BSOL2016-0091r ;
787495 CALLE.TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: BSOL2016-0091
�v4.f�4�rw
COMMUNITY DEVELOPMENT DEPARTMENT
. BUILDING PERMIT
Property Address:
52140 AVENIDA CARRANZA
APN:
773221006
Application Description:
GUTIERREZ / 4.9kW PV SYSTEM - (19) 260W PAN+P300 OPT/(1) INV
Property Zoning:
Application Valuation:
$10,868.00
Applicant:
VIVINT SOLAR DEVELOPER
LLC
3301 N THANKSGIVING WAY STE
500
LEHI, UT 84043.
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C46. CSO License No.: 97 56 `
�Date� _Co tractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requites a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( 11, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(� I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
I I I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/20/2016
Owner:
BARBARA GUTIERREZ
, 92253
Contractor:
VIVINT SOLAR DEVELOPER LLC
3301 N THANKSGIVING WAY STE
500
LEHI, UT 84043
(855)877-2974
Llc. No.: 973756
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
comp VI
,ion, as provided for by Section 3700 of the Labor Code, for the performance
of thek for which this permit is issued.
have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier:- Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
n
Date: Applicant: C�IMI�•s✓
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-menY ne11d property for inspection purposes. 3 -
Date: �O Signature (Applicant or Agent):
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT. PAID
PAID DATE
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00
5/20/16
PAID BY METHOD RECEIPT # CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC CHECK - R15678 1862
RSE
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$24.17
5/20/16
PAID BY
METHOD
• RECEIPT #
CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R15678
1862
RSE
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$24.17
5/20/16
PAID BY
METHOD
RECEIPT #
-CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R15678
1862
RSE
Total Paid for ELECTRICAL: $48.34 $48.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
5/20/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
VIVINT SOLAR DEVELOPER LLC
CHECK
R15678
1862
RSE
Total Paid for PERMIT ISSUANCE: .$91.85 $91.85
TOTALS:
Description: GUTIERREZ / 4.9kW PV SYSTEM - (19) 260W PAN+P300 OPT/(1) INV
Type: SOLAR Subtype: Status: ISSUED
Applied: 4/20/2016 RSE
Approved: 5/3/2016 AOR
Parcel No: 773221006 Site Address: 52140 AVENIDA CARRANZA LA QUINTA,CA 92253•
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 78 Lot: 17
Issued: 5/20/2016 RSE .
UNIT 10
Lot Scl Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $10,868.00 Occupancy Type: Construction Type:
Expired: 11/16/2016 RSE
No. Buildings: 0 No. Stories: 0 No. Unites: 0
ACTION DATE
Details: 4.9kW SOLAR ARRAY - (19) 260W YINGLI PANELS + P300 SOLAREDGE POWER OPTIMIZERS W/(1) SOLAREDGE SE380OA-US-R
INVERTER [322SF] 2013 CALIFORNIA ELECTRICAL CODE.
17 I
j Applied to Approved
Approved to Issued
Printed: Friday, May 20, 2016 2:33:17 PM 1 of 2 C
SYSTEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL AJ ORTEGA
5/4/2016
5/4/2016
EMAILED PAULA THAT PLANS ARE APPROVED AND PERMIT IS
READY TO ISSUE.
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
VIVINT SOLAR DEVELOPER LLC
3301 N THANKSGIVING
WAY STE
LEHI
UT
84043.
businesslicensing@vivi
• nsolar.com
CONTRACTOR
VIVINT SOLAR DEVELOPER LLC -
3301 N THANKSGIVING
WAY STE
LEHI
UT
84043
businesslicensirig@vivi
nsolar.com
OWNER
BARBARA GUTIERREZ
92253
Printed: Friday, May 20, 2016 2:33:17 PM 1 of 2 C
SYSTEMS
Permit Details PERMIT NUMBER
City of La Quinta BSOL20'ft - 1
PARENTTOTALS:
PROJECTS
REVIEWS
REVIEW TYPE
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #.
METHOD
PAID BY
BOND
INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
5/20/16
R15678
1862
CHECK
VIVINT SOLAR
RSE
DEVELOPER LLC
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
PV SYSTEM - ARRAY,
101-0000-42403
.0
$24.17
$24.17
5/20/16
R15678
1862
CHECK
VIVINT SOLAR
RSE
FIRST 20
DEVELOPER LLC
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$24.17
5/20/16
R15678
1862
CHECK
VIVINT SOLAR
RSE
FIRST 20 PC
DEVELOPER LLC
Total Paid for ELECTRICAL: $48.34. $48.34
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
5/20/16
R15678
1862
CHECK
VIVINT SOLAR
RSE
DEVELOPER LLC
Total Paid for PERMIT ISSUANCE: $91.85 $91.85
$141.19 $141.19
Printed: Friday, May 20, 2016 2:33:17 PM 2 of 2
SYSTEMS
PROJECTS
REVIEWS
REVIEW TYPE
REVIEWER SENT DATE
DUE DATE RETURNED
DATE
STATUS
REMARKS NOTES
1ST BLDG NS (1 WK)
AJ ORTEGA 1 4/20/2016 1
4/27/2016 1 5/3/2016
APPROVED
BOND
INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME SUBDIR ETRAKIT ENABLED
DOC
5/4/2016
AJ ORTEGA
SOLAR PLAN
(APPROVED)
BSOL2016-0091- SOLAR 1
PLAN (APPROVED).pdf
Printed: Friday, May 20, 2016 2:33:17 PM 2 of 2
SYSTEMS
Bin ii
•, , •
• City of La Quints
Building w Safety Dmi6n
P.O Box 1504,78-495 Calle Tampico
4.Qrdnta, CA 92253 -:(760) 777-7012
Building Permit Application'and Tracft Sheet
Pelt
bw:�o
Projec t Addrrem: Lf 0 A VPA I a (-"I r AbIA
owner's Mame arkhr
A. P. Number -7 0) % 0 (�
Address: 6.,—VI yv yq y
Legal Description:
Conhutor. Iff I h S.6 a >l e/ .e r L C
City, ST, Zip: t%t Af (. 7 c? S�7
Telephone:
Address J P1Gi7a
Project Description:
—lid- u/ (U146 -&City,
// I
ST, zip' htd a CA 924?3i
r
t Sd ave . V, ltaqtA 'l.I
Telephone:
State Lia ll : City Lic, #,wc-!
Arcfi , Eng.. Designer.
/At flP/fPI,,
-
. .
Address:
CIty., ST, Zip:
-
Telephone:
Construction Type- Occupancy:
Project type (circle one): New Add'a Alter Rapair Demo
Sq. FL: #Stories: # Uniq
State Lie: #:
Name of Contact Person: 6(o' F� �'
Telephone iE of contact Person: ,. h✓ ' �%
fist mWxd Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS EINE
M
Submittal
Req'd
Reed TRACKING PERMIT FM—
Piga Sets
Plan Cheeksubmitted•
Item
Amount
Structural Cales.
Truss Caks.
_
Reviewed, ready
Called Contact
. Plan Check Deposit
Plan Check Balance, •
Title IA Caleb.
