Loading...
0008-178 (SFD)cV ; W pt'7 �-) 4t- 0 c 1 LU o Z CD O O W W I— a N Z M LO N ON U °) C Q Z Lo W Q 0 X W ED U U O CL rn ,�t Z_ co 5 �0 Q J LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 740145 110 ClIn W Date b2-01 c- Signature of Contractor F OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property; am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided •for, by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. VSI have and will maintain workers' compensation insurance, as required by S2 tion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. FA014 PACIFIC 04,11 WOMB?, (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation,provisions)of/Section 3700 of the Labor Code, I shall forthwith comply with thosebrovisions. Date: Applicant �f �a .//"%.,/ A %r "� Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer.to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for, a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at ,. whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorise representati es of this City to enter upon the above-mentioned property,for` ip%pection puriloses. ignature (Owner/Agent j� A�%� • �'' �A �• Date Ln<'_ -- aj �i a• g BUILDING PERMIT PERMIT# DATE VALUATION LOT TRACT JOB SITE APN ADDRESS M-930 &�''F .' TIN ' 777) 101.4W OWNER CONTRACTOR DESIGNER /EN 1NNEER 4AS}X. PAA ryC H0.==VnnR4u bAPrf-l✓ tXvLRC TOM33RX" " ?.) � A —111 JUS. BLVD. 02,010 4100 MAC ARM UR MVD QW, k��N;i !OR.'1; BRACH CA 92660, 1.^�%T€9.'.i:rlit-r'.0-1 CLQ -02660 . (945?)622.8400 CML 4. 1509 USE OF PERMIT Il�YC91:.1�' :�`.��i•5...'�' ,1:'r"t�!'.+'�L ��f;J tiF D . PEANUT DOES 1400 INCJ.il02 MOC Y WE3i..f,1PODUAPP?RGAC H - Ie f..Y!MM CONSTRUCTION 4497,00 h)1' P09CH)P.AT10 'C72.0 P 0ARAdlMftR1~'O1^ !' (18F) 19,6mno P MI M NUMMARY C'014S'fl IR.,"31014 FES. 101.000418-000 $11626.$0 Ip•.',((Ary9a���(1Q}t�pyi'•'�zCK FEX 1.01 -MM -439-3119 $1-109m ¢17 S314'r 101 -000 -4 -12;9 -IMS _Moo NS!'.CWAt+ ICA L FIS 101-000-421-000 11.34.00 E1.EC'I'Iz.:fYAL PEP 101.000.420.000 5243,44 PL.UMB1110 FM 101-000-419-000 $211,00 ::'1'RONOi.1O7'IOW FEE RESID 101.000-:241=000 170. t4 101-(1(.042S-000 INl'Stt. {Cf��1gqt��.yP��..1 `$.30,}00 ,yy��e.1:gY�Yi �ry �+'�y�y} Q •-.EJ.L'SV �1,1��IS".L'.1.i. {!A[l 0.'AA1..'7 S°.IM 1, q. �I•b7'AF. V"W .A.>tt.`d 1N"1 VUI?`f C PIAr.:I`,5.. IkFZk,)41-OD 0-2511 Y0 $453.41 am, ci tc�;6;JA3o".C1�,t:fi+:"'i�O��1`,iep��1i�:15i�.�T�."%3�.a'",x `�5,9`,,' ,30 � `• 1,x,33 T �E`x � 2 4750,00 RECEIPT DATE BY DATE FINALED INSPECTOR ti m 4 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs 3�: : • Underground Ducts Forms & Footings Ducts Slab Grade f Return Air Steel -Combustion Air Roof Deck Exhaust Fans O.K. to Wrap%,�a ( Framing �( :�l / <+� F.A.U. _ Compressor 1=7-r Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wali Firewall - Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Plumbing Final Water Piping Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Encapsulation _ _ _ Sewer Connection ��v Z� Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit . Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors .Temp. Use of Power 'i;4 Al Final Utility Notice (Perm) I -w I L -0-r. 3 0 YOF LA QUINTA SAFETY DEPARTMENT 01 777-7012 ECTION REQUEST LINE 777.7153 �� CAPI -L PACIFIC HOMES INC. Contra ctorCA AL PACIFIC HOMES INC. Permit Number POST ON JOB IN CONSPICUOUS PLACE f:. INSPECTOR MUST SIGN ALL APPLICABLE SPACES S1l'U-t' NIM WAI.,L/I'OOL/DRIVEWAY APPROACH TYPE OF INSPECTION DATE INSP., ' FOUNDATION & SETBACK FOOTING STEEL MAIN GROUND SYSTEM GROUND PLUMBING PRE-GUNITE DO NOT POUR rONCRETE UNTIL ALL ABOVE HAS BEEN 1 NED CONCRETE SLAB / !.,'•� JOISTS & GIRDERS ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED ROUGH ELECTRIC ROUGH PLUMBING ROUGH GAS & GAS TEST HEATING & VENT • A/C 1 FIREPLACE ROOF BOND BEAM "... O.K. TO WRAP l ! GROUT O 4' O 8' FRAMING INSULATION '�-�c i I PRE -ROOF COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED DRYWALL INTERIOR (; EXTERIOR LATH j POOL PRE PLASTER ` P OO L ENCE & GATE _ (SEWER SEPTIC TANK !) %T, ti FINALS ELECTRICAL PLUMBING FI NAL GAS TEST f (T C? HEATING • A/C HOUSE NUMBERS JOB COMPLETED i t t TEMP POWER ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTP.ITIFS C19 aCCt.)PY BUILDING Certificate of Occupancy City of La Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS: Use Classification: SFD Occupancy Group: R3 Type of Construction: Owner of Building: CAPITAL PACIFIC HOMES INC Building Official 78-930 CITRUS Bldg. Permit No.: 0008-178 Land Use Zone: RL Address: 4100 MAC ARTHUR BLVD #200 City: NEWPORT BEACH CA 92660 By: KIRK KIRKLAND Date: 6-13-01 POST IN A CONSPICUOUS PLACE t Building Address Owner T4ht 4 4 u&& P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 C, ,a,-rAL. 1tT.c I�iL t1�r-1Er. INC Mailing Address City Zip Tel. C DP 0"A, l-► _= `ag l Cj Oq - 479 .0-11#-7 Contractor -J _f.C. MG -r -Ifni itic_ Address Fpm t4- cx AIr ST I D I City Zip Tel. ('C. ? . - Ir 4 -IDI, cid, ai=r d L, Lit State Lic. City & Classif. ) LI 0-7 Lic. # Arch., Engr., Designer Y tic Address S?- f :� Tel. City Zip State r • �. 1 a . J , -r :T C -1 ,) Lic. # r^ - Ci 17-r LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of; the Business and Professions Code, and my license is in full force and effect. L,-7 au SIGNATURE J, s'. _ DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Susiness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to ,8s issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). 1I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Butsness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) f 1 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and. who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1? 1 am exempt under Sec. 8. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company f7 Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation orless.) 1 certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: Ir, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of aOplicant —Date— Mailing ateMailing Address City, State, Zip BUILDING: TYPE'CONST. V OCC. GRP. A.P. Number Legal Description Project Description Ni�J /71tJUL.E �w !� 3 L) I f ; ✓`;�. Ll�r�.A TiQ6� �9 U '--Lf' S , Minimum Setback Distances: Sq. Ft. Size t► SQ i No. No. DIN , Stories Units New A-dd ❑ Alter ❑ Repair P Demolition ❑ Side Street Setback from Center Line tiELifVA IfoA,) A IWOU 3 3, 6 Y &4AlA/riV6 6Y2 4�L FINAL DATE IN�' -- ~UfDr�t (no,vc*cr ' A14Rk Nual' s (?o stimate a uatjon ►y PERMIT / AMOUNT Plan Chk. Dep. Plan Chk. Bal. u Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE IN�' -- ~UfDr�t Issued by: Date t pU p Re Validated by: A . ►,.