Loading...
10-0734 (SFD)ME P.O. BOX 1504 78-495 CALLE TAMPICO +A QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: T4,4t 4 - 4 Qum' BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 10-00000734 Owner: 52060 AVENIDA JUAREZ HACIENDA GROUP INC. 773-211-034- - - 77935 CALLE TAMPICO #201 DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 COVE RESIDENTIAL 119171 [PD,, 1 Contractor: Architect or Engineer: CORONEL ENTERPRISES 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Lic. No.: 727199 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/28/10 Lf°� U 00 2010 W i..l ti OFfYOF LA A: ------------------------------------------------------------------------------------------------- r5. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of pe6uN that I am licens der pr i­sions _01chapte, 9 (commencing with Section 7000) of Division 3 of the tts d Profionals C e, and m icense is in full force and effect. License, lass: S lce a No.: 727199 Date: -ID Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5. by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I_ ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale ( Sec. 7044, Business end Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not.build or improve for the purpose of sale.). 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier UNITED INS Policy Number 238130742009 1 certify that, in the performance of the work for whit i permit is issued, I shall not employ any person in any manner so as to become subject t hew rkers' compensation laws of California. and agree that, hould come ubject to the work rs' compensation provisions of Section 3700 of the La r e, I hall f thwith compl wi those provisions. kateek-10-10 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN _ SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state th he above inform ' is orrect 1 agree to comply with all city and county ordinances and state laws relating t b ding onstruct n, a hereb authorize representatives of this county to enter upon the above-mentioned pr pe y for nspecti pur ses. Late: -q- 36 -16 Signature (Applicant or Agent): Application Number . . . . . 10-00000734 -- - - -- Structure Information 1,918SF DWELLING/VB/RES-3/CL-A [CONV] ----- Other struct info . . . . . CODE EDITION 2007/2008 # BEDROOMS 3.00 FIRE SPRINKLERS no GARAGE SQ FTG 461.00 PATIO SQ FTG 32.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 1918.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 709.50 Plan Check Fee 461.18 Issue Date . . . . Valuation . . . . 119171 Expiration Date 3/27/11 Qty Unit Charge Per Extension BASE FEE 639.50 20.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 70.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 106.35 Plan Check Fee 26.59 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/27/11 Qty Unit Charge Per Extension BASE FEE 15.00 1918.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 67.13 461.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.22 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/27/11 Qty Unit Charge Per Extension ----------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee 77.50 Plan Check Fee 19.38 LQPERMIT Application Number . . . . . 10-00000734 Permit . . . . . . MECHANICAL Issue'Date Valuation 0 Expiration Date 3/27/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA- MECH FURNACE <=100K 9.00 1.,00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 ' 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 ----------------------------------------- -6.5000 EA MECH EXHAUST'HOOD ---------------------------------- 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . 142.50 Plan Check Fee 35.63 Issue Date . . . . Valuation 0 Expiration Date 3/27/11 Qty Unit Charge Per Extension BASE FEE 15.00 11.00 6.0000 EA PLB FIXTURE 66.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 4.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 1.00 15.0000 EA PLB GAS METER• 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1,918SF DWELLING/VB/RES-3/CLASS A -FR [CONVENTIONAL] THIS PERMIT DOES NOT INCLUDE BLOCKWALLS OR DRIVEWAY APPROACH. 2007/2008 CALIFORNIA BUILDING CODES. September 28, 2010 8:40:25 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 BLDG STDS ADMIN (SB1473) 5.00 DIF COMMUNITY CENTERS -RES 74.00 DIF.CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 46.12 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC -. RES 892.00 COVE PRECISE PLAN FEE 100.00 DIF STREET MAINT FAC -RES 67.00 LQPERMIT Application Number . . . . . 