13-1098 (SFD)15,
P.O. BOX 1504 •
4
78-495 CALLE TAMPICO /✓
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 13-00001098. Owner:
Property Address: 81347 COLUMBUS WY DISCOVERY LAND
APN: 767-200-998-12 -330762- 80955 AVE 52
Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL LA QUINTA, CA 92253
Application valuation: 394160
Contractor:
Applicant: Architect or Engineer: DBCA INC
P.O. BOX 1482
LA QUINTA, CA 92247
Cd 7 Yz�-. 16 2_ 1" I� Lic. No.:5
271
N 915336
------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business a4Professis Code, and my License is in full force and effect.
License Class:B icense to: 915336
Dat ✓ //,yContractor:LDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's'State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1— 1 1 am exempt under Sec. , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.)•
Lender's Name: _
Lender's Address:
LQPERMIT
=10
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/28/14
---------------------------------------=-------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier TRAVELERS Policy Number YJUB282D7797-12
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if 1 should become subject to orkers' clApensation provisions of Section
3700 of the Labor Code, I shall forthwith - mpj with th9te provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPEN ATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES A D CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and ereby author' a representatives
of this county to enteruponthe above-mentioned propert for inspection p ose
Date Signature (Applicant or Agertt �r —,--.-
Application Number . . . . . 13-00001098
------ Structure Information NEW SFD
-----
Other struct info . .
. . . CODE EDITION
2010
# BEDROOMS
4.00
FIRE SPRINKLERS
13D 5276 SQ.
GARAGE SQ FTG
946.00 '
PATIO SQ FTG
1262.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
4330.00
Permit
. . .
BUILDING 2013
Additional
desc . .
Permit Fee
. . . .
682.63 Plan Check Fee
.00
Issue Date
Valuation
394160
Expiration
Date
8/27/14
Qty Unit Charge
Per
Extension
BASE FEE
573.43
195.00
----------------------------------------------------------------------------
.5600
THOU BLDG $200,001-$1M
109.20
Permit
. . .
ELECTRICAL 2013
Additional
desc-. .
Permit Fee
. . . .
263.13 Plan Check Fee
.00
Issue Date
. . . .
Valuation . .
. . 0
Expiration
Date'...
8/27/14
Qty Unit Charge
Per
Extension
1.00
23.8300
LS ELEC FIXTURES, FIRST 20
23.83
1.00
23.8300
EA ELEC SERVICES
23.83
1.00
23.8300
EA ELEC TEMP POWER POLES
23.83
1.00
143.0000
LS ELEC NEW RES, FIRST 1 KSF
143.00
4.00
-----------------------------------------
-12.1600
EA ELEC NEW RES, ADD'L 1 KSF
--------------------------
48.64
--------
Permit
. . . MECHANICAL 2013
Additional
desc .
Permit Fee
. . . .
357.54 Plan Check Fee
.00
Issue Date
. . . .
Valuation . .
. . 0
Expiration.Date
. .
8/27/14
Qty Unit Charge
Per
Extension
3.00
35.7500
EA MECH FURNACE
107.25
3.00
35.7500
EA MECH CONDENSER/COMP
107.25
11.00
11.9200
EA MECH VENT FAN
131.12
1.00
----------------------------------------------------------------------------
11.9200
EA MECH EXHAUST HOOD
11.92
LQPERMIT
'%
11
LQPERMIT
Application Number . . . . . 13-00001098
Permit . . . PLUMBING 2013
Additional desc . .
Permit Fee . . . . 464.87 Plan Check Fee
.00
Issue Date . . . . Valuation . . .
. 0
Expiration Date 8/27/14
Qty Unit Charge Per
Extension
24.00 11.9200 EA PLBG FIXTURE/TRAP
286.08
1.00 11.9200 EA PLBG BUILDING SEWER
11.92
8.00 11.9200 EA PLBG ROOF DRAIN
95.36
2.00 11.9200 EA PLBG WATER HEATER/VENT
23.84
1.00 11.9200 LS PLBG GAS SYS, 1-4 OUTLETS
11.92
1.00 35.7500 LS PLBG GAS SYS, 5+ OUTLETS
35.75
----------------------------------------------------------------------------
Special Notes and Comments
NEW SFD AT 4330 SQ. FT., PATIO 1262 SQ.
