04-6958 (SFD);� 4 BUILDING & SAFETY DEPARTMENT P.O. Box 1504. (760),777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 . INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number X04-00006958 f Date 11/08/04 Property Address . . . . 77675 CALLE NOGALES APN: 773-325-001-26 -000000- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning COVE RESIDENTIAL Application valuation..". 99448 -Owner Contractor - ----------------------- ------------------------ POWER FINANCE CONTEMPORARY HOMES INCORP P.O. BOX 134 P.O. BOX 1141 LA QUINTA. CA 92247 LA QUINTA CA 92253 WCC: STATE FUND WC:. 16764082004 07/01/05 CSLB: 736920 03/31/05 CCC:' B . ------ Structure Information' SINGLE FAMILY DWELLING ----- Construction Type . . . . TYPE V -.NON RATED Occupancy Type . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . NON -AO FLOOD ZONE Other struct info . . . CODE EDITION 2001 CBC 4 BEDROOMS 3.00' FIRE SPRINKLERS NO GARAGE SQ FTG PATIO SQ FTG NUMBER OF UNITS ------_FIRST FLOOR SQ FTG\ ----------------- - - - - -- -------------------- Permit . . . ... . BUILDING PERMIT Additional des\\., Permit Fee 639.50 Plan Check Fee Issue Date Valuation . . 536.0 176,-f 00 �1 1 e' " 1, ',14. 00�� C e, 4'1568 x/99448 Qty Unit Charge Per Extension BASE FEE 414.50 50.00 41.5000 THOU BLDG 50,001-100,000 225.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional.desc.. Permit Fee 52.50 P1an.Check-Fee 13.13 Issue Date . . . . Valuation . . 0 Qty Unit Charge Per Extension . BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.0.0 2:00 6.5000 EA MECH VENT FAN 13.00 P.O. Box 1504 • ��IIG' Y7 � VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: �m'N—l„ 9 5$ I Date: //-ZS- o Applicant: C? 4, Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class License No. Date Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 74 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.& P.C. for this reason ,115�ate I l ' 2-`! ' t7 4 /_ Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Cartier Policy Number _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. )1.2-9. o WARNING: FAILURE TO SECURE WORKERS"COMPENSATION CCIL�AGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097. Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building ;te struction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. j ' 2 9 ' �- Sig/nature (Applicant or Agent): Application Number . . . 04-00006958 Page 2 Date 11/08/04 Qty Unit Charge Per Extension 1.00 6.5000 EA. MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 93.71 Plan Check Fee 23.43 Issue Date Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 1514.00 .0350 ELEC NEW RES - 1 OR.2 FAMILY 52.99 536.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 10.72 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit . . . . . PLUMBING Additional desc Permit Fee 135.00 Plan Check Fee 33.75 Issue Date Valuation . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 11.00 6.0000 EA PLB FIXTURE 66.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN.SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1'.00 15.000'0 EA PLB GAS METER 15.00 --------------------------------------------------- Permit ------------------------ GRADING PERMIT Additional desc Permit Fee . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1514 S.F. SFD PERMIT DOES NOT INCLUDE BLOCK WALL, POOL/SPA OR DRIVEWAY APPROACH -------------------------------------------------------------=-------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 . DIF CIVIC CENTER - RES 366.00 Page 3 Application Number . . . . 