Loading...
0110-284 (SFD)F7 LICENSED CONTRACTOR DECLARATION I hereby affjrm uhder penalty of perjury that, I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and --Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 768972 131C 098101V,� iDate !_' 5'2S -Q -,Signature of Contrac7tor OWNER-BUILDER'DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business &Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ' ' () I am exempt under Section B&P.C. for this reason Date Signature of,Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for, by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. k•) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier 1y'fi,?1 Ie FUND Policy No. W6936M (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become -- subject to the workers' compensation provisions of Section 3700 of the -Labor J Code, I shall forthwith comply with those provisions. Date: / ^ 1. tQPPlieant ° %•' y- ^ ! ,f -•-''� Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued'as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize. representatives of this City to enter ,upon- the above-mentioned perty'for inspection purposes.. Signature (Owner gent)_ f�- �°"� -''Date BUILDING PERMIT PERMIT/t 4' DATE VALUATION— LOT TRACT JOB SITE�•�•,.�- ADDRESS t� CITRUS R•t- S 71 sorb �Et� OWNER CONTRACTOR/DESIGNER/EN (NEER P i M R R & K.Krl-I RYIb7 L 1r,1.:�.,3L.xx.R CABINX1181 BY M+:CIA 1i; 84 WORKS INC e) -103 WDi :1t? BLVD VMS D• ) 8 €110) D4131L') :r3S. VD, DUP-119 D) a 1=40 CA 92201 TWD.110 (A MCA (760)342-11 -,11 MIA 5392 USE OF PERMIT i P_V-Rfw'I1' 12tXJMNOT 3NCI,1JOB SLOCK Wysl.,i,,�5, P001:, R;+X DRIV9*rYAY APPROACH. (`1,TST014 C'iONS a RUC 1'I -T14 4,4:53,OD SF Tri?RCi�l/pIk io 1 ' 792.1110 Syr WNW `i FF' StI:IO{!1 fly t':..XXCHWXty1?:t $1;VA.1.5 Ml; DEPOSIT Sl,t1aw 10,901A.N11CAdPiE 1Ci''.- 3-QC!J $150.06 ELECTRICAL FUR '101-000-420-000 $24G. b4 101.006.419 -Wo $404.25 STROM tdt01,10.14 frit • 11F641D 1.01.000- 1-M10 $,s''' 4 DEVE-URFA IMPACT _01YX $1,907,0 ART 114 PUBLIC 1' l,hCES ,, RX21t 210-000-44 55-000 SiJ i-`PCy:65" ( CoiMSMPIK"t.1C?I,IAND �y.t, AW CURML `�,CanS •��..3:� usis PRE -PAIDe 1740 PERM -III; now -$1,000,00 JAN 23 2002 C1TY0FLAQUp SFA RECEIPT DATE 7 BY---'` DATE FINALED 41 INSPECT 4.> i :r INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs —IZ=g2— Underground Ducts Forms &Footings�/— d --- Ducts Slab Grade Return Air Steel //— L Combustion Air Roof Deck O.K. to Wrap O _ _ j_ Exhaust Fans F.A.U. Framing I Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final _ — Final a BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines — , Cj 2— Heater Final Water Piping Plumbing Final Plumbing Top Out Shower Pans _ > C Equipment Enclosure O.K. for Finish Plaster Sewer Lateral Sewer Connection Pool Cover Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Z Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility. Notice (Perm) COMMENTS: Certificate of Occupancy W: 4 G� OF TBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78-820 CITRUS Use classification: S.F.D. Building Permit No.: 0110-284 Occupancy Group: R-3 Type of Construction: R-3 Land Use Zone: R -L Owner of Building: PIERRE& KATHRYN LETIELLIER Address: 81-101 INDIO BLVD STED-18 City, ST, ZIP: INDIO CA. 92201 By: G. SHOWALTER ^dj^� Date: 04/08/04 Building Offi lal POST IN A CONSPICUOUS PLACE P.O. BOX 1504 Building �% Q T 78-495 CA Address / Y —U a / ! tu S LA OUINTA, C vwner Mailing r -`Hr A Address (, . r.. I�'i HDO Y ; � - 7 i IJli�i �_ I City r_ Zip;. 7)'2 � -, Contractor p�yrc--N ' L KI,_-�T i r T-1 Lj Address City- i r1t�,� I �1- - �- Zip ,. Tel. 71 %I -I I State Lic. r & Classif. , 1 �I �^ j` City Lic. # Arch.,-Engr., _ <Designerl ._.ITF-,��- _ Address I_ Tel. r) {{City �f Zip _ _ State 7 —} r— t Lic. # 1 'i 1 `' LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section TODD) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Susiness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). l: 1, as owner of the property, or my employees -with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is 'sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) 1 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) t? 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION 1 hereby.affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company (7 Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall ^not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have -read this application and state that the above information is correct. I agree to comply With all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip LLE TAMPICO APPLICATION ONLY w, ALIFORNIA 92253 O^ ` 9 / BUILDING: TYPE'CONST. / L`/fOCC.G•RP. A.P. Number T4d �t -=�n Legal Description �� 1 � 1te�. Irl O O Project Description `�7> Sq. Ft. �1C,�) No. Size I 1 Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ ~ Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line Estimated Valuation FINAL DATE PERMIT AMOUNT Plan Chk. Dep. /err Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. (, n Infrastructure TOTAL (' REMARKS WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION ZONE: i BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: - - WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Desert Sands Unified School District 47-950 Dune Palms Road Notice: La Quinta, CA 92253 Document Cannot Be Duplicated 760-771-8515 CERTIFICATE OF COMPLIANCE Date 1/23/02 No. 22852 Jurisdiction owner NamePierre & Kathryn Lettellier