Loading...
BRES2014-115878-495 CALLE TAMPICO LA QUINTA, CALIFORN!,W2253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: DESERT BUILDERS INC 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 Twy444umro COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BRES2014-1158 78400 COYOTE CANYON CT CT 770240010 STERIN RESIDENCE $10,000.00 A DEC 18 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Cla s: _ License No.: :LIC -0107616 Date: � Contractor: JkA,01,. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the*[ basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for �` permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/18/2014 Owner: JEANNE MIRAGLIA P 0 BOX 3070 INCLINE VILLAGE, NV 92253 Contractor: DESERT BUILDERS INC 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 (760)568-1790 Llc. No.: :LIC -0107616 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which.this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ►► .. -- nn Date: 2 M Applicant: � ltoo� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for.180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: le' Signature (Applicant or Agent):A..S,� FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA A,DtFT1OWAL 500 SF 101-0000-42400 0 $62.36 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 PAID BY METHOD RECEIPT. # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forADDITION: $371.73 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY, AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION, _ ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $33.84 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION. ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PLUMBING FEES: $72.54 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $1.30 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMt $1.30 $0.00 • • $0.00 Description: STERIN RESIDENCE Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 10/31/2014 AZA Approved: Parcel No: 770240010 Site Address: 78400 COYOTE CANYON CT CTLA QUINTA,CA 92253 Subdivision: TR 28470-1 Block: Lot: 52 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 JL Details: CONVERSION OF A GOLF CART GARAGE TO A BATHROOM. ENCLOSURE OF A BREEZEWAY INTO A GAMEROOM. Printed: Thursday, December 18, 2014 1:06:34 PM 1 of 4 CRIA1sysTEms ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 11/10/2014 11/10/2014 STRUC APPROVABLE 11/10/14 RECEIVED PLAN CHECK PICKED UP KAY HENSEL 11/12/2014 11/12/2014 PLAN CHECK SUBMITTAL RECEIVED 1ST PLAN CHECK SUBMITTAL FROM EDUARDO RECEIVED ANGELICA ZARCO 10/31/2014 10/31/2014 ESCOBAR. RESUBMITTAL KAY HENSEL 11/19/2014 SENT TO PLAN CHECK KAY HENSEL 11/3/2014 11/3/2014 STRUC TO YOUNG DUE 11/14 CONSULTANT LEFT MESSAGE FOR EDUARDO ESCOBAR THAT PLANS ARE TELEPHONE CALL ARMEN ALTOUNIAN 11/12/2014 11/12/2014 READY TO PICK UP. TELEPHONE CALL ARMEN ALTOUNIAN 11/20/2014 11/20/2014 PLANS READY FOR PICK UP. Printed: Thursday, December 18, 2014 1:06:34 PM 1 of 4 CRIA1sysTEms Printed: Thursday, December 18, 2014 1:06:34 PM 2 of 4 C82"WsrsTEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT PAID ' PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY ADDITION, EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 0 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $371.73 $0.00 BSAS S61473 FEE 101-0000-20306 1 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,OOOSF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 APPLIANCE 101-0000-42402 0 $12.09 $0.00 REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83 $0.00 REPAIR/ALTERATION PC VENT FAN 101-0000-42402 0 $12.09 $0.00 Printed: Thursday, December 18, 2014 1:06:34 PM 2 of 4 C82"WsrsTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD DUE DATE RETURNED REVIEWS STATUS REMARKS NOTES DATE BY