11-0930 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00000930 Property Address: 81414 JACARANDA CT APN: 764-280-999-151 -300236- Application description: SOLAR Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 32000 Tu!t 4 4 Q" Applicant: Architect or Engineer: �111,II�as1NA„ 1�A► LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busi and Pr essiona s e, and my License is in full force and effect. - License Class: C10 License No.: 750184 Date: —1-11 Contracto I. DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001.: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: AL BISACCIA 81414 JACARANDA COURT LA QUINTA, CA 92253 Contractor: REC SOLAR INC 9301 IRVINE BOULEVARD IRVINE, CA 92618 (805) 54 0 -7613 Lic. No.: 750184 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/08/11 D ° t1 gy=p 08 2011 CITY OF LA QUINTA FINANCE rFPT. ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier ZURICH AMERICAN Policy Number WC938235403 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any man become to the workers' compensation laws of California, and agree that, ' I should beco a sub ct to the ers' compensation provisions of Section 3700 of the La r Code, I shall forthw h comply with those provisions. xDateT-8-0 Applic WARNING: FAILURE TO SECU KERS' CO ION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that formation is c agree to comply with all city and county ordinances and state laws relating building cons ruction, a hereby autho 'lswrepresentatives of thiscounty to enter upon the above-mentioned iroperty for inspection pur oses. _ CDateis% : • __b f L Signature (Applicant or Ag ri Application Number . . . . 11-00000930 Permit . . . SOLAR PERMIT Additional desc . Permit Fee 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation 32000 Expiration Date 3/06/12 L Qty. Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS ----------------------------------------------------------------------------- 3.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . 0 Expiration Date 3/06/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.50 ---------------------------------------------------------------------------- Special Notes and Comments 5.28kW SOLAR ARRAY - (22) 240 WATT REC J PANELS W/ (1) 5000W SMA INVERTER [458SF] 2010 CALIFORNIA ELECTRICAL CODE. September 7, 2011 2:48:37 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . .'. BLDG STDS ADMIN (SB1473) 2.00 Fee summary Charged Paid Credited ----------------- Due ---------------------------------------- Permit Fee Total 45.00 .00 .00 45.00 Plan Check Total 11.2.6 .00 .00 11.26 Other.Fee Total 2.00 .00 .00 2.00. Grand Total 58.26 .00 .00 58.26 LQPERMIT ENGINEER DRAFTER DESCRIPTION' ESTEVEZ PHOTOVOLTAIC SYSTEM (N) CONDUIT RUN (IN ATTIC) (N) ARRAY AR -01 287.15 SQ. FT (N) CONDUIT RUN (IN ATTIC) (N) ARRAY AR -02 107.71 SQ. FT (N) INVERTER WITH INTEGRATED DC DISCONNECT (INTERIOR GARAGE WALL) (N) CONDUIT RUN (EXTERIOR WALL) (N) PV PRODUCTION METER (EXTERIOR WALL) (N) AC DISCONNECT (EXTERIOR WALL) (E) SERVICE ENTRANCE AND MAIN PANEL (EXTERIOR WALL) USE: SINGLE FAMILY DWELLING OCCUPANCY: R -3/U CONSTRUCTION:V-B LEGEND (N) - NEW CONSTRUCTION (E) - EXISTING CONSTRUCTION JACARANDA COURT REC REC SOLAR, INC. CUSTOMER APPROVAL PLANS REVIEWED: CA CSLB C-10 9301 Irvine Boulevard #750184 2618 3 Faxine, 94CA 9215 -USA PROJECT FOREMAN BOM REVIEWED: SO MIKE REGMAW Phone (805)540.761 Fax (949)215 7778 � SITE PLAN SCALE: 1/16" = L' �CE�vE� TABLE OF CONTENTS PAGE # DESCRIPTION PV -01 SITE PLAN AUG 2 9 2011 PV -02 MODULE LAYOUT PV -03 MOUNTING DETAIL PV -04 ELECTRICAL DETAIL PV -05- SIGNAGE (E) RESIDENCE (E) PROPERTY LINE (E) DRIVEWAY CI BU SYSTEM INFORMATION ARRAY PITCH MAGNETIC TRUE ORIENTATION ORIENTATION AR -01 180 1710 1830 AR -02 180 2610 2730 4 I "�'�O A QUINTA �-- z AFETY DEPT. VED s``7 BY 1 Moa? VICINITY MA P SCALE: NTS 1) 5.28 KW SOLAR SYSTEM INSTALLED BY REC SOLAR CA CSLB C-10 #750184. 2) (22) REC 240PE (BLK) SOLAR MODULES MOUNTED FLUSH TO ROOF USING SNAPNRACK RACKING SYSTEM SERIES 100. SYSTEM WEIGHT: 3 LB/FT2. SYSTEMS ARE NON BALLASTED. 3) SINGLE STORY CONCRETE FLAT TILE ROOF AT 180 PITCH. 4) (1) SMA SB5000US INVERTER LOCATED INSIDE GARAGE ON SOUTH FACING WALL.. 5) CONNECT SYSTEM TO MAIN PANEL VIA 240V CIRCUIT BREAKER. 6) RUN CONDUIT IN ATTIC, PENETRATE GARAGE, RUN DOWNINTERIOR WALL TO INVERTER, PENETRATE EXTERIOR AND TERMINATE AT MAIN PANEL. 