Loading...
0204-016 (SFD)M LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty. of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business. and Professionals Code, and my License is in full force and effect. — - License # Lic. Class Exp. Date Date Signature of Contractor �� A OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their'sole compensation, will.,do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). . ( ) I am•exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereWaffirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation,. as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 4( )'°'I have and will maintain workers' compensation insurance, as required by S tion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier IilA.TE PtiND Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: ^ r,�f �+ '� Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety; for a permit subject to the conditions and restrictions set forth on his application. r 1. Each person upon whose behalf this application•is made & each person'at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize -7 epresentatives of this City to enter upon the above-mentioned property for in1� 11spect`ii)on purposes. Signature (Owner/Agent)' f! r Date 7: BUILDING PERMIT PERMIT 01t. DATE VALUATION LOT TRACT JOB SITE ADDRESS 7"1.0 C 'INUS1` APN 772—M—M , OWNER CONTRACTOR / DESIGNER / EN (NEER ROB C:.F?', OE7,1Z SIM VISTA I)EW1,0PUMMI COkP. 4'22•5Ji)13WOMION STMET PO P-07%. 3 344 `'PALM DFOMT CA 92260 LA QM14IA CA 92253 (760)772.2626 C31JI, 5393 USE O��`�yF PERMIT 977�> h p y / �q�g�}s �y RINGL RP0,�ka. I SitlV.i. LMG , . t.OT i.3lPI�MIT DOES SNOT ,INC~�.UDE OLOCK' `WA9�LS, P001� SRA. OR DRIVEWATAPPROACH. " CUSTOM CONSTRUCTION 4,E:110 V POR.CHIPATIO 1,033.00 Sr 0AI AGEMARPOda.'I' 1,012.00 Sr '�'k MKM COST OF �.'O�1,'2�4':dJ4: IO.N 43.0.484.60 prim -fur Y&d1,v(nMAwPY CON STR'0CTIONI SEE 101.000v418.000 $1,728.00 PLAN CHECK Z='EE 101-600-429-318 $1,4054.89 YISE'DEPOSIT 101.000-439-318 -m1ow o M,RCMAIVICALFEE; 101r-00.0-421-000 $13.141." CUKr3'R.ICA1, Fly 101-000-420-009 S26A.47 PLUM BINQ VEX 101-=)-419-000 $23.3.54 t STRONG M ION FEE - RESID 101-000-2,41-000 $41.03 011ADINO FEE 101 -M-411-000 MOO MVELOPER sMiPAC T FEE, 2 i,50,00 ARS W PLIBLIC F'1.,V21)' • REM 270-0705-000 $526,22 en _ 1 R-TOTAI, C. TRiii�°k�f3N AND A"l C".�1EOM $6,299-63 IYSV PRP. -PAM) :F' Ee'..f 41, ; 0a too Nil 1 1 L�Dt of LaQui�'A GI�Y FlNANCEDEP� R>>ECEIPT DATE 0;/11/ s 1 r +� B/yY/� /` DATE FINALED INSPECTO (I OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck CJ Exhaust Fans Z21 O.K. to Wrap F.A.U. Framing )/9 Compressor Insulation n Z. Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final _ Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines _ - �Z _ Heater Final Water Piping 2Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection _ Encapsulation Gas Piping Gas Test �— Appliances Final Final _ Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring -©y Low Voltage Wiring Fixtures Main Service ` _ 7._ Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: ' 4r,. Q � 1 G1 7-Yo—o' ` / FTN a -,r.0 w�'..�,. il'�i'R°''�'a':'�y,ra:"�..fi.:r:,�.,,nv..Yj•;"U'$!'.,"�"'`''FyYJ`�''"�}""`F",;YFl�„*'g�►�i►��'T`�r7�X�� a TAii�v 0 ui1'�,�cv BOX 1504 tdress jldjng / /1 UINT CAALI ORNIATAMPIO t1 LA QUINTA, CALIFORNIA 92253 Z,.. Mailin'-Address Z//b ���; `3%)i)`V / r Cit, Zip., Contractor eD �61X / �a zL State Lic.Fic.#5_� ity & Classif. 73 / `'� yzlc,.� / ,.- Arch., Engr,// /( Designer '� VEL 1. 7'1`" '�/ �(f Lic.`�� % I LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I amdidensed under proylsions of Chapter 9 (commencing with Section 7000) of Division 3 of•tKi ads ness•a.d Professions Code, and my license is in full force and effect. .� � /0-7 SIGNATURE '�' -/' Il / DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.S,Business and Professions Code: Any city or county which requires a permit'to construct, alter, improve, demolish, or repair any structure, prior to'its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). l: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose or sale.) 1 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law doesnot apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) V] I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) PoIN M o. Company t Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work. for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: N, after making this Certificate or Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. ($ec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct.; . I agree to comply with all city and county ordinances and state laws relating to building;'; construction, and hereby authorize representatives -of this city to enter the above-- . mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip APPLICATION ONLY ao 11LDING: TYPE'CONST. OCC. GRP. P. Number -/7a - 0(p 0 OD Igal Description LOTPE E 7XZ Project Description Sq. Ft 4u�� � Size (. - No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing 4' S.M.I. Grading Driveway Enc. Infrastructure \� . TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: 5 7- 'fD 20 A e C Du C. 4,� /v �_ WHITE = FINANCE YELLOW = APPLICANT (PINK = BUILDING DIVISION Certificate of Occupancy- City of La Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the. time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use.. For the following.- BUILDING ollowing: BUILDING ADDRESS: Use Classification: SINGLE FAMILY DWELLING Occupancy Group: R-3 Type of Construction: Owner of Building: SUN VISTA DEVELOPMENT CORP. Building Official 78-810 CITRUS vni Bldg. Permit No.: 0204-016 Land Use Zone: RL Address: 42-590 BRIGHTON STREET City: PALM DESERT, CA 92260 By: GARY SHOWALTER Date: FEBRUARY 11, 2003 POST IN A CONSPICUOUS PLACE LA QUINTA =ET.Y DEPARTMENT 7-7012 REQUEST�LINE 7-7153 uwner K(1H I 'ArV I A Ml 11' BUILDIN �f Permit Number 0204-016 POST ON JOB IN CONSPICUOUS PLACE LA QUINTA =ET.Y DEPARTMENT 7-7012 REQUEST�LINE 7-7153 uwner K(1H I 'ArV I A Contractor SUN VISTA DEVELOPMENT CORP. Permit Number 0204-016 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES 7�.rM CITRUS JOBADDRES S SFD . LOT15/PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL. SPA OR DRIVEWAY APPROACH. TYPE OF INSPECTION DATE lhsp. TEMPORARY' POWER `:sETbAcks U/G PLUMBING/ WASTE U/G ELECTRICAL] GROUNDING Y FOOTINGS /STEEL CONCRETE SLAB �­VCRETE U�T)L ABOVE SIGN -D __HOOF NAIL !PRE -ROOF PRE F zllil (COMBINATION) ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL 'INSULATION COVER NO WORK UNTIL ABOVE SIGNED .INTERIOR GYP BD. (DRYWALL) Z4 `EXTERIOR LATH GAS TEST. SEPTIC ABANDONMENT SEWER CONNECTION SEPTIC / GREASE INTERCEPTOR ONS FOOTINGS STEEL POOL / SPA I WATER FEATURE I PRE-GUNiTE / SETBACKS U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER (ALARMS / BARRIERS). FINAL INSPECTION TEMP. USE OF PERMANENT POWER1 ELECTRICAL I - MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT.TO TURN ON UTILITIES OR OCCUPY BUILDING I - AER WAY HOMES Order No. Escrow N(Recording Requested By Loan No. First American Title company WHEN RECORDED MAIL TO: Robert J. Capetz P.O. Box 1144 La Quinta, CA 92253 MAIL TAX STATEMENTS TO: SAME AS ABOVE DOC sit 2000-320016 08/18/2080 08:00A Fee:12.00 Page 1 of 3 Doe T Tax Paid Recorded In Official Records County of Riverside Gary L. Orso Assessor, County Clerk 8 Recorder 1111111111111111111111111111111111111111111111111111111 M $ U PAG@ SIZE DA POOR _ NOCOR SMF MISC. A R L COPY I LONG REFUND I NCHG EXAM ]Computed on the consideration--o—r value of property conveyed; OR Computed on the consideration or value less liens or encumbrances remaining at time of sale THE UNDERSIGNED GRANTOR determining tax -Firm Name APN: 1-1 2---(f:?c30_003 TRA: 020-051 GRANT DEED 3 FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, J CAPITAL PACIFIC HOLDINGS, LLC, a Delaware Limited Liability Company hereby GRANT(S) to Robert J. Capetz, a Single Man the real property in the City of La Quinta County of Riverside State of California, described as Lot 15 Tract No. 24890-4 (See Exhibit "A" Attached Hereto) Dared: V State of California ) ss. County of NNe" ) On W before me, W -b 4U_ personally appeared SW r personally known to me (or prove to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s) or the entity upon behalf of which the person acted, executed the instrument. WITNES MY HAND AND OFFIC SEAL Signature CAPITAL PACIFIC HOLDINGS,LLC, a Delaware limited liability company BY: CAPITAL PACIFIC HOLDINGS,INC., a Delaware go;poration, Managing Member BY: l /nr J. SCFIBNIo- T COMM- 81181994 NOTARY RaX - CALfOW ORANM COUNTY kh Comm. Exp (This area for official notarial seal) Date 7/11/02 No. 23363 Owner Rob Capetz Address 78810 Citrus City La Quinta Zip 92253 Tract # Type Single Family Residence Lot # No. Street Unit 1 0 78810 Citrus Unit 2 Unit 3 Unit 4 Unit 5 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units S.F. Lot # No. 1 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Comments 4835 Square Foot New Single Family Dwelling at Citrus - Grandfathered Agreement 4�'S�IFIEDSc�O > o QZ BERMUDA DUNES r RANCHO MIRAGE INDIAN WELLS PALM DESERT tja LA QUINTA �y INDIO y� 772-080-003 La Quinta 1 Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $628.00 X 1 S.F. or $628.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC 1st. Bank - Rob Capetz Check No. 65109 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Crystal Scott $628.00 $0.00 Payment Recti Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting G� P.O. BOX 1144 LA 9UINTA, CA 92253-1144 (760) 771-4722 FAX (760) 771-4922 u n Vista DEVELOPMENT CORPORATION City Of La Quinta, 78-495 Calle Tampico La Quinta, Ca 92253 -Ar vS S -7 To Whom It May Concern: I am requesting a permit from the city of la Quinta, as I have met -all of the city .requirements. I will.take responsibility for the Home Owners. Association where my home is located. Thank you in advance -for your assistance, J Rob Capetz REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE ❑ STRUCT. STEEL ASSEMBLY ❑ ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ OTHER I ❑ REINFORCED MASONRY ❑ FIRE PROOFING JOB L I us REPORT SEOUENCE NO. TAPE Of ST TIPy' PERMIT N0. DACt1/12,o, DAY OF WEEK MATERIAL DESCRIPTION SIX ARCHITECT INS`-��13-0�� HRS. CHARGED 9L� D1G e es ® ENGINEER S0 ¢,o� eV, ' ASSISTANTS MRS. CHARGED INSPECTION GENERAL SUB DATE CONTRALTO (f S CONTRACTOR �L ��� ( Ax 70 .A n� C:a COPY SENT TO CLIENT ❑ CON U ON NEXT PAGE ❑ PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF W KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. �<-&_4— e4 ff NATU E OF REGISTERSPE2) R A E OF EPORT REGISTER NUMBER REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE❑ (TRUCT. STEEL ASSEMBLY ❑ ` S# -V,99 ❑ POST TENSIONED CONCRETE O ASPHALT 0 ER ��S,in✓ ❑ REINFORCED MASONRY ❑ FIRE PROOFING JOB LOCATION o /� _ l ,� , J� _ ? y� 1' , 14 �,dy��/�C,(�J1' REPORT SEQUENCE N0. TVP MIRE r �/V PERMIT NO. DA DAY OF WEEK MATERIAL DESCRIPTION A -emsS V?4, (O �/ ARCHITECT I P NRS. CHARGED C` _1 C� ENGINEER ASSISTANTS HRS. CHARGED INSPECTION GENERAL^ ^ SUB DATE CONTRACTOR S `iv., CONTRACTOR (� 1� u -AS -z"( N 4 P5EV-uLb cots -� COPY SENT TO CLIENT ❑ CONTIN DON NEXT PAGE ❑ PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MV KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED, I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS GNATUI OF REGISTERED INSPECTOR d v �a 6(�- q 7S— E OF R PORT REGISTER NUMRFR 1r ommomommimi Immmmommimi --may f - a r Summit Structural Engineering P.O. Box 813 270 North Main Street i Donnelly, ID 83615 (866)862-8148 (208) 325-8148 Fax (208) 325-8149 October 2, 2002 Sun Vista Development, Inc. P.O. BOX 1144 La Quinta, CA 92253 Attn: Rob Capetz Subject: Structural Observation Lot 15 @ The Citrus La Quinta, CA. Dear Rob, Per your superintendent Mark's request, we visited the subject job site on October 2, 2002 to perform a structural observation. While we were at the job site, we found several omissions and deviations from the plans. All missing items were installed while we were at the job site and at that time we found the structure to be in general compliance with the structural design concept. e } ' If you have any questions, please give me a call. Yours truly, SUMMIT STRUCTURAL ENGINEERING N° C`' ,^ 103 �P, 1210 Benjamin Herbst, P.E. BH gAMy Documents\2002\jobfiles\Sv-171\171—field 1(cert).doc Residential. Commercial. Industrial. Land Development A YOUNG ENGINEERING SERVICES 47-159 YOUNGS LN. INDIO, CA. 32201 PHONE 760-342-9214 FAX 760-342-6164 Rev: 510300 User: KW_. ,715, Ver 5.1.3.22Jum1999. Win32 Description Title : Dsgnr: . Description Scope : Multi -Span Timber Beam Job # Date: 11:44AM, 19 JUN 02 Page 1 General Information Douglas Fir - Larch, No.1 Fb : Basic Allow 1,350.0 psi Elastic Modulus 1,600.0 ksi Spans Considered Continuous Over Support Fv : Basic Allow 85.0 psi Load Duration Factor 1.000 Calculations are desioned to 1997 NDS and 1997 UBC Requirements Timber Member Information in -k 74.5 3.0 Description ft 2.40 4.55 Span ft in -k 7.50 5.50 Timber Section in -k 6x12 6x12 Beam Width in psi 5.500 5.500 Beam Depth in psi 11.500. 