Loading...
0310-148 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date s: I:98 B f 12r31/2( ate/- Signature of Contractor �� '' J I. X OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date _ _ _ Sionature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (&.I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STATE, FUND Policy No. 101520-031 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Cydde, qs II fort'with comply withal os�e prouisions� ate: t�� `� a� Applicant U Warning: Failure to secure Workers' Comp ne sation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued'as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property four inspection purrppAes. Signature (Owner/Agent) -� 9--/ "/ . Date,/�'� BUILDING PERMIT PERMIT# 03X0-149 DATE VALUATION LOT TRACT �© S1tI(1,03��Cit3 14 , . PLY. 147 JOB SITE ADDRESS 77-$60 CALLIR =MtatIA APN 7:':'x-333-013 OWNER CONTRACTOR / DESIGNER / EN INEER 'MYLU5 917JCHrTL DONAUI LA1>rVYER A. 0. TORM COATI rrr_1UC7)'iON Y.O. BOX 1117 81-301 AVE 50 LA.Qti'.t'N'3'A j CA 92253 rAD10 CJI. 92201 (760)772.28" CDD 451 USE OF PERMIT EllNGLE 1?AMMY DW)U13.110 1641 S, F. S.FD PF.IW, IT i)00 HOT INC1.U17E, BLOCK WAIL PC1OIJSPA fall DRIVEWAY W.A.Y ARPROACH TRACT CONSTRUCTION I,441.01? Sp PORCH/PATIO 73.0037 EIARAOINCA.RPORT 508.00 SF Xr_ XED coo r CyF Cc>JX;fU(710r? 100,034M PIRMH7 FFXU 8i%i1N1WARY CONSTI RUCTION AEP 101 -0%1-4'19-000 $643.00 PLAN N CHECK PEE 101-000-4.39-318 Wrr.52 FEE DEPOSIT 101.00 -439,�318 425O.00 MEC'H.r NICAI. FBI, $54.00 E+GECTRICAI. FL's 101.00042( -000 $116.10 PI.L➢MBINCI IiEz 101-000-419-000 $136.00 ST.ROM MOTION FITZ REOID 1091.000.241.000 'V0,50 GRADIfiI0 FEE 101.000-423-000 DEVELOPER IMPACT ,SFR $2,40.4.00 PRECISE PLAIN 101 -WO -441-345 $1it13.0U ,SUB -TOTAL COIef91'k2iLf"T.T0N AND Pi.A1`vs CHECK $4,021,62 LESS .PRE -PAM VIES e -$250,00 IY rwl PF.Tofflor IrM . CIE NOW V1,771.62 OCT 2 9 2003 CITY OF LA QUINTA FINANCE DEPT. RECEIPT DATEy BY DAT FINAL INSPEC R INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs - Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O;K to Wrap �� F.A.U. Framing Compressor Insulation - Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final —T F7POOLS BLOCKWALL APPROVALS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines 7 Vv Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster- lasterSewer SewerLateral Pool Cover ' Sewer Connection Encapsulation Gas Piping Gas Test — L Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low. Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) j COMMENTS:; E �(/ �C l T3 SOcJ e T-' 'e J CERTIFICATE OF COMPLIANCE J�1Ft�sc Desert Sands Unified School District BERM - ,47950 Dune Palms Road Date 10/28/03 La Quinta f INDIAN WECA 92253 RAN AN WELLS LSMIRAGCf � No. 25130 (760) 771-8515 d� PALM LA gU1NTDESEnT �' �INDIO � O Owner Phyllis Stuchul & Donald Lameyer APN # 773-333-013 Address P O Box 1117 Jurisdiction La Quinta City La Quinta Zip 92253 Permit # 0310-148 Tract # BLK 147 Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 14 77860 Calle Chihuahua 1641 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Overpayment of $12.84 paid in cash. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, Cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,641 S.F. or $3,511.74 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Califomia Bank & Trust - Alex Torres Check No. 02839 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by a n cGilvrey Payment Recd$12.84 $3,524.58 Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this wWserve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting Certificate of Occupancy T -,df 4 4 a" Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and. the various ordinances of the City regulating building construction and/or use. Use classification SFD Occupancy GroupR3 BUILDING ADDRESS: 77-860 CHIHUAHUA Type of Construction: VN Owner of Building: A.O. TORRES CONSTUCTION Building Permit No.: 0310-148 Address: 81-301 AVE 50 City, ST, ZIP: INDIO 92201 By: KIRK KIRKLAND Date: 3-5-04 CONSPICUOUS PLACE Land Use Zone: RC CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF -4R Proj77itl j/ f/ kla Z-0 Date/ Proiect Address Builder Name Builder Cont ct Telephone -f, a -IV -57.23 Plan Number HERS ter Telephone Sample Group Number C ing Signature D e Sample House Number Firm: SC. d' SOGi eS /C o HERS Provider: �G,�f-�SSoG/rl%S Street Address: %; ��O ��'�G1 70YQ c,IYG� City/State/Zip: L9 0(.