Loading...
07-0583 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description „t Property Zoning: ~� Application valuation: �} Applicant: Tiht °F �Q�w BUILDING & SAFETY DEPARTMENT . BUILDING PERMIT _ 407'00000583- - 51525 AVENIDA JUAREZ 773-042-026-13 -000000- ADDITION - RESIDENTIAL MEDIUM DENSITY RES -51425 Architect or Engineer: Lic. No.: --------------- ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I a licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business a Professionals Code, and my License is in full force and effect. License Class: B CIO Wcense 46198 .�. 'f9 CDate'3 Z� Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500) .: 1 _ 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: MORRIS RICK 51525 AVENIDA JUAREZ LA-QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/22/07 Contractor: D W A &' M CONSTRUCTION P.O: BOX 366R n LA QUINTA, CA 92247 MAR 2 J 2007 (760)564-4832 ' Lic. No.: 746198 ClOFLAA...._ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:. Carrier STATE FUND Policy Number 0009232-2007 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to bec a ect to the workers' compensation laws of California, and agree that, if I should becom subjesubjct to the the compensation provisions of Section 2 0 370000 of the Labor Code, I shall i thwith comply wifMthose provisions. Date:d��a�`� Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abov information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building nstruction, and hereby authorize representatives ofthis county to enter upon the above-mentioned property f nspection purposes. Date:�� -Signature (Applicant or Agent): Application Number . . . . 07-00000583 Permit . . . . . . .PLUMBING LQPERAIIT_-- 'Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 423.50 Plan Check Fee 275.28 Issue Date Valuation''. 51425 Expiration Date 9/18/07 Qty Unit Charge Per Extension -* BASE FEE 414.50" 2.00 4.5000 ---------------------------------------------------------------------------•- THOU BLDG 50,001-100,000 9.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 41.51 Plan Check Fee 10.38 Issue Date Valuation . . . . 0 Expiration Date 9/18/07 Qty Unit Charge Per Extension BASE FEE 15.00 686.00 .•0350 ELEC NEW RES - 1 OR 2 FAMILY 24.0.1 125.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 2.50 Permit . ... GRADING'PERMIT - Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 9/18/07 Qty Unit Charge Per Extension ----------.------------------------------------------------------------------ BASE FEE 15.00 e Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 52.50 Plan Check Fee 13.13 Issue Date Valuation 0 Expiration Date 9'/18/07 Qty 'Unit Charge Per Extension BASE FEE 15.00- 5.001.00 1.009.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . . . . .PLUMBING LQPERAIIT_-- ------LQPRRN11T-- - Application Number 07-00000583 Permit . . . PLUMBING Additional desc . Permit Fee 76.50 Plan Check Fee .. 19.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/18/07 Qty Unit Charge -Per Extension BASE FEE 15.00 , 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB .LAWN SPRINKLER - SYSTEM 9.,00 4..00 3..0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 ---------------------------------------------------------------------------- Special Notes and Comments 686FT. CASITA ADDITION WITH 732 .SQ. SQ. FT. PATIO,125 SQ. FT. GARAGE.March 22, 2007 12:29:44 PM JJOHNSON ---------- ----------------------------------------------------------------- Other Fees . . . . . . . . ENERGY REVIEW FEE 27•.53 STRONG MOTION (SMI) - RES 5.14 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 609.01 .00 .00 609.01 Plan Check Total. 