VENT FAN PC 101-0000-42600 0 $4.83 $0.00 11/14/2014 11/12/2014 REVISIONS REQUIRED 1ST PLAN CHECK NON-STRUCTURAL Total Paid for MECHANICAL: $33.84 $0.00 FIXTURE/TRAP 101-0000-02401 0 $36.27 $0.00 BUCKET FIXTURE/TRAP PC 101-0000-42600 0 $36.27 $0.00 STRUC TO YOUNG, DUE 11/14/14 STRUCTURAL Total Paid for PLUMBING FEES: $72.54 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $1.30 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $1.30 $0.00 TOTALS:00 2ND PLAN CHECK RESUBMITTAL AT FRONT COUNTER BY SK. NON-STRUCTURAL INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES APPROVED DATE DATE FINAL*" ALTOUNIAN Printed: Thursday, December 18, 20141:06:34 PM 3 of 4 CRWrsren S PARENT PROJECTS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED REVIEWS STATUS REMARKS NOTES DATE BUILDING 10/31/2014 11/14/2014 11/12/2014 REVISIONS REQUIRED 1ST PLAN CHECK NON-STRUCTURAL RFC BUCKET BUILDING STRUC TO YOUNG, DUE 11/14/14 STRUCTURAL 10/31/2014 11/14/2014 11/3/2014 APPROVED STRUC APPROVED 11/10/14 BUCKET ARMEN 2ND PLAN CHECK RESUBMITTAL AT FRONT COUNTER BY SK. NON-STRUCTURAL 11/19/2014 12/3/2014 11/20/2014 APPROVED 2ND PLAN CHECK APPROVED ALTOUNIAN APPROVED Printed: Thursday, December 18, 20141:06:34 PM 3 of 4 CRWrsren S Printed: Thursday, December 18, 2014 1:06:34 PM 4 of 4 CRsrsreMs RF-n.CF/SFO oty of La Quinta - 3z 2�11 0 -Buikrtpg 8z safety Division visi6n � VVA; OF 14 PeriWt # P.O. Box 1504,"78-495 Calle Tamptco LR.Quinta, CA 92253 -:(760) 777-7012 Tq 4"ZOPML, W14-- Building Pennit Application' and Tracking Sheet M Project Address: '7Sq00 czNort� CA-"NOAj Owner's Name:. j-j11rAjizj k- sf;er-jio A. P. Number- o -2-z4 o - 0 1 L-) Address: Legal Description: 7-5400-1 City, ST, Zip: t 4oW'r.4- C&. Contractor. Contracto x teitphone: 111 IN Pmjer4'Description: F C49 -T- Cj4A*TC;- Address: u!4 A City, ST, Zip: &4C Telephone: Vm, U. -M, State Lic. # : *712. ity L City L C Arch, Eng., Designer. Address: q39z? PC l"F?Avc- • City., ST, Zip: a GF- Q1i2ol Telephone: -9 .0-Z-0?-jZZjConstruction State l,ic.#:Project Type:. V -Al Occupancy: type (circle one): Now d Ktep Repair Demo' Sq. Ft.: Stories: t # Units: Name of Contact Person: Telephone# of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # "Submittal Req1d Rec'd TRACKNG PERMIT FEES -iJ—pl_ Sets Plan Check submitted. item Amount Structural Cales. Reviewed, ready for corrections PI.. Check Deposit. Truss CaIcs. Called Contact Person Plan Check Balance - Title 24 Cald. Plans picked up construction Flood plain plan Plans resubmitted.*. Mechniw Grading plan V Review, ready for correctionslissue Electrical Subcontattor List Called Contact Person Plumbing Grant Deed Plans picked up S.NLL H.O.A. Approval Plans resubmitted Grading M HOUSE- Review; ready for correctionsirissue Developer Impact Fee Planning Approval Called Contact Person AXP -P - Pub. talcs. Appr Date of permit Issue School Fees Total Permit Few' /4 t �t�c �l� ---------- - Date 12/17/14 No. 31658 Owner Sterin Address 78-400 Coyote Canyon City La Quinta Zip Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units 4����Ft�vso�o Q BERMUDA DUNES RANCHO MIRAGE t.J INDIAN WELLS PALM DESERTLA QU IN ��aINDDIOT � 770-240-010 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 78400 Coyote Canyon 371 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 371 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Brandon Davis Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt BY Dr. Gary Rutherford Superintendent Fee collecte Payment Recd $0.0 ' ;'Over/Urider� Signature NOTICE: Pursuant to Government Code Sebtion 66020(d)(1), this bill serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Tradition . . December 9, 2014 Mr. Henrik Stcrin, and NfsA4olly Grenfell 78400 Coyote Canyon Court 1. a Quinta, CA 92253 Re: Lot 