05-3174 (AR)P.O. BOX 1504
\ 78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Ti"It4'1400111a
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: /05-00003174,/
Property Address: 79045 COYOTE CREEK
APN: 772-030-025-31 -25429 -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 100000
Applicant: Architect or Engineer:
Owner:
GWEN VANCE
79-045 COYOTE CREEK
LA QUINTA, CA 92253
4 Contractor:
PAGE CONSTRUCTION
WCC: COMBINED
01/ WC: 46-0039720101
CSLB: 716999
6�QOC LiC. No.: NO
----------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: License No.: NO
ate: Contract .
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contrac'tor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereo nd who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State Lice s Law.).
(_ 1 I am exempt under Sec. •, B.&P. or this reason
Date: I I " /(n - 0S_ Owner:
CONSTRUCTION LENDING AGENCY -
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
` Lender's Name: _
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 11/16/05
06/01/06
06/30/06
-- -- -------------------------------------------—
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as iequired by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier B Policy Number 200
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so a become subject to the workers' compensation laws of California,
and agree that, if 1 shoul b -me subject to the workers' compensation provisions of Section
3700 of the Labor Code, hall forthwith ply w' h those provisions.
Ddfe: ' ��� Applicant/
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the abov i ormation is correct. I agree to comply with all
city and county ordinances and state laws relating to building o ruction, and hereby authorize representatives
Of this co ty to enter upon the above-mentioned propAyrspection purpo
Date/-At/'/i0� Signature (Applicant or Agent):
Application Number . . . . . 05-00003174
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
639.50
Plan Check
Fee
415.68
Issue Date
Valuation
. . . .
100000
Expiration Date
5/09/06
Qty Unit Charge
Per
Extension
BASE
FEE
414.50
50.00 4.5000
----------------------------------------------------------------------------
THOU BLDG
50,001-100,000
225.00
Permit . . .
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . .
26.55
Plan Check
Fee'.
6.64
Issue Date
Valuation
. . . .
0
Expiration Date
5/09/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
330.00 .0350
----------------------------------------------------------------------------
ELEC
NEW RES - 1 OR 2
FAMILY
11.55
Permit
MECHANICAL
Additional desc . .
Permit Fee . . . .
30.50
Plan Check
Fee
7.63
Issue Date
Valuation
. . . .
0
Expiration Date .
5/09/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00 9.0000
EA MECH
APPL REP/ALT/ADD
9.00
1.00 6.5000
------------------------------------------------------------
EA MECH
EXHAUST HOOD
---------------
6.50
Permit . . .
PLUMBING
Additional desc .
Permit Fee
30.00
Plan Check
Fee
6.75
Issue Date . . . .
Valuation
. . . .
0
Expiration Date
5/09/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2.00- 6.0000
EA PLB
FIXTURE
12.00
1.00 3.0000
EA PLB
GAS PIPE 1-4 OUTLETS
3.00
-------------------------------------------------------
Special Notes and Comments
.---------------------
interior.renovation.
patio conversion
LQPERMIT 11
•Application Number . . . . .
05-00003174
---------------------•-------------------------------------------------------
Special Notes and Comments
to living space.November,10,
2005
6:37:50 AM jjohnson
----------------------------------------------------------------------------
Other Fees .. . . . . . . .
ENERGY REVIEW
FEE
41.57
STRONG MOTION
(SMI) - RES
10.00
Fee summary Charged
Paid Credited
--------------------
Due
---------------------------
Permit Fee Total 726.55
----------
.00
.00
726.55 '
Plan Check Total 436.70
.00
.00
436.70
Other Fee Total 51.57
.00
.00
51.57
Grand Total 1214.82
.00
.00
1214.82
LQ
Bin #
City of. La Quinta
Building 81DivisionSafety
Box 1504; 78-495 Calle Tampico
La Quinta, CA 92253.- (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #P.O.
