14-0451 (RR)4 P.O. BOX 1504 ^' VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 4/16/14
Application Number: 14-00000451 Owner:
Property Address: 77000 AVENIDA FERNANDO DOUG LONG
APN: 658-240-013- - - 77000 AVENIDA FERNANDO
Application description: RE -ROOF LA QUINTA, CA 92253 D n
Property Zoning: LOW DENSITY RESIDENTIAL ( (�
Application valuation: 29772 p cy
Contractor: APR t 5 2@114
A ipanvxlla�
Architect or Engineer: WINKLE COMPANY, R.D.
P.O. BOX 476 C F r OF LA QUINTA
CSC/ THOUSAND PALMS, CA 92276 �rtif4.:�� i)p1.
(760)322-5144
Lic. No.: 688062
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: C39 C46 LicenseNV 688062
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of erjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State .
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) .1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law3.
( ) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations: -
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0000182-2014
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of th
✓1Je Labor Co , I shall forthwith comply wi h those provisions.
Date l t+ / V ' Applicant:
WARNING: FAILURE TOS WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property f inspection purposes.
Date: 0 `� Signature (Applicant.or Agent):
Application Number
Permit . . .
Additional desc . .
Permit Fee . . . .
Issue Date . . . .
Expiration Date . .
. . . . 14-00000451
RE -ROOF
71.50 Plan Check Fee . . .00
Valuation . . . . 0
10/13/14
Qty Unit Charge Per Extension
1.00 48.6200 LS MISC RE -ROOF, 1ST 2000 SF 48.62
2.00 11.4400 EA MISC RE -ROOF, ADDL 1000 SF 22.88
----------------------------------------------------------------------------
Special Notes and Comments
RE -ROOF NEW 60 MIL THERMOPLASTIC (TPO)
ROOFING .SYSTEM WITH 1" EPS INSILATION
THE EXISTING ROOF IS TO BERECOVERED. THE
NEW ROOF SYSTEM WILL BE MECHANICALLY
FASTENED TO 1-90 SPECS. 2013 CBC.
----------------------------------------------------------------------------
Other Fees . . . . . BLDG STDS ADMIN (SB1473) 1.00
PLAN CHECK, RE -ROOF 97.24
Fee summary
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
LQPERMIT
Charged Paid Credited Due
71.50 .00 .00 71.50
.00 .00 .00 .00
98.24 .00 .00 98.24
169.74 .00 .00 169.74
The Long Residence
77000 Avenida Fernando
La Quinta, CA. 92253
Attn: Mr. Doug Long
Wednesday, April 2, 2014
Re: Thermoplastic Polyolefin (TPO) Roofing System with V EPS Insulation
This proposal is in regard to the above referenced project. We are proposing to supply
and install a new Thermoplastic Polyolefin (TPO) roofing. system with 1" EPS insulation.
Furnishings and installations will be as explained below;
Surface Preparation's
Demolition & Clean Up: RDW will remove the gravel surface from the low -slope roofing
system. This will give a cleaner surface for the preparations of the new roofing system and will
ensure the new materials will not be punctured. All debris on the ground will be swept up and
the grounds will be rolled with a magnet to pick up any fasteners and or metal scraps that had
fallen during the demolition. RDW will dispose of all roofing waste.
Low -Slope Roofing Systems
Thermoplastic Polyolefin (TPO) Roofing System
Board Insulation: RDW will supply and installed a single layer of I" rigid EPS board
insulation. The board insulation will overlay the existing built-up roof. By overlaying the
existing built-up roof the waste.will be minimized and the new roofing system will maintain a
class "A "fire rating. The EPS will provide a smooth surface for the new roofing system and will
give additional insulation of approximately R-6 aged value RDW will. mechanically fasten the
insulation to the substrate using 3" plates and 2" fasteners. The fasteners will be installed in an
I-90 pattern giving a 90mph wind rating. Additional insulation will be added to standing water
areas. This will help reduce standing water, not eliminate it.
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
Thermoplastic Polyolefin (TPO) Roofing System (continued)
Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing system.
We will be installing a 60mil-reinforced membrane that will be 8' or 10' by 100' roll. This
allows us to have less field seams and end lap seams. than your typical built-up roofs. This is a
sure weld membrane meaning that all seams are heat welded together, compared to either hot
tar in a built up roof or an open flame used in torch on roofs. The field will be seamed with a
robotic heat welder giving a continuous and consistent weld Details, such 'as flashings and
corners will be welded by hand. Welds will then be checked with a probe. The product is much
safer, cleaner, and does not produce any unpleasant odor when being installed Other positives
to this roofing system are that the TPO membrane is highly reflective and helps reduce energy
consumption cost, it will provide a long term resistance to the punishing ultraviolet rays we
receive here in the western states. This system meets California Title 24 specifications. The
TPO roofing system will be installed to the manufactures specifications. This roofing system
meets the specifications for a Manufacture 20 year No Dollar Limit (NDL) Warranty.
Sheet metal: RDW will supply and install the following TPO coated sheet metal; edge metal,
T -Top vents and scuppers. If other sheet metal is desired to be. installed by RDW there will be an
additional cost. Otherwise all other sheet metal is to be supplied by and installed by others.
Additional Information
Roof Drains and Expansion Cup Links: For. the Thermoplastic Polyolefin (TPO) roofing
system' all roof drains and expansion cup links will be removed and disposed of. New cast iron
roof drains with overflows will be installed with new expansion cup links. The cast iron drains
are required for the TPO system because the roofing system requires clamping drains. For the
foam roofing system the existing roof drains will be reused and the expansion cup -links will be
replaced. This is included into the contract amounts.
Damaged Plywood & Fascia: Damaged plywood, board or other substrate will need to be
replaced. Since we cannot see if there is any or how much damaged wood there is this is not
included into the contract amount. RDW can remove and replace any damaged plywood sheeting
at $ 65.00 per sheet. Other substrates will be removed and replaced at a time and material based
cost.
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
Additional Information (continued)
Exclusions: Permit not included, permit can be provided at cost. Removal and reinstallation of
all roof top equipment, AC units, solar panels, lines and etcetera are excluded. Any items not
noted though the visible inspection of the roof systems are excluded. Any item or items that are
not specified in the above information -are not included.