Plans plaid ep
Canstruetlou
Flood plain plan
Pians resubmitted;
Mecharikal
Giading plan3''
Review, ready for carrectio oisue
Electrical
Subcontattaor List
Caved Contact Person
Plumbing
Grant Deed
I Plans picked up
SM,L
H.O.A. Approval
Plans roaabmttted
Grading
EN ROUSE:-
"' Reyiew, ready for correetionslisme
Developer Impact Fee
Planning Approval.
Called Contact Person
A.U.P.
Pub. WkL Appr '
Date of permit issue
School Fees
Total P nes
7-2
(�i1f52 Lam/ .
BDH
�11IGl I1VG ION COMPANY
7056 Archibald Ave Ste 102-432
Corona, Ca 92880
Phone: 951.220-8650
bharris@bdhengineering.com
April /14, 2016
It has been determined after analyzing the existing Residential Electrical panel at
52140 Avenida Carranza LA QUINTA, CA
The installation of the Overcurrent Protective Device (OCPD) shown on the 1 -Line
Diagram meets all applicable California Building Codes (CBC), California Electrical Codes
(CEC) and National Electrical Codes (NEC).
The existing residential electrical panel rating matches the ratings shown on the 1 -line
diagram
Due to age and weathering conditions, the label specifications are no longer visible on the
existing residential electrical panel. However, my analysis of the existing electrical panel is
Based primarily on the evaluation of several congruent existing residential electrical
panels installed at neighboring addresses that contained the appropriate labeling.
Based on knowledge of the existing residential panel and familiarity with the make/model,
amount of breaker slots it contains, and the physical characteristics of the bus and cable
Bus Size
125
lotal # o
slots 14
EFRTrical
Busbar physical size x size rated or
incoming
Gable size size rated tor
E—R—isfina
main rea er s
Based on this analysis, it is my conclusion that the existing residential electrical panel
is a 125 A main buss
In accordance to CEG 705.12(D)(7), the solar breaker shall be located at the furthest point from
the main breaker which may result in the rearrangement of existing breakers. This
rearrangement shall be done in compliance with all applicable CBCs, CECs, and NECs
V%OFE ssioN4
yA:o00yQP'P`�2
c No. E38753
* 6-30-17
D
\rF A
DF CA
4/14/16
Bobby D Harris III, PE
C Ti -
AU
POWER TO T.MIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS AS SHOWN
N
JUNCTION BOX
LOCATED ON ROOFTOP
SOLAR MODULES WITH POWEF
OPTIMIZERS MOUNTED ON THE
BACK OF EACH MODULE
PV INTERCONNECTION POINT,
LOCKABLE DISCONNECT
SWITCH,& UTILITY METER
LOCATION }
52140 Avenida Carranza
`
e
"tA
M1b`^t AI
`°
fill
vivint. so l a r
Structural Group
Scott E. Wyssling, PE
Senior Manager of Engineering
March 10, 2016
Revised April 20, 2016
Mr. Dan Rock, Project Manager '
Vivint Solar
3301 North Thanksgiving Way, Suite 500
Lehi, UT 84043
3301 North Thanksgiving Way, Suite 500
Lehi, UT 84043
P: (801) 234-7050
scott.wyssling@vivintsolar.com
Re: Structural Engineering Services
Gutierrez Residence
52140 Avenida Carranza, La Quinta CA
S-4846158
4.94 kW
Dear Mr. Rock:
Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of
the above referenced home:
1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site
information including size and spacing of members for the existing roof structure.
2. Design drawings of the proposed system including a site plan, roof plan and connection details for
the solar panels. This information was prepared by the Design Group and will be utilized for
approval and construction of the proposed system.
3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar
system.
4. Photographs of the interior and exterior of the roof system identifying existing structural members
and their conditions.
Based on the above information we have evaluated the structural capacity of the existing roof system to support the
additional loads imposed by the solar panels and have the following comments related to our review and evaluation:
Description of Residence:
The existing residence is typical wood framing construction with the roof system consisting of the following:
• Roof Sections (1 and 2): Prefabricated truss with all chords constructed of 2x4 dimensional lumber
at 24" on center. The attic space is unfinished and photos indicate that there was free access to
visually inspect the size and.condition of the roof members.
All wood material utilized for the roof system is assumed to be Douglas -Fir #2 or better with standard construction
components. The existing roofing material consists of composite shingle.
'Stability Evaluation:
A. Wind Uplift Loading
1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other
Structures, a wind speed of 130 mph based on Exposure Category C and 13 degree roof slopes on
the dwelling areas.
2. Total area subject to wind uplift is calculated for the Interior, Edge and Comer Zones of the
dwelling.
vivint. solar
Page 2 of 2
B.. Loading Criteria
10 PSF = Dead Load (roofing/framing) 20 PSF = Live Load (Roof snow load)
3 PSF = Dead Load (solar panels/mounting hardware)
Total Dead Load = 13 PSF
The above. values are within acceptable limits of recognized industry standards for similar structures and in
accordance with the 2013 California Building Code. Analysis performed on the existing roof structure utilizing the
above loading criteria indicates that the existing members will support the additional panel loading without damage,
if installed correctly.
C. Roof Structure Capacity
1. The photographs provided of the attic space and roof rafters show that the framing is in good
condition with no visible signs of damage caused by prior overstressing.
D. Solar Panel Anchorage
1. The solar panels shall be mounted in accordance with the most recent "EcoFasten Solar Installation
Manual", which can be found on the EcoFasten Solar website (www.ecofastensolar.com). If during
solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our
office should be notified before proceeding with the installation.
2. The solar panels are 1 '/z' thick and mounted 4 '/2" off the roof for a total height off the existing roof
of 6". At no time will the panels be mounted higher than 6" above the existing plane of the roof.
3. Roof Sections (1 and 2): Considering the roof slopes, the size, spacing, condition of the roof, the
panel supports shall be placed at and attached no greater than every third roof member as panels
are installed perpendicular across members and no greater than the panel length when installed
parallel to the members (portrait). No panel supports spacing shall be greater than three (3) spaces
or 72" o/c, whichever is less.
4. Panel support connections shall be staggered to distribute load to adjacent members.
Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately
support the additional loading imposed .by the solar panels. This evaluation is in conformance with the 2013
California Building Code, current industry standards and practices, and the information supplied to us at the time of
this report:
Should you have any questions regarding the above or if you require further information do not hesitate to contact
me.
gP.Regaar , S. .
CA License No. S5632
vivint. solar
STRUCTURAL ENGINEERS
October 23, 2015
Rillito River Solar, LLC dba EcoFasten Solar
289 Harrel Street
Morrisville, VT 05661
TEL: (877) 859-3947
Attn.: Engineering Department,
Re: Engineering Certification for the EcoFasten Rock -it System Installation Manual
This letter is to document that PZSE, Inc. -Structural Engineers has reviewed EcoFasten Rock -it System
Installation Manual published October 12, 2015 and specifically the "Loading Tables".
SCOPE OF THE SYSTEM:
The EcoFasten Rock -it System is a solar panel support system for installing solar photovoltaic arrays on sloped
roofs of buildings. Typically such buildings are residential with shingle or tile roofs. The number and spacing of
attachments to the roof structure can vary depending on various site specific criteria including, but not limited
to, roof slope, spacing of supporting structural members and environmental loading.