No.78820 Street Citrus city La Quinta Zip 92253 APN # 772-080-002 La Quinta Permit # I_og # 0110-284 Study Area Tract # 24890-4 Lot # 14 Square Footage 4453 Type of Development Single Family Residence Comments Single Family Residence 4453 sq.ft. a No. of Units 1 a At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2.05 X 4,453 or $ 9,128.65 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By CC/ First Bank - Dan Dryden Telephone Name on the check By Dr. Doris Wilson y' Superintendent Fee collected /exempted by Nicola Wong Payment Received $9,128.65' . %� � Check No. 61316 Signature � � , ulJ m,, NOTICE: Pursuant to Assembly Bill 3081 (CHAP 549, S ATS. 996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the buildin o stallation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to collect them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting 09/25/01 TUE 16:28 PAX 760 398 9018 D R M September Katherine & Pierre Letailier Suite D-18 lndie; .0.4.132801........ RE, Architectural Request Citrus Course Hotn`ebWhiirs Rssociatiodh,, Lot 44 — 78-820 Citrus Dear Mr. & Mrs. Letellier. Tft letteristrrcortffim; in Committee has approved your application for the custom home located at 78-820 Citrusla subrrutt+ed~orr .... ..... .. .tulq-4f •20@t-and~9epternber-12--290texceptlorr•ot"tht•exRertar•c'�� scheme. Significant sections of the house are to be painted three different colors and the ; _...._ ...scheTncis esiRthe t usionrho 'e'"door�tar�ttir ` 'fttis,00lor rne� development and may be too different oombined with the contemporary architecture to tx' =Mtabfe. home contingent on the committee's further review and acceptance of the exterior color - g me. "rs thet W6 pf iF09a0eft, peel.mnd dee"n that has been drawn by a pool contractor for review and approval by the landscaping end+ _..._.. jvjeet Vme beenzeapleled;_pteese-r►atiftrtbis-ofReb-lftvrriangso improvement can be inspected and signed off by the Architectural Committee. Pleeaeti'Otrtact mem . ncgOppn. :.............. _.......... .. Sincere Association Manager orrbahar,?the ArCNt=WratIZevfeara`i_M Citrus Course Homeowners Association i i plefegg"W Gem i.. Post Office Box 4772 -Palm Desert, CA 9226 1-47 72 : "1 73-550 Llfil �.FqX 91ii WiVVr R'AIRWAY HOMES lrTe'rNo. Escrow No. Loan No. Recording Requested By First American Title Company WHEN RECORDED MAIL TO: Mr. and Mrs. Pierre Letellier 39559 New Castle Dr. Palm Desert, CA 92211 MAIL TAX STATEMENTS TO: SAME AS ABOVE TRA: 020-051 DOC p 2001-271657 06/15/2001 08:00A Fee:12.00 Paye 1 of 3 Doe T Tax Paid Recorded in Official Records County of Riverside Gary L. Orso Assessor, County Clerk 8 Recorder IIIIII IIIIIII III IIII IIII M $ U PAGE SIZE DA PCOR NOCOR SMF misc. �i A I R I L 11 COPY LONG REFUND NCNG EXAM xx Computed on the consideration or value of property conveyed; OR - I Computed on the consideration or value less liens or encumbrances remaining at time of sale THE UNDERSIGNED GRANTOR 1 Signature of Declarant or Agent determining tax -Firm Name SF 101 �2.. SO GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, CAPITAL PACIFIC HOLDINGS, LLC, a Delaware Limited Liability Company hereby GRANT(S) to PIERRE LETELLIER and KATHRYN LETELLIER, husband and wife as joint tenants the real property in the City of La Quinta County of Riverside State of California, described as Lot 14 Tract No. 248904 (See Exhibit "A" Attached Hereto) i Dated: June 4, 2001 State of California ) ) ss. CAPITAL PACIFIC HOLDINGS,LLC, County of '' ve i -) a Delaware limited liability company On o before�e, BY: CAPIT PACIFIC HOLDINGS,INC., 1� I 1 a Delawar rporation, Managing Member personally appeared O o personally known to me ( BY: �evideaee) to be the person( whefe name(* is/a� subscribed to the Vi Ce P.O-.-.� All within instrument -and acknowledged to me that he/skehhey executed the same in his/l e�eir authorized capacityice, and that by his/l=kheir $ _ p) signature( on the instrument the person(si or the entity upon behalf of which the person acted, executed the instrument. LAURA L. GODWIN WITNESS MY AND O I SEL Commission # 1263876 Notary Public - Caiifomia Signature Riverside County My Comm. Fires Mo y 14, 20D4 (This area for official notarial seal) Certificate of Occupancy _ uum OF�w Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78-820 CITRUS Use classification: S.F.D. Building Permit No.: 0110-284 Occupancy Group: R-3 Type of Construction: R-3 Land Use Zone: R -L Owner of Building: PIERRE& KATHRYN LETIELLIER Address: 81-101 INDIO BLVD STED-18 City, ST, ZIP: INDIO CA. 92201 By: G. SHOWALTER —�" Date: 04/08/04 Building Officia POST IN A CONSPICUOUS PLACE LU McGEE SURVEYING, INC. 73-301 Country Club Dr., Ste. 102 — Bermuda Dunes, CA 92201 Phone (760) 345-3828 — Fax (760) 772-5705 Friday, February 1, 2002 City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Re: Pad Certification — Lot 14, Tr. 24890-4 Pursuant to your request a field survey was conducted on the above referenced project to determine the vertical location of the building pad. The above mentioned was found as follows: LOT ADDRESS PAD (DES) PAD (FIELD) 14 .78-820CTTRUS 37.0' 37.1' 10 sugd } Payne rely Fro LS 5479 c ee R'' L.S. 5479 �v' C1Ty (�F LA W SEB 31 R� 1313111®e C11991 27 December 2001 The City of La Quinta Department of Building.and Safety 78-495.Calle Tampico La Quinta, CA 92253 V• Project: The Letellier Single Family Residence at: The Citrus 78-820 Citrus La Quinta, California Regarding: Truss Calculations CHARLES D. GARLAND Architecture, Interiors, Space and Land Planning Structural Calculations To Whom it May Concern, I have been supplied with truss calculations prepared by Trussworks of Thermal, California for the project noted above. Upon review of the truss calculations I find them to be in substantial conformance with the structural design intent as documented in the structural calculations prepared by my firm for the noted project. If you have any questions or comments regarding these issues or any other issue please do not hesitate in contact- ing my firm. i c rely, es arla d ' ' ` J/3 O� Architect EXP. ATC OF 74-854 Velie Way, Suite 5 ❑ Palm Desert, CA 92260 ❑ Phone: (760) 340.3528 ❑ Facsimile: (760) 340-3728 f; JUN, -20-2002 08:41 AM JOHN HACKER ASSOC. 