BRES2015-0112i
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA92253
I
Twit 4',(P 0alitto
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. C23 License No.: 9047/188
Date: -,l Contractor/ e—v�t 1"Q
OWNER. -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that.requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carr' Policy Number: _
`f 1Pcertify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if.I should become subject to the
workers' compensation provisions of Section 3700 of the Labor C dl hall forthwith
comply with those provisions.
i
Date: -4`( 16 I Applican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO.
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the.'owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work _being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned/,rg operty for inspection purposes. �
Date W 6 Signature (Applicant or Agee)
Date: 6/16/2015
Application Number:
BRES2015-0112
Owner:
Property Address:
50585 VERANO DR
SUE AND ROBERT ANTOLEC
APN:
777240017
50585 VERANO DR
Application Description:
ANTOLEC RESIDENCE REMODEL ADDITION
LA QUINTA, CA 92253
�--=—�UJ
Property Zoning:
Ir.
Application Valuation:
$20,000.00
cm o
C�
Applicant:
Contractor:
1�2
,� •^ i
MIKE MENDOZA
DESERT CONTRACTING INC
I
L
P.O. BOX 692
43-695 NORTH JACKSON STREET��
-
DESERT HOT SPRINGS, CA 92240
INDIO, CA 92201
(760)534-3865
LIC. No.: 904718
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. C23 License No.: 9047/188
Date: -,l Contractor/ e—v�t 1"Q
OWNER. -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that.requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carr' Policy Number: _
`f 1Pcertify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if.I should become subject to the
workers' compensation provisions of Section 3700 of the Labor C dl hall forthwith
comply with those provisions.
i
Date: -4`( 16 I Applican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO.
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the.'owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work _being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned/,rg operty for inspection purposes. �
Date W 6 Signature (Applicant or Agee)
4NCIAL INFORMATIr
DESCRIPTION:
Y.. .: ACCOUNT:-..
,QTY.-
, AMOUNT
PAID
PAID DATE'
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
PAID BY .
METHOD r;;
. ;RECEIPT#
CHECK #
CCT D BY
.` ., DESCRIPTION .''
w ACCOUNT
QTY
= AMOUNT _
'PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$0.00
PAID BY. „ .
; METHOD,
RECEIPT #
CHECK #
~CLTD BY
Total Paid forAD01TION: $291.97 $0.00
DESCRIPTION'; t
°': ACCOUNT;,
QTY;
AMOUNT
PAID
PAID::OATE
HOURLY PLAN CHECK -.YES
101-0000-42600
1.5
$105.00
$0.00
PAID'BY
METHOD , : '. t.:
RECEIPT #
CHECK #
'CLTD BY `;
..,.,.DESCRIPTION
ACCOUNT
QTY:
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
• 101-0000-42600
0.75
$52.50
$0.00
PAID:BY x
METHOD,
S ,RECEIPT # .
F CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00
;r DESCRIPTION ;..
-µ ACCOUNT~%
QTY.
AMOUNT -° .
„ -PAID
PAID DATE:
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
x METHOD' rt
° RECELP,T #
CHECK #
CLTD BY; `
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION
;ACCOUNT ...
QTY
a' -:AMOUNT -
` PAID '.
PAID DATE
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
PAID BY a
METHOD,
, . RECEIPT #
CHECK #
CLTD BY
-DESCRIPTION ; ; K „,;
ACCOUNT
QTY
'g jAMOUNT
`;PAID h
PAID'DATE:
DEVICES, FIRST 20 PC
101-000042600
0
$24.17
$0.00
PAID BY., :.
METHOD .;",
RECEIPT #':: r.
CHECK #
CLTD BY
Total Paid for ELECTRICAL: $48.34 $0.00
DESCRIPTION
ACCOUNT
QTY .
� _` AMOUNT
PAID , `.
PAID DATE
FIREPLACE
101-0000-42400
0
$145.03
$0.00
PAID. BY
METHOD
; • RECEIPT #f•
CHECK #
CLTD BY
,'� DESCRIPTION
; : ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIREPLACE PC
101-0000-42600
0
$217.55
$0.00
PAID BY,.
