Loading...
15470 (SATT)Buildir Addre: Owner E.G. Williams Dev Mailing Address 42-600 Cook St. City Zip P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 No. 15470 BUILDING: TYPE CONST. VN OCC. GRP. R1 Suite 120 'A.P. Number Palm Desert,, -CF 2221 Contractor Saone Address el. (61911341-6880 Legal Description Lot 1 Tract 28019 Project Description SPA — Apartment P"Lan 1 Senior Housing at The Seasons State Lic. I City & Classif. Ea, 493919 Lic. # 1231 Arch., Engr., Designer Stoffigren FuAll er & Associates Address Tel. 68-487 E. Palm Canyon (619)328-1801 City Zip State Cathedral City* CA 92234 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section. 7000) of Division 3 of the Business and Professions Code, and my licen�is in full.forccCe,and effect_ SIGNATURE 'x" DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I,as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. g, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or Improve for the purpose or sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to torr . • struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law ;3? does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) pcensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3900, Labor Code.) Pglicy No.Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., ft, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. WARNING: FAILURE To SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL; AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that 1. have read this application and state that the'above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above. mentioned property for Inspection purposes. Signature of applicant -Date- Mailing ateMailing Address City, State, Zip Sq. Ft. No. Size 609 Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ (Estimated valuation $310-424.00 PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS AMOUNT 271.68 297.50 49.00 78.83 108.00 3.14 20: Q .04 707.04 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear�r p. ine Side Street Setback fro, enter ' e Side Setback from Prod y Li FINAL DATE ECT 10 Issued by Validated Validatior CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBINU FIEES''--�"''- 1ST FL. SO. FT. ® $ UNITS.• ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK YARD SPKLR SYSTEM 2ND FL. SQ. FT. DUCT WORK ROCK STORAGE FOUND. REINF. 9 f MOBILEHOME SVC. BAR SINK POR. SO. FT. ® REINF. STEEL �� 7J GAS (FINAL) TEMP. POLE GAR. SO. FT. ® POWER OUTLET ROOF DRAINS WATER HEATER SERVICE FINAL INSP. DRAINAGE PIPING CAR P. I SQ. FT. WATER SYSTEM GRADING Cu. yd. $ plus x$ WALL SO. FT. LUMBER GR. DRINKING FOUNTAIN. SQ. FT. ® FINAL INSP. URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation VENTILATION FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 C SEWAGE DISPOSAL FINAL INSPECTION p SO.FT.GAR ® 3/ac HOUSE SEWER CERT. OCC. 3 FENCE FINAL - GAS PIPING PERMIT FEE INSPECTOR'S SIGNATURES11NITIALS PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBI �� UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE �� �� 9J ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS ��J �� fJ EWE OR ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. 9 f GAS (ROUGH) METER LOOP !� HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL �� 7J GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING Cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING a REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING 9� MESH INSULATIONISOUND 2 �9 FINISH GRADING FINAL INSPECTION p CERT. OCC. 3 FENCE FINAL - INSPECTOR'S SIGNATURES11NITIALS GARDEN WALL FINAL 14t) 'tc"'t �"O-Xtz %zitrT of (9'e-r7rip-IL _'_ ijCg Tt t of 14'a - (Qlttnta it t This Certificate issued pursuant to the-repyirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 50 -740 -Paradise East Dr. A Use Classificotion SFA - Apartment Bldg. Permit No. 15470 Group ' R-1 Type Construction VN -Fire Zone Use Zone R-1 42-600 Cook St. Suite 120 E.G. Williams Development Owner of Building Address C1 Pa Desert, CA. , 92211 Date; March 21, 1996 Building Official POST IN A CON8VICU009 PLACIE Daniel P. Crawford Jr. By; Residence:Addmss: Seasons Apartments Bud1dinq 20 60 %W OWN M Wo bm e a W& CERTIFICATION This is to certify that attic insulanon has �«n installed in confortnanm with the ' coverage chat ecommendations on the opposite <idc of ,h:s :ard using 2 bags to cover I I J sq. ft_ to obtain an R'-vlalueof 33 Contractor's audwrxai si;nlature tiro I Date 1;f (e /9 14 Installed hr. Builder ROVER INSULATION 74-741 3ON1 DRIVE PALM DESERT, CA 92260 -2339 ,THE ff#Wi-A710X SPECIALIST) . R -PRO PLUS (Formerly Cordc>J STABILIZED INSULATION .MANUFACTURED BY GREENSTONE INDUSTRIES Atlanta, Georgia • Elkwood, Virginia • ft Wayne, Indiana Norfolk, Nebraske •Phoenix, Arizona Porila17 Oregon ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART Net coverage R -Value at No A�tmrneru for Trusses ased 2� Mean Msnurxrrn on Maim Minimum ernp Temperatuie ThKkness Trusses on 1e• : Net WegM Per Centers Coverage Square. Foot To obtain Instaved 901 -ft Minimum The Weght Per Suare Bags an Insulation Insulation Feet sags. Sq. Ft. at Feet. Required Resistance Should Not. Per Required Installed Per Per 1.000 .(plot Be Less Thw Bag .. Per 1.000 Insulation Should Bag Square Feet (inures) Square Feet Not Be Less Than: (Ibs) R-50 13.5 20.5 48.8• 1.464 21.3 •46.9 .. R-42 11.4 24.4 41.0 1.230 25.6 39.1 R-40 10.8' 25.6 39.0 1.172 26.9 37.2 R-38 .10.3 27.0 37.1 1.113 28:4 35.2 R-32 8.6 32.0 34.1 ..937; 34.1 29.4 R-30 8.1 34.2 29.3 .878 36.5 27.4 R-24 6.5 42.7 23.4 .703 46.4 21.6 R-22 5.9 46.6 21.5 .644 51.0 19.5 R-19 5.1 53.9 18.5 .556 - 59.6 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 R-11 3.0 93.2 10.7 .322 102.8 9.7 Sidewalls (pressure Filled -density 2.6 PPCF) -13 (2 x4) 3.5 39.6 25.3 .758 R-20 (2.x 6) 5.5 25.2 39.7 1.192 . Note: This coverage chart compensates for settling and is for estimating purposes only. Stated FI -Value is provided by instalfirtg the required number of bags per 1000 sq. ft at a minimum installed thickness. Installation of the required number of bags may yield more than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will be influenced by job conditions and application techniques, and may vary as much as 10% without significantly affecting the stated R -Value. Failure of the installer to provide at least the required number of bags per 1000 sq. ft. and at least the minimum thickness may result in a lower installed R -Value after settling. Compaction may occur during installations above R- 30 recuirinc more than the stated number of bags to obtain the minimum installed thickness. with �Illls tr -Y Fiber Glass Blankets when To meet the thermal resistance value (R), the manufacturer has specified the number of installed according to the 1000 sq. ft. of net area that must be installed'to meet both the minimum design thickness manufacturer's recom- minimum wt./sq. ft. requirements. Installing the correct number of bags/ 1000 sq. ft. is nt mendations will provide the full meet the corresponding labeled resistance (R) value. (Based on 40 Ib. nominal net weig rated thermal resistance value. -- ru ' Blanket Insulation R Minimum Value _ Thickness To obtain an Installed insulation insulation resistance