SCOPE OF OUR REVIEW:
PZSE, Inc.—Structural Engineers, provided a review of the following
• Rock -it System design methodology
• Rock -it System Installation Manual
• Rock -it System Loading Tables
and has determined that all information, data and analysis contained within the Installation Manual are based
on, and are in compliance with, the structural requirements of the following Reference Documents:
• Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-10
• International Building Code, 2012 Edition, by International Code Council, Inc.
• California Building Code, 2013 Edition, by California Building Standards Commission
• Aluminum Design Manual, 2010 Edition, by The Aluminum Association
This letter certifies that the)EcoFasten Rock -it System Installation Manual and Loading Tables are in
compliance with the above Reference Documents.
8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com
Page 1 of 2
r
STRUCTURAL ENGINEERS
DESIGN RESPONSIBILITY:
The Rock -it System Installation Manual is intended to be used under the responsible charge of a registered
design professional where required by the authority having jurisdiction. In all cases, the user of the Installation
Manual has sole responsibility for the accuracy of the design and integrity of the system.
The Installation Manual does not check the capacity of the building structure to support the loads imposed on
the building by the array, such as bending strength of roof rafters spanning between supports. This requires
additional knowledge of the building and is outside the scope of the Installation Manual and our review.
If you have any questions on the above, do not hesitate to call. /
Prepared By: -
PZSE, Inc. - Structural Engineers
Roseville, CA
1
8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com
Page 2 of 2
16.0%
MAXIMUM EFFICIENCY
25 YEAR
LINEAR POWER WARRANTY
0-3%
POWER TOLERANCE
YINGLISOLAR.COM
YINI LAR
PROVEN PERFORMANCE
AND VERSATILITY
Our most popular product fine, the YGE 60 Cell Series, is ideal for a broad
range of applications. It is proven to perform in tens of thousands of projects
across the Americas, from residential and commercial rooftops to ground -
mounted solar farms.
Trusted Partner
Yingli is one of the world's largest solar module manufacturers with over 10 GW
deployed worldwide, and Yingli modules are trusted by leading energy providers and
financial institutions in more than 85,(100 pmjerts in the Americas.
More Energy per Watt
Yingli modules deliversupedor power output in a.variety-of temperature and irradiance
conditions, and self-cleaning anti -reflective coated glass reduces soiling to help
maximize power output. Performance is backed by our 25 -year linear warranty.
Designed to Outlast
10 Tested to the industrys most rigorous durability standards, Yingli modules are PID -
resistant in conformance with IEC 62804 (draft). To ensure reliable performance, Yingli
uses quality components such as DuPont'" Tec lar® PVF film -based backsheets.
Best -In -Class Technical Support
Yngll's locally -based engineering team is trained in system design and operations to
provide field -support and value-added after sales services, including commissioning
and field-testing support Our PV Testing Lab in California provides a resource for
evaluating technical inquiries.
Warranty Information
Ten,year limited product warranty. Industry leading 25 -year performance warranty adds value:
by guaranteeing power output on an annual basis, in compliance with our warranty terms and
conditions.
Performance Modeling
For those interested in obtaining module performance modeling files for system energy yield
simulation, please contact Yngli at simulation®yingliamericas.com.
Qualifications & Certificates
UL 1703 and UL 1703, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, SA8000
LYrp�nw
C&S
F&__11
fBO�utmo�
=14
00 wotwH
LWEO
UNVAWM. I
To"MIALA I
(PHOTOVOLTAIC NODULE)
YG E 60CELL
SERIES
60/.rntil6cg=lGrmsik /
Numbrir of modhdas pr pallet
156inm x 156mm
Etcapwlwrt (msteala0
athylerw Virryl amtata (EVA)
eeekshoat (material / soler)
6uorepolymerbaead with EVA primer / white or bled[ .
Frame (matorW / odor)
Powered
by YINGLI
x IP65 1
ELECTRICAL PERFORMANCE
1000mm / quare
Connector (type / Ingress pmtectim rating)
MC4 J IP67 or Amphenol f14 / IP68
Module typo -
Yt260P.29b
YL255P,29b
YL250P.29b
YL245P.29b
YL24OP-M
Power autput
Psi„
W 260
255
2$0
245
240
Power output tolorenoer
APm.s
%
-01+3
Modulo offldency
11-
% 1&0
15.7
15.4
15.1
11.0
Voltage at Psss
V -e ,
V 30.3
30.0
29.6
29.6
29.3
Curtest at P_
Isar
A &59
8.49
8.29
6.28
0.18
opon•dnultvekage
_ V_
V 37.7
37.7
37A
37.5
373
shortclrcok current
1.
A 9.09
9.01
&92
&63
&76
STC: 1000W/m+ Inadisrxe, MC cell termrareWfq AM 1.SG spxtnen -,&q to EN 60704.3
gtnperetuo krodienco YL26W,29b
YL255P39b
YL250P296
YL24SP29b
YL210P29b
'
sc -
W/mr W
W
W
W
W
High Temperatue Condition
NTC 75
1000 203.7
199.8
195.9
192.0
188.1
Ntornkhd Operating Call Temperature
NOCT 46
600 190A
186.9
183.2
179.5
17&9
LowTimpratunsCetdltlmt
LTC 1s
S00 135.7
133.1
13116
127.9
125.3
Lew Irredlrxe Condition
LIC 2St
200 50.3 4
49A
4111.4
47.4
OPERATING CONDITIONS
., . ....
_THERMAL CHARACTERISTICS
IlnllR Inch (MM)Max.
eyato Voltage
1000Voc
.. Tettpwebrro cooffkirtt of P.rs
%PC 443
INaa sorlm tote rstb o
ISA
Temperature coefRdrtt of V
%I*C 4132
L1mNltg reVerr eumnl
15A
Timprathre coo(IidarR of 4
9Y'COA4
]LIi
t.3B
/ Oporotkg trnparabae now
40 to 165nF (-40 to 8s -q Tamprebne cooffidw of V.w
WT 4.62
MSL hailstone Impon (damotw / Vdodty)
25mm / 23m/s
CONSTRUCTION MATERIALS
Front carer(materlol/thiclaoW
low -iron compared Ow/32- .
Call(gtrrhtky/material/dhtanalre)
60/.rntil6cg=lGrmsik /
Numbrir of modhdas pr pallet
156inm x 156mm
Etcapwlwrt (msteala0
athylerw Virryl amtata (EVA)
eeekshoat (material / soler)
6uorepolymerbaead with EVA primer / white or bled[ .
Frame (matorW / odor)
anodkod aluminum /s&h or blade
Juncdan box 0tgreee protocUon nstktg)
x IP65 1
Colo (lrgth / croaoeawonfii real.
1000mm / quare
Connector (type / Ingress pmtectim rating)
MC4 J IP67 or Amphenol f14 / IP68
GENERAL CHARACTERISTICS
Modula dimensions (L / W / H)
6457in(1640mh) /36.98'm (99Uma / /.36n (35mrn)
Modula weight
40.666 (16_%W
Numbrir of modhdas pr pallet
29
Number of paliots par 40' container
28
Packaging box dlmwnbru (L / W / H)
67in (1700non) / 45in (I135mm) / 46in (I1651mo)
Packoyhg box sheIL4,L
12320m (]6&91
Fire claviRtaUon type
f Type 1 and Type 2
QWaming: Read the installation .and User
Mbnual in its entirety before handling, installing, and operating Yingli modules.