�'f . Validation: f)J i♦ " _—'CIMANCE YELLOW=APPLICANT PINK = BUILDING DIVISION Notice: Document Cannot Be Duplicated Date 10/17/00 No. 21103 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE Owner NameCapital Pacific Homes, Inc. No. 78-930 Street Citrus City La Quinta Tract # 24890-4 Type of Development Comments Lot # 3 Single Family Residence APN # 772-101-003 Jurisdiction La Quinta Permit # 0008-178 Log # Zip 92253 Study Area Square Footage 1 Family Dwelling @ 4597 sq. ft. is in the Citrus - grandfathered. No. of Units 1 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: Under Mitigation Agreement EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 628.00 X 1 or $ 628.00 the property listed above and that building' permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By CC / Wells Fargo & Co. / Mark Mullin Telephone- _ _ Name on the check By Dr. Doris Wilson Superintendent Fee collected /exem ted by Annette Barlow Signature Payment Received Check No $628.00 0643003104 40TICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified rbove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to bllect them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting OCT 13 2000 14:54 FR FIRST AMERICAN TITLE TO 2798617 P.20/25 FIRST AMERICAN TITLE October 13, 2000 0214:40 pm PST RIVERSIDE COUNTY 2000.01 TAX ROLL APN 772.101-003-7 TRA 020051 - CITY OF LA QUINTA Legal LOT 3 MB 218/001 TR 248MA Mail 4100 MACARTHUR BLV STE 200 NEWPORT BEACH CA 92660 Acq. Date: Doe No. 10/1997 : 0357620 Assessed Owner CAPITAL PACIFIC HOLDINGS Assessed Values Taxes Land 97,403 Status • CUSTOMER SERVICE REQUEST ONLY • BILL: 000048047 file:HCAProgram Files\BackWeb\NewSTS\htn l\report4000.html Report Origination ID: 03-RO3-=0 PAYMENTS AS OF 09!09!2000 1st Half 2nd Half Payment Date OPEN Total Tax 595.82 595.82 Tax Install 69.58 595.82 Penalty 1,181.64 Balance Due Net 97,403 Total Taxes Due 11.74 Special Assessments Included In Tax Amounts Fund Type Description 685859 MISC ASSMT CVWD AVLBLTY CHG IMP SS 6&2373 LNOSCP/LTG LA QUINTA LDSCP 8 LTG 58-0882 MISC ASSMT CVWD STANDBY CHARGES Total Of Special Assessments Additional Property Information TAX CODE USE CODE VESTING 000 YR NO Reference Notices • CUSTOMER SERVICE REQUEST ONLY • BILL: 000048047 file:HCAProgram Files\BackWeb\NewSTS\htn l\report4000.html Report Origination ID: 03-RO3-=0 PAYMENTS AS OF 09!09!2000 1st Half 2nd Half OPEN OPEN 1,191.64 595.82 595.82 59.58 69.58 595.82 595.82 1,181.64 Amount 30.00 11.74 10.00 51.74 PUI CODE R07 10/13/2000 CITY OF LA QUINTA ' PLAN CHECK CORRECTION LIST Gouvis Engineering 4400 Campus Dr Suite A Newport Beach, CA 92660 PLAN CHECK NO.: 0008-178 JOB ADDRESS: 78-930 Citrus AREA-S.F.- . 5345 , October 5, 2000 FINAL CHECK OCCUPANCY: R3/U1 TYPE -OF -CONST.: V -N The submitted plans and specifications have been reviewed by VANDORPE CHou ASSOCIATES. It is our professional opinion that the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTAand the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS, AND THE FOLLOWING CONDITIONS: 1. The soils engineer shall certify in writing that foundation plans and calculations satisfy requirements/ recommendations made in the soils report. (As requested in soils report page 5) City to verify prior to issuance of building permit. Plans checked by: Dorothy Gordon, P.E. VANDORPE CHOu ASSOCIATES. 295 N Rampart Street, Suite A Orange CA 92868 (714) 978-9780 ' VCA File No. LQ712371 1 i Earth Systems '�� Southwest October 12, 2000 Capital Pacific Homes, Inc. 1101 California Avenue, Suite 101 Corona, California 92660 Attention: Mr. Mark Mullin Project: Tract 24890-4 The Citrus Course La Quinta, California Subject: Plan Review References: 79-811B Country Club Drive Bermuda Dunes, CA 92201 (760)345-1588 (800)924-7015 FAX (760) 345-7315 File No.: 07687-03 00-10-754 1. Soil Engineering Report for La Quinta Lodge, prepared by Buena Engineers, Inc., File No.: B -16006-P1, Report No.: 86-2-271. 2. Project Plans for "The Premier Collection", Unit Plans IA, 1B, 1C, 2A, 2B, 2E, 3A, 3B, and 3D, prepared by Pekarek-Crandell, Inc., dated September 18, 2000. As required by the City of La Quinta, we have reviewed the geotechnical engineering report prepared by Buena Engineers, Inc. in conjunction with the project plans. Based on our review of these documents, it is our opinion that the referenced plans are in substantial compliance with the referenced soil engineering report. We make no representation as to the accuracy of the dimensions, measurements, calculations, or any portion of the design. If you have any questions or require additional information, please contact this office at your convenience. Respectf EARTH CE 38234 EXP. 3/31/01 Craig S. r clvn CE 38234 q�oFCq��FD Distribution: _ 2/Capital Pacific Homes, Inc. INTA File IBD File -S ' STS ro-% •Earth Systems Consultants Southwest September 28, 1999' Capitol Pacific Holdings P.O. Box 7150 Newport Beach, California Attention: Mr. Manuel De La Torre 79-811 B Country Club Drive Bermuda Dunes, CA 92201 (760) 345-1 SS8 (800)924-7015 FAX (760) 345-7315 File No. 07367-01 99-09-789 Subject: Soil Engineering Report Update with Supplemental Recommendations Project: Tract 24890-1 Lots 1-20 The Citrus, La Quinta, California References: 1. Soil Engineering Report' La Quinta Lodge, La Quinta, California, prepared by Buena Engineers, Inc., File No. B -16006-P1, Document No. 86-02-271, dated February 25, 1986. 2. Rough Grading Report prepared by Buena Engineers, Inc. dated July 17, 1986; Job No. B -16006-P1, Report No. 86-7-223. 3. Rough Grading Report prepared by Soil and Testing Engineers, Inc. dated May 21, 1990; STE 8931087, Report No. 8. As requested, we have reviewed referenced documents for purposes of updating the soils report and providing supplemental recommendations. This review included a reconnaissance of the site, and sampling of upper soils to test for pH, resistivity, soluble chloride, and soluble sulfate. The subject lot was originally mass -graded as part of the development. Site Grading Based upon our review of the soil testing at the subject tract, performed through 1990, it is our opinion that the grading has been performed in general accordance with the project plans and above referenced geotechnical engineering report. The subject tract area was prepared and compacted as part of the overall mass grading that included the removal and recompaction of the upper 2 feet of soil below original grade or 3 feet below finish grade. It is our opinion that the subject pad was graded adequately for the proposed use. Since over one year has passed since the finish grading, we recommend some remedial effort prior to precise grading and building construction. y. Septcmber.29, 1999 2 File No. 07367-01 99-09-789 The building pad area should be initially prepared by removing any organic growth from the pad surface. The pad should then be moisture conditioned by the use of sprinklers or rain birds to a depth of 2 feet below the current pad grade. If the current pad elevation is to be altered