11.500 End Fixity 2.78 Pin - Pin Pin - Pin Le: Unbraced Length ft k 0.00 0.00 Member Type k Sawn Sawn Loads psi 87.3 47.2 Fv : Allowable psi0 Live Load Used This Span ? Yes Yes Dead Load #/ft 60.00 346.00 Live Load #/ft 208.00 Dead Load #/ft 484.00 Live Load #/ft 352.00 Start ft 2.000 End ft 7.500 5.500 Point #1 Dead Load lbs 1,540.00 Live Load lbs 1,120.00 @ X ft 2.000 Results Mmax @ Cntr in -k 74.5 3.0 @ X = ft 2.40 4.55 Max @ Left End in -k 0.0 -65.8 Max @ Right End in -k -65.8 0.0 fb : Actual psi 614.7 542.6 Fb : Allowable psi 1,350.0 1,350.0 2.78 Bending OK Bending OK Shear @ Left k 3.13 2.52 Shear @ Right k 4.58 0.53 fv : Actual psi 87.3 47.2 Fv : Allowable psi0 85.0 -0verStress Shear OK Reactions & Deflection ft DL @ Left 1� k Moment, 1.89 4.32 LL @ Left k lbs 1.24 2.78 Total @ Left k 3.13 7.10 DL @ Right k 4.32 0.35 LL @ Right k 2.78 0.18 Total @ Right k 7.10 0.53 Max. Deflection in -0.046 0.007 @ X = ft 3.30 1.72 Query Values cation 0.00 -65.8 2.5 0.0000 ft 0.00 Moment, in -k 0.0 Shear lbs 3.1 Deflection -in 0.0000 04/30/2002 14:43 c- CUSTOMER DATE SQUARE= FEET GD DW SMALL APPLIANCES 1ACRO OVEN COOKTOP-ELECTRIC COOKTOP-GAS WASHER DRYER -ELECTRIC DRYER -GAS FAU POOL FUTURE LANDSCAPE Ft7TURE TOTAL -WATTS 1st 10,000 WATTS REMAINDER A/C COMPRESSORS TOTAL DIVIDED 13Y USE - 7765449 HEGGE ELECTRICAL PAGE 05 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAM—'7 lb8a) SUN VISTA t3EV. CAPETZ RESIDENCE jAprU 30..2002- .4,825 0;2002 .4,825 3 14,475 1,500 2 31ow 1,500., 1 1,500 1:,500 2 , . :3,000. I ,500 1 1;500 8;000 1 %ow 8,000 1 8,000 1,500 0 0 1,600 1 1,500 5,000 1 5,000 1,500 0 0 1,500 4 6,000: 4,500 1 4,5N 3.00tl. 1 3,000 59;47& PERCENT WATTS 400% 10.000 -70,000 401, 49,475 19,790 8,000 4 100% 32,000 61;790 240 V 257AS83 AMP'S 400 04/30/2002 14:43 7765449 s 490 AMP SPLUd•HMS HEDGE 'ELECTRiCA� `3.0 CV WE* 04 Ci MM @ WATER BgM 240 m �0AMPSUBPARI UAINHOUSE 3-OGiiX3 + �¢ 2'�flG /CONDUIT AS PER IID MP- 6z MRS, ROB CAPETZ LOT# 15 CITRU$ ESTATES PACE 06 ��13•y�l 'TSL Cir) (� y1, 000 T R-ru , CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION )A W BY 1BBro Cmws r �7,9d SD, 0,00 13� i1 ,q ,`(rL oxk-70p 6r,000 11, 5-°j,0 q of:?+ I LL r�Q13T lit - 2f, cm A3-7- aiwoo erj off• S3 G� r L CE MAUPH) TITLE 24 ENERGY CALCULATIONS, INC. 7544 E. SADDLEHILL TRAIL, ORANGE, CA 92869 (714) 771-1507 Owner: Sun Vista Development Corp. 51-370 Avenida Bermudas, #2 La Quinta, CA 92253 Designer: Sun Vista Development Corp. 51-370 Avenida Bermudas, #2 La Quinta, CA 92253 March 25, 2002 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT L Project: "Citrus Course" -1$Ei0 C4T)2 )S. , Lot #15 La Quinta, California k• . STATEMENT OF CONFORMANCE This Calculation contains all the building features and performance specifications required for compliance. by the California Code of Regulations Title 24, Part 1, Administrative Requirements; Part 6, Building Energy Efficiency Standards; and portions of Title 20, Appliance Efficiency Standards, and AB 970. When these features are incorporated into the architectural plans the design will be in compliance with the 2001 Energy Efficiency Standards as they apply in Climate Zone 15 , using MICROPAS6 Version 6.01, a California Energy Commission approved computer performance method program. Certified Energy Analyst Rick Maurer r r NR 98-90-528 r r R 98-90-136 CABEr- C California Association of Building Energy Consultants Prepared By: Rick Maurer Energy Plans Examiner Certificate No. RES -88-1006 and NRE-88-1052 California State License No. 502290 C20 ** SUMMARY SHEET ** Proiect: Sun Vista Development -- La Quinta, CA Zone: 15 "Citrus Course" Lot #15 Wall Insulation: R-19 (Min. 2X6 Exterior Walls Required) Ceiling Insulation: R-38 Radiant Foil Barrier: Not Required Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL PANE except the following; which is SINGLE: ** Entry Doors ( s5e. NOTES beL ow) Hard Surface Flooring: Minimum Furnace AFUE: Total Sq. Ft. = 1,791 Entry/Halls/Powder: Wet Bar/Pantry: 98 Service: 58 80% AFUE 512 Kitchen/Dining: 378 Great Room: 548 Library: 197 Minimum Heating Capacity: 131,535 BTUH Minimum A/C SEER: 12.0 SEER (TXV Required) A/C Tonnage: 15.0 Tons (Min.Sens.=110,516 @ 115°) Duct Insulation: , R-6.0 (Duct Leakage Test Required) Note(s): 1) Each water heater specified will require an external insulation blanket of,R-12 or greater. 2) This house requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) Each water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows and sliding glass doors will have wood frames with metal cladding and an NFRC U -factor of .55 or less -and a SHGC of .45 or less with high performance Low -E glass. 5) All hinged french doors will have wood or fiberglass frames with dual pane glass and default values. 6) The entry doors will have wood frames with single pane glass and default values. MANDATORY MEASURES CHECKLIST: RESIDENTIAL (page); of 2) MF -1R Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: - • §150(a): Minimum R-19 ceiling insulation. § 150(b): Loose rill insulation manufacturer's labeled R -Value. • §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -Factor in metal frame walls ✓ does not apply to exterior mass walls). • §150(d): Minimum R-13 raised floor insulation in framed floors. § 150(1) : Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no IF: REQ'O �! greater than 2.0 nm/inch. § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field -fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §I50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. IF QEQ'p. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: §I 10-§ 113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ✓ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. § 1506): Pipe and tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 ✓ external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55' F insulated. (TABLE i.—T) REFER. SUCTION LINE MJ N. R-3 INS. 6. Piping insulated between heating source and indirect hot water tank. Compliance Forms August 2001 A-5 MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) MF -1R Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) • § 150(m): [huts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirement of the 1998 CMC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support v platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment. 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: / a. At least 36 of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no ✓ continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr § 118 (f): Cool Roof material meet specified criteria Lighting Measures: § 150(k)l.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. § 150(k)2.: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this / V requirement allowed in § 150(k)2.; and incandescent recessed ceiling fixtures are IC (insulation cover) approved. Compliance Forms August 2001 A-6 MANDATORY MEASURES The following iterns represent the MANDATORY REQUIREMENTS for ALL LOW-RISE RESIDENTIAL buildings and shall appear as notes on the plans: (A) Before the building may be occupied, installation certificates (CF -6R) for manufactured devices regulated by the Appliance Standards or Part 6 shall be posted adjacent to the building permit(s). Certificate shall: 1. Identify features required to verify compliance with the Appliance Standards and Part 6; 2. Include the statement indicating that the installed devices conform to the Appliance Standards and Part 6 and the requirements for such devices given in the plans and specifications approved by the local enforcement agency; 3. State the number of the building permit under which the construction or installation was performed. Sec. 10-103 (a) (3) (B) The builder shall provide the building owner, manager, and the original occupants the appropriate Certificate(s) of Compliance (CF -1R) and a list of the features, materials, components, and mechanical devices installed in the building, and instructions on how to use them efficiently. Sec. 10-103 (b) (1) (C) After installing wall, ceiling, or floor insulation, the installer shall post in a conspicuous location in the building a certificate signed by the installer stating that the installation is consistent with the plans and the requirements of Section 10-103 (a) (2) (A) and conforms with the requirements of Part 6. The Certificate (IC.;, I) shall also state the manufacturer's name and material identification and the installed R -value. Sec. 10-103 (a) (4) (D) Manufactured fenestration products shall be certified for overall U -factors and overall SHGC as rated by the National Fenestration Rating Council's NFRC 200: 1. Have a clearly visible temporary label, not to be removed before inspection by the enforcement agency, listing the certified U -factors, solar heat gain coefficient (SHGC) of the product and the method used to derive those values. Also, the label should indicate compliance with air infiltration requirements of Section 116 (a) 1. 2. Have a permanent label meeting the requirements of Section 10-111 (a) (2). Sec. 116 (a) (E) Field fabricated skylights and windows, and exterior doors, shall be caulked between the fenestration product and the building, and shall be weather-stripped. EXCEPTION: Unframed glass doors and fire doors. Sec. 116 (b) (F) Joints and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weather-stripped, or otherwise sealed to limit infiltration and exfiltration. Sec. 117 (G) All insulating material shall be installed in compliance with the flamespread rating smoke density requirements of Section 707 of the UBC. Sec. 118 (c) (H) Heat pumps with supplementary electric resistance heaters shall have controls: 1. That prevent supplementary heater operation when the heating load can be met by the heat pump alone; and 2. In which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. Sec. 112 (b) (I) Masonry or factory -built fireplaces shall have the following: 1. Closeable metal or glass doors covering the entire opening of the firebox. 2. A combustion air intake to draw air from the outside of the building directly into the firebox, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight fitting damper or combustion air control device. EXCEPTION: Not required if fireplace is installed over a concrete slab and will not be located on an exterior wall. 3. A flue damper with a readily accessible control. EXCEPTION: When a gas log, log lighter, or decorative gas appliance is installed in a fireplace, the flue damper shall be blocked open if required by the manufacturer's installation instructions or the State Mechanical Code. 4. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Sec.150(e) (n All heating and/or cooling systems other than wood stoves shall have an automatic thermostat with a clock mechanism or other setback mechanism that shuts the system off during periods of non-use and that allows the building occupant to automatically set back the thermostat set points for at least 2 periods within 24 hours. Sec. 150 (i) (K) The air handling duct system shall be constructed, installed, sealed and insulated as provided in Chapter 6 of the Uniform Mechanical Code. (Must be insulated to a minimum installed level of R-4.2 or be in conditioned space) Sec. 150 (m) (L) All fan systems exhausting air from the building to the outside shall be provided with backdraft or automatic dampers to prevent air leakage. Sec. 150 (m) 7 (M) Storage gas water heaters with an energy factor <0.58 shall be externally wrapped with insulation having installed thermal resistance of R-12 or greater. Sec. 150 6) IA (l) Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water heating systems, shall be externally wrapped with insulation having an installed thermal eesistance of R-12 or greater or have internal insulation of at least R-16 and a label on the exterior of the tank showing the insulation R -value. Sec. 150 6) 1B (0) Duct system openings shall be sealed with mastic, tape, aerosol sealant, or other duct closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B including collars, connections and splices. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Sec. 150 (m) (P) Building cavities shall not be used for conveying conditioned air. The return air plenum must be fully ducted from the equipment to the conditioned space. Sec. 150 (m) (Q) Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. Sec. 150 (m) (R) Piping, buried or unburied, for recirculating sections of domestic hot water systems, piping from the heating source to the storage tank for an indirect -fired domestic water heating system, cooling system piping below 55° F, and the first five feet of hot and cold water pipes from the storage tank for non -recirculating systems shall be thermally insulated in accordance with Table No. 1-T. Sec. 150(m) (S) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have efficacy of not less than 40 lumens per watt. (Fluorescent type lighting will meet this requirement). Sec. 150(k) (T) In climate zones 14 and 16 a vapor barrier shall be installed on the conditioned space side of all insulation in all exterior walls, unvented attics, and invented crawl spaces to protect insulation from condensation. Sec. 150 (g) (U) Any new low-rise residential building shall meet the following minimum requirements: 1. Ceiling Insulation. The opaque portions of ceilings separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a. or b. below: a. Ceilings shall be insulated between framing members with insulation resulting in an installed thermal resistance of R-19 or greater for the insulation alone. ALTERNATIVE to Section 150 (a) 1: Insulation which is not penetrated by framing members may meet an R -value equivalent to installing R-19 insulation between framing members and accounting for the thermal effects of framing members. b. The weighted average U -value of ceilings shall not exceed the U -value that would result from installing R-19 insulation between framing members in the entire ceiling and accounting for the effects of framing members. (.051 Max.) 2. Loose Fill Insulation. When loose fill insulation is installed, the minimum installed weight per square foot shall conform with the insulation manufacturer's installed design weight per square foot at the manufacturer's labeled R -value. 3. Wall Insulation. The opaque portions of frame walls separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a. or b. below: a. Framed walls shall be insulated between framing members with insulation having an installed thermal resistance of R-13 or greater. Framed foundation walls of heated basements or heated crawl spaces shall be insulated above the outside ground line with insulation having an installed thermal resistance of at least R-13. ALTERNATIVE to Section 150 (c) 1: Insulation which is not penetrated by framing m embers may meet an R -value equivalent to installing R-13 insulation between framing members and accounting for the thermal effects of framing members. b. The weighted average U -value of walls shall not exceed the U -value that would result from installing R-13 insulation between framing members in the entire ceiling and accounting for the effects of framing members. (.088 Max.) 4. Raised Floor Insulation. Raised floors separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a. or b. below: a. Floors shall be insulated between framing members with insulation having an installed thermal resistance of R-13 or greater. b. The weighted average U -value of floor assemblies shall not exceed the U -value that would result from installing R-13 insulation between framing members and accounting for the effects of framing members. (.064 Max.) Sec. 150 (a) -(d) (V) Systems, equipment, and building components listed below may be installed only if: 1. The manufacturer has certified that the system, equipment, or building component complies with the applicable manufacture provisions of Sections 111 through 119; and 2. The system, equipment, or building component complies with the applicable installation provisions of Sections 111 through 119. Covered are: a. Appliances regulated by the Appliance Efficiency Regulations (Sec. 111). b. Space conditioning equipment (Sec. 112). c. Pool and spa heating systems and equipment (Sec. 114). d. Gas appliances (Sec. 115). e. Insulation (sec. 118). Sec. 110 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 .4.4******* Project A ress........ Catrus Course La Quinta, California *v6.01* Documentation Author... Rick Maurer ******* Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 C1' t Z 15 ima a one.... ..... Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories..... ... Floor Construction Type.... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... 4835 sf Single Family Detached New Front Facing 225 deg (SW) 1 1 Slab On Grade 21.8 % of floor area 0.57 Btu/hr-sf-F 0.51 12 ft BUILDING SHELL INSULATION Component Frame Building Permit Plan Check Date Field Check/ Date ima a one.... ..... Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories..... ... Floor Construction Type.... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... 4835 sf Single Family Detached New Front Facing 225 deg (SW) 1 1 Slab On Grade 21.8 % of floor area 0.57 Btu/hr-sf-F 0.51 12 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -factor Location/Comments Wall Wood R-19 R-n/a R-19 0.065 Attic KneeWall Front Wall, Gar. Wall Left Wall, Back Wall Right Wall Roof Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door Left Door S1abEdge None R-0 R-0 F2=0.760 To Outside S1abEdge None R-0 R-0 F2=0.510 To Garage FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins Door Front (SW) 80.0 0.550 0.650 Standard Standard Yes Window Front (SW) 28.0 0.550 0.450 Standard Standard Yes Door Front (SW) 48.0 0.990 0.740 Standard Standard Yes Window Front (SW) 10.5 0.550 0.450 Standard Standard Yes Window Front (SW) 27.5 0.550 0.450 Standard Standard Yes Window Front (SW) 25.0 0.550 0.450 Standard Standard Yes Window Front (SW) 10.5 0.550 0.450 Standard Standard Yes Window Front (SW) 8.0 0.550 0.450 Standard Standard Yes Window Front (SW) 12.0 0.550 0.450 Standard Standard Yes Window Left (NW) 30.0 0.550 0.450 Standard Standard Yes Door Left (NW) 48.0 0.550 0.650 Standard Standard Yes CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins Window Left (NW) 30.0 0.550 0.450 Standard Standard Yes Window Left (NW) 10.0 0.550 0.450 Standard Standard Yes Window Left (NW) 6.0 0.550 0.450 Standard Standard Yes Door Left (NW) 64.0 0.550 0.450 Standard Standard Yes Window Left (NW) 6.0 0.550 0.450 Standard Standard Yes Door Left (NW) 24.0 0.550 0.650 Standard Standard Yes Window Left (NW) 18.0 0.550 0.450 Standard Standard Yes Window Back (NE) 12.0 0.550 0.450 Standard Standard Yes Window Back (NE) 24.0 0.550 0.450 Standard Standard Yes Door Back (NE) 180.0 0.550 0.450 Standard Standard Yes Window Back (NE) 14.0 0.550 0.450 Standard Standard Yes Window Back (NE) 48.0 0.550 0.450 Standard Standard Yes Door Back (NE) 20.0 0.550 0.650 Standard Standard Yes Window Back (NE) 48.0 0.550 0.450 Standard Standard Yes Window Back (NE) 8.0 0.550 0.450 Standard Standard Yes Door Right (SE) 100.0 0.550 0.450 Standard Standard Yes Door Right (SE) 48.0 0.550 0.650 Standard Standard Yes Window Right (SE) 30.0 0.550 0.450 Standard Standard Yes Window Right (SE) 4.5 0.550 0.450 Standard Standard Yes Window Right (SE) 6.0 0.550 0.450 Standard Standard Yes Window Right (SE) 6.0 0.550 0.450 Standard Standard Yes Window Right (SE) 18.0 0.550 0.450 Standard Standard Yes THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 1791 3.5 Exp.Conc.Slab-See Note S1abOnGrade No 3044 3.5 Covered Concrete Slab InteriorHorz Yes 171 1.0 Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 462 1.0 Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Refrigerant Tested ACOA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R -value Leakage D Type Furnace 0.800 AFUE n/a Attic R-6 Yes No Setback ACSplitTXV 12.00 SEER Yes Attic R-6 Yes No Setback CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 DUCT TESTING DETAILS Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) Furnace / ACSplitTXV 6% / 203.1 n/a WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value WH1 Storage Gas Recirc/TimeTemp 1 .56 50 R-12 WH2 S.torage Gas Recirc/TimeTemp 1 .51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a High Mass Design. This building incorporates non-standard Duct R -value. This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). Mandatory Measures require a R-12 or greater external blanket.on Gas Storage Water Heaters with Energy Factors less than 0.58. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF -1R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 HERS REQUIRED VERIFICATION for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS 1) Each water heater specified will require an external insulation blanket of R-12 or greater. 2) This house requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) Each water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows and sliding glass doors will have wood frames with metal cladding and an NFRC U -factor of .55 or less and a SHGC of .45 or less with high performance Low -E glass. 5) All hinged french doors will have wood or fiberglass frames with dual pane glass and default values. 6) The entry doors will have wood frames with single pane glass and default values. 7) The following rooms will have hard surface flooring: Entry/Halls/Powder Kitchen/Dining Wet Bar/Pantry Great Room Service Library CERTIFICATE OF COMPLIANCE: RESIDENTIAL. Page 5 CF -1R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DES3GRER or OWNER Name.... Company. Sunista velopment Address. 51- 30 Avenida Bermudas#2 La Quinta, CA 92253 Phone... (760) 771-4722 License. Signed.. date ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. date DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24, Inc. Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed.. 7- 3 12,,G o (da:teYr COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 ******* Project Address........ Citrus Course La Quinta, California *v6.01* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24, Inc. 7544 E Saddlehill'Trail Plan Check Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone. .. ..... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 MICROPAS6 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.94 3.90 0.04 Space Cooling.......... 36.15 34.62 1.53 Water Heating.......... 5.89 7.41 -1.52 Total 45.98 45.93 0.05 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... 4835 sf Single Family Detached New Front Facing 225 deg (SW) 1 1 FullYear Slab On Grade 1 58020 cf 4835 sf 21.8 % of floor area 0.57 Btu/hr-sf-F 0.51 12 ft BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Zone Type (sf) (cf) Units itioned Vent Vent Air Thermostat Height Area Leakage Type (ft) (sf) Credit HOUSE Residence 4835 58020 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY %Project Title.......... Sun Vista Devlp.-Lot #15 Page 2 C -2R Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 OPAQUE SURFACES HOUSE Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments HOUSE (SW) 28.0.0.550 0.450 225 90 3 Door 1 Wall 290 0.065 19 225 90 Yes None Attic KneeWall 2 Wall 652 0.065 19 225 90 Yes None Front Wall 3 Wall 289 0.065 19 225 90 No None Gar. Wall 4 Wall 847 0.065 19 315 90 Yes None Left Wall 5 Wall 40 0.065 19 315 90 No None Gar. Wall 6 Wall 850 0.065 19 45 90 Yes None Back Wall 7 Wall 908 0.065 19 135 90 Yes None Right Wall 8 Roof 4835 0.025 38 n/a 0 Yes None Vented Attic 9 Door 21 0.330 0 225 90 No None Garage Door 10 Door 21 0.330 0 315 90 Yes None Left Door 6.0.0.550 0.450 315 90 PERIMETER LOSSES Left (NW) 64.0.0.550 0.450 Length F2 Insul Solar Left (NW) 6.0.0.550 Surface 315 (ft) Factor 17 R-val Gains Location/Comments 24.0.0.550 HOUSE 315 90 18 Window Left (NW) 18.0 0.550 0.450 11 S1abEdge 429 0.760 R-0 No To Outside 12.0 0.550 0.450 12 S1abEdge 35 0.510 R-0 No To Garage 24.0*0.550 0.450 45 90 21 FENESTRATION SURFACES (NE) 180.0.0.550 0.450 45 Area U- Window Act I Exterior Shade Interior Shade Orientation 0.450 (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC HOUSE 1 Door Front (SW) 80.0.0.550 0.650 225 90 2 Window Front (SW) 28.0.0.550 0.450 225 90 3 Door Front (SW) 48.0.0.990 0.740 225 90 4 Window Front (SW) 10.5.0.550 0.450 225 90 5 Window Front (SW) 27.5.0.550 0.450 225 90 6 Window Front (SW) 25.0•"0.550 0.450 225 90 7 Window Front (SW) 10.5.0.550 0.450 225 90 8 Window Front (SW) 8.0.0.550 0.450 225 90 9 Window Front (SW) 12.0.0.550 0.450 225 90 10 Window Left (NW) 30.0.0.550 0.450 315 90 11 Door Left (NW) 48.0.0.550 0.650 315 90 12 Window Left (NW) 30.0.0.550 0.450 315 90 13 Window Left (NW) 10.0.0.550 0.450 315 90 14 Window Left (NW) 6.0.0.550 0.450 315 90 15 Door Left (NW) 64.0.0.550 0.450 315 90 16 Window Left (NW) 6.0.0.550 0.450 315 90 17 Door Left (NW) 24.0.0.550 0.650 315 90 18 Window Left (NW) 18.0 0.550 0.450 315 90 19 Window Back (NE) 12.0 0.550 0.450 45 90 20 Window Back ('NE) 24.0*0.550 0.450 45 90 21 Door Back (NE) 180.0.0.550 0.450 45 90 22 Window Back (NE) 14.0-0.550 0.450 45 90 23 Window Back (NE) 48.0.0.550 0.450 45 90 24 Door Back (NE) 20.0.0.550 0.650 45 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 Orientation FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC 25 Window Back (NE) 48.0.0.550 0.450 45 90 26 Window Back (NE) 8.0'0.550 0.450 45 90 27 Door Right .