0007-099 (SFD) Detached Guest HouseFi
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
� L� Oi�S11�E
Signature of Contra r--22':,'14--
% • ate✓;
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
3t.REMONT COeklP&M kFI��Q dttA�-I�,3,q
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 37.00 of the Labor
Code, I shall forthwith comply with•those provisions.
Die: f! �' %' %'% Applicant
f,.
Warning: Failure to secure Workers' Compensationlcoverage is unlawful and
shall subject an employer to criminal penalties and'civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on • his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
-2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation:
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
const�pction, and hereby authorize representatives of this` City to enter upon
the above-mentioned property"forrinspection purposes!r
Signature (Owner/Agent) '"_--i! �%:- `r �' � ° M 'Date
% 1✓ s� �
BUILDING PERMIT PERMIT#
DATE VALUATION LOT 'p••.( TRACT
y Q
1.79 .4 f..
JOB SITE
APN
ADDRESS
it COYMP. CANY0X
770-240-002
OWNER
CONTRACTOR / DESIGNER / EN (NEER
DAVa) A WLERRI CHAMPS
AkWREVI PNRCE C:t7FPt7MITUN
78.49:4 COMM CANYON Ci311'RT
x#4635 DHIM" CM 0,14 RD
.A.QUINTA CA 92253
Pppe�J.111,17AA:�RARL"�CCC`yy�' L".,fa�t9l!2,�2t61
f�
(! iiW046-. 228 �.�r:T:.iJt:',` 0303 i
USE OF PERMIT
x1iYI'GM,!,Ffim[ yDw-r,ILIN1131%
lIMT t UuF_P_ WtP IGQttA
VMMIATED COST OF C11 ONMUC, MDR
CONS'ITRUCTION.' YtI,Y 10) -OW -418-0100 $4100
4/i,;AN C H..WK. FEE '101400-439- 318 $330.90
;dR4PCHAVI.CAL• FEE 101.000.421.000 $39„ 4
FLIC'f.'RI011t, M C lir -0 00-420-000 $4.4.62
Irl i3;AD SIC Yap, 101-000-419-000 W.00
STIZ0140 MOTION IME - RZ310 101 -000 -241 -WO $4.92
4:��.i�.� /���f' �''�L�'. �I 'A� } ^�}t{�)^�:.1�r�9J.,lJf,lO �:�•���
i-�- roa ta , C:Ciws'? u'=oN Am Pl:.t.'41.+I' o`9r'W =
$909.44
MISS M 1PAW 3.41
$0.00
'.f'MAL r wffrIP EN DKIES NOW
�§►t#��,54
RECEIPT
DATEtff)�y/yj
BYE l
DATE FINALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck/ Z �) �B s7
O.K. to Wrap
Exhaust Fans
F.A.U. .
Framingq
Insulation
I vC iQ ?
Compressor
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL
APPROVALS
steel
Set Backs
Electric Bond
Footings
Bond Beam
_ _
Main Drain
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
I
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Water Piping
_ _
( —� S%
Heater Final
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
I 1=1_p p g?
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final _
Utility Notice (Perm) Y��
Bin #
'Permtt #
000-7
Building Pe
Project Address:
Tel
A. P. Number:
Legal Description:
Contractor:
Address:
Cir% -.ST. Zip:
Teiephone?1140),����
... .. ..
State Lic. 0
City Lic. #:
Arch.. Enar.. Designer:
Address:
Ciry. ST. Zip:
Telephone:to
State Lic.
Name of Contact Person:
Telephone of Contact Person:
3 Z
..........
PPL
Subminal.
.........
-plan
Pl r
-I rasa axa
Titit. 24 -Cal
Gran'tDta.
'Sihno, fftO
Oy Busine
P,
City of La Quints
Building 9Z Safety Division.
P.O. Box 1504
78.495 Calle Tampico
La Quinta, CA 92253
rmit Application and Tracking Sheet
owner's Name: J*V I r> 5
Address: 4!2YOMF_ e4ofiv VOAJ —eia
CitysT. Zip:
41
Project Description:
Irl Ar, A OK)
1Avp 2000—.