should (R) of: _ not be less than: R-38 13" Thick' R-30 -- 9V4 Thick R_26 _ 8�ia" Thick R-22 _71/2" Thick R_19_ 61/2" Thick' R-13 35/e" Thick - R -11 31/2" Thick "Thickness varies, check bag label for producing locations Rich -R Fiber Glass Blowing Wool Attic Insulation --m IN. Bag. K! per R Bags per Maximum Minimum Minimum Installed Building LQ Valuet 1000 sq. ft. Net Coverage WUsq. ft. Thickness Thkknps -: To obtain The number of Contents The weight Installed Average Valuest Dimensions (gross) (gross) an insula- bags per 1000 ' of this bag per sq. ft hof insulation installed acceptable to adjust the tion resis- sq. h: of net should not installed insul- should thickness '':: •s tance area should not cover ation•should not not be will (R) of: -_ be less than: more than: be less than: less than: typically be:. R-44 2912 .34 sq. ft. 1.188.lbs. 15" Thick 181/2" _ R-38 _ _2_51/2 39 sq. ft: 1.029 lbs. 13" Thick 141/4" "' .:...• R_-30 201/2 49 sq. ft. 0.811 lbs. 101/4" Thick 111/4" R-22_ 15 67 sq. ft. 0.594, lbs. 71/2" Thick 81/4" R-19 13 78 sq. ft. 0.51.,4 lbs: 61/2" Thick 71/4" R-11 7Y2 135 sq. ft. 0.297 lbs. 334" Thick 41/4° Rich -RT'" Fiber Glass Blowing Wool Sidewall Insulation--40-Ib. Bag. R_-16 161/2 60 sq. ft. 0.667 lbs. 4" Thick 4'r R -14 15 66 sq. ft. 0.604 lbs. 3%" Thick - 34fa" thickness. , ;° 31/2" Thick 31/2" '' R-14 14 /z 68 sq. ft. 0.583 lbs. R-12.7 in a 3Y2" cavity. Average installed thickness isrovided as a guide to installer4. Actual thickness will vaty Seasons Apartments depending on conditions'at the time of installation. To obtain a specific R -value, Insulation Building LQ should not be applied over a larger area than specified on the coverage chart. La Quinta, CA 92253 Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of 14:3 Federal Specification HH -1-1030B. Type 1, Class B, and DOE RCS Standards. Also meets SD- -74c) Insulation Quality Standards of the State of California. Framing Correction for 40 Ib. Framing 16" on center. Framing 24" on cental:. ., Bag Rich -R Blowing Wool R Joists Bags per 1000 sq. ft. Bags per 1000 sq. ft. 11.8 Valuest Dimensions (gross) (gross) When installing in attics of new R-44 2x8 • 28.2 28.6 homes or existing homes where 2x6 28.5 28.8 no insulation is present, it is 2x4 28.9 29.1 ' acceptable to adjust the -' .'13,L1` coverage figures to compensate R-38 2x8 24.2 24.6 for the presence of the framing 2x6 ' • 24.5 24.8 ate, members as indicated in the 2x4 24.9 25.1 following table. R-30 2x8' 19.1 19.6 ' on Fl -values. .2x6. 19.5 19.8 6.8 2x4 19.8 20.1 R-22 2x8 13.6 14.1 t 2x6 14.0 14.3 tR-values indicated obtained 2x4 14:3 14.6 when properly installed with - pneumatic equipment. R-19 2x8 11.8 12.2 2x6 12.0 12.3 The higher the R -value, the 2x4 12.3 12.6 greater the insulating power. R-11 2x8 6.8 7.,1, Ask your seller for the fact sheet 2x6 6.8 7:T on Fl -values. 2_x4 6.8 7.1 Batts and rolls have been installed in conformance with the above recommendations to provide a thermal resistance value of R-3&_at _-... -._. inches in 9 ° ..0 sq. ft. of ceiling, R - at inches in (O3� sq. ft. of exterior walls, and R ___._-_ at inches in....--- sq. ft. of floors or crawl space perimeter. Date Signature a (0 �vt4 Data S.pnature HiG-M 7166 Blowing wool has been installed in the formance with the above recommends of R- using bags of this minimum thickness of inches. or sidewall in cors - i provide an R -value ion to cover a fare feet of area Insulation Contractor . 