Loading...
05-3174 (AR)P.O. BOX 1504 \ 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Ti"It4'1400111a BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: /05-00003174,/ Property Address: 79045 COYOTE CREEK APN: 772-030-025-31 -25429 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 100000 Applicant: Architect or Engineer: Owner: GWEN VANCE 79-045 COYOTE CREEK LA QUINTA, CA 92253 4 Contractor: PAGE CONSTRUCTION WCC: COMBINED 01/ WC: 46-0039720101 CSLB: 716999 6�QOC LiC. No.: NO ---------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: NO ate: Contract . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contrac'tor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1—) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereo nd who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State Lice s Law.). (_ 1 I am exempt under Sec. •, B.&P. or this reason Date: I I " /(n - 0S_ Owner: CONSTRUCTION LENDING AGENCY - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). ` Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/16/05 06/01/06 06/30/06 -- -- -------------------------------------------— WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as iequired by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier B Policy Number 200 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a become subject to the workers' compensation laws of California, and agree that, if 1 shoul b -me subject to the workers' compensation provisions of Section 3700 of the Labor Code, hall forthwith ply w' h those provisions. Ddfe: ' ��� Applicant/ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abov i ormation is correct. I agree to comply with all city and county ordinances and state laws relating to building o ruction, and hereby authorize representatives Of this co ty to enter upon the above-mentioned propAyrspection purpo Date/-At/'/i0� Signature (Applicant or Agent): Application Number . . . . . 05-00003174 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 639.50 Plan Check Fee 415.68 Issue Date Valuation . . . . 100000 Expiration Date 5/09/06 Qty Unit Charge Per Extension BASE FEE 414.50 50.00 4.5000 ---------------------------------------------------------------------------- THOU BLDG 50,001-100,000 225.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . 26.55 Plan Check Fee'. 6.64 Issue Date Valuation . . . . 0 Expiration Date 5/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 330.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 11.55 Permit MECHANICAL Additional desc . . Permit Fee . . . . 30.50 Plan Check Fee 7.63 Issue Date Valuation . . . . 0 Expiration Date . 5/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 6.5000 ------------------------------------------------------------ EA MECH EXHAUST HOOD --------------- 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 30.00 Plan Check Fee 6.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00- 6.0000 EA PLB FIXTURE 12.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ------------------------------------------------------- Special Notes and Comments .--------------------- interior.renovation. patio conversion LQPERMIT 11 •Application Number . . . . . 05-00003174 ---------------------•------------------------------------------------------- Special Notes and Comments to living space.November,10, 2005 6:37:50 AM jjohnson ---------------------------------------------------------------------------- Other Fees .. . . . . . . . ENERGY REVIEW FEE 41.57 STRONG MOTION (SMI) - RES 10.00 Fee summary Charged Paid Credited -------------------- Due --------------------------- Permit Fee Total 726.55 ---------- .00 .00 726.55 ' Plan Check Total 436.70 .00 .00 436.70 Other Fee Total 51.57 .00 .00 51.57 Grand Total 1214.82 .00 .00 1214.82 LQ Bin # City of. La Quinta Building 81DivisionSafety Box 1504; 78-495 Calle Tampico La Quinta, CA 92253.- (760) 777-7012 Building Permit Application and Tracking Sheet Permit #P.O. 2 -74 10, l Project Address: 7, r, e 7 Owner's Name: 7 A. P. Number: Address: Legal Description: City, ST, Zip: Contractor:hi J94 15-eQl/STle_a TION Telephone: Address: '7�7 k-16 . dI%(t,t/7)gj,4)'1/1eZ l Project Description S-�rv(✓ Jrw GV►C.n City, ST, Zip: LrN �� L�P.rZ i �// 9Lz I -�v r ✓l w a . S t'GG C < ,-, ,, i n - Telephone: Q.