FT. AND GARAGE 946 SQ. FT.THIS PERMIT
DOES NOT INCLUDE POOL, SPA, BLOCK WALLS
OR DRIVEWAY APPROACH. BBQ, OR FIRE
PIT.HOME IS FIRE SPRINKLED PER 2010 CRC
CODES. THIS RES. WAS RELOCATED, LOT #12
ON 81-347 COLUMBUS WAY. SQ. FT. REMAINED
THE SAME. THE SAME PERMIT WAS USED
13-1098. OLD ADDRESS WAS 81-735 BAFFIN
AVE. LOT 117B.
February 28, 2014 12:23:36 PM jjohnson.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES
490.77
BLDG STDS ADMIN (SB1473)
19.00
DIF COMMUNITY CENTERS -RES
129.00
DIF CIVIC CENTER - RES
942.00
DIF FIRE PROTECTION -RES
433.00
HOURLY PLAN CHECK
572.00
DIF LIBRARIES - RES
344.00
PLAN CHECK, ELECTRICAL
119.66
DIF PARK MAINT FAC - RES
40.00
PLAN CHECK, MECHANICAL
200.22
PLAN CHECK, SFD GRADING
143.00
PLAN CHECK, PLUMBING
455.32
DIF PARKS/REC - RES
2048.00
BLDG PC 200K -1M
1462.08
STRONG MOTION (SMI) - RES
39.63
TUMF: RESIDENTIAL
1837.44
DIF STREET MAINT FAC -RES
116.00
DIF TRANSPORTATION - RES
2842.00
Fee summary Charged Paid Credited
Due
r%
Application Number . . . . . 13-00001098
Permit Fee Total 1768.17 .00 .00 1768.17
Plan Check Total .00 .00 .00 .00
Other Fee Total 12233.12 1000.00 .00 11233.12
Grand Total 14001.29 1000.00 .00 13001.29
LQPERMIT
Ccachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Andrew Young. _ (Madison Club)
Owner's Name:
Project Address: 81-347 Columbus Way, La Quinta, CA
Project Description: Addition While Under Construction
ATN: 767-690-004
Tract #:
Type of Development: Residential XX Commercial
Total Square Feet of Building Area: 408 Sq. Ft.
Date: June 12, 2014
Phone No. 760-393-5286
Lot #'s: 12B
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: & -/% -o Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project Agreement Existing Not Subject to Fee
65995 Approval Prior to 1/1/87 Requirement
408
$3.20
$1,305.60
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst Signa bre:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STAWEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires thatAtis District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/rirydocsldevfees/certificate of compliance form updated 3-2007 11/2010
.�4rA - f sp C f�utr� I� Ent i%n� eleir� %n�
77570 Springfield Lane, Suite "D" Phone: (760) 360-9998
Palm Desert, CA 92211 Fox: (760) 360-9903
STRUCTURAL OBSERVATION REPORT
FOUNDATION ONLY
May 27, 2014
City Of La Quinta
Building And Safety Department
Re.: Lot 12B
At The Madison Club
81-347 Columbus Way
La Quinta, CA.
Gentlemen,
We have performed structural observation per 2010 C.B.C. section 1710 for the
foundation condition prior to pour concrete.
Based on our visual observation and to the best of our knowledge and experience, we
believe that the foundation sizes and reinforcement that was completed at the time of our
visit, per structural plans with delta # 3 (4/25/14). These plans have not been approved by
City yet, and are undergoing plan check process. This observation has been performed per
builder request. The builder acknowledges that the plans have not approved and takes full
responsibility for any changes that might be required as per plan check comments.
Please note that this letter does not include or waive the responsibility for the City or the
Special Inspectors from determining compliance with the approved plans.
Please contact me should you need additional information regarding this approval.
Respectfully,
Reza Asgharpour, P.E. I y� r"Y'*
U) C NO.C67613
cc EXP.
Building
Address u �j
Owner
iSc�Uefu�
Mailing
Address
Ity uI CA Zip
Contractor �`�
CO kir /c
Address
u�
City Zip
State Lic.
& Classif.
014 "
P.O. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
�L"INTA, CALIFORNIA 92253
� V[ BUILDING: TYPE CONST. V� O��CPPC��. /GRP.
j J 2 A.P. Number �O� (� -1 ` o6 24
Tel. Legal Description
<N r e uvVt te�u (Zc�l��� ee
Project Description (JCS
CkftiJ
Tel.