7) ROOF STRUCTURE: 2X4 PRE -FABRICATED TRUSSES @ 24 O.0 SPACING WITH 7'-6'.' MAX SPAN. BISACCIA RESIDENCE REV: 'A 81414 JACARANDA Cr, LA QUINTA, CA 92274 PV -01 APN# : 764-280-017 1 1 8/16/2011 r. o L=3 '7 ENGINEER RE ' 10'-11" DRAFTER DESCRIPTION ESTEVEZ PHOTOVOLTAIC SYSTEM (E) PVC VENT PIPE TO BE REROUTED DURING INSTALLATION MODULE LAYOUTSCALE: 3/16 =' 1' 23' 11'-10" 61 I { i C3-- _ 4' 8(NP) { { { { { i 5'_6" {{IIS;-\ ►�{\ �{{{{{{ CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED DATE BY SOLAR PANEL SNAPNRACK RACKING AND STANDOFF • ® AR -02 WEST ROOF ROOF INFO: MODULE NOTES: PARTIAL ROOF SECTION 2X4 PRE -FABRICATED TRUSSES @ 24" REC : REC240PE (BLF) SCALE: 1/2" - 1' O.0 SPACING WITH 7-8" MAX SPAN. 240W MODULES CONCRETE FLAT TILE 65.55" X 39.02" X 1.5" R CA CSLREC SOLAR, INC. CUSTOMER APPROVAL PLANS REVIEWED: BISACCIA RESIDENCE B C-10 9301 Irvine Boulevard REV: A #750184 Irvine, CA 92618 USA 81414 JACARANDA CT, LA QUINTA, CA 92274 PV -02 SQ (' „ Phone (805)540 -7613 Fax (9a9)z1s7ne PROJECT FOREMAN BOM REVIEWED: APN# : 764-280-017 8/16/2011 ENGINEER DRAFTER REGALADO ESTEVEZ DESCRIPTION PHOTOVOLTAIC SYSTEM (2) 5/16"-18 x 2-1/2" SS HCS (2) 5/16" SS SPLIT LOCK WASHER SNAPNRACK MODULE END CLAMP ---. SNAPNRACK CHANNEL NUT SNAPNRACK STANDARD RAIL SNAPNRACK STANDOFF CLAMP SS SPLIT LOC W LOCK WASHER 5/16"-18 x 2" SS HCS 5/16"-18 x 4" SS HLS (2.5" MIN OF THREADED SHANK INTO RAFTERS) 5/16" SS FLAT WASHER ---- (E) RAFTER - N� �� SNAPNRACK SPLICE ASSEMBLY MOUNTING DETAILSCALE: NTS SNAPNRACK MODULE MID CLAMP RAIL SPLICE INSERT 0 SNAPNRACK CHANNEL NUT SNAPNRACK RUBBER RAIN COLLAR INSTALL OVER FLASHING SNAPNRACK STANDOFF SHAFT SNAPNRACK STANDOFF BASE SEAL PENETRATION AND UNDER BASE WITH RAINBUSTER (OR EQUIVALENT) (E) ROOF DECKING RAIL SPLICE TOP (2) 5/16" SS SPLIT LOCK WASHER 5/16"-18 x 1" SS HCS SNAPNRACK RESIDENTIAL STANDOFF KIT (SIZE & SKU VARIES) FLASH POST Mir' ' STANDARD ROOF FLASHING FOR 1' DIAMETER VENT PIPE 0 _ qo. S1672 cic exp.06/13 NOTES: • LAG BOLTS MUST EMBED IN ROOF STRUCTURAL MEMBERS/RAFTERS • TORQUE ALL 5/16" HARDWARE TO 10 FT -LBS (120 IN -LBS) TORQUE • RAIL CAN MOUNT TO EITHER SIDE OF POST (UPSLOPE VS. DOWNSLOPE) • FOR UNEVEN ROOFS, USE 1" STANDOFF SHAFT SNAPNRACK RACKING SYSTEM SERIES 100: STANDOFF MOUNTING DETAIL CITY OF LA QU-INTA BUILDING & SAFETY DEPT. APPROVED ---__BY R E C REC SOLAR, INC. CUSTOMER APPROVAL PLANS REVIEWED: BISACCIA RES--iIDENCE CA CSLB C-10 9301 Irvine Boulevard' REV: A #750184 Irvine, CA 92618 USA 81414 JACARANDA CT, LA QUINTA, CA 92274 PV -03 SO ffr mtxe.Ec+uoo Phone(805)540-7613 Fax(949)215-7778 1 PROJECT FOREMAN BOM REVIEWED: I APN# : 764-280-017 8/16/2011 ENGINEER DRAFTER I DESCRIPTION REGALADO ESTEVEZ I PHOTOVOLTAIC SYSTEM NOTES TO INSTA R. 37.7 •INSTALL (1) 30A Open Circuit Voltage: (NEC 690.7) (1) 8 AWG THHN/THWN-2 GROUND 120/240 VAC BREAKER FOR P SINGLE PHASE SERVICE SYSTEM. METER #: IID (1) 10 AWG THHN/THWN-2 GROUND 00A MAIN AN�SR-130745 Short Circuit Current: (NEC690.8(A)(1)) 200A MAIN BREAKER • PV OVER CURRENT DC FUSING IN INVERTER FUSED PROTECTION DEVICE IS MAX. CURRENT < FUSES RATING < CONDUCTOR TO BE AS FAR AS POSSIBLE FROM THE MAIN OVER CURRENT 13.125 A < 15 A < 24.32 A PROTECTIVE DEVICE BREAKER RATING 30 AMP PV BREAKER (POINT OF CONNECTION) NEUTRAL BUS GROUND BUS FACILITYAIFER GROUND • 10 SS EXTERNAL TOM LOCK (STAR) WASHER #10.32. UY SS TIREAD-CUTTING SCREW ELECTRICAL DETAIL REC SOLAR: REC240PE (BLK) 3/4" EMT OR EQUIVALENT: Watts (2) 10 AWG TMHN/THWN-2 CONDUCTORS 37.7 (2) 10 AWG THHN/THWN-2 NEUTRAL Open Circuit Voltage: (NEC 690.7) (1) 8 AWG THHN/THWN-2 GROUND V 3/4" EMT OR EQUIVALENT: 30.4 (4) 10 AWG THHN/THWN-2 CONDUCTORS CONDUCTORS EXPOSED TO FREE AIR: (1) 10 AWG THHN/THWN-2 GROUND (4) 10 AWG RHW/USE-2 CONDUCTORS Short Circuit Current: (NEC690.8(A)(1)) (1) 10 AWG BARE COPPER GROUND SMA AMERICA : SBSOOOUS (240V) DC FUSING IN INVERTER FUSED 5000 WATT INVERTER & MAX. CURRENT < FUSES RATING < CONDUCTOR MANUAL FUSED DISCONNECT ASSEMBLY DEDICATED SYSTEM LOCKABLE kWh METER DISCONNECT INVERTE 13.125 A < 15 A < 24.32 A AC OUT BREAKER RATING O (22) REC SOLAR: REC240PE (BLK) MODULES IN (2) STRINGS OF (11) MODULES EACH DC IN 415 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE — _ 250V METER SOCKET SQUARED JUNCTION BOX MAX SERIES FUSING: 15A DU221R8 125A CONTINUOUS OR EQUIVALENT 3R, 30A, 120/240VAC CONNECT (1) TIGO MAXIMIZER TO EACH MODULE PANEL BUSBAR RATING MAIN BREAKER RATING WIRELESS COMMUNICATION BETWEEN GATEWAY FUSED, 4 -STRING COMBINER AND MAXIMIZERS AND LOAD RATED DC DISCONNECT (200 A) X (1.2) - (200 A) = 40 