05-2462 (SFD)h
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 UivfQ
Q� n�
Application Number: 05-00002462
Property Address: 51780 AVENIDA JUAREZ
APN: 773-155-001-24 -000000-
Application description: DWELLING - SINGLE FAMILY_ DETACHED
Property Zoning: COVE RESIDENTIAL
Application valuation: 101125
Applicant: Architect or Engineer:
Lic. No.: OOR SQUARE FOOT
MIA
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with ,
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B Li ,nse No.: 257274
Date: p Contractor: i_
OW -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I a mpt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and P essions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: at A
Lender's Address:
LQPERM1T
;k,
ARTMENT
IIT
Owner:
NEAL T BAKER ENTERPRISES
1875 BUSINESS CTR
SAN BERNARDINO, CA -92408
Contractor:
BAKER ENTERPRISE'S, NEAL T.
1875 BUSINESS CENTER DRIVE
SAN BERNARDINO, CA 92408
(909)884-7241
Lic. No.: 257274
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 11/03/05
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0440022527
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith cD with those provisions.
Date: j 5 GP Applicant:
WARNING:- FAILURE TO SECURE WORKERS' CO P SATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENH AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE OST OF. COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and he by authorize representatives
of this county to enter upon the above-mentioned property
for inns •btion purp
Date: Signature (Applicant or Agent)'�� ''c.i �it
Application Number . . . . . 05-00002462
Permit
. . .
BUILDING PERMIT
Additional
desc .
Permit Fee
. . . .
646.50
Plan Check Fee
420.23.
Issue Date
. . . .
Valuation
101125
Expiration
Date
5/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
2.00
-----------------------------------------
3.5000
THOU BLDG
100001-500,000
-------------------------
7.00
Permit
. . . MECHANICAL
Additional
desc . .
Permit Fee
52.50
Plan Check Fee
.13.13
Issue•Date
Valuation
0'
Expiration
Date
5/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00
9.0000
EA MECH
FURNACE <=100K
9.00
1.00
9.0000
EA MECH
B/C <=3HP/100K BTU
9.00 `
2.00
6.5000
EA MECH
VENT FAN
13.00
1.00
-----------------------------------------------------
6.5000
EA . MECH
EXHAUST HOOD
-----------------------
6.50
Permit
. . . ELEC-NEW RESIDENTIAL
Additional
desc .
Permit Fee
95.45
Plan Check Fee
23.86
Issue Date
Valuation . . . .
0
Expiration
Date
5/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1599.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
55.97
474.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
9.48
1.00
-------------------------------------------------------------
15.0000
EA ELEC
TEMPORARY POWER POLE
--------------
15:00
Permit
. . . PLUMBING
Additional
desc .
Permit Fee
. . . .
129.00
Plan Check Fee
32.25
Issue Date
. . . .
Valuation
0
Expiration
Date
5/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
10.00
6.0000
EA PLB FIXTURE
60.00
LQPERAIIT
i- - 4
Application Number
05-00002462
Permit . . . . . .
PLUMBING
Qty Unit Charge
Per
Extension
1.00 15.0000
EA PLB BUILDING SEWER
J15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.,0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
6.00 .7500
EA PLB GAS PIPE >=5
4.50
1.00 15.0000
---------------- ------------------------------------------------------
EA PLB GAS METER
15.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee
15.00 Plan Check Fee
.'00
Issue Date . . . .
Valuation
0
Expiration Date
5/02/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
1599 S.F. SFD PERMIT DOES NOT INCLUDE
BLOCK WALL, POOL/SPA OR DRIVEWAY
APPROACH
-
--------------------7-------------------------------------------------------
Other Fees . . .
. . . . ART IN PUBLIC PLACES -RES
20.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
42.02
DIF FIRE PROTECTION -RES
97.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
10.11
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged Paid Credited
----------
Due
---------------------------
Permit Fee Total
--------------------
938.45 .00 .00
938.45
Plan Check Total
489.47 •250.00 .00
239.47
Other Fee Total
2477.13 .00 .00
2477.13
Grand Total
3905.05 250.00 .00
3655.05
LQPERDIIT
4
. - -S;j�
F I LX
January 16, 2007
T-Vf .4 4 Q"
BUILDING & SAFETY DEPARTMENT
Mr. Mike Jiannoni
Neal T. Baker Enterprises
1875 Business Center Drive
San Bernardino, CA 92408
RE:. Building Permit Extension Request t'7_5_1_7_80_ Avenida Juarez.