from its current elevation, fills should be compacted to at least 90% relative compaction (ASTM D1557) near its optimum moisture. If the pad is to be lowered in elevation, the depth of moisture conditioning may need to be increased. Additionally, depending upon the depth of cut (if any), additional over -excavation and compaction may be required. Site Drainage Control of surface drainage is important to the successful development of the property. Surface drainage control should be provided throughout the completed project to protect the future stability of foundations and other site improvements. A positive gradient should be provided away from structures and should be directed towards an approved drainage discharge area in a non-erosive manner. Down spouts from the roof of the houses should discharge collected rainwater onto splash blocks, adjacent paved areas, or be tied into awater-tight drainage pipe, which would carry the collected water away from the houses to approved point(s) of discharge. Rear and side yard surface drainage should not be allowed to be blocked from flowing to approved points of discharge by future sidewalks, patios, or landscaping. Landscaping should be such that excess irrigation water is not allowed to pond on or near the structure or areas to be paved. Additionally, care should be taken so as not to over water landscaped areas. Irrigation should be only sufficient to sustain plant life. Failure to control excess moisture may result in settlement and soil erosion that could compound the problem by rupturing water lines or other services or utilities, this introducing additional moisture into the underlying soil. Foundations The residential structures can be supported on shallow foundations bearing on a zone of properly prepared and compacted soils as referenced above under "Site Grading." The recommendations that follow are based on very low expansion category soils. Allowable soil bearing pressures are given below for foundations bearing on recompacted soils as described above. Allowable bearing pressures are net (weight of footing and soil surcharge may be neglected). The soil bearing pressures are based on the 1986 soils engineering report. • C.onti_nuous,wall-.foundations, 12 -inch minimum width and 12 inches below grade: — 1-100 psf for -dead -plus design live loads? • Isolated pad foundations, 2 x 2 foot minimum in plan and IS inches below grade: 1700 psf for dead plus design live loads. Allowable increases of 200 psf per each foot of additional footing width and 300 psf for each additional 0.5 foot of footing depth may be used. A one-third (1/3) increase in the bearing EARTH SYSTEMS CONSULTANTS SOUTHWEST r September.29, 1999 3 File No. 07367-01 99-09-789 pressure may be used when calculating resistance to wind or seismic loads. The maximum allowable bearing pressure should limited to 2500 psf. Foundation excavations should be observed by a representative of ESCSW during excavation and prior to placement of reinforcing steel or concrete. Local variations in conditions may require deepening of footings. Any loose soil or construction debris should be removed from footing excavations prior to placement of concrete. Lateral loads may be resisted by soil friction on the base of foundations and by passive resistance of the soils acting on foundation stem walls. Lateral capacity is based partially on the assumption that any required backfill adjacent to foundations and grade beams is properly compacted. An allowable coefficient of friction of 0.30 may be used for dead load forces. An allowable equivalent fluid pressure of 200 pcf may be included for resistance to lateral loading. These values include a factor of safety of 1.5. Passive resistance and frictional resistance may be combined in determining the total lateral resistance. However, the friction factor should be reduced to 0.20 of dead load forces. A one-third (1/3) increase in the passive pressure may be used when calculating resistance to wind or seismic loads. Concrete Slabs -on -Grade Subo_Tade: Concrete slabs -on -grade and flatwork should be supported by compacted soil as discussed above and in the referenced geotechnical engineering report. Vapor Barrier: In areas of moisture sensitive floor coverings, an appropriate vapor barrier should be installed in order to reduce the potential for moisture transmission from the subgrade soil to the slab. The effectiveness of the moisture barrier is dependent upon the quality of the product, methodology/quality of the overlaps, protection of the barrier during construction, and the successful sealing off the barrier around utility lines. We recommend that an impermeable membrane (6 -mil plastic) underlie the floor slabs. The membrane should be covered with 2 inches of sand to help protect it during construction and to aide in concrete curing. The sand should be lightly moistened just prior to placing the concrete. Low -slump concrete should be used to help minimize shrinkage. Slab thickness and reinforcement: Slab thickness and reinforcement of slab -on -grade are contingent upon the structural engineer's or architect's recommendations and the expansion index of the supporting soil. Based upon our findings, a :modulus of subgrade reaction of approximately 200 pounds per cubic inch can be , used in concrete slab design for every low expansion category soils as encountered at the site' Concrete slabs and flatwork should be a, minimum of 4 inches thick. Concrete floor slabs may either be monolithically placed with the foundations or doweled after footing placement. However, the design engineer/architect should consider the potential adverse effects of temperature changes when providing recommendations for concrete slabs as well as the effects of a free floating slab versus slabs tied to the adjacent footings. The project architect or geotechnical engineer should continually observe all reinforcing steel in slabs during placement of concrete to check for proper location within the slabs and/or footings. EARTH SYSTEMS CONSULTANTS SOUTHWEST September.29, 1999 4 File No. 07367-01 99-09-759 Control Joints: Control joints should be provided in all concrete slabs -on -grade at a maximum spacing of 36-x slab thickness (12 feet maximum on -center, each way) as recommended by American Concrete Institute (ACI) guidelines. All joints should form approximately square patterns to reduce randomly oriented contraction cracks. Contraction joints in the slabs should be tooled at the time of the pour or saw cut (1/4 of slab depth) within 8 hours of concrete placement. Construction (cold) joints should either be thickened butt joints with one-half inch dowels at 24 -inches on center or a thickened keyed joint to resist vertical deflection at the joint. All construction joints in exterior flatwork should be sealed to reduce