12-0590 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 12-00000590
Property Address: 77030 AVENIDA FERNANDO
APN: 658-240-010- - -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 13333
Applicant:
C�rw�n�1.
Td�v 4 4v Q"
Architect or Engineer:
�x
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 529976
(Date: — I I- 12—Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Codel or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001•:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
FRY, STANLEY & CHERYL
77030 AVENIDA FERNANDO
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/17/12
uRAMContractor: EFINANCE
DEVELOPMENT & CONST CO INC
72099 NORTH SHORE STREET 2012THOUSAND PALMS, CA 92276
(760)343-1800Lic. No.: 529976 EPTTq
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier ASSURANCE CO Policy Number WC966020801
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
9 3700 of the Labor I shall hwith comply with those provisions.
Date: ` 41 Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the -
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building constru ' n, and hereby authorize representatives
of this county to enter upon the above-mentioned pr r inspecti rposes.
Date: (�� 2 -Signature (Applicant or Agent):
Application Number . . . . . 12-00000590
------ Structure Information 165SF ADDITION/VB/RES-3/CLASS A -FR
[ENG] -----
Other struct info . .
. . . CODE EDITION 2010
FLOOD ZONE NO
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
165.00
Permit
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
153.00 Plan Check Fee
99.45
Issue Date . . . .
Valuation . . . .
13333
Expiration Date
3/16/13
Qty Unit Charge
Per
Extension
BASE FEE
45.00
12.00 9.0000
----------------------------------------------------------------------------
THOU BLDG 2,001-25,000
108.00
Permit
ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . . .
20.78 Plan Check Fee
5.20
Issue Date . . . .
Valuation . .
0
Expiration Date
3/16/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
165.00 .0350
----------------------------------------------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY
5.78
Permit
MECHANICAL
Additional desc . .
Permit Fee . . . .
19.50 Plan Check Fee
4.88
Issue Date . . . .
Valuation . . . .
0
Expiration Date
3/16/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
-----------------------------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
4.50
Permit
PLUMBING
Additional desc . .
Permit Fee . . . .
21.00 Plan Check Fee
5.25
Issue Date . . . .
Valuation . . . .
0
Expiration Date
3/16/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
LQPERMIT
Application Number . . . . . 12-00000590
Permit . . . . . . PLUMBING
Qty Unit Charge Per Extension
1.00 6.0000 EA PLB ROOF DRAIN 6.00
----------------------------------------------------------------------------
Special Notes and Comments
PATIO ENCLOSURES AT DINING AND MORNING
ROOMS - 165SF TOTAL/VB/RES-3/CLASS A -FR
(ENGINEERED] FOR CONDOMINIUM LOT
PURPOSES THIS PERMIT DOES NOT INCLUDE
ADDITIONAL SQUARE FOOTAGE BEYOND
EXISTING OVERHANGS. 2010 CALIFORNIA
BUILDING CODES.
September 17, 2012 9:36:35 AM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00
ENERGY REVIEW FEE 9.95
STRONG MOTION (SMI) - RES 1.33
Fee summary Charged
Permit Fee Total 214.28
Plan Check Total 114:78
Other Fee Total 12.28
Grand Total 341.34
LQPERMIT
Paid Credited Due
.00 .00 214.28
.00 .00 114.78
.00 .00 12.28
.00 .00 341.34
05/23/2012 WED 9:38 FAY La Quinta Bldg & 'Safety 12001/001
Bln.# I C1ij/ 'of.LQ QL(Itlta
11111tU49.8t Safety DhWbn
Petmif O P.O Box 1SO4,78-495 Calle Tampko
4 Qutnta, CA 92253 (160) 777-7012
Building Permit Application' and Tracking Sheet
PwjectAddtess: � � Owner's Name:. '
A P. Number Address: (� /��' Q
Legal Des i-iption: City, ST, '�-� AG \JY"f ���5
Contractor. Telephon : —
Project Description: O V t tJZ S C l A t MCS
city, ST'tip, �`fif1S. Qa P S �..�: c 4 PPzvw
Telephone. I S `. FT—
State Lic. # :'
. q'_/ City Lia #;
Arefi , 'Designer �� SNOt.*A e*A
Ad&r %: SS' r/\. 1 1"N�IQ
City., ST, Zip:S Q
Telephone(QO 2-� r ConsbuctionType: , Occupancy:
Project type (circle one) New Add'tt Apex Repair Demo
Name of Contact Person 'f\1c�Nu?�J Sq. Fi :# Stories: # Uait;;
Telephone # of Contact Peison_� Estimated Vafue of Projecfi1 Q C7
APPLICANT: DO NOT WRITE BELOW THIS WINE
Y Submittal Req'd Reed - TRACIi7PiG PE[tM1TFEES-
Plwn Sets 3 Plan Cheek submitted Amount
Stmdural Cales. 2 Bevlewed, ready to Plan Check Deposit.