2 -74
10, l
Project Address: 7, r, e 7
Owner's Name: 7
A. P. Number:
Address:
Legal Description:
City, ST, Zip:
Contractor:hi J94 15-eQl/STle_a TION
Telephone:
Address: '7�7 k-16 . dI%(t,t/7)gj,4)'1/1eZ l
Project Description S-�rv(✓ Jrw GV►C.n
City, ST, Zip: LrN �� L�P.rZ i �// 9Lz I
-�v r ✓l w a . S t'GG C < ,-, ,, i n -
Telephone: Q.�v+_z
e% rK arv� e-FrannG ?C�•�rr
State Lic. # :
City Lic. #:
5 cvt d E c7 • t'�ro (ti c ti At d e wa-
Arch., Engr., Designer:
S d
Address:
jL�
��� e. 4 � �� r � )X,4rvNL .
City, ST, Zip:
Telephone:
State Lic. #:
d r. kGT Fd r S l-ZG mit
Construction Type: Occupancy:
Project type (circle one): New Add'ri. Alter Repair Demo
Sq. Ft.: # Stories: # Units:
Name of Contact Person: (�/1v
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACMG . PERMIT FEES
?j
Plan Sets
Plau.Check submitted
1 Item Amount
Structural Cales.
Reviewed; ready for corrections
Plan'Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Energy Cales.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading. plan
2" Review, ready for correctio issue
Electrical
Subcontactor List
Called Contact Person �' (11 QIKL
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue IT,
10
School Fees
Total Permit Fees
31 ab S-/W%4r F<> 32owL .i C) & - 5 a,A
r f i , . i<A /Q Af I
TITLE 24 REPORT
i.
Title 24 Report for:
Vance Residence
79-045 Coyote Creek
La Quinta, CA
06P 51#14
ITY OF LA QUINTA
VILDING
Project Designer:,
&SAFETY DEPT.
APPROVEDFOR
[DA
CONSTR CTION
B
Report Prepared By:
Joan D. Hacker
Insu-Form Inc.
68255 Corta Road
Cathedral City, CA 92234
(760) 324-0216
Job Number:
r= Date:
r., 9/15/2005 ,
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Checklist g
Form C -2R Computer Method Summary g
HVAC System Heating and Cooling Loads Summary 15
Room Load Summary 16
`,._certificate of Compliance: 'Residential (Part 1 of 2) CF -1 R
Vance Residence 9/15/2005
rroject Title Date
79-045 Coyote Creek La Quinta
Project Address Building Permit #
Insu-Form Inc. (760) 324-0216 plan Check /Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 4,025 ft2 Average Ceiling Height: 10.0 ft
Total Conditioned Slab Area: 4,025 ft2
Building Type:
n/a
(check one or more)
Covered Slab w/R-0.0 Perimeter Insulation
Single Family Detached
❑ Addition
❑ Single Family Attached
❑ Existing Building
❑ Multi -Family
FRI Existing Plus Addition
Front Orientation: (North)
0 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
1 ❑ Raised Floor
Component
Const.
Frame Assembly Location/Comments
Type U -Value (attic, garage, typical, etc.)
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
R-19 Wall (W.19.2x6.16)
Wood
0.065
Exterior Wall
R-19 Roof (R.19.2x8.16)
Wood
.0-051
Exterior Roof
Default Wall 1978-1991
Wood
0.098
Exterior Wall
Solid Wood Door'
None
0.387
Exterior Door
Default Roof 1978 to Present
Wood
0.047
Exterior Roof
rcNr_a I KH I IUN
vnaun
arcv wca
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes /
No
Yes / No
Rear
(South)
487.0
0.85
0.70
Bug Screen
X❑
❑
❑ Q
Right
(West)
96.0
0.85
0.70
Bug Screen
x❑
❑
❑ x❑
Front
(North)
43.0
0.87
0.70
Bug Screen
x❑
❑
❑
Left
(East)
53.4
0.85
0.70
Bug Screen
❑
❑ Q
Left
(East)
15.0
0.72
0.73
Bug Screen
X❑
❑
❑ x❑
Left
(East)
44.0
0.87
0.70
Bug Screen
x❑
❑
❑ x❑
Right
(West)
52.0
0.87
0.70
Bug ScreenX❑
❑
❑ Q
Right
(West)
9.0
0.72
0.73
Bug Screen
x❑
❑
❑x❑
❑
❑
❑ ❑
❑❑
El
El
F1
El
❑
❑
❑ ❑
Run Initiation Time: 09/15/05 11:40:52 Run Code: 1126809652
Ener Pro 3.1 By Ener Soft
User Number: 2655
Job Number:
Pa e:3 of 16
_'Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Vance Residence 9/15/2005
project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
r;Pntral Furnas 78%AFUE Ducts in Attic 2.1 Setback Living Zone
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
heat pump, evap. cooling) (SEER) (attic, etc.