760 321 5701 TITLE 24 REPORT Title 24 Report for: �1a2 Kathryn & Pierre Leterllier �l Lot 14�= 78=820 Citrus La-Quinta; CA v Project Designer: Report Prepared By:. Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: Date: 6/14102 The EnergyPro computer program has been used to perform the calculations summarized to this compliance report. This program has approval and Is authorized by the California Energy Commission for use with both the Reeldentlal and Nonrealdenilal 2001 Building Energy EMclency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5800. EneroyPro 3.1 By Energyftft Job Number. User Number: 2855 P.01 JUN -20-2002 08:41 1 r AM JOHN HACKER ASSOC. I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C-2R,Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary E2rgyPro 3.t By Energy$olt Job Number: 760 321' 5701 User 1 2 3 7 6 14 17 265S F.02 ........ ...__........ ..._........................................,l.,.,..__........,..-,._.... _, ..,- „ ._ .......__.... .- JUN -20-2002 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Kath�(n & Pierre Leterllier _ 6/14/02 Protect Tlde Date Lot 14 - 78-820 Citrus La Quinta Project Address Building Permit 0 Insu-Form Inc. (760) 324-0216_. Vion Check/.Date Oocumenlatlon Author Telephone Computer Performance 15 Field Check / Date_ Compliance Method (Package or Computer) Climate Zone enforcement Agene3r usie Only �o i r GENERAL INFORMATION Total Conditioned Floor Area: 4.453 f? Average Calling Height: ....... __..... 1 pr.Q ft Total Conditioned Slab Area: ____4.A53.f? Building Type: (check one or more) (ail Single Family Detached ❑ Addition �...� Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southwest) 225 deg, Floor Construction Type: [Z Slab Floor Number of Dwelling Units: ...... .... ....... too. Number of Stories: 1 ❑ Raised Floor Const. nent Frame Assembly Location/Comments Tvne I )_Vali,w (attic, oarane. tvDical, etc. Slab On Grade _ (tie 0,738 Covered Slab w/R-0.0 Perimeter Insulation Slab OnGrade We 0.756 Exposed Slab w/R-0.0 Perin' ler Inaulatlon _ . . __......._.,..._......_...._. ,......._ - ......_..._......_....._ R -2t Wall t`W.21.2x6.16) Wood _ 0,059 Exterior Wall R_3tl Roof (R.38.204.t8)Wood 0.028 Exterior Roof Solid Wood Door _ None 0.367 Exterior Door FENESTRATION 31hadling Devices Type Orientation _ Area Fenestration Exterior Overhang Side Fins SF) U -Factor SHGC Shading Yes / No Yes / No Front _ (Southwest) 22.5 ____.-_0,3!3. 0.36 Bun Screen ® ❑ ❑ Front (Southwest) SC,Q 0.62 0.36 Bug Screen (XI C._.I U RJ Front lwes.l).._._. _..._.. 40.0 0.55 __.Q,$.t3._........ ...... Buo Screen x❑ ❑ ❑ x❑ (Northwest) 94.0 ... ,,,,,,__, Q.30, 0.38 Bun ScreenX❑ ❑ ❑ Q Left (Northwest) _...., 20_l) 0.82 0.38 [Xi U U U Lcft._.._ (North) 112.7 __.J),�g„ 0.38 Bug Screen ® ❑ ❑ Rear (Northeast) _ 185_9 0.38 0.38 ED Rear (Northeast) „_. 120.0, 0.62 0.39 n ❑ ❑ X❑ skylight _—. _._ 0.88 0.67 __.. _ ❑ X❑ ❑ ❑X Rlght (South) .._ _28:0 .... .2B _2 0.87 0.55 _.__.None B4gScr®®n Q ❑ ❑ Q Richt (South) _ 11.7 0.36 0.38 ^__. Bug Screen O ❑ ❑ O Ri®ht (Soutneaslj _ 21.5 0.38 0.38 sun Screen X❑ ❑ ❑ X RunjnitAL1q Tlme: 08/14!0211:43:25 Run�da „t0340¢t Ener ro3.7 By Energy9on User Number: 2853 Job Number:Pe�e.3 of 19 JUN -20-2002 06:42 AM JOHN HACKER ASSOC. 760 321 5701 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Kathryn & Pierre._Leterllier Project Title 6/14/02 _ Date 1 820 Citrus La Quinta - Frame Poi Add e: Locafiorl/Comments Building Permit w I nsu_-Form Inc. r (760) 324-0216 Type Plan Cheek / Data Documentation Author Computer Pelfirmance _ Telephone 15 _ Field Check / Date Enforcement Agency Use Only Compliance Method (Package or Computer) _ Climate Zone GENERAL INFORMATION Total Conditioned Floor Area: 4.453 ftp Average Ceiling Helght:._._, 10.00 Total Conditioned Stab Area: 4,453f? Building Type: (check one or more) td l Single Family Detached ❑ Addition [� Single Family Attached ❑ Existing Building Multl-Famlly ❑ Existing Plus Addition Front Orientatiow. (Southwest) 225 deg_ Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: _..._r _.. _. 1 ❑ Raised Floor 3.1 By EnergySolt_ P. 04 Const. Component Frame Assembly Locafiorl/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION y _ Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins - (SF) U -Factor SHGC Shading Yes / No Yes I No Front (Southwest) _ 4Q.p - 0.55 0.65 _•• , _ Bug Screen ❑ ❑ X❑ Left (Northwest) _ 114.0 .ii,,82 0.39 __...,._B.Vti 6 ,MAn X❑ L,� �] X❑ Rear..___.(j earl 49.0 _ 0.92 ---- 0.38 19 g3,ween X❑ ❑ [,� Ix1 Rear (Eaet) „•,,._._22@.Q 0.92 0,39 .__..._ Bun Screen n o o X ❑ Rlahl (Southeast) . 13.8 Q,63........— 0.38 _ O.W9,6creen 7 0 1 R ❑ D ❑ ❑ -- -- ❑ ❑ ❑ U __.....