04-00006958 Date 11/08/04 ----------------------------------------'--------------=--------------------- Other Fees ENERGY REVIEW FEE. 41.57 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK'FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 9.94 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due Permit Fee Total 935.71 00 .00 935.71 Plan Check Total 485.99 250.00 .00 235.99 Other Fee Total 2456.51 .00 .00 2456.51 Grand Total 3878.21 250.00 .00 3628.21 Building -7-7 -7 Address uwner O'Ly 2 'Y Mailing Address I a —y L r•, J - Contractor C L- D,_-L-� Address 1/4 1 P. O TAVZ 4 4 a" P.O. BOX 1504 A LIC TIO4NLY 78-495 CALLE TAMPICO j 10 LA QUINTA, CALIFORNIA 92253 CC cc� V'�a,ry�,C� BUILDING: TYPE CONST.�OCC. GRP. I � 4 A.P. Number -7 -7/3 • � � O O pA Z�5 3 Tel.o� O Legal Description �kQ t 2� 7 D Project Description Tel. 'aa -53 56 8��0 State Lic. City & Classif. -7.3 t, Lic. # e2- 5 7 1 Arch., Engr., Designer F Y a_,k, DY G Address Tel. 4 5 4-0 0l3 c a C &-,44 oma, 2 0 6) 9 9 5 Cj x.20 Lic. # Zaicensed SED CONTRACTOR'S DECLARATION I Fieyet� If at under provisions pier -9 -(commencing with Section 00'1) of Dwi n 3 ofnesses Bions Code, and my license is in full force and OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sol compensation, will do the work, and the structure is not intended or offered for sale. 4, Business and Profes- sions Code: The Contractor's License Law does not n owner of property who builds or improves thereon and who doessuch work W hrough his own employees, provided that such improvements are not intended o ed for sale. If, however, the building or im- provement is sold within o etion, the owner -builder will have the burden of proving that he did no d or im e-for,the purpose of sale). ❑ I, as owner cclusively contracting with licensed contractors to construct the pro' o or ec c s and Professions Code: The C's License Law does not o a c r rty who builds or improves n, and who contracts for such s w' licensed pursuant to ntractor's License Law.) am nd C. P.C. for this reason �ORKER'S COMPENSATION DECLARATION I um that I have a certificate of consent to self -insure, or a certificate of Worker's Compens icon Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. ICompany ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Sq. Ft. / 5 Size No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Unit 1 77675 Calle Nogales Unit 2 Unit 3 Unit 4 Unit 5 Comments 1514 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does, not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,514 S.F. or $3,391.36 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Valley Independent Bank :Amanda Velez Check No. 319775 Name on the check Telephone 5648490 Funding Residential By Dr. Doris Wilson Superintendent . Fee collected /exempted by Sharon McGilvrey Payment Recd $3,391.36 Over/Under Signature 24) NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 9day approval period in which you may protest the fees o i other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authored to oohed them on the Distrk:tfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE Desert Sands Unified School District o 47950 Dune Palms Road <B BERMUDADUNESr Date 11/29/04- La Quinta, CA 92253 RANCHO MIRAGE d INDIAN WELLS No. 26656 (760) 771-8515 (Si PALM DESERT La INDIQ O �y �O yeti. Owner Power Finance APN # 773-325-001 Address Jurisdiction La Quinta City Zip Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 77675 Calle Nogales Unit 2 Unit 3 Unit 4 Unit 5 Comments 1514 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does, not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,514 S.F. or $3,391.36 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Valley Independent Bank :Amanda Velez Check No. 319775 Name on the check Telephone 5648490 Funding Residential By Dr. Doris Wilson Superintendent . Fee collected /exempted by Sharon McGilvrey Payment Recd $3,391.36 Over/Under Signature 24) NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 9day approval period in which you may protest the fees o i