Duct Thermostat Location /
R -Value Type Comments
Split Air Conditioner 9.0 SEER Ducts in Attic 21 Setback I iving 7nne
WATER HEATING SYSTEMS
Rated 1 Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
Standard Gas 50 gal or Leq Small Gas Standard 2_ 40,000 50 0.53 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
I.VIVIII'LIANGt J I A I trAt:N I
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
>•F31-1 M_
Title/Firm:
Address: Design Concepts
57445 29 Palms Hwy. St. 304 M
Telephone: Yucca valley, ca 92284
Lic. #:
-I:L_� -t-(L=- 4 -15 -as -
(signature) (date)
Enforcement Agency
- Name:
Title/Firm:
Address:
-Telephone:
Name: Joan D. Hacker
Title/Firm: Insu-Form Inc.
Address: 68255 Corta Road
Cathedral City, CA 92234
Telephone: (760) 324-0216
(sign tur (date)
ature/stam
IEnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:4 of 16 1
CP,irtificate of Compliance: Residential (Addendum) CF -1 R
Vance Residence 9/15/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
o..`y.... Y aPa� aluau#wduon dnu uucurnentauon suomineo. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
1-- 1-1 IRIUQ. UV�UIIIVIIL use „r,u venncatuon ano oiagnostic testing of tnese measures on a torm ct--b R.
Plan
Field
`0
Run Initiation Time: 09/15/05 11:40:52 Run Code: 1126809652
nergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:5 of 16
-Mandatory Measures Checklist: Residential (Page 1 of 2)MFA R
1
11 NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER I ENFORCEMENT
Building Envelope Measures
'§150(a): Minimum R-19 ceiling insulation.
❑ §150(b): Loose fill insulation manufacturer's labeled R -Value.
a1150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
❑ `§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
a§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
F§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§1_50(i): Setback thermostat on all applicable heating and/or cooling systems.
❑ §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 16
a. -
Mandatory Measures Checklist: Residential (Page 2 of 2) . MF -1 R
}NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
X] I150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3: ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181S. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
j
heating, and no pilot.
i
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
i
§118 (f): Cool Roof material meet specified criteria
El I
Lighting Measures
F] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
El§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
j
3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 16
Computer Method Summary (Part 1 of 3) C -2R
Vance Residence 9/15/2005
Prpject Title Date
Z9=-045Gn ote Cr ek I a_Qllinta
-Project Address 'Building Permit #
Insu-Form In . (760) 324-0216
Documentation Author Telephone Plan Check/Date
CI
Field Check/Date
Source Energy Use
(kBtu/sf-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Existing+Addition Budget Adjustment
Single Fam Detached
Space Heating 2.89
Space Cooling 32.44
Domestic Hot Water 7.08
Totals 67.83+ 42.41 = 110.24
Percent better than Standard:
4.13
96.18
9.18
-1.24
-63.74
-2.10
Ratio F: 3695 / 4025 = 0.918
Budget Adj: 0.918 X (120.65- 46.76) = 67.83
The budget shown to the left has been increased using
this Budget Adjustment based upon Existing building
information shown on the C -2R which follows this form.