74-741 Joni Drive PALM DESERT, CALIFORNIA 92260 =; ih19) 346-2339 Prwasd.intSi►::_ ResidenceAddress Seasons Apartments Building 20 &-Agt) Phrcidi e EmI D- ye) Lr Duinf a ,O A 92253 CERTIFICATION: This is to certify that attic insulanon has ! Cin installed in conformance with the coverage chart recommendations on the opposite <i:1e of this card using Li 2. bags m cover 11 Jq sq. ft m obtain an lk-v�aluenof 33 Contrxrot's au=hori:ed signature Fi'f}. l� 1 Dam 3/ 1 e J'7 W Installed bv. Builder ROVER INSULATION I¢741 JONI DRIVE PALM DESERT, CA 92260 (6MI 346--2339 'TIE nvSuI ATION SPECIALIST) R -PRO PLUS (Formerly Corded ; STABILIZED INSULATION +- MANUFACTURED BY GREENSTONE INDUSTRIES Atlanta, Georgia • E1klavood, Virginia • Fc Wayne, Indiana Norfolk, Nebraska •Phoenix, Arizona Portland. Oregon ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART Net cavera" R -Value al No A*strr*M for Trusses Gross Cove" 75'F Mean Mbtvtern Based on 2 x 8• Max mutn Minimum Terfpe2Nro ThK*ness Trusses on 1 ir• Net weight Per Centers Coverage Square Foot To Obtain Instaled Square Minimum The Weight Per Suare Bags an Insulation Insulation Feet Bags Sq. Ft. of. Feet. Required Resistance Should Not Per Required Installed Per Per 1.000 .(slot Be Less ThW Bag Per 1.000 Insulation Should Bag Square Feet (irises) Square Feet Not Be Less :. Than: (Ips) R-50 13.5 20.5 48.8 1.464 21.3 46.9. R-42.. 11.4 24.4 41.0. 1230 25.6 .39.1 R-40 10.8 25.6. 39.0 1.172 26'.9 37.2 R-38 10.3 27.0 37.1 1.113 28:4 35.2 R-32 8.6 .32.0 34'1 .937. 34.1 29.4 R-30 8.1 .34.2 29.3 .878 36.5 27.4 R-24 6.5 421 23.4 .703 46.4 21'.6 R-22 5.9 46.6 21.5 .644 51.0 19:5 R-19 5.1 • 53.9 18.5 .5667. , '59.6 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 R-11 3.0 93.2 10:7 .322 102.8 9.7 Sidewalls (pressure Filled -density 2.6 PPCF) -13 (2 x4) 3.5 39.6 25.3 .758 R-20 (2 x 6) 5.5 .25.2 39.7 1.192 Note: This coverage chart compensates for settling and is for estimating purposes only. Stated R -Value is provided by installing the required number of bags per 1000 sq. ft- at a minimum installed thickness. Installation of the required number of bags may yield more than the specified minimum thickness and minimum weight per sq. ft. Actual coverage wil be influenced by job conditions and application techniques, and may vary as much as 1.0% without significantly affecting the stated R -Value. Failure of the installer to provide at least the required number of bags per 1000 sq. ft. and at least the minimum thickness may result in a lower installed R -Value after settling. Compaction may occur during installations above R- 30 rroeuiHnq more than the sta!ed number of bags to obtain the minimum installed thickness. thickness. .This -horne is Insulated with, 13.6 ••R-12.7 in a 31/2" cavity. Average installed thickness is provided as a guide to installer4. Actual thickness will vary 2x6 Seasons Apartments depending on conditions at the time of installation. To obtain a specific R -v tFl-values indicated obtained Building 2Q should not be applied'over a larger area than specified on the coverage chart. 14.6 La Quinta, CA 92253 Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of Federal Specification 1-11-14-1030B. Type 1, Class B, and DOE RCS Standards. Also amte 2x8 ) - C qc) -D� Insulation 0.tiality Standards of the State of California. Framing Correction for 40 lb. Framing 16" on center. Framing 24" on cenUW, 12.3 Bag Rich -R Blowing Wool R Joists Bags per 1000 sq. ft. Bags per 1000 sq. fL 12.3 12.6 Valuest Dimensions (gross)- (gross) 2X8 When installing in attics of new R-44 2x8 28.2 28.6 2 homes or existing homes where Fiber Glass Blankets when To meet the thermal , resistance value (R), the manufacturer has specified the number of per no insulation is present, it is installed according to the 1000 