the potential of moisture or foreign .material intrusion. Precautions should be taken to prevent curling of slabs in this and desert region during the curing process. The contractor should take precautionary measures to ensure proper batching of the concrete, proper placement (without effecting the maximum water/cement ratio), proper finishing, and proper curing. These procedures will reduce the potential for randomly oriented cracks, however, may not eliminate them from occurring. Mitigation of Soil Corrosivity on Concrete Two samples of the upper 12 inches of native soil were obtained and tested for pH, resistivity, soluble chloride, and soluble sulfate (results are pending and will be submitted in a separate letter). This type of testing serves as an indicator as to the potential adverse effects of reinforcing steel, concrete, and buried pipes. Based on other testing on the site we anticipate the soils to have low sulfate ion concentration and low chloride ion concentrations. Sulfate ions can attack the cementitious material in concrete, causing weakening of the cement matrix and eventual deterioration by raveling. Chloride ions can cause corrosion of reinforcing steel. The Uniform Building Code does not require any special provisions if low sulfate conditions exist, but requires a low water/cement ratio and extra strength concrete if higher sulfate conditions exist. ' Nonetheless, a minimum concrete cover of 3 inches should be provided around steel reinforcing or embedded components exposed to native soil or landscape water (to 18 inches above grade). Additionally, the concrete should be thoroughly vibrated during placement. Corrosion protection of steel pipes can be achieved by using epoxy corrosion inhibitors; asphalt coatings, cathodic protection, or encapsulating with densely consolidated concrete. Aqualified corrosion engineer should be consulted regarding mitigation of the corrosive effects of site soils on metals. Seismic Design At a minimum, design of structures should conform to the 1997 edition of the Uniform Building Code (UBC). It should be noted that the UBC is generally intended to protect human safety and prevent structural collapse. They are not necessarily intended to prevent structural damage or preserve functionality after a large earthquake. Therefore, more stringent seismic designs should be considered if a particular level of structural performance is desirable after a large earthquake. That design should be based on a site and project specific seismicity analysis. ARTFI S�'STE,�IS COiNSULT.ANTS SOUTH�VGS'F - September.29, 1999 5 File No. 07367-01 99-09-789 The following are updated 1997 UBC seismic design values. Reference Seismic Zone: 4 Figure 16-2 Seismic Zone Factor, Z: 0.4 Table 16-I Soil Profile Type: Sp Table 16-S Seismic Source Type: A Table 16-U Closest Distance Known to Seismic Source: 10 km =6.3miles (San Andreas Fault) Near Source Factor Na: 1.00 Table 16-S Near Source Factor, Nv: 1.20 Table 16-T Seismic Coefficient, Ca: 0.44 =0.44Na Table 16-Q Seismic Coefficient, Cv: 0.77 =0.64Nv Table 16-R Summary Except as modified, it is our opinion that the referenced documents are applicable to the proposed development. We' make no representation as to the accuracy of the dimensions, measurements, calculations, or any portion of the design. As the Geotechnical Engineer of Record for this project, Earth Systems Consultants Southwest (ESCSW) has striven to provide our services in accordance with generally accepted geotechnical engineering practices in this locality at this time. No warranty or guarantee is express or implied. This report was prepared for the exclusive use of the Client and their authorized agents. cES_CSW=should`6e -provided the opportunity -for a general review of final design and, specifications --in order. that earthwork and foundation recommendations may be properly. -interpreted-and implemented in the design and specifications. If ESCSW is not accorded the privilege of making this recommended review, we can assume no responsibility for misinterpretation of our recommendations. EARTH SYSTEMS CONSULTANTS SOUTHWEST September.29, 1999 Cel File No. 07367-01 99-09-789 This update report is based on the assumption that an adequate program of client consultation, construction monitoring, and testing will be performed during the final design and construction phases to check compliance with these recommendations. Maintaining ESCSW as the geotechnical consultant from beginning to end of the project will provide continuity of services. The geotechnical engineering firm providing tests and observations shall assume the responsibility of Geotechnical Engineer of Record. Should'you have any questions concerning our report please give us a call and we will be pleased to assist you. Sincerely, EARTH SYSTEMS CONSULTANTS Southwest Shelton L. Stringer GE 2266 SER/tg Distribution: 4/Capitol Pacific Holdings 1/ESI 1/VTA File 1/BD File Q�or-ESS/o^I <� co y � m No. 2266 \�J'TgjF0 CHN �OF CA EARTH SYSTEMS CONSULTANTS SOUTHWEST ) Aug 07 00 02:26p Earth S3stems Consultants 760.345-7315 Earth Systems Consultants Southwest . - 79-811 B Country Club Drive Bermuda Dunes, CA 92201 (760) 345-1588 (800) 924-7015 FAX (760) 345-7315 FACSIMILE MEMORANDUM Page: 1 of 1 To: Mike Company: Gouvis Engineering Fax #: (949) 762-6321 From: Shelton L. Stringer, GE Date: 06/21/99 Project: Tract 24890, The Citrus Course, La 4uinta, CA ESCSW Project No: 04442-10 Document No: 98-00.791 Message: 1997 UNIFORM BUILDING CODE (UBC) SEISMIC PARAMETERS, Chapter 16 1997 UBC Reference Seismic Zone: 4 Figure 16-2 Seismic Zone Factor, Z: 0.4 Table 16-1 Soil Profile Type, S D Table 16-S Seismic Source Type: A Table 16-U Closest Dlstance to Known Seismic Source: •10 km = 6-1/4 miles (San Andreas Fault) . Near Source Factor, Na: 1.00 Table 16-S Near Source Factor, Nv: 1.20 Table 16-T Seismic Coefficient, Ca: 0.44 = 0.44Na Table 16-Q Seismic Coefficient, Cv: 0.77 = 0.64Nv Table 16-R FOUNDATION RECOMMENDATIONS (Cited from original 1986 Buena soils report) Based on footings and slabs bearing on non -expansive, compacted subgrade, previously mass graded Allowable Bearing Capacities: Wall Footings, 12 -inch minimum width: 1100 psf Column Footings, 24 -inch minimum width: 1700 psf Above values based on minimum embedment of 12 and 18 inches for wall & column footings, respectively Allowable Increases: 300 psf for each additional 0.5 foot of depth X00 psf for each additional foot of width Maximum not to exceed: 1/3 increase permitted for seismic and wind forces Allowable Passive Resistance (FS=1.5): Allowable Coefficient of Base Friction (FS=1.5): Estimated Settlements, Total: Lateral Earth Pressures, Level ground, Active: p.2 I THE PREMIER COLLECTION PLAN 2 EQUIPMENT SCHEDULE - ZONE 1 Gti/C� EQUIPMENT SCHEDULE - ZONE 2 BRAND R VALUE BTU/H TONS AFUE