15457 (SATT)t4tv
Y7Cu
TiNT o 14a 011hita
Itit1iIt-� "d 111dfet i1ti'!�iItIt
This Certificate issued pursuant to the requirements. of Section 306 of the Uniform .building
Code certifying that at the time of issuance this structure was in compliance with the various
.ordinances of the City regulating building construction or use. For the following:
BUILDING ADDRESS 50-890 Paradise East Dr..B
Use Classification SFA — Apartment Bldg. Permit No. 15457
Group R-1 Type Construction VN Fre Zone Use Zone R-1
Owner. of Building E.G. Williams DevelopmentAddresd 42-600 Cook St. Suite 120
Palm I�esert�_A., 92211 Daniel P. Crawford Jr.
,an
fII
X
I,
Date; March.29, 1996
�i
` BuildingOfficial
POST IN A CONSPICUOUS L ACt
tin
--- �
•..,._ ..._ _. _.._._. ._ ..
�,�..�r�1'�..q�►k"`-�ie�Mha�:3�►�we.:�a'.`iirw,�-=i�ca.i FW_-
Building.
Address
50 OFF
e
.44
P.O. BOX 1504
�y 78-495 CALLE TAMPICO
lF Yrs B LA QUINTA, CALIFORNIA 92253.
B,u.yiii.i,.:1.amsyeyeiopment corp
Mailing
Address 42-600 Cook St. Suite 120
City Zip Tel.
Palm Desert, C 92211 (619).341-6880
Contractor
Same
Address
ty
State Lic. City
& Classif. B 493919 Lic. # 1231
Arch., Engr.,
Designer St®if ;:en Fuller & Asso.ciates
Address I Tel.
City Zip I State
Cathedral City, CA 922341Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter -9 (commencing with Section
7000) of Division 3 of the Business and, Professions, and my license is in full force and
effect. ` 'I f . / ' p
SIGNATURE/ �S !' ' r DATE
�! OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires' a
permit to construct, after, Improve, demolkh, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business'and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code:.The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not Intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an. owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) jkensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec: 3800. Labor Code.)
Policy No. Company
-0 Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed it the permit Is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California
Date Owner
NOTICE TO APPLICANT: H, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions or the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND
SHALL SUBJECT AN EMPLOYER TO CRIMINAL' PENALTIES AND CIVIL FINES UP TO ONE
HUNDRED. THOUSAND DOLLARS ($100,000),:IN ADDITION TO THE COST OF COMPENSATION,
DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, 'AND
ATTORNEY'S FEES.
This is a building permit when properly filled out, signed and validated, and is subject to -
expiration If work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws, relating to building
construction, and hereby authorize representatives of this city to .enter the'. above-.
mentioned property for inspection purposes. -
Signature of applicant Date
Mailing Address
City„ State, Zip
N.O. 15457
BUILDING: TYPE CONST:vil
OCC: GRP. �1
A.P. Number
Legal Description Lot ITract 28019
Project Description SPA —.Apartment plata 2
Senior Housing at The Seasons
Sq. Ft. No. No. Dw.
Size 822 Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation $4.2,415.00
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
323.66
Const.
369.00.
Mech.
49.-00.'
Electrical
82.27'
Plumbing
108.00
S.M.I.
- 4-024..
Grading
2.0.00
Driveway Enc.
. 00,
Infrastructure
954.34
TOTAL
REMARKS
ZONE. BY:
Minimum Setback Distances:
Front Setback from Center ince,
Rear Setback from Rear P
Side.Street Setback frog ter LiF�e
Side Setback from Pio I Liner`
FINAL DATE INSPECTOK45'
Issued by:
Validated by:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBINU FEES
1ST FL. SO. FT. ® $
UNITS
E.
ROUGH PLUMB.
BONDING
YARD SPKLR SYSTEM
2ND FL. SQ. FT.
FORMS�Q
EWE R P
ROUGH WIRING
MOBILEHOME SVC.
BAR SINK
POR. SO. FT. ®
GAS (ROUGH) Q�
77
METER LOOP
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
GAS (FINAL)
TEMP. POLE
DRAINAGE PIPING
CAR P. SO. FT.
GROUT
WATER HEATER
WALL SQ. FT. ®
FINAL INSP.
DRINKING FOUNTAIN.
SO. FT. ®
WATER SYSTEM
URINAL
ESTIMATED CONSTRUCTION VALUATION $
=$
WATER PIPING
NOTE: Not to be used as property tax valuation
FRAMING
FLOOR DRAIN
MECHANICAL FEES
1/L 0 �/ 7
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 1+/e c
SEWAGE DISPOSAL
INSULATION/SOUND
FINISH GRADING
SO.FT.GAR ® 3/ac
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLU
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE /6 /
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS�Q
EWE R P
ROUGH WIRING
DUCT WORK
ROCKSTORAGE
FOUND. REINF. /�
GAS (ROUGH) Q�
77
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL �� p 9s
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
�1 /
FINAL INSP. 3 i% x(o
FRAMING
FINAL INSP.