Warranty Information
Thermoplastic Polyolefin (TPO) Warranty: RDW will warranty the Thermoplastic
Polyolefin (TPO) roofing system for a period of five years (5). If the roofing systems are
annually maintained in a Roof Maintenance Program by R D Winkle Company during the
applicable warranty period the warranty will be extended to ten years (10). Please see
WORKMANSHIP, MATERIALS AND SYSTEMS WARRANTY for more information.
Contract Amounts
Thermoplastic Polyolefin (TPO) Roofing System: $ 29,772.00
Annual Roof Maintenance Program: $ 250.00*
* An Additional Contract will be Provided for the Maintenance Program
Accepted By:
Respectfully Submitted,
�C
Ryan A. Winkle
Supervisor/Estimator
Date:
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
IMES Evaluation Report ESR -1463
(� ICC-ES/UL
Dual Report
Reissued August 1, 2012
This report is subject to renewal October 1, 2014.
Click on the logo to access UL Certification
www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 53 23—Ethylene-Propylene-Diene-M6nomer
Roofing
Section: 07 54 19—Polyvinyl-Chloride Roofing
Section: 07 54 23—Thermoplastic-Polyolefin Roofing
REPORT HOLDER:
CARLISLE SYNTEC INCORPORATED
PO BOX 7000
CARLISLE, PENNSYLVANIA 17013
(717) 245-7000
www.carlisle-syntec.com
EVALUATION SUBJECT:
CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING
MEMBRANES
ADDITIONAL LISTEES:
VERSICO INCORPORATED
POST OFFICE BOX 1289
CARLISLE, PA 17013
MULE -HIDE PRODUCTS COMPANY, INC.
1195 PRINCE HALL DRIVE
BELOIT, WISCONSIN 53511
WEATHERBOND
P.O. BOX 251
PLAINFIELD, PENNSYLVANIA 17081
KELLY COMPANY/2001 INC.
325 THOMASTON AVENUE
WATERBURY, CONNECTICUT 06702
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2006 International Building Code (IBC)
■ 2006 International Residential Code® (IRC)
■ Other Codes (see Section 8.0)
Properties evaluated:
■ Weather resistance
■ Roof covering fire classification
■ Wind uplift resistance
■ Impact resistance
2.0 USES
'Carlisle ethylene propylene diene monomer (EPDM),
polyvinyl chloride (PVC) and thermoplastic polyolefin
(TPO) single -ply roofing membranes are used as roof
coverings in adhered and mechanically fastened
membrane roofing systems.
3.0 DESCRIPTION
3.1 General:
The EPDM, PVC and TPO Membrane Roofing Systems
described in this report consist of single -ply roofing
membranes, insulation where used, barrier board or slip
sheet where used, flashing, mechanical fasteners and
adhesives that are installed on a combustible or
noncombustible deck. See Table 1 for Carlisle product
trade names and corresponding product names for
Mule -Hide Products Company, Inc., WeatherBond, Versico
Incorporated and Kelly Company/2001 Inc.,,the additional
listees.
3.2 EPDM Membranes:
3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced
EPDM membrane available in 45-, 60- and 90 -mil
(1.14, 1.52, and 2.29 mm) thicknesses.
3.2.2 Sure -Seal FR: Sure -Seal FR is a black,
nonreinforced EPDM membrane with fire retardants,
available in 45-, 60- and 90 -mil (1.14, 1.52, and 2.29 mm)
thicknesses.
3.2.3 Sure -White: Sure -White is a white, nonreinforced
EPDM membrane available in a 60- and 90 -mil (1.52 and
2.29 mm) thickness.
3.2.4 Sure -Tough: Sure -Tough is a black, reinforced
membrane consisting of a polyester reinforcement
encapsulated between two EPDM membrane plies. It is
available in 45- to 75 -mil (1.14 to 1.90 mm) thicknesses.
3.2.5 Sure -Tough FR: Sure -Tough FR is a black,
reinforced membrane consisting of a polyester
reinforcement encapsulated between two EPDM
membrane plies with fire retardants. It is available in 45 to
60 -mil (1.14 to 1.52 mm) thickness.
3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is
a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced
EPDM bonded to a 5.5 -ounce -per -square -yard (0.18
kg /M2) polyester fleece.
3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK
is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white
EPDM bonded to a 5.5 -ounce -per- square -yard (0.18
kg /M2) polyester fleece.
/CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as
to arty finding or other matter in this report, or as to any product covered by the report.
�aoo
Copyright 0 2012 Page 1 of 10
ESR�1463 1 Most Widely Accepted and Trusted Page 2 of 10
3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or
90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM
bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2)
polyester fleece.
3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a
60 -mil (1.52 mm) non -reinforced EPDM bonded to a
7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece.
3.3 PVC Membranes:
3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and
Sure -Flex Elvaloy are 50-, 60-, or 80 -mil (1.27, 1.52, or
2.03 mm) membranes consisting of a polyester
reinforcement encapsulated between two plies of PVC.
The membrane is available in white, gray or custom colors.
3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure -
Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60-, or
80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a
fiberglass reinforcement encapsulated between two plies
of PVC. The membrane .is available in white, gray or
custom.colors.
3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex
Elvaloy FRS FleeceBACK: Sure -Flex 'FRS FleeceBACK
and Sure -Rex Elvaloy FRS FleeceBACK are the Sure -Flex
FRS membrane and the Sure -Flex Elvaloy FRS
membrane, described in Section 3.3.2 with a laminated
5.5 -ounce -per -square -yard (0.18 kg/m�) polyester fleece
backing.
3.4 TPO Membranes:
3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or
1.52 mm) membrane consisting of a polyester
reinforcement encapsulated between two plies of TPO.
The membrane is available in white, gray, tan or custom
colors.
3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld
membrane formulated with an additional flame retardant
for fire resistance at higher slopes. It is manufactured in
45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is
available in white, gray, tan or custom colors.
3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of
Sure -Weld HS membrane with adhesive.