A COMM IN/OUT 120 VAC TIGO ENERGY GATEWAY GEC COMPLIANT WITH NEC ARTICLES 250 AND 690. ETHERNET IN` 6AWG BARE COPPER GROUND RUN OUTSIDE RACEWAY OR BAWG THHN IN CONDUIT CABLE (690.47, 250.30, 250.66, 250.64 & ANY OTHER APPLICABLE SECTIONS) ISP COMM COMM ROUTER OUT IN/OUT —MODULE FIGME OR RAIL 10 AWG BARE CU WIRE SS SET SCREW INCLUDED LAY -IN LUG TERMINAL AL/Cu DUAL RATED (TIN MTED CU) I 101M NOTE: REMOVAL OF PAINT IS NOT NEEDED PER UL 1703.11.3 AND 1703.11.4 TYPICAL MODULE GROUNDING DETAIL MODULE CHARACTERISTICS REC SOLAR: REC240PE (BLK) 240 Watts Open Circuit Voltage 37.7 V Open Circuit Voltage: (NEC 690.7) 42.0 V Max Power Voltage 30.4 V Short Circuit Current 8.4 Amps Short Circuit Current: (NEC690.8(A)(1)) 10.50 Amps R E Rr REC SOLAR, INC. ICA CSLB C-10 9301 Irvine Soule #750184 Irvine, CA 92618 SO MINEREGAIADo Phone (805)540-7613 Fax (949)215-. L•lO[Inaknw"41bnUbtbJWva.1094.1N6A_O1I116maaNaltaNaCl9n GmnanllO�OlouY. We14.AY.a :: dld1011 CUSTOMER APPROVAL PROJECT FOREMAN C1W OF LA C UNTA BUILDING & SAFETY DEPT. APPROVED TE BY LOW VOLTAGE CATS WIRE TIGO ENERGY MAXIMIZER MANAGEMENT UNIT (MMU) LOCATED NEAR CLIENTS ROUTER— RELAY DISCONNECT "PV SAFE" BUTTON TO DISCONNECT ALL UC CONDUCTORS ELECTRICAL CALCULATIONS PV SOURCE CIRCUIT (Isc) x (CONTINUOUS USE) x (ULTRA -IRRADIANCE) x (ALLOWABLE AMPACITY) X (TEMPERATURE DERATE) X CONDUCTORS (# COMBINED CIRCUITS) = MAX. CURRENT (CONDUIT FILL_ DERATE) = CONDUCTOR AMPACITY (8.4 A) X (1.25) X (1.25) X (1) = 13.125 A (40 A FOR #10) X (0.76) X (0.8) = 24.32 A INVERTER OUTPUT CONDUCTORS (Iop) X (CONTINUOUS USE) = MAX. CURRENT (ALLOWABLE AMPACITY) X (TEMPERATURE DERATE) X (CONDUIT FILL DERATE) = CONDUCTOR AMPACITY (20.8A)X(1.25)=26.0A (40 A FOR #10) X (0.76) X (1) = 30.4 A DC FUSING IN INVERTER FUSED FUSE RATING MAX. CURRENT < FUSES RATING < CONDUCTOR DISCONNECT AMPACITY 15 A FUSES 13.125 A < 15 A < 24.32 A AC OVERCURRENT PROTECTION BREAKER RATING MAX. CURRENT < BREAKER RATING < CONDUCTOR (BREAKER) AMPACITY 30A 26.0 A < 30 A < 30.4 A CEC 690.64: CURRENT < 120% PANEL BUSBAR RATING MAIN BREAKER RATING (BUSBAR RATING X 120%) - (MAIN BREAKER OF BUSBAR RATING RATING) = ALLOWABLE SOLAR BACKFEED 200 A, 200 A (200 A) X (1.2) - (200 A) = 40 A PLANS REVIEWED: BOM REVIEWED: BISACCIA RESIDENCE 81414 JACARANDA CT, LA QUINTA, CA 92274 APN# : 764-280-017 PV -04 REV: A 8/16/2011 W D n n D ENGINEER. DRAFTER I DESCRIPTION REGALADO EVrEVEZ '77—PHOTOVOLTAIC SYSTEM ELECTRICAL NOTES: " �/ 1. GROUNDING WIRE WILL BE BONDED DIRECTLY TO FACILITY GROUND 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2008 NEC 250 3. MODULE INTERCONNECTIONS WILL BE MADE WITH 10 AWG RHW/USE-2 WIRE. 4. ARRAY CONDUCTORS ARE SIZED FOR DERATED CURRENT PER STRING 8.4 AMPS SHORT CIRCUIT CURRENT 125% DERATING FOR EXTREME IRRADIANCE CONDITIONS (NEC 690-8 (a)) 125% DERATING, CONTINUOUS PHOTOVOLTAIC SOURCE CURRENT (NEC 690-8 (b)) 156% TOTAL DERATING (COMBINATION OF ABOVE) 13.10 AMPS TOTAL CAPACITY (AMPS TOTAL CAPACITY = STRING SHORT CIRCUIT CURRENT MULTIPLIED BY TWO ABOVE DERATES, 1.25 X 1.25 X SHORT CIRCUIT CURRENT) 5. INVERTER PROVIDES NECESSARY GROUND FAULT PROTECTION AS REQUIRED BY 2008 NEC 690.5 GROUND FAULT PROTECTION. 6. PHOTOVOLTAIC SYSTEM HAS CONDUCTOR BONDED TO GROUND IN INVERTER AS REQUIRED BY 2008 NEC 690.41 SYSTEM GROUNDING, AND 690.42 POINT OF SYSTEM GROUNDING CONNECTION. 7. WHERE DC PHOTOVOLTAIC OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING THEY SHALL BE CONTAINED IN A METALLIC RACEWAY OR ENCLOSURE FROM THE POINT OF PENETRATION TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS - 2008 NEC 690.31 (E) 8. USE UL APPROVED BONDING FITTINGS AT ALL CONDUIT/BOX JUNCTIONS. 9. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 10. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 SIGNAGE DC Disconnect -i WARNING - ElWitffihe Fiock Hazard DO NOT TRMINALS Terminals on nd Load sides may be ener ed Open Position. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL PLACEMENT DC DISCONNECT, COMBINER BOX WARNING - Electric Shock Hazard No user serviceable parts inside C ntact authorized servicer for assistance LABEL PLACEMENT AC DISCONNECT, COMBINER BOX, INVERTER WARNING - Dual Power Sources Second source is photovoltaic system LABEL PLACEMENT MAIN PANEL NEAR METER SYSTEM CHARACTERISTICS STICKER System Size 5.28 kW System Open Circuit Voltage 462 V System Operating Voltage 334 V Max Allowable DC Voltage 600 1 V System Operating Current 15.8 JAmps System Short Circuit Current 21.0 1 Amps LABEL: DC DISCONNECT OR INVERTER Solar Disconnect WARNING - Electrical ock Hazard DO NOT TO<"1 RMINALS Terminals on b i e and Load sides may be enerld in the Open Position. LABEL PLACEMENT AC DISCONNECT, NEAR BREAKER (FRONT OF PANEUDEAD FRONT) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL PLACEMENT AC BREAKER (INSIDE OR FRONT OF PANEL) REC Rrrrrc- SOLX (888) 657.6577 Toll Free—reaolar. • DO NOT OPERATE SOLAR SYSTEM BEFORE INSPECTION BY YOUR UTILITY • NO NET ENERGY CREDITS WILL BE EARNED • A FINE CAN BE LEVIED BY YOUR UTILITY • THIS TAG MAY BE REMOVED WHEN SOLAR SYSTEM PASSES UTILITY INSPECTION LABEL PLACEMENT AC DISCONNECT CAUTION: SOLAR CIRCUIT LABEL PLACEMENT CONDUIT, JUNCTION/PULL BOXES CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED DATE BY R E C REC SOLAR, INC. CUSTOMER APPROVAL PLANS REVIEWED: BISACCIA RESIDENCE CA CSLB C-10 9301 Irvine Boulevard REV: A ^ #750184 wine, CA 92618 USA 81414 JACARANDA CT, LA QUINTA, CA 92274 PV -05 SQ l MnmREr.AIADo Phone (805)540-7613 Fax (949)215-7778 PROJECT FOREMAN IBOM REVIEWED: I APN# : 764-280-017 8/16/2011 :: W-1 W D n n D 4:409wo, P.O. BOX 1504 t LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENTV 78-495 CALLS TAMPICO (7 60) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 TRANSMITTAL TO: UNG ❑VCA ❑ESGIL TODAY'S DATE: g- ? PROJECT ADDRESS: APPLICANT NAME: SUBMITTAL: 8fs"' ❑2"D BIN NUMBER: ❑ INCLUDED HEREWITH: EKANS ❑REDLINED PLANS UeRUCT ❑REDLINED STRUCT []TRUSS ❑REDLINED TRUSS []SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY []CORRECTION LIST []OTHER ATTENTION: �1 DUE DATE: �lvrL/12� 03 RD ❑4TH _ ❑57H PERMIT NUMBER: //_ q3c, []REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS [--]REVISED SOILS []APPROVED PLANS ❑APPROVED STRUCT []APPROVED TRUSS ❑APPROVED SOILS ❑CUSTOMER RESPONSES �; -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) []PUBLIC WORKS . ❑COVE CHECK (w/Application) LOCATION ON BOARD: LEFT MIDDLE RIGHT .SENT TO: �SY SV SH STRUCT/NON-STRUCT ASSIGN NON-STRUCTURAL TO: COMMENTS: LVVry.V 1✓1V%TMVGG1F1 VU. U1J1[Yll1;J wwwyaluen'gr.com: 71=-780 &ih Jacinto Dr Ste: E2 Randho: Mirage; :Ca; 92270 ph„ (760) 834-8860: faX (760) Letter of Transmittal To: City of La Quinta Today's Date: 9-6-11 78-495 Calle Tampico City Due Date: 9-5-11 La Quinta, CA 92253 Project Address: 81-414 Jacaranda Court Attn: Kay Plan Check #: 11-930 Submittal: ® 1St ❑ 4th ❑ . 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ® 1 Structural Plans ❑ Revised Structural Plans ® 1 Structural Calculations ❑ Revised Struct. Calcs ❑ Truss Calculations ❑ Revised Truss ❑ Soils Report ❑ Revised Soils Report ® 1 Structural Comment List ❑ Approved Structural Plans ❑ Redlined Structural Plans ❑ Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is not approvable, see attached structural plan check comment list. This Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ ® Per Your Request Rik-CETVED ❑ Approval ❑ At the request of: SEP U X11 City of La Quinta Building and Safety Department Plan Check Corrections Strums- . Bisaccia Residence — Roof Solar Panels Engineer: James A. Adams, SE 81-414 Jacaranda Court Plan Check No.: 11-930 (1st check) La Quinta, California Date: 9/6/201.1 1. Check existing trusses with worst case loading (multiple panel standoffs along the same truss with 8' of solar panels on each side of standoffs). If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Please incorporate requested corrections into plan sets and reprint. Plan Reviewer: John W. Thompson, P.E. Phone No.: 760-834-8860 Fax No.: 760-834-8861 1 m 0, R E C REC PEAK ENERGY [BLKI SERIES Peak PowerWatts-PMAX (Wp) ... ....... .... .... .... ......................................... ...................... 215 .-.............. 220 ...................... 225 ........ ......................... 230 ......... .I.- 235 ... ......... ......... 240 _........... _ ..... Watt Class Tolerance -PToL(W) ........ ............ 0/+5 I ..__................................................... 0/+5 0/+5 0/+5 ... I......................... 0/+5 0/+5 I _- :._ WattClassTolerance-PToL(0io) .............................................................................................................................................................................................................. 