 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with 1 per 4 to N/A OMG RhinoBond Plates For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa. 'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso","Polyiso HP -H" Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG". 2All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 3Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f,) of 2500 psi. See Section 5.6 of this report. °For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. 5UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope -1:12) or below min. 1/zinch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 6Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to V212. ESR -1463 I Most Widely Accepted and Tnisted Page 10 of 10 Table 4 footnotes cont'd When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. 9 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened- roof assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 pit (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3.000 is 200 pif (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly. TABLE 5—WIND RESISTANCE — ADHERED ASSEINBLIES5 SYSTEM ALLOWABLE DECK INSULATION / MIN. THICKNESS'a INSULATION MEMBRANE NO. WIND UPLIFT FASTENING TYPE (FIELD) (psf) RATE 1 45 Combustible or '/2 inch fiberboard, 15/32 inch OSB, or barrier board (See 1er 2 fl? P EPDM, PVC and TPO Noncombustible Section 3.6) Membranes 2 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter "H "H 2 EPDM, PVC and TPO 45 Noncombustible Panels -Shield" or -Shield -CG"/ 1.4 inch '/cinch 1 per 3.2 ft Membranes withSecurock coverboard (optional) 3 45 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter Panels "H -Shield" or "H -Shield -CG" / 2.0 inch 1 4 ftz EPDM PVC and TPO Noncombustible 5/,rinch per Membranes with Securock ooverboard (optional) 4 68 Combustible or Carlisle "Polyiso HP -H" or "SecurShleld Polyiso"; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels "H -Shield" or "H -Shield -CG" / 1.0 inch 5 75 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter Panels "H -Shield" "H / 2.0 inch 1 1.6 ft2 EPDM, PVC and TPO Noncombustible or -Shield -CG" with '/Z -inch Securock coverboard (optional) per Membranes 6 120 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter "H `H 1 Per 1 ft 2 TPO Membranes; EPDM membranes (with Noncombustible Panels -Shield" or -Shield -CG" / 2.0 inch noncombustible deck only) Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter 7 128 Noncombustible Panels "H -Shield" or "H -Shield -CG" / 2.0 inch 1 per 1 If EPDM and TPO Membranes with'/2-inch Securock coverboard (optional) Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter 8 135 Noncombustible Panels "H -Shield" or "H -Shield -CG" / 2.0 inch 1 per 1 ft2 FleeceBACK Membranes with'/2-inch Securock coverboard (optional) 9 143 Combustible or Noncombustible '/2 inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness, in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. zSteel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)). Concrete must have a minimum compressive strength (Fc) of 2500.psi. See Section 5.6 of this report. 3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slopel:12) or below min. '/z -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. °Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/2:12. 'When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time -of permit application. For reroofing or recovering, installation must be in accordance with IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. . Find rated products - Cool Roof Rating Council 1 SEARCH RESULTS Selected filters Manufacturer: Carlisle Construction Materials Incorporated 4/16/14, 12:49 PM PRINT EXPORT ALL PRODUCTS CRRC PROD. ID MANUFACTURER. BRAND PRODUCT TYPE COLOR SOLAR REFLECTANCE THERMAL EMITTANCE SRI. MORE MODEL INFO initial 3 year initial 3 year initial 3 year 0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 99 85 Incorporated: Sure -Weld Ply Thermoplastic TPO White and Thermoset Roofing COOL ROOF RATING COUNCIL 1610 Harrison Street Tel (866) 465-2523 or Fax (510) 482-4421 Oakland, CA 94612 (510) 485-7175 Email: infoacoolroofs.or9 e:///Users/RAW/Desktop/Material%201nfo%20&%2OSpec./TPO%201nfo.