SEER MANUFACTURER DUCT(R-VALUE) 4.2 T -STAT HONEYWELL FURNACE YORK 64,000 80% COIL YORK 64,000 3.5 12.0 CONDENSER YORK 42,000 3.5 EVAPORATOR PLENUM SIZE HEATING COOLING EQUIPMENT SCHEDULE - ZONE 2 EQUIPMENT SCHEDULE - ZONE 3 BRAND R VALUE BTU/H TONS AFUE SEER MANUFACTURER DUCT(R-VALUE) 4.2 T -STAT HONEYWELL FURNACE YORK 64,000 80% COIL YORK 64,000 3.5 12.0 CONDENSER YORK 42,000 3.5 EVAPORATOR PLENUM SIZE HEATING COOLING EQUIPMENT SCHEDULE - ZONE 3 BRAND R VALUE BTU/H TONS AFUE SEER MANUFACTURER DUCT(R-VALUE) 4.2 T -STAT HONEYWELL FURNACE YORK 64,000 80% COIL YORK 64,000 4.0 12.0 CONDENSER YORK 48,000 4.0 EVAPORATOR PLENUM SIZE HEATING COOLING THE PREMIER COLLECTION La Qunita Climate Zone # 15 Plan 2 -Lot 3: Revised: Capital Pacific Holdings Pekarek-Crandell Inc. -130 CtiTRJs CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION SAT E o 00 BY HERITAGE ENERGY GROUP September 8, 2000 Title 24 Energy Calculations (949) 789-7221 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to -implement them. This certificate has been signed by the individual with overall design responsibility.. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name .... . MA Y, (0 . ��,.� Company. Capital Pacific Holdings Address. 1101 California St # 100 Corona CA 92881 Phone... lior, - P 79 - of 4147 License.-74p'lyS. _ - . 111./,1/l_'/Af./,A zMz1M (date) ENFORCEMENT AGENCY Name.-. . . Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Sam Maimone .Company. Heritage Energy Group Address. 15375 Barranca Pkwy, Suite F-101 Irvine, CA 92618 Phone... 94R-789-7221 Signed.. [ L(date) CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R ------------------------------------ -- Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 Project Address........ The Premier Collection ******* --------------------- La Quinta *v5.10* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. .. 15 --------------------- Compliance Method...... MICROPAS-5 v5.10 for 1998 Standards by Enercomp, Inc. ------------- ------------------- MICROPAS5 v5.10 File-99299M2B Wth-CTZ15S92 Program -FORM CF -1R User#-MP0940 User -Heritage Energy Group Run- ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 4597 sf Building Type .............. Single Family Detached Construction Type ......... New: Building Front Orientation. Front Facing 135 deg (SE) Number of Dwelling Units... 1 Number of Stories... ...... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 18.2 % of floor area Average Glazing U -value.... 0.52 Btu/hr-sf-F. Average Glazing SHGC....... 0.6 Average Ceiling Height..... 10.7 ft BUILDING SHELL INSULATION Component ------------------------- Frame Cavity Sheathing Total Assembly Type ------------- Type R -value R -value R -value U -value Location/Comments ------------------------------ ------------------------ ------ Wall Wood R-13 R-n/a R-13 0.088 Roof Wood R-30. R-n/a R-30 0.036 Door Metal R-0 R-n/a R-0 0.330 S1abEdge None R-0 R-n/a F2=0.760 S1abEdge None R-0 R-n/a F2=0.510 FENESTRATION ------------ Over- Area U- Interior Exterior hang/ Orientation (sf) Value SHGC Shading Shading Fins - ------------------- Window ----- ------ --------------------- Back (NW) 338.0 0.510 0.600 Standard -------------- Standard ----- Yes Window Back (NW) 56.0 0.510 0.600 Standard Standard None Door Right (NE) 48.0 0.550 0.600 Standard Standard Yes Window Right (NE) 85.0 0.510 0.600 Standard Standard Yes Window Left (SW) 96.5 0.510 0.600 Standard Standard Yes Window Front (S) 56.0 0.510 0.600 Standard Standard Yes Door Back (NW) 120.0 0.550 0.600 Standard Standard Yes Window Front (SE) 6.0 0.510 0.600 Standard Standard Yes Door Left (SW) 24.0 0.550 0.600 Standard Standard Yes Window Right (E) 6.0 0.510 0.600 Standard Standard Yes The following U -Values are for dual pane vinyl framed Fenestration:Operable: 0.51,; Fixed:0.51,Patio doors 0.55 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Plan 2 Lot 3 ------------------------------------------------------------------------------- Number Tank Page 2 CF -1R Date..09/08/00 11:51:32 ------------------------------------------------------------------------------- in SLAB SURFACES Insulation Tank Type Heater Type Distribution Type ---------------------------------------- ------ System -------- Factor (gal) ------ ---------- R -value -- ------------- Area 0.60 50 R- n/a American Water Heater G52 -50T38 -3N (or equal) - Slab Type ---------------- (sf) ------ Standard Slab 1956 Standard Slab 2641 HVAC SYSTEMS Minimum ------------ Duct Duct Tested Duct ACCA Thermostat Equipment Type Efficiency ------------ Location ------------ R -value ------- Leakage --------- Manual --------- D Type ------- ---------------- Furnace 0.800 AFUE Attic R-4.2 No No Setback ACSplit 12.00 SEER Attic R-4.2 No No Setback Furnace 0.800 AFUE Attic R-4.2 No No Setback. ACSplit 12.00 SEER Attic R-4.2 No No Setback Bedrooms: Minimum Heating Load: 32,360 Btuh Cooling Load: 33,585(Sensible), 40,302(Total) Living Rooms: Minimum Heating Load: 45,142 Btuh Cooling Load: 54,642(Sensible),65,570(Total) Note: The loads shown are'only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF -6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF -6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. WATER HEATING SYSTEMS --------------------- *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. lieu of a timer and temperature control. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. REMARKS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type ---------------------------------------- ------ System -------- Factor (gal) ------ ---------- R -value -- Storage Gas Recirc/TimeTemp 2 0.60 50 R- n/a American Water Heater G52 -50T38 -3N (or equal) *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. lieu of a timer and temperature control. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. REMARKS 'CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R ---------- -- --- Proiect Title.......... Plan 2 w/office Lot 3 Date..07/18/00 14:37:34 Project Address........ The Premier Collection ******* --------------------- La Quinta *v5.10* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. ..... 15 --------------------- Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. ----------------------- - ---------------------------------------- MICROPAS5 v5.10 File-99299MB1 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0940 User -Heritage Energy Group Run- ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 4833 sf Building Type. * ype.............