[/rla' CO 72,5 3 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: r Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form com ly with the diagnostic tested compliance requirements as checked on this form. Distribution system is fully'ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. L MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM F0 If fan flow is calculated as 400cfm/ton x number of tons enter /� calculated value here 6 If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) =., b Check Box for Pass or Fail (Pass=6% or less) ❑ ass Fail THERMOSTATIC EXPANSION VALVE (TXV) or Commission approved equivalent Yes ❑ No Thermostatic Expansion Valve (or Commission approved equivalent) is installed and Access is provided for inspection Yes is a pass ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values iri CF -1 R and design on plan. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1 R. Measured Fan Flow = Yes for both 1 and 2 is a Pass it- ❑ Pass Fail ❑ ❑ Pass Fail TITLE 24 REPORT Title 24 Report for: Alex Torres - 1641 SQ. FT. 77 860 Calle Chihuahua La Quinta, CA 92253 Project Designer: Site Designers & Builders 44-100 Monterrey Ave., Suite 201-D Palm Desert, CA 92211 - 760) 346 - 7989 Report Prepared By: S. L.O. Santiago Lopez-Ocampo P.O. Box 1137 Cathedral City, CA 92235 (760) 485-8927 rBUILDING OF LA QUINTA Job Number: & SAFETY DEPT, LQ03-90 APPROVED FOR CONSTRUCTION Date: 3/4/2004 gg116V 0 la 6e The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415)$83-5900. EnergyPro 3.1 By EnergySoft Job Number. L003-90 User Number. 5732 I ' TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 12 13 I EnergyPro. 3.1 By EnergySoft Job Number: LQ03-90 User Number. 5732 I Y Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Alex Torres - 1641 SQ. FT. 3/4/2004 Project Title Date 77 860 Calle Chihuahua La Quinta Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,641f? Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,041 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments TvDe tI-value (attic, Qaraae. tyDlCal. etc. R-38 Roof (R.38.2x4.24) Wood , 0.024 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) + 5/8" GYP Wood 0.085 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-13 Wall w/1" EPS Wood 0.059 Exterior Wall FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF Shading Yes / No Yes / No Front (South) 28.0 0.43 0.41 Bum Screen ❑ X❑ ❑ X❑ Front (South) 50.0 0.59 0.66 Bug Screen ❑ Q ❑ Q Left (West) 33.3 0.59 0.58 Bug Screen Q ❑ ❑ ❑x Left (West_ 33.3 0.59 0.58 Bug Screen ❑ o ❑ a Rear (North_ 56.0 0.59 0.66 Buq Screen ❑ 0❑ X❑ ❑ ❑ ❑ ❑ 1:1 E] El El 1:1 ❑❑ E] F1 El 1:1 El El 1:1 El ❑❑ Run Initiation i e: OX0410414:00:7 Run C 1078437617 EnerAyPro 3.1 By Ener Soft User Number: 5732 Job Number: LQ03-90 Page: 3 of 13 4 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Alex Torres - 1641 SQ. FT. 3/4/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 42 Setback HVAC Sp Iit System Gas/Elec Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback HVAC Split System Gas/Flet WATER HEATING SYSTEMS Rated 1 Tank Energy Facti 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 g, I ori. Less Small Gas Recircmme+Temp L_ 40 000 _so 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: S.L.O. Title/Firm: Site Designers & Builders Title/Firm: Santiago Lopez-Ocampo Address: 44-100 