3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same
formulation as the Sure -Weld membrane but comes in
72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is
the same formulation as the Sure -Weld HS membrane but
comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK
is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or
1.52 mm) thick with a laminated 5.5 -ounce -per -square -
yard (0.18 kg/m�) polyester fleece backing.
3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil
(1.14 mm) Sure -Weld HS membrane with a laminated
10 -ounce -per -square -yard (0.34 kg/m2) polyester fleece
backing.
3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is
the 60 -mil (1.52 mm) Sure -Weld HS membrane with a
laminated 10 -ounce -per -square -yard (0.34 kg /M2)
polyester fleece backing.
3.4.9 Spectro-Weld: Spectro-Weld its the Sure -Weld
membrane, described in Section 3.4.1, and Sure -Weld
EXTRA membrane, described in Section 3.4.4, formulated
with a brighter white color. It is manufactured in 45-, 60-,
72- or 80 -mil (1.14-, 1.52-, 1.83- or 2.03 -mm) thicknesses.
3.4.10 Spectro-Weld FleeceBACK: Spectro-Weld
FleeceBACK is the Spectro-Weld membrane with a
laminated 5.5 -ounce -per -square -yard (0.18 kg/m2)
polyester fleece backing.
3.5 Insulation:
See Tables 2 through 4 for insulations for use with specific
roofing systems. Foam plastic insulation, where used, must
have a flame -spread index of not more than 75 when
tested at the maximum thickness intended for use in
accordance with ASTM E 84. -
3.6 Barrier Board:
Barrier board, where used, must be either minimum
'/4 -inch -thick (6.4 ml G -P Gypsum Corporation
"DensDeck, minimum /4 -inch -thick (6.4 mm) Owens
Corning "Strataguard", minimum '/4 -inch -thick (6.4 mm)
USG "Securock," or minimum 1/2 -inch -thick (12.7 mm)
gypsum board. Barrier board must be UL- listed for roofing
applications or UL -classified gypsum board.
3.7 Slip Sheet:
The slip sheet, where used, must include Carlisle "FR
Base Sheet 1S or 2S," Elk "VersaShield Underlayment,"
Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or
FR 50."
3.8 Flashing:
Flashing must be provided in accordance with IBC Section
1503.2 or IRC Section R903.2, as applicable. Where
flashing is of metal, the metal must be corrosion -resistant,
minimum No: 26 gage [0.019 inch (0.483 mm)] galvanized
steel.
3.9 Fasteners:
Fasteners, used to mechanically attach insulation and
membranes to the roof deck, must be corrosion -resistant,
and must be Carlisle fasteners, plates or fastening bars,
unless otherwise noted in this report. Refer to Table 4 for
spacing of fasteners.
3.9.1 Sure -Seal HP Fastener: This is an epoxy -coated
steel screw used in combination with Carlisle's fastening
plates or bars to mechanically attach roofing insulation and
membranes to steel or wood substrate. Fastener length
must be selected to penetrate through the steel deck a
minimum of 3/4 inch (19.1 mm), and into the wood deck a
minimum of 1 inch (25.4 mm).
3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy -
coated steel screw used in combination with - Carlisle's
fastening plates or bars to mechanically attach roofing
insulation and membranes to structural steel members.
Fastener length must be selected to penetrate through the
steel member a minimum of 3/4 inch (19.1 mm.)
3.9.3 Sure -Seal HD 14-10 Fastener: This is a heavy-
duty, epoxy -coated steel screw used in combination' with
Carlisle's fastening plates or bars to mechanically attach
roofing insulation and membranes to concrete roof deck.
Fastener length must be selected to penetrate into the
concrete deck a minimum of 1 inch (25.4 mm). .
3.9.4 Sure -Seal HP Polymer Seam Plate: This is a
2 -inch -diameter (50 mm) polymer plate designed to be
used with Sure -Seal HP and Sure -Seal HD 14-10
fasteners to mechanically attach roofing membranes to the
roof deck.
3.9.5 Sure-Tite Fastener and ST Fastening Bar: This is
a heavy-duty, epoxy -coated steel screw and bar used to
secure reinforced EPDM membranes to steel or wood
deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by -10 -
foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume-coated
steel with prepunched holes 6 inches (150 mm) on center.
ESR -1463 I Most Widely Accepted and Trusted Page 3 of 10
3.9.6 HP -X Fastener: This is an epoxy -coated carbon
steel screw used in combination with the Piranha
Fastening Plate to mechanically attach TPO membranes to
steel or wood substrate. Fastener length must be selected
to penetrate through the steel deck a minimum of 3/4 inch
(19.1 mm), and into the wood deck a minimum of 1 inch
(25.4 mm).
3.9.7 Piranha Fastening Plate: This is a 23/8 -inch -
diameter galvalume-coated steel plate designed to be used
with HP -X fasteners to mechanically attach PVC and TPO
membranes to the roof deck.
3.9.8 HP-XTRA Fastener: This is an epoxy -coated
carbon steel screw used in combination with the Piranha
XTRA Fastening Plate to mechanically attach PVC and
TPO membranes to steel or wood substrate. Fastener
length must be selected to penetrate through the steel
deck a minimum of 3/4 inch (19.1 mm) and into the wood
deck a minimum of 1 inch (25.4 mm).
3.9.9 Piranha XTRA Fastening Plate:' This is a
23/8 -inch -diameter galvalume-coated steel plate designed
to be used with HP-XTRA fasteners to mechanically attach
PVC and TPO membranes to the roof deck.
3.9.10 OMG Inc. RhinoBond Plate: The RhinoBond Plate
is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm)
galvalume-coated steel plate, coated with a proprietary
adhesive and used with the HP -X fastener to mechanically
attach PVC and TPO membranes to the roof deck. The
adhesive bonds the plate to the underside of the
membrane.
3.10 Adhesives:
3.10.1 Sure -Seal 90-8-30A: Sure -Seal 90-8-30A is a high-
strength, solvent -based contact adhesive used to adhere
EPDM membranes to the insulation or substrate. It has a
coverage rate of approximately 60 square feet per gallon
(1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L)
containers and has a shelf life of one year.
