12-1452 (AR)L__
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA,.CALIFORNIA 92253
Application Number: 12-00001452
Property Address: 50465 VERANO DR
APN: 777-240-011- - -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 7863
Applicant:
Architect or Engineer:
\" \X
-----------------
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Clas B License No.: 975443
n
Date: Contractor: _ _.-
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State .
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is oot intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(sl licensed
pursuant to the Contractors' State License.Law.).
( 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY.
I hereby affirm under penalty of perjury that [here is a construction lending agency for the performance of the.
work for which this permit is issued (Sec. 3097, Civ. C.). '
Lender's Name:,
Lender's Address:
LQPI'>IL\f IT
VOICE (760) 777-7012
FAX (760) 777-7011
° ,INSPECTIONS (760) 777-7153
Date: 3/11/13
Owner:
HAMER LIVING TRUST
50-465 VERANO DR.
LA QUINTA, CA 92253
Contractor:
FRONTIER WEST BUILDERS INC
139 BELLINI WAY
PALM DESERT, CA92:2
(760) 702-1098 ///o�
Lic. No.: 97544�3N/,
T r v. > s
I hereby affirm under penalty of perjury one of `the f011owing declarations:
�'-r� �A
I have and will maintain a certificate off consent to stfure for mor �rs�eompensation, as provided
for by Section 3700 of the LabortC\o6.4.4bNr the perfgeriiance oft wo kefor which this permit is
issued.j7fj
1 have and will maintain workers' compensation�nsurance, as fff ¢// y Section 3700 of the Labor
„a r a �..
Code, for the performance of the work for Wh,ch�this. pep it sued. My workers' compensation
insurance carrier and policy number are: 'v
Carrier EXEMPT Policy Number, EXEMPT
_ I certify that, in the performance of the work for wlii`h this permit is issued, I shall not employ any
person in any manner so as to become subject to tfie�?Kkers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Cp-, siZiTfl hwith comply with a provisions.
Date ,i Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS.($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of[his conn y to nter upon the above-mentioned pro coon purp
Date: 3 Signature (Applicant or Agent):
Application Number
12-00001452
Structure Information
Construction Type . .
. . . TYPE V, UNPROTECTED
Occupancy Type . .
. . . DWELLG/LODGING/CONG <=10
Other struct info
CODE EDITION 2010
FLOOD ZONE NO
PATIO SQ FTG
35.00.
---------------------------------------------------------------.-------------
IST FLOOR SQUARE FOOTAGE
35.00
Permit . . . BUILDING PERMIT
Additional desc .
Permit Fee
99.00' Plan Check Fee..
64.35
Issue Date
Valuation . . .
7863
Expiration Date
9/07/13
Qty Unit Charge
Per
Extension
BASE FEE
45.00
6.00 9.0000
-----------------------------------------------------------------------------
THOU. BLDG 2,001-25,000
54.00
Permit . . . . .
ELECT -.ADD/ALT/REM
Additional desc .
Permit Fee . . . .
37.98 Plan Check Fee
9.50
Issue.Date.-Valuation
. . . .
0
Expiration Date
9/07/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
35.00 ..0350
ELEC-NEW RES - 1 OR 2 FAMILY
1.23
20.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
15.00
15.00 .4500
-- -----------------------------------7----------------------------------------
EA ELEC DEVICE/FIXTURE >20
6.75
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . . . .
33.00 Plan Check Fee
8..25
Issue Date . . . .
Valuation
0
Expiration Date
9/07/13
Qty Unit Charge
,Per
Extension
BASE FEE
15.00
4.00 4.5000
--------------------- _ ------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
18.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee . . . .
18.00 Plan Check Fee
4.50
[,Qmpwrl�
Application Number. . . . . . 12-00001452
Permit . . . . . . PLUMBING
Issue Date Valuation
0
Expiration Date 9/07/13
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
------------------------------------------------------------------------------
Special Notes and Comments
35 sf PATIO CONVERSION TO LIVING AREA.
REMODEL STUDY, ADD NEW SLIDING DOORS AND
RELOCATE FIREPLACE. 2010 CODES. PER
ARCHITECT DESIGNED PLANS CHARLES GARLAND'
C11991.