Monterrey Ave., Suite 201-D Address: P.O. Box 1137 Palm Desert, CA 92211 Cathedral City, CA 92235 Telephone: 760) 346 - 7989 Telephone: (760) 485-8927 Lic. #: cl 4'04 (signature (date) (signature) ---�^ (date) Enforcement Ag cry Name: Title/Firm: Address: Telephone: 'Certificate of Compliance: Residential (Addendum) CF -1 R Alex Torres - 1641 SQ. FT. 3/4/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The DHW Svstem "Standard Gas 50 pal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC Svstem "HVAC Split Svstem Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R.Pla�Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number. LQ0390 Page:5 of 13 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a'§150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill Insulation manufacturer's labeled R -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does a'§ not apply to exterior mass walls). [:]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and seated. §150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑%� §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. FX §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemaUextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping Insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (`) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) `§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fen systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114; Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between fiker and heater for future solar, cover for outdoor pools or spas. a. At least N' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. rV §115; Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 Iumenstwatt or greater for general lighting in kitchens. This general fighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. FRI §150(k)2: Rooms with a shower or bathtub must have either at least one luminairewith lamps with an efficacy of 40 IumensMratt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R Alex TprreS - 1641 SQ ET 3/4/2004 Project Title Date 77 660 Calle Chihuahua La Quanta Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check/Date Documen ation Author Telephone C:omptittzr Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance kBtu/sf- r Design Design Margin Space Heating 3.85 3.10 0.75 Space Cooling 41.15 40.30 0.85 Domestic Hot Water 14.83 14.45 0.37 Totals 59.82 57.85 1.97 Percent better than Standard: 3.3% RUILDIN COMPLIES Total Conditioned Floor Area: 1,641 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 12.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,410 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,641 ft 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt ennf— 1641 _ 0,024 —0 0 Wall 88 0.085 180 _90 Wall 189 0.085 go �90 nner 18 0.387 90 90 Wall 100 0.059 —90 —90 Wall 210 0.059 180 —90 Wall 40 _ 0.059 270 90 WAIT 40 0.059 180 �90 Door_ 20 _0_387 180 -90 Wall 40 _ 0.059 90_ _90 Wall 98 0.059 180 90 Wall 150 0.059 270 90 Wall 40 _ 0.059 180 _90 VVall 133 0.059 270 90 Wall 519 0.059 0 90 Wall 47 00.85_9f _go # of Units Solar Gains Y / N Form 3 Reference Thermostat Vent Zone Type Type Hgt. Area Condifinned Setback _2 nIA Location / Comments Run Initiation Time: 03104/0414:00:17 Run Code: 1078437617 EnergyPro 3.1 By Energysoft User Number. 5732 Job Number: LQ03.90 Page:8 of 13 'Computer Method Summary (Part 2 of 3) C -2R Alex Torres - 1641 SQ. FT. 3/4/2004 Project Title Date FENESTRATION SURFACES U- Overhang Left Fin Right Fin Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Front (South) 8 .0 0.430 0.41 180 _90 Mllgerd W ALUMINUM Low E Whole Hous _ 2 Window Front (South') 10.0 0.430 0.41 180 90 Milgard W. ALUMINUM Low E Whole House 3 Window Front (South) 25.0 0.590 0.66 180 90 Milgard W. ALUMINUM Low E Whole House 6 Window Front (South) 10.0 0.430 0.41 180 90 Milgard W. ALUMINUM Low E Whole House 5 Window Front (South) 25.0 0.590 0.66 180 90 Milgard W. ALUMINUM Low E Whole House 6 Window Left Nest) 33.3 0,590 0.58 270 90 Milgard W. ALUMINUM Low E Whole House Z Window Left ON0J) 33.3 0.590 0.58 270 90 Milgard W. ALUMINUM Low E Whole House 8 Window Rear (North) 10.