13320 (SFD)Building
Owner
Address
City
%a Qui
Contractor
Al. uurrett Construct; on
Addf�vs Box 3371
4
P.O. BOX 1504 N o .
ALLE 79-105 Coyote Creek LA QUINOTACCAL' FORNIA 92253
tit, -
iinistrelli Construction Co.
BUILDING: TYPE CONST. OCC: GRP.:
50-445 Mountain Shadow 769-550-628
A.P. Number
fltat a zlp 92253 T(619) 564 1849 Legal Description Lot 34 Tract 2
SFD
Project Description
City_aim Desert, & 92251 (Tel619) 564-3673
State Lia�51�3rJ City 1463
& Classif. Lic. #
-Arch., Engr., Bdrkun Group
ip
j Address Tel.
Lt! Corpora" Park
City Zip State
Srvinet CA 92714 Lia #
I LICENSED CONTRACTOR'S DECLARATION
i I hffirmathat Lam licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3•of ttie.Business and Professions Code rand my I,icense1s1In full force and
SIGNATURE DATE
i OWNER•8UIL6ER DECLARATION '
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (5100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration it work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
13320.1
5429
IUTAL I wIv+.r.v.. "7 1wr�wa*W_
REMARKS * O in puBlic places tee-
credited
eecred tett to account per agreement with
14in.istre li and City of La Quinta
Planning Department,
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setbi—,a`fTom_Center Line
Side Setback frgrn, Prop ri inn
FINAL DATE SPECTOR
Issued by:_ nom! APR 019rrwil._ II
Validated by:
Validati
ri
7�k
Sq. Ft. 327
Size
No. No. Dw.
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑
Demolition ❑
Permit does
not include block
wall
or pool.
Estimated Valuation
$167,517.00
PERMIT
AMOUNT
Plan Chk. Dep.
L3i1 •�%
Plan Chk. Bal.
01
Const.
V47.50
Mech.
3u1. 5th
Electrical
23U.19
Plumbing
7.5 U
S.M.I.
8 •
Grading
;eu . uu
Driveway Enc.
. U V
Infrastructure
L S • 1 6
Arrb In PuBItc
Places
'41b. 19
;tarts In Pub1; c Places cre lit
(218.791_
IUTAL I wIv+.r.v.. "7 1wr�wa*W_
REMARKS * O in puBlic places tee-
credited
eecred tett to account per agreement with
14in.istre li and City of La Quinta
Planning Department,
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setbi—,a`fTom_Center Line
Side Setback frgrn, Prop ri inn
FINAL DATE SPECTOR
Issued by:_ nom! APR 019rrwil._ II
Validated by:
Validati
ri
N
7�k
N
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL.. SQ. FT. ® $
UNITS
SLAB GRADE
�� r +
BONDING
YARD SPKLR SYSTEM
2ND FL. SO. FT.
FORMS
SEWER OR SEPTIC TANK
POR. SO. FT. ®
MOBILEHOME SVC.
BAR SINK
GAR. SQ. FT. ®
POWER OUTLET
ROOF DRAINS
CAR P. SQ. FT. (ol'
OTHER APP./EQUIP.
DRAINAGE PIPING
WALL SQ. FT.
TEMP. POLE
DRINKING FOUNTAIN
SQ FT ®
GROUT
URINAL
ESTIMATED CONSTRUCTION VALUATION $
FINAL INSP.
WATER PIPING
NOTE: Not to be used as property tax valuation
WATER SYSTEM
FLOOR DRAIN
MECHANICAL FEES
_$
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRYTRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SQ. FT. a c
BATH TUB
SPARK ARRESTOR
?' SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 1+/4 c
SEWAGE DISPOSAL
LATHING
SQ.FT.GAR ® 3/ec
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCKSTORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APP./EQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
Building
Address
Owner
Cf AF (AUWIU ICI�/
P.Q. BOX 1504 N o . 13320
78-105 CALLE ESTADO
79-105 Coyote Creek LA QUINTA, CALIFORNIA 92253
Ministrelli Construction Co.
Mailing
Address 50-445 Mountain Shadow
City Zllt Tel.
La Quints, �CA 92253 (619)564_1849
Contractor
Al Durrett Construction
Addre
P.s6. Box 3371
Palm Desert, t.zA 92261 (619)564-3673
State Lic. B 451035 city
1463
& Classif.
Arch., Engr.,
Designer Berkus Group
Ad ress Tel.
6 Corporate Park
City Z
IPState
Irvine, CA Lic.N
LICENSED CONTRACTOR'S DECLARATION
I hl, afilrm that I ant Ilcensad under Prot M-5 o} Chapter 9 (commencing wlm Section
7Dpp1 of talon 3 of the Ru &I and F'r°lessioes svgde and my IICenae Is In lull force and
affect.