Dear Mr. Jiannoni:
have reviewed your letter received January 12, 2007, requesting a time
extension for the single family residence being constructed'at the above address
under Building Permit #05-2462.'Our records indicate the following status on this
project.
Inspection status:
Permit issued: -
1/6/065
.Last successful inspection:
6/19/06 (Lath)
180 -day expiration date:
12/18/06
180 -day extension date:
6/18/07 .
Under the provisions of California Building Code Section 106.4.4, your request
is hereby granted. .
Because the Building Code specifies that "no permit shall be extended more than
once," please be advised that unless the project passes its next required
inspection on or before Monday, June 18, 2007, your building permit will expire
automatically.
Yours truly,
Building & Safety Manager
P.O. Box 1504 • LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253
(760) 777-7012 • FAX (760) 777-7011
R.�
eAn ZU-�ja- Xa 57-7 8 a �9�F
5-3.7y0 1941�5
,ca�� ,
�o
n r
i
/ . oS-ay&,;j
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road < B o
BERMUDA DUNES C"
Date 1/5/06La Quinta,: CA 92253 RANCHO MIRAGE
INDIAN WELLS
E ERT
No. 28017 (760) 771-8515 0> ? LA GUINTA
OINDIO
Owner Neal T. Baker APN # 773-155-001
Address Jurisdiction La Quinta
City Zip Permit #
Tract # , Study Area
Type Single Family Residence No. of Units 1
Lot # No. Street
Unit 1 .51780 Avenida Juarez
Unit 2
Unit 3
Unit 4
Unit 5
S.F. Lot # No.
1599 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Comments Certs #28016 & 28017 used for #2021500544 in the amount of $7163.52.
Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 1,599 S.F. or $3,581.76 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Bank of America - Mike Jiannoni
Name on the check
By Dr. Doris Wilson
Superintendent
Check No. 2021500544
Telephone
Funding Residential
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building DepartmenUApplicant Copy - Applicant/Receipt Copy - Accounting
G; •ear•
•�' Pin '�
^~r r
Fee collected /exem to
P Sh on ilvrey
Payment Recd
y $o:Iio°'
$3,581.76 Offer/Unde
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this
will serve to iny�� - ` ' testi t
notify Y� that � �Y approval period in which you may,protesf the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity
authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building DepartmenUApplicant Copy - Applicant/Receipt Copy - Accounting
April 18, 2006
City of LaQUinta
Dept. of Building & Safety
Re: Baker Houses
53740 Avenida Mendoza
51780 Avenida Juarez=
Pursuant to City. requirements, I have performed Structural Observations of the house framing for
the above properties to the following items of work.
1. Anchor bolt size and spacing
2. Shear wall sheathing, nailing and blocking
3. Header/beam sizes
4. Strapping at wall openings
5. Beam hardware
6. Holdowns
It has been observed that the above items of work have been performed in accordance with the
approved plans.
It is recommended that the city give its approval to the work and authorize the contractor to
proceed with .the remaining work.
QROFESS/?
tart �hbre�tibr 18932
ad 7 =�
JT,9T CMV �Q
F �F CALXE
n
TABLE OF CONTENTS TOC
Project Title.....:;.....: Date..10/08/05 15:34:13
Project. Address....... ******* ---------------------
La .Quint'a *v6.01* I
Documentation Author... ROBERT L.'EVANS ******* I Building Permit # I
R.EDE Energy Calculations
1357 Revelation Way. I Plan' Check / Date I
Redlands, CA 92374 I I
90.9-7'94=2111 I Field Check/ Date
Climate Zone....'....... 15
Comp.liance'Method...... MIC•ROPAS6 v6.0l'for 2001 Standards by Enercomp, Inc.
-------------
--------------------
I.: MICROPAS6'v6.01 File-DT1599R Wth-CTZ15892 Program-TOC
I', ..User#;MP0978 'User-REDS Energy Calculations. Run-NEIL T'.BAKER ENTERPRISES I
TABLE`0F CONTENTS
Report: Page
FORM CF-1R.............:.. 1
FORM MF-1R.................. 4
FORM C-2R..................... 7
HVAC SIZING..'... 10
CITY OFIAQU
NTA
BUILDING & SAFM DEPT
DOR-co
T'
RCONSTRUCTION
Dq E.J
By 7'
CERTIFICATE.OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project' Titl:e'.`. ....... Date..10/08/05 15:34:13
Project Address::.:.. *******
La QUint.a *x6:01* I
Documentation Author'...'. ROBERT L. EVANS. ******* I Building Permit # I
REDE Energy Calculations I .