I
Construction Type:occupancy: .5;F9
1
Project type (circle one): New Add'n Alter Repair Derno
Sq. FL: D-2-7 # Stories: I I if Units-
Estintated Value of Project:
BE=Ilii
Iffills I WARROMMEM
09/27:00 10:28 FAX 909 890 3612 FIDELITY
c�
F�3T►C.,
RECORDING REQUESTED BY:
City of La Quinta
Community Development Department
La Quinta, CA 92253
WHEN RECORDED PLEASE MAIL TO:
City of La Quinta
Community Development Department
c/o Greg Trousdell
P.O. Box 1504
La Quinta, CA 92253
U002
COVENANT AND AGREEMENT RESTRICTING THE USE OF TETE RE, SIDENCE AT 78&_.
495 COYOTE CANYON COURT, LA QUINTA, CALIFORNIA
This covenant and agreement is made and executed on this the 29t° day of August, 2000, by
David Chapman for property described herein. The City of La Quinta, a Municipal Corporation, is
hereby made a party to this agreement for the purposes set forth below.
The undersigned hereby certifies that he is the property owner of the following described real
property in the City of La Quinta, County of Riverside, State of California:
Lot 44 of Tract No. 28470-1 in the City of. La Quinta, County of Riverside
1n.consideration of the City of La Quinta issuing a building permit for certain improvements
Which will be constructed on saidproperty, the undersigned does hereby covenant and agree to and
with said City to restrict the use of said property as follows:
1. The detached guest house may not be rented nor sold independent of the main single
family residence (Minor Use Permit No. 2000-231);
2. No kitchen or cooking facilities shall be constructed in the guest house per the
provisions of Chapters 9.30.030 (RL Zone District) and 9.60.100 (Guest >-louses) of.
the La Quinta Municipal Code; and,
3. All on-site facilities are intended for the sole occupancy of the property owner(s),
nonpaying guests, and domestic employees.
This covenant and agreement shall run with the land and shallbe binding upon future owners,
their successors, heirs, or assigns, and ourselves, and shall continue in effect while said accessory
building remains on the real property or unless otherwise released by the authority of the City of La
Quinta. All leases of said dwelling and/or property shall be subject to this restriction. , This
Coven231 -p
09-27-00 11:23
RECEIVED FROM:909 890 3612
P•02
09/27:00 10:28 FAX 909 890 3812 FIDELITY 16 003
agreement shall be entitled to the remedy of injunctive relief in addition of any remedy in law or
equity.
This covenant and agreement and the provisions hereof are irrevocable and nonmodifiable
except by the written consent of all parties to the agreement, including the City of La Quinta, a
municipal corporation. The City sball have the right to enforce each and every provision hereof and
the parties agree that the agreement shall not be rescinded, revoked, modified, or otherwise amended.
or changed, without the expressed written consent of the City first being obtained.
Tn the event that the owners, their heirs, assigecldi
ssors in interest, shall fail to perform
any obligation hereunder, They hereby agree to pay alexpenses incurred by the City of La
Quinta in securing performance of such obligation,att�y%�s.
S ¢ 20 2 0
Dated.
Notary
Cove)M 1'-P
0
By:
David Chapman
IM
By: OLJS,-;�
Christine di Iorio, Planning Manager
City of La Quinta
09-27-00 11:23 RECEIVED FROM:909 890 3612 P.03
09%27.00 10:29 Fa1 909 390 3612 FIDELITY 16 004
CALIFORNIA ALL-PURPOSE ACKNOWLEDGMENT
State of -California
ss.
