05-2693 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tit�144Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 05-00002693 Property Address: 79440 CORPORATE CENTRE DR 114 APN: 649-020-067- -000000- Application description: REMODEL - COMMERCIAL Property Zoning: COMMERCIAL PARK D Application valuation: 75000 r Applicant: Architect or Engineer: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/17/05 Owner: PAUL JAMES R 79440 CORPORATE CTR 102 n2005 LA QUINTA, CA 92253 AUContractor: :ITPLD CONSTRUCTION CO INC Fi653 COMMERCIAL ROAD SUITE 1 PALM SPRINGS, CA 92262 (760)325-8626 Lic. No.: 808132 -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: _B C5 License No.: 808132 5-ate:0� (7 6_-r tractor: f Q" OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file'a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided' for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the bor Code, IIj�shall lfforthwith comply with those provisions. i6ate:Q 7 S pplicam:'r- WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and sta aws relating to building construction, and hereby authorize representatives of this county to enter upon th ove-mentioned prop e for inspection purposes. Date: � % 6 � Si ature (Applicant or Agent): CCAI_L � ,., Application Number . . . . . 05-00002693 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 527.00 Plan Check Fee 342.55 Issue Date . . . . Valuation . . . . 75000 Expiration Date 2/13/06 Qty Unit Charge Per Extension BASE FEE 414.50 25.00 4.5000 ---------------------------------------------------------------------------- THOU BLDG 50,001-100,000 112.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 59.96 Plan Check Fee 14.99 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 2248.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 44.96 Permit MECHANICAL Additional desc . Permit Fee . . . . 37.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 2•.00 4.5000 EA MECH VENT INST/ DUCT ALT 9.00 2.00 6.5000 - ---------------------------------------------------------------------------- EA MECH VENT FAN 13.00 Permit . . . PLUMBING. Additional desc . Permit Fee . . . . 48.00 Plan Check Fee 12.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/13/06 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments COMMERCIAL INTERIOR TENANT IMPROVEMENT. LQPERMIT Application Number . . . . . 05-00002693 ---------------------------------------------------------------------------- Special Notes and Comments 2248 SQ.FT. "B" OCCUPANCY, 23 OCCUPANTS TYPE V -N CONSTRUCTION, 2001 CODES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 34.26 ENERGY REVIEW FEE 34.26 Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 671.96 -------------------- .00 ---------- .00 671.96 Plan Check Total 375.54 .00 .00 375.54 Other Fee Total 68.52 .00 .00. 68.52 Grand Total 1116.02 .00 .00 1116.02 LQPERMIT Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of. Bannin ee Beaumont O Calimesa Canyon Lake 0 Coachella eo Desert Not Springs eo Indian Wells eo Indio eo Lake Elsinore oe La Quints e0 Moreno Valley ee Palm Desert Paris O Rancho Mirage eo San Jacinto ee Temecula Board of Supervisors Bob Buster, District 1 Jahn Tays&one, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 June 27, 2005 RIVERSIDE COUNTY FIRE DEPARTMENT 82-675 y Fax (760) 863-1012 Palm Springs Design Group 4511 E. Sunny Dunes, Ste. E Palm Springs, CA 92264 Re: Non -Structural Building TA.Plan_Review LAQ-05-TI-057179440 Corporate Center Dr., Ste 1143 Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project.- Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. 1) Fire Department approval is based upon the 2001 CBC requirements for Group B occupancies. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy per Sec. 307 of the 2001 CBC. 2) Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire Department for review, along with a plan/inspection fee. The approved plans, with Fire Department Job card must be at the job site for all inspections. 3) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have a durable and legible tag affixed for identification of the correlating tenant space. 4) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact certified extinguisher company for proper placement of equipment. 5) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6' in height. All addressing must be legible and of a contrasting color with the background. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Cc: City of La Quinta — Building Dept WOW or u. noA.mo Sincerely, FRANK KAWASAKI Chief Fire Department Planner By Walter Brandes Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82675 Highway 111, 2"d FL, Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning Beaumont Calimesa 4r Canyon Lake Coachella Desert Hot Springs d Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris 6 Rancho Mirage San Jacinto O Temecula Board of Supervisors Bob Buster, District -I... John Tavaglione, District 2 Jeff stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT 210 West San Jacinto Avenue . Perris, California 92570 . (951) 940-6900 . Fax (951) 940-6910 , v C October 24, 2005 City Of La Quinta .Building Department Re: Gudia Surveying The Riverside County Fire Department is granting a fire and life safety clearance for the following address 9-447 Corp eorat Center &r—Ste--j--1-4-,,'La Quinta. Please call if you should have any questions. ,/ TRACY HOBDAY Battalion Chief / Fire Marshal A4 By Terry Soucy Fire stems Inspectors Temporary Certificate of Occupancy O� p , COPY Imncw. G� 9w5 Building & Safety Department OF This Certificate is issued pursuant to the requirements of Section 109 of the California Building 4 . Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-440 Corporate Ctr Dr. Ste 114 } Use classification: Commercial "Office" TI Building Permit No.: "(Permit numberl" Occupancy Group: B Type of Construction: VN Sprinkled Land Use Zone: CR 30 Day Temporary Certificate of Occupancy, see correction list attached. Owner of Building: James Paul Address: 79440 Corporate Ctr Dr Ste 102 City, ST, ZIP: La Quinta, CA 92253 By: Daniel P. Crawford Jr. Date: Expires 11/26/05 Building Official POST IN A CONSPICUOUS PLACE TITLE 24 REPORT . Title 24 Report for: Guida Surveying Inc. 79-440 Corporate Centre Drive, Suite 114 La Quinta, CA f Project Designer: '-Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: JUL 0 1 2005 Date: 6/9/2005 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTG -1 Certificate of Compliance 3 Form LTG -2 Lighting Compliance Summary 6 Form LTG -MM Lighting Mandatory Measures 7 Form MECH-1 Certificate of Compliance 8 Form MECH-2 Mechanical Equipment Summary 10 Form MECH-3 Mechanical Ventilation 12 Form MECH-4 Mechanical Sizing and Fan Power 13 Form MECH-MM Mechanical Mandatory Measures 14 HVAC System Heating and Cooling Loads Summary 16 EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 CERTIFICATE OF COMPLIANCE Part 1 of 3 =LTG -1 PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 PROJECT ADDRESS 79-440 Corporate Centre Drive, Suite 114 La Quinta Building Permit # PRINCIPAL DESIGNER - LIGHTING TELEPHONE DOCUMENTATION AUTHOR TELEPHONEChecked by/Date Insu-form, Inc. 760) 324-2046 1Enforcement A en Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 2,248 Sq.Ft. 1 15 BUILDING TYPE 0 NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION 0 ALTERATION ❑ EXISTING + ADDITION METHOD OF LIGHTING COMPLETE BUILDING ® AREA CATEGORY [:] TAILORED PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNAT RE DATE Joan D. Hacker `� The Principal Lighting Designer hereby certifies that the propo ed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146 or 149 of Title 24, Part 6. Please check one: I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. X1,affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 37.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL HTING DESIGNER - NAME SIGN DATE LIC. # o �� 9✓eye 8/8z � ILIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. LTG -1: Required on plans for all submittals. Part 2 and 3 may be incorporated in schedules on plans. LTG -2: Required on all submittals. LTG -3: Optional. Use only if lighting control credits are taken. LTG -4: Optional. Use only if Tailored method is used. LTG -5: Optional. Use only if Tailored method is used. EnergyPro 3.1 By EnergySoft User Number 2655 Job Number: Page:3 of 16 LIGHTING COMPLIANCE SUMMARY Part 2 of 3 LTG -1 PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 INSTALLED LIGHTING SCHEDULE LAMPS BALLASTSLuminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION# watts er Lamp DESCRIPTION # Lam + # t3allast watts Total Watts 3 4 ft Fluorescent T8 Elec F32T8 3 32 Electronic 2.0 26 94.0 2,444 CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES 11E 11 ----i L- t�j' NOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 16 Subtotal from this Page 2,444 Lighting Schedule on Plans Shows Exterior Lighting Meets Total 2,444 450 ❑ Efficacy and Control Requirement of§130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) ❑ Control Requirements of§131(f) Adjusted Actual Watts 2,894 MANDATORY AUTOMATIC CONTROLS CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES 11E 11 ----i L- t�j' NOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 16 LIGHTING COMPLIANCE SUMMARY Part 3 of 3 LTG -1 NAME IDATE I Guida Survevina Inc. 1 6/9/2005 1 ROOM # DEFAULT AREA OR ZONE ID /s ft SF TOTAL WATTS B X C Office Zone 0.2 2,248 450 2,248 450 TOTAL 2,248 450 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET ❑ A ❑B CD ❑D ❑E ❑F GD LUMIN. TASK # OF TOTAL TOTAL ROOM # TOTAL AREA OR ZONE ID (SF) TOTALI 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the ligl level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1 +1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 2,248 450 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 16 LIGHTING COMPLIANCE SUMMARY LTG -2 PROJECT NAME DATE Guida Survevinci Inc. I 6/9/2005 