1357 Revelation. Way 1 Plan Check / Date
Redlands, -,CA 92374 I I
909-.7.94-2111 1 Field Check/ Date I
Climate- Zone.:..........15 ---------------------
Compliance Method...... MICRO.PAS6.v6..0.1 for 2001.Standards by Enercomp, Inc.
----------------------------------------
1 MICROPAS6 x6.01 'File-DT1599R Wth-CTZ15S92 Program -FORM CF -1R 1
1. User#=MP0978 User-REDE Energy Calculations Run-NEIL.T BAKER ENTERPRISES .1
>>..'�i'.s :Szn'.' '.�a'.'b"`>�".c`st :.iel'etf' 3: ... r:n •�'`x �.s ..>r. :1.
". GENERAL • INFORMATION
Conditioned Floor.Area...... 1599 sf
Building Type .............. Single Family Detached
Construction Type ....: New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units..'. .1
Number of Stories... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage:.....:..... .12.1 %. of floor. area
;. Average. Glazing U -factor... 0.41 Btu/hr-sf-F.
'',Average 'Glazing.SHGC ........ 0.36
Average Ceiling Height..... 9.1 ft
BUILOING.SHELL,INSULATION
Component
Frame
Cavity
Sheathing' Total Assembly.
Type
Type
R�v.alud
R -value.
R-value'U-factor
Location/Comments
Wall_'-,
Wood:
R-13
R-0
R-13 0.088
TYPICAL .
RoofRadiarit n%a-
'R-38
R-n/a
'R-38 0:029
ATTIC
Door
n/a'
R-0.
R-n/a
R-0 0.330
ENTRY
S1abEdge.
n/a
R-0
R-n/a
F2=0.760 .TO
OUTSIDE
FENESTRATION
Over -
Area
U-
Interior
Exterior
hang/
Orientation'
(sf)
Factor
SHGC "Shading
Shading
Fins
Window _.•.Front.'(N)
77.0
0.400
0.350 Standard.
Standard
None
.Window
Front (N)
6:0
0.650
0.700 Standard
Standard
None
Window
Back (S)
35.5
0.400
0.350 Standard
Standard
None
Window
Left .(E)
20..0
•0.400 '0.350
Standard
Standard
None
Window
Right (W)
55.0
0.400
0..350.Standard
Standard
None
CERTIFICATE -"OF COMPLIANCE: RESIDENTIAL Page 2. .CF -1R
Project Title. Date..10./08/05 15:34:13
MICROPAS6 v6.01 File-DT159.9R Wth-CTZ15S92 Program -FORM CF -1R I
I. User#-MP0978 .•User -REDS Energy Calculations Run-'.NEIL.T BAKER ENTERPRISES I
SLAB SURFACES
T. --- -----------
Area
Slab Type (sf)
Standard Slab 1599
HVAC SYSTEMS
U------------
" Refrigerant Tested ' ACCA
Equipment: Minimum Charge.and Duct Duct Duct Manual Thermostat
.,'.Type r . „ . Ef•ficiency . Airflow Location R -value Leakage . D Type
Gas •.0.8.00 AFUE n/a Attic R-4.2 No No Setback
ACSplit 12.00 SEER No Attic R-4.2 No No Setback
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type: System Factor. {gal) R -value
----------------=-------------------------- -------- ------ ----------------
Storage Gas Standard. 1 0.62 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
**.* Items.in this section should'be documented on he plans, ***
***.'Insta.11ed to manufacturer and CEC specifications,. and ***
*** verified during plan check and field inspection. ***
This„is a. multiple orientation building with no ori.en.tatiori restrictions..
This printout is,kor the.front facing North.
This building incorporates a Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to 0.05, must be installed to cover the
roof trusses, rafters,.gable end walls and other vertical attic surfaces,
and must. meet attic. ventilation criteria.
REMARKS
CERTIFICATE OF•COMPLIANCE: RESIDENTIAL•• Page 3 CF=1R
---------------
____
Pro�eCt Title .. Date .10/08/05 15:39:13
MICROPAS6 v6.01 File-DT1599R Wth-CTZ15S92 Program -FORM CF -1R
I User#-MP0978 User -REDS Energy Calculations. Run -NEIL T BAKER ENTERPRISES I
COMPLIANCE• STATEMENT
This certificate of.compliance lists the building features and performance
spdci,fi.cations.... needed to comply with Title -24,. Parts 1 and 6 of .the
California Code of'Regula.tions, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
.submitted for a single building plan to be built in multiple orientations,
any. shading feature th at 'i s'. varied is indicated in the Special Features
.Mode li.ng'`Assumptions section. `
DESIGNER or'OWNER DOCUMENTATION AUTHOR
Nairie.=. DAVE ADRIAN Name..... ROBERT L. EVANS
Company.: DRAFTECH Company. REDE Energy Calculations
Address. Address. 1357 Revelation Way
Redlands, CA 92374
Phone....: 9 '-899- 22 Phone... 909-794=211
•License.