�r.NATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm thal I am exempt lium the Contractor's License Law for the following
reason: (Sec. 7031.5,ttusruasa and Pndrsskns Cado: Any Oy or county which rua+kss ■
perm* to coiWmct, ager. tnprove, d„or,aM- or rsLWr any waicture, per lb its huUmincd of o
requires wespaiiCpnf for such perm! 10 lila ■ afprrad frJfsrtienf Wf he Is *Ceased pursue7r to
ahs prorocrta at the Confractard Lkan.e Law. ler >a icons>snryp wah Secbm 7000) of
UMalon 3 of Gra 8=kwss and Profasalvna Coda. or that he is avwnpr erererramr, and pie basks
br ahs earned exemption. Any rapgfaw of Settlor+ 7087.5 by WV 4opka* for a paamf
au6jacia the appar�rd to r � panary• or n0" mors than five lumov d dollars (6500).
❑ I, as owner of the property, o my onlyloy"s with wages as their sole compensation, will
do the work, and the elnacture Is nol Intended Or Offered for We. (SIC. 7044, samosa and
PuWesdam Code. TfM Con}rectora Lkwoip Lw does nor arply to an owner of preprrry who
E &J$r or Hprovse OW@Cn arum who aIle• Stec+ Warr htrss.s Or ffuraeupu hfs awn .npioy..a.
l rowded OW such knprovwnenrs are mf •hfmnded Of offrrsd air eels. N. howerwr, the Ek/kliq
or irpravwnwnt Is add Wahl one yw al canNepon, aIle ownee-b alder WE para ahs Braden
of pro" me he aid our bund or anpmw ft" Ura Purpose of aara-1
10 I.'= owner of the property, am axclosively contracting with licensed Conlractore to o0dr-
struct the project. fsec. 7014. drshs.a and P We=wm Cada' The C" OaC7ar'a litems taw
Apes hot apply fo an owner W properly who fauadt ar Malrawe Itivrsm, and who OU KWU fair
such propwfs with a caltreclorra) AmmodWauerk to the Cwmactar% Llcamse Law.)
❑ 1 am exempt under Sec -8. l P.C. for this mason
Data Owner
WORKERS' COMPENSATION DECLARATION
I hereby atfirm that I have a csllificste of Consent to self -Insure, or a certificate of
Wafker'e Compensation Insurance, of a certified copy thereof. (Sec. 3800, Labor Caere.)
Policy No Company
❑ Copy is filed with the city. I 1 1:artified copy is hereby fumislled.
CERTIFICATE OF MMPTION FROM
WORKERS' COMPENSATION INSURANCE _
(This section need not be completed N the permit is for we hundred do/ars (5100) valuation
or less.I
certify that in the performance ni thg work for which this permit is issued, i shall not
employ any ppeerson in any mammal so we to become subject to the workers' Compensation
Laws of Gallf0 nia.
Date Owner
NOTICE 7'O APPLICANT: If, after meanla On Certificate of Exemption you should became
subject so the W)raera' Conpenaan.•r P(oviSitins or ala Labor Code, you must fa Mwffh
comply with such provzow or tma pew rtwft be deamed rerored.
CONSTRUCTION LENDING AGENCY
1 hereby affirm that there is a car,.+fuction lending agency for the performance of the
work for which this permit is issued. 3087, Chill Codu.)
Lender's Name
Lender's Address
This is a building permit when properly flifed out, signed and validated, and is subject to
expigetion if work thereunder is suspenl.d tot 180 days.
I certify that I have read This appihcalhan snd stale that the above information is con'ect.
1 agree to comply whlh all city and c,xrnty ordinances and stale Laws quisling to building
conatru Ction, and hereby autharixe r.luesantatives W this city to enter the above,
menilorled property to Inspection purlrt+re6.
Signature of applicant_ Dale
Melling Address
City, State, Zip
i
11LDING: TYPE CONST. OCC. GRP.
P. Number 769-550-028
gal Description Lot 34 Tract 25429
oJect Description SFD -
Sq. Ft. No. No. Dw.
Size 3247 Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition
Permit does not include block wall
or pool.
511niateu Valudlioll
187 5-17.00
PERMIT
AMOUNT
Plan Chk. Dep.
250.00
Plan Chk. Bal.
-552.02
Const.
-:,,147.50
1AIfeCh,
_ 102:50
Electrical
238 A 9
Plumbing'S7
0
S.M.I.
1131rading
u.420.00
Driveway Eric.