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... Glazing Percentage......... Average Glazing U -value.... Average Glazing SHGC....... Average Ceiling Height..... Single Family Detached New Front Facing 135 deg (SE) 1 1 Slab On Grade 18.1 % of floor area 0.52 Btu/hr-sf-F 0.6 10.7 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type ------------- Type -------- R -value -------- R -value R -value U -value -------------- Location/Comments ------ Wall Wood R-13 ------------------------ R-n/a R-13 0.088 Roof Wood R-30. R-n/a R-30 0.036 Door Metal R-0 R-n/a R-0 0.330 S1abEdge None R-0 R-n/a F2=0.760 SlabEdge None R-0 R-n/a F2=0.510 FENESTRATION ------------ Over- Area' U- Interior Exterior hang/ Orientation (sf) Value SHGC Shading Shading Fins -------------------- Window Back (NW) ----= 338.0 ------ ----=---------------- 0.510 0.600 Standard -------------- Standard ----- Yes Window Back (NW) 56.0 0.510 0.600 Standard Standard None Door Right (NE) 48.0 0.550 0.600 Standard Standard Yes Window Right (NE) 85.0 0.510 0.600 Standard Standard Yes Window Left (SW) 96.5 0.510 0.600 Standard Standard Yes Window Front (S) 56.0 0.510 0.600 Standard Standard Yes Door Back (NW) 120.0 0.550 0.600 Standard Standard Yes Window Front (SE) 6.0 0.510 0.'600 Standard Standard Yes Door Left (SW) 24.0 0.550 0.600 Standard Standard Yes Window Right (E) 6.0 0.510 0.600 Standard Standard Yes Door Right (E) 40.0 0.550 0.600 Standard Standard Yes The following U -Values are for dual pane vinyl framed Fenestration:Operable: 0.51; Fixed:0.51,Doors 0.55 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Plan 2 w/office Lot ------------------------------------------------------------------------------- 3 Page 2 CF -1R Date..07/18/00 14:37:34 ------------------------------------------------------------------------------- Area Slab Type ---------------- (sf) ------ Standard Slab 2192 Standard Slab 2641 HVAC SYSTEMS Minimum ------------ Duct Duct Tested Duct ACCA Thermostat Equipment Type Efficiency Location R -value ------------------- Leakage --------- Manual --------= D: Type ------- ------------=--- Furnace ------------ 0.800 AFUE Attic R-4.2 No No Setback ACSplit 12.00 SEER Attic R-4.2 No No Setback Furnace 0.800 AFUE Attic R-4.2 No No Setback ACSplit 12.00 SEER Attic R-4.2 No No Setback Bedrooms: Minimum Heating Load: 32,360 Btuh Cooling Load: 33,585(Sensible),40,302(Total) Living Rooms: Minimum Heating Load: 45,142 Btuh Cooling Load: 54,642(Sensible),65,570(Total) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors.when selecting the HVAC equipment. That individual is required to provide Form CF -6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF -6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. WATER HEATING SYSTEMS Number Tank External in Energy. Size Insulation Tank Type Heater Type Distribution Type System Factor: (gal) R -value -- ---------------------------------------- -------------- ------ ---------- Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 American Water Heater G52-75T75-4NV (or equal) *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. lieu of a timer and temperature control. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. SPECIAL FEATURES AND MODELING ASSUMPTIONS ---------- 7 ------- ----------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and. field inspection. *** Mandatory Measures require a R-12 or greater external blanket.on Gas Storage Water Heaters with Energy Factors less than 0.58. REMARKS COMPUTER METHOD SUMMARY Page 1 C -2R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 Project Address........ The Premier Collection ******* --------------------- La Quinta *v5.10* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. ..... 15 --------------------- Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. MICROPAS5 v5.10 File-99299M2B Wth-CTZ15S92 Program -FORM C -2R User#-MP0940 User -Heritage Energy Group Run- ------------------------------------------------------------------------------- ----------------------------------------------------------------- ----------------------------------------------------------------- = MICROPAS5 ENERGY USE SUMMARY = ---------------------------- _ Energy Use Standard Proposed Compliance = _. (kBtu/sf-yr) _--------------------------------- Design Design ---------- Margin = ---------- _ = Space Heating.......... 3.67 4.27 -0.60 = = Space Cooling.....:.... 38.35 36.03 2.32 = = Water Heating.......... 6.20 6.66 -0.46 = = Total 48.22 46.96 1.26 = Zone Type SLEEPING Residence. LIVING Residence *** Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 4597 sf Building Type .............. Single Family Detached. Construction Type ......... New Building Front Orientation. Front Facing 135 deg (SE) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 2 49144 cf 4597 sf 18.2.% of floor area 0.52 Btu/hr-sf-F 0.6 10.7 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage (sf) (cf) Units itioned Type (ft) (sf) Credit 1956 19560 0.43 Yes Setback 2.0 Standard No 2641 29584 0:57 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Surface SLEEPING 23 S1abEdge 25 S1abEdge LIVING 24 S1abEdge 26 S1abEdge Form 3 Location/ Reference Comments ------------ ---------------- PERIMETER LOSSES ---------------- Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments --------------------- ----- ---------------------- 122 0.760 R-0 No 60 0.510 R-0 No 151 0.760 R-0 No 29 0.510 R-0 No Orientation ---------------------- SLEEPING 1 Window Back (NW) 2 Window Back (NW) 3 Window Back (NW) 4 Door. Right (NE) :5 Window Right (NE) 6 Window Left (SW) 7 Window Left (SW) .8 Window Left _(SW) �9 Window Left (SW) 1'0 Window Left (SW) 11 Window Left ($W) 12 Window Front (S) 13 Window Front (S) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ---- -------------- -------------- 40.0 0.510 0.600-315 90 Standard/0.76 Standard/0.68 20.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 56.0 0.510 0.600 3i5 90 Standard/0.76 Standard/0.68 24.0 0.550 0.600 45 90 Standard/0.76 Standard/0.68 8.0 0.510 0.600 45 90 Standard/0.76 Standard/0.68 8.0 0.510 0.600 225 90 Standard/0.76 Standard/0:68 6.0 0;.510'0.600-225 90 Standard/0.76 Standard/0.68 30.0 0.510 0.600225. 90 Standard/0.76 Standard/0.68 14.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 20.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 12.5 0.510 0.600. 