sq. ft. of net area that must ' be installed to meet both th&rnihimum design thickn coverage figures to compensate manufacturer's recom- minimum wt./sq. ft. requirements. Installing the- correct number of bags/1 000 sq. ft. is to members as indicated in the mendations will provide the full meet the corresponding :lab I eled resistance (R) value. (Based on 40 lb. nominal net Weig t bag). R-30 2x8 19.1 19.6 rated thermal resistance'value. Rich-RIAFiber Glass Blowing Wool Attic Insulation -40 lb. Bag. 2x4 19.8 20.1 ry Blanket Insulation R Bags per Maximuni Minimum'. Minimum Average IrtsMllatd R Minimum Valuet 1000 sq. ft. Net Coverage 'Wt./ sq. ft; Thickness ThIclaw" Value Thickness TO 'obtain The number of Contents' - The weight Installed Average To obtain an Installed :an insula- bags per 1000 of this bag per sq..tt."of insulation installed insulation insulation tion resis- sq. ft. of net should not installed insul- should thickrim: resistance should tance area should not; cover ation should not not be will (R) of: not be less than: (R) of: beless than: more than:_ beless than: less than: typically be: 13" Thick' R-44 291/2 .34 sq. ft. 1.188 lbs. 15" Thick R-30 91A Thick' -R-38 2_51/2 39 sq. ft. 1.029 lbs. 13" Thick 141/4 R-26 __._.8J/4' -'_Thick_ R-30 201/2 49 sq. ft. 0.81l,1bs. 101/4" Thick 111/4 R -U 711Y' Thick R-22 15 67 sq. ft. 0.594 lbs. 71/2" Thick 81/4" R-19 61/2" Thick* R-19 13 78 sq. ft. 0.51,� lbs. 61/2" Thick 71/4""' R-13 3S/ki" Thick- R-11 71/2 135 sq. ft. 0.297 lbs. 33/4" Thick 41/4 4" R-11 31/2" Thick Rich -R"' Fiber Glass Blowing Wool Sidewall Insulation -40 -lb. Bag. "Thickness varies, check bag R-16 161/2� 60 sq ft. 0.667 lbs. 4" Thick 4" labial for producing locations R-14 15. 66 sq. ft. 0.'604 lbs. 3%" Thick thickness. R-14 141/2 68 sq. 1`16 0.583 lbs: 31/2" Thick 3Y20 13.6 ••R-12.7 in a 31/2" cavity. Average installed thickness is provided as a guide to installer4. Actual thickness will vary 2x6 Seasons Apartments depending on conditions at the time of installation. To obtain a specific R -v tFl-values indicated obtained Building 2Q should not be applied'over a larger area than specified on the coverage chart. 14.6 La Quinta, CA 92253 Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of Federal Specification 1-11-14-1030B. Type 1, Class B, and DOE RCS Standards. Also amte 2x8 ) - C qc) -D� Insulation 0.tiality Standards of the State of California. Framing Correction for 40 lb. Framing 16" on center. Framing 24" on cenUW, 12.3 Bag Rich -R Blowing Wool R Joists Bags per 1000 sq. ft. Bags per 1000 sq. fL 12.3 12.6 Valuest Dimensions (gross)- (gross) 2X8 When installing in attics of new R-44 2x8 28.2 28.6 2 homes or existing homes where 2x6 26.5 28.8 no insulation is present, it is 2x4 28.9 29.1 6.8 acceptable to adjust the R-38 2x8 24.2 24.6 coverage figures to compensate for the presence of the framing 2x6 24.5 24.8 members as indicated in the 2x4 2.4.9 25.1 following table. R-30 2x8 19.1 19.6 2x6 19.5 19.8 1 2x4 19.8 20.1 R-22 2X8 13.6 14.1 2x6 14.0 14.32x4 tFl-values indicated obtained 14.3 14.6 when properly installed with pneumatic equipment. R-19 2x8 11.8 12.2 2_x6 12.0 12.3 The higher the R -value, the 2x4 12.3 12.6 greater the insulating power. R-11 2X8 6.8 71 Ask your seller for the fact sheet 2x6 6.13 on Fl -values. 