Loading...
BMCH2017-0207&tp 78-495 CALLE TAMPICO C 4'-cv LA QUINTA, CALIFORNIA 92253:DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760).777-7011 INSPECTIONS (760) 7774153 Application Number: - BMCH2O17-0207 Owner: Property Address: 80772 SPANISH BAY STAN.YARBRO APN: r 775310015 121 PARK -PL Application Description: YARBO RESIDENCE / EVAP COIL CHANGE OUT PISMO BEACH, CA 92253 Property Zoning: Application Valuation: $380.00 Applicant: Contractor: SCOTT BARNETT BARNETT'S A/C 51390 AVENIDA NAVARRO 51390 AVENIDA NAVARRO LA QUINTA, CA 92253 LA QUINTA, CA 92247 (760)391-0350' Llc. No.: 936600 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 936600 Date Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its.issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division' 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not, intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of'sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to'construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt.under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). . Lender's Name Lender's Date: 6/2/2017 . WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the'following declarations I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person.in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO.THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S. FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application: 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicationbecomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of . work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): ' Date: 6/2/2017 Application Number: BMCH2O17-0207 Owner: Property Address: 80772 SPANISH BAY STAN YARBRO APN: 775310015 121 PARK PL Application Description: YARBO RESIDENCE / EVAP COIL CHANGE OUT PISMO BEACH, CA 92253 Property Zoning: Application Valuation: $380.00 Applicant: Contractor: SCOTT ,BARNETT BARNETT'S A/C 51390 AVENIDA NAVARRO 51390 AVENIDA NAVARRO LA QUINTA; CA 92253 LA QUINTA, CA 92247 (760)391-0350 ---------------------------------------------- -------------- Llc. No.: 936600 -.----------------- Detail: ---------------- FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT. BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVACCHANGEOUT - OTHER EQUIPMENT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT . QTY AMOUNT HVAC CHANGEOUT - OTHER EQUIPMENT PC 101-0000742600. 0 $38.00 Total Paid for CHANGEOUT: $76.00 DESCRIPTION ACCOUNT QTY AMOUNT Credit Card Fee 101-0000-43505 0 $3.21 Total Paid for Credit Card Fee: $3.21 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE • .10120000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 , $5.00 Total Paid for TECHNOLOGY'ENHANCEMENT FEE: $5.00 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) Project Name: hertel I Date Prepared: CF11R-ALT-02-E (Page 1 of 3) 2017-06-01 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name hertel 02 Date Prepared 2017-06-01' 03 Project Location 80772 spanish bay 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name hertel ' Dwelling Unit Conditioned .Installin a 07 Zip Code 92253 08 Floor Area (ft2) 2000 . SC System . CFA served I refrigerant Installing new SC Installing Installing Installing Identification or Number of Space by this SC 09 Climate Zone 15"" 10 Conditioning (SC) Systems in 1 Name Served System (ft2) this Dwelling Unit: component? ^1 .r .�+`A^"."" I F 1.4-1w,-- _— i..{ ....,.,.o- I !' .....k'i. -117-.% r--- e - el-- -w 8 F B. Space Conditioning (SC) System Information i In. ... ). 01 02 •' 03 ; 04 � 05 . ;� �..,.6 ems , 0 ..# �107 1,.. t :; "108 .m ,,9 0 10 , SIF i ski: Y wm' :wMw'3 }s!emyy aW1�+:.. f9 !A; ' T1s the SC -1-1 .Installin a 1-1, k.0 V ii L.110 C M. SC System SC System . CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area, by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 2000 Yes Yes No. No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020185105A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 16:54:47 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-01 16:55:03 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 30 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling . Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas No heating This field or This field or Central split Less than or System 1 furnace component section is not section is not AC Indoor coil SEER 14 Setback equal to 40 R-8 altered applicable applicable feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems y - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 10% leakage to outside; or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verificatioA required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >=.300 CFMper ton required when MCH -25 is required. Exceptions: - . - Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing;requirements. - Heating -only systems and Air Handler Furnace changes do not require ven ication of Air Flow MCH -23; or Refrigerant Charge MCH 25: -Existing duct systems constructed, insulated or sealed with asbestos Aare exempt from MCH=20 Duct{Leakage Testing -requirements. _w 1 l 111 Vt "1'V ,a ''� ; .: '� '"'�r'M• ' .,.X+x ...z+ .,..: i. ��,.®.:r r„r wya q.+ `*w:; '- cif ; ' �d . s;r. '.....A .."o E. Entirely New or Complete Replacement Duct,System, with or without Equipment Changeout (Sections 150.2(b).1Diia.and 150.2(b)1E, F) w This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC) This section does not apply to this project. Registration Number: 217-A020185105A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-06-01 16:54:47 Report Version: 2016.1.005 Schema Version: rev 10/16 HERS Provider: CalCERTS Report Generated 2017-06-01 16:55:03 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly,CF-1R-ALT HVAC)(Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: LIL��l�?iIGGGf/ Barnett, Scott J Company: Signature Date: BARNETT'S A/C 2017-06-01 16:54:47 Address: CEA/ HERS Certification Identification (if applicable): 51390 AVENIDA NAVARRO City/State/Zip: Phone: LA QUINTA CA 92253 E 760-391-0350 Responsible Person's Declaration statement,,. I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate-, of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions'Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications materials,'components, and manufactured devices for the building_ design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6.of the California.Code of Regulations. I y' re rte» 4. The building design features or system, design feati resd entified on this Certificate of Compliance are consistent with%the information -provided on othet,applicabiZTompliance documents, worksheets, ,app't ngp Y 4. oZ E calculations, plans and specifications submitted totheenforcement agency for approval with this building permit application. - • ( 't< a , I ;!:'a , i t '.� 8 ' lk . �; , ' yf i, ,. aw- ..:,o: 5. I will ensure that a registered copy of this Certificate of Compliance shall be,made available with the buildingpermit(s)„issued for, he building, and made availableto the enforcement agency for all applicable g inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the,builder provides to the building owner at occupancy. Responsible Designer Name: `F Responsible De'sig'ner Slgnature: V ! �j� LGGV Barnett, Scott Company: Date Signed: BARNETT'S A/C 2017-06-01 16:54:47 Address: License: 51390 AVENIDA NAVARRO 936600 City/State/Zip: Phone: LA QUINTA CA 92253 760-391-0350 Easy to Verify at CaICERTS.com Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider Est responsibility for the accuracy of the information. Q Registration Number: 217-A020185105A-000-000-0000000-0000 Registration Date/Time: 2017-06-01 16:54:47 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016. 1.005 Report Generated: 2017-06-01. 16:55:03 Schema Version: rev 10/16