1 joS
l.�
Signed.. h ��Signed..'
. (date) (date)
-ENFORCEMENT .AGENCY
Name....
Title...
Agency:.
Phone....
.Signed.:
(date)
MANDATORY MEASURES.CHECKLIST: RESIDENTIAL Page 4 MF -1R
77
Project T.itle,.-..•.. Date..10/08/05 15:34:13
P•roject.Address::...... ******.*. =--------------------
La Quinta *v6.01*. I I
Documentation Author..: ROBERT L..EVANS Building Permit # I
REDE Energy Calculations I I
1357 Revelation Way.. I Plan Check'/ Date I
Redlands, CA 92374 I
909-794-2111 I Field Check/ Date I
Climate Zone... .... 15
Compliance Method.......:.MICROPAS.6 v6.01 for 2001 Standards by Enercomp, Inc.
------------
I .. MICROPAS6 v6..01 File-DT1599R Wth-CTZ15S92 Program-FORM.MF-1R
I User4-MP0'978 User -REDS Energy Calculations Run -NEIL T BAKER ENTERPRISES I
Note:• Lowrise'residential buildings subject to the Standards must contain these
measures regardless of the compliance.approach used. Items marked. with an
asterisk (*) may be superseded.by more stringent compliance requirements listed
on.the Certificate.of Compliance: When .this checklist is incorporated into the
Permit documents, .-the.features'noted shall be considered by .all parties as
minimum component performance specifications for the mandatory measures whether
they are abown•elsewhere in the documents cr on this checklist only.
BUILDING.ENVELOPE MEASURES
Design- Enforce-
er ment
*150(a): Minimum..R-19 ceiling insulation.
i5Q.(b): Loose fill insulation manufacturer's labeled R -Value:
*150.(c): Minimum.R-13.wal1insulation in wood framed.walls or
equi-valent U -factor in metal frame walls (does not apply
to";exter.ior' mass walls)
*150 (0).: 'Minimum .R=13 raised -floor.. -insulation in• framed -floor'.
150(1):. Slab edge insulation -.water absorption rate rib greater
than 0:3%, water vapor transmission rat.e.no greater than 2.0
perm/inch..
1.18: Insulation specified or, installed'meets insulation quality
standards.. Indicate type and form.
•116-17: Fenestration Products., Exterior Doors and Infiltration/
Exfiltration. Controls.
1.' Doors' and -windows between conditioned and unconditioned
:spaces -designed to limit.air leakage.
2 Fenestration products (except field fabricated) have
label with certified -U. -f actor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
.3. Exterior doors and windows weatherstripped; all.joints
and penetrations caulked and sealed.
150.(g): Vapor barriers mandatory in Climate Zones 14 and 16.
.only.
150(f)': Special infiltration.barrier'installed to comply with
Sec.. -151 meets Commission quality standards.
15.0(e)`:`.In$tallation.of.Fireplaces, Decorative Gas Appliance s
and Gas Logs
1. Masonry and..factbry-built fireplaces have:
a. Closeable metal or glass door
b. Outside. air intake with damper and control
c. Flue damper and control
2.. No.continuous burning. gas pilots allowed.
Ogg
NI W;P;J-
MANDATORY'MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R
Project Title. ..... Date..10/08/05 15:34:13
MICROPAS6'v6.01 File-OT15999Wth-CTZ15S92 Program -FORM MF -1R
I User.#-MP0978 'User-REDE Energy Calculations Run-NEIL'T BAKER ENTERPRISES I
--------------------------------------------------------------7----------------
SPACE CONDITIONING, WATER HEATING•AND.PLUMBING SYSTEM MEASURES
Design- Enforce-
er ment
110-113: HVAC equipment,. water,heaters, showerheads and
faucets certified by the Commission._.
150(h).: Heating and/or cooling loads. calculated in accordance
with ASHRAE, SMACNA or ACCA.
185Q(�i)�{;Setback thermostat -on all applicable. heating and/or
" co,o'ling"syst'ems}
150(j): Pipe and Tank insulation-
nsulation1.
l..Storage gas..water heaters rated with an Energy Factor
less than 0,.58 must be externally wrapped with insulation
having an installed.thermal. resistance of R-12 or greater.
