04-3386 (SFD)P
i
QIP P.O. Box 1504�//�i�!
�'�`"'78 495 CALLE TAMPICO
SLA-QUINTA�-C=kLIIFORNIA 92253
BUILDING PERMIT
BUILDING & SAFETY DEPARTMENT
(760).777-7012
FAX (760) 777-7011
INSPECTION REQUESTS (760) 777-7153.
Application Number .
. . . . 04-00003386 Date
8/16/04
Property Address . .
. . . . 52785 CLARET COVE
APN:
770-330-010- - -
Application description
. . . DWELLING - SINGLE FAMILY DETACHED
Property Zoning . . .
. . . tOW DENSITY RESIDENTIAL
Application valuation
. . 439815
Owner
Contractor
JOHN CHASE
SUN VISTA DEVELOPMENT
CORPORAT
PO BOX 8349
P.O. BOX 1144
STOCKTON
CA 95212 LA QUINTA
CA 92247
(760) 771-4722
WCC: STATE FUND
WC: 17054604
01/01/05
CSLB: 744091
12/31/05
CCC: B .
--------------------------
Structure Information --------------------------
Construction Type . .
. . . TYPE V. - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <.=10
Flood ZoneNON-AO
FLOOD ZONE
Other struct info . .
. . . CODE EDITION 2001
CBC
# BEDROOMS
4.00
FIRE SPRINKLERS NO
GARAGE SQ FTG
904.00
PATIO SQ FTG
413.00
NUMBER OF UNITS
1.00
FIRST FLOOR SQ FTG
5156.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
Permit Fee
1829.50 Plan Check Fee
1189.18
Issue Date . . . .
Valuation . . . .
439815
Qty Unit Charge
Per
Extension
BASE FEE
639.50
340.00 3.5000
THOU BLDG 100,001-500,000
1190.00
----------------------------------------------------------------------------
Permit . . . . . .
MECHANICAL
Additional desc
Permit Fee . . . .
152.00 Plan Check Fee
38.00
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge Per
Extension
P.O. Box 1504�� VOICE (760) 777-7012
TdY
78-495 CALLE TAMPICo FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: O !q s384
Applicant:
Applicant's Mailing Address:
Date:
Architect or Engineer:
Architect or Engineer's Address:
Lic. No.:
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my se is i full force an effect. ' /
License Class t�r� (AC_ License No. � ieb
Date Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale: If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
is ue M er ' om ensation insurance carrier an otic number e:
Carrier y Policy Number /�n C L,/�d�
Tcerti' y that, in the peff#€ormance of the work for which this is ued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
Date Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSAT N COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation. '
I certify that I have read this application and state that the above information is correct.. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this coun�enteth love -mentioned property for inspection purposes.
Date �� Signature (Applicant or Ag t):
Application Number . . . . . 04-00003386
Page 2
Date 8/16/04
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
4.00
9.0000
EA
MECH
FURNACE <=100K
36.00
4.00
9.0000
EA
MECH
B/C <=3HP/100K BTU
36.00
.9.00
6.5000
EA
MECH
VENT FAN
58.50
1.00
6.5000
EA
MECH
EXHAUST HOOD
6.50
----------------------------------------------------------------------------
Permit .
. . . . .
ELEC-NEW RESIDENTIAL
Additional
desc
Permit.Fee
. . . .
228.54
Plan Check Fee
57.14
Issue Date
-
Valuation
0
Qty
Unit Charge
Per
"Extension
BASE
FEE
15.00
5156.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
180.46
904.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
18.08
1.00
15.0000
EA
ELEC
TEMPORARY POWER POLE
15.00
----------------------------------------------------------------------------
Permit .
. . . . .
PLUMBING
Additional
desc
Permit Fee
.. . . .
226.50
Plan Check Fee
56.63
Issue Date
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
24.00
6.0000
EA
PLB
FIXTURE
144.00
1.00
15.0000
EA
PLB
BUILDING SEWER
15.00
2.00
7.5000
EA
PLB
WATER HEATER/VENT
15.00
1.00
3.0000
EA
PLB
WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB
LAWN SPRINKLER SYSTEM
9.00
14.00
.7500
EA
PLB
GAS PIPE >=5
10.50
1.00
15.0000
EA
PLB
GAS METER
15.00
----------------------------------------------------------------------------
Permit .