-----------------------------------------------------------------------------
Other Fees .. . . . . . . . . BLDG STbS ADMIN (SB1473)
1.00
ENERGY REVIEW FEE
6.44
HOURLY PLAN CHECK
.271.25
STRONG MOTION (SMI) RES
.79
Fee summary Charged Paid Credited
----------------- ---------- ---------- ---------- ----------
-Due,
Permit Fee Total 187.98 .00 .00
187.98
Plan Check Total 8.6.60 .00 .00
86.60
Other Fee Total 279.48 .0 , 0 .00
279.48
Grand Total 554.06 .00 .00
554.06
Bin.#
;J
City. of La Qui(1td
Buitdin a Safe Division
g ty
P.O. Box 1504,78-495 Calle Tampico
[a.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: JC'� JC'
A
Owner's Name: -
Cr r
A. P. Number.
Address: O �6S
Legal Description:
Contractor.
City, ST, Zip:
Telephone: — "•`
i Address:
~ �3
Proje-ctDescription:
City, ST, Zi �,
^ �
� CF�Dn..f� .
Tele hon
p
-� i
State Lic. #: CityLic. #;
Arch., Engr., Designer
Address: 7 ,(�
C� l►� Ala OF 3It ►3
City, ST, Zip:
w:
Tel6phone: 760 3 3So28 Y `�
State Lic. #: / A _~
..;;;,✓�/»,su''��'.
Name of Contact Person:. �o
LAIMi Oki lD `20%•
Construction Type: Occupancy:' -
Project type (circle one): New Add'p Alter Repair Demo
Sq. Ft.: �" # Stories: #Units:
Telephone # of Contact Person:
Estimated Value of Project:
`
v CA 0 NOT WRITE BELOW THIS UNE
#
Submittal
Rcq'd
Recd
TRACKING
PERMIT FEES -
Plan Sets
3
Plan Check submitted
Item
Amount
Structural Cities.
O�
Reviewed, ready for corrections
1
Plan Check Deposit. .
Truss Cates.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
P
Plans picked up
Construction
Flood plain plan
Plans resubmitted.. wg
Mechanical
Grading plan
i" Review, ready for correctiio issue
1
Electrical
Subcontactor List
Called Contact Person
?
Plumbing
Grant Deed
Plans picked up
SALL
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
3rd Review, ready for correctionsfissae
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
'�f
Iq
vp cam,-r,P
6 /3— I2t-G/ rt,.�s�P�,f6..3•s w/W&
5¢n-444�l�s. �la
y 0 ,6-Cceivts rev.`s.tW� S:A' � • 2/i /i3.
2...:
The Management Trust
MONARCH GROUP DIVISION
December 26, 2012
LARRY & SUZANNE HAMER
80285 VIA TESORO
LA QUINTA, CA 92253
RE: Architectural Submittal for 50465 VERANO DRIVE
Account #755315
Dear Homeowner:
The Architectural. Review .Committee for -MOUNTAIN VIEW HOA -has reviewed and APPROVED your architectural
submittal for the installation of a glass door to the rear of home and adding about 50 sq.ft to the back of home, per the
plans submitted.
All construction must commence within 120 days of this approval letter. If construction has not been commenced
within the 120 days, such approval shall be deemed withdrawn.
ARC approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications
comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations
or restrictions. The ARC shall not be responsible for reviewing, nor shall its approval of any plans or design, be
deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving
such plans and specifications, neither the ARC, the Members thereof, the Association, any Member thereof, their Board
of Directors, any Members thereof, or the Declarant assumes any liability or responsibility therefore or for any defect in
the construction or improvement from such plans or specifications. As provided in the CC&R's neither the ARC, the
Association, the Board of Directors or the Association or any Members thereof, not the Declarant or Developer shall be
liable to any Member, Owner, Occupant, or other person or entity for any damage, loss or prejudice s uffered or
claimed on account of (1) the approval or disapproval of any plans, drawings, or specifications, whether or not
defective, or (2) the construction or performance of any work whether or not pursuant to the approved plans, drawings,
or specifications.
Your patience and cooperation with the architectural review process is appreciated. If you have any questions, please
contact the association at (760) 776-5100, Extension 333.
Sincerely,
On behalf of the MOUNTAIN VIEW HOA Architectural Review Committee
Heather Yslas I Association Assistant Manager
Jamie Hansen
The Management Trust - Monarch Group Division
Enclosures (1)
cc: Board of Directors
Unit File
39755 Berkey Drive, Suite A, Palm Desert, CA 92211
CONNECTING PEOPLE TO THE PROMISE I PH: 760.776.5100 FAX: 760.776.5111 .
www.managementtrust.com
March 1, 2013
Re: 50465 Verano Drive La Quinta, Ca. 92253
To whom it may concern,
As of March 1, 2013.on Property known as 50465 Verano Drive La Quinta, Ca 92253 WHITLEY5
CONI RUCTION is NO LONGER to be connected to this project in any manner. Please contact from
today forward property owners Larry and Suzanne Hamer on any matters dealing with this project.