__ D a ❑ ❑ --- F-1 E) F1 3.1 By EnergySolt_ P. 04 JUN -20-2002 08:43 AM JOHN HACKER ASSOC. 760 321 5701 P.05 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Kathryn & Pierre Leterllier ........... 6/14/02 Project Title Date HVAC SYSTEMS Note: Input Hydronie or Combined Hydronle data under water Heating 6ystente, except Design Meeting Load. Dlstributlon Heatingg Equipment Mlnlmum Type and Duct or Type (rumace, heat Efficiency Location Piping Thermostat Location / Pump, etc.) (AF UE/HSPF)(ducts. attic, etc.) R Value Type Comments Central.Fumace.._— Furnace__..._..-...._ 80% AFUE 1bucta�cLAttic....--_._._.__.... —_._4..2._ ._...__aCthack Livinn Zone Contra] Central Fumace 900 AFUE 80% AFUE_ DutiA In Atte 42 Aplhnck Livin_ eil� Ins FI=IN Cooling Equipment Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Spllt Air Conditioner 12 0 RFFR D felt In MI _ 42_.-.. ... ....... qpt ack,.-._,.- I Iutna 7nnw 6nft Ah Cnnr lions[._ ..-•- -1.2:0_SEEEL- L ,ietA In Atilt 42 Salhack LiYlnfllQltn0ylE11tr�_...._.._.. 8pllt Air Conditioner 12.0 SFFR nuctt In Atilt . ....._._Setback__v_,- MaaMr/9edmemR WATER HEATING SYSTEMS Rated 1 Tank Energy Facts External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O.SMI.TH Wgq,TER Small Gas Standard 2— 40 000 rn 0.95 nla n/A PRODUCTS fGSE-$0-2NF__ 1 For small ties storage (rated Inputs or less then or equal to 75,000 Btu/hr). electric resistance and heat pump water heaters. list energy factor. For large gas storage water heaters (rated Input of greater then 75,000 etumr). list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gee water healers. list Rated Input and Recovery Efficiency. REMARKS ` COMPLIANCE STATEMENT This cerufltate of compliance lista the building features and performance specifications needed to comply with Title 24, Pens 1 and 8 of the California Code of Regulations. and the administrative regulations to Implement them. This certificate has been signed by the Individual with overall design responsibility. When this certificate of compliance is submitted for a &Ingle building plan to be built In multiple orientations, any shading feature that Is varied is Indlceted In the Special Features/Remerke section. Designer or Owner (per Business 8 Professions Code) Documentation Author Name- Title/Firm: Address: Telephone: Lic. it: (signature) Enforcement Agency Name: Title/Firm: _ Address: Telephone` (date) Name: Title/Flrm: Insu-Form Inc. Address: 88255 Cora Rood __..-..._,,._.._.....___.. Cyathedret Clty, CA Telephone: (78o) 324-0219 _.......-.._._ Run Initiation Time: 08/14/02 11:43.jg„•_,..- ill..3.1 By Energyboft User Number. 2653 Job Number; Page:5 or 1& JUN -20-2002 08:43 AM JOHN"'HACKER-ASSOC. 760 321 5701 F.06 Certificate of Compliance: Residential (Addendum) CF -1 R Kathryn & Pie" Letedlier _ _ __6/14/02 Project Title Data Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified In this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justlficatlon, and may reject a building or design that otherwise compiles �.anu vn trio rruNquacy v" ono unu murUmunlairon suomrRUU. The HVAC System "Master/Bedrooms" must meet all CEC Crlterla for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERB rater must document the field verification and diagnostic testing of these measures on a form CF -4R. Field 3.l 9y enemysuft User Number: 2655 Job Number, Page:e of 18 'Mandatory Measures Checkllst: Residential MF -IR NOTE: Lowrlas residential buildings sub)ect to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compllanoe requirements listed on the Cerlillcate of Compliance. When this checklist is incorporated Into the permit documents, the features noted shall be considered by all parties as minimum component speciflestlons for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. DESCRIPTION Inatructlona: Check or Initial applicable boxes or enter NIA It not applicable. DESIGNER ENFORCEMEN Envelope Measures rBuilding 160(a): Mlnlmurn R -le Gelling Insulation In wood frame ease mbly, or equivalent U-valua. I 150(b): Loose fill insulallon manufaelurers labeled R -Value. X •g 1bO(c): Minimum R-13 wall Insulation In wood framed walls or equivalent U -value In metal home walls (does not apply to exterior masa wails) 160(d): Minimum R-13 raked floor Insulation In framed floors. $160(1): Slab edge Insulation • water absorption rete (a 0.3%. water vapor transmission rate co 2.0 permlinch. 0 §119: Insulation specified or Installed meets Inauletlon quality standards. Indicate type and form. X X116-17: Feneafreflon Pn2ducf6. Exterior Doors and Inf Hration/Ex9fration Contro)a 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leekape. 2. Fenestration products (except field fabricated) have label with carllfled U-Factcr, cenifled SHGC, and Infiltration certification. 3. Exterior doors and windows wealherelripped: all joints and penalrations caulked and seated. �150(g): Vapor barnsre mandatory In Climate Zones 14 and t9 only. 160(0: Special WItratlon barrier Inala)led to comply with Section 161 meets Comm)asion qua)Ily standards. �. §160(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory•bul" fireplaces have closable door#, outside air Intake with damper and control. and flue damper and control: , 2. Nq continuous burning gas pilots allowed. Space Condltioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheede and faucets canified by the Commission. © § 160(h): Heating and/or cooling loads calculated In accordance with ASHRAE, SMACNA or ACCA. r X §150(1): Setback thermostat on all applicable healing and/or cooling systems. X §150(j): Pipe and Tank Insulation --- 1. Storage gee water heaters with lase than 0.58 energy factor shall be externally wrapped with R-12. 