317.92 .00 .00 317.92 Other Fee Total 32.67 .00 .00 32.67 Grand Total 959.60 .00 .00 959.60 CERTIFICATE OF COMPLIANCE ���1Fscy Desert Sands Unified School District q 10 47950 Dune Palms Road Q a RMUDA DUNESCn O Date 3/28/07 La Quinta, CA 92253 RANCHO MIRAGE (� ; INDIAN WELLSDESERT No. 29319 (760) 771-8515 �� PALM LA QUINTA Shy �INDIO `^ o .v✓ Owner Rick Norris APN # 773-042-026-13 Address 51-525 Avenida Juarez Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Detached Guest House No. of Units I Lot # , No. Street S.F. Lot # No. Street S.F. Unit 1 51525 Avenida Juarez 686 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 , Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho ' mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Detached Accessory Structure ' EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 686 S.F. or $1,804.18 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/PDNB-Chuck Morris Check No. 099166 I Name on the check Telephone I Funding Residential By Dr. Doris Wilson .� Superintendent Fee collected /exempted by Yolanda Garcia Payment Recd $0.00 - $1,804.18 'e`er/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting cb, TITLE 24 REPORT Title 24 Report for: Rick & Shelly Morris 51-525 Avenida Juarez La Quinta, CA 92253 x .;. Project Designer: Stephen Nieto 78-120 Calle Estado Suite 206 La Quinta, CA 92253 760-564=4707 Report Prepared By: Stephen Nieto South West Concepts 78120 Calle Estado, Suite 206 La Quinta, CA 92253EDAT (760) 564-4707 ITY OF LA QUINT ILDING & SAFE A 1� � DEPT. FOR COR O vED I ACTION 3 22 a7 BY _ Job Number: 686 Date: �5, �� e� 11Op1 1. 2/16/2007 `` F The EnergyPro computer program has been used to perform the calculations summarized in this coQriance°report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 686 User Number: 5970 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1.R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 6 Form WS -SR Residential Kitchen Lighting 8 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 EnergyPro 4.3 by EnergySoft Job Number: 686 User Number: 5970 Certificate Of Compliance : Residential ❑ Multi Family n Existing + Add/Alt Existing Floor Area: (Part 1 of 3) CF -1 R Rick B&SheIV M Iorris 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 686 ft2 2/16/2007 Project Title Area: 118 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Ratio: 17.2% Avg. SHGC: 0.33 Number of Stories: Date _51-525 Avenida .ltjareZ_I a Qilonta Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .HVAC_Spstem 686 -6,517 100_ Conditioned -Setback- Project Address OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Building Permit # o jth West Cnrepts - Wall Wood_ 56- 0.06.9 R_21 --R--0.0 ---- A5 9.0 IX ❑Flew 09-A6 C Cita Iivin�$pace (760) 564-4707 Documentation Author Wall Wood 0-1169 R-21 R-0.0_ 0 9.0. ❑New 09=A6 Telephone plan Check/Date _EnergyPro CompliNrice Method 15Field Climate Zone Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin ❑ ❑ Space Heating 1.52 1.28 0.23 Space Cooling 77.37 79.59 -2.22 ❑ ❑ Fans 11.05 11.39 -0.33 Domestic Hot Water 24.14 20.29 3.86 Pumps 0.00 0.00 0.00 Totals 114.08 112.54 1.54 Percent better Building Type: Y Single Family ❑ Addition Total Conditioned Floor Area: 686 ft2 ❑ Multi Family n Existing + Add/Alt Existing Floor Area: 0 ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 686 ft2 Fenestration: Average Ceiling Height: 9.5 ft Area: 118 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Ratio: 17.2% Avg. SHGC: 0.33 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .HVAC_Spstem 686 -6,517 100_ Conditioned -Setback- 2 _n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wa11 Wood_ X87 -0-.Q6.9- R-21--R--0_Q_09.Q IN 1:1 New- MAR Casita Livinn Spam - Wall Wood_ 56- 0.06.9 R_21 --R--0.0 ---- A5 9.0 IX ❑Flew 09-A6 C Cita Iivin�$pace Wall Woosl_ 773_ X0.6.9 -R-21 _B=0-.0_ 9.0_ 90 EX ❑Nevi 09-A6 Casitalivmg-S pace /.all_ 1LV.ond_ 190 nn 064 R-91JR-nil2?5 gn New 09-A6 Casita Livinn SnacP Wall Wood 0-1169 R-21 R-0.0_ 0 9.0. ❑New 09=A6 -CasitalivinaSpace Roof -Wood-_6.8.6_ _0...025 R_ 1.8_ -JR-0a-��. ❑❑ clew 01-A18 C;isitaliving Sp ce ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ a❑ EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Paae:3 of 10 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Rick & Shelly Morris Project Title Date 2/16/2007 FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments _1_ _M[1dolet-Front fNl _20..0 -0_3A0 NFRC. 0.33 NFRC 0 -9.Q New 2 Window Front (N) 48.0 0.340 NFRC 0_33 NFRC 0 90 New AndamenRermasWeld acita Living Space Andersen Permashield Casita Living Space 3 Window Front (NE) 30.0 0.340 NFRC 0_33 NFRC 45 90 New Andersen Permashield Casita Living Space 4 Window Left (E) 20.