0/+2 0/+2 0/+2 0/+2 0/+2 0/+2 _..... Maximum Power Voltage - VMPP(V) 28.3 28.7 29.1 29.4 29.8 30.4 ........................................................................................................................................................................................................................ Maximum Power Current-IMPP(A) 7.6 7.7 7.7 7.8 7.9 7.9 ................................................................................................................................................................. Open Circuit Voltage-Voc(V) 36.3 36.6 36.8 37.1 374 377 .............-....... .... ...................................................................................... Short Circuit Current - Isc(A) 8.1 8.2 8.2 .............................. 8.3 ....... .............. 8.3 8.4 ............................................................................ Module Efficiency(%) .............................................................................................................................. 13.0 13.3 13.6 13.9 14.2 14.5 ........................................................................................................................................................................... Values at Standard Test Conditions STC (Air Mass AM 1.5, Irradiance 1000 W/mz Cell temperature 25 °C) Nominal Operating Cell Temperature (NOCT) 479 °C (*2°C) Temperature Coefficient of PMP, -0.46 %/°C Temperature Coefficient of Voc -0.32%/'C Temperature Coefficient of Isc 0.011 %pC r` ( ( FillDimensions65.55x39.02x1.5iZ vzor Area 17.76 ft �D Weight 39.6 lbs Certified according to UL1703, IEC 61215 and IEC 61730 REC is a leading vertically integrated player in the solar energy industry. REC is among the world's largest producers of polysilicon and wafers for solar applications, and a rapidly growing manufacturer of solar cells and modules. REC is also engaged in project development activities in selected PV segments. Founded in Norway, REC is an international solar company, employing more than 4,000 people worldwide. REC had revenues in excess of NOK 9 billion in 2009, approximately EUR 1 billion and approximately USD 1.4 billion. roar w C 0 N t_ IV CHARACTERISTICS 23SW MODULE 9 8 7 6 � 5 z 4 v 3 2 1 0 0 5 10 15 20 25 30 35 40 VOLTAGE (V) 1000Wsgm C 800 Wsgm 600 Wsqm 400 Wsqm 200 Wsgm EFFICIENCY 63 MONTHS WORKMANSHIP WARRANTY 25 YEAR POWER OUTPUT WARRANTY Cell Type 60 REC PE multi -crystalline cells 3 strings of 20 cells - 3 by-pass diodes Glass High -transparency solar glass with antireflection surface treatment by Sunarc Technology Backsheet Double layer high performance polyester Frame Black anodized aluminium Cable Radox 4 mm2 solar cables 35 in +47 in Connector Radox4mm2twist locking connector 10 years limited warranty of 90% power output 25 years limited warranty of 80% power output 63 months workmanship warranty Operational Temperature Maximum System Voltage Design Load (UL1703) Maximum Load (IEC 61215) Maximum Wind Speed Max Series Fuse Rating Max Reverse Current -40 ... +80°C 600V 75.21bs/ft2(3600Pa) 551 kg/m2 (5400 Pa) 122 mph (safety factor 3) 15A 15A Note! Specifications subject to change without notice. 9:, RCC REC Solar US LLC PO Box 3416 San Luis Obispo, CA 93403 USA www.recgroup.com SUNNY BOY 5000 -US / 6000 -US / 7000 -US / 8000 -US W o, o, 0. ,.wA X H UL certified • For countries that require UL certification (UL 1741/IEEE 1547) Efficient • 97% peak efficiency • OptiCoollm active temperature management system SMA {................. ............... .................. .. ............ I Safe Simple • Galvanic isolation • Patented automatic grid voltage detection* • Integrated DC disconnect switch SUNNY BOY 5000 -US / 6000 -US / 7000 -US / 8000 -US Versatile performer with UL certification The Sunny Boy 5000 -US, 6000 -US, 7000 -US and 8000 -US inverters are UL certified and feature excellent effi- ciency. Graduated power classes provide flexibility in system design. Automatic grid voltage detection* and an integrated DC disconnect switch simplify installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules—crystalline as well as thin-film. * US Patent US7352549B 1 r---------------------------------------------------------' r----------------------1 Efficiency curve SUNNY BOY 7000 -US !......................... Sunny Boy 5000 -US Sunny Boy 600 4U5 Sunny. Boy 7000 US Sunny Boy_8000-US Technical dot a 208 V AC 240 V AC 277 V AC 208 V AC 240 V AC 277 V AC 208 V AC 240 V AC 277 V AC 240 V AC 277 V AC Input (DC) 96 Max. recommended P.V-power (@ module STC) 6250 W 7500 W 8750 W 10000 W Max. DC power (@ cos pal) 5300 W 6350 W _ 7400 