2, First 5 feet of pipes closest to water haster tank, non -recirculating systema. Insulated (R•4 or greeter) 3. Beck -up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have 1.12 external insulation or R• 16 combined InlernalleLlemal Insulation. 4. All buried or exposed piping Insulated In rediculating aections of hot water Systeme. 5. Cooling syalanl piping below 55 degrees F. Insulated. 8. Piping insulating between heating source and indirect hot water tank. �(U§150(m): Ducts and Fans • 1, All ducts and plenums Installed, sealed and Insulated to meet the requirements of the 1899 CMC Sections 901, 903, 904 and Standard 8.3: ducts Insulated to a minimum Installed level of R-4.2 or enclosed In conditioned space. Opening# @hall be sealed with mastic, tape aerosol sealant or other duct- closure system that meate the applicable requirements of UL181. UL181A. or UL181B. 11 mastic or tape Is used to seal openings greater than 114 Inch, the combination of mastle Sold either meeh tape Of tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seems of duct systems and rhelr comporierim shall not be, sealed with cloth back rubbar adliesWs duct tapes unless such tape )6 used In combination with meetle and drawbonds, 2. Exhaust fans systema have back draft or automatic damper@. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. �/ X 4114: Pool and Spa Healing Systems and Equ)pmant 1, Certified with 78% thermal efficiency. on-off switch, weatherproof Instructions, no electric resistance heating, no pilot. 2. System Is Installed with at least 36" of pipe between filter and heater for future eater, cover for outdoor pools or apes. 3. Pool system has directional Inlets and a circulation pump time switch. 115: Gas Bred central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously buming pilot light. (Exception: Non-eleclrical cooking appliances with pilot < 130 Btu/hr) Lighting Measures C)(] § 1501k)l: Luminaires for general lighting In kitchens shall have lamps with an efficacy 40 lumenslwatl or greater for general lighting In kitchens. TNs general lighting shell be controlled by a Switch on a readily accessible lighting control panel at an enlrance to the kitchen. X I50(k)2: Rooms with a shower or bathtub must nave either at least one luminelre with lamps with an efficacy of 40 lumen0watl or greeter switched of the entrance to the room or one of the alternative to this requirement allowed In Section 1 SO(k)2,; and recessed ceiling fixtures are IC (Insulation cover) approved. EneegyPro 3. f By EnergySoR User Number: 2866 Job Number,. PaQe_7 Of to ASSOC. Computer Method Summary (Part 1 of 3) C -2R -Satter n & ?ierreleteriligr _ 6114/02 _ Protect tie D 19 Int ro sc14 t Address -7R-R2Q CitnIA 9 menta lnsu-Fnrm Inc. _ (760) 324-0216 Documentation Author Telephone Cn�l e Em M h rmancec— Building Is mit solar Gains an Vheck/Det Source Energy Use Nld h�cklData Proposed omp soca et 0 ac age or omputer) solar Gains Climate one Source Energy Use Standard Proposed Compliance (kBtu/si-yrs Design Design Margin Space Heating 8.74 9.46 -0,72 Space Cooling 43.33 40.85 2.48 Dwmestic Not water 6.40 6.38 0.02 Conditioned Floor Area: 4,453 Floor Construction Type: X� Slab Floor Building Type: Single Fam Detached U Raised Floor Building Front Orientation: (Southwest) 225 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 44,530 Number of Stories: 1 Slab Floor Area: 4,453 BUILDING ZONE INFORMATION M of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt, Area l lying 7nnn.._..........-- ----•......1..312 13 190 A 29_ _ r ndJtloned_.— Aalhark _.2 _n/a Living/r) nU*Entry,...-- ---1.397. ._.t,397. 13,920 0.11 rnM Boned--.__ Rethaek _ 2 n/a --1,74.4. --17-490 n719 — alpp^tng .............. SleeplpgStat_ —�2 �lE OPAQUE SURFACES Act. solar Gains Type Area U -Val. Azm. Tilt Y / N 0_Q59 _22S... ........ .9A W.Mi— 20 —._0.059.. 270 an Wall __._..ze q O5g 315 �n 0 059 0 —....80. mall... _-----73 — 1 OAA 43.._...: _90 nMAI 1vS _..-...._.Q. WAI .... ... ...... ... _......0 0 059 190 ..._......90 - Wall .---... ... -.0- A (I59 315 on. nnnr ........... .4A- n 382 313 —9n. Wall. —... ........ --It o ns9 4A _.._...._90. _wall...........— 96 0 t159 Roof ...... 1.381 bn2A _—.133. Wall.— 21n n 059- ,....225. an Wail.— 19R (1.059, . ,,,.315. �n WaJL— AM 11.059. !Z �0_ well..-.-_ 101 n ns9 .__.....9.0..�Q Wall......_. toe n n,%9 X35, Rnof. .. 1 734 n MR 19g..,........_Q Form 3 Reference R-21 Wall (W 2t2xB.1,8). x6.18) R-21 Wall (W 21 2x8.18) _.. R-21 Wall 1 2x81fl1.._.._..,..... --- R-21 Wan (W 21 2xR R-311 Rant (R AR 2x14 R-21 Walt NN 21 2xR_1R) ., R-21 Wall fW 21 2x6 191) Selld Wand nnnr R-21 Wall (W 21.2x8 1A)...._.._ ,-...-•-- R-21 Wall 21 -- R -AR Soof (R 3A B-21 WalLJW-2t.29111, 1 R-91 Wa11.(W.2.1..24 61 .E2.1..WA11,(W.21.,2xAIi R-21 Wall j1U21.24,1-B) R-21 wan (W 21 2x6..1.6)......_ R_1111 Rnnf (R11i 2)fL4.•,1B). Location / Comments Wrong Zone Llving 7nnw Moll lona .._..._........_._-- t lyna Zone.__— .LlWng-Zane _ Ltulr4 Zone.._. I lJ&g1nlrJng/Entry_,_, Iving/nlnlnn/Entry 1 lvinMrllnl ogLEnlry....._..._.._.—. 1bdnWD1nA41Entyy. Lldpg(Dlning/Entry .1-tving(AINn_/E�n MantarlARrlmnm_a Ma,ktar1RPdrnnm_Q _ MaalarJRPA/nnm% Mawtar1RAnrnnma .Mael8f1AAdmnm1t ,Maatar@3Admnmv ....... _ R.Nri.,(�ItlatlonTlme: 08/14/0211:43:25 --Q)l�code: 1024001406 Energ Pro3.1 ay EnergySoR User Number: 2655 Job Number: Page:a of 19 JUN -20-2002 08:45 AM JOHN HACKER ASSOC. 