Yingli Green Energy Americas, Inc.
info@yingliamericas.com
Tel: +1 (888) 686-8820
YINGLISOLARXOM j NYSE:YGE
C YIng6 Green Energy Holding Co. Ltd. I YGE6OCellSeries2015_EN 201502_VO7
Pdbm�•.nr/LWau..g.r�w/e.J�w.sh n/Er dPam Ge Nmmv.rd Cm.psy n•r4.alNr.
IFaryvphr,pT.mrlw Muga. vv.m w..m+..am.rn.vq.n mora. u0ow pnmraie
YIN SOLAR
0
I
ROCK -IT SYSTeI'1'1
Designed with the installer in mind.
EcoFasten Solar specializes in solar roof attachments that are the easiest to install, most secure and cost-
effective solutions for installers. EcoFasten offers a wide variety of standard products as well as custom
solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and
approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented
conical sealing system has been in service in the snow guard and solar industry for two decades.
FeaTures
Fastest, easiest to level system on the market SIMPLE- only 3 components
• ETL listed to UL SUB 2703 Fixed wire management tray
• Class A Fire rating with Type 1 modules North-South adjustability of up to 4'
• Integrated electrical bonding Only one tool required (1/2" deep well socket)
SYSTem comPonenTS
ROCK -IT MOUI'1T
Array sKIrT
ROCK -IT COUPLinG
agDEcoFasten Solar
EcoFasten Solar products are protected by
the following U.S. Patents:
8,151,522 B2 8,153,700 B2 8,181,398 B2
8,166,713 B2 8,146,299 B2 8,209,914 B2
8,245,454 B2 8,272,174 B2 8,225,557 B2
www.ecofastensolar.com info@ecofastensolar.com • 877-859-3947
ROCK=IT MounT AssemBLY
I
NOTe: ITems 1-12 SHIP assemBLeD
1 S/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Mid -Clamp 6005A -T5
3 Compression Spring 300 Series SS
4 Tie Plate 6005A -T5 AL
5 Rock -It Shelf 6005A -T5 AL
6 Flange Level Nut 300 Series SS
7 Packaging 0 -Ring (Remove Prior to Installation)
8 Rock -It Pedestal 6005A -T5 AL
9 3/8" ID Star Lock Washer 300 Series SS
10 3/8"-16 Hex Tap Bolt 300 Series SS
11 5/16"-18 x .375" Hex Flange Bolt 300 Series SS
12 Rock -It -Slide 6005A -T5 AL
13 5/16" ID EPDM Bonded Washer 300 Series SS
14 5/16"x 4!'l lex Lag Screw or 5/16"-18 X 1.50"
Hex Bolt 300 Series SS
ROCK -IT COUPLII'1G A552f71BLY
NOTe: ITems 1-4 SHIP assemBLeD
1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Coupling Mid Clamp 6005A -T5 AL
3 Compression Spring 300 Series SS
4 Rock -It Coupling Shelf 6005A -TS AL
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
array LaY OUT
• Find the required'structural attachment points.
Mark these using a vertical (N -S) chalk,line on the
center of the rafters.
• Spacing may vary depending upon project specific
structural requirements; i.e. high snow and wind
load areas may require lesser bracket spacing in
the E -W axis vs. the maximum spacing. Max spacing
is 48" for portrait orientation and 72" for landscape
orientation. Consult project layout diagram for
project specific bracket spacing on the roof.
• Install Rock -It Mounts to predetermined mount
spacing.
• The array skirt sections are the width of a typical
60 cell module — use the array skirt as a guide to
lay out module placement.
Note: The distance between the rows of mounts is calc.-jlated by the module dimension N -S plus 1. 3/8"
(35mm). Lag screw should be Installed as close to center of exposed shingle as possible.
GreenFasTen FLaSHinG insTaLL
1 Locate the rafters and snap horizontal and vertical lines to mark the installation
position for each GreenFasten flashing.
2 Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPD..M mastic.
3 Insert the flashing so the top part.is under the next row of shingles and pushed far
enough up slope to prevent water infiltration through vertical joint in shingles. The
leading edge of flashing must butt against upper row of nails to prevent turning
when torqued.
4 Line up pilot hole with GreenFasten flashing hole.
Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed
hole in the flashing and into the rafter.
Torque: The range is between 100-140 torque inch -pounds depending on the type
of wood and time of year. The visual indicator for proper torque is when the EPDM
on the underside of the bonded washer begins to push out the sides as the washer
compresses. If using an impact wrench to install tie fasteners be careful not to over
torque the fastener. You may need to stop and use a ratchet to finish the install.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SYSTem inSTaLL
1 Install EcoFasten Solar Flashing with Rock -It Mounts
Follow GreenFasten Install instructions for flashing and bracket install on composition shingle roofs.
Optimum vertical distance between lag bolts is 13/8" plus module dimension.
Set mounts on eave most row so that the Rock -It Pedestal is on the South end of Rock -It Slide. (ex. image 1)
Set mounts on all upper rows so that the Rock -It Pedestal is on the North end of Rock -It Slide. (ex. image 6)
2 Install Array Skirt to Eave Mounts
• Install array skirt starting on west side of array and move east.
3-4 Attach Couplings to Array Skirt
Tighten the west most array skirt bolt on coupling first.
When tightening the east bolt the array skirt sections will be drawn together.
5 Align and Straighten First Row of the Rock -It System with Array Skirt
Use North-South adjustment of the Rock -It pedestal to straighten array skirt.
Tighten screw on side of Rock -It Pedestal to secure it to the Rock -It Slide.
Adjust Flange Level Nut to level the system (optional - can be leveled during or after installation)
Install 1 st Row of PV Modules
6_7
Slide Rock -It Mounts that are upslope down to engage top of first module.
Note: Make sure cable tray is facing upslope.
Torque 1st and 2nd row of mid -clamps on Rock -It Mounts and Rock -It Couplings to 150 in -lbs.
Note: Torque setting may vary according to module manufacturer.
Install Balance of PV Modules
8_9
Secure wire and electrical components in built in wire tray on Rock -It Mounts and Couplings.
ROCK—IT Install next row of panels and torque mid -clamps to secure modules.
SYSTE N/r Repeat install for all remaining rows of modules.
10 Level the Rock -It System
When assembly is complete, level the entire system by adjusting Flange Level Nuts.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
IGrounDinG LUG insTaLL
Necessary Components:
- Burndy CL50-1 TN Ground Lug (UL Listing #KDER.E9999)
- 14 AWG - 4 AWG Copper Ground Wire
- 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS)
- 8-32 Serrated Flange Nut (300 Series SS)
- . 11 /32" and 1/4" wrenches or ratchets/sockets
1 The Ground Lug is installed into the T slot on the Rock -It Mount.
2 Slide the Flange Head Bolt on the Ground Lug into T slot on Rock -It Mount.
3 Tighten Flange Nut/Bolt.
4 Place wire in Ground Lug channel and tighten setscrew to complete assembly.
jBonDInG ASsemBLY anD BonDInG PATH
Bond Path
Grounding Lug
- Equlp
Condmuctor ent.Grounding
(EGC}
generapy to earth
ground
Rock -It Coupling
Rock -It Mount
Integrated Bonding .
