Loading...
07-1386 (AR)ro �_ft, P.O. BOX 1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: • 07-00001386 Property Address: 78215 CLOUD VIEW WY APN: 770-032-014-53 -28019 - Application description: ADDITION - RESIDENTIAL Property Zoning: MEDIUM DENSITY RES Application valuation: 30888 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: VELASQUEZ JAMI 78-215 CLOUD VT LA QUINTA, CP/9 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 3� y ✓414 a 02 0`4- . ®®� Contractor: Applicant: Architect or Engineer: FIELDING CONSTRUCTION 25911 YANEZ TRAIL ROAD MORENO VALLEY, CA 92551 (951)243-1810 Lic. No.: 514066 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cla s: A B Li a No.: 514066 Date: � Contractor: - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the fallowing reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I— 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I.QPERA11T Date: 7/30/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section !/�37770)0 of the Labor Code Zfrthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cou ty to nter upon the above-mentioned 'property Ioff!%inspection �pu�rtp�ose/s/n. Date: 42(2 gnature (Applicant or Agent): 1 AVIV 10,121 fV. I,QPFRAI IT '.Application Number . . . . . 07-00001386 ------ ' Structure Information (2) ROOM/BATH ADDITION/V-NR/RES-3 [CONY] ----- Other struct info . . . . . CODE EDITION 2001/2005 # BEDROOMS 1.00 FLOOD ZONE NO --------------------------------------------------- IST FLOOR SQUARE FOOTAGE -------------=----------- 540.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee 291.00 Plan Check Fee 189.15 Issue Date . . . Valuation . . . . 30888 Expiration Date 1/14/08 Qty Unit Charge Per Extension BASE FEE 252.00 6.00 ---------------------------------------------------------------------------- 6.5000 THOU BLDG 25,001-50,000 39.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . 33.90 Plan Check Fee 8.48 . Issue.Date . . . . Valuation . . . . 0 Expiration Date 1/14/08 Qty Unit Charge Per Extension BASE FEE 15.00 540.00 ---------------------------=------------------------------------------------ .0350 ELEC NEW RES - 1 OR 2 FAMILY 18.90 Permit MECHANICAL Additional desc . Permit Fee . . . . 44.00 Plan Check Fee 11.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/14/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 6.50 Permit. . . . PLUMBING' Additional desc Permit Fee . . . . 49.50 Plan Check Fee 12.38 Issue Date . . . . Valuation . . . . 0 �* Application Number . . . . . 07-00001386 Permit . . . . . PLUMBING k1 Expiration Date 1/14/08 Qty Unit Charge Per Extension BASE FEE 15.00 ^3.00 6.0000 EA . PLB FIXTURE 18.00 1.00 7.5000 EA -PLB WATER HEATER/VENT 7.50 1.00' 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 ---------------------------------------------------------------------------- Special Notes and Comments (2) ROOM/(1) BATH ADDITION/V-NR/RES-3 (CONVENTIONAL]..2001 CBC, CPC, CMC, 2004 CEC, 2005 ENERGY. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. July 18, 2007 10:04:27 AM AORTEGA -------------------------------- ------------------------------------------- Other Fees . . . . . . ENERGY REVIEW FEE 18.92 STRONG MOTION (SMI) - RES 3.08 Fee summary. Charged Paid Credited ------------------------------------- Due -------------------- Permit Fee Total 418.40 .00 .00 418.40 Plan Check Total 221.01 .00 .00 221:01 Other Fee Total 22.00 .00 .00 22.00 Grand Total 661.41 .00 .00 661.41 I,QPFR1141T Comments $1,000.00 + 420.20 = 2 money orders At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 540 S.F. or $1,420.20 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Money Order/Washington Mutual Bank Check No. 4599968058,06 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted,by Sh Signature ilvrey Payment Recd , $1,420.20 NOTICE: Pursuant to Government Code Section 66020(d)(1), %is poll serve to notify you that the 9"ay approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building .Permit Application and Tracking Sheet Permit # 01. 