760 321 5701 P.09 / Computer Method Summary (Part 2 of 3) C -2R Kathryn & Pierre Leterlligr _ 6/14/02 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Locatlon( # Type Area Factor SHGC AZm. Tilt Comments _L_, ttlf)ndaa Frent (-nurhwAgt) 7217 0 nan ,___0 %A ??S �90 LAMLEAlum Wlndewn t_Wag arms 2 Window Front (Soulhweal) 2040 0.620 --..= . ..... -72.5. 9Q Qq.F,Alum. Windows Livina Zone Window Front (West) 40.0 ��,gQ,• ,.•„•• •,0;�,5 ._.....27.0 90 low E Alum. Windows Living Zone 4 Window Left (Northwest) . 72.5, ,_..Q3¢� _ 0_36 . 90 Low E Alum. Windows Llvino Zone Window Left (Nodhweet) 20.0.. .. Q 020. _..._�0-39 _,•,__318 315 90 Low E Alum. Windows Llvina Zone 6 Window Left (North) 35.9 X360.. _...;_...0,36, 0. -_QQ• LQw�.Alum, Windows Llvina Zone - 7.- W..indui Lett (Northl 11.0 0396 038 - 0 -_-90 Law.F-AL .Wipd0.wQ-__,.._....._.. AjAckg.ZGna....._..._...__._......_. A- Window Rear (Northeast) 24.4 0.380 -_ 0.38 45 90 Low E_Alum, Windows• . . Living Zone__ _•• 2_ Window RAer (Nnrtheaat) ........ 7,5,_,__......_....._ 45_ _-M l,Qw E Alum. Windows Living Zone In Window Rear _(Nncthaeat) _.44 Q. 0,620 0.39 �3 � Law E Alum- Windows Living Zone ..0 Wndow, _.Rea!_(Nprtheaat) 1e.6 0.360 0.38 4_ 90 Low E Alum. Wlndows Living Zone ' 12 Window Rear (Northeast) 15.0 0.380 0.36 45 _ 00 Low E Alum. Windows _ Liyi g Zone -j3 k4oht Right tseuthaast) 2 n 0 690 ._...._..0.6.7 133 ..-.._0 L )w.E.AJjAai:_IN.haQwA 14 Window Rloht (South) 29.2. ._,.0,5.70.. .._...,A.,S.�. .,....,18Q„ -__90 Double NonMU Tinted Default Llving/Dlnina/EMry__-• 15, Window Right (South) 11.7 0.36p -__Q3@. ._-�0_....... 89.L�OYr.J~_Al4i?4fflrjI4.ril­_. ..l lrlgplQiniOgLEnUy_.__.__,._....._ 18 Window__ Left (Northwest) 12.0 0.380 0.38 313 �Q Latx E Alum,�-�1(jnQgyyg-,__,,,,_,•,_,• .Llyng Dini End _ ..1.7.. Windo-w... Rim _...... (Northeasl) 91.0 0.380 0.38 45 90 Low E Alum. Wlndows Llvina/Dlnlna/Entry -U Wind w._._Rttef.:....(tlPrtheeel) 42.0 0.360 0.36 45 90 Low E Alum. Windows LlAna/Dlning/Entry Al Wind- _RAW---.--(NOrtI30.00 S6.0 0.620 0-39 45 --M Lew F Alum- Wlndewa LI Dlning(Enta 20 Window._..Rl9�t_,�Southeaat) 10.0 0.360 0.36 135 90 Low E Alum, Windows Llvina/Dlning/Entry 21 Window Right (Southeast) 4.0 0.360 0.36 135 90 Low E Alum. Windows LivInalDlning/Entry 22, Wlndow Right (, oulheael) 7.5 0.360 _.,,..8-0 0*E.Atum 23 SWiahl Right (Southeast) _,_• 16 0. •, ,0:680 -_---_0.38. 0.67 ...-_-1.33.. 135 .VIlidoyys......._�_._. 0 Low E Alum. Windows Llving/Olning/Entry 2 Wlndow Front (, outh,Wgsl) 40:0. 0.350 0.65 _ 225 90 Low E Alum. Wlndowa Master/Badrooma 25 Window Front _�Qythyv@et) 30,0 0.620 0.36 225 90 Low E Alum. Wlndows Master/Bedrooms 26 Window Left „-1Nonhweat) _ 0.360 0.36 315 90 Low E Alum. Windows MesterlBedroome 77 Window Left(Northwest) - - - -- .. -2.0 _ 25.0 0.360 0.36 315 90 Low E Alum. Windows Master/Bedrooma 7g Window Left__.,. (Northwest) 10.0 0.380 0.38 315 90 Low E Alum. Windows Master/Bedrooms TR Window Left (Northweat) e4.0 0.820 0.39 315 90 Low E Alum. Windows Meater/aedrooma INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Fin # Exterior Shade Type SHOC Hgt. Wd. Len. Hill. LExt. RExt. Olst. Len. `Right Mgt. Dist. Lon. Hgl. i Bug Screen -. 0.795; 0 4.5 0.1 8.0 8.0 „-. 2 Bua Screen _ 0.78 4;0 5 0 _8.0 _ 140 0_1 14.0 14.0 _ 3 Bug Screen - - 0.76 8.0 2.5 B.Q 0.1 8.0 8.0 4 Bug Screen 0.7 _ 6 Bug Screen 0.78 4.0 _U 6 Bun Screen 0.78 _.55 .-,-5,5 3.0 0:1 .__3.0 .._3..Q --• -- -__.... ..--.... sun screenO.1 3.0 3.0 .._.._._. 8 Bun Screen__..._.. 0.78 8.5 3.9 3.0 0.1 3.0 3.0 ........_ _ 8„-. Bug screen 0.78 2.0 3.9 3.0 0.1 3.0 3.0 -_ 10 _ Bug.Screen 0.78 8.0 8.0 8.0 0.1 8.0 8.011 Sug,Syreen 0.76 2.0 8.0 8.0 0.1 8.0 8.0 12 - Bug -Screen . _ 0.78 5.0 3.0 3.0 0.1 3.0 3.0 - _ - - 13 None --_ 1.00 14 Bug Screen _ 0.76 5.0 5.9 12.0 0.t 12.0 12.0 -„_,_„• _,___., 15 Bug Screen - 0.78 2.0 5.9 12.0 -- 0.1 12.0 12.0 16 Bug Screen F 0.76 2.0 8.0 14.0 0.1 14.0 14.0 17 Bug Screen 0.76 6.5 _ 7.0 10.0 ..._ _0,1 10.0 10.0 ,•,_, Ta Bug Screen 0.76 2.0 7.0 10.0 _, 0.1 10.0 10.0 19 Buq Screen 0.76 8.0 7.0 10.0 0.1 10.0 10.0 _ 20 Bug Screen 0.78 5.0 2.0 10.0 _ 0.1 10.0 10.0 - - 21 Bug Screen -- .... 0.78. 2.0 ........, 2.0 .._..3.. 10.0 _._.....- 0.1 10.0 10.0- ....,,-0- _........ 22 Bun Screen 0.79 2_6 3.0 �......, 14.0 ............ 0.1 14.0 14.0 ,_,,,,. 23 None 1.00 - - 24 Bug Screen _ - 0.76 8.0 6.0 8.0 0.1 8.0 8.0- 25. RyA Screen 0.76 5.0 6.0 3.0 0.1 3.0 3.0- 28 Bug Screen 0.76 2,0 1.0 8.0 0.1 8.0 8.0 - 47 Bug Screen 0.76 5.0 5.0 8.0 0.1 8.0 8.0- 28 Bug Screen 0.76 2.0 5.0 8.0 0 , 8._0 6.0 - _ 29 Bug Screen 0.76 8.0 8.0 8.0 0.1 8.0 8.0 -.1 - EnergvPro 3.1 E Number: 2866 --Job Number. .. ....... ..............._.................-..__........_..... -._ - ......... .. ...... - ..... ...,1-r JUN -20-2002 08:46 AM JOHN HACKER ASSOC. Computer Method Summary (Part 2 of 3) C -2R Kath n & Pierre Leterllier Project Title Date 6/14/02 FENESTRATION SURFACES U- Act. Glazing Type Location/ Type Area Factor SHGC Azm. Tilt Comments 3D Wlndnw I AN (NnAhwegt) 1s ee n'g_ nag _4,t5_ 2Q 1 nw F Alum WlndnwA MAe1Af/$ArJo0M1k 31 Window Lem grthweal) 6.6 0.360 0.38 315 -90 Low E Alum, Windows __ Maatarl8edrooma �U Windoyv Leh (NpO _.., B0.4 0.3ti0. 0.36 0 _$Q, Law E Alum. WjnQpwa _ [vlaater/Bedrooms 33 Wln W Le (Nom _15.5 0.380, 0.36 0 _90 �qw E Alum. Wing"s _ .MRteter/Bedroome ;}4 Window._. Rear (EgsIZ _.._.90.0 0.820 0.38 90 Lqw E Alum. Windows Nlaater/Bedrooms ._._ _2.