52, Tract 28471-1, 78400 Coyote Canyon Architectural Addition - Dear Mr. Sterin and 1v1s. Grenfell: ')'his correspondence shall serve as notification from the Tradition Architectural .Design Review Committee ("AI)RC") that your architectural addition %vas .rcviewed at the December 4, 2014 meeting. The addition., which was completed prior to you purchasing the home, was approved as submitted. The committee appreciates you taking the time to submit the plans and update the Association's records. Please contact ,Brook. Marshall at 760-219-8057 or by email at.DR.CFacil.itator r@gmail.com with any cluestio6s regarding this matter. Sincerely, THE.TkADITIOIV4RCf...il.TL,CTUAA.L.DESIGNREIy7EiYCOAfiV]TTI,,E rl Title. L.Gi nate:. . l L, cc: AORC: -File p:vnforu to Cal. Civil Code arty rrjwfon by the ADRC may N al1maled to the Board of Directors for the ARsacintimt If frni wish to pursue an a,mmwl. please crmkaix the Association's property marnger,ta thota+o+r nut), bep+>i on the. nt;Tt meeting dj errdri. - DESERT RESORT MANAGENIENT llosrr OFFICE Box 14387 • PALhI DESERT, C,;ALIFOlkNIA 92255.4387 42-635 NttLANIE• PLACE, SUITE 103 PALM DESERT, CALIFORNIA 92211. T3:Lrn [ONE (760) .346.1161 • 1 -AX (760) 346.9918 oFi016E &VJ I BUILDING ENERGY ANALYSIS REPORT I PROJECT: MR. HENRIK STERIN - 78400 Coyote Canyon Ct. - APN. 770-240-010 La Quinta, Ca 92253 CITY OF LA QUINTA BUILDING & SAFETYDEPT. APPROVED FOR CON$TRUCTION DATE 1 i BY, Project Designer: ESCOBAR DESIGN 43927 Pacific Ave. Indio, Ca 92201 (760) 289-9221 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 1 760.485.8927 Job Number: LQ102614Corr111614 Date: 11/16/2014 EcEN R 0 19 2014 CITU OF to QUINTA ENT COMMUNIS DE\JF- I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. Won11161. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 13 Form MF -1 R Mandatory Measures Summary 15 HVAC System Heating and Cooling Loads Summary 18 EnergyPro 6.3 by EnergySoft Job Number: ID_ LQ102614Corr111614 User Number: 5732 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr1,11614.xml CF1 R -PRF -01 Page 1 of 10 GENERAL INFORMATION 01 Project Name MR. STERIN 02 Calculation Description Title 24 Analysis 03 Project Location 78400 Coyote Canyon Ct. - APN. 770-240-010 04 CA City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 .14 Total Cond. Floor Area (FT2) 5132 15 Number of Zones 4 16 Slab Area (FT2) 4761 17 Number of Stories 1 18 Addition Cond. Floor Area 371 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 371 21 Glazing Percentage (%) 120.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03. This building incorporates one or more Special Features shown below ENERGY USE SUMMARY . 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.27 1.37 -0.10 -7.9% Space Cooling 247.81 247.52 0.29 0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 9.26. 9.26 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 -- TOTAL 268.34 268.15 0.19 0.1% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 CITY OF LA QlJINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION HERS Provider: portGene ated-89 = t � ^gib CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Page 2 of 10 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corrl11614.xmi REQUIRED SPECIAL FEATURES The following are features that must be Installed as condition for meeting the modeled energy performance for this computer analysis. Exposed slab floor in conditioned zone PROJECT HERS FEATURES The following are project -level features that must be field -verified as a -condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, reciure field verification by a certified HERS Rater. Building -level Verifications: • .