(SE) 100.0 0.550 0.450 135 90 28 Door Right (SE) 48.0.0.550 0.650 135 90 29 Window Right (SE) 30.0.0.550 0.450 135 90 30 Window Right (SE) 4.5 0.550 0.450 135 90 31 Window Right (SE) 6.0.0.550 0.450 135 90 32 Window Right (SE) 6.0.0.550 0.450 135 90 33 Window Right (SE) 18.0 0.550 0.450 135 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 OVERHANGS AND SIDE FINS Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Door 80.0 n/a 8.0 3.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 28.0 n/a 7.0 8.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 48.0 n/a 8.0 3.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 10.5 n/a 2.0 3.0 0.8 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 27.5 n/a 5.5 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 25.0 n/a 5.0 1.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 10.5 n/a 2.0 1.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 8.0 n/a 4.0 2:0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 12.0 n/a 3.0 2.0 2.3 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 30.0 n/a 6.0 17. 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 48.0 n/a 8.0 17. 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 30.0 n/a 6.0 2.0 3.8 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 10.0 n/a 2.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 6.0 n/a 3.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 15 Door 64.0 n/a 8.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a- n/a 16 Window 6.0 n/a 3.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 17 Door 24.0 n/a 8.0 3.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 18.0 n/a 3.0 2.0 2.3 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 12.0 n/a 3.0 2.0 2.3 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 24.0 n/a 6.0 26. 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Door 180.0 n/a 10. 16.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 14.0 n/a 2.0 3.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 48.0 n/a 6.0 3.0 3.8 n/a n/a n/a n/a n/a n/a n/a n/a 24 Door 20.0 n/a 8.0 3.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 48.0 n/a '6.0 3.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 8.0 n/a 4.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 27 Door 100.0 n/a 10. 26. 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 28 Door 48.0 n/a 8.0 35. 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 30.0 n/a 6.0 2.0 10.5 n/a n/a n/a n/a n/a n/a n/a n/a 30 Window 4.5 n/a 3,.0 2.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 31 Window 6.0 n/a 3.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 32 Window 6.0 n/a 3.0 2.0 1.8 n/a n/a n/a n/a n/a n/a n/a n/a 33 Window 18.0 n/a 3.0 2.0 2.3 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments HOUSE 1 S1abOnGrade 1791 3.5 28.0 0.98 4.60 R-0.0 Exp.Conc.Slab-See Note 2 S1abOnGrade 3044 3.5 28.0 0.98 1.80 R-2.0 Covered Concrete Slab 3 InteriorHorz 171 1.0 24.0 0.67 1.70 R-0.0 Tile-Kit.Ctr,Fp,Tub/Sh 4 InteriorVert 462 1.0 24.0 0.67 1.70 R-0.0 Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency Airflow Location R -value Leakage D Eff HOUSE Furnace 0.800 AFUE n/a Attic R-6 Yes No 0.845 ACSplitTXV 12.00 SEER Yes Attic R-6 Yes No 0.736 DUCT TESTING DETAILS" Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) HOUSE Furnace / ACSplitTXV 6% / 203.1 n/a WATER HEATING SYSTEMS Tank Type WH1 Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Recirc/TimeTemp 1 .56 50 R-12 WH2 2 Storage Gas Recirc/TimeTemp 1 .51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a High Mass Design. This building incorporates non-standard Duct R -value. This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s) . COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 SPECIAL FEATURES AND MODELING ASSUMPTIONS Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. This building incorporates non-standard Water Heating System HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS 1) Each water heater specified will require an external insulation blanket of R-12 or greater. 2) This house requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) Each water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows and sliding glass doors will have wood frames with metal cladding and an NFRC U -factor of .55 or less and a SHGC of .45 or less with high performance Low -E glass. 5) All hinged french doors will have wood or fiberglass frames with dual pane glass and default values. 6) The entry doors will have wood frames with single pane glass and default values. 7) The following rooms will have hard surface flooring: Entry/Halls/Powder Kitchen/Dining Wet Bar/Pantry Great Room Service Library COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -FORM C -2R User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 REMARKS HVAC SIZING Page 1 HVAC Project Title.......... Sun Vista Devlp.-Lot #15 Date..03/26/02 20:50:59 ******* Project Address........ Citrus Course La Quinta, California *v6.01* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24, Inc. 7544 E Saddlehill Trail Plan Check Date Orange, CA 92869 714-771-1507 Field Check Date Climate Zone. .. ...... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-SUNVST22 Wth-CTZ15S92 Program -HVAC SIZING User#-MP0357 User -Rick Maurer Title 24, Inc Run -Citrus Course - Lot #15 GENERAL INFORMATION Floor Area ................. Volume. ..... ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. ...... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 4835 sf 58020 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts. ..... ................... Sensible Load .................... Latent Load ...................... 225 deg (SW) Heating Cooling (Btuh) (Btuh) . 27761 14828 22789 20390 n/a 27272 41432 27235 n/a 10800 9198 10053 101181 110578 n/a 33173 Minimum Total Load 101181 143752 x/.3 =13/5 -35 - Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. MICAOPASS -■ Table 2.2. Standard U -values of Wood Frame Roofs/Cedings and ►falls! Roof/Ceiling Framing Ref==C Insulation Spacing Name U -Value R-03 16" o.c. R-0 2X6.16 0.299 R-03 24' o.c. R -0.2X4.24 0.306 R-1 l3 l6' o.c. R.I I- X6.16 0.077 R- t t3 24' o.c. R. 11.2X4 0.076 R-133 16" o.c. R. 13.2X6.16 0.069 R-133 24' O.C. PL 13.2X4.24 0.068 R49 9 t 6" o.c. R.19 2X8.16 0.051 R-19 24' o.c. R -19.2X4.24 0.047 R-22 16" o.c. R.221.2X I0.16 0.044 R-22 24' o.c. R.22_'X424 0.041 R-30 16" o.c. R 30.2X10.16 - 0.036 R-30 16" O.C. R.30.2X12.16 0.035 R-30 24" o.c. R.30.2X424 0.031 R-38 16" o.c. R.39.2X12.16 0.029 R-38 16" o.c. R.38.2X14.16 0.028 R-38 24" o.c. R38.2X14?4 0.025 R-49 16" o.c. R 49.2X-1.16 0.019 R-49 24" o.c. R:491X4.24 0.019 Nall Insulation R-03 16' o.c. W.0.2X4.16 0.386 R-03 24" o.c. W.0.2,X4.24 0.393 R-73 16" O.C. W.7.2X4.16 0.130 R-73 24" O.C. W.7.2X4.24 0.127 R-113 16" o.c. W.I 12X4.16 0.098 R-113 24" o.c. ANV.1I?Y-1.24 0.094 R-13 16- o.c. W. I 3.2X,*. 16 0.088 R-13 24" O.C. W.13?\4.24 0.055 R-15 16" o.c. W.15 2X4.16 0.081 R-15 24" o.c. W.15 2X-1.224 0.077 R-19 16" o.c. W.192X6.16 0.065 R-19 24" o.c. W. 19.2X6.24' 0.063 R-21 16" o.c. N 212X6.16 0.059 R-21 24" o.c. W.21 2X6.24 0.056 R-25 16" o.c. W_5..X6-16 0.046 R-29 16', o.c. 1'.292X4.16 0.035 Solidcore wood D.0SC%V 0.330 door (no insulation) L Based on ASHRAE Parallel heat Flow Calculation. ASHRAE Handbook of Fundamentals. 2. These Reference Names are taken from Appendix Hof the Residential Manual. 3. :Does not meet the minimum level required as a mandatory measure (see Pan 2-2 of the Residenrivl dfanual). 4. Roof/ceiling assemblies whose reference names list 2x4 framing include an attics ace. 2-34COMPUANCE 0611&99 0 1999 by Enercomp, Inc Chapter Z INPUT REFERENCE Table 2-4. Standard U -values of Wood Foam Panel Roofs/Ceilings and tv'alls, Roof/Ceiling Framing Reference' - Insulation Spacing Name U -Value R- I 43 48" o.c. RP.14.2X4.418 0.064 R-22 48" o.c. RP.�?.2X6.48 0.044 R-28 48" O.C. RP.28.2X8.48 0.035 R-36 48" O.C. iP.36.2XI0.48 0.028 Nall Insulation R-14 =8" O.C. NVP.14.2X4.48 0.071 R-22 <8" O.C. N%`P 22.2X6.48 0.049 1. Based on ASHRAE Parallel heat Flow Calculation. ASHRAE Handbook of Fundamentals. 2. The names given to the standard assemblies used to calculate these U -values in Appendix H of the Residential Manual. Does not meet the minimum level required as a mandatory measure (see Part 2.2 of the Residential Manual). © 1999 by Enercomp, It= Table 2-3. Standard U -values of hood Frame Raised Floorst Floor Reference,- eference=Insulation Insulation Condition Name U -Value R-03 No crawispace FXD-2X6.16 0.239 R-03 Crawlspace FCO -2X6.16 0.097 R-113 No crauispace FXI 1.2X6.16 0.071 R-113 Crawlspace FCI (?X6.16 0.049 R-13 No crawlspace FXI3.2X6.16 0.064 R-13 Crawlspace FCI3?X6.16 0.046 R-19 No crawlspace FX19.2X8.16 0.048 R-19 Crawlspace FC 19.2X8.16 0.037 R-21 No crawlspace FX21.2X8.16 0.045 R-21 Crauispace FC21 2X8.16 0.035 R-30 No crawlspace FX30.2X10.16 0.034 R-30 Crawlspace FC30?X 10. 16 0.028 1. Based on ASHRAE Parallel heat Flow Calculation. ASHRAE Handbook of Fundamentals. 2. The Names given to the standard assemblies used to calculate these U -values in Appendix H of the Residential Manual. 3. Does not meet the minimum level required as a mandatory measure (see Part 2.2 of the Residential ,ifanual). Table 2-4. Standard U -values of Wood Foam Panel Roofs/Ceilings and tv'alls, Roof/Ceiling Framing Reference' - Insulation Spacing Name U -Value R- I 43 48" o.c. RP.14.2X4.418 0.064 R-22 48" o.c. RP.�?.2X6.48 0.044 R-28 48" O.C. RP.28.2X8.48 0.035 R-36 48" O.C. iP.36.2XI0.48 0.028 Nall Insulation R-14 =8" O.C. NVP.14.2X4.48 0.071 R-22 <8" O.C. N%`P 22.2X6.48 0.049 1. Based on ASHRAE Parallel heat Flow Calculation. ASHRAE Handbook of Fundamentals. 2. The names given to the standard assemblies used to calculate these U -values in Appendix H of the Residential Manual. Does not meet the minimum level required as a mandatory measure (see Part 2.2 of the Residential Manual). © 1999 by Enercomp, It= 06/10/99 COMPLIANCE 2 m 3 5 Table 2-5. Slab Edge Neat Loss Rate (F2 Factor) Insulation It -Value Insulation Depth (in.) R-0 / R-3 R•5 R-7 0 0.76 0.76 0.76 0.76 8 0.76 0.66 0.64 0.64 12 0.76 0.62 0.58 0.56 18 0.76 0-59 0.54 0.514 24 0.76 0.57 0.53 0.50 06/10/99 COMPLIANCE 2 m 3 5 MICROPASS 4) 5) 6) Table 2-6. Default Fenestration Product U -Values (this table to be used by manufacturer's to establish a U-Valuerating without performance testing) Single Pane Double Pane Frame Type Product Type U -value U -value' - Metal Operable 1.28 0.87 Metal Fixed 1.19 0.72 Metal Greenhouse/Garden window 2.26 1.40 !Metal Doors 1_35 0.85 Metal Skylight 1.72 0.94 Metal. Thermal Break Operable 0.71 Metal. Thermal Break Fixed 0.60 Metal, Thermal Break Greenhouse/Garden window 1.12 Metal, Thermal Break Doors 0.64 Acetal, Thermal Break Skylight O.SO Kon -Metal Operable 0.990.60 Non -Acetal Fixed 1.04 0.57 Kon -Metal Doors 0.99 0.55 Kon -Acetal Greenhouse/Garden windows 1.93 1.06 Non -Metal Skylight 1.47 0.68 I. :Metal includes any field -fabricated product with metal cladding. Kon -metal framed manufactured fenestration products with metal cladding must add 0.04 to the listed U - value. Kon -Acetal frame types can include metal fasteners, hardw-are, and door thresholds. Thermal break product design characteristics are: a. The material used as the hermal break must have a thermal conductivity of not more than 3.6 Btu-inch/hr/f .VF, b The thermal break must produce a Lap of not less than 0.210-. and c All metal members of the fenestration product exposed to interior and exterior air must incorporate a thermal break meeting the criteria in (a) and (b) above. In addition, the fenestration product must be clearly labeled by the manufacturer that it qualifies as a thermally broken product in accordance with this standard. 2. For all dual glued fenestration products, adjust the listed U -values as follows: a. Subtract 0.05 for spacers of 7/16' or eider. b. Subtract 0.05 for products certified by the manufacturer as low -E glazing. C. Add 0.05 for products with dividers between panes if spacer is less than 7/16' wide. d. Add 0.05 to any product with true divided lite (dividers through the panes). T�;' Kate. - C-raluesfoperator types: T7te default U -Value of a fenestration product changes based on rite operator type. For example, a sliding -i) -pe windon, will have a different U -Value than a fired Vvindon- that is otherwise identical (see Table 2-6) As the U -Value, orientation, tilt, shading device, solar (rear gain coefficient, overhang and fut configuration are all input iariables it is recommended that gado Window of a building be entered inro MICROPAS individual1r. All windows and sliding glass doors will have wood frames with metal cladding and an NFRC U -factor of .55 or less and a 5HGC of .45 or less with high performance Low -E glass. All hinged french doors will have wood or fiberglass frames with dual pane glass and default values. The entry doors will have wood frames with single pane glass and default values. A Chapter 2: INPUT REFERENCE G4e More - labeling: As of lanuary 1. 