11-0483 (SOL)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
11-00000483- --
Property Address:
51915 AVENIDA CORTEZ
APN:
773 -152 -021 -
Application description:
SOLAR
Property Zoning:
COVE RESIDENTIAL
Application valuation:
28700
T`ht 4 4 Q"
Applicant: Architect or Engineer:
a1�
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Licens Class: C46 License No.: 661434
ate: - IC? - l( ontractor:
OWNER- UILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code)or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I—) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
CINQ MARS CAROLYN
51915 AVENIDA CORTEZ
LA QUINTA, CA 92253
Contractor:
MOHR POWER SOLAR, INC.
1452 POMONA ROAD
CORONA, CA 92882
(951)736-7000
Lic. No.: 661434
----------------------------
WORKER'S COMPENSATION
VOICE (760) 777-7012
FAX (760) 717-7011
INSPECTIONS (760) 777-7153
Date: 8/19/11
D
20`1 L1
NTA
DECLARfkTtO
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier COMMERCE AND IN Policy Number WC003788118
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to beco a subject to the workers' compensation laws of California,
and agree that, if I should become bjea to the the compensation provisions of Section
rrQ 370ff0 of the bor Code, I el with comply with those provisions.
ate: \ / �1 pplicant:
WARNING: FAILURE TO SECURE WORKEF6 COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS (5100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction__& hereby authorize representatives
of this cc `to enterC on the above-mentioned property for inspe ' n p ses.
/ q `Si ature (Applicant or Agent):
Application Number . . . . . 11-00000483
Permit ELEC-MISCELLANEOUS
Additional desc . .
Permit Fee . . . . 22.50 Plan Check Fee
5.63
Issue Date . . . . Valuation . . .
. 0
Expiration Date . . 2/15/12
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 7.5000 EA ELEC PWR APP >1 TO <=10
----------------------------------------------------------------------------
7.50
Permit SOLAR PERMIT
Additional desc .
Permit Fee . . . . 25.50 Plan Check Fee
6.38
Issue Date . . . . Valuation .
. 28700
Expiration Date . . 2/15/12
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 4.5000 EA SOLAR COLLECTOR < 1000
4.50
.2.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS
6.00
--------------------------------------------------7-------------------------
Special Notes and Comments
6.3kW SOLAR ARRAY - (34) 180W SCHUCO
PANELS W/ (2). KACO (6000W TOTAL)
INVERTERS [480SF] 2010 CALIFORNIA
ELECTRICAL CODE.
August 1, 2011 2:52:05 PM AORTEGA
---------------------------------
------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
Permit Fee Fee Total 48.00 .00 .00
48.00
Plan Check Total 12.01 .00 .00
12.01
Other Fee Total 2.00 .00 .00
2.00
Grand Total 62.01 .00 .00
62.01
LQPERMIT
AJ Orteaa
From: AJ Ortega
Sent: Monday, July 11, 201110:35 AM .
To: 'afathi@sungevity.com'
Subject: 51-915 Avenida Cortez - Remaining Corrections
Attachments: 51-915 Avenida Cortez.pdf
Ali Fathi,
Please clarify the attached redlined comments from sheet PV4.1 — The conductor sizes shown on sheet PV2.1 comply
with Table 310.16 and 310.15(B)(2)(c), yet the conductors calculated in wiring schedule do not comply. Additionally for
roof top conduits the ambient temperature correction factors in Table 310.16 are required to be increased based on .
clearance from roof as shown in Table 310.15(B)(2)(c). Please provide revised PV4.1 sheet by email for approval.
AJ Ortega, Building Inspector II
City of La Quinta I Building & Safety Department
Direct 760.777.7018 1 Fax 760.777.7011
a o rteg a (a. l a -o u i n t a .oro
City of La Quinta
78-495 Calle Tampicol La Quinta, CAI 92253
www.la-guinta.org
1
sunGEVITY'
SOLAR HOME SPECIALISTS
LA QUINTA Corrections
Homeowners Address: 51-915 AVENIDA CORTEZ
Permit Number: 11-0483
Plan checker:
Plan checker contact: 760-777-7012
Correctors/Designer name: ALI FATHI
Correctors/Designer contact: afathi@sungevitv.com, 408-300-1315
Responses:
1. ,Conduit from junction box to inverter will be roof mounted then run down side of house to
inverter(s).