-None -- Cooling System Verifications: • ..None -- HVAC Distribution System Verifications: • ..None -- Domestic Hot Water System Verifications: • —None •- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components Included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)" 296.29 295.10 0.19 0.1% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING FEATURE INFORMATION 01 02 03 04 06 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems MR. STERIN 5132 1 12 4 0 1 ZONE INFORMATION 01 02 03 04 06 06 07 Zone Name Zone Type Zone Floor Area HVAC System Name (ft2) Avg. Ceiling Height Water Heating System 1 Water.Heating System 2 Mein House Conditioned HVAC System - Main Housel 4198 10 DHW Sys 1 Bath-Add'n 'Conditioned HVAC System - Main Housel 150 10 DHW Sys 1 Guest Conditioned HVAC System2 563 10 DHW Sys 1 Registration Number: Registration.Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-16 05:57:36 �t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml CF1R-PRF-01 Page 3 of.10 Seating Area-Add'n Conditioned HVAC System2 221 10 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (Wt Window and Door Area (ft2) Tllt(deg ) Status Verified Existing Condition Ri/E (E) Main House R-21 Wall, 90 Right 908.3 188.6 90 Existing No Re/N (E) Main House R-21 Wall 0 Back 1047.5 253.1 90 Existing No Le/W (E) Main House R-21 Wall 270 Left 908.3 309.8 90 Existing No Fr/S Main House R-21 Wall 180 Front 1047.5 84 90 . Existing No Roof E Main House R730 Roof Attic 1048 Existing No Roof W Main House R-30 Roof Attic 1050 Existing No Roof N Main House R-30 Roof Attic 1050 Existing No Roof S Main House R-30 Roof Attic 1050 Existing No Le/W Bath-Add'n R-21 Wall 270 Left 116.6 90 Altered . N/A Fr/S 2 Bath-Add'n R-21 Wall 180 Front 116.6 20 90 Altered N/A Roof Bath-Add'n R-38 Roof Attic 75 New N/A Roof 2 Bath-Add'n R-38 Roof Attic 75 New N/A Ri/E (E) 2 Guest R-21 Wall 90 Right 220.1 19.2 90 Existing No Re/N (E) 2 Guest R-21 Wall 0 Back 240 54.2 90 Existing No Le/W (E) 2 Guest R-21 Wall 270 Left 220.1 29 90 Existing No Fr/S (E) Guest R-21 Wall 180 Front 120 90 Existing No Roof E 2 Guest R-30 Roof Attic 281 Existing No Roof W 2 Guest R-30 Roof Attic 282 Existing No Ri/E Seating Area-Add'n R-21 Wall 90 Right 116.6 96 90 New N/A Le/W 2 Seating Area-Add'n R-21 Wall 270 Left 173.3 20 90 New N/A Roof 3 Seating Area-Add'n R-38 Roof Attic 111 New N/A Roof 4 Seating Area-Add'n R-38 Roof Attic 110 New N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-16 05:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml CF1R-PRF-01 Page 4 of 10 ATTIC 01 02 03 04 05 06 09 10 11 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condifion Attic Attic Roof Cons 4 0.1 0.85 No No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-16 05:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corrl 11614.xml CF1R-PRF-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Side of Building Width(ft Height ) (ft) Multiplie r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition (2) 2680 Fr.Dr. [E] RUE (E) ---- ---- 1 40.0 0.55 0.67 Insect Screen (default) Existing No (2) 2680 Fr.Dr. [E) 2 RUE (E) ---- ---- 1 40.0 j 0.55 0.67 Insect Screen (default) Existing No 2680 Fr.Dr. (E] Ri/E (E) ---- ---- 1 20.0 0.55 0.67 Insect Screen (default) Existing No 4030 Wdw [E]r RUE (E) ---- ---- 1 12.0 0.71 0.73 Insect Screen (default) Existing No (2) 2670 Fr.Dr. [E] RUE (E) ---- ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No . 