15441 (SATT)-T -tit 4
�
P.O. BOX 1.504 N o . 154-41.
Building; ti - 78.14„95 CALLE TAMPICO
Address ,��..19p;'adise :has Fir. T' LA QUINTA, CALIFORNIA 92253
Owner
MailiB.G. Williams Development �'OM BUILDING: TYPE CONST. VN OCC: GRP. R1
ng
Address 42 -600 Cook St. Suite 120
A.P. Number
City Zip Tel. Lotl Tract 28019
Pala Desert, 92211 (619)341-6880 Legal Description
Contractor A f
Same Project Description `��� � `��t Plan
Address senior Houzinq at The Seasons
City Zip Tel.:
State Lic. City
& Classif. B 493919 Lic. # 1231
Arch., Engr.,
Designer Stof fgren Fuller &, Associates
Address Tel.
68-487 E. Palm Canyon (619)328-180
CityState
Cathedral CityTzipCA 92234 Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
e000)1 f Division 3 of the Business and PrbfessionCode,and my license is in full force and
r r' rte.. t.' . .X0 :t _oc L __� ra.j (9^../ <. - t;
OWNER -BUILDER DECLARATION
I hereby affirm that 1 am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, after, Improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Lew, Chapter 9 (commencing with Section • 7000) of
Division 3 of the Business and -Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by Any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an, owner or property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such Improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
O 1, as owner -of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
-does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractors) Licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
Grp Copy Is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California-
Date-Owner
aliforniaDateOwner
NOTICE TO APPLICANT, If, after. making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND
SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE
HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION,
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND
ATTORNEY'S FEES.
This is a building permit when properly filled out, signed and validated, and is.subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state.laws relating to building
construction, and hereby authorize representatives of this city to enter the above-:
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
Sq. Ft. No. No. Dw.
Size 639 Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation $31,424.00
PERMIT
AMOUNT
Plan Chk. Dep. .
Plan Chk. Bal.
271.68
Const.
297.50
Mech.
49.00
Electrical
78 82
Plumbing
108.00
S.M.I.
3. 1
Grading
20.00-
0.00Driveway
DrivewayEnc.
60
Infrastructure
707.04
TOTAL
1.535.18.
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from er L
Rear Setback frog r Pro 11bfi
Side Street SetItb from Ce ine
Side Setback m Prepe v Line
n �N
FINAL DATE
Issued by:
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
IST FL. SO. FT. ® $
UNITS
SLAB GRADE,/
ROUGH PLUMB:
BONDING
YARD SPKLR SYSTEM
2ND FL. SO. FT.
FORMS/Q fff�
/
SEWE R 1f�
ROUGH WIRING .
MOBILEHOME SVC.
BAR SINK
POR SO FT ®
GAS (ROUGH) / 6
J
METER LOOP
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
GAS (FINAL)
TEMP. POLE
DRAINAGE PIPING
CAR P. SO. FT.
GROUT
WATER HEATER
WALL SO. FT.
FINAL INSP.
DRINKING FOUNTAIN.
SO. FT. ®
WATER SYSTEM
URINAL
ESTIMATED CONSTRUCTION VALUATION $
_$
WATER PIPING
NOTE: Not to be used as property tax valuation
FRAMING //`(/ ��
FLOOR DRAIN
MECHANICAL FEES
,�J�
U ,/I�j•�% / `/ Ti• 7
WATER SOFTENER
VENT SYSTEM FAN EVAP.000L HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRYTRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
INSULATION/SOUND Z �G
SO.FT.GAR ® 3/ac
HOUSE SEWER
FINISH GRADING
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUM /�
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE,/
ROUGH PLUMB:
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS/Q fff�
/
SEWE R 1f�
ROUGH WIRING .
DUCT WORK
ROCK STORAGE
FOUND. REINF. /6 / /J
7,
GAS (ROUGH) / 6
J
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL �G
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR.
FINAL INSP.1� &
FRAMING //`(/ ��
FINAL INSP.
ROOFING •�//
,�J�
U ,/I�j•�% / `/ Ti• 7
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND Z �G
FINISH GRADING
p
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES11NITIALS
GARDEN WALL FINAL
Fiber Glass Blankets when
installed according to the
manufacturer's recom-
mendations will provide the full
rated thermal resistance value.
Blanket Insulation
R
Minimum
Value _Thickness
2x6
tR-values indicated obtained 2x4
To obtain an
Installed
insulation
insulation
resistance
should
(R) of: _
..
not be less than:
_ ---
R-38 _
h"
13"Thick' _
R-30 -
9'A" Thick'
R-26
8J/4"Thick
R_-22
71/2" Thick
R-19
61/2" Thick'
R-13
3h/s" Thick -
hick"R-11
R -1 1
31/2" Thick
'Thickness varies, check bag
label for producing locations
thickness.