other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authored to oohed them on the Distrk:tfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy- Applicant/Receipt Copy - Accounting } 11/5/2004 8:48 RECORDING REQUESTED BY RhA American Tile Company AND WHEN RECORDED MAIL TO: 51370 Avenida Bermudas, #1 La Quinta, CA 92253 PACE 002/003 Fax Server GRANT DEED Above Thls Line for Recorder's Use only A.P.N.; 773-325-001-4 T.R.A. No.020-017 File No.: RPD -1588671 (sl) The Underdgned Grantor(s) Dedare(s): DOCUMENTARY TRANSFERTAX $110.00,, CITY TRANSFER TAX $&00; ( computed on the consideration or full value of luoperty conveyed, OR computed on the consideration or full value les: value of liens and/or encumbrances remaining at tme of sale, unincorporated area; () City of Lo Qjinta, hmd FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Frank H. Simmons and Rosemary Simmons 1. hereby GRANTS to Power Finance Associates, Inc., a California. Corporation the fallowing described property in the City of La Qulnta, County of Riverside, State of California: LOT 26, BLOCK 160 OF SANTA CARMELITA AT VALE LA QUINTA, UNIT NO. ie, IN THE COUNTY OF RnMRSIDE, STATE OF C/LLIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 18 PAGE 99 OF MAPS, RECORDS OF RMERSIDE COUNTY, CALIFORNM Dated:. 11/05/2004 Frank H. Simmons Rosemary Simmons Mail Tec Statements To: SAME AS ABOVE 1. r Z 'd M g 'ON NlddNg Wa1111M Wd6q:6 tiOOZ 'q '^ON 11/5/2004 8:48 PAGE 003/003 Fax'Server A.P.N.: 773.325-001-4 Grant Deed - continued Fife NO.:RPD-1586671 (sl) Date: 11/05/2004 STATE OF } ) ss. COUNTY OF } On before me, personally appeared personally known to me (or proved to me of the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged tome that he/she/they executed the same in his/her/their authorized capacity(ies) and that his/her/their slgnature(s) on the instrument the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and offidal seal. This area for offlaaj notoria/seal Signature My Commission Expires:. Notary Name: Notary Phone: Notary Registration Number: _ County- of Principal Place of Business: Page 2 of 2 £ A tiM'ON N1JJH Wb'I111M WN00:6 ti00Z '0 '^ON RC DISTRICT - PLANNING REVIEW FORM This form is to be used by CDD.staff for review of single family dwellings jn the RC '(Cove' Residential) District per Section 9.50.090 of the Zoning Code. Its purpose is to determine: 1) that the proposed housing design does not duplicate the same architeci;ural style of any house within 200 feet of the applicant, .and/or 2) if there is a need for the applicant to file .for Master Design Guidelines. If the applicant does need to file a Master Design Guideline, please transmit this information to the Building and Safety Department as part of your correction list. Please attach additional explanations,as necessary. i' 10 1. ��- 1•._ J APN - 3a s- OD CASE NO-.:' iD 37 LEGAL: LOT 6 BLOCK UNIT S.C.(OV.L.Q. CHECK AND APPROVED.BY: DATE: Inform the assigned Building plan checker upon your assignment to this case. The CDD Executive Secretary maintains a log book to track applications. and assign case numbers. REQUIRED ITEM Y N COMMENT/CORRECTION Verify legal and APN information Consistent with. MDG on file. (as applicable) MDG filing required (5 filings since 9/3/98) Architectural variety within 200 feet of the surrounding area: Architectural design. features roved b Date Reso # City Council ommunity Dev. Dept. ----- . C E s se No. thibit ---- With Conditions Other Requirements: OCT -05-2005-06:11 AM CER AND DIAGNOSTIC P.02 rESTIN `' CF -4R Dat Builder Nan ie Plan Numbr::r Semple Grc: up Number Ifying Signature D e Sample Hoi. se Number Firm: ��. /i%s criu�- S // / HERS Provider: /y Street Address; 7-go sewdI?'oI (../►'C�E, Clty/State/Zip: Lu I'��!' C�? 