METHOD
,RECEIPT#,
CHECK #`
CLTD BY
Total Paid forFIREPLACE: $362.58 $0.00
'DESCRIPTION
ACCOUNT , .QTY.'
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$12.09
$0.00
PAID BYMETHOD
x YRECEIT #
` CHECK #
CLTD BY
DESCRIPTION
ACCOUNTCITYx
•. AMOUNT.
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
$0.00
PAID BY;' ` 4
METHOD
RECEIPT # -
CHECK #
CLTD BY
Total Paid forPLUMBING FEES: $36.26 $0.00
DESCRIPTION
ACCOUNT-
QTY
AMOUNT
PAID'
PAID DATE
REMODEL, EA ADDITIONAL 500 SF '
•101-0000-42400
0
$21.75
$0:00
—PAID BY
' METHOD •
RECEIPT #'
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY,
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40
$0.00
s PAID BY ;
METHOD
RECEIPT # z
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
" AMOUNT
PAID
PAID DATE'.
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
PAID BY a r. ' _
METHOD
RECEIPT # t;
CHECK # ,
CLTD BY
DESCRIPTION
ACCOUNT.
TQTY
' '' AMOUNT ,
PAID
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$0.00
PAID BY
METHOD
RECEIPT # -
CHECK #
CLTD BY
Total Paid forREMODEL: $223.34 $0.00
DESCRIPTION
t ACCOUNT
QTY
AMOUNT e'
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$2.60
$0.00
PAID BY -
METHOD
; RECEIPT #
CHECK #
CLTD BY
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $2.60 $0.00
DESCRIPTIONACCOUNT
QTY
'AMOUNT. •
PAID
PAID DATE
DOOR/WINDOW, NEW, FIRST 1
101-0000-42400
0
$60.91
$0.00
PAID BY " `
' METHOD
" RECEIPT # `
CHECK #
CLTD BY
DESCRIPTION.
ACCOUNT.
QTY
AMOUNT-
PAID
PAID DATE
-DOOR/WINDOW, NEW, FIRST 1 PC
101-0000-42600
0
$59.46
$0.00
PAID BY
METHOD •
RECEIPT #
CHECK #
CLTD BY
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $120.37 $0.00
1
Permit Deta115 PERMIT NUMBER
i
�'".�. T,• ,. "
City of La Quinfa
BRES2015=01112
y
Description: ANTOLEC RESIDENCE REMODEL ADDITION
Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED
Applied: 3/31/2015 PJU
Approved: 5/6/2015 JJO
Parcel No: 777240017 Site Address: 50585 VERANO DR LA QUINTA,CA 92253
Subdivision: TR 30357 Block: Lot: 72
Issued:
Lot Scl Ft: 0 - Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $20,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
4/7/2015
Details: 31 SQ. FT. ADDITION, RELOCATE FIREPLACE WITH NEW GAS LINE, RELOCATE•AFCI OUTLETS, RELOCATE OLD WINDOW AND ADD NEW
SLIDING DOOR.2013 CALIFORNIA BUILDING CODE. .
Printed: Tuesday, June 16, 2015 10:51:43 AM 1 of 4' SYSTIMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME• ACTION DATE . COMPLETION DATE
NOTES
NOTE
JIM JOHNSON
4/7/2015
4/15/2015
PENDING STRUC CORRECTIONS
NOTE
JIM JOHNSON
4/15/2015
4/15/2015
STRUC RFC
PLAN CHECK COMMENTS
'
FROM CONSULTANT
JAKE FUSON
5/5/2015
5/5/2015
STRUCTURAL READY FOR APPROVAL.