1991. all fenestrarion products used for new. retrofit or remodel construction. must display a label stating the ►rindow lines performance.Beginning in July 1999. the only e-reeprion to labeling is for field fabricated fenestration products. These are products constructed at the building site from materials not cut or formes frith rile intention of making a fenestration product. All other products must be labeled with a CFC Default or 'FRC -rated U -value and solar hear gain coefficient (see Table 2.6 and Table 2-7). Table 2-7. Default Solar Heat Gain Coefficient Total Window SHGC Sincle Double Frame Type Product Glazing Pane Pane Acetal Operable Uncoated 0.80 0.70 ;,fetal Fixed Uncoated 0.83 0.73 Acetal Operable Tinted 0.67 0.59 Metal Fixed Tinted 0.68. 0.60 Acetal. Thermal Break Operable Uncoated 0.72 0.63 Metal. Thermal Break Fixed Uncoated 0.78 0.69 :Metal. Thermal Break Operable Tinted 0.60 0.53 Aictal. Thermal Break Fixed Tinted 0.650.57 Non -Acetal Operable Uncoated 0.74 0.65 Kon -?Metal Fixed Uncoated 0.76 0.67 Kon -Metal Operable Tinted 0.60 0.53 Kon-Atctal Fixed Tinted 0.63 0.55 SHGC = Solar Heat Gain Coefficient .Vote - Low -e Glass Default SHGC: Although low -e glass is a coaxed product. for purposes of compliance, if you do not have an NFRC value for the SHGC, use the uncoated vahnes from Table 2-7. Low -e glass is nor c tinted product. Glazing Area The area for glazing or fenestration products is calculated from the nominal (e.g.. 503°) or touch opening dimensions. Doors: Any door having glass must be entered in MICROPAS as dazing area. For any door with an NFRC rating (doors with more than 50 percent of their surface area made up of glass). the entire area of the door must be entered in MICROPAS as glazing area. since the product rating is for the entire door. For doors with 50 percent or less of their surface area made up of glass enter either the entire door area as glazing or the actual area of glass plus a two inch frame extending on all sides (the remaining door arca is modeled as an OPAQUE SURFACE. The U -value and solar heat gain coefficient of the door is taken from Table 2-6 and Table 2-7 or manufacturer data. Greenhouse (garden) Windows: Greenhouse window glazing area is calculated usine the rough opening for the unit (see Figure 2-23). The typically higher U -value of greenhouse windows accounts for additional heat loss from the projecting top, sides and bottom of the unit. Glazing Orientation Orientation (azimuth) for fenestration products is always relative to the designated 'front - orientation (referred to as the Plan Azimuth) (see Table 2-1). The designations 'Right' and Left' are from the perspecti%r of someone outside. facing the front of the house. Also see Figure 2-18 (under opaque surfaces) for a sample diagram. 4) All windows and sliding glass doors will have wood frames with metal cladding and an NFRC U -factor of .55 or less and a SHGC of .45 or less with high performance Low -E glass. 5) All hinged french doors will have wood or fiberglass frames with dual pane glass and default values. 6) The entry doors will have wood frames with single pane glass and default values. Chapter 2: INPUT REFERENCE C:�_ Aote — Interior and Erterfor Shading T)pesSo&r Heat Gain Coefficients. 8�y choosing either Trandard' or 'None' as the shading device r)pe. the CEC standard assumption for interior and exterior shading is modeled kr AfICROPAS (drapes and bug screens on glainng other than sk lights. and no interior or exterior shading on skylights). Table 2-8. Solar Near Gain Coefficients for Interior Shading Devices Standard: Drapery 0.681 Blinds: Venetian Blinds. Vertical Blinds or NtiniBlinds 0.47 Roller Shade Opaque Roller Shades 0.472 Kone (for Skylights only) 1.00 Kone (for vertical glazing surfaces) 0.68 1. 0.65 is the default value used when there is no interior shading device installed on vertical fenestration products. 2. On January L 2002. Opaque Roller Shades must be modeled with a 0.68 SHGC. Table 2.9. Solar Shadinr Device2 Gain Coefficients for Exterior Shading Standard (Bug Screens) Woxen Exterior Shades wens (53x l6finch weave) Louvered Shadescreens wAouvers as wide as openings Low Sun Angle (LSA) Louvered Shadescreens Roll down (awnings. blinds, or slats) Kone (for skylights only) Kone (for vertical glazing surfaces) Substantially Shaded/Building Shade wf Sintle Pane Clear GlasS3 0.76 0.30 0.27 0.13 0.13 1.00 0.76 0.20 1. Exterior operable awnings (canvas, plastic or metal) except those that roll .vertically down and cover the entire window, should be treated as overhangs. I2. Standard bug screens are assumed for all vertical glaring unless replaced by other exterior shade screens. The SHGC for bug screens is an area -weighted value that assumes that the screens are only on operable windows. The SHGC of exterior shade screens that are applied to some of the window areas is area•weighted with the SHGC of bug screens for the remainder of the glazing. 3. Reference glass for SHGCs is IB inch double strength sheet (DSS) glass. from the Residential ,Manual. 0 1999 by Enercomp, Ina 06110/99 COMPLIANCE 2-41 MAR -21-2002 09:04 AM ESSI SHAHANDEH 7603405597 P.03 u J O GLAZING AREAll ('y✓Nexx o VVIV e^ n i t -J , 111 � . 0#4 pe, I- f v P�"r - yvP.�r, � v -e.s T. • W -S -Mr --n LQ T . ) S q�35 Sa.Fr. Al p•tL 1/ Y to = 2 `f F , 4Af./&", I8x/'0 =)g0 %1649 p)N. &X L- ' 11/ 1--li'F.12. n,N. X x (. -V8 Br!•j ZbXd,' ?gyp P,0, X31%3 XXL Plo-r7 4 L x y k ovvl`&.,L t ?� 3 = ) 8' (3) ►s^' F. S KYLIGI-�'t"S 0 12 Irv, / 0 X/ O = 10 0 S d.0 y 2T. n*vl , Lb x to Q-) 2,'o X -L = 10 (�-1 Z?3 =b Plo-r7 4 a - -Y8 =ey 3,1647 Z r = b 3 x 9 =Ly F-. V, ovvl`&.,L t ?� 3 = ) 8' (3) ►s^' F. S KYLIGI-�'t"S 0 12 Irv, / 0 X/ O = 10 0 S d.0 y 2T. n*vl , 149 k tT = y Fr N I F . rO . 0 vt//v PJ't 2,10 b= -10 (-- ) Plo-r7 4 tax 3 to x t- 710j C e T L- ,v 3 S l��(,✓n, 2 3 = �D o wnen i x 3 8 (S 61 O !�O) w TOTAL_ LA %WG = Z lo tc X P = 4 r lv! Fn f. nig, i ErvT- , to x t- I O. S ►+�' F. R. (�ve.>r 5X5 = 25 yve.!�r•. .SQL - /V.Sµ'F.a, G% - Os. I.--fy : k 61 O !�O) w TOTAL_ LA %WG = EQUIPMENT (.09, SQUAL-) CU 5,TO M.. HVME couaL-.-E7 SWMY, SEQV, lliTCAM,; Irv. 2.+ 3, Ppa. p 2- .t mAi-%- arcZT4 m UPFLOW GqA .FAU. Sbmvowi(o sBeAv I HIC) PN.Fl_VW..CjM7...FAU AF.UF_ (MIDI) 0t7°lo f30% IBTU OVTPUT 71j000 (39,000 CFM . .1-140. VF_V-T -GOO o¢.a ..Cvo4_.CO_l TXV � Goovew51.141, UmT eEE9, (MIVA To Nev lailu 1 0 9.5 0 5.aw5., ap. I I5° .AMERICAN- WATER HF_A-fEt2,S C^.fZV_)EfZ CO-. HEATIt-461 4 A/c, st 605440W C,125.&WOUG CV54bD(oD CP5"03D E4 4 y S47. 'Y 0 Li 5 L4 Z y�,Sno 58,000 H-11500 --l- 23moo 3.1 ) S.)(,o ----.-Ato, M0 HVAC Ducr Tss-r . ..... ..... .. . I.W...v"C0NViTlc2N.F_0. SvPA_C_S6_ CLeFr - sios) dim) WA-Tmz ... VA F -A -ma I 75 lam.uH 7U°%o AD ...... ... — HVAC Ducr Tss-r . ..... ..... .. . I.W...v"C0NViTlc2N.F_0. SvPA_C_S6_ HEATING & COOUNG Product 58PAV DataHigh-Efficiency _ Induced -Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80% Annual Fuel Utilization Efficiency (AFUE) Ps furnace for the budget conscious consumer and builder. The 58PAV offers the same high quality you demand and receive from Carrier. The cabinet is constructed from a specially selected galvanized steel. There is also double protection for the cabinet. First, a galvanized steel substrate provides resistance to rusting. Then the cabinet is constructed of prepainted steel — the same high- quality finish found on refrigerators and dishwashers. The 58PAV offers a hot surface ignition system which provides a superior and more reliable ignition system than older spark relight systems. The heat exchangers are constructed of aluminized steel and covered by a 20 -year Limited Warranty. They are Carrier's patented Super -S heat exchangers that improve heat transfer and enable downsizing of this furnace to only 40 -in. tall. To improve the sound level, we have incorporated a soft mount inducer assembly and a slow opening gas valve. The control board is the brain of this induced -combustion gas furnace. It offers a unique self -test feature that checks all the major functions of the furnace within 1 minute. The control board also features a 3 -amp fuse that protects the transformer and control board. Another feature on the control board is a LED status indicator light to ensure top furnace performance. Iopyright 1996 Carrier Corporation Form No. 58PAV-6P[) Carrier accessories* C Iu �RrFw FURNACE A93D67 RETURN -AIR PLENUM Custom made retum-air plenum can be mounted on either side of the furnace. Includes washable fitters. A 25 in. B 16 in. C 39-7/8 in. „3068 SIDE FILTER RACK Custom made fiber rack for easy connection when a return plenum already exists. Provides easy access for cleaning titter. A 23-1/8 in. B 2-3/8 in. C 14-1/2 in. MODEL 31KAX ELECTRONIC AIR CLEANER Cleans the air of smoke, din, and many pollens commonly found. Saves decorating and cleaning expenses. MODEL 49FH HUMIDIFIER By adding moisture to wimer-dry air, a Carrier humidifier can often improve the comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. "WNITSIZE. ::.1)45.08=2t'12`�t 070088 2 090-14`S�7'6' iJ6�e`30Y� .1135-161?i�0�:c,_ , 455-20 t ELECTRONIC AIR CLEANER Model 31KAX HUMIDIFIER Model 49FH THERMOSTAT See Master Price Pages RETURN -AIR PLENUM (With Washable Filters) KGARP0101ALL SIDE FILTER RACK (With Washable Filter) KGAFRO101ALL TWINNING KIT KGATW0401HSlt GAS CONVERSION KIT Natural -To -Propane KGANP2001ALL Propane -To -Natural KGAPN1601ALL Factory -authorized and field installed. Gas conversion kits are A.G.A. recognized. t 16 and 20 sizes only. Physical data - _ .t ,r-:i'S, •'.`t''� �'�''a�.'. -'T :-Y.SQQS.G'_ ..Y-%. 12 - +t T':[3"„c.:-`if"i���_. >:�• ,:14�-:t 6�;,i�.12'.: ;:;i3o.:. {T-,�^•.AFMtj'_.3.f'•' -: 16. a$S iie, OUTPUT CAPACITY (BTUH)t Nonweatherized ICS 35,000 35,000 53,000 53,000 71,000 71,000 89,000 89,000 89,000 1107,OW 107,000 124,000 INPUT BTUW 44,000 44,000 66,000 66,000 88,000 88,000 110,000 110,000 110,000 132,000 132,000 154,000 SHIPPING WEIGHT (Lb) 114 116 124 126 140 144 150 156 172 168 182 192 CERTIFIED TEMP RISE RANGE (°F) 25.55 15-45 40.70 30.60 40-70 30-0 55.85 45-75 25-55 5080 40.70 50-80 CERTIFIED EXT STATIC PRESSURE Heating Cooling 0.10 0.5 0.10 0.5 0.12 0.5 0.12 0.5 0.15 0.5 0.15 020 020 0.5 0.5 0.5 020 0.5 020 0.5 020 0.5 020 OS AIRFLOW CFM# Heating Cooling 855 930 1070 1270 830 950 1175 1300 1150 1335 1445 1175 1415 1740 1210 1575 1720 2210 1645 1620 1975 1980 1695 1905 UMIT CONTROL SPST HEATING BLOWER CONTROL Solid -State Time Operation BURNERS (Monoport) 2 1 2 1 3 1 3 4 1 4 1 5 1 5 5 6 6 7 GAS CONNECTION SIZE 1/2 -in. NPT GAS VALVE (Redundant) Manufacturer White -Rodgers Minimum Inlet Pressure Qn. wc) 4.5 (Natural Gas) Maximum Inlet Pressure (in. wc) 13.6 (Natural Gas) IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4. In Canada, derate the unit 10% for elevations 2000 ft to 4500 ft above sea level. t Capacity in accordance with U.S. Government DOE test procedures. $ Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only, of the furnace be used for return air. A filter is required for each return -air supply. ICS—Isolated Combustion System El Dimensions CLEARANCES (In.) UNIT SIZE 045 AND 070 090-155 Sides -- Single -Wall Vent 1 0 Type B-1, Double -Wall Vent 0 0 Back 0 0 Top of Plenum 1 1 Vent Connector — Single -Wall Vent 6 6 Type B-1, Double -Wall Vent 1 1 Front* — Single -Wall Vent 6 6 Type B-1, Double -Wall Vent 3 3 Service 30 30 'The 3 -in. front clearance is needed for combustion -air and ventilation -air entry. Trp r o ta ------------- 4 JI L �L W I t: •y1r��E AIRFLOW —23 A xHr D — FLUE COLLAR 2 nr gar I II Te•ea ou M NDLE11ft POWER ENTRY S W ��— SW POWER ENTRY ,► K Du rH 1 VIM. MA UNIT SIZE. ACCESSORY I S r i� S `a+i AM. GAS ENTRY 045-12: 1 if" DN IDLE 24t 01A ACCESSORY 070-12 GAS ENTRY 090.14 I .090-16 '?eL OU HOLE 2 W 111-12 ' K DIA THERMOSTAT YIK1E FMRY - .11111-116. THERMOSTAT vnFIE ENTRY '111-20 :. 24-1/2 22-7/8 22 4 .3,135-16 v v %-1.35-20 •: " v v SIM INLET 'Refer to the furnace Installation Instructions for proper venting procedures. SDE INLET I Trp r o ta ------------- ^� 1��2a �1r�--T--{ JI L �L W I t: •y1r��E A1R tN(ET II TW~ DMS SDE RENRN DUCT LOCATION NOTES: 1. T— a06aOna1 A -b. di. M OA Mare baebd N to top pate 2 MMYIMYn remneir Werirq al lurrlec9: a. F 8000 a t IVia 12ii eerlylJ4 FM 20L ro ra F.00 D. 12CFS-20in no a 1<rq r 19VeaL recasrga C F., 1600 CFM -22:n ro.W. 104.2VAt recaige. . 0. Far ar8o+ re0�uenMrne ab— 1800 CFM• Do111 ai6e able a aan06w— al 1 S -ft We aw Oro DOD0111. a afe me" OMT. DIMENSIONS (In.) UNIT SIZE. A D E VENT CONN• 045-08 :. 14-3116 12-9/16 11-11/16 4 045-12: 14-3/16 12-9/16 11-11/16 4 070-08' 14-3116 12-9/16 11-11/16 4 070-12 14-3116 12-9/16 11-11/16 4 090.14 17-1/2 15-7/8 16 4 .090-16 21 19-3/8 18-1/2 4 111-12 17-1/2 15-7/8 16 4 - .11111-116. 21 19-3/8 18-1/2 4 '111-20 :. 24-1/2 22-7/8 22 4 .3,135-16 21 19-318 18-1/2 5 %-1.35-20 •: " 24-1/2 22-7/8 22 5 24-1/2 22-7/8 22 5 'Refer to the furnace Installation Instructions for proper venting procedures. peow 5 Performance data :UNIT :UNIT SIZE . oa5 . 08'12 . 