.2. Added APN number to plans.,
3. Showing GEC being spliced prior to being run in one conduit; if option is chosen by
installer.
4. Changed from 50A load center breaker to 40A load center, breaker.
5. Clarifying Equipment to Equipment calculations.
.AJ Ortega
From: Ali Fathi <afathi@sungevity.com>
Sent: Thursday, July 28, 20112:11 PM
To: AJ Ortega
Subject: Re: FW: 51-915 Avenida Cortez - Remaining Corrections
Attachments: CINQ-MARS_29091_PLAN S.pdf
Hello AJ Ortega,
Here are the corrections for 51915 Avenida Cortez project. Please review and let me know if there are any other
fixes needed.
Thank you in advance,
Ali Fathi
On Fri, Jul 22, 2011 at 1:52 PM, AJ Ortega <Aortega@la-guinta.org> wrote:
From: AJ Ortega
Sent: Monday, July 11, 2011 10:35 AM
To: 'afathi@sungevitv.com'
Subject: 51-915 Avenida Cortez - Remaining Corrections
Ali Fathi,
Please clarify the attached redlined comments from sheet PV4.1 — The conductor sizes shown on sheet PV2.1 comply with Table
310.16 and 310.15(B)(2)(c), yet the conductors calculated in wiring schedule do not comply. Additionally for roof top conduits the
ambient temperature correction factors in Table 310.16 are required to be increased based on clearance from roof as shown in Table
310.15(B)(2)(c). Please provide revised PV4.1 sheet by email for approval.
AJ Ortega, Building Inspector II
City of La Quinta I Building & Safety Department
Direct 760.777.70181 Fax 760.777.7011
ao rtega(tb,l a -g u i nta. o rg
City of La Quinta
78495 Calle Tampico) La Quinta, CAI 92253
www.la-quinta.org
ALI FATHI I DESIGN AND ENGINEERING I Sungevity Solar Home Specialists
66 Franklin Street, Oakland, CA'j 408-300-1315 office'l 650-492-0669 cell I afathi@sungevity.com
Have you gotten your Quote yet? http://www.sungevity.com
Bin #
Qty of La Quinta
Building 8z Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # a3
Project Address: 5 t A V t;14 l ao, 2 — _
Owner's Name: (_\(Z O L ` r t/k yc\ L
A. P. Number: 7-7 0 2
Address: �
Legal Description:
City, ST, Zip: L�
Contractor:
/R\4�ry 5 iJ{:. `:Mv:%F.hi Ytibti..\H
Tele hone:- SCF (� ' SU 9
Address: ILII- L (L r'j-
Project Description:
City, ST, Zip: CO 2 o n 1in
Telephone: �G' ZU
;
j k ,..1
State Lic. # : L o (P I City Lic. #;
Arch., Eng/r._, Designer: SJi / t 7
y 1
Address:, (� - cLyarJ \L L JJ 5 I
ILA&af'
City, ST, Zip: O A, tL L o j,6 "I 1J.U70-7
Telephone: 5 ( O - I I C / ' S STS
State Lic. #:
;ez ..s :w�^nk,; s: :::.,
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: --�F�
Sq. Ft.:
# Stories:
#Units:
Telephone # of Contact Person: SI - S 32 -23`1
Estimated Value of Project: 7-%
APPLICANT: DO NOT WRITE BELOW THIS LINE
q
Submittal
Req'd
Rec'd
G `% PERMIT FEES
Plan Sets
Plan Check submitted Item Amount
Structural Calcs.
Reviewed, ready for correettiWY 1 0 211Plan Check Deposit
Truss Calcs.
Called Contact Person Plan Check Balance r+
Title 24 Cities.