225 90 Standard/0.76 Standard/0.68 25.0 0.510 0.600 180 90 Standard/0.76 Standard/0.68 25.0 0.510 0.600 180 90 Standard/0.76Standard/0:68 OPAQUE SURFACES Area U- --------------- Insul Act Solar Surface (sf) value R-val ----- Azm Tilt ---- Gains -------------- SLEEPING ------ ----- --- ----- 1 Wail 154 0.088 13 315 90 Yes 3 Wall 103 0.088 13 45 90 Yes 5 Wall 200 0.088 13 135 90 Yes 7 Wall 620 0.088 13 225 90 Yes 9 Wall 64 0.088 13 90 90 Yes 11 Wall 14 0.088 13 180 90 Yes 13 Wall .110 0.088 13 135 90 No 14 Wall 40 0.088 13 225 90 No 15 Wall :360 0.088 13 180 90 No 16 Wall 90 0.088 13 90 90 No 19 Roof 1956 0.036 30 n/a 0 Yes LIVING 2 Wall 282 0.088 13 315 90 Yes 4 Wall 622 0.088 13 45 90 Yes 6 Wall 214 0.088 13 135 90 Yes 8 Wall 163 0.088 13 225 90 Yes 10 Wall 60 0.088 13 90 90 Yes 12 Wall 60 0.088 13 180 90 Yes 17 Wall 90 0.088 13 135 90 No 18 Wall 95 0.088 13 90 90 No 20 Roof 2641 0.036 30 n/a 0 Yes 21 Door 48 0.330 0 135 90 Yes 22 Door 28 0.330 0 135 90 No Surface SLEEPING 23 S1abEdge 25 S1abEdge LIVING 24 S1abEdge 26 S1abEdge Form 3 Location/ Reference Comments ------------ ---------------- PERIMETER LOSSES ---------------- Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments --------------------- ----- ---------------------- 122 0.760 R-0 No 60 0.510 R-0 No 151 0.760 R-0 No 29 0.510 R-0 No Orientation ---------------------- SLEEPING 1 Window Back (NW) 2 Window Back (NW) 3 Window Back (NW) 4 Door. Right (NE) :5 Window Right (NE) 6 Window Left (SW) 7 Window Left (SW) .8 Window Left _(SW) �9 Window Left (SW) 1'0 Window Left (SW) 11 Window Left ($W) 12 Window Front (S) 13 Window Front (S) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ---- -------------- -------------- 40.0 0.510 0.600-315 90 Standard/0.76 Standard/0.68 20.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 56.0 0.510 0.600 3i5 90 Standard/0.76 Standard/0.68 24.0 0.550 0.600 45 90 Standard/0.76 Standard/0.68 8.0 0.510 0.600 45 90 Standard/0.76 Standard/0.68 8.0 0.510 0.600 225 90 Standard/0.76 Standard/0:68 6.0 0;.510'0.600-225 90 Standard/0.76 Standard/0.68 30.0 0.510 0.600225. 90 Standard/0.76 Standard/0.68 14.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 20.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 12.5 0.510 0.600. 225 90 Standard/0.76 Standard/0.68 25.0 0.510 0.600 180 90 Standard/0.76 Standard/0.68 25.0 0.510 0.600 180 90 Standard/0.76Standard/0:68 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- 28 Window Front (S) ----- 6.0 ----- 0.510 ----- --- 0.600 180 ---- 90 -------------- Standard/0.76 -------------- Standard/0.68 29 Window Right (E) 6.0 0.510 0.600 90 90 Standard/0.76 Standard/0.68 LIVING 14 Window Back (NW) 108.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 15 Window Back (NW) 48.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 16 Door , Back (NW) 120.0 0.550 0.600 315 90 Standard/0.76 Standard/0.68 17 Window Back (NW) 32.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 18 Window Back (NW) 20.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 19 Window Back .(NW) 43.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 20 Window Back -(NW) 16.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 21 Window Back (NW) 11.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 22 Window Right (NE) 47.0 0.510 0.600 45 90 Standard/0.76 Standard/0.68 23 Door Right (NE) 24.0 0.550 0.600 45 90 Standard/0.76 Standard/0.68 24 Window Right (NE) 30.0 0.510 0.600 45 90 Standard/0.76 Standard/0.68 25 Window Front (SE) 6.0 0.510 0.600 135 90 Standard/0.76 Standard/0.68 26 Door Left (SW) 24.0 0.550 0.600 225 90 Standard/0.76 Standard/0.68 27 Window Left (SW) 6.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface ----------- (sf) ----- Wdth ----- Hgth ----- Dpth ---- Hght Ext ---- ---- Ext ---- Ext Dpth Hght ---- ---- ---- Ext Dpth Hght ---- ---- ---- SLEEPING 1 Window 40.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 56.0 n/a 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 24.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 8.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 8.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 30.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 14.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 20.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 12.5 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 25.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 25.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a LIVING 14 Window 108.0 n/a 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 48.0 n/a 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 16 Door 120.0 n/a 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 32.0 n/a 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 43.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 11.0 n/a 8 2 2 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 47.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 23 Door 24.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 30.0 '6.0 n/a 8 2 1 n/a: n/a n/a n/a n/a n/a n/a n/a 25 Window- n/a 8 2 1 n/a n/a n/a h/a n/a n/a n/a n/a 26 Door 24.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 6.0 n/a 8 2 1 n/a:•n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Plan 2 Lot 3 Date..09/08/00 11:51:32 SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ SLEEPING Standard Slab 1956 LIVING Standard Slab 2641 HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ----------- -------- -------------- ------ ---------- 1 Storage Gas Recirc/TimeTemp 2 0.60 50 R- n/a REMARKS .Minimum Duct Duct Tested Duct ACOA Duct System Type ---------------- Efficiency ------------ Location ------------- R -value ------- Leakage --------- Manual D --------- Eff ------- SLEEPING Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 LIVING Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ----------- -------- -------------- ------ ---------- 1 Storage Gas Recirc/TimeTemp 2 0.60 50 R- n/a REMARKS COMPUTER METHOD SUMMARY Page 1 C -2R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... Plan 2 w/office Lot 3 Date..07/18/00 14:37:34 Project Address........ The Premier Collection ******* --------------------- La Quinta *v5.10* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. ..... 15 1 --------------------- Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS5 v5.10 File-99299MB1 Wth-CTZ15S92 Program -FORM C -2R User#-MP0940 User -Heritage Energy Group Run- ----------------------------------------------------------------------------=-- ----------------------------------------------------------------- ----------------------------------------------------------------- = MICROPAS5 ENERGY USE SUMMARY = = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 3.66 4.16 -0.50 = = Space Cooling.......... 38.10 36.02 2.08 = = Water Heating.......... 5.90 5.90 0.00 = = Total 47.66 46.08 1:58 = *** Building complies with Computer Performance ----------------------------------------------------------------- ----------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 4833 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 135 deg (SE) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 51504 cf Slab -On -Grade Area......... 4833 sf Glazing Percentage......... 18.1 % of floor area Average Glazing U -value.... 0.52 Btu/hr-sf-F Average Glazing SHGC....... 0.6 Average Ceiling Height..... 