070 sOS ]2 090. - 14 16'^: 12 16 '< 16- 6 .;.20•.;; `ii36:c r'::20 .. `:rS20 DIRECT -DRIVE MOTOR Hp (PSC) 0.7 1/5 1/3 1/5 1/3 1/3 1/2 1/3 1/2 3/4 1/2 3/4 3/4 MOTOR FULL LOAD AMPS C045-708- 2.9M5.82.9 855 5.8 5.8 7.9 5.8 7.9 11.1 7.9 11.1 11.1 RPM (Nominal) - SPEEDS 755 1075-3 695 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 1075-4 BLOWER WHEEL DIAMETERxWIDTHS(In.) 1410 10x6 1270 10x6 10x7 10x8 10x7 10x8 11x10 10x8 11x10 11x10 WASHABLE 16 x 25 x 1 -In. FILTER Oty 1 1095 1 1 - 1WASHABLE 1250 1205 1165 1120 20 x 25 x 1 -in. FILTER Oty -WASHABLE 805 Low 1070 1035 1010 970 930 875 24 x 29 x 1 -In. FILTER Oty High 1040 1010 975 935 880 810 735 640 PSC -Permanent Split Capacitor Med-High 855 830 800 765 _ 660 600 lk = Med-Low ENERGY EFFICIENCY V 045 070 080 W ,15S UNIT SIZE 08 1 12 :08 1''12 12 16 1'2 16 :20 16: .20 '':20 .. CAPACITY BTUH• Nonweatherized ICS 35.000 35,000 53,000 53,000 71,000 71,000 89,000 89,000 89,000 107, 107,W 124,000 AFUE%' Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 1 80.0 I 80.0 I 80.0 Capacity and AFUE in accordance with U.S. Government DOE test procedures. ICS -Isolated Combustion System AIR DELIVERY -CFM (With Filter)* 'Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. A fitter is required for each return -air supply. -Indicates unstable operating conditions. 6 EXTERNAL STATIC PRESSURE (In. UNIT SIZE SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.6 High 1030 1005 970 925 880 WP 815 745 615 C045-708- Med-High 855 830 800 765 720 670 595 485 Med-Low 755 725 695 650 605 555 475 400 High - 1485 1410 1350 1270 1180 1080 970 Med-High - 1375 1315 1240 1165 1095 1000 905 045'12:`• ', Med-Low 1250 1205 1165 1120 1060 985 905 805 Low 1070 1035 1010 970 930 875 805 720 High 1040 1010 975 935 880 810 735 640 070-08'�:. Med-High 855 830 800 765 715 660 600 490 = Med-Low 745 715 690 650 605 550 475 385 High - 1485 1'430 1365 1300 1220 1140 1045 '`1` Med-High - 1355 1305 1260 1200 1135 1055 960 070 -12.,..,.' - Med -Low 1175 1170 1140 1110 1055 1005 950 860 Low 1020 1015 995 970 930 885 825 745 High 1585 1540 1470 1410 1335 1220 1110 980 Med-High 1355 1325 1280 1230 1175 1090 1015 910 090=14r`` • ;:: Med-Low 1150 1125 1105 1085 1035 965 895 786 Low 960 950 935 910 880 815 715 580 High 2010 1950 1875 1810 1740 1660 1550 1455 Med-High 1675 1660 1625 1600 1545 1490 1395 1295 090-16„ Med-Low 1445 1430 1415 1400 1370 1325 1265 1170 Low 1260 1260 1260 1250 1210 1180 1115 1030 High 1490 1435 1370 1300 1210 1135 1020 880 Med-High 1375 1325 1265 1195 1125 1055 945 810 Med-Low 1205 1175 1130 1075 1025 925 830 675 Low. 1045 1020 1000 960 905 820 700 565 High 1880 1815 1745 1690 1575 1500 1400 1265 Med-High 1660 1615 1570 1505 1435 1355 1260 1170 111-16 -: Med-Low 1455 1410 1375 1350 12901235 1145 985 Low 1265 1265 1240 1210 1180 1110 995 855 High 2475 2405 2330 2265 2210 W 2130 2040 1945 Med-High 2055 2025 2000 1965 1930 1865 1795 1720 111-20 Med-Low 1725 1720 1705 1685 1665 1630 1585 1525 Low 1500 1515 1510 1500 1480 1460 1415 1370 High 1900 1845 1780 1705 1620 1530 1445 1320 Med-High 1695 1645 1580 1520 1460 1385 1280 1155 135-16 Med-Low 1460 1415 1375 1340 1290 1205 1110 - Low 1275 1260 1245 1230 1180 1135 - - High - 2210 2130 2055 1980 1895 1795 1680 Med-High 2015 1975 1925 1880 1805 1735 1655 1555 135 20 Med-Low 1730 1710 1670 1635 1590 1535 1470 1385 Low 1525 1520 1495 1450 1410 1375 1315 1245 High - 2145 2060 1975 1905 1600 1680 1565 Med-High - 1950 1885 1815 1710 1645 1545 1435 155 20 Med-Low 1730 1695 1660 1600 1540 1465 1400 1305 Low 1520 1500 1460 1410 1360 1310 1245 1155 'Air delivery above 1800 CFM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. A fitter is required for each return -air supply. -Indicates unstable operating conditions. 6 Product Data HEATING & COOLING Copyright 1997 Carrier Corporation '38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy -Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today, including SEER ratings of at least 12.0 when used with specific Carrier indoor sections. All models are listed with UL, c -UL, ARI, CEC, and CSA-EEV. The 38BRC meets the Energy Star- guidelines for energy efficiency. FEATURES/BENEFITS Electrical Range — All units are offered in single phase 208/230v. The 38BRC 036 through 060 models are offered in 208/230v 3 phase. Wide Range of Sizes —Available in 6 nominal sizes from 024 through 060 to meet the needs of residential and lieht commercial applications. Compressor — This unit features a scroll compressor. This compressor is significantly more efficient than conventional compressors. Its simple design offers improved reliability. Each compressor is mounted on rubber isolators for additional sound reduction. The scroll compressor will start under most system loads, minimizing the need for start assistance components. For improved serviceability, the 024 through 042 models are equipped with a compressor terminal plug. Continuous operation is approved down to 55T (12.8°C) in the cooling mode. (See cooling performance tables.) Operation down to 0°F or —20°F is approved when low -ambient requirements are met. Weather Armor H Cabinet — The access panels and top are protected Form 38BRC-1 PO 0 30' SO 1— M —� AIR IN AIR DISCHARGE AIR DISCHARGE FIELD POWER SUPPLY CONN Q O ° 7/6 -IN. DIA HOLE WITH 1 1/9 -IN. DIA KNOCKOUT DIA N KNOCKOUT 20- �r 271116- AIR IN FIELD CONTROL SUPPLY AIR IN -)P- 299/18• CONN 7/6 -IN. DIA 3/6 -IN. DIA 8 HOLE TIEDOWN KNOCKOUTS 3/8 -IN. DIA LIQUID (2) PLACES IN I 0 LINEICONN BASEPAN O o P 0 0 j AIR DISCHARGE I I 2 -_ 61/2' I AIR IN -0 23 1/2' -moi 0 OIA VAPOR LINE CONN -4 -- 271/4' �- f- 293/4' NOTES: 1. Allow 30 In. clearance to service side of _ unit, 48 In. above unit, 6 In. on one side, 12 In. on remaining side, and 24 In. between units for proper airflow. 2. Minimum outdoor operating ambient In cooling mode Is 55"F, max. 125°F. 3. Series designation Is the 13th position of the unit model number. 4. Center of gravity e. A97075 DIMENSIONS (IN.) MINIMUM UNIT MOUNTING PAD SIZE SERIES B C D M N P DIMENSIONS 024 30 27.15/16 3-3/16 5/8 14.3/4 14 /1 30 X 30 024 31 23-15/16 3.3/16 5/6 14.3/4 14 10 30 X 30 030 30 33-15/16 3-3/16 3/4 14-3/4 14 13 30 X 30 030 31 27.15/16 3-3/16 3/4 14.3/4 14 11 30 X 30 036 30.50 33.15/16 3.3/16 3/4 14.3/4 14 13 30 X 30 036 31 33.15/16 3-3/16 3/4 14.3/4 14 13 30 X 30 036 32,52 27.15/16 3-3/16 3/4 14.3/4 14 11 30 X 30 042 30,50 39.15/16 3.1/4 7/8 14-3/4 14 15 30 X 30 042 31 39-15/16 3-1/4 7/8 14.3/4 14 Is 30 X 30 042 32,52 33-15/16 3-1/4 7/8 14-3/4 14 13 30 X 30 046 30 33.15/16 3.1/4 7/8 15-1/2 14-3/4 13 30 X 30 048 32.52 33-15/16 3-1/4 7/8 15.1/2 14-3/4 13 30 X 30 060 30 39.15/16 3.1/4 7/8 15.1/2 14-3/4 15 30 X 30 060 32.52 39-15/16 3-1/4 7/8 15-1/2 14-3/4 15 30 X 30 Combination ratings UNIT INDOOR ii S12FSFAlFS I MnnFL CCSA/CD5A/CDSBA024- CCSA/CDSA/CDSBA030 CCSA/CD5A/CDSBW024 CCSA/CDSA/CDSBW030 CD3(A.B)A024 CO3(A,B)A030 CE3AA024 CE3AA030 CF5AA024 CG5AA024 CJ5A/CK5A/CKSBA024 CJSA/CKSA/CK5BA030 CJ5A/CKSA/CK5BW024 CJ5A/CK5A/CK5BW030 CK38A024 CK3BA030 CM5A/CM5B024 F(A,B)4AN(F,C)024 F(A,B)4AN(F,C)030 FC4BNF024 FC4BNF030 FC4BNF033 FD3ANA024 FO3ANA030 FF1(A.B.C)NA024 FF1(A,B,C)NA030 FG3AAA024 FK4CNF001 FK4CNF002 FK4CNF003 A31 CCSA/CDSA/CDSBA024 CCSA/CDSA/CD5BA030 CCSA/CDSA/CD5BW024 CCSA/CDSA/CD5BW030 CD3(A.B)A024 CD3(A.B)A030 CJSA/CKSA/CK5BW030 CK3BA024 rttzaen�n 030-30,31 See notes on pg. 15. CC5A/CD5A/CD5BA024 CCSA/CD5A/CD5BA030 CC5A/CDSA/CO5BW024 CC5A/CDSA/CDSBW030 CD3(A.B)A024 CD3(A.B)A030 CJ5A/CKSA/CKSBW024 CJ5A/CK5A/CK58W030 CK3BA024 CK3BA030 CC5A/C05A/CD56A024 CC5A/CO5A/CO5BA030 CC5A/CD5A/CD5BW024 CC5A/CO5A/CD5BW030 CD3(A.B)A024 CD3(A, B)A030 CJSA/CK5A/CK5BW024 CJSA/CKSA/CKSBW030 CK3BA024 CK38A030 CCSA/CDSA/CD5BA024 CC5A/CO5A/CO5BA030 CC5A/CDSA/CD5BW024 CC5A/CO5A/CO5BW030 CD3(A.B)A024 CD3(A,B)A030 CE3AA024 CE3AA030 CJ5A/CK5A/CK5BA024 CJ5A/CK5A/CK5BA030 CJSA/CK5A/CK5BW030 CK38A024 CCSA/CD5A/CO5BA030' CC5A/CDSA/CD5BA036 CCSA/CD5A/CO5BW030 ACCESSORY TXV# LLS 12.00 12.00 12.10 0112.10 12.00 12.00 12.10 12.10 12.00 12.00 12.10 12.10 12.00 12.00 12.10 12.10 12.00 12.00 - 12.00 12.00 12.00 12.10 1210 12.00 1200 1210 1210 12.00 12.00 12.10 1210 12.00 1200 12.00 - 1220 - 12.00 1200 12.20 12.20 12.00 - 12.20 - 11_80 11_80 10.80 10.90 10.80 10.90 10.80 10.90 10.90 11.00 10.90 10.90 10.80 10.95 10.80 10.95 10.80 10.95 11.10 10.90 11.15 10.90 11.15 11.35 11.00 11.05 10.80 11.05 10.65 12.30 12.40 12.70 SOUND RATING 13.00 - SEER 78 FACTORY- - CARRIER GAS 78 SUPPLIED - FURNACE OR TOT. CAP. ENHANCE- STANDARD ACCESSORY BTUH MENT RATING TDRt 23.000 NONE - 12.00 .23,400 NONE 12.10 - 23.000 NONE 12.00 23.400 NONE - 12.10 23.000 NONE - 12.00 23.400 NONE - 12.10 23.400 NONE - 12.00 23.600 NONE - 12.10 23.400 NONE - 12.00 23.400 TXV - 12.00 23.000 NONE - 12.00 23,400 NONE - 12.10 23.000 NONE - 12.00 23.400 NONE - 12.10 23,000 NONE - 12.00 23.400 NONE - 12.10 23.400 NONE - 12.00 23.200 TDR 12.00 - 23,600 TDR 12.20 - 23.200 TOR & TXV 12.00 - 23.600 TOR & TXV 12.20 - 24,000 TDR & TXV 12.40 23,200 NONE - 12.00 23.800 NONE - 12.20 23,200 TDR 12.00 - 23,400 TDR 12.20 - 23.000 NONE - 11.80 23,800 TDR & TXV 13.00 - 23,800 TDR & TXV 13.50 - 23.800 TDR & TXV 14.00 - COILS + SBMVP040-14 VARIABLE -SPEED FURNACE 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23,400 TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - COILS + 58MVP060-14 VARIABLE -SPEED FURNACE 23.200 TDR 13.00 - 23,400 .TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TOR 13.00 - 23,400 TDR .13.00 - 23.200 TOR 13.00 - 23.400 TOR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - COILS + 58MVP0SO-14 VARIABLE -SPEED FURNACE 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TOR 13.00 - 23.400 TOR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TDR 13.00 - 23.400 TDR 13.00 - COILS + 58U(H,X)VO60-12 VARIABLE -SPEED FURNAC 23.200 TDR 13.00 - 23.400 TDR 13.00 - 23.200 TOR 13.00 - 23.400 TOR 13.00 - 23,200 TDR 13.00 - 23,400 TDR 13.00 - 23.400 TDR 13.00 - 23,600 TDR 13.00 - 23,200 TDR 13.00 - 23.200 TDR 13.00 - 23,200 TDR 13.00 - 23,200 TOR 13.00 - 23.200 TOR 13.00 - 29.000 NONE - 12.00 29.600 NONE - 12.20 29,000 NONE - 12.00 29.000 NONE - 12.00 29.600 NONE - 12.20 29,600 NONE - 12.20 ACCESSORY TXV# LLS 12.00 12.00 12.10 0112.10 12.00 12.00 12.10 12.10 12.00 12.00 12.10 12.10 12.00 12.00 12.10 12.10 12.00 12.00 - 12.00 12.00 12.00 12.10 1210 12.00 1200 1210 1210 12.00 12.00 12.10 1210 12.00 1200 12.00 - 1220 - 12.00 1200 12.20 12.20 12.00 - 12.20 - 11_80 11_80 10.80 10.90 10.80 10.90 10.80 10.90 10.90 11.00 10.90 10.90 10.80 10.95 10.80 10.95 10.80 10.95 11.10 10.90 11.15 10.90 11.15 11.35 11.00 11.05 10.80 11.05 10.65 12.30 12.40 12.70 SOUND RATING 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.65 78 13.00 - 11.95 78 13.00 - 11.95 78 13.00 - 12.15 78 13.00 - 11.95 78 13.00 - 12.15 78 13.00 - 11.75 78 13.00 - 11.95 78 13.00 - 11.75 78 13.00 - 11.95 78 13.00 - 11.75 78 13.00 - 11.95 78 13.00 - 11.80 78 13.00 - 12.05 78 13.00 - 11.85 78 13.00 - 12.10 78 13.00 - 1210 78 13.00 - 11.85 78 13.00 - 12.10 78 12.00 120010.70 78 12.20 12.20 11.15 78 12.00 1200 10.70 78 12.00 1200 10.70 78 12.20 12.20 11.15 78 12.20 12.20 11.15 78 6 Combination ratings continued See notes on pg. 15. 