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
THermaL EXPansion anD BonDinG
A thermal expansion gap is
required per each continuous
100' length of modules.
Omit a coupling and leave a 2"
gap in the array skirt and also
between the modules at that
point.
BraCKeT SPacinG
Portrait Orientation
— Bond Path
Landscape Orientation
IS Wounding Lug
cEqwp d1�
=1Y to earth
m Rack -It Coupling
■ Rock -It Mount
Maximum bracket spacing in Maximum bracket spacing in
portrait orientation is 48" OG landscape orientation is 72" OC.
Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load
areas may require lesser spacing E -W than the maximum.
sTaGGereD LaYOUT I canTlLever am oFFseT
Staggered Mounting Points
. Rock -It Mount -Rock-It Coupling Cantilever: Maximum cantilever is 25% of module width. For portrait
orientation installations, check layout prior to installing.
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow
factors (roof obstacles, shading, ecc.) other layouts are required. loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SYSTem
• Fastest, easiest to level system on the market
• ETL listed to UL SUB 2703
• Class A Fire rating with Type 1 modules
• Integrated electrical bonding
• SIMPLE- only 3 components
• Fixed wire management tray
• North-South adjustability of up to 4'
• Only one tool required (1/2" deep well socket)
.
Max No. of Panels
300 Modules per ground lug
Materials
300 Series Stainless,
6000 Series Aluminum
Max System Voltage
1000VDC
Coating
Black Andodization/Mill Finish
Class A Fire Rating
With UL 1703 Type 1 Rated
Lug Specifications
Burndy CL50-1 TN Ground Lug
Modules
(UL Listing #KDER E9999)
Leveling Range
3-4"
Ground Wire
14 AWG- 4 AWG Copper
Per above Lug spec.
Ground Wire
Rock -It Slide Range
4"
Max Module Size
64.96"(1650mm) x
39.05"(992mm) x 2"(50mm)
Min/Max Roof Slope
5:12/12:12
Max Downforce/Uplift Rating
45 PSF
Max Anchor Spacing
72'
Rock -It Mount Load Rating
547lbs with Single 5/16" Lag 3.0
Safety Factor
Skint Box QTY
6 units
Slide Fastening Hole
5/16" diameter
Mount Box QTY
12 units
Module Cantilever
Lesser of 25% Width, or Module
Installation Manual
Coupling Box QTY
12 units
Warranty
10 Year Material and Workman-
ship
Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC
Standards: UL 2703, UL 1703
�Mtear�
man
<mil o 0 flus
www.ecofastensolar.com
oC e
IEco Fasten Solar
info@ecofastensolar.com
877-859-3947
solar -•. m.
SolarEdge Single Phas
For North America
SE3OOOA-US / SE38OOA-US / SHOOO1t
SE76OOA-US / SE10000A-US / SE114O1
16
a
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance
Superior efficiency (99%)
Small, lightweight and easy to instal! on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA -GERMANY •I'rALY-FRANCE-JAPAN •CH:NA-AUSI'RA'LIA I-IF.NEIHERLANOS ISRAEI www.solaredge.us
solar=ee
Single Phase Inverters for North America
SE3000A-US/SE3800A-US/SE500DA-US/SE6000A-US/
SE7600A- US/ SE10000A-US/SE1140OA-US
_ SE300DA-USjSE3800A-US
i SESOOOA-US iSE6000A-USISE760OA-US ; 10000A- US SE111ROA-US
- - - - -- - — —
OUTPUT
_
Nominal AC Power Output -
3000
3800 r_^ 5000 1 6000 7600 1 9980 @ 209V
11400
VA
100,0,0, @2404
Max. AC Power Output
3300
4150 5400 @ 208V
1 6000 1 8350 10800 @ 208V
12000
VA
� saso @zany
i � iD9sq @�agv
AC Output Voltage Min. -Nom. -Max.("
183 - 208 - 229 Vac
t ✓
AC Output Voltage Min: Nam: Max.n1 11✓
I
i I
211-240-264 Vac
I
' ✓
,
AC Frequency Min: Nom: Max.lil
59.3 - 60 - 60.5 (with
HI country setting 57: 60: 60.5)
H:
Max. Continuous Output Current
12.5 16
24 208V I
25'
I' 32 '...48 @
47.5
A
I
l 21 24ov
....... 4 2 240V.. -f
I
GFDI Threshold
t
A
Utility Monitofmg, Islanding Protection, Country Configurable Thresholds - - Yes I
_. _ _ .. . — -
Yes
IN PUT
- - - - --
-
Recommended Niax. DC PowerIll-
(�Ct
3750 i 4750 6250 �- 7500 I 9500 12400 1
14250
W
Transformer -less, Ungrounded
Yes
Max. Input Voltage
5110
Vdc
Nom. OC Input Voltage
32S @ 2118V / 350 @ 240V
Vdc
Max. Input Correntitl
P 1
1.6.5 (d 208V i 33 @ 208V I
9.5 13 lit 2.7 34.5
Adc
15.5 (� 240V 30 5 @ 240Vi
I
Max. Input Short Circuit Current
45
Adc
Reverse -Polarity Protection
yes
Ground -Fault Isolation Detection
600k -r Sensitivity
Maximum Inverter Efficiency
97.7 I 98.2 98.3 98.3 98 98 98
%
CEC Weighted Efficiency
i t I
97 @ Z08V
97.5'- 98 9798.5. @ 208V 97.5 975 ,
.@
Y6
I
Nighttime Power Consumption
r
_ _ < 2.5 <4
W
_ADDITIONAL FEATURES_
Supported Communication Interfaces
RS485, RS232, Ethernet, ZigBee (optional)
Revenue Grade Data, ANSI C12.1
Optional'
Rapid Shutdown -_ NEC _2014 690_.12
- _ Functionality enabled when SolarEdge rapid shutdown_ kit is installedal !