109.49
0.75
0.7%
Total Conditioned Floor Area:
4,025 ft2
Floor Construction Type: ❑
Raised Floor X❑ Slab Floor
Building Type:
Single Fam Detached
Building Front Orientation:
(North) 0 deg
Total Fenestration Area:
19.9%
Number of Dwelling Units:
1.00
Total Conditioned Volume:
40,250 ft'
Number of Stories:
1
Total Conditioned Slab Area:
4,025 ft 2
BUILDING ZONE INFORMATION
Zone Name
Floor Area Volume
402 40 750
# of Thermostat Vent
Units Zone Type Type Hgt. Area
1 Op_ Conditioned gpthark _2 n/a
Living 7nne
Solar
OPAQUE SURFACES
Act. Gains
Type Area U -Fac. Azm. Tilt Y / N
Wall 117 _0_065 180 go
Wall 95 1098 180 �Q
Wall _295 __QM8_ __2M _94
Roof. 3,695 0 047 _0 _0.
EnerovPro 3.1
Form 3 Reference
R-19 Wall (W 19.2x6.16)
R-19 Wall ON is x i 16)
R-19 Roof (R 19.2x8 16)
Default Wall 1978-1991
,i�l Wood Do9r
Default Wall 1478-1441
Default Wall 1978-199.1
Default Wall 1978_1891
Default Roof 1478 to PreCent
User Number: 2655 Job Number:
Location / Comments
Additinn
Additinn
Additinn
Living 7nne
Living 7nne
Lig 7nnp
Living 7nne
L iving 7nne
liuiIIg 7nnp
8of16
Computer Method Summary (Part 2 of 3) C -2R
Vance Residence 9/15/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
u-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
1_
Window Rear
(South)
_ a8 o
0850
070
180
qO Double Mtl Uncoated Default
Addition
2
Window Rear
(South)
295.0
0.850
0.70
180
90 Double Mtl Uncoated Default
Addition
3
Window Right
(West)
32.0
0.850
0.70
270
90 Double Mtl Uncoated Default
Addition
4
Window Front
(North)
16.0
0.870
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
5
Window Front
(North)
8.0
0.870
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
6
Window Front
(North)
7.0
0.870
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
Z
Window Front
(North)
12.0
0,870
0.70
_ 0
90 Double Mtl Uncoated Default
Living
Zone
8
Window Left
(East)
53.4
0.850
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
9
.Window Left
(East)
15.0
0,720
0.73
90
90 Double Mtl Uncoated Default
Living
Zone
10
Window Left
(Eases
8.0
0,870
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
"
Window Left
(East)
36.0
0.870
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
12
Window Rear
(South)
40.0
0.850
0.70
180
90 Double Mtl Uncoated Default
Living
Zone
13
Window Rear
(South)
64.0
_0,850
__O_7Q
180
90 D_Quble Mtl Uncoa1ed_Q_efault
ljvina
Zone
14
Window Right
(West)
64.0
0.850
0.70
270
90 Double Mtl Uncoated Default
Living
Zone
15
Window Right
(West)
36.0
0.870
0.70
270
90 Double Mtl Uncoated Default
Living
Zone
16
Window Right
(West)
9.0
0.720
0.73
270
90 Double Mtl Uncoated Default
Living
Zone
17
Window Right
(West)
16.0
0.870
0.70
270
90 Double Mtl Uncoated Default
Living
Zone
INTERIOR AND EXTERIOR SHADING
#
Window
Overhang Left Fin
Right Fin
_
Exterior Shade Type
SHGC
Hgt.
Wd.