14 SEER FACTORY- CARRIER GAS SUPPLIED FURNACE OR ACCESSORY SOUND UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY RATING TXV# I LLS IZE-SERIES MODEL BTUH MENT RATING TDRt EER dBA CC5A/CD5A/CD5BWO48 40.500 TDR 13.00 - 13.00 - 11.30 82 CD3(A,B)A042 40.000 TDR 12.50 - 12.50 - 11.15 82 CD3(A,B)A048 40,500 TDR 13.00 - 13.00 - 11.30 82 042-30,50, CDSA/CD5BA048 40,500 TDR 13.00 - 13.00 - 11.30 82 31, 32, 52 CE3AA042 40,000 TDR 13.00 - 13.00 - 11.20 82 CE3AA048 40,500 TDR 13.00 - 13.00 - 11.25 82 CJSA/CK5A/CK5BA042 40.000 TDR 12.50 - 12.50 - 11.35 82 CJ5A/CK5A/CK5BW048 40.500 TDR 13.00 - 13.00 - 11.50 82 CK3BA042 40,000 TDR 12.50 12.50 - 11.35 82 CD5A/CDSBA048' 47.000 NONE - 12.00 12.00 12.00 10.50 82 CC5A/CD5A/CD5BA060 47.500 arm, NONE 12.10 12.104io 12.10 10.55 82 - CC5A/CD5A/CD5BC048 46,000 NONE 12.00 12.00 12.00 10.40 82 CC5A/CD5A/CD5BWO48 47.000 NONE - 12.00 12.00 12.00 10.50 82 CC5A/CD5A/CD5BW060 47,500 NONE - 12.20 12.20 12.20 10.80 82 CD3(A.B)A048 47,000 NONE - 12.00 12.00 12.00 10.50 82 CD3(A.B)A060 47,500 NONE - 12.10 12.10 12.10 10.55 82 CE3AA048 47,000 NONE - 12.00 12.00 12.00 10.65 82 CE3AA060 47,500 NONE - 12.10 12.10 12.10 10.90 82 CF5AA048 47,000 NONE - 12.00 12.00 12.00 10.60 82 CGSAA048 47,000 TXV - 12.00 - 12.00 10.60 82 CJ5A/CK5A/CK5BA048 47,000 NONE - 12.00 12.00 12.00 10.45 82 CJ5A/CK5A/CK5BA060 47,500 NONE - 12.10 12.10 12.10 10.65 82 CJ5A/CK5A/CK5BN048 46,000 NONE - 12.00 12.00 12.00 10.45 82 CJ5A/CK5A/CK5BN060 47,500 NONE - 12.10 12.10 12.10 10.85 82 CJ5A/CK5A/CK5BW048 47,000 NONE - 12.00 12.00 12.00 10.45 82 CJ5A/CK5A/CK5BX060 47,500 NONE - 12.20 12.20 12.20 10.85 82 CK3BA048 47,000 NONE - 12.00 12.00 12.00 10.45 82 CK3BA060 47,500 NONE - 12.10 12.10 12.10 10.85 82 CM5A/CM5B048 46,500 NONE - 12.00 12.00 12.00 10.55 82 F(A.B)4AN(F.B)048 47,000 TDR 12.00 - 12.00 - 10.50 82 F(A.B)4AN(FB)060 47.500 TDR 12.10 - 12.10 - 10.60 82 FC4BN(F.B)048 47,000 TDR & TXV 12.00 - - - 10.50 82 FC46N(F.B)060 47,500 TDR & TXV 12.10 - - - 10.60 82 FC4BN8054 48.000 TDR & TXV 12.50 - - - 11.05 82 FG3AAA048 47,000 NONE - 12.00 12.00 12.00 10.50 82 FG3AAA060 48,000 NONE - 12.20 12.20 12.20 10.75 82 FK4CNB006 48,000 TDR & TXV 14.00 - - - 11.90 82 FK4CNF005 47.000 TDR & TXV 13.50 - - - 11.55 82 COILS + 58MVP080-14 VARIABLE -SPEED FURNACE CJ5A/CK5A/CK5BA048 47,000 TDR 12.00 - 12.00 - 10.60 82 CK3BA048 47,000 TDR 12.00 - 12.00 - 10.60 82 CK3BA060 47.500 TDR 12.50 - 12.50 - 10.75 82 COILS + 58MVP080-20 VARIABLE -SPEED FURNACE CC5A/CD5A/CD5BW060 47,000 TDR 13.00 - 13.00 - 11.25 82 048-30, CJ5A/CK5A/CK5BA048 47,000 TDR 12.00 - 12.00 - 10.50 82 32, 52 CJ5A/CK5A/CK5BA060 47,500 TDR 12.00 - 12.00 - 10.70 82 CJ5A/CK5A/CK5BN060 47,500 TDR 12.00 - 12.00 - 10.70 82 CJ5A/CK5A/CK5BX060 48.000 TDR 12.50 - 12.50 - 10.95 82 CK3BA048 47,000 TDR 12.00 - 12.00 - 10.50 82 CK3BA060 47.500 TDR 12.00 - 12.00 - 10.70 82 COILS + 58MVP100-20 VARIABLE -SPEED FURNACE CCSA/CD5A/CD5BW060 47,000 TDR 13.00 - 13.00 - 11.25 82 CJSA/CK5A/CK5BA048 47,000 TDR 12.00 - 12.00 - 10.80 82 CJ5A/CK5A/CK5BA060 47,500 TDR 12.50 - 12.50 - 11.00 82 CJ5A/CKSA/CK5BN060 47,500 TDR 12.50 - 12.50 - 11.00 82 CJ5A/CK5A/CK5BX060 48.000 TDR 13.00 - 13.00 - 11.25 82 CK3BA048 47,000 TDR 12.00 - 12.00 - 10.80 82 CK3BA060 47.500 TDR 12.50 - 12.50 - 11.00 82 COILS + 58MVP120-20 VARIABLE -SPEED FURNACE CC5A/CD5A/CD5BW060 47.000 TDR 13.00 - 13.00 - 11.25 82 CJ5A/CK5A/CK5BA060 47,500 TDR 12.50 - 1 12.50 - 11.00 82 CJ5A/CK5A/CK5BX060 48.000 TDR 13.00 - 13.00 - 11.30 82 CK3BA060 47.500 TDR 12.50 - 12.50 - 11.00 82 COILS + 58U(H,X)V080.16 VARIABLE -SPEED FURNACE CC5A/CD5A/CD5BW060 47,000 TDR 13.00 - 13.00 - 11.25 82 CE3AA060 47,000 TO 13.00 - 13.00 - 11.70 82 CJ5A/CK5A/CK5BA048 47,000 TDR 12.00 - 12.00 - 10.65 82 CK3BA048 47,000 TDR 12.00 - 12.00 - 10.65 82 CK3BA060 47,500 TDR 12.50 - 12.50 - 10.90 82 COILS + 58U(H,X)V100-20 VARIABLE -SPEED FURNACE CC5A/CD5A/CD5BW060 47,000 TDR 13.00 - 13.00 - 11.25 82 CE3AA060 47,000 TDR 13.00 - 13.00 - 11.70 82 CJ5A/CK5A/CK5BA060 47,500 TDR 12.50 - 12.50 - 11.35 82 CJ5A/CK5A/CK5BW048 47,000 TDR 12.50 - 12.50 - 11.10 82 CJ5A/CK5A/CK5BX060 48.000 TDR 13.00 - 13.00 - 11.60 82 CK3BA048 47,000 TDR 12.50 - 12.50 - 11.10 82 CK36A060 47,500 TDR 12.50 - 12.50 - 11.35 82 COILS + 58U(H.X)Vl20-20 VARIABLE -SPEED FURNACE CCSA/CDSA/CD5BW5;67 47,000 1 TDR 13.00 - 13.00 - 11.25 82 CE3AA060 47.000 TDR 13.00 - 13.00 - 11.70 82 See notes on pg. 15. 14 Combination ratings continued CJ5A/CK5A/CK5BA060 56,000 TDR 12.20 - 12.20 - 10.65 82 CJ5A/CK5A/CK5BX060 58,000 TDR 12.50 - 12.50 - 11.00 82 CK38A060 56,000 TDR 12.20 - 12.20 - 10.65 82 Tested Combination t In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor- mance. Use either the accessory Time -Delay Relay KAATD0101 TDR or a furnace equipped with TOR. All Carrier furnaces are equipped with TDR except for the 58GFA. t Based on computer simulation. TXV must be hand shutoff type. EER - Energy Efficiency Ratio LLS - Liquid -Line Solenoid Valve SEER - Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoorfindoor combinations have been tested in accordance with DOE test procedures for central air conditioners Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 15 SEER UNIT INDOOR TOT. CAP. FACTORY- SUPPUED ENHANCE- SOUND RATING STANDARD CARRIER GAS FURNACE OR ACCESSORY ACCESSORY TXV LLS SIZE -SERIES MODEL BTUH MENT RATING TDRt EER dBA) CJSA/CKSA/CK5BA060 47,500 TDR 12.50 - 12.50 - 11.25 82 048-30, 32,52 CJ5A/CK5A/CKSBW048 CJ5A/CK5A/CK5BX060 CK3BA048 47,000 48,000 47,000 TDR TDR TDR 12.50 13.00 12.50 - - - 12.50 13.00 12.50 - - - 11.00 11.50 11.00 82 82 82 CK3BA060 47.500 TDR 12.50 - 12.50 - 11.25 82 CC5A/CDSA/CD5BW060- ftm 58.000 M iiiiinP NONE 0 12.00 411111111 12.00 0 12.00 10.35 dw 82 oe 40 CC5A/C05A/CD58A060 56.000 NONE - 11.50 11.50 11.50 10.15 82 CD3(A.B)A060 56,000 NONE - 11.50 11.50 11.50 10.15 82 CE3AA060 58.000 NONE - 12.00 12.00 12.00 10.45 82 CJ5A/CKSA/CKSBA060 56,000 NONE - 11.50 11.50 11.50 10.55 82 CJ5A/CK5A/CK58N060 56,000 NONE - 11.50 11.50 11.50 10.75 82 CJ5A/CK5A/CK5BX060 58,000 NONE - 12.00 12.00 12.00 10.70 82 CK3BA060 56,000 NONE - 11.50 11.50 11.50 10.70 82 F(A,B)4AN(F,B)060 58,000 TDR 11.50 - 11.50 - 10.05 82 . FB4ANB070 58.500 TDR 12.00 - 12.00 - 10.50 82 FC48N(F,B)060 58,000 TDR&TXV 11.50 - - - 10.05 82 060-30, FC4BN8054 58.000 TDR & TXV 12.20 - - - 10.65 82 32, 52 FC4BNB070 FG3AAA060 58,500 57,500 TDR & TXV NONE 12.00 - - 11.50 - 11.50 - 11.50 10.50 10.30 82 82 FK4CN8006 59.000 TDR & TXV 13.00 - - - 10.95 82 COILS + 58U(H V100-20 VARIABLE -SPEED FURNACE CJ5A/CK5A/CK5BA060 56,000 TDR 12.20 - 12.20 82 CJSA/CK5A/CK58X060 58,000 TDR 12.50 - 12.50 - 11.10 82 CK3BA0f 56,000 TDR 12.20 - 12.20 - 10.80 82 COILS + 58U(H,X)V120-20 VARIABLE -SPEED FURNACE CJ5A/CK5A/CK5BA060 56,000 TDR 12.20 - 12.20 - 10.65 82 CJ5A/CK5A/CK5BX060 58,000 TDR 12.50 - 12.50 - 11.00 82 CK38A060 56,000 TDR 12.20 - 12.20 - 10.65 82 Tested Combination t In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor- mance. Use either the accessory Time -Delay Relay KAATD0101 TDR or a furnace equipped with TOR. All Carrier furnaces are equipped with TDR except for the 58GFA. t Based on computer simulation. TXV must be hand shutoff type. EER - Energy Efficiency Ratio LLS - Liquid -Line Solenoid Valve SEER - Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoorfindoor combinations have been tested in accordance with DOE test procedures for central air conditioners Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 15 american- W A T E R H E A T E R S RESIDENTIAL CAS W West Coast Models 6 -Year Tank Warranty 6 -Year Parts Warranty • Fused Ceramic Shield rm A tough, thick durable coat of blue cobalt ceramic is fused to the tank's interior surfaces at 16000 F, forming a corrosion -resistant lining for years of dependable protection and use. •Non -CFC Foam Insulation The tank is surrounded by a thick coat of non -CFC polyurethane foam to trap heat inside the tank, saving energy. •Dip Tube Carries cold inlet water deep into the tank to minimize temperature dilution of hot water. • Top T&P Valve Opening Temperature & Relief Valve shipped in the box for field installation. •3/4" Top Water Connections • 1/2" Gas Connection *Aluminized Steel Multiport Burner For even flame distribution, quiet operation high -efficiency combustion and low NOW. Propane models feature cast iron burners. • Combination Thermostat/ECO With factory -preset pressure regulator and built-in millivolt - powered energy cut-off for overheat protection. -Anode Rod Top -mounted, heavy-duty anode for added tank protection, extending the life of the tank. • Code Approvals CSA International certified, CEC and 1990 NAECA approved. All models are certified at 300 PSI test pressure and 150 PSI working pressure. Meets California Code Approvals for NOW emissions. • Drain Valve Non-metallic, corrosion- free drain valve. • Hand Hole Cleanout Available on G62 -40T34 -3N. Add CO to the model number. Copyright© by American Water Heater Company 2000. All rights reserved. E&W AL 6 -Year United Tank Warranty Heavy gauge steel is automaticalty formed, rolled and welded to assure continuous seams for Fused Ceramic Shield lining. Each tank is triple tested to ensure quality. 6 -Year Parts Warranty Original factory parts warranted for 6 years. For complete warranty information consult the written warranty of American Water Heater company at (800) 999-9515. AI 60t roared !b pal of da rat um be w Axed a uamill h my lam of by my MM, dacoric a mednicd, i6k Via WAV ad wwf4 a by aq idamdnn *W retied 5yam W&W pemc4m n .miig km Amerism flake %te IWW* 2/00 L -PG -2.1 a �i f '~ american- / W A T E R H E A T E R S l— DRAFT HOOD VALVE ANODE 0 A H OO O OO C I T.P o GAS VALVE DRAIN VALVE PROLine m 6 -Year Gas - West Coast Models For she TSP valve factory installed, add `W to model number. Dimensions and specifications subject to change without notice in accor- dance with our policy of continuous product improvement. Dimensions on all charts shown in inches. Inlet and outlet are on 8" centers. Ali units have 3/4" top water connections. 1/2" gas connections. For propane, substitute "P" for "N" in model numbers. "CO" model includes a hand We cleanout. "Also available with 12 -Year tank, 6 -Year parts warranty. Change "G62" to "G122" when ordering. +Not NOx approved. ,Specification Residential gas water heater(s) shall be model as manufactured by American Water Heater Company, or an approved equal, and shall have a -year tank warranty and a -year parts warranty, when Installed in a residential application. When installed in a commercial application, the unit will have a 1 -year tank warranty and a 1 -year parts warranty. Heater(s) shall have a storage capacity of gallons and shall have a rated in- put of BTU's, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI 221.10.1 -CSA 4.1. Heaters shall meet or exceed the requirements of the Federal "National Appliance Energy Conservation Act of 1987." The inte- rior of the storage tank shall be lined with a Fused Ceramic Shield" lin- ing, fused to the tank at 1600° F, forming a corrosion -resistant lining; polymer linings are not acceptable. Each tank shall be furnished with an Internal anode for anodic protection. The unit must be equipped with a combination gas control thermostat and non -reset type ECO. A corro- sion -resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted and insulated with a non -CFC foam to reduce stand-by heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure. Order Entry and Sales P.O. Box 4056, 500 Princeton Road Johnson City, TN 37602-4056 (800) 937-1037 (800) 581-7224 fax Product Service and Support P.O. Box 1597, 500 Princeton Road Johnson City, TN 37605-1597 (800) 999-9515 (800) 999-5210 fax Aro%mmviNoMdlisrodmarberepodxedwoomiRd'aosryfroab/mrncas,deNaiwoedxrid 9V wl*9andrecadngwb�/itasmobmworeretredsrstegr/xWD��dr16gImoMecmlimnflmta(mgnR 21W L -PG -2.1 b INPUT G.P.H. MOTU RECOVERY HEIGHT PER HR. (90' RISE) JACKET APPROX. MODEL NUMBER GAL CAP. NAT. LP NAT. LP VENT DIA. E. F. DIA. A VENT B HEATER SIDE T8P c D SHIP WE G62 -30T33 -3N" 30 33,000 33,000 33.4 33.4 3 0.61 18 59-1/4 56 49.12 113 G62 -40T34 -3N 40 34,000 34,000 34.4 34.4 3 0.62 20 60-1/4 57 50-12 127 G62 -40T34-3= 40 34,000 34,000 34.4 34.4 3 0.62 20 60-1/4 57 50-12 127 G62 -40T40 -3N" 40 40,000 40,000 40.5 40.5 3 0.60 20 61-12 58-1/4 51-314- 137 G62 40T46-0111"+ 40 46,000 46,000 46.5 46.5 4 1 0.58 20 61-12 58-1/4 51-Y4 139 35.5 35.5 3 1 0.60 22 G62 -50T50 -4N" 50 50,000 50,000 50.7 50.7 4 1 0.57 22 60-1/4 57 50-12 160 For she TSP valve factory installed, add `W to model number. Dimensions and specifications subject to change without notice in accor- dance with our policy of continuous product improvement. Dimensions on all charts shown in inches. Inlet and outlet are on 8" centers. Ali units have 3/4" top water connections. 1/2" gas connections. For propane, substitute "P" for "N" in model numbers. "CO" model includes a hand We cleanout. "Also available with 12 -Year tank, 6 -Year parts warranty. Change "G62" to "G122" when ordering. +Not NOx approved. ,Specification Residential gas water heater(s) shall be model as manufactured by American Water Heater Company, or an approved equal, and shall have a -year tank warranty and a -year parts warranty, when Installed in a residential application. When installed in a commercial application, the unit will have a 1 -year tank warranty and a 1 -year parts warranty. Heater(s) shall have a storage capacity of gallons and shall have a rated in- put of BTU's, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI 221.10.1 -CSA 4.1. Heaters shall meet or exceed the requirements of the Federal "National Appliance Energy Conservation Act of 1987." The inte- rior of the storage tank shall be lined with a Fused Ceramic Shield" lin- ing, fused to the tank at 1600° F, forming a corrosion -resistant lining; polymer linings are not acceptable. Each tank shall be furnished with an Internal anode for anodic protection. The unit must be equipped with a combination gas control thermostat and non -reset type ECO. A corro- sion -resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted and insulated with a non -CFC foam to reduce stand-by heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure. Order Entry and Sales P.O. Box 4056, 500 Princeton Road Johnson City, TN 37602-4056 (800) 937-1037 (800) 581-7224 fax Product Service and Support P.O. Box 1597, 500 Princeton Road Johnson City, TN 37605-1597 (800) 999-9515 (800) 999-5210 fax Aro%mmviNoMdlisrodmarberepodxedwoomiRd'aosryfroab/mrncas,deNaiwoedxrid 9V wl*9andrecadngwb�/itasmobmworeretredsrstegr/xWD��dr16gImoMecmlimnflmta(mgnR 21W L -PG -2.1 b Page 146 SECTION I - GASWATER HEATERS October 2000 Rated Ist Hr Storage Model Foot Rasing, Energy Vol. Input Number Notes Gals. Factor Gals. MBTUH AMERICAN WATER HEATER COMPANY Trade Name(s): ACE, American, American Hardware, America's Best, Apex, AquaTemp., AquaTherm, Aquamatic, Beit, Best Deluxe, Champion, CraRmaster, De-Limer, Deluxe, Eagle, The Earl's Energy Conservation Water Heater, The Earl's Energy Saver Plus, Envirotcmp, Four Most, Hotmaster, Hotstream, King-Klceri, King -Line, Master Plumber, Nationaline, Neptune, Penquin, Premier Plus, Premier Plus Self Cleaning Prestige, ProLine and Proline Plus, Quaker, Quick -Flo, Raywall, Revere, Riveria, Sands, Sentinal, Servi-Star, Shamrock, Special Deluxe, Standard, Super Eagle, Super -Flo, Supreme, Sure -Fire, Thoro-Clean, Tru -Test, Tru Value, U.S. Supply, XCL Energy Saver NATURAL GAS MHSCGII.30T30-3N'•• 2,7 49 .57. , 30 30.0 76 MHSCG51-30T30-3N•'• 2.7 49 -57 30 30.0 76 MHSCG61.30T3D-3N•" 2.7 49 .57 30 30.0 76 FG10130s303N•1• 7 50 .58 30 30.11) 76 ' FGI130 ON- 7 50 .58 30 3D.0 76 FG12130S303N••• 7 50 :56 30 30.0 76 FG513OS303N••• 7 50 .58 30 30.0 76 FG6130S303N••• 7 50 .58 .30 30.0 76 o F98130S303141• 7 50 .58 30 30.0 76 FG9130S➢0W" 7 50 .58 30 30.0 76 G101-30530-314'•• 7 50 38 30. 