9z.2_r� Copies to: Builder, HERS Provider ITERCOMPLIANCE STATEMENT The house was: ested ❑ Approved .as part of sample testing, but was I tot tested As the HERS raterrovldin diagnostic testingand field verification, I certify that the Douses identified on this form corn with the diagnostics sated compliance requirements as checked on this form. corn system Is fully ducted (i.e., does not use building cavities as plenur is or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape Is Installed, mastic and drawbends are used In combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.: MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANd;';E CREDIT Duct Diagnostic Leakage Testing Results (Maximum 0% Duct Leakage) tileasured Duct Pressurization Test Results (CFM ® 25 Pa) values Test Leakage Flow In CFM If fan flow is calculated as 400cfm/ton x number of tone enter calculated value here_ If fan flow Is measured enter measured value here Leakage Percentage (1 00 x Test Leakage/Fan Flow) Check Box for Pass or Fall (Pas9=6% or less') ❑ ass Fall THERMOSTATIC EXPANSION VALVE TXV or Commission approved a uival,:nt Yes . ❑ No Thermostatic Expansion Valve '(or Commission approved equivalent) Is Installed and Access is provided for Inspection—❑ Yes is a pass Pass Fall MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes ❑ No ACCA Manual D Design requlrements have been met (rater has verified that actual installation matches value:; In CF -IR and design on plan. 1 2. ❑ Yes No TXV Is Installed or Fan flow has been verified. If no TX,', i verlfled fan flow matches design from CF -1 R. Measured Fan Flow = :. ❑ ❑ . Yes for both 1 and 2 is a P;,tss pass Fail 5 _ r r - ,- ..Certificate. of Occupancy - . _ -G�oF9 Buildin & Safe -Department 5 g _Y This."Certificate pis issued pursuant to the requirements of Section 109, -'of the California Building ,Code, certifying -that, at the 'time of -issuance, this structure was, in compliance 'with the provisions of the Building • Code and the various ordinances of- the City regulating building ' construction and/or use. • BUILDING ADDRESS:. 77-675 CALLE'NOGALES , Use classification:'.,SINGLE FAMILY DWELLLING -. Building Permit No.: 04-6958 Occupancy Group: R3 Type of Construction: V -N Land Use Zone: RC Owner of Building: POWER FINANCE' x. - Address: P,O, BOX 134 l • City, ST, ZIP: LA QUINTA, CA 92253 By: KIRK KIRKLAND Date: OCTOBER 7,.2005 Building Official POST IN A CONSPICUOUS PLACE _ r r TITLE 24 REPORT M-AzA t L,A N Title 24 „Report for: Thomas Buffin Power Brokers Mazatlan-AIl' Orientations La Quinta; CA 92253 Project Designer: Frank A. Moreno 45-400 Big Canyon Street Indio, CA 92201 760-200-9956 Report Prepared By: Frank A. Moreno Power Brokers 51370 Avenida Bermudas Suite 1 n 01 iintm ( _A 077ri Job Number: o«c 00.101 Date: 10/11/2004 The EnergyPro computer program has been used to perform"the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft; LLC (415) 897'1-6400. EnergyPro 3.1 By EnergySoft Job Number: 00101 User Number: 6115 y Certificate of Compliance: Residential (Partl of 2) CF -1 R Thomas Buffin Power Brokers 10/11/2004 Project Title Date Mazatlan -All Orientations La Quinta Project Address Building Permit # - Power Brokers (760) 564-8470 Documentation Author . Telephone Plan Check / Date Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1, 514 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,514.f? Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus'Addition Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Number of Stories: . 