City Sq. Ft.No. y No. Dw.
Lic. # Size Stories l Units
Arch., Engr.,
Designer sou �` A
A V�JZ� N', C C V -Lc -
Address Tel.
City Zip State
Lu ccZZS 3 Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
❑I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not appy to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. If, however, the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (5700) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person in any manner so as to become subject to Workers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
• v
Plan Chk. Bal.
Const.
Mech.
Electrical
d
Plumbing
S.M.I.
Grading
tJN Q_ bo I
Driveway Enc.
Q o
Infrastructure
TOTAL
00 ,
CONTACT INFORMATION
NAME:
PHONE:
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
YELLOW = APPLICANT PINK = FINANCE
February 21, 2014
5" Wa e0ftCop f4 --Z.
Architectural Design & Planning
78-115 Calle Estado, Suite 105
La Quinta, CA 92253
Tel (760) 564-4707
Jim Johnson
City of La Quinta Building Department
Subject; Madison Club Single Family Residence
Lot Change Lot Change to 81 347 Columbus Way
Jim
Fax (760) 564-4955
Please find the new submittals for a propose. lot change. The plans have been previously reviewed
and approved as they were submitted for lot 117 on Baffin Avenue. The plans included in this
submittal are identical to the plans submitted, reviewed and approved by the building Department.
The house plan in its entirety is being moved to lot 12 on Columbus Way, the new lot number and
address is included on the new submittals and is indicated by a Delta 2 (lot change). All drawings
documents and calculations have been updated to include the new lot number and addressing. It
has been brought to our attention that we could be looking at a code change and re -submittal if
these plans are not processed immediately.
PIE
ha)
Kin
Stephen R Nieto
if you find any items that may need our immediate attention as we would like to
proved and permitted prior to March 4.
RECEIVED
FEB 2 12014
CIiY OF QUINTA
COMMUNnY DEVELOPMENT
Building
Address
TAV/ "
Po. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
E . LA QUINTA, CALIFORNIA 92253
Mailing
Address oocl5s UL S 2
City Zip Tel.
Lam- tJtn qu,5b
& Classif. I Lic. #
Designer
Address
11�l is L
La QL11 Qta I (j ZZ�3 ILic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
01, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. If, however, the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to seff-insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
O Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person in any manner so as to become subject to Workers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONST. y OCC. GRP. IL
A.P. Number—1 %:1 --1 oU —.,(A 0
Legal Description {�
Project Description l b1 FA M I LT IGjr!��N CP
Sq. Ft. No. No. Dw. 1
Size Stories Units L
NeWX Add ❑ Alter ❑ Repair ❑ Demolition ❑
H
Estimated Valuation
",
50 10
PERMIT
AMOUNT
Plan Chk. Dep.
' O ODr
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading\
Driveway Enc.
Infrastructure
TOTAL
CONTACT INFORMATION
NAME:
PHONE:
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
YELLOW = APPLICANT
PINK = FINANCE
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
IMTIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Discovery Land Date: March 5, 2014
Owner's Name: Phone No. 760-393-5286
Project Address: 81-347 Columbus Way, La Quinta, CA 92253
Project Description:
APN: 767-690-004
Family Dwelling Unit
Tract #:
Type of Development: Residential XX! Commercial
Total Square Feet of Building Area: 4,330 SQ. Ft.
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: `/ -5- / T Signature:
************************************** *Ly *v* * * * * * * * * * * * * * * * * * * * * * * * * * * *
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PRO / HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project Agreement Existing Not Subject to Fee
65995 Approval Prior to 1/1/87 Requirement
4,330
$3.20
$13,856.00
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by. Leticia C. Torres, Facilities Analyst
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires at t s District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/myclocs!devfees/certificate ol`compliance form Updated 3-2007 11/2010
- THE -
MADISON
CLUB
OWNER'S ASSOCIATION
March 5, 2014
Mr. Scott Birdwell
East of Madison, LLC
80965 Avenue 52
La Quinta, CA 92253
RE: Lot 124 at 81347 Columbus
Final Working Drawings
Dear Mr. Birdwell:
RECt'-IVED
MAR 0 6 2014
CITY nP LA QUINTA
COMMUNFI-Y DEVELOPMENT
The Madison Club Design Review Committee (DRC) is providing an approval of your final
working drawings.