W 8600 W Max. DC voltage 1 r-600 V 600 V -DC nominal voltage 310 V 310 V I 310V I345 V MPP voltage range 250 V-480 = F--250 V --480 V 250 V - 480 V 300 V - 480 V Min. DC voltage /start voltage 250 V / 300 V 250 V / 300 V - 250 V Z. 300 V 300 V / 365-V Max. input current/ per string (at DC disconnect) 21 A/ 20A F 25 A / 20 A 30 A / 20 A 30 A / 20 k 36 A @ combined terminal LM A @ combined ter LMA@combinec1terminal 36 A @combined terminal - Number of MPP trackers / 1000 2000 3000 4000 5000 6000 7000 2.1i 1 / 4 (DC disconnect) 8 fuse -protected strings per MPP tracker Output (AC) - _AC nominal power -_ 5000 W 6000 W 7000 W7680 W 8000 W - Max. AC apparent power 5000 VA 6000 VA 7000 VA 8000 VA _Nominal AC voltage/adjustable 2081/• 240v/• 277v/• 2081/• 2401/• 277v/• 2081/• 2401/• 2771/• 240v/• 2771/• ° AC voltage range _- _ 183-2291 211 -2641 244-305 V' 183-229 V' 211 -2641 244-3051 183-229V 211 -2641 244-3051 211 -2641 244-3051 c =AC frequency; range 60 Hz; 59.3 - 60.5 Hz ` _60 Hz; 59.3 - 60.5 Hz 60 Hz; 59.3 - 60.5Hz 60 Hz; 59.3 - 60.5 Hz Max. output current 24 A 21 A 1A 29 A 25 A 22 A-1 32A I_ Power factor I 1 I 1 I 1 Phase conductorsconnection phases 1/ 2 1/ 2 1/ 1 1/ 2 1/ 2 1/ 1 1/ 2 1/ 2 1/ 1 1/ 2 1/ 1 Harmonicst <4% Efficiency _ _Max. efficiency _CEC efficiency Protection devices 3 DC reverse -polarity_ protection I• • • • _ AC short circuit protection • • • • Galvanically isolated /all pole sensitive monitoring unit • /- • /- • /-_ • /- Protection class / overvoltage category General data Dimensions (W / H / D) in mm(in) 470 / b 15 /.240 _(18.5 / 24 / 9) DC Disconnect dimensions (W / H/ O) in mm (in) 187z2_97/ 190_(7 / Packing dimensions (W / H / D) in mm (in) 390 /-580 / 800_(16 DC Disconnect packing dimensions (W / H / D) in mm (in) 1 _(23 / 16 / 1 1) o Weight / DC Disconnect weight 64 kgs(141.16� / 3.5 kgs(8 Ib) bb kg_(145 IbJ_/ 3�5 kgj8 Ib) a Packing weight/ DC Disconnect packing weight 67 kg�(147 IbJ-/ 5 kg=(9 lb) 69 kgs(152 IbJ,/ 4 kgy(9 Ib) - Operatingtemperature range (full power) -25 `C ... +45 'C_(-13 'F-... +113 'F) o _Noise emission (typical) 44 d8(A) 45 d8(A)46 dB(A) 49-d8(A) _Internal consumption at night0.1 W 0.1 W --0.l-W 0.1 W _Topoloav LF_iransformer LF transformer LF transformer I I LF transformer Cooling concept OptiCoolODtICOoI Opticool OptiCool o Electronics protection rating./ connection area NEMA 3R /NEMA 3R NEMA 3R /-NEMA 3R NEMA 3R /NEMA 3R NEMA 3R /NEMA 3R Features Display: text line—/ graphic - •/- •/- •/- •/- Interfaces: RS485 /Bluetooth — Warrany:l0/15/20years ___ -•/O/o •/o/o '570 a •/O/O Certificates and permits (more available on request) 74 UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B). CSA C22.2 No. 107.1-2001 •,Standard features_O-Optional features=not available - Data at nominal conditions a Type designation SB SOOOUS SB 6000US----1 I SB 7000US I SB 8000US E r---------------------------------------------------------' r----------------------1 Efficiency curve SUNNY BOY 7000 -US !......................... 98 96 — VN - 250 V DC -•• V„ •••• VH-480VDC rn; \ 9e.5 250 a80 '• l r.� 94 °l io 92 U• c 90 95.5 .3 88 ° v; -310VDC 86 a. �i 1000 2000 3000 4000 5000 6000 7000 2.1i Pay [Wl ;i CombiSwitch .� DC disconnect and W array combiner box COMBO -SWITCH www.SMA-America.com SMA America, LLC f 8 0 — VN - 250 V DC -•• V„ •••• VH-480VDC ° -O rn \ 9e.5 250 a80 '• l r.� CombiSwitch .� DC disconnect and W array combiner box COMBO -SWITCH www.SMA-America.com SMA America, LLC f 8 0 T190M energy Tigo Energy' Tigo EnergyTM Module Maximizer -ES Module Maximizer -ES (MM -ES) r Data Sheet W96 energy r tleCuh 18rinherE9 rnw YYFloMOfwM For residential, commercial and utility scale photovoltaic solar arrays, the Tigo EnergyTM Maximizer system optimizes the power output of each module (solar panel); delivers module - level data for operational management and performance monitoring; and provides the ability to deactivate the high voltage DC bus for safer installation, maintenance or fire fighting. Tigo EnergyTM Module Maximizers are key components of the system which reside at each module (one per solar module). The Module Maximizer provides data acquisition, communication to the Tigo EnergyTM Maximizer Management Unit, and energy harvesting control. The very small electronics footprint has been designed to minimize cost and maximize reliability. Tigo Energy Maximizer MM -ES is ideal for the European market and retrofit around the world. The Tigo Energy output