ROOFING
1/L 0 �/ 7
REMARKS:
VENTILATION
FIRE ZONE ROOFING '
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION il6
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESJINITIALS
GARDEN WALL FINAL
Residence Address: Seasons Apartments Btiildinq ZS
50-4390 Pnrarl►�REr,,tT)-iNe L,Qtjw4n,CAq-22S3.
CERTIFICATION. This is to certify char artic iniulanon.!:as ! een insralledin ol sformance with
the cos'1e'ra�( . m
,hart aecomendations on theopposite <ide of t`•:s : and using L bags to
cover sq. fc to obtain an R -value of 38
Cont, es authored ii;nature 1-4/ P Eoix,
Date 1311AG
Installed bre Builder
ROVER INSULATION
7¢741 10NI DRIVE
PALM DESERT, CA 92260
-(6191 34W-44,DW
TW /MS"rloN SPECIALIST)
R -PRO- PLUS
(F;Smierly
STABILIZED INSULATION
MANUFACTURED BY
GREENSTONE INDUSTRIES
Atlanta, Georgia • Elkwood. Virginia • May Indiana
Norfollr• Nebras{ca •Phoenix, Arizona • Pbriland, Oregon
ATOMIZED PNEUMATIC APPLICATION COVERAGE.CHART
R -Value at
1 25.3
Net coverage
No AQustment for Trusses
Gross
75-FBased
Mean
1 39.7
on 2 x tr
Maximum
Minimum
Tempe2turo rrq
ThdInese
Trusses on If'
Net
Weight Per
Center
Coverage
Square.Foot
To Obtain
Installed
Square
Minimum
The Weight Per
Suare
Bags .
An Insulation
InsuWtiott
:Feet
Bags
Sq. Ft. of.
Feet.
Required
Resistance
Should Not
Per
Required
Installed
Per
Per :1,000
.(R) of
Be Lass Than
Bag
Per.1.000
InsuLation Should
Bag
Square Feet
(inc)ti:s)
Square Feet
Not Be Less
Than: fibs)
R-50
13.5
20.5
48.8
1.464
21.3
46.9 .
R-42
11.4
24.4
41.0
1.230
.25.6.
39A
`R-40
10.8
25.6
39.0
1:172
26.9.
37.2
R-38
10.3
27.0
37.1
1.113
28:4
35.2
R-32
8.6
32.0
34.1
.937 ,
" 34.1
29.4
R-30
8.1
34.2
' 29.3
.878
36.5
-27.4
R-24
6.5
42.7
23.4
.703
46.4
.21.6
R-22
5.9
46.6
21.5
.644
51.0
19.5
R-19
5.1
53.9
18.5
.556 '
59.6
16.8
R-13
3.5
78.8
12.7
.381
87.0
11.5
R-11
3.0
93.2
10.7
322
102.8
9.7
Sidewalls (pressure Filled -density 2.6 _PPCF)
-13 (2 x4)
3.5 39.6
1 25.3
.758
R-20 (2 x 6)
5.5 1 25.2
1 39.7
1.192
Note: This coverage chart compensates for settling and is for estimating purposes only.
Stated R -Value is provided by installing the required number of bags per 1.000 sq. ft. at a
minimum installed thickness: Installation of the required number of bags may yield more
than the specified minimum thickness and minimum weight per sq. ft. Actual coverage wi8
be influenced by job conditions and application techniques, and may vary as much as 10%
without significantly affecting the stated R -Value. Failure of the installer to provide at least
the required number of bags per. 1000 sq. ft. and at least the minimum thickness may result
in a lower installed R -Value after settling. Compaction may occur during installations above R-
30 recuirinq more than the stated number of bags to obtain the minimum installed thickness.
i
This home is insulated with
Fiber Glass Blankets when
installed according to the
manufacturer's recom-
mendations will provide the full
rated thermal resistance value.
T6'me'et the thermal resistance .value (F3), the manufacturer has specified the number of bags per. .
1000 sq. ft. of net area that must be installed to meet both the minimum design thickness and
minimum wt./sq. ft. requirements. Installing the correct number of bags/ 1000 sq. ft. is necessary to
meet the corresponding labeled resistance (R) value. (Based on 40 Ib. nominal net weight bag).
Rich -RT"' Fiber Glass Blowing Wool Attic Insulation -40 lb. Bag.
A
Blanket Insulations
R
Bags per Maximum Minimum.