Trust Cales. Called Contact Person (A Plan Check Balance.
Title 24 Calci. Z Plans picked up Caastraetion
Flood plain plan Plant resubmitted.'. Mechariital
Giadlog pian rd Review, ready r rrxtio t<i/ Electrical
Subeontactor List Called Contact Person Plumbing
Grant Deed Plans picked up I1 S.M.I.
H.O.A. Approval Plans raabmitted ✓ dlo '
IN UOUM.- ''� IRgvicw; ready fo rr o ae ` Developer Impact Fee
' r I
PlanaingApproval CalledcontactPerson f A.LP.P.
Pub..J.ks. APpr ' Date of permit issue
Seho6l Fees 5 `
TW ^ S Total Permit Fees
IPS Z PS. oft- 9�m *0
6111
S2 • vow:,.
�)
CERTIFICATE OF COMPLIANCE Q�J�rF�sr�o
Desert Sands Unified School District
47950 Dune Palms Road Q BERMUDA DUNES O
(n RANCHO MIRAGE d
Date 9/17/12 La Quinta, CA 92253 INDIAN WELLS
PALMDESERT
LA QUINTAy
No. 31411 (760) 771-8515Z
Q.IN®D .S7ti
Owner
Fry Residence
APN # 658-240-010
Address 77030 Avenida Fernando
Jurisdiction La Quinta
City
La Quinta Zip
Permit #
Tract #
No. of Units 1
Type
Residential Addition
Lot # No. Street S.F.
Lot # No. Street S.F.
Unit 1
77030 Avenida Fernando 165
Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 165 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Sherman Andrews Check No.
Name on the check Telephone
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
e
Fee collected /exempted by S ar, , McGilvrey Payment Recd
r Cver/Under
Signature C ~
NOTICE: Pursuant to Government Code Section 66020(d)(1), this ill erve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original- Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
72099 North Shore Street
Thousand Palms, CA 92276
Phone: 760-343-1800
Fax: 760-343-1880-1880
License #878197
DEVELOPMENT & Construction Company, Inc. Website: ram-development.com
August 15, 2012
Kay Hensel
City of La Quinta,
Building Dept
78-495 Calle Tampico
La Quinta, CA 92253
Dear Ms. Hensel,
This letter is to notify you that Randy Agor of Kayrand and Associates is no longer the architect on record
for the Fry Residence, located at 77-030 Avenida Fernando at the Santa Rosa Cove. The new architect
wilt be Brian Gotlieb of BG Structural Engineering: 43100 -Cook St Suite 203, Palm Desert, CA 92260,
Phone (760) 568-3553.
If you have any questions at all, please call me at (760) 343-1800.
1
2in
aaa
Executive Administrator
RAM Development & Construction Co., Inc.
P
ay
AUG 151-012
i
Associa.
Desert Resort Management
May 21, 2012
Stanley & Cheryl Fry
69 Pine Street
Peterborough, NH 03458
Re: Architectural Request / 77-030 Avenida Fernando
Los Estados @ Santa Rosa Cove. H.O.A.
Dear Mr. & Mrs. Fry,
The Los Estados @ Santa Rosa Cove Architectural Review Committee reviewed
your May 11, 2012 Architectural application to perforin the following extensions
in the monning room 94 sq ft and the dining room of.71 sq ft..
After consideration, the Committee has approved the submittal per the plans dated
5.11.12 as provided by Kayrand Associates Architect Randy Agor, contingent on
the following items:
1. Owner must obtain all permits through City of La Quinta; and required
inspections by the City and State code.
.2. Owner agrees to ensure that the. contractor keeps the streets, gutters and
adjacent properties clean.and free of dirt, trash, debris or other material
related to or caused by the work and clean up of all street spills on a daily
basis.
3. Construction hours are Monday through Friday from 8:00 AM — 5:00 PM
4. Owner will be held responsible for any road damaged caused by
contractors work or vehicles. We strongly recommend use of plywood
sheets under roof materials or stockpiles on the road as needed to protect
the road surface. This is especially important during this period of
extreme heat.
P.O. Box 14387 Palm Desert, CA 92255 Telephone 760.346.1161 Fax 760.346.9918 Web www.drmintemet.com
Associa' I The leader in community association management I www.associaonline.com
Fry
5/21/12
Page 2
5. Owner agrees to submit the Notice of Completion form at the end of the
proj ect.