. . . . .
GRADING PERMIT
Additional
desc
Permit Fee
. . . .
15.00
Plan Check Fee
.00
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
--------------------7-------------------------------------------------------
Special Notes and Comments
5156 S.F.
SFD PERMIT
DOES
NOT
t ,,
Page 3
Application Number . . . . .
04-00003386 Date
8/16/04
----------------------------------------------------------------------------
Special Notes and Comments
INCLUDE BLOCK WALL,
POOL/SPA : COMPLIANCE WITH ALL
FEDERAL &
STATE LAWS, INCLUDING THE ENDANGERED
SPECIES ACT OF 1973 (16U.S.C.
1531, ET
SEQ.) IF APPLICABLE, IS REQUIRED
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
ART IN PUBLIC PLACES -RES
599.53
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
118.92
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
43.98
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged
----------------- ----------
Paid Credited
---------- ---------- -----
Due
- ----
Permit Fee Total 2451.54
.00 .00
2451.54
Plan Check Total 1340.95
1000.00 .00
340.95-
40.95Other
OtherFee Total 3167.43
.00 .00
3167.43
Grand Total 6959.92
1000.00 .00
5959.92
City La Quinta Zip 92253 Permit #
Tract # Study Area
Type Single Family Residence No. of Units 1
Lot # No. Street
Unit 1 52785 Claret Cove
Unit 2
Unit 3
Unit 4
Unit 5
Comments
S.F.
5156 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Lot # No. Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24X 5,156 S.F. or $11,549.44 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/1 st Bank -Rob Capetz Check No. 74172
Name on the check Telephone
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Vanessa Robles
SignatureF In
,
:moi' i%. _ s
Funding Residential
Payment Recd 1$0.00
$11,549.44 Over/Under
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original- Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
Certificate-ofncOccupaY
OF I9wBuilding & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 52-785 CLARET COVE
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-3386
Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL
Owner of Building: JOHN CHASE Address: P.O. BOX 8349
City, ST, ZIP- STOCKTON, CA 95212
By: DANNY CRAWFORD
Date- AUGUST 25, 2005
Building Official
POST IN A CONSPICUOUS PLACE
CITY OF LA QUINTA
BUILDING & SAFETY DEPARTMENT
OF 777-7012
INSPECTION REQUEST LINE
777-7153
Owner JOHN CHASE
Contractor SUN VISTA DEV.
Permit Number 04-3386
POST ON JOB IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS 52-785 CLARETCOVE
5156 S.F. SFD PERMIT DOES NOT INCLUDE
BLOCK WALL, POOL/SPA `
TYPE OF INSPECTION DATE INSP.
TEMPORARY POWER
SETBACKS
U/G PLUMBING / WASTE t;v
U/G ELECTRICAL / GROUNDING
FOOTINGS / STEEL
CONCRETE SLAB
i 2✓� � G
DO NOT POUR CONCRETE UNTIL ABOVE 9IGNO
ROOF NAIL / PRE -ROOF
OKAY TO WRAP
FRAMING COMBINATION /
ROUGH ELECTRIC
ROUGH PLUMBING
ROUGH MECHANICAL
INSULATION
i COVERNO WORK UNTIL ABOVE SIGNED
INTERI BD. "(DRYWALL)
DS—
RIO R TH ,
AS TEST p
S BANDONMENT
SEWER CONNECTION / jS—
S SEPTIC / GREASE INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS /'STEEL
BOND BEAM 1
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL
PRE -PLASTER ALARMS/ BARRIERS
FINAL INSPECTIONS
TEMP. USE OF PERMANENT POWER
ELECTRICAL
PLUMBING
MECHANICAL
PUBLIC WORKS DEPARTMENT
' COMMUNITY DEVELOPMENT DEPT.
FINAL / JOB COMPLETED
>l?4r4S37 .