3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base
120 is a high-strength, water-based contact adhesive used
to adhere EPDM and TPO membranes to the insulation or
substrate. It has a coverage rate of approximately 120
square feet per gallon (3 M2 A-). The adhesive is supplied in
5 -gallon (18.9 L) containers and has a shelf life of
one year.
3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex
PVC and Sure -Rex Low VOC PVC Bonding Adhesives are
high-strength, solvent -based contact adhesives used to
adhere PVC membranes to an insulation or substrate.
They have a coverage rate of approximately 60 square feet
per gallon (1.5 m IL). The adhesives are supplied in
5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld
Bonding Adhesive is a high-strength, solvent -based
contact adhesive used to adhere TPO membranes to an
insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 m2/L). The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding
Adhesive is a high-strength, solvent -based contact
adhesive used to adhere membranes to an insulation or
substrate. It has a coverage rate of approximately. 60
square feet per gallon (1.5 m /L). The adhesive is supplied
in 5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST
Adhesive Dual Cartridge, FAST Adhesive Box Sets,
Flexible FAST and FAST Bag -in -a -Box Adhesives are
two -component polyurethane adhesives used to adhere
FleeceBACK membranes and insulations to various
substrates. The adhesives have a coverage rate of
approximately 100 square feet per gallon (2.5 M2 /L). The
adhesives are supplied in 15 -gallon (56.7 L) and 50 -gallon
(189 L) drums, cartridge tubes or cylinders, and have a
shelf life of one year.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
IBC Section 1504.7, based on testing in accordance with
FM 4470.
4.0 INSTALLATION
4.1 General:
Installation of the EPDM, PVC, and TPO roofing
membranes described in this report must comply with the
applicable code, the manufacturer's published installation
instructions and this report. The manufacturer's published
installation instructions must be available at all times on
the jobsite during installation.
The substrate to which the membrane is to be applied
must be clean, dry, and free of frost, loose fasteners, and
other protrusions or contaminates that will interfere with the
adhesion or attachment of the membrane or that will
puncture the membrane. All materials must be protected
against contact with incompatible materials. Where
gypsum board is used as barrier board in the roofing
assembly, weather protection must be provided to prevent
damage to the gypsum board prior to application of the
roofing membrane.
The slope of the roof on which the single -ply membranes
are installed must not be more than the maximum slope
indicated for the particular assembly as listed in Tables
2 and 3.
Penetrations and terminations of the roof covering must
be flashed and made weather tight in accordance with the
requirements of the membrane manufacturer and the
applicable code.
4.2 Fire Classification:
4.2.1 New Construction: The adhered and mechanically
fastened EPDM, PVC, and TPO single -ply membrane
roofing systems, when installed in accordance with this
report, are Class A, B or C roof covering systems in
accordance with ASTM E 108 and UL 790, as noted in
Tables 2 and 3.
4.2.2 Reroofing: The existing deck must be inspected to
verify that the structure to be reroofed is structurally sound
and adequate to support and secure the roofing
membrane. Prior to installation of new roof coverings,
inspection by and written approval from the code official
having jurisdiction must be required.
Class A, B or C roof covering systems may be installed
over existing classified roof covering systems under the
following conditions without additional roof classification
tests, provided the resulting classification is the lower of
the new or existing roofing classification:
■ New uninsulated systems installed only over existing
uninsulated assemblies.
■ New insulated systems installed over existing
uninsulated systems only.
4.3 Wind Resistance:
4.3.1 New Construction:. The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
ESR -1463 1 Most Widely Accepted and Trusted Page 4 of 10
Metal edge securement for roofing systems must be
designed in accordance with ANSI/SPRI ES -1, complying'
with IBC Section 1504.5. The edge securement for
mechanically attached membranes was tested in
accordance with ANSI/SPRI ES -1 Test RE -1, using
Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003
aluminum] and Carlisle SecurEdge 3000 [0.040 -inch
(1.02 mm) 3003 aluminum] fascia systems. The maximum
allowable load for Carlisle SecurEdge 300 is 234 plf
(348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m).
4.3.2 Reroofing: Mechanically anchored systems may
be accepted based on the adequacy of anchors
penetrating through existing roof coverings into structural
substrates. Since the composition and/or condition of any
particular existing underlying material may vary widely,
reroofing with adhered systems is outside the scope of this
report.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
5.1 Installation must comply with the applicable code, the
manufacturer's published installation instructions and
this report. The instructions within this report must
govern if there are any conflicts between the
manufacturer's installation instructions and this report.
5.2 The adhered and mechanically fastened single -ply
membrane roofing systems must be installed by
professional roofing contractors who are trained and
approved by the manufacturer.
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with IBC Section 2603.4.1.5 or IRC
Section R314.4, as applicable.
5.4 Foam plastic insulation, where used, must bear the
label of an approved agency indicating that the foam
plastic has a flame -spread index of not more than 75
when tested at the maximum thickness intended for
use in accordance with ASTM E 84, subject to the
approval of the code official.
5.5 Design wind uplift pressure on any roof area,
including edge and comer zones, must not exceed
the allowable wind uplift pressure for the system
installed in that particular area. Refer to allowable
wind uplift pressures for systems as listed in Table 4.
5.6 The allowable wind uplift pressures listed in Table 4
are for the roof covering system only. The deck and
framing to which the system is attached must be
designed for the applicable components and cladding
wind loads in accordance with the applicable code.
5.7 When application is over existing roofs,
documentation of the wind -uplift resistance of the
composite roof construction must be submitted to the
code official for approval at the time of permit
application.
5.8 The roofing membranes are manufactured at Carlisle,
Pennsylvania; Greenville, Illinois; Tooele, Utah; and
Senatobia, • Mississippi, under a quality control
program with inspections by UL LLC (AA -668).
5.9 For buildings under the IBC, above -deck thermal
insulation board must comply with the applicable
standards listed in Table 1508.2 of the IBC.
6.0 EVIDENCE SUBMITTED
Data in accordance with ICC -ES Acceptance Criteria for
Membrane Roof Covering Systems (AC75), dated April
2007, (corrected December 2008).