0
Writstructure
4 r as
Arts in Publ c Places Jr
Arts i
lac -es e it _4 12--1111
TOTAL
6,411.62 6 161.62
REMARKS Arts
in public places fee
to
account per agreement -wit_:
-credited
�hiinistrelli and City of La- Quinta
Elanning DpRartment.
ZONE BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation
FINANCE
CITY OF LA OUINTA
E+OF ~ DEPARTMENT OF PLANNING & DEVELOPMENT
cif'$�,EP BUILDING DIVISION
• {��tlr.J1 �
24-HOUFfNOTICE FOR INSPECTIONS
f• r' 777-7153
Owner Ministrelli Construction
Contractor Al Durrett Construction
Permit Number 13320
POST ON JOB IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS 79-105 Coyote Creek
FD Permit does not include block wall
or pool.
TYPE OF INSPECTION DATE
FOUNDATION & SETBACK
FOOTING STEEL !'_�•
MAIN GROUND SYSTEM
GROUND PLUMBING - l
PRE-GUNITE._ "A,
DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED,}�I
CONCRETE SLAB
JOISTS & GIRDERS
ELECTRICAL GROUND WORK
DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED
ROUGH ELECTRIC +"
ROUGH PLUMBING '• :' i
ROUGH GAS & GAS TEST �� • ar {
HEATING & VENT - A/C
lYlfrAl •ne' s .•.-:..: M1
L-AOOF NO WORK UNTIL ABOVE HAS BEEN SIGNEDTERIOR
POOL FENCE & GATE
SEWER SEPTIC TANK
FI
TEMP POWER /-/� ��►//
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated 619-775-3500
Date 3/3/94 Type of Permit I La Quinta
No. 112698 Permit #
Log
Owner Name Ministrelli Construction
No. 79105 Street Coyote Creek
City La Quinta Zip 92253 Study Area 124
APN # I Tract # I J Lot # 0 Square Footage 1
Type of Development Single Family Residence I No. of units 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/ carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Mitigation Agreement
in the amount of 628.00 x 0 or $ 628.00 have been paid to D.S.U.S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By Ministrelli Construction Telephone
Name on the check
By
Dolores A. Ballesteros
Superintendent
Fee collected /exempted by Vickie J. Durrett
_ Payment Received
Signature �� Check No.5579
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./ Applicant Copy - Applicant/Receipt Copy - Accounting
0
Contractor Al Durrett Construction Address 50-445 Mountain Shadows Rd.
Owner Ministrelli Construction Co. .lob Addrestj 79-105 Coyote Creek
This form shall be posted on the jbb with the Building 2hspection Card at all times in a
conspicuous placo: It is the responsibility bf the General Contractor or the Owner/Builder
to monitor the sub-contractord that are on thin lint dto the dame persons per the
work, Any changes of thin lint mutt be Apprbved by the City of Ld Quints Department of
Building and Safety prior to work being performed by A chaHged hub-cohtractor. Failure to
comply will result in a stoppage bf work and/or the voidabdo of btilding permit.
TRADE
SUB -CONTRACTOR NAME
CONTRACTOR'S
LICENSE NO,
WORKMAN COMP,
No. ON PILE
CITY BUSINESS
LICENSE NO.
GRADE/
EXCAVATE
Emery Landclearing
800283
OTHERS
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 18 of 21
---------------------------------------------------------------------------
Project Name: LOT 34 ;Date: 3/30/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Assembly Name: R-21 Wall (W.21.2x6.16)
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: O.C.
Framing Percent: 15.0 %
Absorptivity: 0.70
Roughness: Stucco, Wood Shingles
Weight: 13.2 lb/sqft
Heat Capacity: 3.23
Th
R -Value
Construction Components
---------------------------------------------------------------------------
Fr (in)
Cavity
Frame
Outside Air Film
0.17
0.17
1. Stucco
0.875
0.17
0.17
2. Membrane, Vapor -Permeable Felt
0.010
0.06
0.06
3. Insulation, Mineral Fiber, R-21
* 5.500
21.00
5.45
4. Gypsum or Plaster Board
0.500
0.45
0.45
5.
6.
7.
8.
9.
Inside Air Film
0.68
0.68
---------------------------------------------------------------------------
Unadjusted
R -Values
22.53
6.98
ADJUSTMENT FOR FRAMING
(1 /22.53) x (0.85) + (1 / 6.98) x (0.15) =
0.059
TOTAL U -VALUE
=
0.059
TOTAL R -VALUE
=
16.89
Weight: 13.2 lb/sqft
Heat Capacity: 3.23
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 19 of 21
---------------------------------------------------------------------------
Project Name: LOT 34 ;Date: 3/30/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Assembly Name: R-21 Part.(W.21.2x6.16)
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: O.C.