If you have any questions please call me at (760) 346-1161. Thank you for your
patience during the review process.
Sin ly,
Carol C oun, CCAM®
Community Association Manager
For the Design Review Committee
Los Estados @ Santa Rosa Cove H.O.A.
Cc: Board ofDirectors%Architectural Committee
Kayrand Associates, Architect Randy Agor
255 N. El Cielo Rd.#140-143
Palm Springs, CA 92262
r BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Fry Residence
77030 Avenida Fernando
La Quinta, CA
Project Designer:
Randy Agor
255 N. EI Cielo, Suite 140-1,43
Palm Springs, Ca 92262
760-327-8535
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
cid i2•�
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
Job Number: APPROVE®
FOR CONSTRUCTION
DATE -11 II I I -,i V�►- BY r I
Date:
9/4/2012
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 20 1 2-0 9-04 71 1:35:22 . ID:
0
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
1
2
3
10
13
I EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655 1
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R
Project Name
Fry Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
9/4/2012
Project Address
77030 Avenida Femando =La Quinta
=-
California Energy Climate Zon
CA Climate Zone 15
I Total Cond. Floor Area
3,673
Addition
165
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures-- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. .
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity ( Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 3,508 Perim = 142'
Existing
Wall Wood Framed
R-11 1,982
Existing
Roof Wood Framed Attic
R-19 3,492
Existing
Roof Wood Framed Attic
R-19 165
New
Wall Wood Framed
R-19 502
New
Slab Unheated Slab -on -Grade
None 165 Perim = 15'
New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades
Status
Left (SE) 16.0 0.710
0.73 2.0 none Bug Screen
Existing
Rear (SVV) 11.0 0.710
0.73 2.0 none Bug Screen
Existing
Right (NM 172.6 0.710
0.73 2.0 none Bug Screen
Existing
Right (NVV) 64.0 0.710
0.73 2.0 none Bug Screen
Removed
Front (NE) 107.4 0.710
0.73 2.0 none Bug Screen
Existing
Skylight 16.0 0.710
0.73 none none None
Existing
Left (S) 62.0 0.710
0.73 2.0 none Bug Screen
Existing
Rear (W) 26.0 0.710
0.73 2.0 none Bug Screen
Existing
Right (N) 83.0 0.710
0.73 2.0 none Bug Screen
Existing
Left (SE) 30.0 0.710
0.73 none none Bug Screen
Existing
Left (SE) 48.0 0.710
0.73 2.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-09-04T11:35:22 ID:
Pa e 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Fry Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
9/4/2012
Project Address
77030 Avenida Fernando La Quinta —=-
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,673
Addition
165
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) -Factor SHGC Overhang Sidefins Shades Status
Front (NE) 112.0 0.590 0.45 2.0 none Bug Screen New
Front (NE) 30.0 0.710 0.73 2.0 none Bug Screen New
Right (NIM 108.0 0.590 0.45 2.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-09-04711:35:22 ID:
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Fry Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
9/4/2012
SPECIAL FEATURES,IINSPECTION CHECKLIST.
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by EnemySoft User Number: 2655 RunCode: 2012-09-04T11:35:22 ID: Pae 5 of 13
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Fly Residence
❑ Multi Family 10 Existing+ Addition/Alteration
9/4/2012
ANNUAL ENERGY USE SUMMARY
Standard -Proposed -Margin --
TDV kBtu/ft2 r
Space Heating 10.43 8.59 1.84
Space Cooling 127.94 126.96 0.98
Fans 27.89 27.55 0.34
Domestic Hot Water 10.84 10.84 0.00
Pumps 0.00 0.00 0.00
Totals 177.09 173.94 3.15
Percent Better Than Standard: 1.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 650 249
Fuel Available at Site: Natural Gas (SE) 750 156
Raised Floor Area: o (SM 410 37
Slab on Grade Area: 3,673 (Nle 1,480 364
Average Ceiling Height: 10.0 Roof 3,673 16
Fenestration Average U -Factor: 0.68 TOTAL: 822
Average SHGC: 0.65 Fenestration/CFA Ratio: 22.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
/4201
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sin Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Randy Agor