Plans picked up �Y?"`t �• (,y v Construction LS b�
Flood plain plan
Plans resubmitted
Mechanical ..+
Grading plan
2°' Review, ready for ect' s/issue 1
a Electrical
Subcontactor List
Called Contact Person 1 1 L,�
Plumbing
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted t Grading ^
IN HOUSE:-
'nd Review, ready for correction ssu 1911 Developer Impact Fee
Planning Approval
Called Contact Person .I.P.P..
Pub. Wks. Appr
Date of permit issue
School Fees
otal Permit Fees AL
����4`'LMt ' Qt�'�� Er�M.'. IMti�- [al�t��-+ �LCrt 1µ�+s�-od 1.�'1${�u-- �.aa•�.��
dol'W►t `l�0► A4k*4 - Lei' 1aQm"v••` ,1 — Ofv
' sola - Q� •�
Twif 4 4Q"
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR)
DATE: MAY 19, 201 V
STATUS: FIRST REVIEW
PLAN CHECKED BY: AJ ORTEG,* �i
TELEPHONE NUMBER: (760) 777-7018
(760) 777-70 12
FAX (760) 777-7011
ADDRESS: 51-915 AVENIDA CORTEZ
DESCRIPTION: PV SOLAR SYSTEM
APPLICANT: MOHR POWER SOLAR
PLAN CHECK #: 11-0483
This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:
1- SOLAR (REDLINED) PLAN
2- UNMARKED PLAN SET
1- CORRECTION LIST
4AL44 U
BUILDING DEPARTMENT STAFF:
DO NOT accept any resubmittal unless ALL of the
following items are included:
1- SOLAR (REDLINED) PLAN
1- CORRECTION LIST w/responses
2- REVISED PLAN SETS
1- ASSESSORS SITE/FLOOR PLAN
{
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal. "
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List (SOLAR) Page 1 of 3
SECTION A - GENERAL
Provide a Sheet Index, Vicinity Map (with north arrow covering at least a two -block area), Assessor's Parcel
Number (APN) and a Complete Legal Description on the first sheet of Plans.
Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code'5536. Resubmittals will not be accepted with signatures missing.
Note on Plans: "All construction shall comply with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes and the La Q0inta Municipal Code."
SECTION B — SOLAR
I. General
Reconcile noted information shown on single line diagram. See 1" review redlined plan. Please provide a
response for each item, either on returned redlined plan or in letter.
II. Circuit Requirements
/' No corrections apply.
III. Disconnecting Means
I) No corrections apply.
IV. Wiring Methods
� ••�. gip. -.
1� All PV system wiring must be made using otie o'fth, specific-.instollation/materials methods included in the
2010 California Electrical Code. (CEC §69[}.31, Chapter 3) Run lbcations not specified on roof plan or in
single line diagram, please show locations on site plain or specify on single line diagram.
Where the number of current -carrying conductors in a raceway exceed three (3) the allowable ampacity of
each conductor shall be reduced as shown in Table 310.15(B)(2)(a). (CEC §310.15(B)(2)) See PV4.1 sheet.
ondu its exposed to sunlight on rooftops, where conductors or cables are installed, the adjustments shown in
Table 310.15(B)(2)(c) shall be added to the outdoor temperature to determine the applicable ambient
temperature for application of the correction factors in Table 310.16. (CEC §310.15(B)(2)(c)) Adjust
conductor sizes according to the proposed conduit locations.
V. Grounding
�No corrections apply.
VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts
The output of a utility -interactive inverter shall be permitted to be connected to the load side of the service
disconnecting means of the other source at any distribution equipment on premises. Where such a connection
is made, the interconnection provisions of CEC Section 690.64(B)(1) through (13)(7) shall apply. Calculation
for 120% of bus rating shown, but breaker specified on single line diagram exceeds allowable.
Residential Plan Check Correction List (SOLAR) Page 2 of 3
City of La Quinta
SECTION C - STRUCTURAL
1) No corrections apply.
SECTION D - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each of the, Site Plan and Floor Plan for the County Assessor's office: While not required
for resubmittal, this administrative item must be addressed prior to issuance of building permit.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 3 of 3
51915 Cortez (Avenida)