Len Hgt
LEA. RExt Dist Len
Hgt
Dist Len Hgt
1
Bug Screen
0.76
8.0
11.0
2.0
0.1
2.0 2.0
2
Bug Screen
0.76
10.0
25.5
2.0
0.1
2.0 2.0
_
3
Bug Screen
0.76
8.0
4.0
2.0
0.1
2.0 2.0
4
Bug Screen
0.76
4.0
4.0
2.0
0.1
2.0 2.0
5
Bug Screen
0.76
4.0
2.0
2.0
0.1
2.0 2.0
_
6
Bug Screen
0.76
2.5
3.0
2.0
0.1
2.0 2.0
7
Bug Screen
0.76
2.0
6.0
2.0
0.1
2.0 2.0
8
Bug Screen
0.76
6.8
8.0
2.0
0.1
2.0 2.0
9
Bug Screen
0.76
1.5
10.0
2.0
0.1
Ro 2.0
10
Bug Screen
0.76
4.0
2.0
2.0
0.1
2.0 2.0
Ti
Bug Screen
0.76
6.0
6.0
2.0
0.1
2.0 2.0
12
Bug Screen
0.76
6.8
6A
2.0
0.1
2.0 2.0
13
Bug Screen
0.76
8.0
8.0
2.0
0.1
2.02.0
14
Bug Screen
0.76
8.0
8.0
2.0
0.1
2.0 2.0
15
Bug Screen0.76
6.0
3.0
2.0
0.1
2.0 2.0
16
Bug Screen
0.76
1.5
6.0
2.0
0.1
2.0 2.0
17
Bug Screen
0.76
4.0
4.0
2.0
0.1
2.0 2.0
_
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Pacie:9 of 16 1
Computer Method Summary (Part 3 of 3) C -2R
Vance Residence 9/15/2005
Project Title Date _
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in,.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 16 0.76 0.0 0 Addition
,9jab3erimster 305 0.766, ALO. 0 Livina Zone
HVAC SYSTEMS
Heating Equipment
Minimum-
Distribution Type
Type (furnace, heat .
Efficiency
and Location
Duct
Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic, etc.)
R -Value
Type
Comments
Centr'al Furnace
76%AFUE
Ducts in Attic -
2.1
Setback
Living Zone
Pipe Pipe
Hydronic Piping
Insul.
System Name
Length Diameter
Thick.
Cooling Equipment.
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct
Thermostat
Location /
heat pump, evap. cooling) (SEER)
(attic, etc,)
R -Value
Type
Comments
Split Air Conditioner
9.0 SEE
Ducts in Attic
--2-1
Setback
Livina Zone
WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value
System Name Type Type Svst. (Btu/hr) (aal) Efficiencv Loss M) Ext.
Standard Gas 50 gal or Less Small Gas Standard 2 40.000 50 0.53 n/a 12
1 For small gas storage (rated input <= 75000 Btu/hr),.electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. .
RE
EnergyPro- 3.1 By EnergySoft User Number: 2655 Job Number: Paae:10 of 16 i
Gamputer Method Summary (Addendum) C -2R
Vance Residence 9/15/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may.reject a building or design that otherwise complies
vdacu un uie dueyudcy UI LIM speuial jusimcadon and documentation suDmittea. Plan Field
The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket.
HERS Required Verification
These features must be confirmed and/or tested byy a certified HERS rater under the supervision of a CEC approved HERS
r�.,.�..�I. he I II -IRS, rale, IIIu�. uucumern the need vermcation and diagnostic testing of these measures on a form QF-sR. plan Field
EnergyPro 3.1 By EnergySoft User Number: 2655' Job Number: Page: 11 of 16 1
.Cmputer Method Summary
(Part 1 of 3) C -2R
Vance Residence
.911512005
Project Title
Date
79-045Q,ovote('rPtzk I a-Quinta
Project Address
Building Permit #
Ins -Farm Inc-
(760) 324-0216
Documentation Author
Telephone
Plan check/Date
C�-mputer-P - ormanc�
15
Field Check/Date
compliance Method (Package or Computer)
Climate Zone
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 3.66
5.45
-1.79
Space Cooling 35.38
105.19
-69.81
Domestic Hot Water 7.71
10.00
-2.29
Totals 46.76
120.65
-73.89
Percent better than Stand
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION
Zone Name
3,695 ft Floor Construction Type: ❑ Raised Floor ❑X Slab Floor.