1 Floor Construction Type: ® Slab Floor ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATInN SHQC Shadin Yes / No ollaunig uevices Type Orientation Area Fenestration Exterior Overhang Side Fins SF) U -Factor SHQC Shadin Yes / No Yes / No Front 53.4 0.85 0.70 Woven Sunscreen 191 ❑ ❑ 0 Front 29.0 0.72 0.73 Bug Screen ❑X ❑ ❑ Q Front 55.5 0.87 0.70 Bug Screen X❑ El ElFront 1.0 0.72 0.73 Woven Sunscreen ❑x El 0 Left 20.0 0.87 0.70 Woven Sunscreen El El 0 Left 8.0 0.72 0.73 Woven Sunscreen 191 [] ❑ 0 Rear 58.0 0.87 0.70 Woven Sunscreen❑ 91 ❑ El Q Rear 12.0 0.72 0.73 Woven Sunscreen ❑ El X❑ Right + 35.0 0.87 0.70 Woven Sunscreen 191 ❑ ❑ 0 Right 33.4 0.85 0.70 Woven Sunscreen X❑ ❑ ❑ 0 Right 10.0 0.72 0.73 Woven Sunscreen Q ❑ ❑ R ❑❑ El Run Initi io Time: 10/11/04 22:19:16 u Code: 108 68356 Ener Pro 3.1 By Ener Soft User Number: 6115 Job Number: Pa e:3 of 12 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Thomas Buffin Power Brokers 10/11/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Heating Equipment Minimum Distribution Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc) R -Value Type Comments Central FumarP 92% AFUE Ducts in Attic 4.2 _ Setback Res HVAC Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap.`cooling) (SEER) (attic, etc.) Duct R -Value Thermostat Location / Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setha .k Res HVAC WATER HEATING SYSTEMS . Water Heater Water Heater 'Distribution # in System Name Type - Type Rated 1 Input Tank Energy Facts 1 External Cap. or Recovery Standby Tank Insul. Syst. Standard ac � cc small nas Standard �_ Btu/hr 40-000 ' (gal) Efficiency Loss (%) . R -Value 5Q 053 _ n!a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btufhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heater; (rated input of than 75,000 Btufhr), greater list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Frank A. Moreno Address: 45-400 Big Canyon Street Indio, CA 92201 Telephone: 760-200-9956 Lic. #: NZ9A� �. • ro -rl� 04 - (signature) (date) Enforcement Agency Name: ' Title/Firm: Address: Telephone: Name: Frank A. Moreno Title/Firm: Power Brokers Address: 51370 Avenida Bermudas Suite 1 La Quinta, CA 92253 Telephone: (760) 564-6470 (signature) (date) m 3.1 By EnergySoft User Number: 6115 Job Number: 00101 Pane:4 of 12 Certificate of Compliance: Residential (Addendum) CF -I R Thomas Buffin Power Brokers 10/11/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specked in this checklist: These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adeauacv of tha cnaci2i HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a fen„ eF.aa The HVAC System 'Res HVAC' includes Refrigerant Charge and Airflow Credit,(or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. • a rIC1Y The HVAC System "Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. M • 4n/44/nA -"- User Number: 6115 Job Number 00101 of 12 Mandatory Measures Checklist: ' Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a 4150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. ❑X §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does • not apply to exterior mass walls). *6150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑ §150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 punch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(8): Vapor barriers mandatory in Climate Zones -14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Meas F§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. F§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. o3.1 By EnergySoft User Number: 6115 Job Number: 00101 Page:6 of 12 Mandatory Measures Checklist: Residential (Page 2 of 2) ' MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eithereutomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fiker and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btuthr) ❑§118 (f): Cool Roof material meet specified criteria Lighting Measures F] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumensiwatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 6115 Job Number: 00101 Page:7 of 12 Computer Method Summary (Part 1 of 'Al C 20 Thomas Buffin Power Brokers 10/11/2004 Project