�v+_z e% rK arv� e-FrannG ?C�•�rr State Lic. # : City Lic. #: 5 cvt d E c7 • t'�ro (ti c ti At d e wa- Arch., Engr., Designer: S d Address: jL� ��� e. 4 � �� r � )X,4rvNL . City, ST, Zip: Telephone: State Lic. #: d r. kGT Fd r S l-ZG mit Construction Type: Occupancy: Project type (circle one): New Add'ri. Alter Repair Demo Sq. Ft.: # Stories: # Units: Name of Contact Person: (�/1v Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACMG . PERMIT FEES ?j Plan Sets Plau.Check submitted 1 Item Amount Structural Cales. Reviewed; ready for corrections Plan'Check Deposit Truss Cales. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading. plan 2" Review, ready for correctio issue Electrical Subcontactor List Called Contact Person �' (11 QIKL Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue IT, 10 School Fees Total Permit Fees 31 ab S-/W%4r F<> 32owL .i C) & - 5 a,A r f i , . i<A /Q Af I TITLE 24 REPORT i. Title 24 Report for: Vance Residence 79-045 Coyote Creek La Quinta, CA 06P 51#14 ITY OF LA QUINTA VILDING Project Designer:, &SAFETY DEPT. APPROVEDFOR [DA CONSTR CTION B Report Prepared By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: r= Date: r., 9/15/2005 , The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist g Form C -2R Computer Method Summary g HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 16 `,._certificate of Compliance: 'Residential (Part 1 of 2) CF -1 R Vance Residence 9/15/2005 rroject Title Date 79-045 Coyote Creek La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 plan Check /Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,025 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 4,025 ft2 Building Type: n/a (check one or more) Covered Slab w/R-0.0 Perimeter Insulation Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family FRI Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-19 Wall (W.19.2x6.16) Wood 0.065 Exterior Wall R-19 Roof (R.19.2x8.16) Wood .0-051 Exterior Roof Default Wall 1978-1991 Wood 0.098 Exterior Wall Solid Wood Door' None 0.387 Exterior Door Default Roof 1978 to Present Wood 0.047 Exterior Roof rcNr_a I KH I IUN vnaun arcv wca Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (South) 487.0 0.85 0.70 Bug Screen X❑ ❑ ❑ Q Right (West) 96.0 0.85 0.70 Bug Screen x❑ ❑ ❑ x❑ Front (North) 43.0 0.87 0.70 Bug Screen x❑ ❑ ❑ Left (East) 53.4 0.85 0.70 Bug Screen ❑ ❑ Q Left (East) 15.0 0.72 0.73 Bug Screen X❑ ❑ ❑ x❑ Left (East) 44.0 0.87 0.70 Bug Screen x❑ ❑ ❑ x❑ Right (West) 52.0 0.87 0.70 Bug ScreenX❑ ❑ ❑ Q Right (West) 9.0 0.72 0.73 Bug Screen x❑ ❑ ❑x❑ ❑ ❑ ❑ ❑ ❑❑ El El F1 El ❑ ❑ ❑ ❑ Run Initiation Time: 09/15/05 11:40:52 Run Code: 1126809652 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 16 _'Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Vance Residence 9/15/2005 project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments r;Pntral Furnas 78%AFUE Ducts in Attic 2.1 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc. Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 9.0 SEER Ducts in Attic 21 Setback I iving 7nne WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Leq Small Gas Standard 2_ 40,000 50 0.53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. I.VIVIII'LIANGt J I A I trAt:N I This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author >•F31-1 M_ Title/Firm: Address: Design Concepts 57445 29 Palms Hwy. St. 304 M Telephone: Yucca valley, ca 92284 Lic. #: -I:L_� -t-(L=- 4 -15 -as - (signature) (date) Enforcement Agency - Name: Title/Firm: Address: -Telephone: Name: Joan D. Hacker Title/Firm: Insu-Form Inc. Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: (760) 324-0216 (sign tur (date) ature/stam IEnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:4 of 16 1 CP,irtificate of Compliance: Residential (Addendum) CF -1 R Vance Residence 9/15/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies o..`y.... Y aPa� aluau#wduon dnu uucurnentauon suomineo. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS 1-- 1-1 IRIUQ. UV�UIIIVIIL use „r,u venncatuon ano oiagnostic testing of tnese measures on a torm ct--b R. Plan Field `0 Run Initiation Time: 09/15/05 11:40:52 Run Code: 1126809652 nergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:5 of 16 -Mandatory Measures Checklist: Residential (Page 1 of 2)MFA R 1 11 NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER I ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. a1150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ `§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. F§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §1_50(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 16 a. - Mandatory Measures Checklist: Residential (Page 2 of 2) . MF -1 R }NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3: ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181S. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance j heating, and no pilot. i 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) i §118 (f): Cool Roof material meet specified criteria El I Lighting Measures F] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. El§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. j 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 16 Computer Method Summary (Part 1 of 3) C -2R Vance Residence 9/15/2005 Prpject Title Date Z9=-045Gn ote Cr ek I a_Qllinta -Project Address 'Building Permit # Insu-Form In . (760) 324-0216 Documentation Author Telephone Plan Check/Date CI Field Check/Date Source Energy Use (kBtu/sf-yr) Standard Design Proposed Design Compliance Margin Existing+Addition Budget Adjustment Single Fam Detached Space Heating 2.89 Space Cooling 32.44 Domestic Hot Water 7.08 Totals 67.83+ 42.41 = 110.24 Percent better than Standard: 4.13 96.18 9.18 -1.24 -63.74 -2.10 Ratio F: 3695 / 4025 = 0.918 Budget Adj: 0.918 X (120.65- 46.76) = 67.83 The budget shown to the left has been increased using this Budget Adjustment based upon Existing building information shown on the C -2R which follows this form. 109.49 0.75 0.7% Total Conditioned Floor Area: 4,025 ft2 Floor Construction Type: ❑ Raised Floor X❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 19.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 40,250 ft' Number of Stories: 1 Total Conditioned Slab Area: 4,025 ft 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume 402 40 750 # of Thermostat Vent Units Zone Type Type Hgt. Area 1 Op_ Conditioned gpthark _2 n/a Living 7nne Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Wall 117 _0_065 180 go Wall 95 1098 180 �Q Wall _295 __QM8_ __2M _94 Roof. 3,695 0 047 _0 _0. EnerovPro 3.1 Form 3 Reference R-19 Wall (W 19.2x6.16) R-19 Wall ON is x i 16) R-19 Roof (R 19.2x8 16) Default Wall 1978-1991 ,i�l Wood Do9r Default Wall 1478-1441 Default Wall 1978-199.1 Default Wall 1978_1891 Default Roof 1478 to PreCent User Number: 2655 Job Number: Location / Comments Additinn Additinn Additinn Living 7nne Living 7nne Lig 7nnp Living 7nne L iving 7nne liuiIIg 7nnp 8of16 Computer Method Summary (Part 2 of 3) C -2R Vance Residence 9/15/2005 Project Title Date FENESTRATION SURFACES # Type Area u- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1_ Window Rear (South) _ a8 o 0850 070 180 qO Double Mtl Uncoated Default Addition 2 Window Rear (South) 295.0 0.850 0.70 180 90 Double Mtl Uncoated Default Addition 3 Window Right (West) 32.0 0.850 0.70 270 90 Double Mtl Uncoated Default Addition 4 Window Front (North) 16.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 5 Window Front (North) 8.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 6 Window Front (North) 7.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone Z Window Front (North) 12.0 0,870 0.70 _ 0 90 Double Mtl Uncoated Default Living Zone 8 Window Left (East) 53.4 0.850 0.70 90 90 Double Mtl Uncoated Default Living Zone 9 .Window Left (East) 15.0 0,720 0.73 90 90 Double Mtl Uncoated Default Living Zone 10 Window Left (Eases 8.0 0,870 0.70 90 90 Double Mtl Uncoated Default Living Zone " Window Left (East) 36.0 0.870 0.70 90 90 Double Mtl Uncoated Default Living Zone 12 Window Rear (South) 40.0 0.850 0.70 180 90 Double Mtl Uncoated Default Living Zone 13 Window Rear (South) 64.0 _0,850 __O_7Q 180 90 D_Quble Mtl Uncoa1ed_Q_efault ljvina Zone 14 Window Right (West) 64.0 0.850 0.70 270 90 Double Mtl Uncoated Default Living Zone 15 Window Right (West) 36.0 0.870 0.70 270 90 Double Mtl Uncoated Default Living Zone 16 Window Right (West) 9.0 0.720 0.73 270 90 Double Mtl Uncoated Default Living Zone 17 Window Right (West) 16.0 0.870 0.70 270 90 Double Mtl Uncoated Default Living Zone INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin _ Exterior Shade Type SHGC Hgt. Wd. Len Hgt LEA. RExt Dist Len Hgt Dist Len Hgt 1 Bug Screen 0.76 8.0 11.