RECEIVED
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
4/14/2015
4/15/2015
STRUC BACK ON 4/14/2015, RFC
RECEIVED
PLAN CHECK PICKED UP
MARY FASANO
4/15/2015
4/15/2015,
MIKE MENDOZA PICKED UP PLANS FOR CORRECTIONS
PLAN CHECK SUBMITTAL
PHILIP JUAREZ
3/31/2015
3/31/2015
RECEIVED
SENT TO PLAN CHECK
PHILIP JUAREZ
4/23/2015
4/23/2015
CONSULTANT
Printed: Tuesday, June 16, 2015 10:51:43 AM 1 of 4' SYSTIMS
Permit Details PERMIT NUMBER
�City of La Quinta BRES201, 0112 ,.
TELEPHONE CALL
JIM JOHNSON
4/15/2015
4/15/2015
CALLED MIKE MENDOZA TO INFORM HIM THAT PLANS ARE
READY FOR CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
5/6/2015
5/6/2015
CALLED MIKE TO INFORM HIM PLANS ARE READY TO ISSUE
CONDITIONS
NAME TYPE
NAME
ADDRESSI
CONTACTS
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
MIKE MENDOZA
P.O. BOX 692
DESERT HOT
SPRINGS
CA
92240
CONTRACTOR
DESERT CONTRACTING INC
43-695 NORTH
JACKSON STREET
INDIO
CA
92201
DESIGNER
DESIGN MIND STUDIO
74-79442 ND AVENUE
PALM DESERT
CA
92211
$171.14
$0.00
OWNER
SUE AND ROBERT ANTOLEC
50585 VERANO DR
LA QUINTA
CA
92253
Printed: Tuesday, June 16, 2015 10:51:43 AM 2 of 4 CJ ,
SYSTEMS
DESCRIPTION
ACCOUNT
QTY
AMOUNT
'' PAID, PAID DATE
RECEIPT #
CHECK #
METHOD
,:PAID BY :; _ •
CLTD,,
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$0.00
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$0.00
PC
Total Paid forADDITION: $291.97 $0.00
HOURLY PLAN CHECK -
101-0000-42600
1.5
$105.00
$0.00
YES
HOURLY PLAN CHECK -
101-0000-42600
0.75
$52.50
$0.00
YES
Total Paid forBLDG CITY STAFF - PER HOUR: $157.50 $0.00
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00
BSA:
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
Printed: Tuesday, June 16, 2015 10:51:43 AM 2 of 4 CJ ,
SYSTEMS
Printed: Tuesday, lune 16, 2015 10:51:43 AM 3 of 4
C
DESCRIPTION" :
ACCOUNT
QTY
AMOUNT
z
PAID
PAID DATE
RECEIPT.#
CHECK#•
METHOD.
'PAID
BY
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
Total Paid forELECTRICAL: $48.34 $0.00
FIREPLACE
101-0000-42400
0
$145.03.
$0.00
FIREPLACE PC
101-0000-42600
0
$217.55
$0.00
Total Paid for FIREPLACE: $362.58 $0.00
GAS SYSTEM, 1-4
101-0000-42401
0
$12.09
$0.00
OUTLETS
GAS SYSTEM, 1-4
101-0000-42600
0
$24.17
$0.00
OUTLETS PC
Total Paid forPLUMBING FEES: $36.26 $0.00
REMODEL, EA
101-0000-42400
0
$21.75
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$17.40
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-426000
$134.88
$0.00
PC
Total Paid for REMODEL: $223.34 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$2.60
$0.00
Total Paid forSTRONG MOTION INSTRUMENTATION SM! $2.60 $0.00
DOOR/WINDOW, NEW,
101-0000-42400
0.
$60.91
$0.00
FIRST 1
DOOR/WINDOW, NEW,
101-0000-42600
0
$59.46
$0.00
FIRST 1 PC
Total Paid for WINDOW/SLIDING GLASS
$120.37 $0.00
DOOR/FENESTRATION:
TOTALS: $1,243.96 00
Printed: Tuesday, lune 16, 2015 10:51:43 AM 3 of 4
`t Permit. Details PERMIT NUMBER
City of La Quinta Ov�ll
:., BRES2015-01,12
•
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES -
DATE ; DATE, .