Any remaining comments relative to guideline specifications will be addressed with your builder
prior to your request for setback observation at the lot.
Please contact Brook Marshall at (760) 219-8057 or by email at DRCFacilitator@gmail.com or
Jim Brown at the Association Office with any questions.
Sincerely,
Madison Club Design Review Committee
cc:tienk-ins@discoverybuildersllc.com
DRC File
53035 MERIWETHEE WAY, LA Qvu.-v., CA 92253 TEL 760 391-4500 FAx 760 391-4599
fi II tl
a Y r� } n '"K A�ie �? c : �
a i- r,u ti a l EAS g ti.
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet,'CA. 92543 (951) 766-8777 Fax (951) 766-8778
February 27, 2014
Discovery Builders California
80-955 Avenue 52
La Quinta, California 92253
Subject: Geotechnical Update
Project: Custom Residence
Lot 12B - The Madison Club
La Quinta, California
Project No. 54414048
14-02-082
Ref: Geotechnical Investigation Report prepared by Sladden Engineering dated January
28, 2005; Project No. 544-4810, Report No. 05-01-101
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated March 2, 2006; Project No. 522-4810; Report No. 06-02-120
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence to be to be constructed on Lot 12B
within the Madison Club development in the City of La Quinta, California. It is our
understanding that the proposed residential structure will be of relatively lightweight wood -
frame construction and will be supported by conventional shallow spread footings and concrete
slabs on grade.
The subject lot was previously graded during the rough grading of the Madison Club project site.
The rough grading included recompaction of the native surface soil along with the placement of
engineered fill material to construct the building pad. The site grading is summarized in the
referenced report of Testing and Observation During Rough Grading along with the compaction
test results.
Because tlte"lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building area that falls within the previously assumed
building envelope. The building areas should be cleared of surface vegetation, scarified and
moisture conditioned prior to precise grading. The exposed surface should be compacted to a
minimum of 90 percent relative compaction prior to fill placement. The previously removed soil
and any fill material should be placed in thin lifts at near optimum moisture content and
compacted to at least 90 percent relative compaction.
February 27, 2014 -2- Project No. 544-14048
14-02-082
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. The previous reports also address the potential for liquefaction,
subsidence and differential settlement. Based upon our review of the referenced reports, it is our
opinion that the structural values included in these reports remain applicable for the design and
construction of the proposed residential structure foundations.
The allowable bearing pressures recommended in the referenced Geotechnical Investigation
report remain applicable. Conventional shallow spread footings should be bottomed into
properly compacted fill material a minimum of 12 inches below lowest adjacent grade.
Continuous footings should be at least 12 inches wide and isolated pad footings should be at least
2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
Utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.48 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pef. If used in combination with the passive resistance, the frictional resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is generally non -expansive and falls within the "very low" expansion category in
accordance with the 2013 (CSC) classification criteria. Pertinent 2013 CBC Seismic Design
parameters are summarized on the following page.
Sladden has reviewed the 2013 California Building Code (CBC) and summarized the current
seismic design parameters for the proposed structure. The seismic design category for a structure
may be determined in accordance with Section 1613 of the 2013 CBC or ASCE7. According to the
2013 CBC, Site Class D may be used to estimate design seismic loading for the proposed
structures. The 2013 CBC Seismic Design Parameters are summarized below.
Risk Category (Table 1.5-1): I/11/111
Site Class (Table 1613.3.2): D
Ss (Figure 1613.3.1):1.633g
Si (Figure 1613.3.1): 0.774g
Fa (Table 1613.3.3(1)):1.0
Fv (Table 1613.5.3(2)):1.5
Sms (Equation 16-37 (Fa X Ssl): 1.6338
Sm1(Equation 16-38 (Fv X Si)): 1.160g
SDS (Equation 16-39 (2/3 X Sms)): 1.0888
SDI (Equation 16-40 12/3 X Smll): 0.7748
Seismic Design Category: E
VI -4.4,... c....:____:....
1
February 27, 2014 -3- Project No. 544-14048
14-02-082
We appreciate the opportunity ,to provide service to you on this project, if you have any
questions regarding this letter or the referenced reports please contact the undersigned.