County of
On - Df before me,� DreS A407�Zrll LC��
X816 / NPmo and 7.U' of Officer (e.g., ane Do�lUC !
personally appeared
CHRISTINA J. DORS
Comrntutan 01127459
Notary Pubk - Coilks,io
RIV031de County
IMTComm.6Wl1wFeb21],=
I'IBCa No1Bry Saal Above
Lt personalty known to me
0 proved to me on the basis of satisfactory
evidence
to be the person() whose named islafe
subscribed to the within instrument and
acknowledged to me that he/64el h%Lexecuted
the same in his/heir authorized
capacity(+es), and that by hisiliefAlgeir
signature(e) on the instrument the person(e), or
the entity upon behalf of which the person4e4
acted, executed the instrument.
WIT SS my hand officials I.
OPTIONAL
Though the information below is not required bylaw, it may prove valuable to persons relying on the document
and could prevent fraudulent removal and reatlachment of this form to another document.
Description of Attached DocumentL�'
Document Date: t�1 Z� 9 �?O_�� Number of Pages: -
Signer(s) Other Than Named Above: �-5r1
Capacity(ies) Claimed by Signe
signer's Name:
ti
individual Top of Thumb hors
IJ Corporate Officer — Title(s):
F! Partner — I] Limited I I General
L] Attorney In Fact
IJ Trustee
❑ Guardian or Conservator
❑ Other:
Signer Is Representing:
01999 Nnllono1NOWyk3ovfiUn•G=00S010AV00.RaBOX 241E-ChUP011h,CA9`1313-2409.- M .=1kM rcluYh19 P.&No. 8997 FUoleor.CooToU.Floo1•BD04784U_07
09-27-00 11:23 RECEIVED FROM:909 890 3612 P.04
09'27/00 10:29 FAX 909 890 3812
State of California
County of Riverside
FIDELITY
l¢JUUS
On 1/31 1 t o before me, PhpRis Manley, Notary Public, personally appeared
Christine L. di Yorio, personally known to me to be the person whose name is subscribed to the
within instrument and acknowledged to me that she executed the same in her authorized capacity,
and that by her signature on the instrument the person or the entity upon behalf of which the person
acted, executed the instrument.
'WITNESS my hand and official seal. (Seal)
nlYL S MANLEY
oammBrlon * »"M
"Okly PLOC • caakmb
Rtverstde County
-Arcar��sOc116,�
09-27-00 11:24 RECEIVED FROM:909 890 3612 P.05
State of California
County of Riverside
On gl3 I o o before me, Phyllis Manley, Notary Public, personally appeared
Christine L. di Iorio, personally known to me to be the person whose name is subscribed to the
within instrument and acknowledged to me that she executed the same in her authorized capacity,
and that by her signature on the instrument the person or the entity upon behalf of which the person
acted, executed the instrument.
WITNESS my hand and official seal. (Seal)
��~/ •• •r ,11/
Desert Sands Unified School District
47-950 Dune Palms Road
Notice: La Quinta, CA 92253
Document Cannot Be Duplicated 760-771-8515
CERTIFICATE OF COMPLIANCE
Date 10/24/00
No. 21133
Owner NameDavid & Sheri Chapman
No. 78-495 Street Coyote Canyon Court
City La Quinta
Tract # 28470-1
Lot # 44
APN # 770-240-002
Jurisdiction La Quinta
Permit #
Log #
Zip 92253 Study Area
Square Footage 632
Type of Development Residential Addition No. of Units 1
Comments
is a detached guest house.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of
2.05 X 632 or $ 1,295.60 the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Fees Paid By CC / Palm Desert National Bank / Christina Dores
Name on the check
By Dr. Doris Wilson
Superintendent
Fee collected /exem ted by Annette Barlow
Signature &L,
Payment Received
Telephone
Check No. 82484
$ 1.295.60
40TICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
rbove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
milect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
FROM Christensen/T-24/CAEEC
FAX NO. : 909 763 0522 Aug. 24 2600 07:35AM F2
Carole Christensen, Certried.Lnepgy Analyst.