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING
Ma.r-' O1 05 11:01a Benjamin Herbst
(208) 325-8149 P.1
V/m" 5 - e0
Summit Structural Engineering
106 E. Park Street, Ste. 2C6
McCall, ID 83638
_- r (866) 862-8148
1 �
(208) 634-8148
Fax (208) 634-4157
March 1, 2005
Sun Vista Development, Inc. _
P.O. BOX 1144
La Quinta, CA 92253
Attn: Rob Capetz
Subject: Gas line notches at mechanical room studs — Chase Residence
Lot 46 @ The Tradition
La Quinta, CA
Dear Rob,
Per your request, we are providing additional engineering for the notching of the 2x6
studs at mechanical room 4 adjacent to the north side office bath. We understand that
the mechanical trades over notched the studs during the installation of the gas line.
Please install Simpson stud shoes (SS1.5) at the. notched studs.
If you have any questions, please give me a call.
Yours truly,
SUMMIT STRUCTURAL ENGINEERING a,
A. 0 --
No.
No. 0054193 m
Benjamin Herbst, P.E.
BH
gAMy Documents\2004\jobfiles\Sv-222\221_field2.doc
Residential. Commercial. Industrial. Land Develooment
Jan 26 05 10:21a Benjamin Herbst (208) 325-8149 p.1
- Summit Structural Engineering
106 E. Park Street, Ste. 206
McCall, ID 83638
(866) 862-8148
(208) 634-8148
Fax (208) 634-4157
January 26, 2005 IVED
Sun Vista Development, Inc. JAS! 2 6 2005
P.O. BOX 1144
La Quinta, CA 92253 Y.
Attn: Rob Capetz�
Subject: Structural Observation — Chase Residence
Lot 46 @ The Tradition
La Quinta, CA
Dear Rob,
Per your request, we visited the subject job site on January 21, 2005 to perform a
structural observation. While we were at the job site, we found several omissions and
deviations from the plans. All missing items were installed and verified while we were at
the jobsite, and at that time we found the structure to be in general compliance with the
structural design concept.
If you have any questions, please give me a call.
Yours truly,
SUMMIT STRUCTURAL ENGINEERING
Benjamin Herbst, P.E.
BH
g:1My Documents120041 obfileslSv-221\221_fieldl (cert).doc
Residential. Commercial. Industrial. Land Development
4j=
TANDY'S
INSPECTION INC.
PO BOX 13766
PALM DESERT, CA 92255
SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717
PAGER 760.776.3339
TYPE OF INSPECTION PERFORMED
'SH a rP Wv-4IL�
SAMPLE INFORMATION
SUPPLIER
TICKET NUMBER MIX NUMBER SAMPLED AIR TEMP STEPPE SLUMP TIME IN MIXER
DATE
a.3 O
PHYSICAL ADDRESS
S -Z -18s (:f I >R6kQ-TGoUc,
LA 6?0c,,OA
PERMIT NUMBER
JOB � E+ , ` �
1L�1 kS t eS .
TYPE OF S��E
ARCHITECT
PROCESS C
ENGINEER
WELDERS NAME
GENERAL CONTRACTOq
.SUN V lS TA
SUBCONTRACTOR
W N I rt���
DESCRIPTION OF WORK INSPECTED
r=12 Ul7Dea S
G41 L LLA t (, ®N olk
e'4 -i6 civ C.D L&ALpcoEF
-
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE
BUILDING LAWS.
CC:
NSPECTORS SIGNATURE
INSPECTORS CERTIFICATION AGENCY AND NUMBER
SAMPLE INFORMATION
SUPPLIER
TICKET NUMBER MIX NUMBER SAMPLED AIR TEMP STEPPE SLUMP TIME IN MIXER
LOCATION
WELDING INFORMATION
PROCESS C
WELDERS NAME
CERTIFYING AGENCY AND CERTIFICATION NUMBER
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE
BUILDING LAWS.