� b(jpdow Rear ._1Eo ). ____64,Q 0.620 0.39 ....,90 �0. LQw E Alum. Wlpdowe Matster/Betlrooma___ M Wbdow Rear_ (Egst� b4.0 0 82Q 0 3g �jL -�0 l ow E Alum Wj��wa Mflater/Bedrooms .. _•,•, 37 Window Rear • _ East 9.0 _0_620 0.36 90 _90 Low E Alum, Windows Master/Bedrooms _ fl IDltndow Rlaht _.CSS2Wtieasq 7.5 820 --JLX ...._135 t x tUa Wln,02wa (�aetedeedrooms �fl W.inc�w Rlaht_._ C gabq 6.3 g2Q_ IA _ 1311 _20 Low E Alum Wlrtdnws , _MgniedBedraams AQ Skylight Riaht_. _($Qyt[tQgsl) 10.0 _.0,89Q 0.67.. 135 ___..Q LowEAtum_.Wlgdowe __ .Mneter/Bediooma,__ INTERIOR AND EXTERIOR SHADING Window Oy_erhanA Left Fin,. Right Fin •, Exterior Shad8�T pe _„_SHGC 1Nd. Len. Hgl. LExt. RExt. Dist: Len. Hgl. Len. Hpt. 30 .. Bu Screen ... 0.76 _•_Hyt. 2.0 8.0 _ 8.0 0.1 8.0 8.0- _Dist. 3t Bua Screen 0.70 8.5 1.0 8.0 0.1 8.0 8.0 ,__ 32 Bua Screen_ _....• 0.76 6.5 7.9 _ _ 3.0 0.1 3_0 3.0- .•._ _ 33 �..V _ 3.0 1 3.0 3.0 --... - 34 Bug Screen -..._0.76 s.0 ._ 8.0 2.0 ___9_1- 35. qua Screen _....._ _ 0.78 __U _.B D _.,2 D 0.1- 38 Bun Screen...- - 0.78 �Q 8.0 6.0 _�.t __6.0 8.0 -... --.... - 37 Bug Screen _ 0.76 3.0 3.0 2.0 0.1 2.0 2.0 38 Bun Screen ,.. 0.76 2.5 3.0 2.0 0.1 .-,-2-D 2.0 _ „•_ 39 Bua Screen _ 0.78 2.9 2;5 _ _„- 2.0 1 2.0 2.0 _ 40 None 1.00 - _ Rup„jnitletlen Tlme:_.A8/14/02 1t:49:25_ Run Code:�,1Q2d051e06 ~•• EnergyPro 3.1 By Energy6oh Deer NumOe_rµ2GS5 JoD Numpei: _ Psg�:10 of 1Q _ JUN -20-2002 08:47 AM JOHN HACKER ASSOC. 760 321 5701 R.11 Comouter Method Summary (Part 3 of 311 C -2R Kathryn & Pierre Leterllier _ 02 — Project title Data THERMAL MASS FOR HIGH MASS DESIGN Area Thick, Heat Inside Location (at) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Type F2 Length Factor Insulation R -Val._ Depth Location / Comments _ Slab parime r is o.7a _D.Q— Location / Comments Slap panme 8L -- n JIM 11.0 0 JIvIpa2nne , .5180 .149 afar _lo -0,.7.4 ._Aft — n UVinQ/D1n'nQ'FntrJ_.. Slab.P.erlmAter —5 _0.,76 0 Imng0ninglaky... _ Slab.P..edmwPr M -0.:7o. n Magid andm^ma MVAC SYSTEMS Meeting Equipment Minimum Distribution Type Duct Type (furnace, heat Efficiency and Location Duct Thermostat Location / Comments pump etc.) _ _ _ (AFUE/HSPFXducts/attic, etc.) _.R -Value Type SEER attic, etc,) 80°/ AFUE Ducts In Attic _.. ._.,4.2..... Setback Living ....___ Central Furnace .... ...... 80%AFUE Ducts In Attic 4Y._. Setback Llvinrt/Dlning(Entry Central,F.urnara— 80%AFUE Ducts in Attic 4.2..,_. Setback Mester/Bedrooms... ...... Hydronic Piping System• Name.... Pipe Pipe Insul. Length _ Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. coal ng), ----.�L._—_�.�._L_ SEER attic, etc,) R -Value Type Comments _. - -_- _. BpllIAir �Conditioner 12.0S1FE$ DuctslnAttic 4.2 $r9tbetk..,.....___ L1vIn02ene . Spilt Air Condilloner 12.0 SEER Duds In Attic —4.2— Llving Nning/F_ntry Split Alf Conditioner 12.0 SEE Ducts In Attic 4.2 Setback ,M.eater/Aedmoms WATER HEATING SYSTEMS Rated' • Tank Energy Fact! Tank Insul. Water Heater Water Heater Distribution 0 in Input Cap. or Recovery Standby R -Value System Name - _..._Type Type _--, syst; _(6tulhr)_ {gal) Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS.... FOSE=S'0=230E Sf1191.1_Ges_._._....tenderd_._...........,... :_.2..,._ ._•,.....4.0,0.OQ....... -...... n R5 n/a n/a For small gas storage (rated Input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input :- 75000 Btu/hr), Ilst Rated Input, Recovery Etflclency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. JUN -20-2002 08:48 AM JOHN HACKER ASSOC. 760"321'5701 P.12 Comauter Method Summary (Part 3 of 3) C -2R Kathryn & Pierre Leterllier _ 6/14/02 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick, Heat Inside Location Tyrpe _ _ Aso (In.) Cap. Cond, Form 3 Reference R -Val._ Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location /Comments Slab.P.erimeter • -- .....290 0.79 o_e ,.._,_Q Meter/Bedreems MVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPFXducts/attic, etc.) R.Velue Type Comments Hydronic Piping pipe Pipe Insul. .System Name _ Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat hest pump, evap. cooling) (SEER) (attic, etc, R -Value Type Location / Comments WATER HEATING SYSTEMS Rated' Tank Energy Fact' 1 Tank Insul. Water Heater Water Heater Distribution # In Input Cap, or Recovery Standby R -Value stem Name Type _ Type _ Sxst. (Btu/hr) (gal) EHlclenc�.._,,,. Loss r%� Ext. 1 For small gas storage (rated input — 75000 Btuthr), electric resistance and heat pump water heaters, list energy rector. For targe gas storage water heaters (rated Input > 75000 Stu/hr), list Rated Input, Recovery Efficiency and Standby Lose. For Instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARK$ _ _ Run IOIRlpjjpn Tlme: 08/14/02 11:45:23 _.RtULC4de: 1024051405 Ene io 31._ 8y F !gySoft User Number. 