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House 6 Window Rear (North) 6.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House 1.0 Window Rear (North) 20.0 0.590 0.66 0 90 Milgard W ALUMINUM Low E Whole House 11 Window Rear (North) 20.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 6.7 5.0 4.0 0, 4.0 4.0 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 I EnerayPro 3.1 By EnergySoft User Number. 5732 Job Number: LQ03 90 Pace:9 of 13 1 Computer Method Summary Minimum Distribution Type (Part 3 of 3) C -2R Alex Torres - 1641 SQ. FT. Efficiency and Location Duct Thermostat 3/4/2004 Project Title (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Date THERMAL MASS FOR HIGH MASS DESIGN __ 80%AFUE Ducts in Attic 4.2 Setback tem Gas/Elec Area Thick. Heat Pipe Pipe Insul. Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Minimum Duct F2 Insulation Efficiency Location Duct Thermostat Type Length Factor R -Val. Depth Location / Comments (SEER) (attic, etc,) R -Value Type Slab Perimeter 132 0.76 0.0 0 Whole House 12.0 SEE Ducts in Attic 4.2 Setback Slab Perimeter 61 0.76 0.0 — 0 Whole House Energy Facts 1 Tank Insul. HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace __ 80%AFUE Ducts in Attic 4.2 Setback tem Gas/Elec Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEE Ducts in Attic 4.2 Setback HVAC Split System Gas/Elec WATER HEATING SYSTEMS Rated' Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated input <- 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS HIS CALCULATION SUPERCEDES ALL PREVIOUS REPORTS, 10-15-03 Computer Method Summary (Addendum)' C -2R Alex Torres - 1641 SQ. FT. 3/4/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies lased on the adequacy of the special justification and documentation submitted. Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC Svstem "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential I HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Plan Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 03/04/04 14:00:17 Run Code: 1078437617 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03.90 Page: 11 of 13 4 PROPOSED CONSTRUCTION ASSEMBLY ENV-3 PROJECT NAME DATE Alex Torres - 1641 SQ. FT. 1 3/4/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME R-13 Wall w/1" EPS Stucco 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Insulation, Polystyrene, Smooth Skin 4 TYPE XWaII (check one) 5 W G W Ceiling / Roof 0.04 N FRAMING MATERIAL Wood 8 0 ? FRAMING % 15 %Framing o � 0.54 151/6 (16" o.c. Wall) 0.680 19.53 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Polystyrene, Smooth Skin 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6 0.04 7 0.37 8 2.08 9 0.54 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 5.000 5.000 12.999 3.465 0.450 0.450 0.04 1.68 0.37 0.62 2.08 0.26 0.54 0.680 0.680 19.53 10.00 KC KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. [ 0.0512 8.46 0.20 1.69 0.06 0.35 0.02 0.15 0.29 0.04 1.68 0.37 0.62 2.08 0.26 0.54 12.4 TOTAL HC 2 9 •NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0512 x 0.85 ] + [ 0.1000 x 0.15 1 / Rc 1 - (Fr -/o / 100) 11 Rf Fr% 1100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Pane: 12 of 13 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Alex Torres - 1641 SQ. FT. 3/4/2004 SYSTEM NAME FLOOR AREA HVAC Split System Gas/Elec 1,641 Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sqft) 39.6 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 29.3 Total Output (sgftrTon) 410.2 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 0.98 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I PEAK CFM