26310 Wdw [E] RUE (E) ---- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 30310 Wdw [E] RUE (E) ---- ---- 1 11.5 0.71 0.73 Insect Screen (default) Existing No 3036 Wdw [E] RUE (E) ---- ---- 1 10.5 0.71 0.73 Insect Screen (default) Existing No 2050 Wdw [E] RUE (E) ---- --- 1 10.0 0.71 0.73 Insect Screen (default) Existing No 3050 Wdw [E] Re/N (E) ---- ---- 1 15.0 0.71 0.73 Insect Screen (default) Existing No (2) 2670 Fr.Dr. [E] 2 Re/N (E) ---- ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No 26310 Wdw [E] 2 Re/N (E) ---- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 26310 Wdw [E] 3 Re/N (E) ---- ---- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 34410 Wdw [E] Re/N (E), ---- ---- 1 16.1 0.71 0.73 Insect Screen (default) Existing No 34410 Wdw [E] 2 Re/N (E) -- --- 1 16.1 0.71 0.73 Insect Screen (default). Existing No 46210 Wdw [E] Re/N (E) ---- - 1 11.3 0.71 0.73 Insect Screen (default) Existing No 40410 Wdw [E] Re/N (E) ---- --- 1 19.3 0.71 0.73 Insect Screen (default) Existing No 46410 Wdw [E] Re/N (E) -- --- 1 22.2 0.71 0.73 - Insect Screen (default) Existing No 40410 Wdw [E] 2 Re/N (E) ---- ---- 1 19.3 0.71 0.73 Insect Screen (default) Existing No (2) 2670 Fr.Dr. (E) 3 Re/N (E) --- 1 35.0 0.55 0.67 Insect Screen (default) Existing No 26310 Wdw [E] 4 Re/N (E) ---- ---- 1 9.6 0.71 0.73 Insect Screen (default) Existing No . (2) 2670 Fr.Dr. [E] 4 Re/N (E) ---- ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No 110310 Wdw [E] Le/W (E) ---- 1 7.0 0.71 0.73 Insect Screen (default) Existing No 110310 Wdw [E] 2 Le/W (E) ---- ---- 1 7.0 0.71 0.73 Insect Screen (default) Existing No 34410 Wdw [E] 3 Le/W (E) ---- ---- 1 16.1 0.71 0.73 Insect Screen (default) Existing No (2) 2670 Fr.Dr. [E] 5 Le/W (E) ---- ---- 1 35.0 0.55 0.67 Insect Screen (default) Existing No 34410 Wdw [E] 4 Le/W (E) ---- ---- 1 16.1 0.71 0.73 Insect Screen (default) Existing No 3070 Fr.Dr. [E] Le/W (E) ---- ---- 1 21.0 0.55 0.67 Insect Screen (default) Existing No 16410 Wdw [E] Le/W (E) ---- ---- 1 7.2 0.71 0.73 Insect Screen (default) Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-16 05:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml CF1R-PRF-01 Page 6 of 10 50410 Wdw [E] Le/W (E) -- --- 1 24.2 0.71 0.73 Insect Screen (default) Existing No 16410 Wdw [EJ 2 Le/W (E) -- --- 1 7.2 0.71 0.73 Insect Screen (default) Existing No 3016 Wdw [E] Le/W (E) -- --- 1 4.5 0.71 0.73 Insect Screen (default) Existing No 3016 Wdw [E] 2 Le/W (E) -- --- 1 4.5 0.71 0.73 Insect Screen (default) Existing No (2) 2680 Fr.Dr. [E] 3 Le/W (E) -- --- 1 40.0 0.55 0.67 Insect Screen (default) Existing No (2) 2680 Fr.Dr. [E] 4 Le/W (E) -- --- 1 40.0 0.55 0.67 Insect Screen (default) Existing No (2) 2680 Fr.Dr. [E] 5 Le/W (E) -- --- 1 40.0 0.55 0.67 Insect Screen (default)' Existing No (2) 2680 Fr.Dr. [E] 6 Le/W (E) -- --- 1 40.0 0.55 0.67 Insect Screen (default) Existing No 46410 Wdw (E) 2 Fr/S -- --- 1 22.2 0.71 0.73 Insect Screen (default) Existing No 40410 Wdw [E] 3 Fr/S -- --- 1 19.3 0.71 0.73 Insect Screen (default) Existing No (2) 2680 Fr.Dr. [E] 7 Fr/S -- --- 1 40.0 0.55 0.67 Insect Screen (default) Existing No 2.5' Half Circle Wdw [E] Fr/S -- --- 1 2.5 0.71 0.73 Insect Screen (default) Existing No (B) 4050 Wdw [New) Fr/S 2 -- --- 1 20.0 0.51 0.26 Insect Screen (default) New N/A 26310 Wdw (E] 5 RUE (E) 2 -- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 26310 Wdw [E] 6 Ri/E (E) 2 -- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 26310 Wdw [E] 7 Re/N (E) 2 -- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No 26310 Wdw [E] 8 Re/N (E) 2 -- --- 1 9.6 0.71 0.73 Insect Screen (default) Existing No (2) 2670 Fr.Dr. [E] 6 Re/N (E) 2 -- --- 1 35.0 0.55 0.67 Insect Screen (default) Existing No 30310 Wdw [E] 2 Le/W (E) 2 -- --- 1 11.5 0.71 0.73 Insect Screen (default) Existing No 30310 Wdw [E] 3 Le/W (E) 2 -- --- 1 11.5 0.71 0.73 Insect Screen (default) Existing No 2030 Wdw [E] Le/W (E) 2 -- --- 1 6.0 0.71 0.73 Insect Screen (default) Existing No (2) 3080 Fr.Dr. [New] RUE -- --- 1 48.0 0.37 0.17 Insect Screen (default) New N/A (2) 3080 Fr.Dr. [New] 2 RUE -- --- 1 48.0 0.37 0.17 Insect Screen (default) New N/A (A) 5040 Wdw [New] Le/W 2 -- --- 1 20:0 0.51 