30.0 76 Gil -30S30 -3N'•• 7 50 -58 30 30.0 76 G121.30S30-3N•'• 7 50 .58 30 . 30.0 76 G51.30S30.314- 7 So 38 30 30.0 76 G81.30S30.3W 7 so 38 30 30.0 76 681-30S30.3N•" 7 50 38 30 30.0 76 691-30S30-314•:' 7 50 .58 30 30.0 76 MHG11-30731-3N••' 1.2.7 53 36 30 31.0 75 MHG51-30T31-3N'•• Ir.7 53 .56 30 31.0 75 MHG61-30T31-3N•'• 1,2.7 53 36 30 31.0 75 MHSCG1140T30.3N••• 2.7 54 -56 40 30.0 76 mRscr,5l40T30.3N•'• 2.7 54 .56 40 30-0 76 MHSCG6140T30-3N••• 2.7 54 .56 40 30.0 76 G101.30T33.314- 7 54 .58 30 33.0 76 (311-30133-3N••• 7 54 .58 30 33.0 76 G121.30T33.3N'•' 7 54 .58 30 33.0 76 G51 -30T33 -3N'•' 7 54 .58 30 33.0 76 G61 -30T33 -3N•1• 7 -3: * 38 30 33.0 76 G81 -30T33 -3N"' 7 54 .58 30 33.0 "76. G91 -30T33 -3N'•• 7 54 .58 30. 33.0. 76 6102-30T33-314 =•• .7 54 .61 30 33.0 76 G122 -30T33-314-1 . 7 54 .61 30 -33.0 76 G12-30733-314••• 7 54 .61 30 33.0 76 G52 -30T33.314- 7 54 .61 30 33.0 76 9 G62.30T33-3N••• 7 54 .61 30 33.0 76 G82.30T33-314- 7 54 .61 30 33.0 - 76 G92.30T33-3N••• 7 54 .61 30 33.0 76 MHG11-40F31-3N••• 2,7 60 35 40 31.0 75 Ml4651.40T31.3N••' 2,7 60 .55 40 31.0 75 MHG61-40731-3N••' 2.7 60 .55 40 31.0 75 DVG102AOS38-N'•• 1,4,7 60 39 40 38.0 76 DVG)22-40538-N••• 1,4.7 60 .59 40 38.0 76 DVG12-40538-N••• 1,4.7 60 .59 40 ' 38.0 76 DVG5240S38-N••• 1,4,7 60 .59 40 38.0 76 1)VG6240S38-N1'• 1.4,7 60 .59 - 40 38.0 76 1)VG8240S38-N'•' 1,4.7 60 39 40 39.0 76 DVG9240S38•N••• 1,4,7 60 .59 40 38.0 16 G101.40S33.3N••• 7 62 36 40 33.0 77 G11-40533.314'•• 7 62 .56 40 33.0 -77 G12140S33-3N••' 7 62 36 40 33.0 77 (35140533.314"• 7 62 .56 40 33.0 77 G6140S33-3N••• 7 62 - .56 40 33.0 77 G8140S33-3N••• 7 62 .56 40 33.0 77 1st Hr Sdrage ery Model Foot Rating, Energy Vol. Input Recovery % Number Notes Gals. Factor Gals. MBTUH Effcy. %. G91 -40533-3N••' 7 62 .56 40 33.0 77 FG10140T343N••' 7 63 .57 40 33.0 77 FG1140T343N••• 7 63 .57 40 33.0 77 FG1214OT343N••• 7 63 .57 40 33.0 T7 FG5140T343N••' 7 63 -57 40 33.0 77 FG6140T343N'•• 7 63 .57 40 33.0 77 FG81407343N"• 7 63 37 40 j3.0 77 FG914DT343N'•' 7 63 .57 40 33.0 T7 ' G10140T34-3N••• 7 63 .57 40 .34.0 77 G1140734.3N•'• 7 63 37 40 34.0 77 G12140T34-3N"• 7 63 37 40 34.0 77 G51 -40734-3N••• .7 - 63 .57 40 34.0 77 G6140T34-314••• 7 63 .57 40 34.0 77 G81-40T34.3N•*-' 7 63 37 40 W.0 77 G9141734.314"• 7 63 37 40 34.0 77 - s G10249T34.314"' 1.7 63 .61 - 40 34.0 77 6 G12240T34.3N••• - 17 63 '.61 40 34.0 77 e G1 2-40734-314••• 17 63 .61 40 34.0 77 1652-40734-314••• 1,7 63 .61 40 34.0 77 0 it G6240T34-3N••• 1.,7 63 .61 40 34.0 77 0 G8240T34.3N••• 17 63 .61 40 34.0' 77 (39240734-3N•'• 17 63 .61 40 34.0 77 • G10140S40-314••• 7 65 .55 40 40.0 76 a G11=40540-314••• 7 65 -55 40 40.0 76 0'G12140540-314'•• ' 7 65 .55 40 40.0 76 (35140540-314••• 7 65 35 40 40.0 76 NATURAI GAS G51 -50T40.314••• 7 79 35 50 40.0 76 (361.30735.314'•• 7 79 .35 50 35.0 76 G61.507`40.314••' 7 79 35 50 40.0 76 G81-50T35.3N••• 7 n 35 50 35.0 78 G81 -50T40 -M- 7 79 SS 50 40.0 76 ' G91-50735-314••• 7 79 35 .50• 35.0 :78 G91.50T40-3N••' 7 79 .55 50 40.0 - 76 G102-50735.314••• 1.7 79 .60 50 3S.0 78 G122-50735-314••' 1,7 79 .60 50 35.0 78 . G12 -50735-3N••' 1.7 79 .60 '50 35.0 71 G52.50T35-3)4•'• - ),7 79 .60 50 35.0 78; . • G62 -50735-3N"• 1.7 79 .60 50 35.0 78. G92-SOT35-314••' 1.7 79 .60 50 31.0 78 G92.50T35=3N•'• t 7 79 .60 50 35.0 78 (3101-50T504N•" 7 87 .53 50 50.0 76 ' 0 Gil-50T304N'•• 7 87 .53 50 50.0 76 GI21.507504N••' 7 87 .53 50 50.0 76 • GSI-50T504N••• ' 7 ' 87 .53 5o 50.0 76 e G61-50T504N•'• 7. 87 33 50 '50.0 76 a G81 -501504N"' 7 87 33 50 50.0 76 G91-50750414- 7 87 35 50 50.0 76 'G102.50750 -4N••• 6.7 87 .56 50 50b 76 C •G 122.50T5"N•'• 6.7 .87 -56 50 50.0 76 s •G12 -50750-•7N'•• 6.7 87 S6 50 50.6 76 �0 -G62-50T30414 ... 6.7 87 36 50 50.0 76 a •G92-50TS04N• 6.7 87 36 50 50.0. ,- 76 'PVG1D2-50763-3NH• 1,3.6.7 95 .60 50 63.5 76 'PVG122-50763.3NH•'• 3.3,6.7 95 .60 50 633 76 'PVG12.50T63-3NH••' 1.3.6,7 95 .60 50 '63.5 76 •PVG52-50T63-3NH'•• 13.6.7 95 .60 50 63.5 76 'PVG62-50T63-3NH••• 13.6.7 95 .60 50 63.5 76 •1'VG82-50763.3NH••' 13.6,7 95 .60 50 63.5 76 •PVG92.5076-3NH••• 3,3.67 95 .60 50 633 76 •G102-50T634N'•• 67 96 33 50 63.0 76 •G122.50T634N••' 6,7' 96 .53 50 63.0 76 -G12-50T634N••• 6.7 - % 33 50 63.0 76 •G52-50T634N••• 6.7 96 . 33 50 63.0 76 ••G62-50T634N••' 6.7 96 .53 50 63.0 76 'G82 -507634N••• 6.7 96 .53 50 63.0 76 -G92-50T634N••• 6.7 % .53 50 63.0 76 Sterdad Fmtmta. 1. Hca trgn Z. Mou6ctu4d1Ab61e) H-, M.M 9 Ibrire Vd... mly -id sign bu dacrvp. g Rm6.-isedbypw yn¢ Int di -.a , P r LIINE W; 10 RM 0��.. 4'_ - � - - M W A T E R H E A T E R S RESIDE CAS UL7MwH1GH REC tWRY 6 -Year Tank Warranty 6 -Year Parts Warranty • Super Eagle Performance® High recovery and high performance for applications requiring higher inputs such as space heating. • Fused Ceramic Shield TM A tough, thick durable coat of blue ceramic is fused to the tank's interior surfaces at 1600° F, forming a corrosion -resistant lining for years of dependable protection and use. • Non -CFC Foam Insulation The tank is surrounded by a thick coat of non -CFC polyurethane foam to trap heat inside the tank, saving energy. • Dip Tube Carries cold inlet water deep into the tank to minimize temperature dilution of hot water. • Side UP Valve Also available with top T&P opening for field -installed top T&P valve. • Top and Side Water Connections Top water connections on 40- and 50 -gallon models are for domestic hot water. Side connections are for space heating applications 75 -gallon model has I" top water connections and 3/4" side connect- ions for space heating. I00 -gallon has 1-1/4" top connections only. • 1/2" Gas Connection •Aluminized Steel Multiport Burner For even flame distribution, quiet operation and high -efficiency combustion. Propane models feature cast iron burners. • Combination Thermostat/ECO With factory -preset pressure regulator and built-in millivolt -powered energy cut -of for overheat protection. •Anode Rod Top -mounted, heavy-duty anode for added tank protection, extending the life of the tank. • Code Approvals CSA International certified, CEC and 1990 NAECA approved. All models are certified at 300 PSI test pressure and 150 PSI working pressure. •Drain Valve Non-metallic, corrosion -free drain valve. • Cleanout Port 4" Diameter cleanout/inspection port standard on 100 gallon model. Copyright© by American Water Heater Company 2000. All rights reserved. MADE IN % Ole At 6 -Year Umited Tank Warranty Heavy gauge steel is automatically formed, rolled and welded to assure continuous seams for Fused Ceramic Shield lining. Each tank is triple tested to ensure quality. 6 -Year Parts Warranty Original factory parts warranted for 6 years. For complete warranty information consult the written warranty of American Water Heater Company at (800) 999-9515. bl ^� mened. Ib pot d tFb ■ot m%h repeodoted o Immdled "n ary lam a b� a4 mews, e4xAori[ o mednitd, i�d�3q t�eDY�9 � rttadeq � f9r aq irlmidm stem¢ eetird snteq ■Glnui panssian n wri6q lmm brcti�m Wme deme (arpm} . 2100 L-PG-2.Oa 54i B I C GAS VALVE A Tom ar"e"cdv"' W A r E H H E A r E A S DRAFT HOOD SIDE D SIDE INLET DRAIN VALVE NOTE. 40-, 50- And 75-9allon modeb haw side connections for space heating applications. 100 -gallon model has top water connections only. PROLineTnl 6 -Year Gas Ultra High Recovery Delete "V" in model number for top T&P option, T&P opening on top of the heater with the valve shipped in the box for field installation. For propane, substitute "P" for 'N" in model numbers. Also available with 12 -Year tank, 6 -Year parts warranty. Change "G62" to "G122" when ordering. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement *Based on 100' Rise. Specification Residential gas water heater(s) shall be model as manufactured by American Water Heater Comparry, or an approved equal, and shall have a -year tank warranty and a -year parts warranty, when installed In a residential ap- p6cation. When installed in a commercial application, the unit will have a 1 -year tank warranty and a 1 -year parts warranty. Heater(s) shall have a storage capacity (A gallons and shag have a rated input of BTU's, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI 221.10.1 or .3 -CSA 4.1 or .3 standard. Heaters shag meet or exceed the requirements of the Federal 'National Appliance Energy Conservation Act of 1987." The interior of the storage tank shag be lined with a Fused Ceramic Shield— lining, fused to the tank at 1600° F, forming a corrosion -resistant lining, polymer fin- ings are not acceptable. Each tank shag be furnished with an internal anode for anodic protection. The unit must be equipped with a combina- tion gas control thermostat and non -reset type ECO. A corrosion -resis- tant drain valve shall be provided on the front of each unit The tank shall be totally encased in a steel jacket, painted and insulated with a non -CFC foam to reduce stand-by heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure. 100 Gallon model shall have 4" diameter boiler -type cleanout/inspection port Order Entry and Sales P.O. Box 4056, 500 Princeton Road Johnson City, TN 37602-4056 (800) 937-1037 (800) 581-7224 fax Product Service and Support P.O. Box 1597, 500 Princeton Road Johnson City, TN 37605=1597 (800) 999-9515 (800) 999-5210 fax b nods mored Ib pot d Ais nod mos d<rtpodreeda oomdled'o ace bvn a b! ace mese. elcnait a n¢dvicd irkdig D�aGN9 � m�aA o a' a7 itano6on Haag aacrd sr9aq ellnA pen®on io mtiq ban hream Mme Mase lmpoNt . 2100 L-PG-2.Ob INPUT G.P.H. MBTU RECOVERY HEIGHT PER HR. (90- RISE) JACKET APPROX. MODEL GAL NAT. LP NAT. LP VENT DIA. E.F. VENT HEATER SIDE TAPSHIP NUMBER CAR Du1 A B C D WE G62-40T60-4NV 40 60,000 60,000 60.7 60.7 4 0.54 20 63 59-1/2 53-1/4 154 G62-75T75-4NV 75 75,100 75,100 76.9 76.9 4 0.51 26 6318 60 53-1/4 251 Delete "V" in model number for top T&P option, T&P opening on top of the heater with the valve shipped in the box for field installation. For propane, substitute "P" for 'N" in model numbers. Also available with 12 -Year tank, 6 -Year parts warranty. Change "G62" to "G122" when ordering. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement *Based on 100' Rise. Specification Residential gas water heater(s) shall be model as manufactured by American Water Heater Comparry, or an approved equal, and shall have a -year tank warranty and a -year parts warranty, when installed In a residential ap- p6cation. When installed in a commercial application, the unit will have a 1 -year tank warranty and a 1 -year parts warranty. Heater(s) shall have a storage capacity (A gallons and shag have a rated input of BTU's, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI 221.10.1 or .3 -CSA 4.1 or .3 standard. Heaters shag meet or exceed the requirements of the Federal 'National Appliance Energy Conservation Act of 1987." The interior of the storage tank shag be lined with a Fused Ceramic Shield— lining, fused to the tank at 1600° F, forming a corrosion -resistant lining, polymer fin- ings are not acceptable. Each tank shag be furnished with an internal anode for anodic protection. The unit must be equipped with a combina- tion gas control thermostat and non -reset type ECO. A corrosion -resis- tant drain valve shall be provided on the front of each unit The tank shall be totally encased in a steel jacket, painted and insulated with a non -CFC foam to reduce stand-by heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure. 100 Gallon model shall have 4" diameter boiler -type cleanout/inspection port Order Entry and Sales P.O. Box 4056, 500 Princeton Road Johnson City, TN 37602-4056 (800) 937-1037 (800) 581-7224 fax Product Service and Support P.O. Box 1597, 500 Princeton Road Johnson City, TN 37605=1597 (800) 999-9515 (800) 999-5210 fax b nods mored Ib pot d Ais nod mos d<rtpodreeda oomdled'o ace bvn a b! ace mese. elcnait a n¢dvicd irkdig D�aGN9 � m�aA o a' a7 itano6on Haag aacrd sr9aq ellnA pen®on io mtiq ban hream Mme Mase lmpoNt . 2100 L-PG-2.Ob