2x4 6.8 7.1 Batts and rolls have been installed in conformance with the above recommendations to provide a thermal resistance value of Fl -.3 �L at ___'inches in q 6 sq. ft. of ceiling, Fl- at inches in 103 sq. ft. of exterior Walls, and at inches in sq. ft. of floors or crawl spac e perimeter. Date Signature .3](0q6. /i-rOj)eolm Date Signature HIG-616 7186 Blowing wool has been installed in the ceili formance with the above rectommendation of R_ using - bags of this inSL minimum thickness of - inches. or skiewall in ctort- i provide an R -value Y ion to cover Liare feet of am ig a InsulationContractoir ROM mul I INA11? a A. In 7. ' 4 I 441 Joni Drive PALM DESERT CALIFORNIA 92260 (4 Iq i 346-2339 pritirtitod in VU." Fiber Glass Blankets when installed according to the manufacturer's recom- mendations will provide the full rated thermal resistance value. Blanket Insulation R Minimum Value _ Thickness To obtain an Installed insulation insulation resistance Should per sq. ft. of _not be less than: -� _ R-38 - 13" Thick' R -30J 9v."Thick' R-26 8+4" Thick la-� 71/2" Thick R_19__- 61/2" Thick' R-13 3!va" Thick - R -11 31/2" Thick 'Thickness varies, check bag label for producing locations thickness. This. home- Is insulated with Ser uidbb It IbUk� To meet the thermal resistance value (R), the manufacturer has specified the number of 1000 sq. ft. of net area that must be installed to meet both the minimum design thickness minimum wt./sq. h, requirements. Installing the correct number of bags/1000 sq. ft. is nE meet the corresponding labeled resistance (R) value. (Based on 40 lb. nominal net weig Rich -RIM Fiber Glass Blowing Wool Attic Insulation -40 Ib. Bag, R Bags per Valuet 1000 sq. ft. Minimum Minimum Wt./sq. ft. Thicknes "V Weary, to bag). To obtain The number of Contents The weight Installed 14.0 14.3 an insula- bags per 1000 of this bag per sq. ft. of insulation Installed Federal Specification HH -i-10308. Type 1, Class, B, and DOE RCS Standards. Also nf80t8 ! tion resis- sq. ft. of net should not Installed insul- should thickftssg Framing Correction for 40 lb. Lance area should not cover ation should not not be will R-� 2x8 28.2 28.6 (R) of: be less than: more than: be less than: less than: 20 28.9 29,1 R-44291/2 acceptable to adjust the coverage figures to compensate .34 sq. ft. 1.188113S. 15" Thick - 2x6 24.5 24.8 <; 2x4 24.9 25.1 members as indicated in the R-38 251/2 39 sq: ft. 1.029 lbs. 13" Thick 141/4" 2x6 19.5 19.8 R-30 201/2 49 sq. ft. 0.811 lbs. 10V4" Thick 11%11 R-22 15 67s ft. 0.594 lbs. 71/2" Thick 81/4" R-19 13 78 sq. ft. 0.51.4 Ibs. 61/2" Thick T/." R-11 71/2 135 sq. ft. 0.297 lbs. 4" Thick 41/4" Rich__-R;M Fiber Glass Blowing Wool Sidewall Insulation --404b. Bag. "4 R-16 161/2 60 sq. ft. 0.667 lbs. 4" Thick 4" :r R-14 15 66 sq. ft. 0.604 lbs. 3%" Thick R-14 141/2 68 sq. ft. 0.583 lbs. 31/2" Thick 31/" -'R-12.7 in a 31ia' cavity. Average installed thickness is provided as a guide to installers. Actual thickness will vVy 14.1" Seasons Apartments depending on conditions at the time of Installation. To obtain a specific R -value, Insulstlm 14.0 14.3 not be applied over a larger area than specified on the coverage chart 2x4 Build Building 2_10 Net wt./bag, minimum 37 lbs. This product conforms to the performance requirements of Net ing CA 92253 L.3 Federal Specification HH -i-10308. Type 1, Class, B, and DOE RCS Standards. Also nf80t8 ! 12.2 SC> -j qC) rU (bd e0j- e- Insulation Duality Standards of the Stats of California 12.0 12.3 Framing 16" on center. Framing 24" on cwvW. Framing Correction for 40 lb. R Joists Bags per 1000 sq. ft Bags per 1000 sq. fit 12.6 Bag Rich -Ft Blowing Wool Valuest Dimensions (gross) (gross) 6.8 When installing in attics of newr R-� 2x8 28.2 28.6 2x6 homes or existing homes where 2x6 28.5 28.8 �' Y no insulation is present, it is 20 28.9 29,1 , acceptable to adjust the coverage figures to compensate -� R-38 2x8 24.2 24.6 .