STANDARD COMPLIANCE-
—� �^
-
i�fetY
_ -_ ^� U1.1741.1.11,16998,1.11.199 8 , CSA 22,2
Grid Connection Standards
IEEE1547
Emissions_
- FCC partly class
INSTALLATION_ SPECIFICATIONS
_0
AC output conduit size / AWG range
f _ _ _
_ _ _ _ - _ 3/4" minimum / 16 6 AWG 3/4" minimum / 8.3 AWG
OC input cgnduitsize / lfof strings /
1
AWG range
3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-2 strings / 14-6 AWG
Dimensions wlth Safety Switch
30.S x 12:5 x 7 /
305 x 125 x 7.5 /
in/
(HxWxOJ
775 x -315-x 172
30.Sx12.5x10.5/775x315x260
Mx 315x191
mm
Weight with Safety Switch I
S1.2./23.2
S4.7/ 24.7 88 A / 40.1
Ib / kg
Cooling
Natural Convection Fans (user replaceable)
Noise
< 25 < SO
dELA
Min. -Max. Operating Temperature
Range
-13 to +140 / -25 to +60 (-40 to +60 version available(0)
F /'C
Protection Rating
NEMA 3R
I" For other regional settings plasm contact SolarEdge support
016kW and lower: Limited to 135%ofAC power; 7 6kW and higher: limited to 125% for locations where the yearly avenge high temperature Is above 777/25'C end to 135% for location. whom It Is below 77'F/25'C
For detailed information, refer to fdte�tmde.adf
Is' A hlghercumerd source may be used; the inverter will limit its Input current to the values stated
Revenue grade inverter P/N: SExxxxA-US000NNR2
ts' Rapid shutdown kit P/N: SE1000-RS0-Sl
�a' -40 version P/N: SExxxxA-U5D00NNU4
solar:
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P400 / P405
PV power optimization at the module -level
— Up to 25% more energy
— Superior efficiency (99.S%)
— Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
— Flexible system design for maximum space utilization
Fast installation with a single bolt
— Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - ifALY - FRANCE - JAPAN - ChINA - ISRAEL - AUSI'RALIA www.solaredge.us
• •
So
I a r' • •
SolarEdge Power Optimizer
Module Add -On for North America
P300 / P400 / P405
600 ! P400 I P405
-
(for 72 & 96 modules) �' (far thin film rnodulesl
----- - -- _. - --
-
INPUT•cell
Rated Input DC Powers" _.
300 400 405
W
Absolute Maximum Input Voltage
1
(Voc at lowest temperature)
48 80 I 125
Vdc
,
MPPT Operating Range
S - 48 B-80 12.5-105
Vdc
Maximum Short Circuit Current (Isc)
{ 10
Adc
Maximum DC Input Current
12.5
Adc
Maximum Efficiency
99.5
%
Weighted Efficiency
98.8
%
OvervoltageCategory___•__•
� _ __ ___ II _ _ _�
_
OUTPUT DURING OPERATION (POWER OPTIMIZER
-
CONNECTED TO OPERATING SOLA_REDG_E INVERTER)
�- -
Maximum Output Current
15
i Adc
Maximum Output Voltage _
60 j,� 85
Vdc
_ _ _ _ __ _
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
_____ - - _ - _ _ __ -_... _ ...--_-_.__ ----- --- ----- -.
^
Safety output Voltage per Power,Optimize�
1
-
I Vdc
STANDARD COMPLIANCE
EMC
FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
t
Safety
I IEC62109-1(class II safety), UL1741
RoHS _ _ �.
_ _ _ Yes
INSTALLATION SPECIFICATIONS—
�- — - --
- - -
Maximum Allowed System Voltage
! 1000 i
Vdc
Pxxx-2 series
r 141 x 212 x 40.5_ / 5._5.5 x 8.34 x 1.59
s mm / in
Dimensions (W x L x H) ;
Pxxx-5 series
129x152x27.5/ / s 128x152x48/
129x152x35
I I
! mm/in
5x5.97x1.08 5x5.97x1.37. 5x5.97x1.89
Weight (including cables) Pxxx.2 series
f
.95.0./.2.1.
gr / Ib
f
Pxxx-5 series
7-70/1.7 1 930/205 j 930/2.05
gr / Ib
Input Connector
MC4 Compatible
i
Output Wire Type / Connector
Double Insulated; Amphenol
Output Wire Length
0.9S/3.0 j 1.2/3.9
m / ft
Operating Temperature Range
-40-+85/-40-+185
I 'C/'F
j Pxxx-2 series
+ IP65 / NEMA4
Protection Rating
P xxx 5 - series
IP68 / NEMA6P
Relative Humidity
0-100
'Yo
ni Rated STC power of tho module. Module of up to t,%power tolerance allowed.
PV SYSTEM DESIGN USING
A SOLAREDGE INVERTER("
SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
Minimum String Length
1
(Power Optimizers)
t 8 10 18
Maximum String Length
25 25 50
(Power Optimizers)
Maximum Power per String
± 5250 6000 12750
W
Parallel Strings of Different Lengths
or Orientations
Yes
"' It Is not allowed to mix P405 with P300/0400/P6i10/P700 in one string
I
KM
RALIN 0
BUSTER
1
1
�1
arra
W�et�m C
U10a Flexible Roof Tile Adhesive/Sealant
PYTVVenft Roof &Oa rs and ffimb in rile'
ROOF TILE I SHINGLES) SHEET METAL I FLASHING I VENTS I GUfIERS I TRIMS I NEW CONSTRUCTION I REPAIRS,
Roofs areon the front line .in preventing water intrusion p High -Grade Polyurethane Formulation
and' are subjected Jo- the, most extreme wind. and weather'
D Permanently Secures Roof Tile
conditions. To prevent roof damageand leaks, an adhesive/
PNon-Shrinking, Permanently Flexible
sealant must be a standout performer. RainBuster 850
Ultra -Flexible Roof Tile. Adhesive/Sealant' is specified by
b UV Resistant; Hexes to Prevent Broken Tiles
leading builders�and trusted by quality -minded contractors..Ib,Withstands
Extreme Wind, and foot Traffic
to prevent. roof. leaks.. Unlike traditional roofing cements:
D Seals Roofing Joins including Flashing
and mastics, RainBuster 850 offers a high-grade polyurethane
* Withstands Extreme Weather & Temperature
formulation, permanent flexibility and -powerful adhesion.
V, Non -Sag to Prevent Tile Slip
When used as a roof the adhesive, RainBuster 850 shines
D Adheres to Damp Surfaces,
as it flexes with hurricane force wind uplift, foot traffic, and
I* Paintable (See Painting Section)
seismic activity to prevent,broken tiles. When applied to
p Non -Flammable
flashing•, vents and' gutters, RainBuster 850 permanently
p VOC, CARE, and AOMD Compliant
seals joints to effectively divert water away from the home.
D Lifetime Warranty
The Ultimate Roof Tile Adhesive/Sea
0 o D
RAIN'
BUSTER
v
Ldp Ind s ri ,Inc. • 5010Us%a c 6 + v .tope dustna .co
I
It
"IN Ultra Flexible Roof Til fF'�P��`°N
BUSTER Adhesive/Sealant°"'�
~y �y Tield Proven to Prevent Roof Leaks
DESCRIPTION
TILE -TO -TILE BONDING
{ RainBuster 850 Ultra -Flexible Roof Tile Adhesive/Sealant ,, RainBuster 850 is ideal for adhering roof tile -to -
is the high quality standard in the prevention of roof tele in valley, ridge, hip, rake and general root the
leaks. Its technologically advanced polyurethane formu- installation. Secures cut files when mechanical
lation has been specifically designed to provide roofing fasteners cannot be used. RainBuster 850 provides
application solutions. RainBuster 850 performs equally may; *. additional protection against wind uplift, seismic
well when used as a the adhesive or as a sealant onactivity, and the damage. Prevents file chatter.
flashing, vents, and other roof penetrations. RainBuster " " �• RainBuster 850 seals nail entry points created
850 Is ideal for specifying as a multi -use roofing adhe- during the Installation. RainBuster 850 flexes to
sive/sealant. it is ideal for both new construction and l stay bonded and prevent broken the and roof leaks.
repairs.