FINAL*" BLD
PROJECTSPARENT
wREVIEW TYPE:
REVIEWER
SENT DATE
DUE DATE,
REVIEWS
RETURNED STATUS y -•
'REMARKS"
-
NOTES "
OWNER
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
DATE
NON-STRUCTURAL
JIM JOHNSON
3/31/2015
4/14/2015
4/7/2015 REVISIONS REQUIRED
JAKE FUSON
PENDING STRUC CORRECTIONS
YOUNG -
3/31/2015
4/14/2015
4/14/2015 REVISIONS REQUIRED
TRANSMITTAL TRANSMITTAL.pdf
STRUCTURAL
DOC
4/7/2015
JIM JOHNSON
50-585 VERANO.docx 50-585 VERANO.docx
SENT TO YOUNG
ENGINEERING
NON-STRUCTURAL
JIM JOHNSON
4/23/2015
5/7/2015
S/6/201S APPROVED
STRUCTURAL APPROVED. READY TO PROCESS.
KATHRYN
4/23/2015.
5/12/2015 •
5/4/2015 READY FOR. APPROVAL
STRUCTURAL -
.
TRANSMITTAL SHEET ATTACHED.
SAMUELS
r
Printed: Tuesday, June 16, 2015 10:51:43 AM' 4 of 4 sysrEMS
Attachment.Type
CREATED*
OWNER
DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
2ND REVIEW BRES2015-0112 - 2ND
.DOC
5/5/2015
JAKE FUSON
STRUCTURAL REVIEW STRUCTURAL
0
TRANSMITTAL TRANSMITTAL.pdf
DOC
4/7/2015
JIM JOHNSON
50-585 VERANO.docx 50-585 VERANO.docx
0
r
Printed: Tuesday, June 16, 2015 10:51:43 AM' 4 of 4 sysrEMS
Bin #
City of La uinta
Building 8i: Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
l Ji
1�7
Permi ol l
5 2n t9�
rte
Project Address: 80- 5 Verano. Drive La Quinta, CA 92253
Owner's Name: M. & Mrs. Antolec
A. P. Number: 777-240-017
Address: 80-585 Verano Drive
Legal Description: Lot No. 72 Tract 30357 Book 777.
City, ST, Zip: La Quinta, CA 92253
Contractor: Mike AS el -Desert Oasis Construction
p
1- 920 366-9092
Telephone• ( )
Address: 79-301 Country Club Drive -Suite 202
Project Description:
City, ST, zip:Bermuda Dunes, CA 92203
Remodel Addition of 31 Sq. Feet and Change of
Telephone: 1-(760) 880-3228
Existing Slider Glass Door & Window For New
State Lic. # :
City Lic. #:
Arch., Engr., Designer: Design' Mind Studio
Address: 74-794 - 42 Nd. Avenue
City., ST, Zip: Palm Desert, CA 92211
:•:r::::iFi:::i'i:::il::::::$:::::::isii:}::j:;ii::i::i::i::i::i::
Telephone: 1- 760 ) 449-4029 .:::::::::.:::::......................
State Lic. #: N/A :;::i::ii::i:<:ii::i:;;;.::.:.;:.<.;::<:>'s::>:::<:<:•
'rt: >:> ` `''i "`''i
Name of Contact Person: Mike Mendoza
Construction Type: VB Occupancy: R]
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: 31.0 # Stories: 01 # Units:
Telephone # of Contact Person: 1-(760275-1816
Estimated Value of Project: $ 20,000.0 .
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Z
Reviewed, ready for corrections
4
Plan Check Deposit
Truss Calcs.
Called Contact Person
1,5
Plan Check Balance.
Tide 24 Calcs.
w
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for eorrectios/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
"d Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
r�
R .
J.
Coachel& Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVELONEAMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE: -
RECEIPT:
CHECK#:INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Mountain;ViewtE"states, Date: May 27, 2015
Owner's Name: Sue and Robert Antolec Phone No. 760-449-4029
Project Address: 50-585 Verano Drive, LaQuinta
Project Description* Remodel Addition
APN: 777-240-017 Tract #: Lot #'s:
Type of Development: Residential . XXL Commercial Industrial
Total Square Feet of Building Area:. 31
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: May 27, 2015 Signature:
-)ft,JLJ E (
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code
17620 65995
Number of Sq.Ft.