` for the presence of the framing - 2x6 24.5 24.8 <; 2x4 24.9 25.1 members as indicated in the following table. R-30 2x8 19.1 19.6 2x6 19.5 19.8 2x4 19.8 20.1 tR-values indicated obtained when properly installed with pneumatic equipment. The higher the R -value, the greater the insulating power. Ask your seller for the fact sheet on R -values. R-22 2x8 13.6 14.1" 2x6 14.0 14.3 2x4 14.3 14.6 R-19 2x8 11.8 12.2 •'" 2x6 12.0 12.3 2x4 12.3 12.6 R-11 2x8 6.8 7.11, A 2x6 6.8 7 �' Y 2x4 6.8 Batts and rolls have been installed in conformance with the above Blowing wool has been installed In the cetll or sldewail 1/t con - recommendations to provide a thermal resistance value of formance with the above recommendation 0 provide an R-veks. R at inches in y sq. ft. of ceiling, R-_14 at of R- using bags of -this insu tion to cover ..._ __....._. inches in I Q3ke sq. ft. of exterior walls, and R ___._ __ at -- uare feet of ares at s •'" inches in.- _..- sq. ft. of floors or crawl space perimeter. minimum thickness of inches. Date S,analure A Osla S.ynatula insulationConuaetor 74741 iCM Yif1Y! PALMOE RT. CALIFORNIA 92260 MiG6t6 7186 tq) 346-2339 Wintsd in WA ^ 'ss Residence,4A6m Seasons Aprlrtwnts Building 20 SuNbt'nai�st�riVP� Ui[�l�in�Q,CAQ�3 CERTfRCATUSi k This is to certify thatattic rniulinon !less 4trn installed in conformance with the coverage diart seeommemlations on the opposite <ide 4 tFts card usinj `i Z bap to ewer 11 st} ft to obtain an !,-`vlalluer`of 38 C.xttt�cmrs ataittx�stl signature f t(LY 1 Dace ,7i o l4 to Installed Rutl.ier. ROVER INStliLATION 1&-741 3= t]3i1VE pALM DESM, CA 92260 TW I ATRW SPECIALIST) K-j!RO PLUS (Rkmerly Corde>J 51ABILIZED INSULATION MANUFACTURED BY GREENSTONE INDUSTRIES Atlanta, Georgia • Qkwlood• Virginia • Ct Wayne, Indiana Norfotk, Nebraska • PMenix• Arisona • tbrtland. Oregon ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART ai No cave" N0 A4usun&n! for Tnrsset Mean nknip-value N.m Based an 2 x a' Mangum Minimwrn rip Twer►peraturo wilm d Trusses on i r Not Wei" Per CerRers Covera" Square Foot To Obtain It SMW $guar! Minttmun The WegN Per Suare Bags an Insulation trauladon Feet Sags S4 Ft. of Feet. Required Resistance Shald No Per Required tnstased Per Per 1.000 •tA) of Be LOU owbag Per 1.000 nsulaowt Should Bap Sir"m Feet (incites) Square Fest Not Be less Than: (Ibs R-50 13.5 20.5 48.8 1.464 21.3 46.9 R-42 11.4 24.4 41.0 1.230 25.6 39.1 R-40 10.8 25.6 39.0 1.172 26.9 37.2 R-38 10.3 27.0 37.1 1.113 28:4 35.2 R-32 8.6 32.0 34.1 .937 34.1 29.4 R-30 8.1 34.2 29.3 .878 36.5 27.4 R-24 6.5 42.7 23.4 .703 46.4 21.6 R-22 5.9 46.6 21.5 .644 51.0 19.5 R-19 5.1 53.9 18.5 .556 59.6 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 3.0 93.2 1 10.7 .322 102.8 9.7 Sidewalk (pressure Filled -density 2.6 PPCF) •13 (2 x4) 3.5 39.6 1 25.3 .758 •20 (2x6) 5.5 1 252 1 39.7 1. 192 Note: This coverage draft eontpensattes for settling and is foe estimating purposes only. Slataed R -Value is presided by iristaw, the required ntrnber of bags per 1000 sq. R at a minimum installed thickness. Installation of the required number of bags may yield more than the specified minimum thickness and minimum weight per sq. ft. Actual coverage will be influenced by job conditions and application techniques, and may vary as much as 106 without significantly affec*V the stated R -Value. Failure of the installer to provide at least d* required number of bags per 1000 sq. ft. and at least the minimum thickness may result in a lower installed R -VA* after settling. Compaction may occur during installations above R- 30 recuirino more than the stated number 31 bags to obtain the minimum installer! thickness.