10.7 ft BUILDING ZONE INFORMATION ------------------------- Floor # of :Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type -------------- (sf) (cf) Units itioned ------------ ------------ Type (ft) (sf) ----------- ----- -------- Credit --------- SLEEPING Residence 2192 21920 0.45 Yes Setback 2.0 Standard No LIVING Residence 2641 29584 0.55 Yes Setback 2.0 Standard * No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Plan 2 w/office Lot 3 Date..07/18/00 14:37:34 ---------------------------=--------------------------------------------------- ------------------------------------------------------------------------------- I OPAQUE SURFACES --------------- Area U- !Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----- ------------ ------- SLEEPING j 1 Wall 154 0.088 13 315 90 Yes 3 Wall 103 0.088 f13 45 90 Yes 5 Wall 200 0.088 13 135 90 Yes 7 Wall 620 0.088 13 225 90 Yes 9 Wall 124 0.088 13 90 90 Yes 11 Wall 14 0.088 13 180 90 Yes 13 Wall 110 0.088 13 135 90 No 14 Wall 40 0.088 13 225 90 No 15 Wall 360 0.088 13 180 90 No 16 Wall 90 0.088 13 90 90 No 19 Roof 2192 0.036 30 n/a 0 Yes LIVING 2 Wall 282 0.088 13 315 90 Yes 4 Wall 622 0.088 13 45 90 Yes 6 Wall 214 0.088 13 135 90 Yes 8 Wall 163 0.088 13 225 90 Yes '10 Wall 60 0.088 13 90 90 Yes .12 Wall 60 0.088 13 180 90 Yes :17 Wall 90 0.088 13 135 90 No 18 Wall 95 0.088 13 90 90 No 20 Roof 2641 0.036 30 n/a 0 Yes 21 Door 48 0.330 0 135 90 Yes 22 Door 28 0.330 0 135 90 No PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- SLEEPING 23 SlabEdge 142 0.760 R-0 No 25 SlabEdge 60 0.510 R-0 No LIVING 24 SlabEdge 151 0.760 R-0 No 26 SlabEdge 29 0.510 R-0 No FENESTRATION SURFACES ---------------------- Area U- Act Exterior Shade Interior Shade Orientation (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC ---------------------- ----- ----- ----- --- ---- -------------- -------------- SLEEPING 1 Window Back (NW) 40.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 2 Window Back (NW) 20.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 3 Window Back (NW) 56.0 0.510 0.600 315 90 Standard/0.76 Standard/0.68 4 Door Right (NE) 24.0 0.550 0.600 45 90 Standard/0.76 Standard/0.68 5 Window Right (NE) 8.0 0.510 0.600 45 90 Standard/0.76 Standard/0.68 6 Window Left (SW) 8.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 7.Window Left (SW) 6.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 8 Window Left (SW) 30.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 9 Window Left (SW) 14.0 0.510 0.600 225 90 Standard/0.76 Standard/0.68 10 Window Left (SW) 20.0 0.51.0 0.600 225 90 Standard/0.76 Standard/0.68 11 Window Left (SW) 12.5 0.510 0.600 225 ;90 Standard/0.76 Standard/0.68 12 Window Front (S) 25.0 0.510 0.600 180 '90 Standard/0.76 Standard/0.68 13 Window Front (S) 25.0 0.510 0.600 180 90 Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Plan 2 w/office Lot 3 Date..07/18/00 14:37:34 --------------- Orientation ---------------------- 28 Window Front (S) 29 Window- Right (E) 30 Door Right (E) LIVING 315 90 14 Window Back (NW) 15 Window Back (NW) 16 Door Back (NW) 17 Window Back (NW) 18 Window Back (NW) 19 Window Back (NW) 20 Window Back (NW) 21 Window Back (NW) 22 Window Right (NE) 23 Door Right (NE) 24 Window Right (NE) 25 Window Front (SE) 26 Door Left (SW) 27 Window Left (SW) Surface SLEEPING 1 Window 3 Window .4 Door 5 Window 6 Window 7 Window 8 Window 9 Window 10 Window 11 Window 12 Window 13 Window 28 Window 29 Window 30 Door LIVING 14 Window 15 Window 16 Door 17 Window 19 Window 21 Window 22 Window 23 Door 24 Window 25 Window 26 Door 27 Window FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ---- -------------- -------------- 6.0 0.510 0.600 180 90 Standard/0.76 Standard/0.68 6.0 0.510 0.600 90 90 Standard/0.76 Standard/0.68 40.0 0.550 0.600 90 90 Standard/0.76 Standard/0.68 108.0 0.510 0.600 315 90 48.0 0.510 0.600 315 90 120.0 0.550 0.600 315 90 32.0 0.510 0.600 315 90 20.0 0.510 0.600 315 90 43.0 0.510 0.600 315 90 16.0 0.510 0.600 315 90 11.0 0.510 0.600 315 90 47.0 0.510 0.600 45 90 24.0 0.550 0.600 45 90 30.0 0.510 0.600 45 .90 6.0 0.510 0.600 135 90 24.0 0.550 0.600 225 90 6.0 0.510 0.600 225 90 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.76 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 Standard/0.68 OVERHANGS AND SIDE FINS ----------------------- --- Window- ------Overhang ----- ---Left Fin--- ---Right Fin -- Area Left Rght (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 40.0 --- 40.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 56.0 n/a 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 24.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 8.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 8.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 30.0 n/ a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 14.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 20.0 n/ a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 12.5 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 25.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 25.0 n/a 8 2 0 n/a n/a n/a n/a n/a n/a n/a n/a 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 6.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 40.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 108.0 n/a 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 48.0 n/a 8 10 2 n/a :n/a n/a n/a n/a n/a n/a n/a 120.0 n/a 8 10 2 n/a n/a n/a n/a n/a n/a n/a n/a 32.0 n/a 6 1 0 n/a n/a n/a n/a n/a n/a n/a n/a 43.0 n/a 8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 11.0 n/a 8 2 2 n/a n/a n/a n/a n/a n/a n/a n/a 47.0 n/a 8 2 1 n/a n/a. n/a n/a n/a n/a n/a n/a 24.0 n/a 8 2 1 n/a -n/a n/a n/a n/a n/a n/a n/a 30.0 n/ a. 8 2 1 n/a n/ a n/a n/a n/a n/a n/a n/a 6.0 n/a .8 2 1 n/a n/a n/a n/a n/a n/a. n/a n/a 24.0 n/a '.8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a 6.0 n/a ;.8 2 1 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Project Title.......... Plan 2 w/office Lot 3 SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ SLEEPING Standard Slab 2192 LIVING Standard Slab 2641 HVAC SYSTEMS Page 4 C -2R Date..07/18/00 14:37:34 WATER HEATING SYSTEMS Number Tank : External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal)' R -value ------------ ----------- ------------------- -------------- ------ ---------- 1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans,-*** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. REMARKS Minimum Duct Duct Tested Duct ACCA Duct System Type ----------------------------- Efficiency Location ------------- R -value ------- Leakage --=------ Manual D --------- Eff ------- SLEEPING Furnace 0.800 AFUE Attic R-4.2 No No 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 LIVING Furnace 0.800 AFUE Attic R-4.2 No No' 0.743 ACSplit 12.00 SEER Attic R-4.2 No No 0.596 WATER HEATING SYSTEMS Number Tank : External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal)' R -value ------------ ----------- ------------------- -------------- ------ ---------- 1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans,-*** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. REMARKS