10-00000734 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF TRANSPORTATION - RES 1930.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 1050.85 ---------- .00 -------------------- .00 1050.85 Plan Check Total 542.78 250.00 .00 292.78 Other Fee Total 4661.12 .00 - .00 4661.12 Grand Total 6254.75 250.00 .00 6004.75 LQPERMa TWT PO. BOX 1504 APPLICATION ONLY Building�1 78-495 CALLE TAMPICO Address,5Z' U (,l ��! e \ v.. t Z LA QUINTA, CALIFORNIA 92253 Adtjress`{'� 1M —1 ,-- /60 City No. No. Dw. 1 Stories , Units Zip Tel. State Lic. & Classif. r, ,f -, c, IE� City Lic. # Arch., Engr.,\_1S Designer Estimated Valuation } PERMIT Address Tel. o?Sol 60 -7 q -1\S C_.�&_ C__A_- S .\� '-1 �o SQ, iN-7 r,-1 ZiState a'ZS ?� Lic. # LICENSED CO RA TO ECLTjiAT10N I hereby ff' I am licensed un er p vi ' ns of Chapter 9 (commenci g w' Section 7000) of of the Business an P fes ions Code, and my license is force and effect. -OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ort mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. , I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCC. GRP. A.P. Number, �J' a\\ —O ZJf Legal DescriptioAb� - _XZ) Project Description Sq. Ft. c� Size \� No. No. Dw. 1 Stories , Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. o?Sol 60 Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure In A U j J I Iu 1: j tv -'i' L C IT'1111F LA:. trlTfa TOTAL c :1- REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE CERTIFICATE OF COMPLIANCE 4�� 21-Ebsc�° Desert Sands Unified School District 47950 Dune Palms Road Q< ° BERMUDA DUNES r RANCHO MIRAGE Date 9/30/10 !� La Quinta, CA 92253 INDIAN WELLS No. 30823 (760) 771-8515 dvDESERT > PALMOUINTA �INDIO yr3 Owner Coronel Enterprise 760-775-1234,: APN # 773-211-034 Address Jurisdiction La Quinta City Zip Permit # Tract # No. of Units 1 Type Single Family Residence Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 52060 Avenida Juarez 1918 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Payment Recd Unit 4 Unit 9 $5,696.46 Unit 5 Unit 10 Comments Ck amount = $5694.56 + cash of $1.90 = amount due At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 1,918 S.F. or $5,696.46 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Ish Coronel Name on the check By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by Sharof /?QWi Signature Check No. 007004939 Telephone 760-775-1234,: Funding Residential Payment Recd $5,696.46 Over/Under NOTICE: Pursuant to Government Code Section 66020(d)(1), this will 96rve to otify you that the 90 -day approval period in wtdch you may protest the fees or other payment identified above will begin to run from the date on whiph the uilding or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entkyaAorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting BUILDING ENERGY ANALYSIS REPORT PROJECT: Coronet Enterprises .Lot 20, Avenida Juarez La Quinta, CA 92253 Project Designer: South West Concepts 78-115 Calle Estado La Quinta, CA 92253 (760) 564-4707 . Report. Prepared by: Tim Scott • Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 AUG 0 6 2010 ' BY: o.613 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Date: FOR CONSTRUCTION 8/3/2010 DATE UW BY The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number., 6712 Run Code: 2010-08-03709:12:10 /D: C � J • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Coronel Enterprises Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/3/2010 Project Address Lot 20, Avenida Juarez La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,918 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 1,918 Radiant Barrier Cool Roof New Wall Wood Framed R-13 1,348 Ext=R-5.0 New Door Opaque Door None 20 New Slab Unheated Slab -on -Grade None 1,918 Perim = 212' New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (tM 20.0 0.400 0.35 4.0 none Bug Screen New Front (lAq 6.0 0.400 0.35 4.0 none Bug Screen New Front (W) 28.8 0.400 0.35 none none Bug Screen New Front (tM 33.4 0.400 0.35 none none Bug Screen New Left (N) 42.0 0.400 0.35 none none Bug Screen New Left (N) 52.0 0.400 0.35 none none Bug Screen New Left (N) 33.4 0.400 0.35 none none Bug Screen New Rear (E) 33.4 0.400 0.35 none none Bug Screen New Rear (E) 28.0 0.400 0.35 none none Bug Screen New Right (S) 7.3 0.720 0.59 none none Bug Screen New Right (S) 44.0 0.400 0.35 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status A/C 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.62 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2010-08-03T09:12:1 ID: Page 3 of 17 t C PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Coronel Enterprises Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/3/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic Reflectance = 0.65, Emittance = 0.75 shall be rated and labeled by the Cool Roof Rating Council in accordance with Section 10-113 of the standards. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Bryant 550AN060-EI311 JAV060090 includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System A/C 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System A/C 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-08-03T09:12:1 ID: Page 4 of 17 C� J PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Coronel Enterprises 1 ❑ Multi Family ❑ Existing+ Addition/Alteration $/3/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r - Space Heating 3.23 3.78 -0.55 Space Cooling 50.93 47.33 3.59 Fans 10.32 12.82 -2.50 Domestic Hot Water 16.74 15.17 1.57 Pumps 0.00 0.00 0.00 Totals 81.21 79.10 2.11 Percent Better Than Standard: 2.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tM 320 88 Fuel Available at Site: Natural Gas (N) 528 127 Raised Floor Area: 0 (E) 320 61 Slab on Grade Area: 1,918 (S) 528 51 Average Ceiling Height: 9.0 Roof 1,918 0 Fenestration Average U -Factor: 0.41 TOTAL: 328 Average SHGC: 0.36 Fenestration/CFA Ratio: 17.1% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 8/3/2010 Address 77-085 Michigan Drive Name Tim Scott J—'mj� City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the sp cifications, and with any other calculations submitted with this permit application, and recognizes that compliance us' g duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope s aling require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South West Concepts 5 Address 78-115 Calle Estado Name Steve Nieto V !W/0 City/State/Zip La Quinta, CA 92253 Phone (760) 564-4707 Signed License # Date Ene Pro 5.1 by EnemySoft User Number. 6712 Run Code: 2010-08-03T09:12:1 ID: Page 5 of 17 �J tri u CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Coronel Enterprises Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date $/3/2010 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm I Joint Appendix Tilt Status 4 Location/Comments Roof 1,918 0.026 R-38 901 0 New 4.2.1-A9 Entire Residence Wall 212 0.068 R-13 5.0 None 270 90 New 4.3.1-A3 Entire Residence Door 20 1.450 None 270 90 New 4.5.1-A1 Entire Residence Wall 401 0.068 R-13 5.0 None 0 90 New 4.3.1-A3 Entire Residence Wall 259 0.068 R-13 5.0 None 90 90 New 4.3.1-A3 Entire Residence Wall 477 0.068 R-13 5.0 None 180 90 New 14.3.1-A3 Entire Residence Slab 1,714 0.730 None 0 180 New 4.4.7-A1 Entire Residence Slab 204 0.730 None 0 180 New 4.4.7-A1 Entire Residence FENESTRATION SURFACE DETAILS ID T e Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 20.0 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Doors Entire Residence 2 Window 6.0 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 3 Window 6.7 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 4 Window 2.7 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 5 Window 33.4 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Doors Entire Residence 6 Window 10.0 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 7 Window 6.7 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 8 Window 2.7 0.400 NFRC 0.35 NFRC 270 New Double Tinted -Window Entire Residence 9 Window 15.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted-Oper Entire Residence 10 Window 6.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence 11 Window 15.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Open Entire Residence 12 Window 6.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence 13 Window 16.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence 14 Window 8.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence 15 Window 12.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted-Oper Entire Residence 16 Window 6.