optimization starts with dynamic module balancing - a Module Maximizer (patented) attached to each module manages the energy harvest and sends information to the Maximizer Management Unit for reporting and control. The Tigo Energy Serial Module Maximizer (MM -ES) connects in a series topology. MM -ES maintains best -in -class system conversion efficiencies. The Tigo Energy Module Maximizer includes a unique technology (patented) which greatly enhances the safety of a PV solar installation. As part of the Tigo Energy Maximizer system, this function can be activated with a safety button or via a remote management console. The system can be installed, maintained or approached by fire personnel without the i exposure to voltage levels typically in excess of 400 volts. The Tigo Energy Module Maximizer, is packaged in a NEMA3R enclosure (water and weather resistant), conforms to UL and IEEE safety standards. There are Module Maximizer options to fit any PV module, crystalline silicon or thin-film, regardless of output voltage or nominal power rating. ___�GLGREEN BUSINESS BAY AREA Tigo Energy'"' Module Maximizer -ES 1 Ask your PV Solar distribution partner for the Tigo Energy Module Maximizer pre- installed on many of their most popular framed solar panels for simple on-site system installation for your new or existing PV system. Also watch for modules that include the Tigo Energy technology fully integrated into the junction -box - available soon from leading PV module manufacturers. Module Maximizer -ES Technical Specifications ! Output Data (DC) Maximum output power MM-ES60 MM-ES90 Input data 12A 6A Input rated power 30OW 300W Maximum input DC voltage 18-60V 50-90V Peak Power tracking voltage 18-60V 50-90V Maximum input current 12A 6A ! Output Data (DC) Maximum output power 30OW 30OW Maximum over load current 12A 6A Maximum steady state current 12A 6A Nominal Voltage/range variable variable Maximum units per branch 250 250 Mechanical Data Operating temperature range -30'C +70'C Cooling Natural Convection Enclosure environmental rating IP -65, NEMA3R Features Compliance ®R- ( E per UL 1741 IEEE 1547.1 FCC part 15, class B EN 61000 Panel connector NEC 2008 compliant MC4 compatible (for retrofit) MC3 connectors Bus connector NEC 2008 compliant 40AMP Optimize the energy harvest of your PV system using the Tigo . Energy Maximizer to: • accelerate system payback; • maximize the power output of individual modules; • reconsider previously unfavorable projected rejected because of shade or orientation; • maintain best -in -class conversion efficiency; • manage the system with module -level data to minimize operational costs and keep the system at peak performance throughout its lifetime; • introduce an unprecedented level of safety for new and existing PV solar installations (patented); • simplify the balance -of -system design, especially for high Voc or thin-film modules. m M a m Tigo M Tigo Energy, Inc.03 P: +1.408.364.0150 1 F: +1.408.364.0160 W f 170 Knowles Drive, Los Gatos, CA 95032 U.S.A. energy www.tigoenergy.com contact@tigoenergy.com "A' ...,. energy Ticc Ene-gyT" Waximizer Ma-iagement Unit Tigo EnergyTM Maximizer Management Unit (MMU) Data Sheet I EMERGENCY iElD:19 For resioemiat -ymmEmial and utiity scale PV ar-ays, the Tigc EnergyT" �vaximizer Sys. -em optimizes pottier output per each mocule (solar sanel) delivers module -eve -1 data for operational rnanagementanJ performance monitoring; and provioes the ability to deac-ivate the high Nottage OC b -;E -or safer installation, maintenance or fire fighting. The Tigo Energy Maximizer Management _`rit (MMU) I,ommunica'es betwee:i the Module Maxi•nizers ===nd the Inverer, controls aroc:--_sE-es in real time and sends cats kl a remote server in orOE,- No alovv multple user to observe an i-)-eract with the monitoring syst:xn. _Each Tigc Ere -pe Maximizer systEm (:mterted) includas one MMU per praect, with the option of a second uni: for system nedunda-icy. The MMIj has a manual userintera•,e and LCD display -ioused iii -i a. NEM A3 enclosure for on: ite programming. The 'VMU mount near the inverter and -ommu-icate` wth each PV mod.ite in the systam, paovides managem.nt and control -unctions -or the nodue Mfaxim:.zers, and serves as a gateway -o the Data C3nte-. The rvaximizel Managenen- FUni: is pre-ccnfigurEd vOth CAT --5 Ethernet acmes ar d can 2hip with optional wi-f or cellular cor-municafon modules. The MVU can be used as a qualify ng! nve-ter and overall system perfcwnance rrorbtoring interface for legacy irstallatiDis. The MfJU inc nudes the Tigo EnergyTM PV -SAFE Dutto-r - a unbue onsite xfety feature ocated on the Mnt if -the Mmmzer Maragement Unit With one push of -the rev button, an onsite operator or evergency personnel can dea.tivae the -entire aray fcr maintanarce or emergenev purposes (paented).