ACTUAL LIGHTING POWER LUMINAIRE NAME NUMBER OF LUMINAIRES Total Wafts DESCRIPTION WATTS PER LUMINAIRE Ballast)Y CEC DEFAULT N" 3) 4 it Fluorescent T8 Elec 26 _(Including 94.0 [K] ❑ ❑ ❑ ❑❑ ❑❑ El El ❑❑ ❑❑ El El 2,444 Subtotal from this Page 2,444 Building Total 2,444 Portable Lighting (From LTG -1) 450 Less Control Credit Wafts (From LTG -3) Adjusted Actual Wafts E 2=894 LLOWED FIGHTING POWER (ChooseMethod) COMPLETE BUILDING METHOD BUILDING CATEGORY (From Table 1-M) WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS AREA CATEGORY METHOD AREA (SF) ALLOWED WATTS AREA CATEGORY (From Table 1-N) WATTS PER SF Office 1.30 2,248 2,922 PAGE TOTAL BUILDING TOTAL 2 248 2 248 AREA 2 922 2 922 WATTS TAILORED METHOD TOTAL ALLOWED WATTS O (From LTG -4 or from computer run.) EnergyPro 3.1 By EnergySoft User Number 2655 Job Number. Page:6 of 16 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE Guida Surveying Inc. I 6/9/2005 DESCRIPTION Designer Enforcement ❑X § 131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 0 § 131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system Is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. 0 § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All Installed fixtures shall be certified. § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. U § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. a§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is Included on plans. XJ § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel Inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. ❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 16 CERTIFICATE OF COMPLIANCE Part 1 of 2 MECH-1 PROJECT NAME DATE OF PLANS DATE Guida Surveying Inc. 6/9/2005 PROJECT ADDRESS BUILDING TYPE}❑( NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTIONL]X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ EXISTING + ADDITION 79-440 Corporate Centre Drive, Suite 114 La Quinta PROOF OF ENVELOPE COMPLIANCE PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED PRINCIPAL DESIGNER - MECHANICAL This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, TELEPHONE Building Permit # DOCUMENTATION AUTHOR Insu-form, Inc. SIGNATU TELEPHONE (760) 324-2046 Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 2,248Sq.Ft. 15 BUILDING TYPE}❑( NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTIONL]X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ EXISTING + ADDITION METHOD OF MECHANICAL PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATU DATE Joan D. Hacker Y) - The Principal Mechanical Designer hereby certifies that the prop+ ed uilding design represented in this set of constructio documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in Sections 110 through115, 120 through 124, 140 through 142, 144 and 145. Please check one: ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE DATE LIC. # MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. MECH-1: Required on plans for all submittals. Parts 2 may be incorporated in schedules on plans. MECH-2: Required for all submittals, but may be incorporated in schedules on plans. MECH-3: Required for all submittals unless required outdoor ventilation rates and airflows are shown on plans per Section 4.3.4. MECH-4: Required for Prescriptive submittals. MECH-5: Optional. Performance use only for mechanical distribution summary. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:8 of 16 CERTIFICATE OF COMPLIANCE Part 2 of 2 MECH-1 PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 SYSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS DHW Heater Office Mech System n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Electric Res 99% n/a n/a IN-SINK-ERATOR WA -3 Yes Yes n/a n/a n/a n/a n/a Programmable Switch Heating & Cooling Required n/a Yes 10.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 337 cfm Heat Pum 7.00 HSPF Packaged DX 13.0 SEER / 11.5 EER YORK D1EM048A25/46 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 2 Yes NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Timer O: Other C: Curve N: No I PIPE/DUCT INSULATION PROTECTED? I VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:9 of 16 1 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Guida Surveying Inc. DATE 6/9/2005 CHILLER AND T WER SUMMARY System Name Efficiency Tons PUMPS BHP Motor Eff. Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 0.75 77.0%1100.0% none 1QHW/ BOILER SUMMARY Energy Factor I or Recovery Efficiency Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. IN-SINK-ERATOR WA -3 Instant Elec Standard 1 4,437 0 0.98 n/a n/a CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Tye Pty,__ Output Aux. kW Eff. Outut Sensible Efficiency Economizer Type YORK D1EM048A25/46 Packaged DX 2 47,500 10.0 7.00 HSPF 46,500 32,55C 13.0 SEER / 11.5 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLYFAN RETURNF System Name Fan Ty_ a Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. YORK D1EM048A25/46 Constant Volume Blow -Through 1,600 0.75 77.0%1100.0% none I EnergvPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 16 1 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME DATE Guida Surve in Inc. 6/9/2005 ZONE TERMINAL SUMMARY n. CFM EXHAUST FAN SU Moto Drive CFM I BHP Eff. Eff. I I Type Output I EnerovPro 3.1 By EnemvSoft User Number: 2655 Job Number: Paae:11 of 16 1 Room Name Qty. CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP Motor Eff. Drive Eff. I EnerovPro 3.1 By EnemvSoft User Number: 2655 Job Number: Paae:11 of 16 1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 MECHANICAL VENTILATION a a© a a o© a 0 0 0 ZONE/SYSTEM Office Zone Office Mech System AREA BASIS DESIGN OUTDOO AIR CFM COND. 337 MIN. AREA CFM CFM (SF) PER SF (B x C) 2.248 0.15 337 OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (ExF) 22.5 15.0 337 REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOO AIR CFM 337 337 337 337 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fan; K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paw 12 of 16 1 MECHANICAL SIZING AND FAN POWER MECH-4 PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 SYSTEM NAME Office Mech System FLOOR AREA 2,248 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: - OUTDOOR DRY BULB TEMPERATURE - OUTDOOR WET BULB TEMPERATURE - INDOOR, DRY BULB TEMPERATURE 2. SIZING: - DESIGN OUTDOOR AIR - ROOM LOADS - RETURN VENTED LIGHTING - RETURN AIR DUCTS - RETURN FAN - SUPPLY FAN - SUPPLY DUCTS SAFETY / WARM-UP FACTOR (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 337 CFM (MECH 3; COLUMN 1) TOTALS MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY / WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN FA] FAN DESCRIPTION Supply Fan DESIGN BRAKE HP 0.750 © a EFFICIENCY MOTORDRIVE 77.0%1 100.0% NOTE: Include only fan systems exceeding 25 HP (see Section 144). Total Fan System Power Demand may not exceed 0.8 Watts/cfm for constant volume systems or 1.25 Watts/cfm for VAV systems. 3.1 User Number 2655 Job Number: COOLING HEATING 1130F 26 of 78 OF 74 OF 70 of 13,339 15,676 51,923 20,403 0 n/a 2,596 1,020 0 0 0 0 2,5961 1 1,020 70,455 38,119 1.21 1.43 85,250 54,511 58,7811 1 130,739 Btu / Hr Btu / Hr K a NUMBER OF FANS PEAK WATTS B x E x 746 / (C X D CFM (Supply Fans) 2.0 1,453 3,200 TOTALS 1 453 3 200 TOTAL FAN SYSTEM POWER DEMAND 0.454 WATTS / CFM Col. F / Col. G Page: 13 of 16 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Guida Sulvevinci Inc. I 6/9/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. X❑ § 115(a) Fan type central furnaces shall not have a pilot light. X] § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. a§ 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. a§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. 0 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 16 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 Description Designer Enforcement Ventilation n§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. X❑ § 122(f) Gravity or automatic dampers Interlocked and closes on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. § 121(f)l Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or n§ 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divlce; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 if a circulating hot water system is Installed, It shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. FXJ § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X] § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 15 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Guida Surveying Inc. 6/9/2005 SYSTEM NAME FLOOR AREA Office Mech System 2,248 Number of Systems 1 2 Heating System Output per System 47,500 Total Output (Btuh) 95,000 Output (Btuh/sqft) 42.3 Cooling System Output per System 46,500 Total Output (Btuh) 93,000 Total Output (Tons) 7.8 Total Output (Btuh/sgft) 41.4 Total Output (sgft/Ton) 290,1 Air System CFM per System 1,600 Airflow (cfm) 3,200 Airflow (cfm/sgft) 1.42 Airflow (cfmrron) 412.9 Outside Air (%) 10.5 Outside Air (cfm/sgft) 0.15 Note: values above given at ARI conditions 26.0 OF 65.1 OF Outside Air 337 cfm Supply Fan 3200 cfm 69.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 4,128 51,923 4,496 578 20,403 0 2,596 1,020 0 0 337 13,339 2,174 337 15,676 0 0 2,596 1,020 70,455 6 670 38,119 YORK D1EM048A25/46 58,781 26,475 62,479 10.0 kW Supplemental Electric 68,260 Total Adjusted System Output 58,781 26,475 130,739 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 4 pm Jan 12 am RICS (Airstream Temperatures at Time of 65.1 of ■ 83.4 of . 103.5 of Heating Coil Aux. Heat Coil 1% Return Air Ducts `i Supply Air Ducts 103.2 of R007M7571 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.9/77.6OF 78.7/66.8OF 78.7/66.9OF 61.4/60.5OF i Supply Air Ducts Outside Air 0 ,. 337 cfm Supply Fan Cooling Coil 62.2 / 60.7 of 3200 cfm 62.8% R.H. ROOMS 74.8/65.4 of 74.0/65.1OF 1% Return Air Ducts `S L EnergyPro 3.1 By Energysoft User Number. 2655 Job Number: Page: 16 of 16