2. First 5 feet of.pipes.closest to water heater tank, non -
recirculating systems, insulated -(R -A or greater):
3. Back-up,tanks:•for.solar system, unfired storage tanks,.or
other indirect hot water tanks have.R-12 external
insulation..or R-16 combined internal/external insulation.
4. All,buried.,or e'xposed,piping insulated in recirculating'
sections of'hot water system.
5: Cool'ing system piping below 55'degrees insulated.
6': Piping insulated between heating source and indirect
hot water tank..
*150 (in) Ducts and .Fans
•1. All -ducts and plenums: installed, sealed and in-
sulated,.to.meet t:he,requirements of the 1998 CMC sectons
601,.603i and,604, and standard 6 -3; -ducts insulated,to a
_'`,minimum: installed level .of R'-4'.2 or enclosed entirely
in conditioned,space. Openings shall be sealed
with mastic, tape, aerosol sealant,, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is.used to.seal openings .
greater. than 1/4 inch,.the combination of mastic and either
mesh
or .tape ,shall be. used. Building, cavities shall not be used
for
co'nveying'conditioned.air. Joints and seams of duct systems
and
their components shall not be sealed with cloth back rubber
addhesive.duct tapes unless such tape is used in combination
with
mastic' and drawbands .
2: Exhaust fari systems have backdraft or automatic dampers.
3.' Gravity ventilating systems serving conditioned space have.
either automatic•or readily accessible, mantivally
operated.dampers..
114:•Pbol and.Spa Heating Systems and.Equipment
1. System is certified with 78W, thermal efficiency, on-off
switch;' weatherproof operating:instructions, no electric
resistance heating and no pilot light..
2. System is• iristalled with:
a•. <At=.°least::36. inches. of pipe between filter ,and heater
for --futur,'esolar, heating.
b.. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and'a circulation
pump time switch.
MANDATORY.MEASURES CHECKLIST: RESIDENTIAL, Page
6 MF -1R
Project -Title............ Date..10/08/05
------------
15:34:13
I. MICROPAS6.v6.01 File-D.T1599R Wth-CTZ15S92 Program -FORM
MF -1R.
I User#-MP0978 User -REDS Energy Calculations. Run -NEIL T BAKER
ENTERPRISES I
115: Gas-fired centrale€urnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances.
";�`wtti' pilot < 150 Btu/hr) .-
LIGHTING MEASURES
-----------------
Design- Enforce-
er ment
150(k)l: Luminaires.,fo,r;•.general --lighting in•.kit•chens shall
have; 'lamps'with''an efficacy 6f 40 lumens/watt or greater
for general l.i.ghting in kitchens. This,general lighting
...,,.shall controlled by a switch on a readily accessible.:.
_be
lighting-cbntr.ol panel at an entrance to the kitchen..
.150(k)2.c`Rooms with a.shower or bathtub must have either at
least one. luminaire with lamps with an efficacy of 40
lumens/watt or .greater switched at the entrance to the
room or one.of the.alternatives to this requirement
allowed in See. .150(k)2..; and .recessed ceiling fixtures
are IC -(insulation cover) approved.DA
COMPUTER METHOD.SUMMARY
Page.7 C -2R
Date..10/08/05 15::34:13
Project Address.......::
*******
---------------------
1a.Quinta
*v6.01*
I.
Documentat'ion.Author... ROBERT L. EVANS
*******
I Building Permit # I
REDE Energy,Calculations
I I
13.57 Revelation
Way
I Plan Check / Date I
Redlands., CA.
92374
909-794-2111
I Field Check/ Date I
Climate Zone... .15:
----------------------
---- --------------
Compliance-Method ......
Compliance Method...... MICROPAS6 v6.01
------------------------------
for 2001
Standards.,by
Enercomp, Inc.
MICROPAS6 v6.01' File-DT159.9R
Wth-CTZ15S92
Program
-FORM C -2R I
I User#=MP0978' .User-REDE Energy Calculations
-------------------------------------------------------------------------------
Run
-NEIL
T BAKER ENTERPRISES I
_. MICROPAS6
ENERGY USE SUMMARY.
_
Energy Use:
Standard Proposed.
Compliance =
='.•(kBtu/sf-,yr)
--------------
Design
Design'
Margin =
_ .Space Heeating...............3.12
.3.92.
-0.80 =
- Space Cooling..::.:.....
39.84
39.00
0..84 =
Water Heating..........
15..09.
12.65
2.44 =
= North Total
58.05
55.57
2.48 =
= Space :Heating.•:.:........
3.12.
3:80
-0.68 =
Space .Cooling ...........