Title -24 ,Energy Calculations August 25, 2000
! ENERGY CALCULATIONS FOR:
PROJECT:
Standard
98.93
Stein & Associates
41-945 Boardwalk, Suite 1{,
Palm Desert, Ca. 92211
Chapinan 632 Sq,ft. Guest House
78-495 Coyote Canyon Court
La Quints, CA
Proposed
95.38
CTZ-15; 26.5'%, fencstration
Dual metal fenestration, Lt Blind
Wood French Doors, Std Drape
Wa1.Is R-1.9; Aoof R-38; DuctR-4.2
AF(l1.=.-80%, SEER 12.0
One 40 gal 4,&s water hea.tcr, , EF .60
Table of Contents
CF -IR
N4F-1 R
C -2,R
3-R
HVAC
Commliance
+0.55
OFFS r -E C,av Y
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE
47-596 Lake Canyon J>ive, . giianra, CA 925. 6
1-900-735-9152.
A%n:ber• C lI BEC - CadiJi�rrria , (.tisv� icrNorr of Guflding Enewty CO)IS 10,1 $
BY
FRO11 : C1•,ristensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:36Ah1 F3
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title......... Chapman Guest House Date..08/24/00 08:24:55
Project Address........ 78-495 Coyote Canyon CL' *******
La Quinta, CA *v5.10*
Documentation Author... Carole Christensen ******* Building PerniT
Carole Christensen
47-596 Lake Canyon Drive Plan Check Date
Aguanga., CA 92536
800-735-8152 Fie C eC Date
Climate zone. ..... is
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.10 File-CHPMNGST wth-CT215992 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen Run-V8F80.12R19.38.4 Std
GENERAL INFORMATION
Conditioned Floor Area_....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of stories..........
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -value....
Average Glazing SHGC.......
Average Ceiling Height.....
632 sf
Single Family Detached
New
Front Facing 0 deg (N)
1
1
Slab On Grade
27.8 % of floor area
0.62 Btu/hr-sf-F
0.64
10 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing
Type
Type
R -value
R -value
Wall
Wood
R-17.8
R-0
Wall
Wood
R-17.8
R-0
Roof
Wood
R-11
R-27
SlabEdge
n/a
R-0
R-n/a
SlabEdge
n/a
R-0
R-n/a
Orientation
Window
Front
(N)
Window
Front
(N)
Window
Front
(N)
Window
Left
(E)
Door
Left
(E)
Door
Back
(S)
Window
Right
(W)
Total Assembly
R -value U -value Location/Comments
R-17.8 0.065
R-17.8 . 0.064 to meth
R-38 0.025 attic
F2=0.720 to outside
F2=0.500 to garage
FENESTRATION
Area U- Tnterior
(sf) Value SHGC Shading
3.8 0.730 0.610 Blind
3.8 0.730 0.610 BlJ.nd
30.0 0.730 0.610 Blind
30.0 0.730 0.610 Blind
48.0 0.550 0.650 Standard
48.0 0.550 0.650 Standard
12.0 0.600 0.710 Blind
Over -
Exterior
Shading
hang/
Fins
Standard
None
Standard
None
Standard
None
Standard
None
Standard
None
Standard
None
Standard
None
FROM : Chr•iStensen/T-24/CAEEC FAX NO. : 909 763 0522 Aug. 24 2000 07:3GAM P4
CERTIFICATE OF COMPLIANCE: RESIDENTIAL page 2 CF -1R
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
MICROPASS v5.10 File-CHPMNGST Wth-CT23.SS.92 Program -FORM CF -1R
User$#-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
SLAB SURFACES
Area
Slab Type (sf)
Standard Slab 632
HVAC SYSTEMS
Minimum Duct Duct Tested Duct ACCA Thermostat
Equipment Type Efficiency Location R -value Leakage Manual D Type
Furnace 0.800 AFUE Attic R-4.2 No No Setback
ACSplit 12.00 SEER Attic R-4.2 No No Setback
WATER HEATING SYSTEMS
Number Tank External
,in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
Storage Gas Standard 1 0.60 40 R- n./a
REMARKS
Milgard fenestration or better - Metal framed windows
Wood French Doors
-ROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:37AM P5
:CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -IR
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
MICROPAS5 v5.10 'File-CHPMNGST Wth-CTZ15S92 Program -FORM CF -1R
User##-MP1017 User -Carole Christensen Run=VBF80.12R19.38.4 Std
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -7.4, Parts I and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility, when this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
Name....