Respectfully submitted, +
SLADDEN ENGINEERING
FE St
QP q�
BP.ETT L.
tom` AI40ERSON
e rA5(3 m
Brett L. Anderson CD ExP .11 j4 a
Principal Engineer d cwIL
SER/gvm s��TF 0 CA
Copies: 4/ Discovery Builders California
r
LA O UIPaTA
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between'the investig ationlre porting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then. can we be assured that the construction
documents address all of the site soil conditions.
La Quinta Geotechnical Report Checklist
Does the "Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address" means:
(a) the criterion is considered significant and mitigation measure(s) noted, or;
(b) the criterion is considered insignificant and explicitly.so stated.
Yes No Criterion
® Foundation criteria based upon bearing capacity of natural or compacted soil.
® Foundation criteria to mitigate the effects of expansive soils.
® Foundation criteria based upon bearing capacity. -of natural or -comp -acted soil.
Foundation criteria to mitigate the effects of liquefaction.
® Foundation criteria. to mitigate the effacts of selsmically induced differential
settlement..
® Foundation criteria to mitigate the effects of long-term differential settlement..
; K ® Foundation criteria to mitigate the effects of varying soil strength.
C ® Foundation criteria to mitigate expected total and differential settlement.
Any "No" answers to the above checklist should be noted as specific required
corrections.
t
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9/25/2009
Green Sheet approvals are forwarded to the Buildina & Safety Department directly by Public Works. Please DO NOT
submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed
below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant.
Date: �' /��/�� Developer: Df6CQVeCW 2)01Metrs 1k)0'
Tract No.: (- Tract Name: P015* CIS Lot No.(s):
Address(s): X13`7 �°(�l(c��i((S ('✓U f (i ®UIN77t Phone Number: (r/lpD) 393'S�td'(o
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
• CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW
TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW
❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW
WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW
1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum
allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date).
If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation
Certificate can be provided.
Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils
Engineer. Recently rough graded residential developments which have a previously approved geotechnical
certification are exempt from this requirement.
nN Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan &
agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan.
PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans
& are subject to additional requirements. A current PM10 certification number is required.
Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s)
for pad elevation verification. AO flood zone developments will require an approved flood plain development plan.
6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
G7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW
approved building construction projects require either a WQMP or a completed WQMP exemption form.
Approved maps/plans may be viewed at the following link: http://www.la-auinta.org/PlanCheck/m search.aspx
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently
complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to m ipdiggs, .
the above project may be released for building permit issuance.
�'V i.
}
This section completed by City staff. � S—
l'�Z�
Recommended by: Date: / `� 0L �Q\4
Public Works Distribution: ( Green Sheet to Building & Safety
( ) Green Sheet to Planning Department ' CIIN Uj 4 �v�LpPN
Declined for approval for reason(s) as follow(s), please correct and resubmit: CCNCC�
TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
City of La Quinta - PM10 Fugitive Dust Control Project Information
Construction Phase PM10 Agreement (<1 acre/lot or Infill Project)
Project Information
Project Contractor:
Project Phase
Kn (check one)
Construction
Demolition
nn
Project Name: `.-+-�- Q CG I C P= e e
y
Project Tract/Lot Numbers: �%ni5snn CLP) l ((<}-� tAB
'r
Project Street Address: 8;- 3 Columbus waq
Total Acres in Active
Construction (<1 acre per
Lot): ,'%
1 Jr—
Anticipated Start Date: // / Anticipated Completion Date: / /vr
/
PM10 Contact
Information
Please note: Dust control is required 24 hours a day, 7 days a week, regardless of
construction status. Person listed below is responsible for dust control during business and
non -business hours.
Name:IGK
1"111
Title:
Company Name:
Q l5co u 1 OC's �. 14 r N t ck
Mailing Address:
u`'q �56 Avenue 5Z
Cit , State, ZIP Code:
Primary Phone #:
% (pQ '3C13 S Z
Fax #:
0 91 ,63
24 Hour Emergency
Phone#:
�(�f% Z-1 Q
Cell Phone #:
-7(00 Z - r q • 419g
Email Address:
(. ve • (s 10, . 6orn
PM10 Certificate #:
0v )1 ' (p q g -Z
The above stated property owner (or authorized representative):
Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD
Rules 403, 403.1, 401, 402, 201, 203 and PERP;
Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan.
Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the
period of project performance, regardless of project size or status;
•:• Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall
be in continuous compliance with all requirements of the approved dust control plan;
s• Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust
control plan are necessary;
s Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes;
Shall hol rmless the City/County and its representatives from liability for any actions related to this dust control
plan any ' /County initiated
abatement activities.
ignature of Property Owner or Authorized Representative Date
TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
City of La Quinta - PM10 Fugitive Dust Control Plan (<1 acre per Lot or Infill Project)
This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201,
203 and Portable Equipment Registration Program (PERP).
WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily.
Water shall be applied from an adequate sized metered water source to dry soils to prevent:
■ Visible dust emissions >20% opacity
■ Visible dust emissions that travel >100 feet from the source (within site)
■ Visible dust emissions that cross any property line
• EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class and
obtain PM10 certificate number prior to construction activity (training information may be obtained by contacting
SCAQMD at (909) 396-2183).
CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be kept
on site. At least one short-term stabilization method must be used during off hours. At least one long-term
stabilization measure must be used within ten (10) days of ceasing activity.
•: WEATHER MONITORING: Wind predictions shall be monitored.
•3 SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella Valley
Fugitive Dust Control Plan Handbook for Construction Signage Guidelines.
�o TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate
on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of
15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on
pad.
ee PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only.
TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works
inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident and at
the conclusion of each workday.
S• DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading
requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or
grading permit.
FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be
installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace
PM10 fencing during the construction phase.
i• EQUIPMENT: Extra hoses and sprinklers shall be maintained on site.
:• EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be
applied during excavation or grading operations.
DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving site.
:• INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required.
s• RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records of use of chemical
suppressants, etc.) shall be maintained for 3 years by the Property Owner (or Authorized Representative).
Property Owner shall notify the City and SCAQMD within 10 days of completion of project.
TAChecklists - Forms 8 ApplicationslFonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
WEDDLE
SURVEYING MAPPING, INC.
Boundary • Construction • Topographic •Aerial Surveys •ALTA Surveys • GPS • Consulting
June 2, 2014
Mr. Timothy R. Jonasson
Public Works Director / City Engineer
City of La Quinta
78-495 Calle Tampico
La Quinta, CA 92253-1504 .
Re: Pad/Form Grade Verification
City of La Quinta
DOUBLE BOGEY, -LLC RESIDENCE
Lot 12B
Lot 12 Tract No. 33076-2 MB 393/61-80
81-369 Columbus Way, La Quinta, CA
MADISON CLUB
APN 767-690-004
Dear Mr. Jonasson:
We have performed a field survey to determine the vertical location of the Building Pad and
Building Form for the above referenced project. The elevations observed are as follows:
PAD (DESIGN)
1001.0'
FORM (DESIGN)
1001.50'
PAD (AS -BUILT)
1000.9'
FORM (AS -BUILT)
1001.59'
These field observations are in substantial conformance with the Precise Grading Plan prepared
by ESSI ENGINEERING, dated 2/21/14, approved by the City of La Quinta Building & Safety
Department and the building horizontal location substantially conforms to the required setbacks
and site layout as shown on the approved site plan.
Sincerely,
WED E SURVEYING MAPPING, INC.
David L. Weddle, President
L.S. 5570, exp 09/30/15
P:O. Box 10418 • Palm Desert, CA 92255-0418
77-725 Enfield Lane, Ste. 140 • Palm Desert, CA 92211 • 760.360.5570
E -Mail: wedsury@aol.com • Fox 760.360.5573
EsGil Corporation
In (Partnership with Government for Buifding Safety
DATE: MAR. 15, 2013
JURISDICTION: LA QUINTA
PLAN CHECK NO.: 12-1476
PROJECT ADDRESS: 81-347 COLUMBUS WAY
SET: II
❑,DcPPLICANT
,0 JURIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAME: SFR FOR DISCOVERY LAND BUILDERS/DBCA
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
® The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
® EsGil Corporation staff did not advise the applicant that the plan check has been completed.
❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
Fax #:
71 REMARKS: On window schedule, Sheet A8.05, note tempered glass for windows J & M within
60" of stairs & landing. Section R308.4.
By: ALI SADRE Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ PC 3/14
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576