Contact information
Larry Hamer (310) 756-2096
Suzanne Hamer (760) 861-6162
Sincerely,
Larry and Suzanne Hamer
MAR � 1-2013
CIV o of �p R�I�A ENi
E�ppM
m( D�
coMM��
TRS
a,
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
HAMER's RESIDENCE
50-465 VERANO DR.
LA QUINTA, CA 92253
Project Designer:
HAMER'S RESIDENCE
50-465 VERANO DR.
LA QUINTA, CA 92253
Report Prepared by:
ARMANDO CHAVEZ
GLS Architecture Group
74491 JONI DR SUITE #9
PALM DESERT, CA 92260
760 278.1840
RF %- Fy OF LA QUINTA
DEC 19 2012
BY:
Job Number:
2012 -GLS -032
Date:
12/17/2012
tJUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATL1J_t - -A:
4E- 4►�2.
00
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
Energ Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 9
EnergyPro 5.1 by EnergySoft Job Number: 'ID: 2012 -GLS -032 User Number: 5553
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
HAMER'S RESIDENCE
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration 11211712012
Date
Project Address
50-465 VERANO DR. LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,011
Addition
35
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 35 Altered
Slab Unheated Slab -on -Grade None 35 Perim = 0' New
Wall Wood Framed R-19 88 New
Roof Wood Framed Attic R-19 2,976 Existing
Slab Unheated Slab -on -Grade None 2,976 Perim = 0' Existing
Wall Wood Framed R-13 3,207 Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Left (NWJ 160.0 0.400 0.35 10.0 none Roll -down Blind or Slats New
Front (SVI9 22.5 0.710 0.73 none none Roll -down Blind or Slats Existing
Left (NIAQ 152.5 0.710 0.73 none none Roll -down Blind or Slats Existing
Left (NKK 18.0 0.710 0.73 none none Bug Screen Existing
Rear (E) 197.0 0.710 0.73 none none Roll -down Blind or Slats Existing
Right (SE) 44.0 0.710 0.73 none none Roll -down Blind or Slats Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location . R -Value Status
AC -1 Ducted Ducted Conditioned 2.1 Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro5.1 by Energ Soft User Number: 5553 RunCode: 2012-12-17T16:15:06 ID: 2012 -GLS -032
Page 3 of 11
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
HAMER'S RESIDENCE
Building Type ® Single Family ❑ Addition Alone
I ❑ Multi Family 0 Existing+ Addition/Alteration
Date
11211712012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Roof 35 has a U -Factor greater than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 35.0 ft' Exposed Slab Floor, 4.000" thick at ADDITION
HIGH MASS Design - Verify Thermal Mass: 2,976.0 W Exposed Slab Floor, 4.000" thick at EXISTING
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final*to be given.
Ener Pro 5.1 by Ene ySoft User Number. 5553 RunCode: 2012-12-17T16:15:06 ID: 2012 -GLS -032 Pa e 4 of 11
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
HAMER'S RESIDENCE
❑ Multi Family 0 Existing+ Addition/Alteration
12/17/201
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 8.51 8.22 0.29
Space Cooling 118.38 116.52 1.86
Fans 21.07 20.76 0.31
Domestic Hot Water 12.35 12.35 0.00
Pumps 0.00 0.00 0.00
Totals 160.32 157.85 2.47
Percent Better Than Standard: 1.5%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (SM 225 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (SK9 52 23
Fuel Available at Site: Natural Gas (NKK 1,896 331
Raised Floor Area: 0 (NE) 1,206 197
Slab on Grade Area: 3,011 (SE) 734 44
Average Ceiling Height: 12.0 Roof 3,011 0
Fenestration Average U -Factor: 0.63 TOTAL: 594
Average SHGC: 0.63 Fenestration/CFA Ratio: 19.7
REMARKS
ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION
FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY.