0.26 Insect Screen (default) New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition 4080 Re/N (E) 32.0 0.50 Existing No 40802 Fr/S 32.0 0.50 Existing No 40803 Fr/S 32.0 0.50 j Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-16 05:57:36 - CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Description: Title 24 Analysis Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xmi CF1 R -PRF -01 Page 7 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total Cavity R -value Assembly Layers Zone Area (ft2) 2x4 Top Chord of Roof Edge Insul. R -value Cavity/Frame: no insul. /2x4 Top Chrd Attic Roof Cons Attic Roofs Truss @ 24 in. O.C. - no insulation - Roof Deck: Wood Siding/sheathing/decking 4198 0.1 - none - 0.8 • Roofing: Light Roof (Asphalt Shingle) Existing No Slab -on -Grade 2 Bath-Add'n • Inside Finish: Gypsum Board R-21 Wall Exterior Walls 2x6 @ 16 in. O.C. R 21 Cavity/Frame: R-211 W No Slab -on -Grade 3 Guest 563 • Exterior Finish: Wood Siding/sheathing/decking - none - 0.8 No Existing • Inside Finish: Gypsum Board R-30 Roof Attic Ceilings (below attic) 2x4 @ 24 in. O.C. R 30 Cavity/Frame: R-9.1 /2x4 0 No New No • Over Floor Joists: R-20.9insul. • Inside Finish: Gypsum Board R-38 Roof Attic Ceilings (below attic) 2x4 @ 16 in. O.C. R38 Cavity/ Frame: R-9.1 /2x4 • Over Floor Joists: R-28.9insut SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing . Condition Slab -on -Grade Main House 4198 0.1 - none - 0.8 No Existing No Slab -on -Grade 2 Bath-Add'n 150 0.1 - none - 0 No New No Slab -on -Grade 3 Guest 563 0.1 - none - 0.8 No Existing No Slab -on -Grade 4 Seating Area-Add'n 221 0.1 - none - 0 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 60 Pa Not Required Not Required Not Required -- Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-1605:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml C F1 R -PRF -01 Page 8 of 10 WATER HEATING SYSTEMS 01 02 03 01 02 D3 04 05 06 Name ' Distribution Type Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 Standard 1 Annual Existing No DHW Sys 1 Standard 2 Annual Existing No DHW Sys 1 Standard 3 Annual Existing No WATER HEATERS 01 02 03 04 01 01 02 03 04 06 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 DHW Heater 1 Natural Gas Small Storage 5D 0.575 EF 40000-Btu/hr 0 0 DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 :d WATER HEATING - HERS VERIFICATION 01 02 03 04 01 02 03 04 06 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a DHW Sys 1 n/a n/a n/a In/a Name Ducted n/a n/a DHW Sys 1 n/a n/a n/a In/a HVAC System - In/a In/a HVAC SYSTEMS 01 02 03 04 06 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC System - Other.Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 4348 Existing No Main Housel Cooling System Component 1 Component 1 System 1 1 HVAC System2 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 784 Existing No Cooling System Component 2 Component 2 System 2 2 Registration Number:" Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11.16 05:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MR. STERIN Calculation Description: Title 24 Analysis C F1 R -PRF -01 Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Page 9 of 10 Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml HVAC - HEATING SYSTEMS 01 02 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 78 AFUE HVAC -COOLING SYSTEMS 01 02 03 04 06 06 07 04 06 Efficiency 07 Multi -speed 09 Name System Type • EER SEER Zonally Controlled Compressor HERS Verification Cooling Component '1 SplitAirCond - Split air conditioning 8.488 9.7 No No N/A Duct Leakage system Location Location Bypass Duct Status Condition Cooling Component 2 SplitAirCond - Split air conditioning 8.488 9.7 No No N/A None system No N/A System 1 specified) HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 06 06 07 O9 09 09 Insulation Supply Duct Return Duct Verify Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 6 Attic Attic None Existing No N/A System 1 specified) Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 2 specified) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency.Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-16 05:57:36 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: MR. STERIN Calculation Date/Time: 05:53, Sun, Nov 16, 2014 Page 10 of 10 Calculation Description: Title 24 Analysis Input File Name: 78400 Coyote Canyon Ct. - T24 Corr111614.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 11/16/2014 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 City/StateZip: a Quinta, Ca 92247 Phone: 760.485.8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Eduardo Escobar Company: Date Signed: ESCOBAR DESIGN Address: License: 43927 Pacific Ave. City/State/Zip: Phone: Indio, Ca 92201 (760) 289-9221 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-16 05:57:36 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name MR. HENRIK STERN Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11111612014 Date Project Address 78400 Coyote Canyon Ct. - APN. 770-240 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,132 Addition 371 # of Units 1 INSULATION Construction Type Area Cavi (ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 4,761 Perim = 0' Existing Wall Wood Framed R 21 3,678 Existing Door Opaque Door - no insulation 96 Existing Demising Wood Framed R 19 932 Existing Roof Wood Framed Attic R30 4,761 Existing Demising Wood Framed R 13 116 Existing Slab Unheated Slab -on -Grade - no insulation 371 Perim = 0' New Wall Wood Framed R 21 213 Altered FENESTRATION Orientation Area(ft) I Total Area: 1.074 Glazing Percentage: 20.9 % U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor. 0.59 Exterior Shades Status Right (E) 135.0 0.550 0.67 none none Bug Screen Existing Right (E) 72.8 0.710 0.73 none none Bug Screen Existing Rear (N) 167.3 0.710 0.73 none none Bug Screen Existing Rear (N) 140.0 0.550 0.67 none none Bug Screen Existing Left (Kq 122.8 0.710 0.73 none none Bug Screen Existing Left (W) 216.0 0.550 0.67 none none Bug Screen Existing Front (S) 44.0 0.710 0.73 none none Bug Screen Existing Front (S) 40.0 0.550 0.67 none none Bug Screen Existing Front (S) 20.0 0.510 0.26 none none Bug Screen New Right (E) 96.0 0.370 0.17 none none Bug Screen New Left (lN) 20.0 0.510 0.26 none none Bug Screen New HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC System - Main Hous Ducted Ducted Attic 6.0 Existing HVAC System Ducted Ducted Attic 4.2 Existing WATER HEATING Type Gallons Min. Eff Distribution Status Ener Pro 6.3 by Ener Soft User Number. 5732 RunCode: 2014-11-16T05:59:30 ID: LQ 102614Con11161- Pae 13 of 19 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name MR. HENRIK STERIN Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 111116)2014 Date Project Address 78400 Coyote Canyon Ct. - APN. 770-240 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1 5,132 Addition 371 # of Units 1 INSULATION Area Construction Type Cavi (ft) Special Features Status Roof Wood Framed Attic R38 371 New Wall Wood Framed R 21 174 New FENESTRATION Total Area: 1.074 Glazi Percentage: 20.9 % New/Altered Average U-Factor. 0.59 Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Type Gallons Min. Eff Distribution Status Ener Pro 6.3 by Ener Soft User Number. 5732 RunCode: 2014-11-16705:59:30 ID: LQ102614Con-11161� Pae 14 of 19 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -IR Project Name Date MR. HENRIK STERIN 11/16/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U -factor. 