7.0 IDENTIFICATION
Each roll of the roofing membrane must bear a label noting
the product name, the manufacturer's name (Carlisle
SynTec Incorporated) or the name of the additional listee,
the manufacturer's address or plant code, the ICC -ES
evaluation .report number (ESR -1463), and the name or
label of the inspection agency (UL LLC).
8.0 OTHER CODES
In addition to the codes referenced in Section 1.0, the
products in this report were evaluated for compliance with
the requirements of the following codes:
■ BOCe National Building Code/1999 (BNBC)
v 1999 Standard Building Code® (SBC)
■ 1997 Uniform Building Code TM (UBC)
For compliance under the above codes, see Sections 2
through 7 of this report, except revise the following
sections to read as follows:
3.8 Flashing:
Flashing must be provided in accordance with SBC
Section 1503.2, BNBC Section 1508.1 and UBC Section
1509, as applicable. Where flashing is of metal, the metal
must be corrosion -resistant, minimum No. 26 gage [0.019
inch (0.483 mm)] galvanized steel.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
BNBC Section 1505.4.2, and SBC Section 1504.6, based
on testing in accordance with FM 4470.
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 8.0 of this report, subject to the following
conditions:
See Sections 5.1 through 5.8, except revise Section 5.3 to
read as follows:
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with BNBC Section 2603.4.1.5, SBC
Section 2603.5.1.5, and UBC Sections 2602.4 and
2602.5.3, as applicable.
ESR -1463 -1 Most Widely Accepted and Trusted Page 5 of 10
wpSslFj�o low�;SSIFjFO
��C.?;-T,;:ji19•�L:£a",i}`"c.�5'� e�1�i?yii�,�;i.":•f1.41YCLi Y2+7'�u�6`e5.lt�.
oci. }7 . -S-a e}t 1c
i5
Ufit iun :?
pS3IFj�o
h:�itr7il;??•1r .la?'t'.�!.ug;.toi.� :�;r?s#ts'tF
_ ii ra;>v�ez�r�+x1:F'sr�:Frli�wbt��e..
FIGURE 1—INSPECTION AGENCY LABEL
e
ESR -1463 I Most Widely Accepted and Trusted Page 6 of 10
TABLE 1—PRODUCT NAMES
CARLISLE PRODUCT
MULE -HIDE PRODUCT
WEATHERBOND PRODUCT
VERSICO PRODUCT
KELLY CO./
NAME
NAME
NAME
NAME
2001 INC.
PRODUCT NAME
Sure -Seal
Mule -Hide Standard
WeatherBond RBR EPDM
Versigard
EPDM
Membrane
Sure -Seal FR
Mule -Hide FR EPDM
WeatherBond RBR FR EPDM
Versigard Nonreinforced
C-EPDM-C
Membrane
EPDM
Sure -Tough Reinforced
Mule -Hide Standard
WeatherBond RBR Standard
Versigard Reinforced
C-EPDM-CR
Reinforced EPDM
Reinforced EPDM Membrane
Sure -Tough FR
Mule -Hide FR Reinforced
Versigard FR Reinforced
C-EPDM-CR Type 1
Reinforced
EPDM
Sure -White
Mule=Hide White -on-
WeatherBond RBR White EPDM
Versigard Nonreinforced
EPDM RF - White
Black EPDM
Membrane
EPDM -White
Sure -Weld
Mule -Hide TPO-c
WeatherBond PRO TPO
Versiweld
Reinforced TPO /White
Membrane
TPO
Sure -Weld HS
Mule -Hide TPO-c (FR)
Versiweld ES
SAT-TPO
Mule -Hide SA-TPO
WeatherBond PRO PAS TPO
Versiweld OA TPO
Sure -Weld EXTRA
Mule -Hide TPO-c Extra
WeatherBond PRO TPO
Versiweld PLUS
Membrane
Sure -Weld HS EXTRA
Mule -Hide TPO-c Extra
Versiweld ES PLUS
(FR)
Sure -Weld FleeceBACK
Mule -Hide TPO-c Fleece
Versiweld VersiFleece
Back
Sure -Flex
Mule -Hide PVC
WeatherBond PRO PVC
VersiFlex Reinforced.
Membrane
PVC Membrane
Sure -Flex -FRS
Mule -Hide FRS PVC
VersiRex FRS
Membrane
Reinforced PVC
Membrane
Sure -Seal 90-8-30A
Mule -Hide Bonding
WeatherBond RBR LC -60 Bonding
G200SA Yellow
2001 Inc. Bonding
Bonding Adhesive
Adhesive
. Adhesive
Substrate Adhesive
Adhesive
Sure -Seal Aqua Base 120
Mule -Hide Water -Based
Aqua Base 120 Bonding Adhesive
Aqua Base 120 Bonding
Bonding Adhesive
Bonding Adhesive.
Adhesive
Sure -Weld Bonding
Mule -Hide TPO-c
WeatherBond PRO TPO Bonding
Versiweld Bonding
Adhesive
Bonding Adhesive
Adhesive
Adhesive
Sure -Weld Low VOC
Mule -Hide TPO-c Low
Versiweld LOW VOC
Bonding Adhesive
VOC Bonding Adhesive
Bonding Adhesive
Sure -Flex PVC Bonding
Mule -Hide PVC Bonding
WeatherBond PRO PVC Bonding
VersiFlex PVC Bonding
Adhesive
Adhesive
Adhesive
Adhesive
Sure -Flex Low VOC PVC
Mule -Hide Low VOC
VersiFlex Low VOC PVC
Bonding Adhesive
PVC Bonding Adhesive
Bonding Adhesive
FAST 100 Adhesive
Mule -Hide SP -100
FAST 100 Adhesive
Adhesive
FAST 100 LV Adhesive
Mule -Hide SP -100 -LT
FAST 100 LV Adhesive
Adhesive
ESR -1463 I Most Widely Accepted and Trusted Page 7 of 10
TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2'5
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANE/MAX. ROOF SLOPE
NO.