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentaAaccurateete.Documentation
Author
Company GLS Architecture Group12117/2012
Address 74491JONIDRSUITE#9 Name ARMANDCit
/State2i PALM DESERT, CA 92260 Phone 760278.ed Date
The individual with overall design responsibility hereby certifies that oposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company HAMER's RESIDENCE
Address 50-465 VERANO DR. Name'
City/State/Zip LA QUINTA, CA 92253 Phone Signed Li nse # Date
EnergyPro 5.1 by Energ ySoft User Number. 5553 RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032 Page 5 of 11
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
HAMER'S RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2/17/2012
OPAQUE SURFACE DETAILS
Surface U- Insulation - Joint Appendix
Type Area Factor Cz3vily Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
35 0.024-38 '
0
0 Altered 4.2.1-A21 (E=4.2. 1-A 13 ENTIRE HOUSE
Slab
35 0.73
0
180 New -, 4.4.7-A1
ENTIRE HOUSE
Wall
581 0.07 R-19
315
90 New 4.3.1-A5
ENTIRE HOUSE
Wall
30 0.0 R-19
225
90 New 4.3.1-A5
ENTIRE HOUSE
Roof
2,976 0.049
0
16 Existing' 4.2.1-A4
ENTIRE HOUSE
Slab
2,976 0.730 None
0
180 Existing _ 4.4.7-A1
ENTIRE HOUSE
Wall
383 0.102 R-13
315
90 Existing 4.3.1-A3
ENTIRE HOUSE
Wall
1,009 0.102 R-13
90
90 Existing 4.3.1-A3
ENTIRE HOUSE
Wall
690 0.102 R-13
135
90 Existing 4.3.1-A3
ENTIRE HOUSE
Wall
1,125 0.102 R-13
315
90 Existing 4.3.1-A3
ENTIRE HOUSE
Wall
218 0.102 R-13
315
90 Removec 4.3.1-A3
ENTIRE HOUSE
Wall
50 0.102 R-13
315
90 Removec 4.3.1-A3
ENTIRE HOUSE
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor
SHGC •
Azm . -Status
Glazing .T e .
Location/Comments
1
Window 160.0 0.400 NFRC
0.35 NFRC
315 New
2008 PRESCR. WDW P -D
ENTIRE HOUSE
2
Window 18.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear . -
ENTIRE HOUSE
3
Window 4.5 0.710 Default
0.73 Default
-225 Existing
Double Metal Clear-
ENTIRE HOUSE
4
Window 9.0 0.710 Default
0.73 Default
315 Existing
Double Metal Clear,
ENTIRE HOUSE'
5
Window 36.0 0.710 Default
0.73 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
6
Window 3.0 0.710 Default
'0. 73 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
7
Window 12.0 0.710 Default
0.73 1 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
8
Window 3.0 0.710 Default
0.73 Default ' 315 Existing
Double Metal Clear
ENTIRE HOUSE
9
Window 36.0 0.710 Default
0.73 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
10
Window 3.0 0.710 Default
0.73 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
11
Window 36.0 0.710 Default
0.73 Default
315 Existing
Double Metal Clear
ENTIRE HOUSE
12
Window 6.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear ` •
ENTIRE HOUSE
13
Window 8.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
ENTIRE HOUSE
14
Window 24.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
ENTIRE HOUSE
15
Window 12.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
ENTIRE HOUSE
16
window 1 54.0 0.710 Default
0.73 Default
I *901 Existing
1 Double Metal Clear
ENTIRE HOUSE
N
(1) U -Factor Type: 116-A = Default -Table from Standard;,FRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS •
ID
Exterior Shade Type SHGC
Window
H t' Wd
Overhang Left Fin ',Right Fin
Len H t LExt RExt Dist ',.Leh . H t Dist Len H t
1
Roll -down Blind or Slats 0.13
10.0 15.0
10.0 0.1 10.0 10.0
2
Roll -down Blind or Slats 0.13
3
Roll -down Blind or Slats 0.13
4
Roll -down Blind or Slats 0.13
5
Roll -down Blind or Slats 0.13
6
Roll -down Blind or Slats 0.13
7
Bug Screen 0.76
8
Bug Screen 0.76
9
Roll -down Blind or Slats 0.13
10
Bug Screen 0.76
11
Roll -down Blind or Slats 0.13.