CC:
NSPECTORS SIGNATURE
INSPECTORS CERTIFICATION AGENCY AND NUMBER
:j. ". ;:r is 0
Aj--amaIJw MZ ! ftoU 118 ■m
1i:. fit. MWB ! B Abbe) Mabe) Ha�astios
mmmmmmmmlml�m
vmmmmmmmlm�m
JUL-28-2005 07:54 PM
ER.TIFICATE OF F9
P
Project TIt1e�r
TION AND DIAGNOSTIC TESTING
- auuoer name
Plan Number
71 Bleph ne Sample Group Number
2.11h s
P. 02
Ing Signatures Da Sample House Number
irm:_C. �srdezesS HERS Provider:
Street Addreise: 6YGle City/StateRip: Lo 4lqra —i c/f ,Z�
Copies to: Builder, HERS ProvldQr
HERS RATER COMPLIANCE STATEMENT
The house was: &STested 0 Approved as part of sample testing, but was not tested
As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form
coI with the diagnostic Tested compliance requirements as checked on this form.
Distribution system Is fully ducted (i.e., does not use building cavities as plenums or platform retums In lieu
ducts)
Where Goth backed, rubber adhesive duct tape is installed, mastic and drawbands are used In combination
th cloth backed, rubber adhesive duct tape to seal leaks at duct connections.
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 8% Duct Leakage)
Duct Pressurization Test Results (CFM C 26 Pa)
Test Leakage Flow In CFM
If fan flow is calculated as 400cfm/ton x number of torts enter
calculated value here ;
If fan flow is measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow)
Check Box for Pass or Fail (Pass=6% or less)
THERMOSTATIC EXPANSION VALVE 9XV) or Commission
Measured
values
1
, b'**
17z1
/1�9
Yes ❑ No Thermostatic Expansion Valve (or Commission approved
equivalent) is Installed and Access Is provided for Inspection
Yes Is a pass
❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT
1.. ❑ Yes ❑ No ACCA Manual D Design requirements have been met
(rater has verified that actual Installation matches values in
CF -1 R and design on plan.
2. ❑ Yes ❑ No TXV Is Installed or Fan flow has been verified. If no TXV,
verified fan flow matches design from CF -1 R.
Measured Fan Flow =
U
eassl
aas Fail
0 ❑
Yes for both 1 and 2 is a Pass Pass Fail
,..0Z/19/2004 14:08 7754854 HEGGE ELECTRICAL
ELECTRICAL LOAD CALCULATION
CUSTOMER
SunWsta Dev. Lot# 46 TRADITIONS
DATE
May 20, 2004
SQUARE FEET
5,156
3
GD
1,500
1
15,468
DW
1,500
1
1,500
SMALL APPLIANCES
11500
2
1,500
MICRO
1,5003,000
1
OVEN
810001
11500
COOKTQI'-ELfiCTRXC
8,0008,000
COOKTOP-GAS
1,500
1
8,000
WASHER
1,500
0
1
0
DR1'.ER�ELECTRTC
5.000
11500
DRYER -GAS
1,500
1
p
5,000
FA,U
0
POOL FUTURE
5,000500
6,000
LANDSCAPE FUTURE
5,000
1
1
5,000•
TOTAL -KW
1
5,000
_
61,468
1st 10,000 KW
FERCEN'T
1KW
REMAINDER
100%
10,000 10,000
A/C COMPRESSORS LG
91000
40%
51,468 20,587
A/C COMPRESSORS SM27,000
5,000
3
100%
TOTAL
1
100 %
5,000
DIVIDED BY
240 V
62,587
260.78 AMPS
JSE
400 AMP SERVICE
3EGGE ELECTRICAL CONTRACTORS INC,
13-852 AVE. 45
NDIO, CA, 92201 .
'A. LIC# 748X71
IM HEGGE
PAGE 01
SINGLE LINE DIAGRAM
400 AMP SPLXr BUSS SERVICE
200 AMP SU13PANZL
90 AMP SUBPANEL BR i
I
1
I
LOCATED @ CASITA
4 CU TO GAS & WATER
I
I
I
CONDUIT PER I1D/ SCE
HEDGE ELECTRICAL CONTRACTORS INC.
83-852 AVE. 45
INDIO, CA. 92201
LIC# 748171
JIM HEGGE