39.84
41.32
-1.48 =
- '.Water Heating.......:...
15.09
12.65'-.
2.44 =
= East Total'
58.05
57.77
0.28 =
- Space Heating.......... .
3.12
2.97
0..15 =
_ Space Cooling....:,':.:.
39.84
40.35.
-0.51 =
= Water•Heating.....:.::.
15.09
12..65
2.44 =
= South Total
.58.05
55.97"
2.08 =
= Space Heating.. ... ...
3:12
3.36
-0.24 =
_7. • -SpaceCooling....:...:...
39.84
41'.89
-2:05 =
Water H.eating....
15.09
12.65
2.44 =
= West Total
58.05
57.90
0.15 =
***:Building complies
with Computer
Performance
GENERAL
INFORMATION
Conditioned Floor. Area..,..
1599 sf
.
Building Type:,: .............
Single
Family
Detached
Construction Type .........
. New
Building Front.Orientation.
.Cardinal
- N,E,S,W
Number of D.welling.Units...
1
Number:of Building Stories..
1
.'Weather Data Type............
ReducedYear
COMPUTER METHOD SUMMARY Page 8 C -2R
Project Ti.tle.: Date..10/08./05 15:34:13
14ICROPAS.6 v6.01 File-DT15.99R Wth-CTZ15S92 Program-FORM.0-2R I
J.
5ser#.-MP0978 User-REDE.Energy .Calculations Run -NEIL T.BAKER ENTERPRISES I
Floor'Construction Type.... Slab.On.Grade
Number of..Buildng Zones... 1.
Conditioned Volume......... 14550 cf
Slab -On -Grade. Area........: :1599 sf
Glazing Percentage:.,....... 12.1 % of floor area
Average Glazing U-factor'...:.0.41 Btu/hr-sf-F
Average Gla.z.ing SHGC....... 0.36
Average Ceiling Height...... 9.1 ft
BUILDING ZONE* INFORMATION
Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit
HOUSE
Residence 1599 14550 1.00 Yes Setback 2.0 Standard No
OPAQUE SURFACES
Area U- :Insul Act Solar Form .3 .Location/
Surface (sf) factor R-val Azm Tilt Gains Reference Comments
HOUSE.
1 Wall 463 .0.088.13- 0 .90 Yes W.13.2X4 16 TYPICAL
2 Wa11 31.5 0.088'13. 180 90 Yes W.13.2X4.16 TYPICAL
3 Wall .196 0.088 13 180 90 No W.13.2X4.16 TYPICAL
41 Wall 81 0.088 13 90 90 Yes W..13.2X4 16. TYPICAL
S. Wall. 2.18 0.088.13. 90 90 No W.13.2X9.16 TYPICAL.
6 Wall.. 264 0.088 13 270 90 Yes W.13.2X4.16 TYPICAL
7 RoofRadiant 1599 .0.02938 n/a 0 Yes. None ATTIC
8 Door 24 0.330 0 0 90 Yes None ENTRY
9 Door 20 .0.330 0' 90 9.0 Yes None ENTRY
10 Door 20 0.330.0 .180 90 No None ENTRY
PERIMETER LOSSES .
Length F2 Insul Solar
Surface (ft) Factor.. R-val. Gains Location/Comments
HOUSE
11 S1abEdge• 190 0.760 R-0 No TO OUTSIDE
FENESTRATION SURFACES
--------------
Area U- Act Exterior Shade Interior Shade
Orientation. (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC
HOUSE
1 Window Front (N) 77:0. 0.400 0..350 0 90 .Standard/0.76 Standard/0..68
2 Window Front .'(N) 6.0*0.650 0.700 0 90' Standard/0.76 Standard/0.68
3 Window Back (S) 35.5 0.400 0.350 1.80 90 Standard/0.76 Standard/0.68
4 Window Left (E). 20:0 0.400.0.350 .90 90 Standard/0.76 Standard/0.68
5'Window Right (W). 55.0 0.400.0.350 270. 90 Standard/0.76 Standard/0.68
COMPUTER METHOD SUMMARY Page 9 C=2R
----------------------------------------
Project Title. Date..10/08/05 15:34:13
I. MICROPAS6 v6.01 File: DT1599R Wth-CTZ15S92 Program -FORM C -2R
I.'