Framing Percent: 15.0 %
Absorptivity: 0.20
Roughness: Smooth Plaster, Metal
Weight: 7.4 lb/sqft
Heat Capacity: 2.21
Th
R -Value
Construction Components
Fr (in)
Cavity
Frame
---------------------------------------------------------------------------
Outside Air Film
0.17
0.17
1. Gypsum or Plaster Board
0.625
0.56
0.56
2. Membrane, Vapor -Permeable Felt
0.010
0.06
0.06
3. Insulation, Mineral Fiber, R-21
* 5.500
21.00
5.45
4. Gypsum or Plaster Board
0.500
0.45
0.45
5.
6.
7.
8.
9.
Inside Air Film
0.68
0.68
---------------------------------------------------------------------------
Unadjusted
R -Values
22.92
7.37
ADJUSTMENT FOR FRAMING
(1 /22.92) x (0.85) + (1 / 7.37) x (0.15) =
0.057
TOTAL U -VALUE
=
0.057
TOTAL R -VALUE
=
17.41
Weight: 7.4 lb/sqft
Heat Capacity: 2.21
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 20 of 21
---------------------------------------------------------------------------
Project Name: LOT 34 ;Date: 3/30/1994
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Assembly Name: Tile/R-38/Gypbd
Assembly Type: Roof
Assembly Tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing: O.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 10.3 lb/sqft
Heat Capacity: 3.07
Th
R -Value
Construction Components
Fr (in)
Cavity
Frame
---------------------------------------------------------------------------
Outside Air Film
0.17
0.17
1. Roofing, Asbestos -Cement Shingles
0.250
0.21
0.21
2. Membrane, Vapor -Permeable Felt
0.010
0.06
0.06
3. Plywood
0.625
0.77
0.77
4. Insulation, Mineral Fiber, R-38
* 11.500
38.00
11.39
5. Gypsum or Plaster Board
0.500
0.45
0.45
6.
7.
8.
9.
Inside Air Film
0.61
0.61
---------------------------------------------------------------------------
Unadjusted
R -Values
40.27
13.66
ADJUSTMENT FOR FRAMING
(1 /40.27) x (0.90) + (1 /13.66) x (0.10) =
0.030
TOTAL U -VALUE
=
0.030
TOTAL R -VALUE
=
33.71
Weight: 10.3 lb/sqft
Heat Capacity: 3.07
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 21 of 21
---------------------------------------------------------------------------
Project Name: LOT 34 ;Date: 3/30/1994
Documentation: KROWN MECHANICAL DESIGN !COMPLY 24 User 2366
---------------------------------------------------------------------------
COMPONENT DESCRIPTION
-------------------------------
-------------------------------
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Assembly Name: Tile/Attic/R-38/Gypbd
Assembly Type: Roof
Assembly Tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing: O.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 7.0 lb/sqft
Heat Capacity: 1.77
Th
R -Value
Construction Components
Fr (in)
Cavity
Frame
---------------------------------------------------------------------------
Outside Air Film
0.17
0.17
1. Roofing, Asbestos -Cement Shingles
0.250
0.21
0.21
2. Membrane, Vapor -Permeable Felt
0.010
0.06
0.06
3. Plywood
0.625
0.77
0.77
4. Air Space
12.000
0.80
0.80
5. Insulation, Mineral Fiber, R-38
11.500
38.00
38.00
6. Gypsum or Plaster Board
0.500
0.45
0.45
7.
8.
9.
Inside Air Film
0.61
0.61
---------------------------------------------------------------------------
Unadjusted
R -Values
41.07
41.07
ADJUSTMENT FOR FRAMING
(1 /41.07) x (0.90) + (1 /41.07) x (0.10) =
0.024
TOTAL U -VALUE
=
0.024
TOTAL R -VALUE
=
41.07
Weight: 7.0 lb/sqft
Heat Capacity: 1.77
Shading
Shading
Table G-13: Shading Coefficients for Exterior Shading Devices with Single Pane Clear
Glazing (SCExterlor shade) '
Shading Device w/Single Pane
Clear Glass4
1) Standard Bug Screens 0.87.
2) Exterior Sunscreens with weave 53xl6finch 0.34
3) Louvered Sunscreens w/louvers as wide as openings 0.31-
4) Low Sun Angle (LSA) Louvered Sunscreens 0:15
5) Flat Roll Down Canvas Awning . 0.15
6) Outside Venetian Blinds & Rolldown Slats 0.15
1. These values may be used on line 11 of the Shading Coefficient Worksheet (Form S) to
calculate exterior shading with other glazing types and combined interior and exterior shading
with glazing.