Address 255 N. EI Cielo, Suite 140-143 Name Kayrand Associates 9
City/State/Zip Palm Springs, Ca 92262 Phone 760-327-8535 Signed License # Date
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-09-04711:35:22 ID: Page 6 of 13
on
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Fry Residence
Building Type m Single Family ❑ Addition Alone
1 ❑ Multi Family 10 Existing+ Addition/Alteration
Date
9/4/2012
OPAQUE SURFACE DETAILS
-Surface - - --
Type Area
-U,--Insulation -- --
Factor Cavitv Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Slab
3,508
0.730 None
0
180 Existing 4.4.7-A1
Existing Living
Wall
334
0.110 R-11
135
90 Existing 4.3.1-A2
Existing Living
Wall
199
0.110 R-11
225
90 Existing 4.3.1-A2
Existing Living
Wall
407
0.110 R-11
315
90 Existing 4.3.1-A2
Existing Living
Wall
243
0.110 R-11
45
90 Existing 4.3.1-A2
Existinq Livin
Roof
3,4921
0.049 R-19
270
0 Existing 4.2.1-A4
Existinq Livin
Wall
290
0.110 R-11
315
90 Removec 4.3.1-A2
Existin Livin
Wall
138
0.110 R-11
180
90 Existing 4.3.1-A2
Existing Living
Wall
280
0.110 R-11
135
90 Remove 4.3.1-A2
Existing Living
Wall
174
0.110 R-11
270
90 Existing 4.3.1-A2
Existing Living
Wall
417
0.110 R-11
0
90 Existing 4.3.1-A2
Existing Living
Wall
450
0.110 R-11
315
90 Removec 4.3.1-A2
Existing Living
Wall
480
0.110 R-11
90
90 Removec 4.3.1-A2
Existing Living
Wall
70
0.110 R-11
135
90 Existing 4.3.1-A2
Existing Living
Roof
155
0.048 R-19
135
0 New 14.2.1-A16
Addition
Wall
52r
0.074 R-19
135
90 New 14.3.1-A5
JAddition
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
8.0 0.710 Default
0.73 Default 135 Existing
Double Metal Clear
Existing Living
2
Window
8.0 0.710 Default
0.73 Default 135 Existing
Double Metal Clear
Existing Living
3
Window
11.0 0.710 Default
0.73 Default 225 Existing
Double Metal Clear
Existing Living
4
Window
12.2 0.710 Default
0.73 Default 315 Existing
Double Metal Clear
Existing Living
5
Window
46.0 0.710 Default
0.73 Default 315 Existing
Double Metal Clear
Existing Living
6
Window
64.0 0.710 Default
0.73 Default 315 Removed Double Metal Clear
Existing Living
7
Window
97.9 0.710 Default
0.73 Default 315 Existing
Double Metal Clear
Existing Living
8
Window
16.5 0.710 Default
0.73 Default 315 Existing
Double Metal Clear
Existing Living
9
Window
25.0 0.710 Default
0.73 Default 45 Existing
Double Metal Clear
Existing Living
10
Window
16.5 0.710 Default
0.73 Default 45 Existing
Double Metal Clear
Existing Living
11
Window
5.9 0.710 Default
0.73 Default 45 Existing
Double Metal Clear
Existing Living
12
Window
30.0 0.710 Default
0.73 Default 45 Existing
Double Metal Clear
Existing Living
13
Window
30.0 0.7101D fault
0.73 Default 45 Existing
Double Metal Clear
Existing Living
14
ISkylight
16.0 0.710 Default
0.73 Default 270 Existing
Double Metal Clear
Existing Living
15Window
62.0 0.710 Default
0.73 Default 180 Existing
Double Metal Clear
Existing Living
16Window
1
20.0 0.710 Default
0.73 1 Default 270 Existing
Double Metal Clear
Existing Living
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
I Exterior Shade Type SHGC
Window
Hot Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
Hot Dist Len H t
1
Bug Screen
0.76
3.2 3.9 2.0 0.1
2.0 2.0
2
Bug Screen
0.76
3.2 3.9 2.0 0.1
2.0 2.0
3
Bug Screen
0.76
3.2 3.9 2.0 0.1
2.0 2.0
4
Bug Screen
0.76
3.2 3.9 2.0 0.1
2.0 2.0
5
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
6
Bug Screen
0.76
8.0 8.0 2.0 0.1
2.0 2.0
7
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
3.21 3.9
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
13
Bug Screen
0.76
3.2 3.9
2.0 0.1
2.0 2.0
14
None
1.00
15
Bug Screen
0.76
8.0 7.9
2.0 0.1
2.0 2.0
16
Bug Screen
0.76
8.0 7.0
2.0 0.1
2.0 2.0
Ener
Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-09-04T11:35:22 ID:
Page 7 of 13
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Fry Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 12 Existing+ Addition/Alteration
Date
9/4/2012
OPAQUE SURFACE DETAILS
`Surface
Area
-'U-^Insulation - Joint Appendix
Factor CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
-Type
Slab
165
0.730 None
0 180 New 4.4.7-A1
Addition
Wall
158
0.074 R-19
45 90 New 4.3.1-A5
Addition
Wall
292
0.074 R-19
315 90 New 4.3.1-A5
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm GlazingType