PACKAGING, SHELF LIFE & STORAGE
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is available in standard 300 ml cartridges
(packaged 24 per case) and 592 ml sausage tubes
(packaged 12 per case). The shelf life is 12 months.
Store in a cool, dry place below 80°F for maximum
shelf life.
AVAILABILITYAND COST
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is competitively priced and widely available.
Please contact Top Industrial, Inc. at 800-473-1617 or
see www.topindustrial.com for a supplier nearest you.
AUTHORIZATIONS
Masts or exceeds:
ASTM C920 Type S, Grade NS, Gass 35, use NT, A and M
Federal Specification TT -S -00230C (COM-NBS)
Type Ii, Class A
Canadian Specification CAN/CGSB-19,13-M87
ENVIRONMENTALLY FRIENDLY
• Qualifies for LEED Credit from U.S. Green Building
Council: l pt EO Credit 4.13
• Qualifies for NAHB Green Build Credits:
5 pts Global Impact Credit 7.1.3
• VOC Compliant under AQMD and CARB
LIFETIME WARRANTY ' fmft* seals seams in gutters, gutter assemblies, and downspouts.
Top Industrial warrants this adhesive to perform as dimpiteadSilrwe Adheres shingles and supplements mechanical fasteners.
described on its package and associated data sheet for ' yQpBy seamsr,
a period of 100 years from the date of purchase. See
next page for further warranty details. ~Supplements ts mechanical fasteners and seals ins• Can significantly reduce vibration nese.
81rArlkywantrSea ls teas in fell and undalaymenl Bridge entire tear and tad as necessary.
YYtSwOm fatllAprrl: Adheres to to damp surfaces. Remove standing water prior to application.
FLASKING LAP JOIWS
RalnBueter 860 Is Ideal for sealing wed lap jdnIB
- ,
•.f� •",i
where two lengths or flashing meet such as in valleys.
4 51x.:: y
.'� �+•. I {„ 3� T
UnBuO�IVr 151)to maintain
1Nxes a permanently
bonded wales" seal For best results, apply a
continuous 1/2" bead to both the inside and.
s
outside of the joint. Tool the outside joint bead
as necessary (see application and tooling sec-
tions). Available in the multiple colors and
paintable (see painting section).
-
ROOF—MWALL FLASHINGS
RainBuster 850 Is ideal for use where flashing
terminates at walls and chimneys. RainBuster 850
is
provides outstanding adhesion to both metal and
common exterior wall surfaces. RainBuster 850
flexes b maintain a watertight, seal. For best
-'
results, apply a continuous 1/2' bead to both
the inside and outside of the joint. Tool the out-
side joint bead as necessary (see application
and tooling sections). Available in the multiple colors
and paintable (see painting section).
VENTS AND CNIAWEY CAPS
RainBuster 850 seals'jards in vents, chimney caps
^ and other roofing envelope penetrations. Also secures
vend structures to underlying !rases. RainBuster 1350
flexes to maintain a watertight seal. For best results,
apply a continuous 1/2" bead to both the inside
+ and outside of the joint Tool the outside joint
` bead as necessary (see application and tooling
sections). Available In the muftiple colors and
paintable (see painting section). -
LIFETIME WARRANTY ' fmft* seals seams in gutters, gutter assemblies, and downspouts.
Top Industrial warrants this adhesive to perform as dimpiteadSilrwe Adheres shingles and supplements mechanical fasteners.
described on its package and associated data sheet for ' yQpBy seamsr,
a period of 100 years from the date of purchase. See
next page for further warranty details. ~Supplements ts mechanical fasteners and seals ins• Can significantly reduce vibration nese.
81rArlkywantrSea ls teas in fell and undalaymenl Bridge entire tear and tad as necessary.
YYtSwOm fatllAprrl: Adheres to to damp surfaces. Remove standing water prior to application.
9 i A
APPLICATION: Easy to apply with conventional caulking equipment. Application temperature range: 20F —120F. it application air temperatures are below 40F, con-
dition product at 7OF prior to using for best results. Cut tip at a 45 -degree angle. Location of cut will determine desired bead thickness. Puncture seal. Apply sealant to joint
Typically, minimum 3/8"-1/2" beads should be used for proper bonding and sealing. Fill joints in continuous beads from deepest point and avoid overlapping of sealant to
prevent air entrapment. Adhesive/sealant should wet the joint wall surfaces. With lap joints, apply adhesive/sealant to both inside and outside of joint for best results. I
Adhesive/sealant provides 1-3 hour working time before skinning. Adhesive/sealant cures with exposure to normal atmospheric moisture with full cure in 1-3 days depending 1
on humidity. May be used on damp surfaces; take steps to remove standing water. For best results, use opened cartridges and sausages the same day.
APPROPRIATE SURFACES: RainBuster 850
is appropriate for use in new construction
and repairs on a wide range of common
roofing materials including concrete, day,
slate, composition, fiber -cement, asphalt
saturated shingles, masonry, morW,metals
Including galvanized, aluminum, and
copper, u ndedayment and felts. plastics
Including PVC, vinyl, fiberglass, nails, and
wood.
PREPARATION: For best adhesion results,
surfaces should be dean, and free from
dirt, dust, ails, release agents, standing.
water, old sealants, or other contaminants.
Dust and loose particles should be blown-
off
lownort surfaces.
FIELD PRETEST: Due to the varied nature
of construction substrates, field-test
adhesive/sealant on actual surfaces prior
to beginning work User must determine it
results including adhesion are acceptable.
70MM B required, lolling is remm mended
within 20 mimrles after application. Tooling
should be done in one continuous stroke.
Techniques using solvents or soaps are not
recommended. N masking, remove tape
Immediately after tooing.
CLEAN UP: Clean hands safely with
RainBuster Top Towels (citrus wipes).
Mineral spirits and other commercial
solvents such as xylene, toluene, or
methyl ethyl ketone (MEIQ may be used
to dean up excess smears and tools. The
use of solvents may be hazardous to your
health. Keep away from open flame and
use in well -ventilated area. Follow
solvent manufacturer's instructions.
Cured adhestve%alant is difficult to
remove and must be done so by abrasion
or other mechanical means.
PAINTING OVER RAINBUSTER 850: For
best results, apply paint over RainBucter
850 adhesive/sealant 72 hours after
application. High quality 100% acrylic
paints and primers are recommended.
Many mofing specific spray paints are
acceptable. Avoid the use of oil base
paints as they may exhibit a slow/non-
curing condition when in, contact with
adhesive/sealant: Paint when weather
and temperature conditions meet paint
manufacturer requirements. Feld pre-test
for suitability of paint and painting
process Is required. Contractor must
determine suitability. Consult Top
Industrial for further information.
MAINTENANCE No maintenance should
be needed. If adhesive/sealant becomes
damaged, remove damaged portion. Clean
surfaces in damaged area, and repair with
fresh RainBuster 850.
PRIMING PRIOR TO APPLICATION:-
Generally,
PPLICATION:Generally, priming is not required. If
adhesion pretest Is unacceptable, consult
Top industrial for recommendations.