"R-12 7 in a 31/2" cavity
To meet the thermal resistance value (R); the manufacturer has specified the number of bags per..,
1000 sq. ft. of net area that must be installed to'meet both the minimum design thickness and
minimum wt./sq. ft. requirements. Installing the correct number of bags/ 1000 sq. ft. is necessary to
meet the corresponding labeled resistance (R) value. (Based on 40 Ib. nominal net weight bag).
Rich-Rr" Fiber Glass Blowing,
Wool Attic Insulation --40 Ib. Bag.
14.1 aa'
2x6
tR-values indicated obtained 2x4
,<<;
14.3
14.6
when properly installed with
:::
pneumatic equipment. R-19 2x8
R
Bags per
Maximum
Minimum
Minimum
Installed
Value_t
1000s ft.
Net Coverage
Wt./sq. fti.
Thicknes_ s
Ttikkr>•ss ?:+
To obtain
The number of
Contents
The weight
Installed
Average
an insula-
bags per 1000
of this bag
per sq. ft. of
insulation
installed
La
tion resis-
sq. ft. of net
should not
installed insul-
should
thidkttest3::.:
formance with the above recommendations to provide an R -value
tante
area should not
cover
ation should not
not be
will
square feet of area at
(R) of:
be less than:
more than:
be less than:
less than:
typically be
. :'.;:
�,�.
R-44
_ 291/2
34 sq. ft.
1.188 lbs.
15" Thick
181/2
_
R-38
251/2
39 sq. ft.
1.029 lbs.
13" Thick
141/4"
R-30
201/2
49 sq. ft.
0:811 lbs.
101/4" Thick
111/4
R-22
15
67 sq. ft.
0.594 lbs.
71/2" Thick
81/4"
R-19
13
78 sq. ft.
0.514 lbs.
61/2" Thick
71/4
R-11
71/2
135 sq. it.
0:297 lbs.
32/4" Thick
41/4"
r '
Rich -Rt" Fiber Glass Blowing
Wool Sidewall Insulation -404b. Bag.
T
�=
R_-16
161/2'
60 sq. -ft'. '. '.
_ 0.667 lbs.
4" Thick
4"
R-14
15
66 sq: ft.
'0.604 lbs.
3%" Thick
34e"
R-14
141/2
68 sq. ft.
0.583 lbs.
31/2" Thick
31/2"
Average installed thickness is provided as a guide to installers. Actual thickness will vary
Seasons Apartments depending on conditions at the time of installation. To obtain a specific R -value, Insulati"
Building 2 should not be applied over a larger area than specified on the coverage chart.
La Quints, CA 92253 Net wt./bag, minimum 37`lbs. This product conforms. to the performance requirements of
Federal Specification HH -1-10308: Type I, Class B, and DOE RCS Standards. Also ffteets
�Q PO ('o Al !;C &15f Insulation Quality Standards of the State of California.
Framing Correction for 40 Ib. Framing 16" on center. Framing 24" on cent-> ,
Bag. Rich -R Blowing Wool R Joists Sags.per 1000 sq. ft. Bags per 1000 sq. fL
Valuest Dimensions (gross) (gross)
When installing in attics of new R.44 2x8 28.2 28.6
homes or existing homes where 2x6 28.5 28.8
no insulation is present, it is
acceptable to adjust the --- 2x4 28.9 29.1
coverage figures to compensate R-38 2x8 24.2 24.6 +'� • �'
for the presence of the framing 2x6 24.5 24.8 ` z
members as indicated in the
2x4 24.9 25.1
following table. R-30 2x8 19.1 19.6 "=
2x6 19.5 19.8
2x4 19.8 20.1 a
A
R-22 2x8
13.6.
14.1 aa'
2x6
tR-values indicated obtained 2x4
14.0
14.3
14.3
14.6
when properly installed with
:::
pneumatic equipment. R-19 2x8
11.8
12.2
i.;„;:
2x6
12.0
12.3
The higher the R -value, the 2x4
12.3
12.6
greater the insulating power. R-11 2x8
6.8•
7.1
Ask your seller for the fact sheet 2x6
6.8
7.1'�
on R -values. 2x4
6.8
7.1
:r ;
Batts and rolls have been installed in conformance with the above
Blowing wool has been installed
in the ceiling or sidewall in cors-
: ': •:.
recommendations to provide a thermal resistance value of
formance with the above recommendations to provide an R -value
R-3 _ at -._ __ inches in sq. ft. of ceiling, R- 13 at
of R- ' using
bags of this insulation to cover
_ inches in 222- sq, ft. of exterior wails, and. R- at
square feet of area at
inches in ..___- sq. ft. of floors or crawl space perimeter.
minimum thickness of
inches.