2655 Job Number:PaQe:12 of 19 _._„ JUN -20-2002 08:48 AM JOHN'HACKER ASSOC. ' 760'321 5701 Computer Method Summary. (Addendum) C -2R –Ka1bry—n&-2JQLre Leterllier 6/14/02 Project Title pate Special Features and Modeling Assumptlons The local enforcement agency should pay special attention to the Items specified In this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan The HVAC System "Master/Bedrooms" must meet all CEC Criteria for a tonally Controlled system servinp only Sleepinp Area HERS Required Verification These features must be confirmed andfor tested by a certified HERS rater under the supervision of a CEC approved HERR ,3 .1 By EnergySaft User Number: 2865 Job Number: _ Pde9.13 of 19 JUN -20-2002 08:49 AM HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Kathryn § Pierre Leterllier DgTt: 6/14/02 eYBTEM NAME Living Zone FLOOR AREA 1 312 ENQNEERINGH 4YATEM LOAD _ Number of Systems , Heating System COIL CFM C OLINO Sensible PEAK lIL Latent CFM HTO. PEAK Senslble 25.71 13,128 0 482 19.573 Output per System - 89,000 Total Output (Stuh) 89,000 Total Room Loads 1.553 Return Vented Lighting 1,288 0 Output (Stuh/sgit) 67.8 Return Air Ducts Return Fan 979 Cooling System 0 Output per System - 58,000 VentllatlOn0 0 0 Total Output (dtuh) 58,000 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 0 3,128 0 Total Output (Tons) 4.8 -Tots) Output (Bluh/sgft) 44'2 11286 979 I 21,530 28 282 Total Output (sgfVTon) 271.4 Air System HYAC EQUIPMENT SELECTION - CFM per System 2,055 Alrflow (cfm) 2,055 •-- _ - ••-• ,000 - - BDP CO. 963AND60-A 38,598 16,768 ff— -•,,. -. Total Adjusted System Output (� 38,598 16,768 C 89,000 (Adjusted for Peak Oeelpn Conditions) I _ TIME OF SYSTEM PEAK Aug 2 pm Jan 12 em Alrflow(~egft) 1.57 Alrflow (cbrffon) 425.2 Outside Air (S6) 0.0 outelde Air (cflm/sgR) 0.00 Notes values above glven at ARI condition& _ EATING SYSTEM PSYCHOMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.6 OF 69.6 OF Outside Air 110.0 OF Supply Alr Ducts 0 Cm Supply Fan Hooting Coll 100.0 of 2055 cfm ROOM 70.0 OF 69.6 of Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Tem aratures at Time of Cooling Peak 111.0 / 77.4 OF 70.6 166.8 of 73.6 166.8"F62 -D/ 60.9 OF Supply Air Ducts Oulelde Air 0 Cfm Supply Fan 2088 cfm Cooling Coil 62.6/61.10F 56.0% R.M. ROOM 78.6 1 66.8 OF 18.0 / 86.(3 of Return Air Ducts I EnerpyPm 3.1 By Ensrtiy8ofl - User Number: 2855 —.._ Job Number — ._. Page:1♦ of t� JUN -20-2002 08:49 AM JOHN HACKER ASSOC. 760 321 5701 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY rROJECT NAME . DATE Kathryn & Plerre Leterl Her 6/14/02 SYSTEM NAME FLOOR AREA Livin�c //Dlnln /Ent 1-397 Number of Systems 1 _ HeatinR System Output per System 88.000 Total Output (Btuh) 89,000 Output (Btuhlsgft) 63,7 Cooling System Output per System - Total Output (Bluh) M 58,000 x58,000 Total Output (Tons) Total Output (Stuhlagft) Total Output (agftlTon) Air 3 stem CFM per System 4.8 41.5 289.0 2,066 Airflow (cfmi 2,055 Alrflo_w (cfmisgft) 1.47 Airflow (ctmrron) w 425.2 Outside Air 1%) 0.0 Outside Air (0m/sgft) 0.00 ote: values above given at ARI condltlons ;ATINO SYSTEM PSYCHROMETRICS 28.0 OF 69.5°F 69.5 OF Outside Alr 0 dm Supply Fen 2055 cfm 69.5 OF DOLING 9 1111.0 / 77,4 UF Outslde Air 0 cfm 78.6 / 66.9 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG._PEAK CFM Sensible CFM BensiblIatent 1,88 27,894 3,33 475 20,114 0 1,385 1,008 0 0 0 0 1,385 1,008 30.4531 3.33 BDP CO. 563AN080-A 38,513 18.938 89,000 Total Adjusted System Output 38.513 18,938 89,000 (Adiustea (or Peak Design conaioone) TIME OF SYSTEM PEAK Aug2 om Jan 12.8 109.9 of Healing Coll to Return Air Ducts `S 70.6 168.9 of 76.6 166.90F 62.1 161.0 of Supply Fan Cooling Coll 2055 cfm Supply Alr Ducts 100.5 OF R— M 70.0 of Supply Air Ducts 82.7 181.2 OF 55.9% R.M. R��NIS 78.01 66.7 of I b Return Air Ducts LFmrgyPro 3.1 By Energy3ofl Ueer Number. 2656 — —,� �^ Job Number: Pepe:16 of 1g JUN-20-20bY VIC$;J0 kill JUHN HHI;KtK i-rSjV�;, fbM o'Ll Jfbl r✓ . 1 o HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY -J PROJECT NAMC DATE Kathryn & Pierre Leteriiier 6/14/02 SVBTEM NAME FLOOR AREA Master/Bedrooms 1.744 Number of S stems 2 "eating System CFM Output per System 58.000 Total Output (Stuh) 112,000 Output (Stuhlsgft) 64.2 Cooling System Output per system Total Output (Stuh) 40,000 80,000 Total Output (Tone) 6.7 Total Output (Bluhlsgft) _ TOW Output (sgtt/Ton) 45.9 281.6 Alr 9 tem CFM per System 1,395 Airflow (chn) 2.790 Airflow (cbnlegft) 1.60 Alrflow (cfmfton) 418.5 Outside Air (%) Outside Air (cfm/egft) 0.00 ote: values above gavan at ARI conditions 'ATING SYSTEM PSYCMROMETRICS 28.0 OP 68.5 OF 68.5 OF Outeld, Alr 0 cfm 88.5 OF 111.0 / 77.4 OF 311 Outside Air 0 Orn 78.7 186.5 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CO LING' PEAK C IL HTG. PEAK CFM I Sensible Latent CFM Sensible L 441 F. 415 �8.,;7 BDP CO.563AN042-A 51,629 21,576 112,000 Total Adjusted System Output 51,629 21,575 112,000 (Adjusted for PeaK Deelgn Conditions) 108.00F Supply Fen Heating Coll 2790 cfm TIME OF SYSTEM PEAK _ Aug 2 pm C_Jan 12 em )% Return Air Ducts 4 78.7 / G6.5 OF 78.7 / 68. S OF = 81.4 / 60.3 OF Supply Fen Cooling Coll 2790 cfm Supply Air Ducts 104.5 OF R OMS 70.0 OF i Supply Air Ducts 82.1 / 60.5 OF 54.4% R.H., ROOMS 76.0 166.3 OF Return Air Ducts EnergyPro 3.1 Sy ftefjjS User Number: 2655 Job Number. Pa8e:18 of 16 JUN -20-2002 08:51 AM JOHN HACKER ASSOC. 760 321 5701 P.17 FROOM LOAD SUMMARY PROJECT NAME Kathryn & Pierre Leterllier QATE 6/14/02 eye EM NAME FLOOR AREA Llvin Zone 1312 _,. ,_90E NAMEROOM Living Zone - - - - NAME Femlly/KIVNook -.- Mult. t ROO CFM 1,533 _ 0 COOLING N®ISLE 25,771 PEAK LATENT 3,128 COIL CP M 1 553 -.,., COOLING N�81BLE 23,711 PEN( ATENT „3128 COIL F 482 NTG. PEAK 8EN IBL 19573 PAGE TOTAL 1,633_ 2x,711 x,128 TOTAL 1,553 ^ 25,711 3,128 L4 22 ,,,.. 19,573 482 19,573, CEne,gy ,o 3.1 By Energy$ofl ^ User Number: 2055 Job Number: w Page: of 10 JUN-20-2002 08:51 AM JOHN HACKER ASSOC. ROOM LOAD SUMMARY PROJEC NT AME �- ___ Kathryn 8 Pierre Leterlller 760 321 5701 P.18 DATE 6/14/02_ FLOOR AREA 1,397 JUN -20-2002 08:52 AM JOHN HACKER ASSOC. 760 321.5701 P.19 IonnM I nen RlIMMARY