Title Date Mazatlan -All Orientations La Quinta Project Address Building Permit # Power Brokers (760) 564-8470 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Facing North Margin Facing East Margin - -0 Wall 347 n n59 n An Wall 393 _ n n5Q An An Wall 4170 059 180 90 Facing South Margin ❑ ❑ ❑ ❑ ❑ ❑ 7 Facing West Margin 3.49 -1.17 34.50 3.52 3.30 -0.98 3.13 -0.82 3.20 -0.88 Space Heating 2.31 Space Cooling 38.03 Domestic Hot Water 15.66 15.51 0.16 H❑ 35.86 2.17 15.51 0.16 34.56 3.47 15.51 0.16 ❑o 35.93 2.10 15.51 0.16 53.50 2.51 54.66 1.34 53.20 2.81 54.63 1.37 w Totals 56.00 1 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 1,514 ft 2 Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 20.8% Number of Dwelling Units: 1.00 Total Conditioned Volume: 15,140 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,514 ft BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type H t. Area Res HVAC 1 1� 5 '140 1 n _- C onditionedath _2 n//a S aCk _ OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Am. Tilt v / N Rnnf 1*��4 A 92 . -. ••wcanon / %,ornments - -0 Wall 347 n n59 n An Wall 393 _ n n5Q An An Wall 4170 059 180 90 y� IN ❑ ❑ ❑❑ ❑❑ ❑❑ ❑E ❑❑ ❑❑ ❑❑ o❑❑ ❑H ❑ ❑ ❑ ❑ ❑ ❑ 7 R-38 Rnnf R 38 1x14 1 ( ----_� 1ct Floor 7nnp R-13 Wall w/1" FPR pct Floor 7nna R-13 Wall w/1" FPS _1ct Floor 7nnp R-13 Wall w/1" FPR 1 Rt Flonr 7nnp R-13 Wall w/1" FPR est Flom 7nnp Wall 2790 059059 7p AQ H❑ ❑o ❑ ❑❑ an Time: 9 8115 3.1 By EnergySoft User Numh- ""'"' Page:8 of 12 VV1ilpmer IYIetnou summary (Part 2 of 3) C 2R Thomas Buffin Power Brokers Project Title 10/11/2004 Date FENESTRATION SURFACES # Type U- Act. Glazing Type Location/ Area Factor SHGC Azm. Tilt Comments J_ Window Front (North) X0-0 0.850 070 2 Window Front (North) 6.0 0.720 0.73 _0 0 . 90 Double Metal I ar Default 90 Double Metal Clear Default 1 st Floor Zone 1st Floor Zone 3 4 Window Front (North) Window Front (North) 25.0 10.0 0.870 0.70 0 90 Double Metal Clear Default 1st Floor Zone 5 Window Front (North) 20.0 0.720 0.870 0.73 0 90 Double Metal Clear Default 1st Floor Zone 6 Window Front 0.70 0 90 Double Metal Clear Default 1 st Floor Zone (North) Window Front 6.0 0.720 0.73 0 90 Qouble Metal Clear Default - 1st Floor Zone -7- 8 . (North) Window Front (North) 10.5 7.0 0.870 0.720 0.70 0.73 _�_ 0 Qouble Metal Clear Default 1st Floor Zone 3 Window Front (North) 33.4 0.8500.70 0 0 90 Double Metal Clear Default 1 st Floor Zone 11 11 Window Front (North) Window Left ( ash 1.0 20.0 0.720 0.870 0.73 0.70 90 Double Metal r Default 0 90 Double Metal CleCleaar Defa ft 90 90 Dstuble Metal Clear Default 1st Floor Zone 1st Floor Zone 1st Floor Zone 12 1U Window Left (East) Window Rear (South) 8.0 25.0 0.720 0.870 0.73 0.70 90 180 90 Double Metal Clear Default 1st Floor Zone 14 15 Window Rear (South) Window Rear (South) 4.0 0.870 0.70 180 90 Double Metal CI ar D fat 90 Double Metal Clear Default 1 st Floor Zone 1st Floor Zone Window Rear (So 25.0 4.0 0.870 0.70 180 90 Double Metal Clear Default 1st Floor Zone 17 Window Rear (South) 12.0 0.870 0.720 0.70 0.73 180 90 Double Metal Clear Default 1st Floor Zone 18 Window Right (West) 25.0 0.870 0.70 180 270 90 Double Metal Clear Default 1 st Floor Zone 12 Window Riglli_(Wectl 90 Double Metal Clear Default 1st Floor Zone 20 Window Right (West) 10.0 33.4 0.870 0.850 0.70 0.70 270 270 90 Double Metal Clear Default 90 Double Metal Clear Default 1st Floor Zone 1st Floor Zone 21 Window Right (West) 10.0 0.720 0.73 270 90 Double Metal Clear Default 1st Floor Zone INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. Hgt LEA RExt Dist Right Fin 1 Woven Sunscreen 0.30 6.6 3.0 0.0 0.0 Len 0.0 0.0 Hgt Dist Len Hgt 2 Bug Screen 0.76 2.0 3.0 10.0 0.1 10.0 10.0 3 Bug Screen 0.76 5.0 5.0 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 2.0 5.0 6.0 0.1 6.0 6.0 5 6 Bug Screen 0.76 