2. Exterior operable awnings (canvas, plastic or metal), except those that roll vertically down and
cover. the entire window, should be treated as overhangs for purposes of compliance with the
Standards.
3. Standard bug screens must be assumed for all fenestration unless replaced by other exterior
shade screens: The shading coefficient listed for bug. screens is an area -weighted. value which
assumes that the screens are only on operable windows. The shading coefficient of any other
exterior shade screens applied only to some window areas must be area -weighted with the
shading coefficient of standard bug screens for all other glazing (see Weighted Averaging in
the Glossary).. Different shading conditions may also be modeled explicitly in the computer
performance method.
4. Reference glass for shading coefficients is 1/8" double strength sheet(15SS) glass.
exterior shade with 1/8" clear single pane
glass and no framing, from Table G-13 or
from manufacturer's data. If a single window
or skylight has multiple exterior shades (i.e.
shade screens and awnings) use the one with
the lower shading coefficient.
If no exterior shade is proposed, assume
standard bug screens with a shading
coefficient of 0.87. This applies to fixed
fenestration products as well as operable.
- Note that this requirement does not apply to
skylights. SCExterioi Shade for skylights
without exterior shades equals 1.0.
Glossary
12. Calculate SCShade open using values from
Items 9 and 11. The result is the combined
shading coefficient of the glazing, framing
and exterior device with the interior shade
open.
13. Calculate SCShade closed using values from
Items 10 and 11'.. The result is the combined
shading coefficient -of the glazing, framing,
interior shade and exterior shade.
These values may be used directly for the
prescriptive packages. If using the point system,
enter these values on the Fenestration Worksheet,
Form WS -3R.
Revised January 1992
G-49
Design Heat Gain
and cooling loads -are specified ... in Section
150(h) for low-rise residential buildings."
[EES, Sec. 101 ]
See also Section 2.3.
Design Heat Gain
The design heat gain is "..:the total calculated heat
gain through the building envelope under design
conditions."
[EES, Sec. 1011
See also Section 2.3.
Design Heat Loss
The design heat loss is "...the total calculated heat
loss through the .building envelope under design
conditions."
[EES, Sec. 1011
See also Section 2.3.
Directly Conditioned Space
"Directly conditioned space is an enclosed space
that is provided with wood heating,... mechanical
heating thjt has a capacity exceeding 10
Btu/(hr-ft )or... mechanical cooling that has a
capacity exceeding 5 Btu/(hr-ft2), unless the space
conditioning -system is designed.and
thermostatically controlled to maintain a process
temperature less than 55°F or greater than 90OF for
the whole space that the system serves." .
[EES, Sec. 101 ]
Dominant Occupancy
In mixed occupancy buildings, the dominant
occupancy is the occupancy type with the greatest
percentage of total conditioned floor area. See
Section 8.2.
Doors
A door is any openable opaque surface that
separates conditioned and unconditioned space.
EER (Energy Efficiency Ratio)
Glass in doors must.be counted as part of the total
fenestration area. Any door with one square foot
(144 square inches) of glass or more is required to
have a rated U -value for the entire fenestration
unit. In this case, the area to be used in the,
calculations must be the entire door area. See
Glossary Table G-12 for the shading coefficient
framing factors for glass doors.
Solid (opaque) door area is ignored in the
prescriptive packages and the point system but
"must be included in the computer performance
-approach. See Section 5.4B.
East -Facing
"East -facing is oriented to within 45 degrees of
true east, including 4500'0" south of east (SE) but .
excluding 4500'0" north.of east (NE)."
[EES, Sec. 101 ]
This definition only applies to the point system,
the prescriptive packages, and master.plart$
analyzed according to the'cardinal orientation
method. In the computer methods the actual
building orientation must. be. used, except in. the
case of master plans as stated above.
EER (Energy Efficiency Ratio)
The energy efficiency ratio (EER) is " ... the .ratio
of net cooling capacity (in Btu/hr) to total rate of
electric input (in watts) of a cooling system under
designated operating conditions, as determined
using the applicable test method in the Appliance'
Efficiency. Regulation, or Section 112."
[EES, Sec. 1011
The EERs of all central air Conditioners and
central heat pumps with output of 65,000 Btuh and
over, manufactured on or after January 1, 1992,
and all room air conditioners and room air.',
conditioner heat pumps of 200 volts or more,
manufactured on or after January 1, 1990, shall be
certified not to be less than the,following listed
values:
G-1 G Revised December 1992 Residential Manual