Company.
Address.
Phone...
License.
Signed.
DESIGNER or OWNER
Gordon Stein 'N'ame....
Stein & Associates Company.
41-945 Boardwalk, Ste K Address.
Palm Desert, CA 92211
(760) 568-3696 Phone..,
DOCUMENTATION AUTHOR
Carole Christensen
Carole Christensen
47-596 Lake Canyon Drive
Aguanga, CA 92536
800-735-8152
AV
Signed..
ate ate
AGENCY
Name....
Title...
Agency..
Phone...
Signed..
ate
Certified Energy Analyst
Carole Christensen, CEPS
r r . R M99.239
C A 0 E C
Callfomin Amodanon of [lauding Energy Comircros
PROM : Cl-)i^iStansen/T-24/CAl3EC FAX NO. : 909 763 0522 Aug. 24 2000 O7:37AM P6
MANDATORY MEASURES CHECKLIST: RESIDENTIAL (;Page t of 2) MF -1R
Note: I,owrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
ms marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance, When this checklist is incorporated into the permit documents, the features noted shall be considered by all panics as
minimum component performance specifications for the mandatory measures whether they are shown etsewhero in the documents
or on this checklist only.
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Building Envelope Measures,
§150(a): Minimum R-19 calling insulation,
V-,'
§ 150(b): Loose rill insulation manufacturer's labeled R -Value,
N14-1
• §1$0(c): Minimum R -a 3 wall insulation in wood framed walls or equivalent U -value in metal Game walls
(does not apply to exterior mass walls ,
§150(d): Minimum R-13 raised floor Insulation in framed floors,
N ,
§ 1500) : Slab edge insulation - water absorption rate no greater than USK, water vapor transmission rate
no greater than 2.0 permAnch.
a/
§ I 19: Insulation specified or installed meets Insulation quality standards. Indicate type and form,
§ 116-17: Fenestration Products, Exterior Doors, and InfiltratiordWiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage,
2. Fenestration products (except field-fabricated)have label with certified U -value, certified Solar Heat
Gain Coefficient ($HOC), and infiltration certification.
3, Exterior doors arid windows woatherstrippcd; alt joints and penetrations caulked and sealed.
y�
Vapor barriers mandatory in Climate Zones 14 and 16 only,
§ 150(f): special infiltration barrier installed to comply with § 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gras Logs,
1, Masonry and factory -built fireplaces have;
a. Closeable metal or glass door
b, Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilot lights allowed,
Space Conditioning, Water Keating and Plumbing System Measures:
1110-1113: HVAC equipment, water heaters, ahoworheads and faucets cettifled by the Commission,
§ I50(h): Heating and/or cooling loads calculated In accordance with ASHRAR, SMACNA or RCCA.
§ l SO(l): Setback thermostat on all applicable heating and/or cooling systems.
§ 150Q): Pipe and tank insulation
1. Storage gas water heaters rated with an Energy Factor less than 0,53 must be externally wrapped with
insulation having an Installed thermal resistance of R-12 or greater.
2, First 5 Feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Sack -up tanks for solar system, unfired Storage tanks, or other indirect hot water tanks have R -l2
external insulation or R•16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5, L ag system piping below 55° F Insulated,
l
6. Pipfnk insulated between heating source and indirect hot water tank.
July 1. 1999
FROM Christensen/T-24/CABEC
FAX NO. : 909 763 0522 Aug. 24 2000 07:37AM F7
MANDAT'OR'Y MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) MF -1R
Note: Lowrist residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.
Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of
Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all panics as
minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents
or on this checklist only,
Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable.