1.39 Project Address: v Owner's Name: U �Z A. P. Number: O,, fou • bt Address: C�lll� Legal Description: _Iasi ` City, ST, Zip: CA I Contractor: Telephone: Address: Project Description:Tul City, ST, Zip: Telephone: State Lic. 41: City Lic. #: Arch., ngr., Designer: Address: Z� CC`RMO OT -7 City, ST, Zip: 4 -as Telephone: 2 I Construction Type: V Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: - Sq. Ft.: #Stories:�G # Units: Telephone # of Contact Person: Estimated Value of Project:., APPLICANT: DO NOT WRITE BELOW THIS LINE Submittal Req'd Recd TRACKING _ PERMIT FEES Plan Sets Plan Check submitted iliq Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading. plan 2°" Review, ready for rrectio Electrical Subcontactor List Called Contact Person I'S p Plumbing Grant Deed Plans picked up S.M.I. . H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for cor Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees To rmit Fees 11 ,_ k�z APR 2 4 2007 U By I TITLE 24 REPORT I Title 24 Report for: Velasquez Residence Cloud View Way La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION � 0 Date: 0A2�—�- 6/19/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has. approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 6 HVAC System Heating and Cooling Loads Summary 8 Room Load Summary 10 EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R VgIasallez Rpsirlence [] Single Family ❑ Addition Total Conditioned Floor Area: 6/19/20n7 Project Ti le ❑ Multi Family ❑X Existing + Add/Alt Date Cloud Vievt Wa; l a Quinta Building Front Orientation: (NW) 315 deg Raised Floor Area: Project Address ft2 Fuel Type: Building Permit # Insu-form, InC_ 2,115 ft2 (760) 779-0657 Documentation Author Average Ceiling Height: 8.0 Telephone plan Check/Date Compr ceMethod Avg. U: 0.87 Number of Dwelling Units: Climate Zone Field Check/Date 9.1% Avg. TDV Standard Proposed Compliance BUILDING ZONE INFORMATION kBtu/sf- r) Design Design Margin Space Heating 4.33 4.13 0.20 Addition Living Zone Space Cooling 119.30 109.64 9.67 —n/ n/a Fans 16.17 14.88 1.29 Domestic Hot Water 11.17 12.55 -1.38 Pumps 0.00 0.00 0.00 Totals 150.98 141.20 9.78 Percent better than Building Type: [] Single Family ❑ Addition Total Conditioned Floor Area: 2,115 ft2 ❑ Multi Family ❑X Existing + Add/Alt Existing Floor Area: 1,575 ft2 Building Front Orientation: (NW) 315 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,115 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 192 ft2 Avg. U: 0.87 Number of Dwelling Units: 1.00 Ratio: 9.1% Avg. SHGC: 0.70 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Addition Living Zone San 439 1,575 x$00 n 965 rnnditioned—_ Setback— 074 Conditioned Sethack 2 _2 —n/ n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt wall Wood— 176 0074 —B_19_ R-0 0 1.5 gn Wall Wood_ 100 - 0 074 R-19 R-00 X45_ An Wall WODd_ _16.0_ —0 074 —g_1.9_ —0 0 295 An Rnnf Wood— 540 n 025) R_119 R-0 0 18n 0 Rnof ui/ond 1 575 0 049 R_19 Gains Condition Y / N Status JA IV Reference Location / Comments Run Initiation Time: 06/1910714:12:10 Run Code: 1182287530 EnergyPro 4.3 by Energysoft User Number: 2655 Job Number: Page:3 of 11 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Velasquez Residence 6/19/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazina TVDe Comments -1- Window Front (NW) 74 0 01970 NERC_ 0 70 _NFRC_ -315_ -A0_ Fxistina_Dnuble Mtl uncoated Default McMinn Status 2 Window Right (SW) 40.0 0.870 NFRC 0.70 NFRC 225 90 Existing Double Mtl Uncoated Default Addition 3 Window Front (NW) 40.0 0.870 NFRC 0_70 NFRC 315 90 Existing Double Mtl Uncoated Default Living Zone 4 Window Left (NE) 40.0 0.870 NFRC 0_70 NFRC 45 90 RemovedDouble Mtl Uncoated Default Living Zone 5 Window Left (NE) 20.0 0.870 NFRC 0_70 NFRC 45 90 Existing Double Mtl Uncoated Default Living Zone 6 Window Rear (SE) 16.0 0.870 NFRC 0_70 NFRC 135 .90 Existing Double Mtl Uncoated Default Living Zone L Window Right (SW) 40.0 0.870 NFRC 0.70 NFRC 225 90 Existing Double Mtl Uncoated Default Living Zone 8 Window Right (SW) 12.0 0.870 NFRC 0.70 NFRC 225 90 Existing Double Mtl Uncoated Default Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 8.0 2.0 0- 2.0 ?.Q 5 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 4.0 4.0 2.0 _0. 9 2.0 7 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 New Addition Slab Perimeter 38 None No Insulation 26-A1 Existing Living Zone Run Initiation Time: 06/19/07 14:12:10 Run Code: 1182287530 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:4 of 11 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Velasquez Residence Rated Tank Energy Tank Insul. 