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is exempt from the maximum U -factor requirement 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number. 5732 Q LQ 102614Con-11161- Page 15 of 19 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date MR. HENRIK STERIN 11/16/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.00)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)l : Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btulhr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off- eak'electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as -high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. 150.0 k 1 C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)l E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 byEnergySoR User Number. 5732 ID: LQ102614Corr11161z Page 16 of 19 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name Date MR. HENRIK STERIN 711/16/2014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of 150.0 k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts for dwelling units larger than 2,500 ft' may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130. 1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of in rens and egress. EnergyPro 6.3 by EnergySoff User Number. 5732 M: LQ 102614Con-11161, Page 17 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. HENRIK STERIN Date 11/16/2014 System Name HVAC System - Main House Floor Area 4,348 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 4,445 Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible 85,156 0 5,811 0 0 0 5,811 1 96,779 COIL HTG. Latent CFM 5,212 1,239 0 0 57212 PEAK Heating System Sensible Output perSystem 0 47,239 Total Output Btuh 0 Output (Btuh/ ) 0.0 2,725 Cooling System 0 Output per System 1 0 Total Output Btuh 3 0 Total Output (rons) 0.0 2,725 Total Output Btuh/s 0.0 Total output s on 17,392,000.0 1 52,688 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow (cfm) 0 Default FAlJ/AC 1992 - 2005 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3 3 0 0 0 0 Aug 3 PM Jan 1 AM Airflow (cfm/ ) 0.00 Airflow cfmfTon 0.0 Outside Air %) 0.0% Outside Air cfm/s 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar 0 cfm 67 OF 67 OF 105 OF Heating Coil r 104 OF ROOM 68 °F COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside AirAr 0 cfm 77/63°F 4I 77/63°F 55/54°F - Cooling Coil 48.7% 57 / 55 OF I ROOM 75/62°F EnergyPro 6.3 by EnergySoft User Number. 5732 RunCode: 2014-11-16705:59:30 ID: LQ102614Con11161i Page 18 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name MR. HENRIK STERIN Date 11/16/2014 System Name HVAC System Floor Area 784 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible. Total Room Loads 804 15,392 Return Vented Lighting 0 Return Air Ducts 1,305 Return Fan 0 Ventilation o 0 Supply Fan 0 Supply Air Ducts 1,305 TOTAL SYSTEM LOAD 18,003 COIL HTG. Latent CFM 940 259 0 0. 940 PEAK Heating System Sensible Output per System 0 9,741 Total Output Btuh 0 Output (Btu h/ ) 0.0 692 Cooling System 0 Output r System 1 o Total Output Btuh 1 0 Total Output (Tons) 0.0 692 Total Output Btuh/s 0.0 Total Output on 9,408,000.0 11,125 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow (cfm) 0 Default FAU/AC 1992 - 2005 1 Total Adjusted System Output 1 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 0 0 0 0 Aug 3 PM Jan 1 AM Airflow (cfm/ 0.00 Airflow cfm/Ton 0.0 Outside Air (%) 0.0 °,6 Outside Air cfm/s 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 dm 66 °F 66 OF 105 OF Heating Coil 103 OF ROOM 11 68 °F COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 77/63°F 55/54°F Outside Air Ar 0 cfm Cooling Coil 48.7% ° t T Ibk A BUILDING & SAFETY DEPT. 57 / 55 OF I ROOM In 75/62°F I ergyPro erPJ se Nu, ber. 5738R RunCode: 2014-11-1 6 705:59:30 ID: LQ102614Con-11161z Page 19 of 19 FOR CONSTRUCTION DATE BY