Minimum
In11011W
24.8 r:
R Minimum
Valuet
1000 sq. ft. � Wet Wt./sq. ft..
Thickness
Thldtness
�::�^
Value Thickness
--
To obtain
The number of Contents The weight
Installed
Average
ri
;,Y� ; a
To obtain an Installed
an insula-
bags per 1000 of this bag per sq. ft hof
insulation
.,
installed
12.3
insulation insulation
tion resis-
sq. ft. of net should not installed insul-
should
thidtr198p
2x8
resistance should
-tance
area should not cover ation should not
not be
will
7.1
(R) of: not be less than:
(R) of:
be_ less.than: more than: be less than:
less than:
Batts and rolls have been installed in conformance with the above
}�
R-38 13" Thick'
R-44
291/2 34 sq. ft. 1.188_lbs.
15" Thick
ley
�:;v�•�•y
R-30 9!'4" Thick'
R-38
251/2 39 sq. ft. 1.029 lbs.
13" Thick
141/4"
ti.t
_
R-26 ti�ia"Thick
R_-30
20'/2 49sq. ft. 0.811 lbs.
101/4" Thick
111/4,
' 1.
_
R_-22 71/2" Thick
R-22
15 67 sq. ft. 0.594 lbs.
71/2" Thick
I,
_
R-19 61/2" Thick'
R-19
13 78 sq. ft. 0.514 lbs.
61/2" Thick
71/4"
R-13 3w6" Thick"
R-11
�
7 /2 135 sq. ft. 0.297 lbs.
33/4" Thick
41/4"
R-11 2" Thick 3 /
' _..•__
TMS{
Rich -RT" Fiber Glass Blowing•WooF 5idewall Insulation -40 -Ib. Bag.
'
"Thickness varies, check bag
R-16
16V2 60 sq, ft. 0.667 lbs,_
4" Thick
4"
v
'
label for producing locations
R-14
15 66 sq. ft. 0.604 lbs.
3%" Thick .
344"
. �..`Si
thickness.
**R-12.7
- -
R=14
141/2 68 sq. ft. 0.583 lbs.
31/2" Thick
W
`AK
in a 3'/2' cavity.
1
Average installed thickness is provided as a guide to installers. Actual thickness will vary
9 P 9 r1/
:.
Seasons Apartments
depending on conditions at the time of installation. To obtain a specific R -value, insulation
4'
Building
should not be applied over;a larger area than specified on the coverage chart.
La Quints, CA 92253
Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of
-ctrl
:
Federal Specification
1 -1-10300: Type.1, Class B, and DOE RCS
Standards. Also "sets
044
5 Q- 93qo i1Qi''L'cj-se. S}fir,
Insulation Quality Standards of the State of California.
;
Framing Correction for 40 Ib.
R
Framing 16" on center.
Joists 1000 ft.
Framing 24" on ,.
^`f
Bag Rich -R Blowing Wool
Bags per sq.
Bags per 1000
sq. K
tk-
Valuest
Dimensions (gross)
(gross)
When installing in attics of new
R-44
2x8 28.2
28.6
homes or existing homes where
no insulation is present, it is
2x6 28.5
2x4 28.9
28.8
bl d h
29.1
accepta a to a lust t e
coverage figures to compensate
for the presence of the framing
members as indicated in the
following table.
R-38 2x8
24.2
24.6
2X6 '
-.24.5
24.8 r:
2x4
? 24.9
25.1
R-30 2x8
`19.1
19.6
2x6
19.5
198
_
2x4
19.8
20.1
R-22
2x8
13.6
14.1
tR-values indicated obtained
2x6
2x4
14.0
14.3
14.3
14.6
when properly installed with -
pneumatic equipment. R-19
2x8 _
11.8
12.2 l;
2x6
12.0
12.3
The higher the R -value, the
2x4
12.3
12.6
greater the Insulating power. R-11
2x8
6.8
7.1
Ask your seller for the fact sheet :.`•
2x6
6.8
7.1
on R -values.
2x4
6.8
7.1 !
Batts and rolls have been installed in conformance with the above
Blowing wool has been installed
in the ceiling or sidewall in Cori- "
recommendations to provide a thermal resistance value of..
formance with the above recommendations to provide an R -value.:
R- 35_-. at .__-_. __. inches in 9t; sq. ft. of ceiling, R- 13 at
of R- using
bags of this insulation to cover .
_ inches in Wq, sq. ft. of exterior walls, and R
at
square feet of area
inches in... sq. ft. of floors or crawl space perimeter.
minimum thickness of
inches.
Date Signature
31 (o lqf n, jt
Date Signature
MIG -6t6 7166
Contractor
74-741 Joni Drive
PALM DESERT, CALIFORNIA 92260. a
(4119) 346-2339 wined a, t►SAa' �!