31
Amount per Sq.Ft.
$0.00
Amount Collected
$0.00
Project Agreement_ Existing Not Subject to Fee
Approval Prior to 1/1/87 Requirement
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Note:
Pursuant to AB 181 any. room additions. or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are exempt from developer fees.
Certificate issued by: Laurie Howard, Secretary Signature: 0aw
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in: part prior to issuance of a Certificate of Occupancy.. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
M V:c/mydocs/devfees/certificate of compliance form updated 3-2007 11/2010
Mountain View Country Club Homeowners Association
c/o Albert Management, Inc.
PO Box 12920, Palm Desert, CA 92255-2920
760.346.9000
760.346.9997 Fax
May 4, 2015
Robert Antolec and Suzanne Wilde-Antolec
4248 Westbrook Ct
Oneida, WI 54155
Re: Property located at: 50585 Verano Drive, La Quinta, CA 92253
Account Number: 101401930
eSlid!gArc tectara Approvalfor RpcnGlasoors�— —
Dear Homeowner(s):
Please consider this written confirmation that the Architectural Committee has approved your application for replacing
two patio doors with one full door by removing the bump out area on right side and adding thirty one square feet to the
rear of your home. Enclosed is a copy of your approval and your original application for your file.
The CC&Rs provide the Architectural Committee with the duty and responsibility to review all applications requesting
additions, alterations, improvements, or modifications to the exterior of his/her residence, residential lot, and/or the
common area and to ensure that the architectural applications comply with the Architectural Application Guidelines and
Procedures and comply with the Association's Governing Documents and are consistent with the o rev all conformity and
harmony of the original design and the aesthetic beauty our community.
We thank you for your cooperation in following the architectural procedures. Please contact our office upon completion
of this project so that the final completion may be signed off by the Architectural Committee and if applicable, any
refundable deposit returned.
Should you have any questions please reach out to your point of contact, Cardinal Ambrose, CCAM, CMCA, AMS at
760.346.9000 or by email at cardinal.ambrose@albertmet.com.
Sincerely,
On behalf of the Architectural Committee
Mountain View Country Club Homeowners Association
WtWAO�"VWVAMN�-UAW92
Association Manager
Cardinal Ambrose, CCAM, CMCA, AMS
cc: Architectural Committee
: . _
MOUNTAIN VIEW ARCHITECURAL GUIDELINES — EXHIBIT D
CONSTRUCTION REGULATIONS
Any damage done to common areas/lots.as a result of this construction must be repaired prior to completion. j
The refundable deposit will be held until the Association receives a Notice of Completion form and the
Association inspects and approves the project. The Association may use funds from the refundable deposit to
correct any deficiencies.
I . No dirt, debris or other related construction material is to be dumped on any part of the Mountain View Country
Club property including the undeveloped land. All excess material is to be disposed of off-site.
2. No material is to be delivered and placed in the street. Do not stockpile material on adjacent property, including
the golf course. Contractors will be required to place all pallets, cement and other materials in Owner's driveway,
yard or garage. Any material stockpiled in the driveway shall be left so that it will not be an annoyance, visual
distraction or hazard to surrounding Owners. Do not block any mailbox access.
3. On a daily basis all trash and debris is to be picked up and the street cleaned. Owner and contractors shall check
with the Association to determine the regular day the streets are cleaned. When a hazard has been created, such
as an open trench, hole, exposed wiring, etc., the owner indemnifies the Association for any and all claims arising
from said hazard. No existing barriers are to be removed to gain access to the property or any other areas.
4. The existing irrigation and electrical facilities may be affected by your work. When damage is done to such
systems, neighboring lighting, irrigation and/or landscaping may not operate properly, resulting in expensive
repairs. Contact the Association when any repairs are required to such facilities.
5. No access via the golf course is permitted without obtaining written permission from the golf course owner and
providing that to the Architectural Committee before any work begins. No existing barriers are to be removed to
gain access to the property or any other areas without written approval from the Architectural Committee.