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield Casita Living Space 2 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 3 Bug Screen 0.76 5.0 6.0 8.0 0.1 8.0 8.0 4 Bug Screen 0.76 4.0 5.0 8.0 0 1 8.0 8.0 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt Dist Len Hgt 1 Bug Screen 0.76 4.0 5.0 8.0 0.1 8.0 8.0 2 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 3 Bug Screen 0.76 5.0 6.0 8.0 0.1 8.0 8.0 4 Bug Screen 0.76 4.0 5.0 8.0 0 1 8.0 8.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 02116/07 16:00:27 Run Code: 1171670427 EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Page:4 of 10 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Rick & Shelly Morris 2/16/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 8.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst (Btu/hr) (al) Status or RE Loss (%) Ext A O Smith Water Products FPSE-40Small Gas No Pipe Insulation 1 40,000 40 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Stephen Nieto Address: 78-120 Calle Estado Suite 206 La Quinta CA 92253 Telephone: 760-564-4707 Lic. #: (signature) (d e) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Stephen Nieto Title/Firm: South West Concepts Address: 78120 Calle Estado, Suite 206 La Quinta, CA 92253 Telephone: 760 554-4707 a (signature) (date) STAMP EnergyPro 4.3 by EnergySoft User Number 5970 Job Number 686 Pam 5 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ R ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1: Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El El 11CF-6R Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Page:6 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or cther duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other Buildings on the ❑X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Page:7 of 10 Residential Kitchen Liqhtinq Worksheet WS -5R Rick & Shelly Morris 2/16/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. i Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. r High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 57w Com act Fluorescent Tri /Quad 4 in Yes X No 62.0 x 2 = 124 or Recessed Incandescent Yes . No X 60.0 x 1 = or 60 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 124 B: 60 COMPLIES IF A;-), B YES ® NO ❑ EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Page:8 of 10 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Rick & Shelly Morris 2/16/2007 SYSTEM NAME FLOOR AREA HVAC System 686 Number of Systems 1 Heating System Output per System 38,000 Total Output (Btuh) 38,000 Output (Btuh/sgft) 55.4 Cooling System Output per System 25,000 Total Output (Btuh) 25,000 Total Output (Tons) 2.1 Total Output (Btuh/sqft) 36.4 Total Output (sgft/Ton) 329.3 Air System CFM per System 895 Airflow (cfm) 895 Airflow (cfm/sqft) 1.30 Airflow (cfm/Ton) 429.6 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 14 547 :::;:;06 9,729 Bryant 556AN024-E/350MAV024040 15,744 7,781 38,000 Total Adjusted System Output 15 744 7,781 38,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am Vote: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Ti 26.0°F 69.1 OF 69.1 OF ® 109.0°F Outside Air 0 cfm Supply Fan 895 cfm 69.1 OF Heating Coil h Return Air Ducts 4 Supply Air Ducts 108.1 of ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 79.8 / 68.1 OF 79.8 / 68.2 OF 63.3 / 62.3 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 65.1 / 62.9 OF 895 cfm 58.9% R.H. ROOMS 79.8/68.1 °F 78.0 / 67.6 OF o,.4...._ A:_ M ... I EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 686 Page:9 of 10 ROOM LOAD SUMMARY PROJECT NAME Rick & Shelly Morris DATE 2/16/2007 SYSTEM NAME HVAC System FLOOR AREA 686 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Living Space All Conditioned Rooms 1 808 11,096 1,506 808 11,096 1,506 197 7,981 PAGE TOTAL 1 8081 11,096 1,506 TOTAL 1 808 11,096 1,506 197 7,981 197 7,981 EnergyPro By EnergySoft User Number: User Job Number: 686 Page: 10 of 10