=V-=Zafe enables eac-i module to be el.;,-ricaly removed from the high voltage DC c3oirng lirnting the votaga exposur-eto the oper-carom voltag (Vcc) of a sngle module_ As part of the Tgo Energy Eystem, th =_ function can be activated with the safety button GREEN BUSINESS or via a -ema:e rnana-pment consolE. The system can be instafel, mai-raineJ or approachec BAY AREA by fire pnrsc nnel without the exposure to voltage Ievds typically n excess Df 400 volts. Tigo E®ergy, Inc. 117) Knowles Drive _os Ci3Ras, CEk 95[32 P. +1.408.3E4.01 ATCUOMINFwwa goeneNgyTeom Tigo Energy TM Maximizer Management Unit � Secure remote access to the MMU via the Tigo Energy MaxiManager software applications is available through any internet-enabled computer, with views available for system owners, installers, power plant operators and emergency services personnel. Simple, easy -to -understand graphics allow for quick analysis of the real-time output and historical performance of each system, and the ability to view and remedy system faults, error codes or alerts. Ask your PV Distribution partner for the Tigo Energy Maximizer Management Unit for your new or existing PV Systems. Maximizer Management Unit Technical Specifications Electrical Specification Single MMU supports 1 to 1000 Module Maximizers Communication (MMU to Data Center) Ethernet Wireless 802.11 b/a/g; WEP and WPA security Cellular modem Mechanical Specifications Dimensions (LXWXH) Weight Operating Temperature Regulatory Compliance North America Canada 245 x 150 x 80 mm 1000 gm -30 to +70'C EMI/EMC FCC PART 15 CLASS B; UL 60950 ICES -003 CLASS B t "- r Optimize the energy harvest of your PV system using the Tigo Energy Maximizer to: • accelerate system payback; • maximize the power output of individual modules; • reconsider previously unfavorable projected rejected because of shade or orientation; • maintain best -in -class conversion efficiency; • manage the system with module -level data to minimize operational costs and keep the system at peak performance throughout its lifetime; • introduce an unprecedented level of safety for new and existing PV solar installations (patented); • simplify the balance -of -system design, especially for high Voc or thin-film modules. co Tigo T. Tigo Energy, Inc. P: +1.408.364.0150 1 F: +1.408.364.0160 170 Knowles Drive, Los Gatos, CA 95032 U.S.A. energy www.tigoenergy.com contact@tigoenergy.com Bin.#Ld '^*. City of Quin' to Building a Safety. Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253- (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �l Project Address I L, I J -Qnd� C� - Owner'sName: A. P. Number: `�� -,280— co (7 Address: 9 61I1/ --.S 4if4,-Gr,/— Legal Description: City,ST, Zi p: qZZ7q Contractor: ��G v jG, � . Telephone: .�.'�.".��`-•:,::�,•���' Address: . q 3�- o Ii �%a C_ (v t1- Project Description: City, ST, Zip: �1 /�✓t L C Z6 /0 8 /U Telephone:a•>:<. +f��>LCv$'ii:}:iv?C4 f State Lia # City Lie. Arch., Engr., Designer: /j f r u j s (V --% v 4 Address: City, ST, Zip: Telephone:S::" State Lia ak: a<t>Y Name of Contact Person:Uni A ^J D eifv ��A IU ,k C- Construction Type: Occupancy: Project circle one): dlcw) Add'n Alter Repair Demo Sq. FL: # Stories: # ts: Telephone # of Contact Person: �f`� `'-I 3 Y — L/9 7T' Estimated Value of Project: NZ 00. °- APPLICANT: DO 52LeMJ=,TW UNE # Submittal Plan Sets Req'd Recd TRACKING PERMIT FEES Plan Check submitted Item Amount Structural Calcs.Reviewed, ready for corrections Plan Check Deposit W--' Truss Cafes. Called Contact n Plan Check Balanced a Title 24 Cafes. Plans picked up Construction 5-y� Z,q,'�-- Flood plain plan Plans resubmitted Mechanical Grading plan 2"' Review, ready for correctionsrusue aaAA Electrical 519 Subeontaetor List Called Contact Person Plumbing ^� Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading �. IN HOUSE:- 3" Review, ready for correctio o Developer Impact Fee �- Planning Approval Called Contact Person u A.I.P.P. Pub. Wks. Appr Date of permit issue OL to, School Fees Total Permit Fees g/"-9 -• ZAAX-p, . AcL NeDO -W R6 bpi• stA,.wW jW,#s*W ("V AJ) '