6. Owner must verify all adjacent property lines before starting any work.
7. During the course of work, all vehicles shall be parked on one side of the street so congestion will not be created.
There will. be no parking in or blocking of the driveways of surrounding Owners.
8. Should any portion of the job not be in compliance with these Architectural Guidelines, the contractor shall be
responsible for removing the non-compliant portion at his own expense.
9. All damages or non-compliance with these construction, regulations must be repaired prior to the completion of
the project. If not corrected, the Developer/Association will complete the work and assess the Owner.
10. Drainage systems must be confined to the Owner's property and designed'to adequately carry the water away
from the structure to the street.
11. Failure to comply with the above regulations may result in denial of the Contractor's entry into Mountain View
Country Club.
12. Construction to take place only during Association approved hours and days as set forth in the Architectural
Guidelines. ''�
Owner• Q �Q yt CC t. df �L b AddressJO Q i Date:
Print Namc and Sign nn A
Contractor:A CA Lie. #: q 0 T 1 � `b Phone: �D� a��1 4�
31
CITY�~U���x ��K�'K°�� ��U Uk���-�� ��KV�� �� '
. -`' -'' ----^^~^^^ ~'^^-- � ^4
--_ ''__'.-_ BUILDE13
This form shall be posted on'thd iob'v�ith the Buildin� Inspection Card at all times in a conspicuous
Only persons appearing on this list urthoir.nrnp|oyeey are outhonzedtovv�ru
onthis job. Anyohangaatothis Ustrnumt�beappruvadbythe Bui|dingDivision phort000nnnnanoannentofvvork' Failure touunop|yvviHresu�innstoppage ofvviorkand/or the voidance.
` '
ot building permit. For each applicabletrade, all intormation requestea I)elow must be completed -by applicant. "Un File" -is not an acceptawe response-.
rI-mmm�w.
usiness
Company.Name
�Cl6ssification
License �Nu mber
Exp. Date
Carrier Name.
Policy Number
p. Date
lumber
License Number
Exp. Date.
Aber
E.
rI-mmm�w.
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. Antolec
50585 Verano Drive @ Mountain View C.C.
La Quinta, Ca 92253
Project Designer:
Mike Mendoza
P. O. BOX 692
Desert Hot Springs, Ca 92240
1-(760).275-1816
Report Prepared by:
Santiago Lopez-Ocampo
Santiago Lopez-Ocampoas- i ®
P.O. Box 1018
La Quinta, Ca 92247m oF�'�t� QM�NS
760.485.8927 c �y o
c0MM��
Job Number:
LQ032915Corr042115
Date:
CITY OF LA QUANTAO 5
BUILDING & SAFETY DEPT.
AP R V
The EnergyPro computer pr gram his n ftp lations smmarized in this compliance report. This program has approval and is
authorized by the California Energy Commission r �Vffh�(e Residential and Nonresidential 2013 Building Energy Efficiency Standards.
LATE L is ra eloped by EnergySo , LLC — www.energysoft.com.
EnergyPro 6.5 by EnergySoft User I ID: LQ032915Conr0421 P
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis
Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CFI R -PRF -01
Page 1 of 9
GENERAL INFORMATION
01
Project Name Mr. & Mrs. Antolec
02 X hbb m incorporates features that require field testing and/or verification by a certified HERS rater, under the supervision of a CEC-approved HERS provider.
02
Calculation Description Title 24 Analysis
z go y I 'I ice- 1 1 --J� 1 t% tJ' E
03
Project Location 50585 Verano Drive Q Mountain View C.C.
'< —1 ENERGY USE SUMMARY
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT) 3006
15
Number of Zones 2
16
Slab Area (FT2) 3006
17
Number of Stories 1
18
Addition Cond. Floor Area 31
19
Natural Gas Available Yes
20
Addition Slab Area (FT) 31
21
Glazing Percentage (%) 21.0%
C3
CO PLrm NCE RESULTS
01 1.1 Bu in o plies with Computer Performance"
02 X hbb m incorporates features that require field testing and/or verification by a certified HERS rater, under the supervision of a CEC-approved HERS provider.