CLASS
OR SLIP SHEET
Sure -Weld, Spectro-Weld -'/4:12
Any of the following insulations,
Sure -Seal, Sure -Tough, Sure -White, Sure -
1 -inch min. to 6 -inch max.
thickness: Carlisle "SecurShield
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
1
A
Noncombustible
Polyiso", "Polyiso HP -H", Hunter
Sure -Weld FleeceBACK, Spectro-Weld
FleeceBACK /2:12
Panels "H -Shield" or
"H -Shield -CG"
Sure -White FleeceBACK, Sure -Flex, Sure -
Flex FRS /4:12
1/2 -inch -thick fiberboard 4, 1/2
Sure White FleeceBACK-3/4:12
inch -thick fiberboard or barrier
board (see Section 3.6) over 5
Sure -Seal; Sure -Tough - 1:12
2
A
Noncombustible
—
inch max Insulfoam EPS3, 1/2-
Sure -White, Sure -Seal FleeceBACK, Sure -
inch -thick fiberboard or barrier
Weld, Spectro-Weld, Sure -Weld HS, SAT -
board (see Section 3.6) over
TPO, Sure -Weld FleeceBACK, Spectro-Weld
System No. 1 insulations
FleeceBACK, Sure -Rex, Sure -Flex FRS -
1 /2:12
Sure -White FleeceBACK-3/4:12
Noncombustible or
Sure -White, Sure -Seal FleeceBACK - 11/2:12
Combustible - min.
Sure -Tough, Sure -Weld, Spectro-Weld, Sure -
3
A
15/32 -inch -thick
Barrier board
—
Weld FleeceBACK, Spectro-Weld
plywood or min.
(see Section 3.6)
FleeceBACK - 3:12
'/16 -inch -thick OSB.
Sure -Weld HS, SAT-TPO - 4:12
Sure -Seal FR, Sure -Flex, Sure -Flex FRS —
unlimited slope
Any of the following insulations,
Sure-Weld_Spectro-Weld - 1/4:12
Combustible - min.
Barrier board
1 -inch min.
Sure -Seal, Sure -Tough, Sure -White, Sure -
15/32 -inch -thick
(see Section 3.6) or
to 6 -inch max. thickness:
"SecurShield
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
4
A
plywood or min,
Slip sheet: 2 layers
Carlisle Polyiso",
Sure -Weld FleeceBACK, Spectro-Weld
7/16 -inch -thick OSB.
(see Section 3.7)
Polyiso HP -H",
"H
FleeceBACK - /2:12
Hunter Panels -Shield" or
Sure -White FleeceBACK, Sure -Flex, Sure -
"H -Shield -CG"
Flex FRS -3/4:12
Combustible - min.
15/32
Any of the following insulations,
Sure -Weld, Spectro-Weld, Sure -Weld HS,
5
C
-inch -thick
_
2 -inch min. to 6 -inch max.
"Polyiso
SAT -TPC, Sure -Flex, Sure -Flex FRS —
plywood or min.
'/16
thickness: Carlisle HP-
"H
unlimited slope
-inch -thick OSB.
H" or Hunter Panels -Shield"
Single layer of minimum 3.0" or
double layer of minimum 1.5"
6
A
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes - 1/2:12
Hunter Panels
"H -Shield -CG"
Single layer of minimum 1.9"
7
B
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes - 1/2:12
Hunter Panels
"H -Shield -CG"
For SI: 1 inch = 25.4 mm
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2See Section 3.10 for adhesive application rate.
3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below
min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
4Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. 1/2:12.
5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
ESR -1463 1 Most Widely Accepted and Trusted Page 8 of 10
TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANE/MAX. ROOF
NO.
CLASS
OR SLIP SHEET
SLOPE
Any of the following insulations, 1 inch min. to
"SecurShield
Sure -Tough, Sure -Weld,
Spectro-Weld, Sure -Flex, Sure -
1
A
Noncombustible
—
6 -inch max. thickness: Carlisle
"H
Flex FRS - /2:12
Polyiso" or "Polyiso HP -H", Hunter Panels
"H
Sure -Weld HS - 11/212
Shield" or -Shield -CG"
Sure -Tough FR - 2:12
'/-inch-thick fiberboard 3,'/z_inch-thick
Sure -Tough, Sure -Weld HS,
fiberboard° or barrier board (see Section 3.6)
Sure -Flex, Sure -Flex FRS - 1:12
2
A
Noncombustible
—
over 5 -inch max Insulfoam EPS2, '/z -inch -thick
Sure -Weld, Spectro-Weld -
fiberboard or barrier board (see Section 3.6)
1'/2:12
over System No. 1 insulations
Sure -Tough FR - 31/2:12
Sure -Weld, Spectro-Weld, Sure -
3
A
Noncombustible
—
To 5 -inch max: Insulfoam SP
Weld HS, Sure -Flex, Sure -Flex
FRS -'/2:12
Noncombustible or
4
Sure -Tough, Sure -Weld,
Combustible - min.
Barrier board
Spectro-Weld - 3:12
4
A
15/& -inch -thick
(see Section 3.6)
—
Sure -Tough FR - 31/2:12
plywood or min.
Sure -Weld HS, Sure -Rex, Sure -
_
6 -inch -thick OSB.
Flex FRS - unlimited
Combustible - min.
Barrier board
Any of the following insulations, 1 -inch min.
Sure -Tough, Sure -Weld,
16/
(see Section 3.6)
to 6 -inch max, thickness: Carlisle
Spectro-Weld, Sure -Flex, Sure -
5
A
�-inch-thick
plywood or min.
or Slip sheet: 2
"SecurShield Polyiso" or "Polyiso HP -H",
,
Flex FRS - /2:12
7/16 -inch -thick OSB.
layers, (see Section
Hunter Panels
Sure -Weld HS, 11 /2:12
3.7)
"H -Shield" or "H -Shield -CG"
Sure -Tough FR - 2:12
Combustible - min.Sure-Tough
- 1:12
15/3 -inch -thick
Slip sheet, 2 layers
Sure -Tough FR, Sure Weld,
6
A
plywood or min.
(see Section 3.7)
—
Spectro-Weld, Sure -Weld HS,
'/,6 -inch -thick OSB.
Sure -Flex, Sure -Flex FRS -
1 /2:12
Combustible - min.
Sure -Tough, Sure -Tough FR,
7
B
15/32 -inch -thick
Slip sheet, 1 layer
_
Sure -Weld, Spectro-Weld,
plywood or min.
