10-0166 (RER)cz��. — ..
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 10-00000166
Property Address: 78197 CRIMSON CT
APN: 604-024-040- - -
Application description: REMODEL - RESIDENTIAL
Property Zoning: MEDIUM DENSITY RES
Application valuation: 2200
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
AREND RANDALL T
78197 CRIMSON CT
LA QUINTA, CA 92253
_ Contractor:
Applicant: Architect or Engineer: OLD SCHOOL INSTALLATI
9781 LUTHERAN WAY
SANTEE, CA 92071
(619) 448-6610
Lic. No.: 896973
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in I force and effect.
nse Class: C6 'cense No.: 8 973
Dater ah&>Contractor:
OWNER -BUIL DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.). ,
Lender's Name: _
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 3/05/10
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE BOARD Policy Number 467-0011690
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should beco s bject to the workers' compen tion provisions of Section
�{ 3700 of the Labor Co I fort ith comply with those pr 'ions.
ate: +—���Applican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL'FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to co ply with all
city and ounty ordinances and state Taws relating to buildin tru i n, nd hereby out rize re entatives
t 1
oft caun to enter upon the above-mentioned prepe or ins tion p �s
ate: '--Signature (Applicant or Agent): '�
Application Number . . . . . 10-00000166
Permit BUILDING PERMIT
Additional desc .
Permit Fee . . . . 54.00
Plan Check
Fee
35.10
Issue Date . . . .
Valuation
. . .
. 2200
Expiration Date 9/01/10
Qty Unit Charge Per
Extension
BASE FEE
45.00
1.00 9.0000 THOU BLDG 2,001-25,000
9.00
----------------------------------------------------------------------------
Special Notes and Comments
REMOVE AND REPLACE SIX WINDOWS AND ONE
SLIDING GLASS DOOR PER PLAN. NO CHANGE
IN SIZES FROM ORIGINAL. 2007 CBC. gb
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE
3.51
Fee summary, Charged Paid
---------------------------
Credited
Due
----------
Permit Fee Total 54.00
----------
.00
----------
.00
54.00
Plan Check Total 35.10
.00
.00
35.10
Other Fee Total 3.51
.00
.00
3.51
Grand Total 92.61
.00
.00
92.61
LQPERMIT
Bin #
City of La Quints
Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
p
Project Address: _ n� G�
Owner's Name: �V
A. P. Number:
Address: 73—t17-7 C o �S Com'
Legal Description:
City, ST, Zip: LA C-4. Z S>,
Contractor:�"
�3
`.:lX
r t'Telehone: %// µ ;
Address: /►L�Q�.! (,✓
Project Description: ._1C'T _
City, ST, Zip: .TIt-
CEJ
Telephone: j
>z•c's.a;:>.;<rsif is
State Lic. # : City Lic. #;
Arch., Engr., Designer: — —
Address:
City, ST, Zip:
Telephone:
ep
3: ,>=::;> .::: : > s•
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
State Lic. #:
Name of Contact Person:
Sq. Ft:
#Stories: %
# Units:
Telephone # of Contact Person:
Estimated Value of Project: $' 4,=, e d
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submittedaj
Item
Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cates.
Called Contact Person
Pian Check Balance
Title 24 Calcs.
Pians picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2nd Review, ready for corrections/issue
Electrical
Subeontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub, Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
Certificate of
Residential Alterations
Project Name: n
lance: Residential
CF -IR -ALT
(Page 1 of 5)
Climate Zone k k of Stories
General Information
Site Address: -I8I ct c . Enforcement Agency: Date:
Building Type ❑ Single Family 10 Multi Family Circle the Front Orientation: N, EOW, or degrees
Conditioned Floor Area (CFA): Project Type: ❑ Alterations ❑ Envelope ❑ Fenestration ❑ Roof ❑ HVAC
Replacement or Change Out ❑ Duct Replacement ❑ Water Heater
NOTE: This form is not to be used for NewlyConstructed Buildings or Additions
insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below)
Assembly Alteration
❑ Opening of framed cavity alone - Alterations that irrvolve the opening of the framed cavity of a wall, ceiling, or floor must install the
mandatory minimum insulation value per §1 S0 for the altered assembly. Fill in Columns A -C and enter mandatory insulation value in Column H.