6/19/2007 Project Title Cap. Condition Factor Standby R -Value Date Syst. (Btu/hr) HVAC SYSTEMS Status or RE Loss (%) Ext. Rinnai R -53E Large Gas No Pipe Insulation 1 165,000 0 New 0.82 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Addition Central Furnace 80% AFUE Packaged Air Conditioner 13.0 SEER New Setback Living Zone Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Duct Location Heatinq Coolinq Location Addition Ducted Ducted Attic Living Zone Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 New No 2.1 Existing No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rinnai R -53E Large Gas No Pipe Insulation 1 165,000 0 New 0.82 0.00% 0.0 -Slaadard Gas 50 g Ia or Less Small Gas No Pipe Insulation 1 X0.000 50 New X53 n/a_ n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name:�ST Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form, Inc. Address: clAtZo Address: 41-921 Beacon Hill, Suite A UK U I NTS, COIN, Palm Desert, CA 92211 Telepho 0 ZI Lic. #: CI oO(nTelephone: 760 779-0657 o ignatu )It (d te) (signa re) (date) Enforcement Agency Name: Title/Firm: �p Address: STAMP P Telephone: (signature) (date) I EnerovPro 4.3 by EnergvSoft User Number: 2655 Job Number: Paae:5 of 11 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). ❑ ❑ ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:6 of 11 It Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1816 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 11 iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE . Velasquez Residence 6/19/2007 SYSTEM NAME FLOOR AREA Addition 540 Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 64.8 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 44.4 Total Output (sgft/Ton) 270.0 Air System CFM per System 930 Airflow (cfm) 930 Airflow (cfm/sqft) 1.72 Airflow (cfm/Ton) 465.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent 1, CFM I Sensible 1,293 13,179 1,356 199 7,116 0 2,344 913 0 0 0 0 0 0 0 0 0 2,344 913 17 867 1 356 8 941 Carrier 48G PO2404031 +VS 14,171 9,131 35,000 Total Adjusted System Output 1a,171 9,131 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 of 69.1 of 104.4 of 104.4 of O Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 103.5 of 930 cfm ROOMS 69.1 OF 70.0 of Return Air Ducts I SYSTEM PSYCH 11.0 / 77.6 of Outside Air 0 cfm 80.4/70.0 of 80.4 / 70.1 of 66.1 / 65.2 of Supply Fa 930 cfm Cooling Coil 66.1 / 65.2 of Supply Air Ducts Fan 68.4 / 66.0 of 65.1% R.H. ROOMS 78.0 / 69.3 of �N Return Air Ducts `S I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:8 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY --7] PROJECT NAME DATE Velasquez Residence 6/19/2007 SYSTEM NAME FLOOR AREA Living Zone 1,575 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 56.5 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sgft) 38.1 Total Output (sgft/Ton) 315.0 Air System CFM per System 2,210 Airflow (cfm) 2,210 Airflow (cfm/sgft) 1.40 Airflow (cfm/Ton) 442.0 Outside Air (%) 0.0 Outside Air (cfmisgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 2,007 24,082 2,422 631 23,125 0 5,681 3,989 0 0 0 0 0 0 0 0 0 5,681 3,989 35,47473[77772 422 31 102 HVAC EQUIPMENT SELECTION Existing 37,875 19,168 89,000 Total Adjusted System Output 37,875 19,168 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK - Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 68.3 of 68.3 of 106.10F Supply Air Ducts Outside Air 0 cfm 104.4 of Supply Fan Heating Coil 2210 cfm ROOMS 70.0 of 68.3 of i 11.0 / 77.6 of Outside �� 0 cfm 80.4/68.7 of 1% Return Air Ducts N ROMETRICS (Airstream T RnA/rA7OF Ann/RRROF r—q RdA/R'idOP Supply Fan Cooling Coil 2210 cfm Supply Air Ducts 66.7 / 64.2 of 60.5% R.H. ROOMS 78.0/68.0 of Return Air Ducts I EnergvPro 4.3 by EnergvSoft User Number: 2655 Job Number: Page:9 of 11 1 IROONI LOAD SUMMARY PROJECT NAME Velasquez Residence DATE 6/19/2007 SYSTEM NAME Addition FLOOR AREA 540 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 1,293 13,179 1,356 1,293 13,179 1,356 199 7,116 PAGE TOTAL 1 1,293 13,179 1,356 199 7 116 TOTAL 1 1,293 13,179 1,356, 199 7,116 EnergyPro By EnergySoft User Number: User Job Number: Page:10 of 11 ROOM LOAD SUMMARY PROJECT NAME Velasquez Residence DATE 6/19/2007 SYSTEM NAME Living Zone FLOOR AREA 1,575 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Living Zone Existing Living 1 2,007 24,082 2,422 2,007 24,082 2,422 631 23,125 PAGE TOTAL 1 2,007 24,082 2,422 631 23,125 TOTAL 2,007 24,082 2,422 631 23,125 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 11