(see Section 3.7)
Sure -Weld HS, Sure -Flex, Sure -
7/,6 -inch -thick OSB.
Flex FRS - 11/2:12
Combustible - min.
Any of the following insulations, 2 -inch min.
15/32 -inch -thick
to 6 -inch max. thickness: Carlisle
Sure -Weld, Spectro-Weld,
8
C.
plywood or min.
—
"SecurShield Polyiso" or "Polyiso
Sure -Weld HS, Sure -Flex, Sure-
ure-
7/,6-inch-thick
/, 6 -inch thick OSB.
HP -H", Hunter Panels "H -Shield" or H -Shield
Flex FRS - unlimited
CG"
Single layer of minimum 3 -inch or double
9
A
Combustible
—
layer of minimum 1.5 -inch Carlisle
EPDM, PVC, and TPO .
"SecurShield Polyiso" or
Membranes - 1/2:12
Hunter Panels "H -Shield -CG"
Single layer of minimum 1.9 -inch Carlisle
10
B
Combustible
—
"SecurShield Polyiso" or Hunter Panels "H-
EPDM, PVC, and TPO
Shield -CG" or single layer of an inverted G3
Membranes -'/2:12
cap sheet.
For SI: 1 inch = 25.4 mm.
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. -
2UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope -1:12) or below
min. '/-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/2:12.
4When these systems are used for reroofing or recovering, installation must be in accordance with Sections A.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
ESR -1463 1 Most Widely Accepted and Trusted Page 9 of 10
" TABLE 4—WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°''
SYSTEM
MAXIMUM
DECKS
INSULATION 5
MEMBRANE
MEMBRANE
MAXIMUM
MAXIMUM
NO.
ALLOWABLE
FASTENING
FASTENER
FASTENER
WIND UPLIFT
SPACING
ROW
(psf)
(inches)
SPACINGS
Foam plastic
insulation ?•
1
45
Noncombustible
1/zinch-thi k
fiberboard or
Sure -Tough
HP -X Fastener &
Metal Fastening Bar
12
6 ft 6 inches
barrier (ward
(See Sect. 3.6)
2
75
Noncombustible
Same as System No. 1
Sure -Tough
HP -X Fastener &
Metal Fastening Bar
6
6 ft 6 inches
3
52
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
Polymer Seam Plate
6
9 ft 6 inches
4
45
Noncombustible
Same as System No. 1
Sure -Tough
Sure-Tite Fastener &
12
9 ft 6 inches
ST Fastening Bar
5
30
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
12
9 It 6 inches
(75 mil)
Polymer Seam Plate
6
60
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
6
9 ft 6 inches
(75 mil)
Polymer Seam Plate
Sure -Weld,
HP -X or HP -Xtra
7
45
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
7 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
8
45
Noncombustible
Same as System No. 1
Sure -Weld,
Sure -Weld EXTRA, or
HP -Xtra Fasteners with
12
9 It 6 inches
Spectro-Weld
Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
9
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with
Piranha or Piranha Xtra
6
9 ft 6 inches
Spectro-Weld
Plates
Sure -Weld,
HP -X or HP -Xtra
10
67
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
7 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure Weld,
HP -X or HP -Xtra
11
30
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
11 It 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
12
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
11 It 6 inches
Spectro-Weld
or Piranha Xtra Plates
13
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
6
6 ft 4 inches
Piranha Plates
14
83
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
6
2 ft 11 inches
Piranha Plates
HP -X or HP -Xtra
15
30
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
18
6 It 4 inches
or Piranha Xtra Plates
HP -X or HP -Xtra
16
45
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
12
6 ft 4 inches
or Piranha Xtra Plates
17
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
12
2 It 11 inches
Piranha Plates
18
45
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
1 per 5.3 ftz
N/A
OMG RhinoBond Plates
19
60
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
1 per 4 to
N/A
OMG RhinoBond Plates
For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa.
'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso","Polyiso HP -H"
Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG".
2All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
3Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (f,) of 2500 psi. See Section 5.6 of this report.
°For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle
iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2.
5UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope -1:12) or below
min. 1/zinch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
6Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to V212.
ESR -1463 I Most Widely Accepted and Tnisted Page 10 of 10
Table 4 footnotes cont'd
When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
9 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened- roof
assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 pit (348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3.000 is 200 pif (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly.
TABLE 5—WIND RESISTANCE — ADHERED ASSEINBLIES5
SYSTEM
ALLOWABLE
DECK
INSULATION / MIN. THICKNESS'a
INSULATION
MEMBRANE
NO.
WIND UPLIFT
FASTENING
TYPE
(FIELD) (psf)
RATE
1
45
Combustible or
'/2 inch fiberboard, 15/32 inch OSB, or barrier board (See
1er 2 fl?
P
EPDM, PVC and TPO
Noncombustible
Section 3.6)
Membranes
2
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
"H "H
2
EPDM, PVC and TPO
45
Noncombustible
Panels -Shield" or -Shield -CG"/ 1.4 inch
'/cinch
1 per 3.2 ft
Membranes
withSecurock coverboard (optional)
3
45
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 4 ftz
EPDM PVC and TPO
Noncombustible
5/,rinch
per
Membranes
with Securock ooverboard (optional)
4
68
Combustible or
Carlisle "Polyiso HP -H" or "SecurShleld Polyiso"; Hunter
FAST Adhesive
FleeceBACK Membranes
Noncombustible
Panels "H -Shield" or "H -Shield -CG" / 1.0 inch
5
75
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" "H / 2.0 inch
1 1.6 ft2
EPDM, PVC and TPO
Noncombustible
or -Shield -CG"
with '/Z -inch Securock coverboard (optional)
per
Membranes
6
120
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
"H `H
1 Per 1 ft 2
TPO Membranes;
EPDM membranes (with
Noncombustible
Panels -Shield" or -Shield -CG" / 2.0 inch
noncombustible deck only)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
7
128
Noncombustible
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 per 1 If
EPDM and TPO Membranes
with'/2-inch Securock coverboard (optional)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
8
135
Noncombustible
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 per 1 ft2
FleeceBACK Membranes
with'/2-inch Securock coverboard (optional)
9
143
Combustible or
Noncombustible
'/2 inch DensDeck Prime
1 per 1 ft2
FleeceBACK Membranes
For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness, in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
zSteel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)). Concrete must have a minimum
compressive strength (Fc) of 2500.psi. See Section 5.6 of this report.