User#-MP0978 .User-RE'E Energy Calculations .,Run-NEIL'T BAKER ENTERPRISES I
SLAB SURFACES
-------------
Area
Slab Type (sf)
HOUSE
Standard Slab 1599
s r HVAC . SYSTEMS
Refrigerant :.Tested ACCA
System Minimum Charge and Duct Duct Duct Manual Duct
Type'..Efficiency. Airflow Location R -value Leakage D Eff
HOUSE,
Gas 0.800 AFUE n/a Attic R=4.2 No No 0.•743
-ACSplit 1.2.0.0 SEER No . Attic R-4.2 No No 0.637
WATER HEATING.SYSTEMS
Number Tank External
in. Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Storage •Gas Standard 1 0.62 50 R- n/a
:SPECIAL. FEATURES AND MODELING ASSUMPTIONS.-
*** I•tems.in this section should be documented. on the plans; ***
***. installe'd.to manufacturer and CEC specifications, and ***
*** verified during.plan check and.field inspection. ***
.This is 'a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates:a.*Radiant Barrier. The radiant barrier must have
an emissivity less than or equal to G 05, must -be installed to cover the
roof trusses, rafters, gable.end walls and other vertical. attic surfaces,
and must -.meet attic ventilation criteria.
REMARKS
HVAC SIZING`. Page 10 HVAC
Proj'ect..,T,tie.... Date..10/08/05 15:34:13.
Proje.ct.Address..... ******* ---------------------
La Quinta *v6.01* I I
Documentation Author... ROBERT L. EVANS ******* I Building Permit # I
REDE'Energy Calculations I
•.1357'Revelation.Way I Plan Check / Date I
Redlands, CA 92374. I I
909-794-2.111 I Field Check/ Date. I.
.Ci:mate-1one............. 15 ---------------------
Compliance-'Method:....'. MICROPAS6 v6.01. for 2001 Standards by'Enercomp,.Inc.
----------------
MICROPAS6 v6.01 :File-DT1599R Wth-CTZ15S92 Program -HVAC SIZING
I User#-MP0.978 User -REDS Energy.Calculations 'Run-NEIL'T BAKER ENTERPRISES I
GENERAL INFORMATION
-------------------
Floor-Area..... .......... 1599 sf
Volume....... ............ 14550 cf
Front Orientation.......... Front Facing 0 deg (N)
Sizing Location............. PALM'SPRINGS
Latitude..... ..... ...33.8 degrees
Winter Outside Design..,..... 31 F
Winter InsideDesign........ 70 F
Summer Outside Design......... 113. F
Summer Inside.Design.-...... 78 F
Summer. Range.... 35 F
Interior Shading Used.. No.
Exterior Shading Used....:.. No..
Overhang.Shading Used...... No
Latent Load Fraction....... 0.30.
HEATING AND COOLING LOAD SUMMARY
-------------
Heating Cooling
Description .(Btuh) (Btuh)
Opaque.Conduction.and Solar ...... '13566 6065
Glazing Conduction ..... 3077 2762
Glazing Solar.. ................. n/a 3.317
Infiltration... .7977 5317
Internal.Gain.... n/a 2100
Ducts............ . 2462 1956.
Sensible Load............ .... 27082 21516
Latent Load.. n/a 6455
-----------------------
Minimum .Total Load 27082 ..27970
Note: The loads'-.shown.are only -one of the criteria affecting the selection
of.' HVAC equipment. Other relevant design factors :such as air flow.
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment., oversizing safety margin, etc., must also be
considered. It is the HVAC.designer's responsibility to consider all
factors when .selecting.the..HVAC equipment.
14VAC SIZING Page. 11 HVAC
Project Tithe.':".:::..... Date...10/08/05 15:34:13
---------------------------------- __________
I MICROPAS6 w6_01. File-DT1599R Wth-CTZ15S92 Program -HVAC SIZING
I User#-MP0978 User-REDE Energy Calculations .R,un-NEIL T BAKER ENTERPRISES I
GENERAL.INFORMATION
Floor. Ar.ea.'.. ..:.. 1599.sf.
Volume.......... 14550 cf
Front Orientation ............ Front Facing 9.0 deg (E)
.Sizing Location.... PALM SPRINGS
Latitude; .................. 33'.8 degrees
Winter Outside Design:..... 31-F
Winter Inside Design........ 70' F
`"Summer Outside Design.:',.. 113 F
Summer Inside Design::...,:.:. 78 F
Summer Range ................... 35.'F
Interior Shading Used...... No
Exterior .Shading .Used...'... No
Overhang Shading'Used..:.... No
Latent Load Fraction....:.. 0.30
HEATING AND COOLING LOAD SUMMARY
Heating Cooling
.Description. (Btuh) (Btuh)
Opaque Conduction and Solar....... 13566 6065
Glazing. Conduction.. ...... .3077` 2762
Glazing Solar, ........... n/a 4405
Infiltration ............. 7977 5317
Internal Gain ...................... n/a 210.0
Ducts. .............. 2462 2065
Sensible Load... ............ 27082. 22713
Latent Load. ................ n/a 6814
---------------------
Minimuin Total Load 27082 29527
Note:. The loads shown are .only one of the criteria affecting the selection
of HVAC 'equipment: Other re.levant design factors. such as air flow
requirements,' outside air,'outdoor' design temperatures, coil sizing,
.availability of. equipment, ouersizing safety -margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when -selecting the HVAC .equipment.
