Loading...
BSOL2015-015178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (i c&,,,, 4 4v Q" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL2015-0151 Property Address: 52015 AVENIDA BERMUDAS APN: 773235012 Application Description: 9.01kW PV SYSTEM - (34) 270W PANELS/(1) INVERTER Property Zoning: Application Valuation: $20,000.00 Applicant: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO, CA 94402 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division "Busines Professions Code, and my License is in full force and effect. Lice�te�A�ss: C4 B C10 A C20 icenDate: ' IIryV//'I Contracto < I hereby affirm under penalty of perjury that I am exempt from IW Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ I, as owner of the property, or my employees with wages as their sole compenA£tion, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: c VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: TRAVIS BROWN 52015 AVENIDA BERMUDAS LA QUINTA, CA 92253 Contractor: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO,CA 94402 (650)963-4722 Llc. No.: 888104 Date: 9/15/2015 O C c z n C./� O T i -A c o z N m n O v i til zm WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance 2rk for which this permit is issued. I have and will maintain workers' compensation insurance, as required by 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree th , i hould b o e subject to the workers' compensation provisions of Section 700 o the La or de, I shall forthwith compI w h tho provisions. U'�7ZVGI Date: Applican WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CARAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official fora permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state s relatin to building construct n, and hereby authorize representative o t i to a ter u n e above men r for inspection purposes. Date: 1 S Signature (Applicant or ent): : DESCRIPTION FINANCIAL i• l• ACCOUNT.' QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 9/14/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9185 221033 AZA Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 9/14/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9185 221033 AZA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 9/14/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9185 221033 AZA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $24.17 $24.17 9/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9218 221034 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $24.17 $24.17 9/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9218 221034 SKH Total Paid for ELECTRICAL: $96.68 $96.68 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 9/14/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SOLARCITY CORPORATION CHECK R9185 221033 AZA Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: $189.53 $189.53 Description: 9.01kW PV SYSTEM - (34) 270W PANELS/(1) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 8/25/2015 PJU Approved: 9/11/2015 LUR Parcel No: 773235012 Site Address: 52015 AVENIDA BERMUDAS LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 92 Lot: 1 Issued: UNIT 11 Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $20,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 NOTES Details: 9.OkW SOLAR ARRAY - (34) 265W KYOCERA PANELS W/ (1) SOLAREDGE SE7600-US002SNU2-AFCI INVERTER [602SF] TO INCLUDE NEW 200AMP PANEL UPGRADE. 2013 CALIFORNIA ELECTRICAL CODE. Printed: Tuesday; September 15, 2015 4:34:53 PM 1 of 3 J srsTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY, TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL LUIS URIBE 9/11/2015 9/11/2015 SENT ELENA AN EMAIL PERMIT IS READY TO BE ISSUED. PLAN CHECK PICKED UP STEPHANIE KHATAMI 9/2/2015 9/2/2015 PLAN CHECK SUBMITTAL PHILIP JUAREZ 8/25/2015 8/25/2015 RECIEVED THREE SETS RECEIVED CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)773-8728 CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)773-8728 OWNER TRAVIS BROWN 52015 AVENIDA LA QUINTA CA 92253 (760)773-8728 BERMUDAS Printed: Tuesday; September 15, 2015 4:34:53 PM 1 of 3 J srsTEMS REVIEWE REVIEW TYPE RETURNED R SENT DATE DUE DATE DATE STATUS REMARKS NOTES Printed:. Tuesday, September 15, 2015 4:34:53 PM 2 of 3 SYST[MS INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 9/14/15 R9185 221033 CHECK SOLARCITY AZA