BMCH2016-041178-495 CALLE TAMPICO Ce
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
D 16 tF
BUILDING PERMIT
Application Number:
BMCH2O16-0411
Property Address:
52900 AVENIDA CARRANZA
APN:
773322008
Application Description:
SANTA CRUZ RESIDENCE / HVAC
Property Zoning:
co
{�,��J o
Application Valuation:
$15,500.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
LICENSED CONTRACTOR'S DECLARATION -
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 763937
CDate. ( `--'Contractor:►7
1- -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work'
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec: 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
Df the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5034539
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: ll i5 11l, Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
`.I Date: III/Xi-11C.- Signature (Applicant or Agent): :�—�
D 16 tF
Owner:
W
CONSUELOSANTACRUZ
tz
52900 AVENIDA CARRANZA
,�,�,
0
LA QUINTA, CA 92253
co
{�,��J o
Z
CV
Lee
0.
a
Contractor:
C=)
oLli
Q
VOTTA ENTERPRISES INC DBA
COM RT A=
U
72248 NORTHSHORE ST STE 101
p
Q
THOUSAND PALMS, CA 92276
z
Q
CD
(760)320-5800
0
Llc. No.: 763937
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
Df the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5034539
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: ll i5 11l, Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
`.I Date: III/Xi-11C.- Signature (Applicant or Agent): :�—�
Application Number:
BMCH2016-0411
Property Address:
52900 AVENIDA CARRANZA
APN:
773322008
Application Description:-
SANTA CRUZ RESIDENCE / HVAC
Property Zoning:
Application Valuation:
$15,500.00
Owner:
CONSUELOSANTACRUZ
52900 AVENIDA CARRANZA
LA QUINTA, CA 92253
Date: 11/14/2016
Applicant: Contractor:
IE INC VOTTA ENTERPRISES INC DBA COMFORT AIR
31225 LA BAYA 72248 NORTHSHORE ST STE 101
WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276
(760)320-5800
Llc. No.: 763937
--------------------------=------------------------------------------------------------------
Detail: HVAC CHANGE OUT - 25 SEER/80AFUE SPLIT SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION.
PER 2013 CALIFORNIA BUILDING CODES
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306
0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$38.00
Total Paid for CHANGEOUT: $114.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$96.27
Total Paid for PERMIT ISSUANCE: $96.27
. ..
Bin.#
city..0 fLa Quints
Budding 8L Safety Division
P.O. Box 1504,78-495 Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
Building Pennit'Application'and Tracking Sheet
Permit #
Project Address: 52900 Avenue Carranza
Owner'sName:.Ricardo Santa Cruz
A. P. Number.
Address: 52900 Avenue Carranza
Legal Description:
Contractor: Comfort Air
City, ST, Zip: La Quinta, CA 92253
MMIM
Telephone:
Address: 4803 E Sunny Dunes Road
ProjectNscription: Replacb.4 ton A/C, coil, & 90,000 BTU
City, ST, Zip: Palm Springs, CA 92264.
Furnace
Telephone: 760-320-5800
State Lic. # : 763937
City Lie. #:
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
State Lic. #:ffw�i»
Name of Contact Person: Steven Schnierer
Construction Type:. ' Occupancy
Project type (circle one): New Add'n Alter Repair Demo
Sq.Ft.: #Stories:
#Units:
Telephone # of Contact Person: 818-73577876
Estimated Value of Project: $15,500.00.
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACKING
PERMfP FEES
Plan Sets
Pian Check submitted.Item
Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Calci.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
tad Review, ready for correctionstissue
Electrical
Subcoutactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'^' Review; ready for correctionslissue
Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr '
Date of permit issue
School Fees
Total Permit Fees
STATE OF CALIFORNIA
ALTERATIONS - HVAC
r' T
CEC-CFIR-ALT-04-E Revised 03/15 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF1R-ALT-04-E
Alterations - HVAC CZ 2, and 8-15 (formerly CF -IR -ALT -HVAC) (Page 1 of 1)
Site Address:
Enforcement Agency:
Date Prepared:
Permit#:
52900 Avenue Carranza
City Of La Quinta
November 14, 201
Equipment Type
Equipment Efficiency
New Ducting, Plenums, Lineset:
Conditioned
Thermostat
Required R -value
Floor Area (sq ft)
❑ Packaged
REvaporator Coil
80%AFUE
COP
❑ R-6 (CZ 2, 8-13) Ducting
Served by system
;Setback
System
Xcondensing Unit
25
❑ R-8' (CZ 11, 14, 15) Ducting
1,500 sgft
(If not already
Split System
❑ Compressor
SEER
HSPFpresent
❑ R-6 (all CZ's) Plenums
must
❑ Mini Split
❑ Lineset
EER
❑ R-5 or R7.5) Lineset°
be installed)
Furnace
❑ TXV
HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this
form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site.
R1. HVAC Changeout/Repair
Required Compliance Documents to be left on site for Final:
All Equipment,
CF111-ALT-02-E
Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)2 -HERS, MECH-25-HERS2
Compressor, TXV, Lineset,
CF3R: MECH-20-HERS, MECH-(23 or 24)-HERSZ, MECH-25-HERSZ
Air Handler/Furnace' (Can include new ducting)
Installer Requirement: Duct leakage [L15%, or < 10% to outside, or seal all accessible leaks), Air Flow z 300 CFM/ton, Refrigerant Charge.
Exempted from duct leakage testing if:
❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or
❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building
❑ 2. New HVAC System
Required Compliance Documents to be left on site for Final:
All new equipment and All New Ducts3
CF111-ALT-02-E
including Mini Split
CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERSZ, MECH-25-HERS2
CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERSZ, MECH-25-HERSZ
Mini Splits require CF1R-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS
Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow z 350 CFM/ton (or alternative), Refrigerant Charge
❑ 3. Ali New Ducts with Replacement
Required Compliance Documents to be left on site for Final:
All New Ducts3 and one or more of the following
CFIR-ALT-02-E
replaced: Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
Compressor, TXV, Lineset, Furnace
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
'Installer Requirement: Duct leakage < 6%, Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge
Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos
❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final:
New ducting but less than All New Ducts3 CFIR-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS
Installer Required to: Duct leakage (:L15% or, < 10% to outside or, or seal all accessible leaks)
❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc.
2 Heating only systems and Air Handler/Furnace changes do.not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25
3 All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the
dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material)
° R-5 (I" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter
with insulation as the following 1.5-2T-2%", 2.5-3T-2%", 3.5 to 4T-2%", 5T -4Y"
Contractor (Documentation Author's /Responsible Designer's Declaration Statement)
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document.
3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the
requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR).
4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or
system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR.
5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Date Signed:
License:
Steven Schnierer
1!�tulo-rl l'cZ,,f�
November 14, 2016
763937
Company:
Address:
City/State/Zip:
Phone:
Comfort Air
4803 E Sunny Dunes Road
IPalm Springs, CA 92264
1 760-320-5800
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300