DESCRIPTION
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
' § 150(m): Ducts and Fans
I, Ali ducts and plenums constructed, installed, Insulated, fastened, and sealed to comply with the ICBG
1997 UMC sections 601 and 603; ducts insulated to a minimum installed R-4,2 or ducts enclosed
entirely within conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other
duct closure system that meets the applicable requiremetns of UL181, UL 181 A, or UL1818 and other
applicable specified tests for longevity given in §I50(m)..
2. Exhaust fan systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
/
manually operated dampers.
1/
§ 114: Pool and Spa heating Systems and Equipment.
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating
instructions, no electric resistance heating and no pilot light,
2. System is installed with:
At least 36" of pipe between filter and heater for future solar heating.
" b. Cover for outdoor pools or outdoor spas.
- 3. Pool system has directionat inlets and a circuletlon pump time switch.
§ 1 15: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
/
continuously burning pilot light. (Exception: Non-eloctrical cooking appliances with pilot < 150 Btu/hr)
t/
Lighting Measures:
§150(k)I,: Luminaires for general lighting in kitchens shall have lamps within efficacy or40
lumensJwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a
switch on a readily accessible, lighting control panel at an ertranoe to the kitchen.
f/
150(k)2.: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an
efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to
this requirement allowed in § I50(k)2.; and recessed ceiling fixtures aro IC (insulation cover) approved.
.1211v 1 1000
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:39AM PS
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
Project Address......,, 78-495 Coyote Canyon Ct *******
La Quinta, CA *v5.10*
Documentation Author... Carole Christensen ******* Building Permit
Carole Christensen
47-596 bake Canyon Drive Plan Check Date
Aguan:ga, CA 92536
800-735-8152 Field Check/ Date
Climate Zone. ...... 15
Compliance Method...... MICROPAS5 x5.10 for 1998 Standards by Enercomp, Inc.
MZCROPAS5 v5.10 File-CHPMNOST Wth-CTZl5S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen Run-VBF80.12RI9.38.4 .Std
MICROPASS ENERGY USE S'U'MMARY
Energy Use
(kBtu/sf-yr)
Space Heating.......,.,
Space Cooling..........
Water Heating..........
Zane Type
HOUSE
Residence
Total
Standard
Proposed
Compliance
Design
Design
Margin
4.74
3.56
1.18
63.44
68.84
-5.40
30.75
25.9$
4,77
98.93
98.38
0.55
*** Building complies with Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type ...
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned volume.........
Slab -on -Grades Area.........
Glazing Percentage. .......
,Average Glazing U -value....
Average Glazing SHGC.......
Average Ceiling Height.....
632 sf
Single Family Detached
New
Front Facing 0 deg (N)
1
1
ReducedYear
Slab On Grade
1
6320 cf
632 sf
27.8 6 of floor area
0.62 Btu/hr-sf-F
0.64
10 ft
BUILDING ZONE INFORMATION
Floor ## of
Area Volume ]Dwell
(sf) (Cf) Units