CORPORATION Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $24.17 9/14/15 R9185 221033 CHECK SOLARCITY AZA FIRST 20 CORPORATION PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 9/14/15 R9185 221033 CHECK SOLARCITY AZA FIRST 20 PC CORPORATION PV SYSTEM - MISC 101-0000-42403 0 $24.17 $24.17 9/15/15 R9218 221034 CHECK SOLARCITY SKH EQUIPMENT CORPORATION PV SYSTEM - MISC 101-0000-426000 1 $24.17 1 1 $24.17 1 9/15/15 R9218 1 221034 1 CHECK 1 SOLARCITY SKH EQUIPMENT PC CORPORATION Total Paid for ELECTRICAL: $96.68 $96.68 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 9/14/15 R9185 221033 CHECK SOLARCITY AZA CORPORATION Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: REVIEWE REVIEW TYPE RETURNED R SENT DATE DUE DATE DATE STATUS REMARKS NOTES Printed:. Tuesday, September 15, 2015 4:34:53 PM 2 of 3 SYST[MS NON-STRUCTURAL - LUIS URIBE 8/25/2015 9/1/2015 9/2/2015 REVISIONS REQUIRED 1 WK 2ND BLDG NS (1 WK) LUIS URIBE 9/3/2015 9/10/2015 9/11/2015 APPROVED Printed: Tuesday, September 15, 2015 4:34:53 PM 3 of 3 SYS7F.lv1S Birt. # Clt}/ of. Quinta / BulkMg 8r Safety MUM P.O. Box 1504,78-495 Calle Tampfco J / 4.Quinta, CA 92253 -:(760) 777 7012 Building Permit •Application and Tracking Sheet Permit #S Project Address: tT Owner's Name:. A P. Number: Adder: . Legal Description: City, ST, Zip: La Quinta, CA Coob�aetor Solar City Telephone: Address: 3055 Clearview Way. P_roj«xDescription: 2qrobf mounted solar panels . city, s-t, zip: San Mateo, CA, 94402 inverters . Q Telephone: 650-638-1028 State Lir # : 888104 city Lic M Arch., Eagr., Designer. Address: F I City, ST, Zip: Telephone: State Lia #: Name of Coma Person: Elena Loya Construction Type:. oc aupancy: Project type (circle ont): New Add'n Alter Repair Demo Sq. # Stories Telephone # of Contact Person: (442.)256-1134 Ekeatd Value of Project APPLICANT: DO NOT WRITE BELOW THIS Submittal BeVd Recd TRACMG A PERMIT FEE . Plan Sob Plan cheek submitted % Item Amount StrgetuM1 Cala. Reviewed, ready for corrections Plan Check Deposit- . Tanis Cates. Called contact Person Pian Check Balance Tide 24 Calcs. Pians picked up Construction Flood plain plan Plans resubluitted.. Mechanical Grading plan 2'! Review, ready for corrections/issue Electrical Subcontactor Lk called contact Person Plumbing Grout Deed Plans picked up Shu H.O.A. Approval Plans resubmitted Grading IN HOUSE-- 7r° Review, ready for eorrectionOssae Developer Impact Fee Planning Approval called contact Person A".P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees [CALCULATION;OF DESIGN=UIIIND_LOAD9=MP4__ Mounting Plane Information Roofing Material KZ Spanish Tile Roof Table 30.3-1 PV System Type ------KA SolarCity Sleek_ MountT'" Section 26.8 Section 26.6-1 Spanning Vents V No Fig. 26.5-1A Standoff Attachment Hardware Velocity Pressure SM Tile Section 26.7 Roof Slope 160 Fig. 30.4-2A/B/C-5A/B Rafter_Spacing h 24" O.C. Section 26.2 Framing Type Direction Y -Y Rafters T -allow Purlin Spacing _X -X Purlins Only NA DCR Tile Reveal Tile Roofs Only 12" Tile. Attachment System Tile Roofs Only SM Tile ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code KZ ASCE 7-10 Table 30.3-1 Wind.Design Method ------KA Partially/Fully_Enclosed.Method Section 26.8 Section 26.6-1 Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category Velocity Pressure C Section 26.7 Roof Style Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor Wind Directionality Factor ------KA 1.00 0.85 Section 26.8 Section 26.6-1 Kd Im ortance Factor I NA Not -Staggered Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Wind Drnccura Ext. Pressure Coefficient U GC -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GC W 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GC) Equation 30.4-1 Wind Pressure U -19.6 psf Wind Pressure Down 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing,_^ Landscape 72" 39" Max Allowable Cantile_v_er _Landscape_._ _ 24" NA_ Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 19 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -195 lbs Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand/Capacity DCR 43.7% —j X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait_ 19" NA Standoff Configuration Portrait Not -Staggered MAx Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind_Uplift at Standoff T -actual -218 lbs Uplift Capacityof Standoff T -allow 446 lbs Standoff Demand Ca aci DCR 48.9%