3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slopel:12) or below
min. '/z -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/2:12.
'When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to
the code official for approval at the time -of permit application. For reroofing or recovering, installation must be in accordance with IBC Section
1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. .
Find rated products - Cool Roof Rating Council
1 SEARCH RESULTS
Selected filters
Manufacturer: Carlisle Construction Materials Incorporated
4/16/14, 12:49 PM
PRINT EXPORT ALL PRODUCTS
CRRC PROD. ID MANUFACTURER. BRAND PRODUCT TYPE COLOR SOLAR REFLECTANCE THERMAL EMITTANCE SRI. MORE
MODEL
INFO
initial 3 year initial 3 year initial 3 year
0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 99 85
Incorporated: Sure -Weld Ply Thermoplastic
TPO White and Thermoset
Roofing
COOL ROOF RATING COUNCIL 1610 Harrison Street Tel (866) 465-2523 or Fax (510) 482-4421
Oakland, CA 94612 (510) 485-7175 Email: infoacoolroofs.or9
e:///Users/RAW/Desktop/Material%201nfo%20&%2OSpec./TPO%201nfo.%20&%2OSpec./TPO%2OCool%2oRoof%201nfo.webarchive Page 1 of 1
INSTALLATION CERTIFICATE: Residential Reroof CF -6R -ENV -01
Site Address:
77000 Avenida Fernando, La Quints, CA. 92253
Enforcement Agency:Permit
Number:
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate
applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibilityfor construction shall
prepare and sign this certificate for the entire construction. All applicable Mandatory Measures_ with check boxes are required to be checked to
ensure the mandatory measures have been met.
CEILING INSULATION
Rigid:' Brand Name:
Batt or Blanket Type: Brand Name:
Loose Fill Type: Thermal Resistance (R -Value):
Spray Foam Type: Brand Name:
Installed Actual Thickness (inches): Contractor's min installed weight/ftz
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value):
❑ §150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
❑ §118(a): Insulation installed meets Standards for Insulating Material.
❑ § 150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
lb
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
❑ Check this box if the newly installed roof is exempted from the roofing product "Cool Roof' requirements as indicated on the CF -1R -Alt- '
Reroof form for this project. Otherwise fill in the table below.
Responsi Person's Si nature:
Roof Slope
Product Weight
CSLB License:
Aged Solar
Thermal
688062
CRRC Product ID Number'
< 2:12 > 2:12
< 5lb/fe > 5lb/ft2
Product Type2
Reflectance 3,4
Emittance
0628-0002
.❑
1 ®
❑
11.
TPO
❑4
.70
.90
❑
1 ❑
❑
❑
❑4
1. CRRC-1 label information is available is on the package of the roofing product being installed and attach the CRRC label to this form.
2. Indicate the type of product is being used for the roof top, i.e. single -ply roof, asphalt roof, metal roof, etc.
3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory theft use the Initial Reflectance value frost the
sante directory and use the equation (0.2+0.7(pi�i1ia1 — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
ecommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
TO Cement -Based Roof Coating
❑ Other
DECLARATION STATEMENT
• I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct.
• 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative
of the person responsible for construction (responsible person).
• I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms
to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement
agency.
• 1 reviewed a copy of the Certificate of Compliance (CF -1 R) form approved by the enforcement agency that identifies the specific
requirements for the installation. I certify that the requirements detailed on the CF -1 R that apply to the installation have been met.
• I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building
permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a
signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building
owner at occupancy.
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
R D Winkle co. _
Responsible Person's Name:
Responsi Person's Si nature:
Ryan A. Winkle
CSLB License:
Date Signed:
Po 'o ith Company (Title):
688062
14-16-2014
ervisor
2008 Residential Compliance Forms . August 2009
Bin.#
Qty'of La Qulnta
Building 8t Safety Division
P.O. Box 11504,78-495 Caffe Tampico
1A.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: 77000 Avenida Fernando, La Quinta, CA, 92253
Owner's Name:. Mr. Doug Long
A. P. Number: 658240013
Address: 77000 Avenida Fernando
Legal Description:
City, ST, Zip: La Quints, CA. 92253
Contractor: R D Winkle co
Address: P.O. Box 476
Telephone: ,;
Project Description: New 60mil Thermoplastic Polyolefin (TPO)
City, ST, Zip: Thousand Palms, CA. 92276
roofing system with 1" EPS insulation board.
Telephone: 760-322-5144
- Y "
-f'� cl'-%�'�" "� �, � 'r=
The existing.BUR roof is to be recovered.
State Lic. 4: ' 688062
City Lie #:
The new roofing system will be mechanically fastene
Arch., Engr., Designer.
to 1-90 specifications.
Address:
City., ST, Zip:
`
Telephone: �R a "'` "
State Lie. #:f .�`
,- �i.�'r-N.z� .; �
Name of Contact Person: Ryan A. Winkle
Construction Type:. Roofing Occupancy:
Projecttype (circle one : New Add'n. Alter Repair Demo
Sq. Ft_: 3,500 4 Stories: 1 #Unit:
Telephone # of Contact Person:
Estimated Value of project: $ 29,772.00
APPLICANT: DO NOT WRITE BELOW THIS UNE
t!
Submittal
Req'd
"Reed
TRACXMG PERMIT FEES
Plan Sets
Pian Check submitted.
Item Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit, .
Truss Cates.
Called Contact Person
Plan Check Balance.
Title 24 Calc§.
Plans picked up
Construction '
Flood plain plan
Plans resubmitted'. .
Mechanical
Grading plan
2'' Review, ready for correctionsfissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review', ready for correctionsrasue
Developer Impact Fee
Planning Approval
Called Contact Person
A.IP.P.
Pub. Wks. Appr "
Date of permit issue
School Fees
Total Permit Fees