Single Fam Detached
(North) 0 deg Total Fenestration Area: 20.4%
1.00 Total Conditioned Volume: 36,950 ft 3
1 Total Conditioned Slab Area: 3,695 ft 2
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
# of
Thermostat Vent
Floor Area Volume Units Zone Tvoe TvDe Hat. Area
Wall- 709 0.098 0_ 90
nnnr 48 0 387 0 go
Wall 424 o n.98 qn A0
WaN 520 ---Q-098 _1-80- gQ
Wall 222- 0 098 _2255 ---K
Wall 425 . 0 ng$ 270 gn
Rnnf 3'.695 Q047 Q _ Q
Solar
Gains
Y / N Form 3 Reference
�.
A.
lmzl R -M-15; ma* svyxlrsluz�p MM -1
❑❑
❑❑
❑❑
❑❑
7
F1 F1
❑
°❑
❑ ❑:. .
❑❑
E] ED
2 n/a
Location / Comments
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:12 of 16 1
Computer
Method Summary
(Part 2 of 3) C 2R
Vance Residence
9/15/2005
Project
Title
Date
.FENESTRATION SURFACES
#
Type
U-
Act..
Glazing Type
Location/
Area
Factor
SHGC
Azm.
Tilt
Comments
J--
2
_Window
Front
(North)
16 0
8.0
0 870
0.870
_0 7n
0.70
0
0
q0 Double Mtl uncoated Default
I iving_7one
3
Window
Front
(North)
7.0
90 Double Mtl Uncoated Default
Livinq
Zone
4
Window
Front
(North)
12.0
0.870
0.870
0.70
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
5
Window
Left
(East)
53.4
0.850
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
6
Window
Left
(East)
90
90 Double Mtl Uncoated Default
Living
Zone
Z
Window
Left
15.0
0.720
0.73
90
90 Double Mtl Uncoated Default
Living
Zone
8
Window
Left
(East)
(East)
8.0
64.0
0.870
0.850
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
0.70
90
90 Double Mtl.Uncoated Default
Living
Zone
5
W ndow
Left
( ast
36 0
0.870
p 70
_ 0
90 Double M Uncoated Default
Living
Zone
10
Window
Rear
---(South)
30.0
0.870
0.70
180
90 Double Mtl Uncoated Default
Living
Zone
1
12
Window
Window
Rear
Rear
(South)
38.0
0.720
0.73
180
90 Double Mtl Uncoated Default
Living
Zone
(South)
160.0
0.850
0.70
180
90 Double Mtl Uncoated Default
Living
Zone
13
14
Wadow
Window
Rear
Rear
�Snirthl
(Southwest)
_�
128.0
0.870
0.850
_270
0.70
180
225
_�0 Q9ubJe-M1LUmcoated Default
90 Double Mtl Uncoated Default
I iv�
Living
Zone
15
Window
Right
(West)
64.0
0.850
0.70
270
90 Double Mtl Uncoated Default
Zone
16
Window
Right
(West
36.0
0.870
0.70
270
90 Double Mtl Uncoated Default
_Living
Zone
17
Window
Right
(West)
9.0
0.720
0.73
270
90 Double Mtl Uncoated Default
_Living
Living
Zone
18
Window
Right
(West)
16.0
0.870
0.70
270
90 Double Mill Uncoated Default
Living
Zone
INTERIOR AND EXTERIOR SHADING
# Gv4e rir.r Ck-.t.. -r..--
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
SHGC
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
M=9
Hgt. Wd.
4:0 4.0
4.0 2.0
2.5 3.0
2.0 6.0
6.8 8.0
1.5 10.0
4.0 2.0
8.0 8.0
6.0 6.0
6.0 5.0
6.4 3.0
10.0 16.0
5.0 3.5
8.0 8.0
8.0 8.0
6.0 3.0
1.5 6.0
4.0 4.0
Len.
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0 1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
0.1 2.0
Z.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
Left Fin Right Fin
Dist. Len. Hgt. Dist. Len.
I EnergyPro 3.1 By EnergySoft User Number 2655 Job Number. Paae:13 of 16
Computer Method Summary (Part 3 of 3) C -2R
Vance Residence - 9/15/2005
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
PERIMETER LOSSES
F2 Insulation
Type Length, Factor R -Val. Depth Location / Comments
_Slab Perimeter 380 0.76 0 0 0 Living Zone
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct
Thermostat.