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 10.0 25.5 2.0 0.1 2.0 2.0 _ 3 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 _ 6 Bug Screen 0.76 2.5 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 2.0 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.5 10.0 2.0 0.1 Ro 2.0 10 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 Ti Bug Screen 0.76 6.0 6.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.8 6A 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.02.0 14 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 15 Bug Screen0.76 6.0 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 1.5 6.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 _ EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Pacie:9 of 16 1 Computer Method Summary (Part 3 of 3) C -2R Vance Residence 9/15/2005 Project Title Date _ THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in,.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 16 0.76 0.0 0 Addition ,9jab3erimster 305 0.766, ALO. 0 Livina Zone HVAC SYSTEMS Heating Equipment Minimum- Distribution Type Type (furnace, heat . Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Centr'al Furnace 76%AFUE Ducts in Attic - 2.1 Setback Living Zone Pipe Pipe Hydronic Piping Insul. System Name Length Diameter Thick. Cooling Equipment. Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 9.0 SEE Ducts in Attic --2-1 Setback Livina Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Svst. (Btu/hr) (aal) Efficiencv Loss M) Ext. Standard Gas 50 gal or Less Small Gas Standard 2 40.000 50 0.53 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr),.electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. . RE EnergyPro- 3.1 By EnergySoft User Number: 2655 Job Number: Paae:10 of 16 i Gamputer Method Summary (Addendum) C -2R Vance Residence 9/15/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may.reject a building or design that otherwise complies vdacu un uie dueyudcy UI LIM speuial jusimcadon and documentation suDmittea. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested byy a certified HERS rater under the supervision of a CEC approved HERS r�.,.�..�I. he I II -IRS, rale, IIIu�. uucumern the need vermcation and diagnostic testing of these measures on a form QF-sR. plan Field EnergyPro 3.1 By EnergySoft User Number: 2655' Job Number: Page: 11 of 16 1 .Cmputer Method Summary (Part 1 of 3) C -2R Vance Residence .911512005 Project Title Date 79-045Q,ovote('rPtzk I a-Quinta Project Address Building Permit # Ins -Farm Inc- (760) 324-0216 Documentation Author Telephone Plan check/Date C�-mputer-P - ormanc� 15 Field Check/Date compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.66 5.45 -1.79 Space Cooling 35.38 105.19 -69.81 Domestic Hot Water 7.71 10.00 -2.29 Totals 46.76 120.65 -73.89 Percent better than Stand Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 3,695 ft Floor Construction Type: ❑ Raised Floor ❑X Slab Floor. Single Fam Detached (North) 0 deg Total Fenestration Area: 20.4% 1.00 Total Conditioned Volume: 36,950 ft 3 1 Total Conditioned Slab Area: 3,695 ft 2 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt # of Thermostat Vent Floor Area Volume Units Zone Tvoe TvDe Hat. Area Wall- 709 0.098 0_ 90 nnnr 48 0 387 0 go Wall 424 o n.98 qn A0 WaN 520 ---Q-098 _1-80- gQ Wall 222- 0 098 _2255 ---K Wall 425 . 0 ng$ 270 gn Rnnf 3'.695 Q047 Q _ Q Solar Gains Y / N Form 3 Reference �. A. lmzl R -M-15; ma* svyxlrsluz�p MM -1 ❑❑ ❑❑ ❑❑ ❑❑ 7 F1 F1 ❑ °❑ ❑ ❑:. . ❑❑ E] ED 2 n/a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:12 of 16 1 Computer Method Summary (Part 2 of 3) C 2R Vance Residence 9/15/2005 Project Title Date .FENESTRATION SURFACES # Type U- Act.. Glazing Type Location/ Area Factor SHGC Azm. Tilt Comments J-- 2 _Window Front (North) 16 0 8.0 0 870 0.870 _0 7n 0.70 0 0 q0 Double Mtl uncoated Default I iving_7one 3 Window Front (North) 7.0 90 Double Mtl Uncoated Default Livinq Zone 4 Window Front (North) 12.0 0.870 0.870 0.70 0.70 0 90 Double Mtl Uncoated Default Living Zone 5 Window Left (East) 53.4 0.850 0.70 0 90 Double Mtl Uncoated Default Living Zone 6 Window Left (East) 90 90 Double Mtl Uncoated Default Living Zone Z Window Left 15.0 0.720 0.73 90 90 Double Mtl Uncoated Default Living Zone 8 Window Left (East) (East) 8.0 64.0 0.870 0.850 0.70 90 90 Double Mtl Uncoated Default Living Zone 0.70 90 90 Double Mtl.Uncoated Default Living Zone 5 W ndow Left ( ast 36 0 0.870 p 70 _ 0 90 Double M Uncoated Default Living Zone 10 Window Rear ---(South) 