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 6.7 3.0 4.0 0.9 4.0 4.0 2 Bug Screen 0.76 2.0 3.0 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 1 0.761 1 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2010-08-03T09:12:1 ID: Page 6 of 17 F- -I L J 0 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Coronel Enterprises Building Type m Single Family ❑ Addition Alone ❑Multi Family ❑ Existing+ Addition/Alteration Date $/3/2010 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 33.4 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Doors Entire Residence 18 Window 10.0 0.400 NFRC 0.35 NFRC 0 New Double Tinted -Window Entire Residence 19 Window 33.4 0.400 NFRC 0.35 NFRC 90 New Double Tinted -Doors Entire Residence 20 Window 10.0 0.400 NFRC 0.35 NFRC 90 New Double Tinted -Window Entire Residence 21 Window 12.0 0.400 NFRC 0.35 NFRC 90 New Double Tinted -Window Entire Residence 22 Window 6.0 0.400 NFRC 0.35 NFRC 90 New Double Tinted -Window Entire Residence 23 Window 7.3 0.720 NFRC 0.59 NFRC 180 New Glass Block Entire Residence 24 Window 20.0 0.400 NFRC 0.35 NFRC 180 New Double Tinted -Oyer Entire Residence 25 Window 4.0 0.400 NFRC 0.35 NFRC 180 New Double Tinted-Oper Entire Residence 26 Window 20.0 0.400 NFRC 0.35 NFRC 180 New Double Tinted-Oper Entire Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-03T09:12:1 ID: Page 7 of 17 • I� CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Coronel Enterprises Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/3/2010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built A/C 1 Entire Residence 1,918 17,262 Totals 1 1,9181 01 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status A/C 1 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status A/C 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qt . TyDe Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RHEEM 41-R50N 1 Small Gas All Pipes Ins 40,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E 7 E w 2 Hot Water Piping Length ff o Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qt. HP Plenum Outside Buried ❑ ❑ ffooEl11 El EnergyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2010-08-03T09:12:1 ID: Page 8 of 17 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name oronel Enterprises Date 8/3/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySolf User Number: 6712 Run Code: 2010-08-03T09:12:10 ID: Page 9 of 17 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date oronel Enterprises 8/3/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 1816 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in.rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2010-08-03709:12:10 /D: Page 10 of 17 2oMANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date rone/ Enterprises 8/3/2010 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be.high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyP,o 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-03709:12:10 /D: Page 11 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name oronel Enterprises Date 8/3/2010 System Name A/C 1 Floor Area 1,918 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,208 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 21,864 1,998 734 24,843 Total Output Btuh 71,000 0 Output Btuh/s ft 37.0 1,087 1,221 Cooling System 0 0 Output per System 59,000 0 0 0 0 Total Output Btuh 59,000 0 1,998 0 Total Output Tons 4.9 1,087 1,221 Total Output Btuh/s ft 30.8 Total Output s ft/Ton 390.1 1 24,038 r 27,285 Air System CFM per System 2,025 HVAC EQUIPMENT SELECTION Airflow cfm 2,025 Bryant 550AN060-E/311JAV060090 38,830 14,362 71,000 Airflow cfm/s ft 1.06 Airflow cfmlTon 411.9 in Outside Air % 0.0% Total Adjusted System Output 38,830 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 14,362 Aug 3 PM 71,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions NO'HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,025 cfm 69 OF 69 OF 102 OF Heating Coil 102 OF MROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/66°F 79/66°F 60/59°F Outside Air c 0 cfm Supply Fan Cooling Coil 61 / 60 OF 2,025 cfm:................ .................... .... ..... 52.4% ROOMin 79/66°F _ 78/66°F EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 2010-08.03709:12:10 !D: Page 12 of 17 r: ROOM HEATING PEAK LOADS Project Name Coronel Enterprises Date 8/3/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Floor Area 1,918.