Location/Comments
17
Window
6.0 0.710 Default
0.73 Default
270 Double Metal Clear
Existing Living
18
Window
38.0 0.710 Default
0.73 Default
EExisting
0 Double Metal Clear
Existing Living
19
Window
29.0 0.710 Default
0.73 Default
0 Double Metal Clear
Existin Livin20
Window
16.0 0.710 Default
0.73 Default
0 Double Metal Clear
Existing Living
21
Window
30.0 0.710 Default
0.73 Default
135 Existing Double Metal Clear
Existing Living
22
Window
48.0 0.710 Default
0.73 Default
135 New Double Metal Clear
Addition
23
Window
48.0 0.590 NFRC
0.45 NFRC
45 New IWC 6200 /Low -E
Addition
24
Window
30.0 0.710 Default
0.73 Default
45 New Double Metal Clear
Addition
25
Window
64.0 0.590 NFRC
0.45 NFRC
45 New IWC 6200 /Low -E
Addition
26
Window
108.0 0.590 NFRC
0.45 NFRC
315 New IWC 6200 /Low -E
Addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hanq Left Fin
Len I Hat LExt RExt Dist Len
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
8.01 7.0
2.01 0.1 2.0 2.0
18
Bug Screen
0.76
3.2 3.9
2.0 0.1 2.0 2.0
19
Bug Screen
0.76
3.2 3.9
2.0 0.1 2.0 2.0
20
Bug Screen
0.76
6.5 7.9
2.0 0.1 2.0 2.0
21
Bug Screen
0.76
22
Bug Screen
0.76
8.0 6.0
2.0 0.1 2.0 2.0
23
Bug Screen
0.75
5.0 6.0
2.0 0.1 2.0 2.0
24
Bug Screen
0.76
5.0 6.0
2.0 0.1 2.0 2.0
25
Bug Screen
0.76
8.0 8.0
2.0 0.1 2.0 2.0
26
Bug Screen
0.76
9.0 12.0
2.0 0.1 2.0 2.0
Ener
Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-09-04711:35:22 ID:
Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Fry Residence
Building Type ❑'Single Family ❑ Addition Alone
❑ Multi Family IZI Existing+ Addition/Alteration
Date
9/4/2012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq I Altered Removed Volume Year Built
Living Zone Existing Living
3,508
35,080 1979
Addition
165
1,650
Totals 1 1651 3,508 01 0
HVAC SYSTEMS
System Name Qty. Heatin Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone 2 Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
(ft)o
ro
0
Q —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty- HP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number.- 2655
Run Code: 2012-09-04T11:35:22 ID:
Pae 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Fry Residence
Date
1 9/4/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
-the-compliance approach used. Morestringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulati ng Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
1 50 b : Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
,§150(e)IA: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or coolinq loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)18: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating s stems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro5.1 by EnergySoff User Number: 2655 RunCode: 2012-09-04T11:35:22 ID: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Fry Residence
1 9/4/2012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 byEnergySoft User Number: 2655 RunCode: 2012-09-04T11:35:22 ID: Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
Fry Residence
9/4/2012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-09-04711:35:22 ID: Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Fry Residence
Date
9/4/2012
System Name
Living Zone
Floor Area
3,673
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
2,273
0
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 70,000
72,433
3,595 1,161
58,801
Total Output Btuh 140,000
0
Output Btuh/s ft 38.1
6,142
4,178
Cooling System
0
0
Output perSystem 58,000
0
0 0
0
Total Output Btuh 116,000
0
3,595
0
Total Output Tons 9.7
1 6,142
4,178
Total Output Btuh/s ft 31.6
Total Output s ft/Ton 380.0
1 84,717
67,156
Air System
CFM perSystem
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
2,600
Existing HVAC
93,929 0
140,000
Airflow cfm/s ft
0.71
Airflow cfm/Ton
269.0
Outside Air %
0.0%-1
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
93,929 0 140,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
i-.
Outside Air
0 cfm Supply Fan
2,600 cfm
68 OF
68 OF 119 OF
Heating Coil
!
118 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/59°F 80/59°F 46/44°F
Outside Air
0 cfm Supply Fan Cooling Coil
2,600 cfm
80 / 59 OF
48 / 45 OF
29.6% ROOM I ll. `
1
78 / 58 OF