632 6320 1.00
Cond- Thermostat
itioned Type
Yes Setback
Vent
Vent
Air
Height
Area
Leakage
(ft)
(8f)
Credit
2.0
Standard
No
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:38AM F9
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
MICROPASS v5.10 File-CHPMNGST Wth-CTZ15S92 Program -FORM C -2R
T7ser##-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
surface
HOUSE
1 Wall
2 Wall
3 Wall
4 Wall
5 Wall
6 Roo£
Surface
OPAQUE SURFACES
Area U_ Insul Act Solar
(Sf) value R-val Aim Tilt Gains
HOUSE
7 S1abEdge
8 SlabEdge
Orientation
MOUSE
1 Window
2 Window
3 Window
4 Window
5 Door
6 Door
7 Window
System Type
HOUSE
Furnace
ACSplit
Form 3 Location/
Reference Comments
238
0.065
17.8
0
90
Yes
W.19.2X6.16
247
0.065
17.8
90
90
Yes
W.19.2X6,16
227
0.065
17.8
180
90
Yes
W.19.2X6.16
253
0.065
17.8
270
90
'Yes
W.19.2X6.16
130
0.064
17.8
0
90
leo
GWALL.R19 to mech
632
0.025
38
n/a
0
Yes
R.38.2X4.24 attic
PERIMETER LOSSES
Length
F2
Insul
(ft)
Factor
R-val
114
0.720
R-0
13
0.500
R-0
Solar
Gains Location/Comments
No to outside
No to garage
FENESTRATION SURFACES
Area U- Act Exterior Shade Interior Shade
(sf) Value SHGC Azm 'Tilt Type/SHGC Type/SHGC
Front
(N)
3.8
0.730
0.610
0
90
Standard/0.76
Blind/0.47
Front
(N)
3.8
0.730
0,610
0
90
Standard/0.76
Blind/0.47
Front
(N)
30.0
0.730
0.610
0
90
Standard/0.76
Blind/0.47
Left
(E)
30.0
0.7,10
0.61.0
90
90
Standard/0.76
Blind/0.47
Left
(E)
48.0
0.550
0.650
90
90
Standard/0.76
Standard/0.68
Back
(S)
48.0
0.550
0.650
180
90
Standard/0.76
Standard/0.68
Right
(W)
12.0
0.600
0.710
270
90
Standard/0.76
Blind/0.47
SLAB
SURFACES
.Area
Slab
Type
(sf)
HOUSE
Standard
Slab
632
RVAC SYSTEMS
Minimum
Duct
Duct
Tested Duct
ACCA Duct
Efficiency
Location
R -value Leakage Manual D Ef€
0.800 AFUE Attic
12.00 SEER Attic_
R-4.2 No No 0.743
R-4.2 No No 0.596
FROM : Christensen/T-24/CAEEC FAX NO. : 909 763 0522 Aug. 24 2000 07:39AM P10
'COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
MICROPA,SS v5.10 File-CHPMNGST wth-CTz1SS92 Program -FORM C -2R
User4-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
WATER HEA"I'ING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Storage Gas Standard .1` 0.60 40 R- n/a
Milgard fenestration or better -
wood'French Doors
REMARKS
Metal framed windows
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:39AM P11
CONSTRUCTION ASSEMBLY Page 1 3R
Project Title.......... Chapman Guest House Date..08/24/00 08:24:55
MICROPASS v5.10 File-CHPMNGST Wth-CTZ15S92 Program -FORM 3R
User##-MP1017 User -Carole. Christensen Run-VBF80.12R19.38.4 Std
Parallel Path Method
Reference Name . W.19.2X6.16
Description .... Wall R-19 2x6 160c
Type ........... Wall
R -Value ........ 17.8 Hr-sf-F/Btu
Framing
Material ..... FIR.2X6
Type ........ 'W'ood
Description .. 2x6 fir
Spacing ...... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material Cavity Frame
Name Description R. -Value R -Value
0. FILM. EX
1. STUCCO. 0.88
2. BLDG.PAPER
3c. BATT.R19
3f. FIR.2X6
4. GYP.0.50
I. FILM.IN.WLL
Exterior air film: winter value
0.17
0.17
0.875 in stucco
0.17
0.17
Building paper (felt)
0.06
0.06
R-19 batt insul (cavity = 5.5 in.)
17.80
--
2x6 fir
--
5.45
0.50 in gypsum or plaster board
0.45
0.45
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values 19.34 6.98
FRAMING ADJUSTMENT CALCULATION
Cavity Praming Total
U -Value: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-F
Total R -Value: I / 0.065 = 15.28 hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX N0. : 909 763 0522 Aug. 24 2000 07:39AM P12
CONSTRUCTION ASSEMBLY Page 2 3R
Project Title.......... Chapman Guest House. Date..08/24/00 08:24:55
MICROPAS5 v5.10 File-CHPMNGST Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
Parallel Path Method
Reference Name . GWALL.R19
Description .... Wall R-19 2x6 16oc
Type ........... Wall
R -Value ........ 17.8 Hr-sf-F/Btu
Framing
Material FIR.2X6
Type ........ Wood
Description .. 2x6 fir
Spacing ..... 16 inches on center
Framing Frac.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material Cavity
Name Description R -value
0, FILM. EX
1. GYP, 0.50
3c. BATT.R19
3f. FIR. 2X6
4. GYP. 0.50
I. FILM.IN.WLL
Exterior air film: winter value
0.50 in gypsum or I)Laster board
IZ-19 batt insul (ca* vitt' = 5.5 in)
2x6 fir
0.50 in gypsum or plaster board
Inside air film: heat sideways
Total Unadjusted R -Values
FRAMING ADJUSTMENT CALCULATION
Cavity Framing
U -Value: (1 / 19.55 x 0.85) + (1 / 7.19 x 0.15) _
0.17
0.45
17.90
0.45
0.68
19.55
Total
Frame
R -Value
0.064 Btu/hr-sf-F
Total R -Value: 1 / 0.064 = 15.55 hr-sf-F/Btu
0.17
0.45
5.45
0.45
0.68
7.19
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:40AM F13
CONSTRUCTION ASSEMBLY Page 3 3R
Project Title....,..... Chapman Guest House Date..08/24/00 08:24:55
MICROPASS v5.10 File-CHPMNGST Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
Parallel Path Method
Reference Name . R.38.2X4.24
Description Roof R-38 2X4 24oc
Type ........... Roof
R -Value ........ 38 Hr-sf-F/Btu
Framing
Material. .....
Type .........
Description ..
Spacing ......
Framing Frac..
Sketch of Construction Assembly
FIR. 2X4
Wood
2x4 f it
24 inches on center
0.07
LIST
OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
SHNGL.ASPHLT
Asphalt shingle rooting
0.44
0.44
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5.
BATT.R27.0
R-27 batt insulation
27,00
27.00
6c.
BATT.R11.0
R-11 batt insul (cavity > 3.5 in)
11.00
--
6f.
FIR.2X4
2x4 fir
--
3.46
7.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.161
0.61
Total Unadjusted R -Values
41.15
33.62
FRAMING ADJUSTMENT CALCULATION
Cavity
Framing
Total
U -Value: (1 / 41.15 x 0.93) + (1 / 33.62 x 0.07) = 0.025 Btu/hr-sf-F
Total R -Value: 1 / 0.025 = 40.51 hr-sf-F/Btu
FROM : Christensen/T-24/CABEC FAX NO. : 909 763 0522 Aug. 24 2000 07:40AM P14
HVAC SIZING Page 1 HVAC
Project Title.......... Chapman Guest; House Date..08/24/00 08:24:55
Project Address........ 78-495 Coyote Canyon Ct *******
La Quinta, CA *v5.10*
Documentation Author... Carole Christensen Builaing Permit
Carole Christensen
47-596 Lake Canyon Drive Plan Check Date
Aguanga, CA 92536
800-735-8152 Field Check/ Date
Climate Zone. ..... 15
Compliance Method...... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
MICROPAS5 v5.1.0 File-CHPMNGST Wth-CTZ1SS92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen Run-VBF80.12R19.38.4 Std
GENERAL INFORMATION
Floor Area ................. 632 sf
Volume ..................... 6320 cf
Front Orientation.......... Front Facing 0 deg (N)
Sizing Location............
PALM DESERT
Latitude... ............
33.7 degrees
Winter Outside Design......
32 F
Winter Inside Design.......
70 F
Summer Outside Design......
112 F
Summer Inside Design.......
78 F
Summer Range ...............
34 F
Interior Shading Used......
No
Exterior Shading Used......
No
Overhang Shading Used......
No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Heating Cooling
Description (Btuh) (Btuh)
Opaque Conduction and Solar...... 6675 3085
Glazing Conduction ............... 4152 3715
Glazing Solar .................... n/a 6651
Infiltration ..................... 3337 2209
Internal Gain .................... n/a 2100
Ducts ............................ 1417 1776
Sensible Load .................... 15582 19536
Latent Load ...................... n/a 3907
Minimum Total Load 15582 23443
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdogy design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., most also be
considered. It is the HVAC designer's responsibility to consider all