❑ Replacement of entire assembly - Replacement of an entire wall, ceiling, or floor assembly requires the installation of Component
Package- D insulation values in Table 151-C. Fill in Columns A - J.
Opaque Surface Details For the furred egrtioned of Mass Walls see Furring Strips Construction Table below.
A B C D E F G H II J
Proposed See 0(0 Standard Values From JA4 Table
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
Framing
Thickness, Framed Continuous JA4 Proposed
Taq
ID
Assembly Name
or Type'
Material
and Size2
Spacing, U- JA4 Table Cavity insulation Assembly Assembl
or Other' factor` Numbers R -value° R -Value' Cell Values U -factor
i$c
Assembly
j
w
c `o ° t= o m �a > Final
° °
Mass
Name or
JA4 Table
b =, A Assembly
'
Thickness'
Type'
Number'
Q >
Note: For furred assemblies, accounting for Comimeous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and
Furrin Construction table below.
1. For Tagf l) indicate the identification name that matches the building plans.
2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc... Indicate the Frame type and Size: For
Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies.
3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC: or Other for all other assembly description
such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel and etc....
4. Based on the Climate Zone: enter the Standard U factor from Table 151-B, C or D for each different assembly Name or type.
S. Enter the Table number that closely resembles the proposed assembly.
6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0 ".
7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter 1101..
8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J
9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply.
Furring Strips Construction Table for Mass Walls Onl
A B I C I D I E
F G I H 1 J 1 K L M
Proposed Properties of Masonry and Concrete
Added Interior or Exterior Insulation
Walls From Reference
in Furring Space from Reference
Joint Appendix Table 4.3.5, 4.3.6 4.3.7
Joint Appendix Table 4.3.13
A
i$c
Assembly
j
w
c `o ° t= o m �a > Final
° °
Mass
Name or
JA4 Table
b =, A Assembly
'
Thickness'
Type'
Number'
Q >
e X 2U. 'U. a > Ir U -factor Comment
Registration Number: Registration Date;Time:
2008 Residential Compliance Forms
HERS Provider:
August 2009
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations age 2 of 5
Project Name:p Climate Zone # # of Stories
FL,A !i Lai f Dlc�
and Furrine Strips Construction
1. Indicate the type of assembly to include: Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can
befound Reference Joint Appendix JA4.
2. This is the U -Factor based on the thickness of the assembly in inches.
3. The R -value of the insulation to be added on the interior or exterior of the assembly.
4. The Calculated R- Value is the R -value of the furred out section of the assembly.
-6. The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix JA4. The equation is the inverse of Column
added to Column I. Column K is the inverse from column J.
7. Insert the calculated U- actor value on to the Opaque Surface Details in Column J
FENESTRATION PROPOSED AREAS
Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in
Table 151-C The Total Fenestration and West facing Area requirements are not applicable.
❑ Adding 50ft2 or less of window area — Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component
Package D in Table 151-C.
❑ Adding more than 50ft' of window area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration
Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -IR -ALT
Orientation
E
F G
Fenestration Type and Frame (North, East. PropsedAreal
Maximum
Maximum
NFRC or Default
Window Glass Door or Skylight)South, West(ft')
U-factorz' j
SHGC'' 1.4
Values
nr.,0O-,_7 t1fo
Fenestration
Area
Fenestration
G/V O k-
a
Dwelling
CFA
S r -
Removed
Area Added
A x B) (E -D) + C
/`Jo 2i
2
0
2
0. Mo
LJ ,
d
/
iN/��
Z
�•
�
e
77
/. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration
area may be the glass area plus a "2 inch frame " around the glass.