%20&%2OSpec./TPO%2OCool%2oRoof%201nfo.webarchive Page 1 of 1 INSTALLATION CERTIFICATE: Residential Reroof CF -6R -ENV -01 Site Address: 77000 Avenida Fernando, La Quints, CA. 92253 Enforcement Agency:Permit Number: If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures_ with check boxes are required to be checked to ensure the mandatory measures have been met. CEILING INSULATION Rigid:' Brand Name: Batt or Blanket Type: Brand Name: Loose Fill Type: Thermal Resistance (R -Value): Spray Foam Type: Brand Name: Installed Actual Thickness (inches): Contractor's min installed weight/ftz Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value): ❑ §150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. ❑ §118(a): Insulation installed meets Standards for Insulating Material. ❑ § 150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16. lb ROOFING PRODUCTS (COOL ROOFS) §151(1)12 ❑ Check this box if the newly installed roof is exempted from the roofing product "Cool Roof' requirements as indicated on the CF -1R -Alt- ' Reroof form for this project. Otherwise fill in the table below. Responsi Person's Si nature: Roof Slope Product Weight CSLB License: Aged Solar Thermal 688062 CRRC Product ID Number' < 2:12 > 2:12 < 5lb/fe > 5lb/ft2 Product Type2 Reflectance 3,4 Emittance 0628-0002 .❑ 1 ® ❑ 11. TPO ❑4 .70 .90 ❑ 1 ❑ ❑ ❑ ❑4 1. CRRC-1 label information is available is on the package of the roofing product being installed and attach the CRRC label to this form. 2. Indicate the type of product is being used for the roof top, i.e. single -ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory theft use the Initial Reflectance value frost the sante directory and use the equation (0.2+0.7(pi�i1ia1 — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage ecommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating TO Cement -Based Roof Coating ❑ Other DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. • 1 reviewed a copy of the Certificate of Compliance (CF -1 R) form approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed on the CF -1 R that apply to the installation have been met. • I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) R D Winkle co. _ Responsible Person's Name: Responsi Person's Si nature: Ryan A. Winkle CSLB License: Date Signed: Po 'o ith Company (Title): 688062 14-16-2014 ervisor 2008 Residential Compliance Forms . August 2009 Bin.# Qty'of La Qulnta Building 8t Safety Division P.O. Box 11504,78-495 Caffe Tampico 1A.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 77000 Avenida Fernando, La Quinta, CA, 92253 Owner's Name:. Mr. Doug Long A. P. Number: 658240013 Address: 77000 Avenida Fernando Legal Description: City, ST, Zip: La Quints, CA. 92253 Contractor: R D Winkle co Address: P.O. Box 476 Telephone: ,; Project Description: New 60mil Thermoplastic Polyolefin (TPO) City, ST, Zip: Thousand Palms, CA. 92276 roofing system with 1" EPS insulation board. Telephone: 760-322-5144 - Y " -f'� cl'-%�'�" "� �, � 'r= The existing.BUR roof is to be recovered. State Lic. 4: ' 688062 City Lie #: The new roofing system will be mechanically fastene Arch., Engr., Designer. to 1-90 specifications. Address: City., ST, Zip: ` Telephone: �R a "'` " State Lie. #:f .�` ,- �i.�'r-N.z� .; � Name of Contact Person: Ryan A. Winkle Construction Type:. Roofing Occupancy: Projecttype (circle one : New Add'n. Alter Repair Demo Sq. Ft_: 3,500 4 Stories: 1 #Unit: Telephone # of Contact Person: Estimated Value of project: $ 29,772.00 APPLICANT: DO NOT WRITE BELOW THIS UNE t! Submittal Req'd "Reed TRACXMG PERMIT FEES Plan Sets Pian Check submitted. Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit, . Truss Cates. Called Contact Person Plan Check Balance. Title 24 Calc§. Plans picked up Construction ' Flood plain plan Plans resubmitted'. . Mechanical Grading plan 2'' Review, ready for correctionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review', ready for correctionsrasue Developer Impact Fee Planning Approval Called Contact Person A.IP.P. Pub. Wks. Appr " Date of permit issue School Fees Total Permit Fees