6.6 3.0 6.0 0.1 6.0 6.0 7 Bug Screen Bug Screen 0.76 2.0 3.0 6.0 0 1 6.0 6.0 8 cre Bug Sen0.76 0.76 3.0 2.0 3.5 3.5 6.0 6.0 0.1 0.1 6.0 6.0 6.0 6.0 9 Woven Sunscreen 0.30 6.6 5.0 0.0 0.0 0.0 0.0 10 Woven Sunscreen 0.30 2.0 5.0 0.0 0.0 0.0 0.0 11 Woven Sunscreen 0.30 5.0 4.0 0.0 0.0 0.0 0.0 12 Woven Sunscreen 0.30 2.0 4.0 0.0 0.0 0.0 0.0 13 Woven Sunscreen 0.30 5.0 5.0 0.0 0.0 0.0 0.0 14 Woven Sunscreen 0.30 1.0 4.0 0.0 0.0 0.0 0.0 15 Woven Sunscreen 0.30 5.0 5.0 0.0 0.0 0.0 0.0 16 Woven Sunscreen 0.30 1.0 4.0 0.0 0.0 0.0 0.0 17 Woven Sunscreen 0.30 2.0 6.0 0.0 0.0 0.0 0.0 18 Woven Sunscreen 0.30 5.0 5.0 0.0 0.0 0.0 0.0 19 Woven Sunscreen 0.30 2.0 5.0 0.0 0.0 0.0 0.0 20 Woven Sunscreen -Sunscreen-0.30 0.30 6.6 5.0 0.0 0.0 0.0 0.0 21 Woven 2.0 5.0 0.0 0.0 0.0 0.0 3.1 By EnergySoft User Number: 6115 Job Number: 00101 Page:9 of 12 Computer Method Summary (Part 3 of 3) C 2R Thomas Buffin Power Brokers 10/11/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R Val Comments PERIMETER LOSSES F2 Insulation ape Length Factor R -Val. Depth Location / Comments Slab Perimeter 90 0_76 0 161 Floor Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat pump, etc.) Efficiency (AFUE/HSPF)(ducts/attic and Location etc) Duct Thermostat R Value Location I Type Comments Central Furnac g2 /a o AFUE Ducts in Attic 4.2 Setback Res HVAC Hydronic Piping System Name Pipe Pipe Length Diameter Insul. Thick. Cooling Equipment Minimum Duct Type (air conditioner, heat pump, evap. cooling) Efficiency (SEER) Location Duct Thermostat Location / (attic etc) R Value Type Comments Sold Air Condition r 12.0 SEER Ducts in Attic 4.2 Setback Res HVAC WATER HEATING SYSTEMS Water Heater System Name Water Heater Type Distribution Ratedl Tank Cap. Energy Fact! 1 Tank Insul. or Recovery Standby R -Value Type Syst (Btu/hr).Input (gal) Efficiency Loss (/o) Ext Standard Gas 50 gal or Less Small Gas Standard �_ 40.000 50 0.53 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. M -M A waw P Computer Method Summary (Addendum)C-2R Thomas Buffin Power Brokers 10/11/2004 Project Title Date Special Features and, Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement based on the adeauagency acv of detethP aines the degacy of the justification, and may reject a building or design that otherwise complies HERS. Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -SR- The HVAC System 'Res HVAC' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. r you rICw The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. • A r t 1 F 3.1 T User Number: 6115 00101 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME , Thomas Buffin Power Brokers DATE SYSTEM NAME 10/11/2004 Res HVAC FLOOR AREA 1.514 Number of Heatino Sv Total Output (Btut Output (Btuh/sqft) Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgftlron) CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (°�) Outside Air (cfm/sqft) Note: values above given at ARI conditions 26.0 OF 69.2 OF Outside Air 0 cfm 69.2 OF 15.0 / 73.5 OF Outside Air 0 cfm 78.9/62.3 °F Supply Fan 1595 cfm s2,000Total Room Loads 92,000 Return Vented Lighting 60.81 Return Air Ducts Return Fan Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM 47,000Ventilation 47,000 3.9 31.0 386.6 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 111=�' 722 26,895 1,345 0 0 0 0 0 0 0 0 0 1,553 1,345 34,173 -449 1,595 ----- 1,595 BDP CO.563AN048-A 36,695 2,708 1.05 407.2 A Total Adjusted System Output 36 695 2,708(Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 69.2 OF 105.0 of Heating Coil h Retum Air Ducts 4 78.9 / 62.3 OF 78.9 / 62.3 OF 55.0 / 53.5 OF Supply Fan Cooling Coil 1595 cfm 92,000 92,000 Jan 12 am �Suppl cts 104.2 OF ROOMS 70.0 OF Supply Air Ducts 55.9 / 53.9 of 40.5% R.H. ROOMS 78.0 / 62.0 OF Retum Air Ducts 3.1 By EnergySoft User Number 6115 Job Number: 00101 12 of 12