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic,
etc.)
R -Value
Type
Comments
Central Furnace
781 AFUE
Qucts in Attic
2.1
Setback
Living Zone
Hydronic Piping Pipe
Pipe
Insul,
System Name Length
Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,.
Efficiency
Location
Duct
Thermostat
Location /
heEft pump, evap. cooling)
(SEER).
(attic, etc,)
R -Value
Type
Comments
Split Air Conditioner
9.0 SEER
Ducts in Attic
2.1
Setback
Living Zone
i
WATER HEATING SYSTEMS Rated Tank Energy Facts 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap., or Recovery Standby R -Value
System Name Type Type Syst (Btu/hr) - (gal) Efficiency Loss M Ext.
Standard Gas 50 gal or Less Small Gas Standard 2 40,000 50 0.53 n/a 12
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
Itor instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
R
H.�fAC SYSTEM HEATING AND COOLING LOADS SUMMARY
RROJECT NAME
DATE
Vance Residence
9/15/2005
SYSTEM NAME
Living Zone
FLOOR AREA
4,025
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems j 3
COIL COOLING PEAK COIL HTG. PEAK
Heating System
CFM Sensible Latent CFM I Sensible
Output per System 71,000
Total Room Loads 4,387 92,354 8,936 1,969 89,296
Total Output(Btuh)
Return Vented Lighting 0
Output (Btuh/sgft) 52.9
52..9
Return Air Ducts 4,618 4,465
Cooling System
Return Fan o 0
Output per System I 48,000
Ventilation 0 0 0 0 0
Total Output (Btuh) 144,000
Supply Fan oI 0
Total Output (Tons) 12.0
Supply Air Ducts 4,618 4,465
Total Output (Btuh/sgft) 35.8
Total Output (sgft/Ton) 335.4
TOTAL SYSTEM LOAD 101,58 8 9361 98225
Air System
HVAC EQUIPMENT SELECTION
CFM per System 1,500
Airflow (cfm) I 4,500
Exist 103,960 22,918 213,000
Airflow (cfm/sgft) 1.12
I
Airflow (cfm/Ton) 375.0
Outside Air (%) I 0.0
Total Adjusted System Output 103,960 22,918 213,000
(Adjusted for Peak Design Conditions)
Outside Air (cfm/sgft) I 0.00
TIME OF SYSTEM PEAK Aug 2pm I Jan 12 ami
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26.0 OF 69.1 OF 69.1 OF
113.6 OF
Outside Air
-aw,
Supply Air Ducts
0 cfm
Supply Fan Heating Coil 112.6 of
4500 cfm
r�
pOOMc
`�77
69.1 of
70.0 of
Return Air Ducts I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.9/77.6OF 79.0/64.4OF 79.0/64.5OF 57.2/56.1OF
&Outside Air
Supply Air Ducts
0 cfm §
Supply Fan
Cooling Coil 58.2 / 56.4 of
4500 cfm
`
-
47.2% R.H. ROOMS
79.0/64.4 of
78.0 / 64.1 of
Return Air Ducts
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 15 of 16
ROOM LOAD SUMMARY
Cl.l IVAMt
Vance Residence
:M NAME
Living Zone
DATE '
9/15/2005
FLOOR AREA
'4 m
ROOM LOAD SUMMARY
ZONE NAME
Addition
Living Zone
ROOM NAME
Addition
Existing Living
Mult.
1
1
ROOM
CFM
975
3,412
COOLING
SENSIBLE
20,527
71,827
PEAK COIL
LATENT CF M
153 975
8,783 3,412
COOLING
SENSIBLEI
20,527
71,827
PEAK
LATENT
153
8,783
COIL
CFM
389
1,580
HTG. PEAK
SENSIBLE
17,653
71,642
PAGE TOTAL 14,387 92,3548,936 1,969 89,296
Y
TOTAL 4,387 92,354 8,9361,969 89,296
EnergyPro 3.1 By EnergySoft User Number 2655. Job Number Page 16 of 16