HVAC SIZING Page 12 HVAC
-------------------------------
Project Title........... Date..10/08/05 15:34:13
MICROPAS6'v6.01 File-DT1599R Wth-CTZ15S92 Program -HVAC SIZING
1. User#-MP097,8; User -REDS Energy Calculations Run -NEIL T BAKER ENTERPRISES I
GENERAL INFORMATION
-------------------
Floor Area.............:.... 1599 sf
.Volume ..................:... 14550 cf
Front Orientation.......... Front Facing 180.deg (S)
Sizing..Location'. PALM SPRINGS
Latitude ...................,33.8 degrees
..Winter Outside Design..*.... 31 F
;v
=Winter Inside Design. 7.0 =F
..:Summer Outside. 'Design:...:. 113 F ....
Summer Inside Design........ 78 F.
Summer Range ............... 35 F
Interior•Shading Used....... No
Exterior Shading Used....... No
Overhang Shading Used:...... .No
Latent Load Fraction:...... 0:30
= HEATING AND COOLING LOAD SUMMARY'
--------------
Note:.'The.loads.shown are. only one of .the criteria affecting the selection
of. HVAC equipment... .Other. relevant design -factors such as air flow
requirements;.outside air, outdoor design temperatures,coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It. is the HVAC designer's responsibility to' consider all
factors- •when selecting the HVAC equipment.
Heating
Cooling
.'Description..
(Btuh)
(Btuh)
Opaque Conduction.and Solar.......
13566
6065
Glazing Conduction..
3077
2762
Glazing Solar:.. . ...... ...•
n/a
3696
Infiltration ....:...::..........
7977
5317
Internal Gain.. ................
n/a
2100
Ducts:. ... ... ...
2462
1994
Sensible.Load..... .....:. .....
27082
21933
Latent .Load ...:.....:............
n/a
6580
Minimum Total.Load
27082.
28513
Note:.'The.loads.shown are. only one of .the criteria affecting the selection
of. HVAC equipment... .Other. relevant design -factors such as air flow
requirements;.outside air, outdoor design temperatures,coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It. is the HVAC designer's responsibility to' consider all
factors- •when selecting the HVAC equipment.
HVAC SIZING Page. 13 HVAC
Project Title:....:.... Date..10/08/05 15:34:13
MICROPAS6 v6.01 File-DT1599R :Wth-CTZ15S92 Program -HVAC SIZING
I. User4-MP0978 User -REDS Energy Calculations Run -NEIL T BAKER ENTERPRISES I
GENERAL INFORMATION
Floor.Area..... 1599 sf
Volume......... ......... 14550 cf
Front Orientation........... Front Facing 270 deg (W).
Sizing Location............ PALM SPRINGS
Latitude. 33.8 degrees.
Winter. Outside Design., .31 F
t'-.er Inside Design:. 70 F'
`Summer'`Oiitside .Des'ign...... 1,13'.F
Summer Inside Design....-_. 78 F
'Summer Range•.... ...... 35. F
Interior Shading Used...... No
Exterior Shading Used......: No
..Overhang Shading Used...:,... No
Latent Load Fraction...:.... 0.30
HEATING AND COOLING.LOAD SUMMARY
Heating Cooling
Description (Btuh) (Btuh).
Opaque.Conduction and Solar...... 13566 6065
Glazing; Conduction..... 3077 2762
Glazing Solar ............... n/a 4653
Infiltration. ..... 797.7 5317
Internal Gain........ n/a 2100
Ducts•.. .. ..... 2462 -2090-
Sensible Load......... 27082 22986
Latent,Load........................... n/a 6896.
Minimum Total Load 27082 29882
Note: The loads shown are only one of the criteria affecting the selection
of. HVAC. equipment: Other relevant, design factors such as air flow
requirements, outside air,.outdoor design .temperatures, coil sizing,
availability of 'equipment, oversizing safety margin,: etc., must also be
considered. It is the HVAC designer's responsibility to consider all,
'.factors when selecting the.HVAC .equipment.