12
Roll -down Blind or Slats 0.13 '
13
Roll -down Blind or Slats 0.13
-
s
14
Roll -down Blind or Slats 0.13
15
Roll -down Blind or Slats 0.13
16
Roll -down Blind or Slats 0.13
Ener Pro 5.1 by EnergySoft User Number: 5553 RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032 Page 6 of 11
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
HAMER'S RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family G21 Existing+ Addition/Alteration
Date
2/17/2012
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area U -Factor SHGC
Azm Status Glazing Type Location/Comments
17
Window 27.0 0.710 Default 0.73 Default
90 Existing Double Metal Clear ENTIRE HOUSE
18
Window 48.0 0.710 Default 0.73 Default
90 Existing Double Metal Clear ENTIRE HOUSE
19
Window 18.0 0.710 Default 0.73 Default
90 Existing Double Metal Clear ENTIRE HOUSE
20
Window 6.0 0.710 Default 0.73 Default
135 Existing Double Metal Clear ENTIRE HOUSE
21
Window 12.0 0.710 Default 0.73 Default
135 Existing Double Metal Clear ENTIRE HOUSE
22
Window 24.0 0.710 Default 0.73 Default
135 Existing Double Metal Clear ENTIRE HOUSE
23
Window 2.0 0.710 Default 0.73 Default
135 Existing Double Metal Clear ENTIRE HOUSE
24
Window 8.0 0.710 Default 0.73 Default
315 Existing Double Metal Clear ENTIRE HOUSE
25
Window 12.0 0.710 Default 0.73 Default
315 Existing Double Metal Clear ENTIRE HOUSE
26
Window 8.0 0.710 Default 0.73 Default
315 Existing Double Metal Clear ENTIRE HOUSE
27
Window 4.5 0.710 Default 0.73 Default
315 Existing Double Metal Clear ENTIRE HOUSE
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt REA Dist Len H t Dist Len H t
17
Roll -down Blind or Slats 0.13
18
Roll -down Blind or Slats 0.13
19
Roll -down Blind or Slats 0.13
20
Roll -down Blind or Slats 0.13
21
Roll -down Blind or Slats 0.13
22
Roll -down Blind or Slats 0.13
23
Roll -down Blind or Slats 0.13
24
Roll -down Blind or Slats 0.13
25
Roll -down Blind or Slats 0.13
26
Roll -down Blind or Slats 0.13
27
Roll -down Blind or Slats 0.13
Ener
Pro 5.1 by EnergySoft User Number.' 5553 RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032 Page 7 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
HAMER'S RESIDENCE
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
12/17/201
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered I Removed Volume Year Built
AC -1 ADDITION
35 420
EXISTING
2,976 35,712 2003
Totals 351 2976 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
AC -1 2 Central Fumace
78% AFUE Split Air Conditioner 9.7 SEER Setback Existing
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Coolin Duct Location R -Value Tested? Status
AC -1 Ducted Ducted Conditioned 2.1 ❑ Existing
13
11
13
WATER HEATING SYSTEMS
S stem Name
Qt .
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.58 n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C
0
.id
-°a (
a C
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
EnergyPro 5.1 by Ener Soft User Number: 5553
RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032 Page 8 of 11
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
HAMER'S RESIDENCE
Date
11211712012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -611 Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a :Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El 677-95 2000 when specified on the CF -1 R. Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fire laces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot tights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R=12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system; or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value.is indicated on the.exterior of the.
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water'systems >15 psi, meets the requirements of Standards Table
123-A.
§1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 0)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2012-12-17T16:15:06 ID: 2012 -GLS -032 Page 9 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name
Date
HAMER's RESIDENCE
11211712012
§150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructedwith materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a* coating that is water retardant and provides shielding from solar
-radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will -allow all pumps to be set or
programmed to run only during off-peak electric demand periocls.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p).
Residential Lighting Measures.
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is'no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2..,,
§150(k)3: The watta a of permanentlyinstalled luminaires shall be determined asspecified b 130 d .
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz. . ,
§150(k)5: Permanently installed night lights and night lightsintegral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder; OR shall be rated to consume no more than'five watts of power as determined by §130(d); and shall not contain a
medium screw-base socket. +`
150(k)6: Li hti - ng integral to exhaust fans, in rooms other than kitchens, shall meet-the alicable`re uirements of §150(k).
150(k)7: All switching devices and controls shall meet-the requirements of §150(k)7.
icacy.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently, installed lighting'in kitchens shall be high'efficacy.
EXCEPTION::Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), ora multi-scene programmable control system; and.all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per. linear-foot of"
illuminated cabinet.
EnergyPro 5.1 by EnergySoff User Number: 5553 RunCode: 2012-12-17716:15:06 ID: 2012-GLS-032 Page 10o 11
:i -, :i. - ...
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
HAMER'S RESIDENCE
11211712012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoR User Number: 5553 RunCode: 2012-12-17716:15:06 ID: 2012 -GLS -032 Page 11 of 11