Sensible Latent %tsible 803 15,489 0 527 20,715 0 774 1,036 0 0 0 0 0 0 0 0 0 774 1,036 17 1 22,787 YorkH4DH0481P3HUB16LO65U&H a 32,394 8,101 65,000 Total Adjusted System Output 32,394 8,101 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.40 107.6 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 107.0 �F 1600 cfm I ROOMS 70.0 OF 69.4 OF I i% Retum Air Ducts `i 11.0 / 77.6 OF 74.5 / 61.4 of 74.5 / 61.4 of ® 55.4 / 54.4 OF low Outside Air O 0 cfm Supply Fan 1600 cfm 74.5/61.4 °F Cooling Coil h Retum Air Ducts i Supply Air Ducts 55.9 / 54.6 of 48.7% R.H. ROOMS 74.0 / 61.3 OF I � I EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:13 of 13 TITLE 24 REPORT Title 24 Report for: Alex Torres - 1641 SQ. FT. 77-860 Calle Chihuahua La Quinta, CA 92253 Project Designer: Site Designers & Builders 44-100 Monterrey Ave., Suite Palm Desert, CA 922 lei 760)346 - 7 VY � 01 Job Number: LQ03-90 Date: 10/15/2003 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATEXO in%.. BY ST o FF(c& The EnergyPro c2prputer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by t California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. Energyfro 3.1 By Energy Soft Job Number: LQ03.90 User Number: 5732 11 ' TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number: LQ03-90 User Number: 5732 j Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date 77-860 Calle Chihuahua La Quinta Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,641 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,641 fl? Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deq Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) + 5/8" GYP Wood 0.085 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-13 Wall w/1" EPS Wood 0.059 Exterior Wall FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF Shadin Yes / No Yes / No Front (South) 28.0 0.43 0.41 Bug Screen ❑ x❑ ❑ X❑ Front (South) 50.0 0.59 0.66 Burl Screen ❑ NJ ❑ Q Left (West) 33.3 0.59 0.58 Bug Screen Q ❑ ❑ x❑ Left (West) 33.3 0.59 0.58 Bug Screen ❑ X❑ ❑ x❑ Rear (North) 56.0 0.59 0.66 Bug Screen ❑ Q ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time, 0 15/0322:03.36 Run Code: 1066280616 Ener Pro 3.1 By Ener Soft User Number: 5732 Job Number: LQ03-90 Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronlc or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fumare 80% AFUE Ducts in Attic 42 Setback HVAC _Sp it Sym Sac/pec Cooling Equipment Minimum Duct Cathedral City, CA 92234 Telephone: Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 5n aal or Less Small Gas Recirc/Time+Temp 1_ 40,000 50 0.52 n/a 12 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS THIS CALCULATI N SUPERCEDES ALL PREVIOUS REPORTS, 10-15-03 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Title/Firm: Site Designers & Builders Title/Firm: Santiago Lopez-Ocampo Address: 44-100 Monterrey Ave., Suite 201-D Address: 67-875 Pamela Ln. Palm Desert, CA 92211 Cathedral City, CA 92234 Telephone: 760) 346 - 7989 Telephone: (760) 485-8927 Lic. #.- (signature) : (signature) Enforcement Agency Name: Title/Firm: _ Address: Telephone: (date) �c��,o Lis O. tc� •�••o� (signature) (date) lEnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:4 of 13 1 Certificate of Compliance: Residential (Addendum) CF -1 R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justrticatton and documentation submitted. IPlan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor= 0.525. An EF below 0.58 requires an R-12 Extemal Blanket. The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a forth CF -6R. Plan Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 10/16/03 22.03:36 Run Code: 1066280616 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X]-§150(.): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does a"§ not apply to exterior mass walls). ❑ "§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiftbon/Exfittration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. FV §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ER§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures JAI §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. © §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. a§1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L003-90 Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) I150(m): Ducts and Fans 1. Ni ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 39' of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 Iumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 IumensMratt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling factures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5732 Job Number: LQ03-90 Page:7 of 13 'Computer Method Summary (Part 1 of 3) C -2R Alex orres - 1841 SQ FT 10/15/2003 Project Title Date 77-860 Calle Chihuahua l a Qi i*nta Project Address Building Permit # Santioptz- camnn (760) 485-8927 Documentation Author Telephone Plan Check/Date Computer Pprforrnance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.85 3.10 0.75 Space Cooling 41.15 40.24 0.91 Domestic Hot Water 14.83 14.45 0.37 Totals 59.82 57.79 2.03 Percent better than Standard: 3.4% BU LD OMPLIES Total Conditioned Floor Area: 1,641 ft2 Floor Construction Type: ❑ Raised Floor ❑R Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 12.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,410 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,641 ft 2 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units HVAC: Split System Gac/Flep 164 16 410 1 00 OPAQUE SURFACES Solar Act. Gains Type Area U -Fac. AZm. Tilt Y / N Roof 1 641 0024 _0 0 wall— 88 0 085 180 —9.0_ Wall 189 0 085 _go _go nnnr 18 0 387 90 90 Wall 100 0059 90 90 Wall 210 0 059 180 _gn Wall- 40 09% 270 .90 Wall 400 059 180 90 Door 20 --Qaa 180 _90 Wall 40 0.059 90 90 Wall 98 0 059 180 90 Wall 150 0 059 270. 90 Wall 40 0 059 180 90 Wall 133 0,059 —27n —9R Wall 519 0052 0 90 Wall 47 ---Jjla5- _g0 so Form 3 Reference Thermostat Vent Zone Type Type Hgt. Area C:pnditinned Sefhack —2 n/a Location / Comments Whole House Whnle Hnuse Whole Hn11Se Whole House Whole House Whole Hnuse Whole Houc_e Whnle House Whnle Hnuse Whnle Hnuse Whole 1 -Inure Whole Hnuse Whnle Hnuse Whnle Hnuse Whnle Hpuge Whnle HpLge I EnergyPro 3.1 By EnergySoft User Number. 5732 Job Number. LQ03-90 Page:8 of 13 1 'Computer Method Summary (Part 2 of 3) C -2R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date FENESTRATION SURFACES Window Overhang Left Fin # Exterior Shade Type SHGC Hgt Wd. Len. Hgt LEA REA Dist. Len. He 1 Bug Screen 0.76 U- 2 Act. Glazing Type Location/ # Type Bug Screen 0.76 Area Factor SHGC Azm. Tilt Comments _t_ Window Front _(South) 8.0 0.430 0 41 180 AQ M"lgard W_ ALUMINUM Low E Whole House 2 Window Front (South) 10.0 0.430 0.41 180 90 Milgard W. ALUMINUM Low E Whole House 3 Window Front (South) 25.0 0.590 0.66 180 90 Milgard W. ALUMINUM Low E Whole House 4 Window Front (South) 10.0 0.430 0.41 180 90 Milgard W. ALUMINUM Low E Whole House 5 Window Front (South) 25.0 0.590 0.66 180 90 Milgard W. ALUMINUM Low E Whole House 6 Window Leftesti 33.3 0.590 0.58 270 90 Milgard W. ALUMINUM Low E Whole House L Window Left (West) 33.3 0.590 0.58 270 90 Milgard W_ ALUMINUM Low E Whole House 8 Window Rear (North) 10.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House 6 Window Rear (North) 6.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House 1Q Window Rear (North) 20.0 0.590 0.66 0 90 Milgard W. ALUMINUM Low E Whole House -U Window Rear (North) 20.0 0,59Q 0.66 0 90 Milgard W. ALUMINUM Low E Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin # Exterior Shade Type SHGC Hgt Wd. Len. Hgt LEA REA Dist. Len. He 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 - 5 Bug Screen 0.76 _ 6 Bun Screen 0.76 6.7 5.0 4.0 0.1 4.0 4.0 _ 7 Bug Screen 0.76 8 Bug Screen 0.76 ` 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 I EnerovPro 3.1 By EnerovSoft User Number. 