APPLICATION OVER GLAZED, PRE-
PAINTED, OR PRE -PRIMED SURFACES:
Glazed, pre -painted and pre -primed
surfaces_ typically do nothave the adhesive
quality or flexibility of Rainkster 850
adhesive/sealant. Lack of adhesive/sealant
contact with raw substrate may inhibit
ability to maintain bond and halal. Glaze,
paint or primer may pull away from raw
substrate with joint movement
USE WITH ASPHALT BASED SELF -
ADHERED FLASHING (A.K.A. SBS modi-
fied asphalt 8 bituminous materiaQ:
When used appropriately, RainBustor 850
can be used successfully with asphalt -
based flashings. Unlimited contact is
acceptable between adhesive/sealant
and the permanent polyethylene/plastic-
based facer side of selt-adhered asphalt.
flashings. Steps must be taken to minimize
contact with the adhesive side of asphalt
flashings. Plasticizers in adhesive/sealant
may accelerate the normal molstardng and
softening of asphalt that occas with heat.
Do rat apply adhesive/sealant directly b
adhesive asphalt side of flashing. Do not
apply adhesW side of asphalt flashing
directly over adhesivelsealard. Remove
excess sealant prior to application of
adhesive asphalt side of flashing. User
must determine suitability through field.
pretest Consult Top Industrial for further
information.
LIMITATIONS: Suitability for each intended
use must be determined by the user using
the intamnation found in this data sheet and
an application pretest
• Not for use over standing surface water
or surface frost
• Not designed to replace use of
mechanical fasteners.
• Not for use where subjected to constant
water immersion.
• When pained, user must determine
paint suitability. See"Painting" section for
detailed limitations.
• When used with asphalt -based self -
adhered flashings, user must determine
suitability through field pretest See "Use
With Asphalt" section for detailed
limitations.
• Do not cure in presence of curing
silicone sealants. This may interfere
with RainBuster 00's curing process.
• Avoid sealant contact with advent
cleaners during cure. This may Interfere
with RainBuster 850'a curing process.
PRECAUTION: Combustible vapor.
Uncured sealant may cause allergic skin
reaction and eye, skin and respiratory tract
Irritation. Keep away from sparks and
flame. Avoid contact with eyes, skin and
clothing. Avoid prolonged exposure to
vapors. Use only with adequate ventilation.
Wear protective clothing during handling.
Wash thdrouft after handling. KEEP OUT
OF REACH OF CHILDREN. See material
safety data sheet before use (contact Tap
Industrial or distributor).
FOR COMMUCTiOR AND INDUSTRIAL
115E BY DUALWO CRAFTSIiRAN.
FIRST AID: If inhaled, remove to fresh air.
If breathing is difficult, give oxygen and call
a physician. In case of contact with
uncured sealant, immediately flush eyes
with water for at least 15 mhatas and
wash skin with soap and water after using
RainBuster Top Towels (citrus wipes). Call a
physician 0 kW m persists. See material
safety data sheet for more detail
LIFETIME WARRANTY DETAILS: Top
Industrial, Inc. warrants this sealanVadhe-
sive to perform as described on Its pack-
age and associated data sheet for a period
of 100 years from the date of purchase.
Upon proof of purchase, Top Industrial's
sole liability, expressed or implied, shall be
to replace sealant/adhesive proven defec-
tive and is limited to the stated selling
price. This warranty is not transferable
from the original purchaser. in no evert
shag Top Industrial be Gable for conse-
quentiai or incidental damages, resulting
from the use of its sealant products.
WK
BUSTER
96� 51-
vr„,„ •, rr � a
{ 6 �4.F� .• ..
ROOF ILE I SfRNGLFS i SHEET METAL I R ASNRiG I von I GOITERS I MM I NEW CONSIMMON I REPABg.S
AVAILABLE COLORS
w
Corel Terra Cotta Tan Gray (Sone) Brown Black
)
/
300 ML CARTRIDGES
APPROXNTIATE LINEAR FEET PER CARTRIDGE
BEAD WIDTH, INCITES
1/4" 3/8" 1/2" S/8"
3/4"
7/8"
1"
1/8"
49.6 33.1 24.8 20.0
16.5
14.2
12.4
1/4"
24.8 20.0 12.4 10.0
8.3
7.1
6.2
u
—
3/8"
— 11.0 8.3 6.6
5.5
4.7
4.1
6.2 5.0
4.1
3.5
3.1
Kl.,".Try
Jlfa,le t
�� usn
For more than 25 years,
Top Industrial's RainBuster
' brand has been trusted to prevent leaks in the building
t
pe and squeaks in Boor structures. Today that
runs deep - RainBuster is specified by the
on's leading builders and trusted by scores of
spected contractors.
The reason for the trust Is simple...
RalnBuster products and services outperform,
other brands in preventing leak and squeak
related call-backs.
PHYSICAL PROPERTIES
SkinTime..........................................................1-3 hours
CureTime..........................................................1-3 days
% Solids.......................................................96% to 99%
Paintable.........................................Yes — See limilamns
Sagor Slump...........................................................None
Clean-Up....................................................Citrus Cleaner
Shrinkage....................................................................NII
Chalking or Crazing,,,......;:.... ..; .......Nil
r PW.4L PERFORMANCE CHARACTERISTICS
Atter 7 days cure at 77 deg. F and 50% RH
Hardness (Shore A): ................................ 32 ASTM D 2240
Tensile Strength ......................Up to 250 psi ASTM D 412
Elongation........................................1400% ASTM D 412
Adhesion In Peel ........... _ .....................................>33 piw
........................................... T S-002.MASTM C 794
Stain & Color Change................................................None
.........................................TT-S-00230C/ASTM C 510
Ozone- Resislance ...............................................Excellent
Joint Movement Capability ..................................... ±35%
ASTM C719, 73°F cure / 730F cycling
W Resistance ........................Excellent - ASTM C 793-75
Water Resistance ................................................Excellent
WVM= BY:
'Product Data Sheet
. DU222RB
Safety Switch, 60A, 240VAC, Non -Fusible,
General Duty, 2 -Pole
by Schneider Eivco•Ic
List Price $353.00 USD
Availability Stock item: This Item Is normally stocked in our distribution facility.
Technical Characteristics
Wire Size
-
#10 to #2 AWG(AI) - #14 to #2 AWG(Cu)
Action
Single Throw
Ampere Rating
60A
Approvals -
UL Listed File Number E2875
Enclosure Type !� w T
Rainproof and SleeUlce proof (Indoor/Outdoor)
Enclosure Rating
NEMA 3R
Factory Installed Neutral
No
Ma>amum Voltage Rating
_ 240VAC—
Disoonnect Type _ _ T _ .
Non -Fusible r
Terminal Type
Lugs
Mounting Type
Surface -
Type of Duty
General Duty -
Number of Poles
2 -Pole --- - - - - -
Shipping and Ordering
Category
00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R
Discount Schedule
DE1A
GTIN —
00785901491491
Package Quantity
Weight _
4.7 lbs.
Availability Code
Stock Item: This item is normally stocked in our distribution facility.
Returnability
Y
Country of Origin W
— MX
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
® 2009 Schneider Bectric. All rights reserved. Schneider
'Electric