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X 'X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = c = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof Attic 1,918.0 X 0.0260 44 2,194 R-13 Wall W(1"Foam 1,347.7 X 0.0675 44 4,006 Wood Door 20.0 X 1.4500 44 1,276 Double Tinted -Doors 120.2 X 0.4000 44 2,116 Double Tinted -Window 114.8 X X 0.4000 44 2,020 Double Tinted-Oper 86.0 0.4000 44 1,514 Glass Block 7.3 X X 0.7200 44 231 Slab -On -Grade perm = 212.0 0.7300 44 6,809 X X X X X X X X X X X X X X X X X X X X X X X. Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,918 X Area Ceiling another room 9.00 X 0.347 Height ACH Page Total /60] X AT 20,166 = 4,677 TOTAL HOURLY HEAT LOSS FOR ROOM 24,8 Ener Pro 5.1 by Energ Soft User Number. 6712 Run Code: 2010-08-03T09:12:1 ID: Page 14 of 17 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Coronel Enterprises ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Outdoor Dry Bulb Temperature Floor Area 1918.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: Ooaoue Surfaces R-38 Roof Attic R-13 Wall W/ 1 " Foam Wood Door R-13 Wall W/ 1 " Foam R-13 Wall W/ 1 " Foam R-13 Wall W/ 1 " Foam Orientation (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 1,918.0 0.0260 56.0 211.8 0.0675 33.0 20.0 1.4500 33.0 400.6 0.0675 23.0 258.6 0.0675 33.0 476.7 0.0675 26.0 418 0.0 41.8 280 0.0 41.8 113 0.0 21.0 315 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation 8/3/2010 112 OF 78 OF 34 OF Btu/hr 2,793 472 957 622 -5761 837 i 6,2581 Shaded Area X X X X X X X X X Unshaded GLF Area 21.0 + 10.7 21.0 + 0.0 21.0 + 6.7 21.0 + 2.7 21.0 + 33.4 21.0 + 10.0 21.0 + 6.7 21.0 + 2.7 21.0 + 15.0 X X X X X X X X X GLF = = = = = = = = = Btu/hr 9.3 41.8 643 6.0 41.8 126 0.0 41.8 280 0.0 41.8 113 0.0 41.8 1,395 0.0 41.8 418 0.0 41.8 280 0.0 41.8 113 0.0 21.0 315 Page Total 3,682 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 I Infiltration: 1.064 X 0.87 X 104.95 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,6641 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 104.95 X 0.00276 = 1,198 Air Sensible CFM ELA AW •, TOTAL HOURLY LATENT HEAT, RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Coronel Enterprises 8/3/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 1,918.0ft. Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF Btu/hr = 126 = 315 = 126 = 336 = 168 = 252 = 126 = 701 = 210 2,359 0.0 21.0 6.0 21.0 0.0 21.0 15.0 21.0 0.0 21.0 6.0 21.0 0.0 21.0 16.0 21.0 0.0 21.0 8.0 21.0 0.0 21.0 12.0 21.0 0.0 21.0 6.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Btu/hr 0 Shaded Area X X X X X X X X X1 GLF + + + + + + + + +1 Unshaded Area X X X X X X X X X1 GLF Btu/hr = 126 = 315 = 126 = 336 = 168 = 252 = 126 = 701 = 210 2,359 0.0 21.0 6.0 21.0 0.0 21.0 15.0 21.0 0.0 21.0 6.0 21.0 0.0 21.0 16.0 21.0 0.0 21.0 8.0 21.0 0.0 21.0 12.0 21.0 0.0 21.0 6.0 21.0 0.0 21.0 33.4 21.0 0.0 21.0 10.0 21.0 Page Total Internal Gain Btu/hr Occupants 4.0 Occupants. X 230 Btuh/occ. ' Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 104.95 X 34 = 3,288 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,864 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 104.95 X 0.00276 = 1,198 Air Sensible CFM ELA AW ,, TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I RESIDENTIAL ROOM COOLING LOAD SUMMARY I Coronel Enterprises ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Tem Surfaces DESIGN CONDITIONS Entire Residence Outdoor Dry Bulb Temperature 1,918.0ft' Outdoor Wet Bulb Temperature 78 OF Outdoor Daily Ranae: Orientation Date 8/3/2010 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = GLF = = = = c = = = 0.0 21.0 33.4 41.8 0.0 21.0 10.0 41.8 0.0 21.0 12.0 41.8 0.0 21.0 6.0 41.8 0.0 36.3 7.3 36.4 0.0 21.0 20.0 21.1 0.0 21.0 4.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Orientation Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = c = = = 0.0 21.0 33.4 41.8 0.0 21.0 10.0 41.8 0.0 21.0 12.0 41.8 0.0 21.0 6.0 41.8 0.0 36.3 7.3 36.4 0.0 21.0 20.0 21.1 0.0 21.0 4.0 21.1 0.0 21.0 20.0 21.1 Page Total 112 OF 78 OF 34 OF Btu/hr Btu/hr 1,395 418 501 251 266 421 84 421 3, Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu 1,600 Infiltration: 1.064 X 0.87 X 104.95 X 34 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21.8641 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 104.95 X 0.00276 = 1,198 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM a