Loading...
9908-027 (RR)U) I— (V U) W O =) M t` C ' W C:) Z � O O JUc�o ~a W Z M u) (\I ON 0 °) CL Q `rQCr0 XW0 _J � mQU C rn H Z_ ab 5)/-y V Q J LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Date Signature of Contractor OWNER -BUILDER DECLARATION I he affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by ection 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection p rpo'se s. 9 Signature (Owner/Agent, ia° -'Date / BUILDING PERMIT PERMIT# - 994* -02; DATE (bf 7VALUATION it�i{�. LOT TRACT JOB SITE S 78-095 �;�.?,�3.A.3l��'�YiZ�1N ADDRESS APN _ — OWNER CONTRACTOR/DESIGNER/ENGINEER ♦ x:a ♦�.�.ra K 01 p�W10%O?: f3 ��rl �.... R01111DR. . 7? -095 C:OKONADO LA QUMW CA 9:1253 USE OF PERMIT 0l"I4Ea'Z..AL BOILING .sxr•�%C� � 's,l'itlii.�iC is 4J'(.M)a,Y.t g.6 4'.Qi Rasj•fy i.! %'i �oFJt1'U`.el� jti�i.(::x.7.E f"lila 1Ui-1�fit)^i1;S-i3t]U yi��tl.!}Il `OM ANY)pi,AyN r'tECK( (,( LESS, 1}LSI '��i�� � C'i :i S S01.00 "MfM., PEKi4UT FEES +t3), NOW RECEIPT 2, , -�'- DATE C BY 1A1114d DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck ` Exhaust Fans O.K. to Wrap �—"� F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wail Insulation Condensate Lines Party Wali Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS -SPAS Steel Set Hacks Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Pibg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL'APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: ,._.: �; 78 - o s Got ►A dos CAE' • y«* 1 � 9 � � ER -2469 ,S REPORTT"' Reissued July 1, 2001 ICBO Evaluation Service, Inc. • 5360 Workman Mill Road, Whittier, California 90601 • www.icboes.org Filing Category: SKYLIGHTS AND SMOKE VENTS (232) BRISTOLITE SKYLIGHTS BRISTOL FIBERLITE INDUSTRIES, dba BRISTOLITE SKYLIGHTS 401 EAST GOETZ AVENUE POST OFFICE BOX 2515 SANTA ANA, CALIFORNIA 92707 1.0 SUBJECT Bristolit Sk li hts. 2.0 DESCRIPTION 2.1 General: Bristolite Skylights are skylights with glazing of approved plastic materials formed to a dome shape. Figur 1 and Tables 1 through 5 contain further information. All series are available in both curb -mounted and self -flashing models. See Table 1 for general description of the skylight models. 2.1.1 S Series: The S series uses 0.125 -inch -thick (3.2 mm), one-piece fiberglass domes fabricated in 3 -ounce (85 gram) fiberglass roving impregnated with polyester resin and classi- fied as CC1 plastic. The self -flashing version is mounted to a 4 -inch -high (102 mm) frame with 23/4 -inch -wide (70 mm) mounting flange formed from 6063-T5 aluminum. The dome edge is covered by a continuous, No. 26 gage [0.019 inch (0.48 mm)], galvanized steel angle. See Table 3 for additional description. 2.1.2 AS Series: The AS Therm -o -weld series uses acrylic plastic domes, classified as CC2 plastic and recognized in Evaluation Report ER -2576. These domes are chemically fused to a fiberglass frame consisting of 3 ounces (85 grams) of fiberglass roving impregnated with polyester resin and classified as CC1 plastic. The self -flashing version is mounted to a 4 -inch -high (102 mm) frame with a 23/4 -inch - wide (70 mm) mounting flange formed from 6063-T5 aluminum. See Tables 2 and 5 for additional description. 2.1.3 AL Series: The AL Alumi-lite series uses acrylic plastic domes, classified as CC2 plastic and recognized in Evalua- tion Report ER -2576. These domes are attached at the fac- tory to a retaining frame fabricated from 60,63 T5 aluminum. The self -flashing version is mounted to a 4 -inch -high (102 mm) frame with a 23/4 -inch -wide (70 mm) mounting flange formed from 6063-T5 aluminum. See Tables 2 and 5 for addi- tional information. 2.2 Installation: 2.2.1 Curb -mounted Units: The curb is minimum 2 -by -6 lumber, sized to the inside dimensions described in Table 2. This curb must allow the plastic dome edge to be at least 4 inches (102 mm) above the roof plane. The roof covering is then removed. The opening is cut into the roof, and damage to rafters must be avoided. The curb is mounted to the roof deck to the satisfaction of the building official. No. 26 gage (0.48 mm) corrosion -resistant metal flashing, 14 inches (356 mm) wide, is bent into an "L" shape with a 31/2 -inch (89 mm) vertical leg. Flashing is 5 to 6 inches (127 to 152 mm) wider than the opening. The leg is cut at the curb width, with the end tabs bent flat. These pieces are placed under shingles at the high end of the openings. A second flashing piece is prepared similarly, except the ends are cut and bent to wrap around the curb. The two pieces are coated on faying surfaces with mastic and bonded together. The sides of the opening are flashed with 12 -inch -wide (305 mm), L-shaped pieces lapped 3 inches (76 mm) under the previous piece and under the shingles. A bottom piece of flashing is placed. Each flashing piece is nailed to the curb at the joint. A continuous caulking bead is placed on top of the curb. The skylight is set on top of the curb and positioned to allow a 1/4 -inch (6.4 mm) gap between the unit and the side of the curb. The unit is then nailed to the curb according to Table 4. Nail heads should be 1/16 inch (1.6 mm) from curb to permit movement. 2.2.2 Self -flashing Units: Self -flashing units must not be installed on a wood shake or wood shingle roof. The opening is cut into the roof and damage to rafters must be avoided. The edges of the opening are framed with nominal 2 -inch - wide (51 mm) lumber. A 4 -to -5 -inch -wide (102 to 127 mm) band of roofing mastic, 1/4 inch (6.4 mm) thick, is applied around the opening. The unit is then set into the mastic and fastened according to Table 4. The flanges are covered on the sides and top with a roof covering. 2.3 Identification: Each skylight is identified by a label bearing the Bristolite Sky- lights name and address, the plastic dome thickness and classification, the evaluation report number (lCBO ES - ER -2469), and a safety label warning of risk of fall. 3.0 EVIDENCE SUBMITTED Data in accordance with the ICBG ES Acceptance Criteria for Plastic Skylights (AC16), dated April 1997, and the ICBG ES Acceptance Criteria forSkylightswith Plastic Frames (AC79), dated April 1994. 4.0 FINDINGS That the Bristolite Skylights as described in this report comply with the 1997 Uniform Building CodeTMm, subject to the following conditions: 4.1 Skylights are installed in accordance with this report, manufacturer's instructions and Section 2603.7 of the code. 4.2 The maximum roof live load is 20 pounds per square foot (958 Pa). 4.3 The maximum roof wind -uplift load is 13 pounds per square foot (622 Pa). 4.4 The AS series is installed only where nonrated roof coverings are permitted. This report is subject to re-examination in two years. REPORTS— are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICBG Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2001 �vee� Page 1 of 5 ' , Paoe 2 of 5 TABLE 1 -GLOSSARY OF MODEL TYPES ER -2469 MODELTYPE DESCRIPTION CURB MOUNTED SELF FLASHING ALUM. RETAINER CAP CCI FIBERGLASS RETAINER SKIRT CC1 ONE-PIECE FIBERGLASS DOME CC2 ACRYLIC DOME OR PURAMID S -CM CCI FIBERGLASS DOME X 141/4 x 14 1/4 0.125 X X X S -SF CCI FIBERGLASS DOME 19 x 19 X 5 X X AS -CM THERM -0 -WELD ACRYLIC DOME X 5 3030 X X SF AL- THERM -2 -WELD ACRYLIC DOME I -LITE ACRYLIC DOME UM - X. 3737 X X X ACS -CM THERM -O -WELD ACRYLIC CIRCULAR X x X 42 x X ACS -SF THERM -0 -WELD ACRYLIC CIRCULAR X X X X 0.125 X TABLE 2-BRISTOLITE ACRYLIC SKYLIGHTS INSIDE CURB OPENING -DOME THICKNESS -DOME RISE TYPES: AS -CM, AS -SF, AL -CII AL -SF, ACS -CM, ACS -SF MODEL SIZE (Nominal) AS -CM, AS -SF ACS -CM, ACS -SF ALCM, AL -SF INSIDE CURB DIMENSION (Inches) DOME THICKNESS (Inch) DOME RISE (Inches) 1414 X X 141/4 x 14 1/4 0.125 5 1919 X X 19 x 19 0.125 5 2222 X X 221/4 x 221/4 0.125 5 3030 X X 301/4x 301/4 0.125 5 3737 X X 37 x 37 0.125 5 4242 x 42 x 4646 X X 461/4 x 461/4 0.125 5 4848 X X 48 x 48 0.150 5 5555 X X 55 x 55 0.187 6 7070 X X 701/4 x 701/4 0.250 7 7575 X X 75 x 75 0.250 8 8484 X X 84 x 84 0.250 9 9292 X X 921/2 x 921/2 0.250 10 2230 X X 221/4 x 301/4 0.125 5 1422 X X 141/4 x 221/4 0.125 5 1446 X X 141/4 x 461/4 0.125 5 2237 X X 221/4 x 37 0.125 5 2246 X X 221/4 x 461/4 0.125 5 2272 X X 221/4 x 72 0.125 8 2296 X X 221/4 x 96 0.125 10 3037 X X 301/4 x 37 0.125 5 3046 X X 301/4 x 461/4 0.125 5 3069 X X 301/4 x 691/2 0.125 7 3096 X X 301/4 x 96 0.125 10 3496 X X 34 x 96 0.150 10 36120 X X 36 x 120 0.250 12 3746 X X 37 x 461/4 0.125 5 3775 X X 37 x 75 0.150 8 3859 X X 38 x 59 0.150 6 4669 X X 461/4 x 691/2 0.150 7 4689 X X 461/4 x 891/2 0.150 9 4896 X X 48 x 96 0.150 10 48120 X X 48 x 120 0.250 12 5460 X X 54 x 60 0.187 6 6096 X X 60 x 96 0.187 10 24 dia X 24 0.125 5 31 dia X 31 0.125 5 43 dia X 43 0.125 5 54 dia X 54 0.187 6 67 dia X 67 0.187 7 91 dia X 91 0.250 9 For SI: l inch = 25.4 mm. I. ' ;Page 3 of 5 ER -2469 TABLE 3—BRISTOLITE FIBERGLASS SKYLIGHTS INSIDE CURB OPENING—DOME THICKNESS—DOME RISE TYPES: S -CM, SSF MODEL SIZE (Nominal) STA. PROD. LINES S -CM, S -SF INSIDE CURB DIMENSION (Inches) DOME THICKNESS (Inch) DOME RISE (Inches) 1414 X 141/4 x 141/4 0.125 5 2222 X 221/4 x 221/4 0.125 5 1422 X 141/4 x 221/4 0.125 5 2246 X 221/4 x 461/4 0.125 5 2272 X 221/4 x 72 0.125 7 2246 X 221/4 x 96 0.125 10 3037 X 301/4 x 37 0.125 5 4896 X 48 x 96 0.125 10 For SI: 1 inch = 25.4 mm. TABLE 4—MINIMUM NUMBER OF SKYLIGHT ATTACHMENT FASTENERS MODEL SIZE (Nominal I.D.) CURB -MOUNTED ALCM, AS -CM, ACS -CMI SELF -FLASHING SSF, AS -SF, AL -SF, ACS4F2 1414 12 8 1919 12 8 2222 16 8 3030 20 8 3737 24 12 4646 28 12 4848 28 16 5555 32 16 7070 40 20 7575 44 20 8484 44 24 9292 48 28 1422 14 8 1446 20 10 2237 20 10 2246 22 10 2272 28 14 2296 34 18 3037 22 10 3046 24 10 3069 30 14 3096 36 18 3496 36 18 36120 44 26 3746 26 12 3775 32 16 3859 30 14 4669 34 16 3689 40 20 4896 40 22 48120 44 28 5460 40 16 6096 42 22 24 dia. 9 8 31 dia. 9 8 43 dia. 9 12 54 dia. 9 16 67 dia. 9 16 91 dia. 21 28 For SI: 1 inch = 25.4 mm. lFasteners are 6d corrosion -resistant common nails. 2Fasteners are 16d corrosion -resistant common nails. TABLE 5—MINIMUM NUMBER OF DOME RETAINER FRAME FASTENERS MODEL SIZE (Nominal I.D.) ALSF1 AS -SF, SSF, ACS -SF 1414 4 Chemically Fused 1919 4 2222 8 3030 8 737 12 12 4848 12 5555 16 7070 16 7575 16 8484 20 9292 20 1422 6 1446 8 2237 8 2246 8 2272 10 2296 12 3037 10 3046 10 3069 12 3096 14 3496 16 36120 20 3746 12 3775 14 3859 14 4669 14 4689 16 4896 16 48120 20 5460 16 6096 18 24 dia. n/a 31 dia. n/a 43 dia. n/a 54 dia. n/a 67 dia. n/a 91 dia. n/a For SI: 1 inch = 25.4 mm. INo. 8 stainless steel screws RBERGLASS DOME ALUM. TF' FRAME - ANCHOR BY OTHERS\ THERM -O -Kw, ROORNG BY OTHERS' ACRYLIC DOME 7HERM-O-WELD' FRAME 1/8' STL, POP RIVETS @� ANCHOR 16'o.c..MAX. ROOFING <. 'BY OTHERS 2X Q 1/2') WIDE WOOD CURB BY OTHERS ROUGH OPENING MODEL S -CM ROUGH OPENING MODEL : S -SF CURB SEALANT BY OTHERS 2X (1 1/27 WIDE WOOD CURB BY OTHERS ROUGH OPENING MODEL : AS -CM GASKET ROORNG BY OTHERS ROUGH OPENING ANCHOR -MODEL: AS -SF FIGURE 1 SEALANT BY OTHERS LA TE PROVISION FASTENER CONTINUOUS NO. 26 GAGE GALVANIZED STEEL ANGLE WORNG BY OTHERS DOME ANCHOR PROVISION 1. BRACKET L %F' FRAME Page 5 of 5 ACRYLIC ALUM, PERIMETER C4P-, BY ACRYLIC ALUM. PERIMETER C4P-, PRENE GASKET 1/27 WIDE Wt7OO BY OTHERS ROUGH OPDVINC MODEL : AL -CM REN£ G4SKET SF' fRAME ROUGH OPDVNG MODEL : AL -SF FIGURE 1—(Continued) ER -2469 PROW9SION - CAP FASTENER UM. CM' FRAM£ TE PROWSION iW FASTEND? . 7 8.095 GoI-oNODOS GA . RIYORIC Heating and Air Conditioning TECHNICAL GUIDE 80 AFUE MULTI -POSITION GAS-FIRED FURNACES 32-104 MBH OUTPUT HIGH -EFFICIENCY INDUCED COMBUSTION MODELS: P4HU 1cpEFFICIENCY RATING CERTIFIED amal pE51({�y � SA eeenneo 036-21047-001 Rev. A DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for instal- lation in upflow or horizontal applications. These furnaces are designed for residential installation in a base- ment, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All -units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code. WARRANTY 20 -year limited warranty on the heat exchanger. 10 year heat exchanger warranty on commercial applications. ,5 -year limited parts warranty. FEATURES • Easily applied in upflow, horizontal left or horizontal right installation with no conversion necessary • 100% shut off main gas valve for added safety • Rollout safety control • Low unit amp requirement for easy application • High quality inducer motor for quiet operation • Built-in self diagnostics with fault code display • "Diamond Tough" m hot surface igniter • High velocity filter provided for field installation • Standard terminals for controlling humidifiers and EAC's • 40 VA control transformer fuse protected • Easy to connect power and control wiring • Efficiency ratings of 80 AFUE attained by using tubular heat exchangers • Cooling relay supplied for easy installation of add-on cooling • Multi -speed PSC, direct -drive blower motors to match cooling requirements • Adjustable fan -off settings to eliminate "cold -blow" • Compact 40 -in height allows installation in small space confines • Lo NOx models have been designed to meet specific code requirements. Lo NOx units may not be converted to propane. 036-21047-001 Rev. A (4/00) YORK E I+ D 3/4 necdon) 0 0 o POWER WIRING 13-W4 1M. Wni F GASINLEr 1-1/4'X2-1/7 OPTIMAL SIDE _ (ErTHEER SIDE) LR II AW w28 1 /2►t FRONT LEFT SIDE "*- B ---P4 fi28 1/2 2p �Omrod� SREMOVED) (� D) 2 �- E -►M TOP IMAGE BOTTOM IMAGE 3/4• (FRO" (FRO" FLANGE All dimensions are in inches, and are approximate. RATINGS & PHYSICAL / ELECTRICAL DATA ACCESS WIRING 7/S' K.O. ® Sg 14-3/4 a� 2 frIF---� I1 32-1/2 ® I 14 8 ED rSTAT WIRING 7/8' KO. RIGHT SIDE "L" in model number indicates Lo NOx unit K "L" in model designator indicates factory built to Nox units. t. AFUE numbers are determined in accordance with DOE test procedures. $. Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition) • For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. • Wire size based on copper conductors, 60°C, 3% voltage drop. • Continuous return air temperature must not be below 55"F. Unitary Products Group BLOWER MIN. WIRE AIR MAX TOTAL MAX OVER- SIZE OPER. MODEL INPUT OUTPUT AFUEt TEMP OUTLET UNIT CURRENT (AWG) @ WGT. MBH MBH RISE 'F TEMP "F HP AMPS SIZE AMPS PROTECT.$ 75 FT. ONE (LBS) WAY P4HUA12N03201 40 32 80.0 25 - 55 155 1/3 6.2 10 x 7 9.0 20 14 105 4HU 01 60 80.0 25-55 155 3 6.2 10 x 7 9.0 20 14 110 4HUA12NO6401 8 64 0.0 1 3 6.2 10 x .0 4 lit HU 06401 80 (A '2555 4 .5 11 x8 12.0 2 14 Izo P4HUC20N0640 80, 0 55 165 1 12.2 11 x10- 14.0 12 P4HUB12N08001 100 80 80.0 40-70 170 112 7.0 10 x 8 12.0 20 14 128 P4HUB16N08001 100 80 80.0 35-65 165 1/2 10.4 10 x 10 12.0 20 14 134 P4HUC20N08001 100 80 80.0 25-55 155 1 12.2 11 x 10 14.0 20 12 145 P4HUC16N09201 115 92 80.0 35-65 170 1/2 10.4 10 x 10 12.0 20 14 145 P4HUC20N09201 115 92 80.0 30-60 170 1 _ 12.2 11 x 10 14.0 20 12 147 P4HUD20N10401 130 104 80.0 35-65 165 1 12.2 11 x 10 14.0 20 12 158 K "L" in model designator indicates factory built to Nox units. t. AFUE numbers are determined in accordance with DOE test procedures. $. Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition) • For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. • Wire size based on copper conductors, 60°C, 3% voltage drop. • Continuous return air temperature must not be below 55"F. Unitary Products Group YORK 036-21047-001 Rev. A (4/00) BLOWER PERFORMANCE CFM - UPFLOW/HORIZONTAL (WITHOUT FILTER) Note: Data below reflects airflows with single return opening, either left or right side or bottom MODELS P•HU/G8T-UH/ L8T-UH* SPEED TAP 0.10 0.20 EXTERNAL 0.30 0.40 STATIC PRESSURE, INCHES W.C. 0.50 0.60 0.70 0.80 0.90 1.00 40 / 32 / 1200 / "A"t 60 / 48 / 1200 /"A"t 80/64/1200/"A" MED -HIGH 1110 1100 1075 1060 1030 980 920 835 680 520 MED -LOW 845 840 830 815 790 750 670 595 480 320 LOW 675 665 660 645 620 585 530 455 360 255 100 / 80 / 1200 / "B" HIGH 1675 1645 1595 1530 1465 1385 1280 1155 1025 810 MED 1270 1260 1250 1240 1215 1185 1125 1035 910 695 LOW 955 950 945 935 920 905 865 810 685 510 80 / 64 / 1600 / "B"t HIGH 1970 1935 1900 1850 1795 1735 1660 1590 1495 1395 MED 1445 1435 1425 1415 1405 1375 1350 1300 1240 1160 LOW 1245 1235 1225 1215 1205 1190 1170 1135 1090 995 100 / 80 / 1600 / "B"t HIGH 2050 1990 .1935 1860 1770 1680 1580 1490 1370 1255 MED 1630 1615 1600 1585 1550 1510 1445 1355 1270 1135 LOW 1340 1325 1310 1295 1285 1270 1245 1195 1125 1005 115/92/1600/"C" HIGH 2040 1975 1925 1855 1780 1695 1610 1505 1380 1225 MED 1725 1685 1650 1610 1555 1500 1425 1340 1220 1075 LOW 1365 1355 1325 1290 1265 1250 1210 1140 1045 940 80/64/2000/"C". 100/80/2000/"C"t 115 / 92 / 2000 / "C"t HIGH 2400 2320 2275 2200 2115 2025 1930 1825 1700 1570 MED 2050 2025 1980 1930 1855 1805 1720 1635 1530 1400 LOW 1690 1675 1660 1630 1610 1560 1500 1430 1330 1225 130/104/2000/"D"t HIGH 2380 2330 2270 2205 2120 2025 1920 1815 1705 1565 MED 2040 2010 1980 1920 1875 1790 1705 1610 1515 1385 LOW 1690 1680 1655 1630 1590 1530 1490 1425 1350 1235 NOTE: Data below reflects airflows with two return openings - two sides or one side and bottom. 80/64/2000/"C" 100 / 80 / 2000 / "C"t 115 / 92 / 2000 / "C"t HIGH 2405 2340 2275 2210 2130 2050 1955 1840 1725 1600 MED 2005 1990 1965 1935 1880 1815 1725 1635 1535 1410 LOW 1655 1640 1625 1610 , 1585 1540 1485 1420 1340 1235 130 / 104 / 2000 / "D"t HIGH 2385 2335 2275 2195 2120 2040 1935 1820 1700 1555 MED 2005 1980 1955- 1905 1845 1775 1700 1610 1500 1370 LOW 1640 1635 1620 1605 1575 1540 1480 1400 1330 1225 Input / Output / CFM /Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2) NOTES: • Airflow is expressed in standard cubic feet per minute. • Motor voltage at 115V t. Indicates model available in LoNox. Unitary Products Group