2. Enter value from Component Package D Requirements in Table 151-C.
3. Actual fenestration products installed and as indicated in CF -6R -ENV Form shall be equivalent to or have a lower U factor and/or a lower
SHGC value than that specified on the CF -1 R ALT Form.
4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading.
5.trapplicable at this stage enter "NERC" or NERC Certified windows or are CEC -Default " values ound in Table 116-A or B.
ALTERED FENESTRATION ALLOWED AREAS (Complete if more than 50ftt
o fenestration
is added)
A
B
C
D
E
F G
Allowed
Existing
Fenestration
Total Area
CFA of Entire
% of
Fenestration
Area
Fenestration
Allowed Proposed Area
Dwelling
CFA
Area
Removed
Area Added
A x B) (E -D) + C
Total Fenestration Area
20
>
West Fenestration Area
(Required In
.05
>
CZ's 2, 4 & 7 -15)
i. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12.
2. West facing glazing area removed cannot be "counted" twice. " /n order to distribute the west glazing area removed to the other orientations,
input the west glazing area removed in the Total Fenestration Area row, column D.
3. Include the Proposed Area of the West facing fenestration in both Area columns below.
4. To meet compliance. the Proposed Area must be less than orequal to the Tota! Allowed Area or BOTH the Total and West Fenestration Areas.
Registration A`umber: Registration Date%Time: _ HERS Provider:
2008 Residential Compliance Forms August 2009
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 5 of 5
Project Name:,o Cli ste Zone # # of Stories
Alf .1F
HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this
checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final
inspection.
Duct Sealing & Testing HERS verification is required for this measure.
❑ YES E3 NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned
space, the ducts are to be sealed per §152(b)IDii and the newly installed ducts are to be insulated per §151(f)10.
❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos.
❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the
ducts are to be sealed per § l52(b)IDi.
❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler,
outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be
sealed per § 152(b) I E.
❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reference Residential Appendix RA3.
E3 EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space.
❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos.
Refrigerant Charge -Split System HERS verification is required for this measure.
❑ YES 13 NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air
handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat
exchanger) a refrigerant charge measurement shall be verified per § 152(b)IF.
Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw
The ventilation requirements of § I 50(o) do not apply to existing residential homes.
Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required for this measure.
YES 13 NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is
replaced, the airflow and fan watt draw shall be verified per § 152 b 1Ci to meet the requirements of § 151(f)7B.
Documentation Author's Declaration Statement
• I certify that this Certificate of Compliance documentation is accurate and complete.
Name:
Signa
! �:4
Company:
Date:
c r !tZ
Address:
LU
If Applicable ❑ CEA or ❑ CEPE
-7-
(Certification #):
City/State/Zip:^Awrr q;70Phone:
(O
Responsible Building Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on
this Certificate of Compliance.
• 1 certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform
to the requirements of Title 24, Parts l and 6 of the California Code of Regulations.
• The building design features identified on this Certificate of Compliance are consistent with the information provided to document this
building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
Name:
Signature:
Company:
Date:
Address:
License:
City/State/Zip:
Phone:
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
Registration Number:
2008 Residential Compliance Forms
Registration Date/Time: HERS Provider:
August 2009
3
DIN
CUSTOMER: RANDY AREND
i
KIT
'I
I
OFFICE
4
6
FAM
LIV
MST BR
1
walkway
NOT TO SCALE
SILL HEIGHT
FROM FINISHED
FLOOR:
1) 36"
2) 36..
3) 23„
4) 2302
7
6) 23"
6) 36"-
7) Patio Door
WINDOW
CALL -OUT SIZE:
1)
3AX410X-OWIN
2)
SAX410X-0 WIN
3)
5A X SIO X -O WIN
4)
1!6 X SIO S.HUHG WIN
S)
1!6 X!5/0 S.HUHG WIN
6)
Sl6.X SIO X -O WIN
7)
610 X 618 O -X TEMP PAT
DR