5732 Job Number. L003-90 Pane:9 of 13 1 Cb(hiouter Method Summary (Part 3 of 3) C -2R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 132 0.76 0.0 _0 Whole House Slab Perimeter 61 0.76 0.0 _Q Whole House HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value Type Comments -2t-! 7-711 IT11- ' 1 . , Nb MI -1i ' TR ■ 1 Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.2 SEE Ducts in Attic 4"2 Setback HVAC S Ip it System Gas/Elec WATER HEATING SYSTEMS Rated' Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution # in Input Cap, or Recovery Standby R -Value System Name Type Type Syst. (Stu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 10/15/03 22:03:36 Run Code: 1066280616 EnercYPro 3.1 BY EneraYSoft User Number. 5732 Job Number. LQ03-90 Pam: 10 of 13 `iCom'puter Method Summary (Addendum) 2-2R Alex Torres - 1641 SQ. FT. 10/15/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specked in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies daseo on me aaequacy or me special lusuricauon arta aocumentanon submitted. I Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. IThe HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R,plaj n j Field The HVAC System "HVAC Split System Gas/Elec" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EneravPro 3.1 By EnemvSoft User Number. 5732 Job Number. LQ03-90 Pane: 11 of 13 1 DROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Alex Torres - 1641 SQ. FT. 1 10/15/2003 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME R-13 Wall w/1" EPS Stucco 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor linsulation, Polystyrene, Smooth Skin 4 TYPE XWall (check one) 5 W G W Ceiling / Roof 0.04 c � N FRAMING MATERIAL Wood 6 Q Z FRAMING % 15 %o Framing /o 0.54 15% (16" o.c. Wall) 0.680 19.531 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) 1■ ■ t a ■ SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 linsulation, Polystyrene, Smooth Skin 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6 0.04 7 0.37 6 2.08 9 0.54 INSIDE SURFACE AIR FILM 1■ ■ t a ■ SUBTOTAI R -VALUE CAVITY R VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.0601 0.060 5.000 5.000 12.999 3.465 0.450 0.450 0.04 1.68 0.37 0.62 2.08 0.26 0.54 0.6801 0.680 19.531 10.00 KG Ki -HEAT CAPACITY (Optional WALL WEIGHT (lbslsf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. 8.46 0.20 1.69 0.061 0.35 0.02 0.15 0.29 0.04 1.68 0.37 0.62 2.08 0.26 0.54 12.4 TOTAL HC 2 9 NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergvPro 3.1 By EnergvSeft User Number: 5732 Job Number. LQ03-90 Page:12 of 13 1 C SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Alex Torres - 1641 SQ. FT. 10/15/2003 SYSTEM NAME FLOOR AREA HVAC Split System Gas/Elec 1,641 NGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sgft) 39.6 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuhisgft) 29.3 Total Output (sgft/ron) 4102 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 0.98 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfmisqft) 0.00 ote: values above given at ARI conditions 26.0 of 69.4 of Outside Air 0 cfm Supply Fan 1600 cfm 69.4 of 69.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK IICOILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible 803 15,489 0 527 20,715 0 774 1,036 0 0 0 0 0 0 0 0 0 774 1,036 17,038 0� 22 787 H4DH048/P3HUB16LO65 U&H 32,394 8,101 65,000 Total Adjusted System Output32,394 8,101 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 107.6 of Heating Coil h Retum Air Ducts`{ Supply Air Ducts 107.0 of ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 177.6 OF 74.5/61.4 OF 74.5/61.4 OF 55.4/54.4 OF © Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.9 / 54.6 of 1600 cfm 48.7% R.H. ROOMS 74.5/61.40F 74.0/61.3OF 3.1 User Number. 5732 Retum Air Ducts Job Number.. LQ03-90 13 of 13