30.0 0.870 0.70 180 90 Double Mtl Uncoated Default Living Zone 1 12 Window Window Rear Rear (South) 38.0 0.720 0.73 180 90 Double Mtl Uncoated Default Living Zone (South) 160.0 0.850 0.70 180 90 Double Mtl Uncoated Default Living Zone 13 14 Wadow Window Rear Rear �Snirthl (Southwest) _� 128.0 0.870 0.850 _270 0.70 180 225 _�0 Q9ubJe-M1LUmcoated Default 90 Double Mtl Uncoated Default I iv� Living Zone 15 Window Right (West) 64.0 0.850 0.70 270 90 Double Mtl Uncoated Default Zone 16 Window Right (West 36.0 0.870 0.70 270 90 Double Mtl Uncoated Default _Living Zone 17 Window Right (West) 9.0 0.720 0.73 270 90 Double Mtl Uncoated Default _Living Living Zone 18 Window Right (West) 16.0 0.870 0.70 270 90 Double Mill Uncoated Default Living Zone INTERIOR AND EXTERIOR SHADING # Gv4e rir.r Ck-.t.. -r..-- 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen SHGC 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 M=9 Hgt. Wd. 4:0 4.0 4.0 2.0 2.5 3.0 2.0 6.0 6.8 8.0 1.5 10.0 4.0 2.0 8.0 8.0 6.0 6.0 6.0 5.0 6.4 3.0 10.0 16.0 5.0 3.5 8.0 8.0 8.0 8.0 6.0 3.0 1.5 6.0 4.0 4.0 Len. 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0 1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 0.1 2.0 Z.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. I EnergyPro 3.1 By EnergySoft User Number 2655 Job Number. Paae:13 of 16 Computer Method Summary (Part 3 of 3) C -2R Vance Residence - 9/15/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length, Factor R -Val. Depth Location / Comments _Slab Perimeter 380 0.76 0 0 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat. Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 781 AFUE Qucts in Attic 2.1 Setback Living Zone Hydronic Piping Pipe Pipe Insul, System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner,. Efficiency Location Duct Thermostat Location / heEft pump, evap. cooling) (SEER). (attic, etc,) R -Value Type Comments Split Air Conditioner 9.0 SEER Ducts in Attic 2.1 Setback Living Zone i WATER HEATING SYSTEMS Rated Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap., or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) - (gal) Efficiency Loss M Ext. Standard Gas 50 gal or Less Small Gas Standard 2 40,000 50 0.53 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. Itor instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. R H.�fAC SYSTEM HEATING AND COOLING LOADS SUMMARY RROJECT NAME DATE Vance Residence 9/15/2005 SYSTEM NAME Living Zone FLOOR AREA 4,025 ENGINEERING CHECKS SYSTEM LOAD Number of Systems j 3 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM I Sensible Output per System 71,000 Total Room Loads 4,387 92,354 8,936 1,969 89,296 Total Output(Btuh) Return Vented Lighting 0 Output (Btuh/sgft) 52.9 52..9 Return Air Ducts 4,618 4,465 Cooling System Return Fan o 0 Output per System I 48,000 Ventilation 0 0 0 0 0 Total Output (Btuh) 144,000 Supply Fan oI 0 Total Output (Tons) 12.0 Supply Air Ducts 4,618 4,465 Total Output (Btuh/sgft) 35.8 Total Output (sgft/Ton) 335.4 TOTAL SYSTEM LOAD 101,58 8 9361 98225 Air System HVAC EQUIPMENT SELECTION CFM per System 1,500 Airflow (cfm) I 4,500 Exist 103,960 22,918 213,000 Airflow (cfm/sgft) 1.12 I Airflow (cfm/Ton) 375.0 Outside Air (%) I 0.0 Total Adjusted System Output 103,960 22,918 213,000 (Adjusted for Peak Design Conditions) Outside Air (cfm/sgft) I 0.00 TIME OF SYSTEM PEAK Aug 2pm I Jan 12 ami Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 69.1 OF 69.1 OF 113.6 OF Outside Air -aw, Supply Air Ducts 0 cfm Supply Fan Heating Coil 112.6 of 4500 cfm r� pOOMc `�77 69.1 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.9/77.6OF 79.0/64.4OF 79.0/64.5OF 57.2/56.1OF &Outside Air Supply Air Ducts 0 cfm § Supply Fan Cooling Coil 58.2 / 56.4 of 4500 cfm ` - 47.2% R.H. ROOMS 79.0/64.4 of 78.0 / 64.1 of Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 15 of 16 ROOM LOAD SUMMARY Cl.l IVAMt Vance Residence :M NAME Living Zone DATE ' 9/15/2005 FLOOR AREA '4 m ROOM LOAD SUMMARY ZONE NAME Addition Living Zone ROOM NAME Addition Existing Living Mult. 1 1 ROOM CFM 975 3,412 COOLING SENSIBLE 20,527 71,827 PEAK COIL LATENT CF M 153 975 8,783 3,412 COOLING SENSIBLEI 20,527 71,827 PEAK LATENT 153 8,783 COIL CFM 389 1,580 HTG. PEAK SENSIBLE 17,653 71,642 PAGE TOTAL 14,387 92,3548,936 1,969 89,296 Y TOTAL 4,387 92,354 8,9361,969 89,296 EnergyPro 3.1 By EnergySoft User Number 2655. Job Number Page 16 of 16