Dante' Signature D ^w
Date signature
HIG-616 71136
.:.1K
Insulation Contractor ROM MULATION
74-741 Joni Drive
PALM DESERT, CALIFORNU 92254
(4t•19) 346-2339 pirin
Residence .Addmss: Seasons Apartments Buildiriq 29 .
Sb C 19so l C A f 22;S 3
CERTIFICATION This is to certify thatattic insulation has 1-een installed in conformance with
the coicra ;lac recommendations on the oppoike <i&of this :ard using 132 bags m
cover sq. i< m clears an tivalue of 33
Contr=oes authorrsi signature
Dao. 31 to We
:Intalled hr Builder
ROVER INSULATION
i&241 JON1 DRIVE
' PALM DESERT, CA 92260
(619) 346-2339
'THE difS TIOX'SPECIALIST)
. R PRO PLUS
«Corde>v
STABILIZED INSULATION
MANUFACTURED BY
GREENSTONE INDUSTRIES
Atlanta, Georgia E1666d, Virginia • Ft Wayne, Indiana
Norfollt, Nebras4a .• 'Phoenix, Arizona Fbrtland, Oregon
ATOMIZED -PNEUMATIC APPLICATION COVERAGE CHART
3:5 39.6 ..
25.3
. .. Net Coverage
R-20 (2 x 6)
R -Value of
39.7
No A*Ztmertt for Trusses
�coli"
Mean
AAulirtwse
Maximum
Minis um
Teffvemperaturo
Thicluum
Trusses on I$"
Net
weight Per
Centers
Coverage
square Foot
To Obtain
. Instated
Square
Minimum
'The Weight Per
Suare
Bags
an Insulation
Irisutabon
Feet
Bags
Sq. Ft. of
Feel.
Required
Resistance
ShDtk-N r
Per
Required
Installed
Per
Per 1,000
(R) of
Be Less Thw4
Bag
Per 1.600
mutation Should
Bag
Square Feet
(indW
Square Feet
Not Be Less
Than: (Itis)
R-50
13.5
20.5
48.8
1.464
21.3
46.9
R-42..
11.4
•24:4
41,:0 ..
1:230' -
25.6
39.1
.;
R-40
10:8
25.6 ' - .
39:0 _
-1.1172
264
37.2
R-38
10.3
27.0
37.1
1.113
28:4
35.2
R-32
8.6
32.0
34.1 '
.937.'
34:1
29.4
R-30
8.1
34.2
29.3
878
36.5
27.4
R-24
.6 .5
42.7
23.4
.703
46.4
21.6
R-22
:5.9
46.6
21.5
.644
51.0
19:5
R-19
5.1
53.9
18.5
.556
59.6
16.8
R-13
.3.5
78.8
12.7
.381
87.0
11.5
)3.2
10.7 '
r.322
102.8
9.7
Sidewall's (pressure Fi1'led-'d'ens4V,2.6 PPCF) '
1.3 (2 x4)
3:5 39.6 ..
25.3
.758.
R-20 (2 x 6)
1 5.5 25.2
39.7
1.192
Note: This coverage chart compensates for settling and is for estimating purposes only.
Stated R -Value is provided by installing the required number of bags per 1000'sq. ft. at a
minimum installed thickness. Installation of the required number of bags may yield more
than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will
be influenced by job conditions and application techniques, and may vary as -much as 10%
without significantly affecting the stated R -Value. Failure of the installer to provide at least
the required numberof bags per 1000 sq. ft. and at feast the minimum thickness may resik
in a lower installed R -Value after settling. Compaction may occur during installations above R-
30 reeuirintl .more than the stated number of bags to obtain the minimum installed thickness.
tom:
AW •_
��lrtTtf 0thi.
f 0 Ita
11ilbin*l allb ' v " S6. afvt� Bilklioll
This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building
Code certifying that at -the time of issuance thisstructure was in compliance with the various
ordinances of the City regulating building construction or use. - For the following;
BUILDING ADDRESS 50-980 Paradise East Dr. F
Use Classification SFA'— Apartment Blog. Permit. No. 15441
Group R-1 Type Construction VN Fire Zone Use Zone R-1
Owner of Building
E.G. Williams Development Address 42-600 Cook St. Suite .120
.City Palm Desert, CA., 92211 By: Daniel P. Crawford Jr.
Date; Ari riL 18, 1996--
7
I
Buildijng Official POST IN A CONWIPICUOUS PLACE
1 0 P
E 11111111 ]Mill Ml HIM