03 it i g incorporates one or;rnore Special Features shown below
KV
z go y I 'I ice- 1 1 --J� 1 t% tJ' E
L-0 �L-
'< —1 ENERGY USE SUMMARY
C 05 06
07
08
e Standard Proposed
2 yr) Design Design
Compliance
Margin
Percent
Improvement
e ting 0.29 0.70
-0.41
-141.4%
Shia ling 207.28 206.55
0.73
0.4%
O Vent' ation 0.00 0.00
0.00
0.0%
Water Heating 8.87 8.87
0.00
0.0%
Photovoltaic Offset ---- 0.00
0.00
----
Compliance Energy Total 216.44 216.12
0.32
0.1%
Registration Number: 215-AO08232OB•000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec
Calculation Description: Title 24 Analysis
Calculation Datelrime: 20:49, Tue, Apr 21, 2015
Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 9
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
--None —
Cooling System Verifications:
• -- None —
HVAC Distribution System Verifications:
• -- None —
Domestic Hot Water System Verifications:
. __ hinno —
ENER ESIGN RATIN
0 f71
This is 1h sum of Mo nnubtf n rgy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV e e gy consoq fair i g nd components not regulated by Title 24, Part 6-(s'uch' as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -sit r newable�ll t� 1 3� { 1 . j ` � •• i ��' i ) \� � � [ �' r/
O,
l Reference Energy Use�� L Energy Design Rating Margin Percent Improvement
Total -Eder (JaDV y )'
J258.107 P e,— 257.78 0.32 0.1%
' in u VJ
s cal e�p n,,.6,, a d Miscellaneous Energy Use (AMEU)
roe
B I DING - II4F6R ATION
0 f71
02
03
04
05
06
07
'ect Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mr. & Mrs. Anto`lec
3006
1
3
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing
Conditioned
Existingl
2975
11
DHW Sys 1
Addition
Conditioned
Existingl
31
11
DHW Sys 1
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis Input File Name: Mr. & Mrs. Antolec - Corr 042115.xmi
CF1 R -PRF -01
Page 3 of 9
OPAQUE SURFACES
�7
02
03
04
05
06
07
08
09
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
RIME
Existing
R-19 Wall
90
315
1001
43.3
90
Existing
No
Re/N
Existing
R-19 Wall
0
225
31.1
15
90
Existing
No
Re/NW
Existing
R-19 Wall
315
Back
528
301.5
90
Existing
No
Re/W
Existing
R-19 Wall
270
135
97.2
39
90
Existing
No
Ri/SW
Existing
R-19 Wall
225
Left
682.2
146.4
90
Existing
No
Fr/SE,
Existing
R-19 Wall
135
Front
624.2
51.3
90
Existing
No
Fr/S, 10.91'x 11'
Existing
R-19 Wall
180
45
119.8
62.5
90
Existing
No
Roof
Existing.
R-38 Roof Attic w/Radiant
549
Existing
No
Roof 2
Existing
R-38 Roof Attic w/Radiant
893
Existing
No
0 Roof 3
Existing
R-38 Roof Attic w/Radiant
663
Existing
No
—1 Roof 4
` Existing
-R-38 Roof Attic w/Radiant
�.
870
Existing
No
Re/NW
Addition . '. -
/ R-21 Wall`
315
IBack
85.9
90
New
N/A
Ri/S 0
Addition
-21 Wall
l F0�N 1
225
22.5
90
New
N/A
Rom
Addition ��'
R=38'Roof Attic w/Radiantw — _
1I
31' `"
New
N/A
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
�7
02
03
04
05
06
07
08
09
10
C7 M JO
41":�
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
A F_xi tj
Attic Roof Existing
Ventilated
4
0.1
0.85
Yes
No
En9t1
No
Attic Addifi-A
Attic RoofAddition
Ventilated
0
0.1
0.85
Yes
No
New
No
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis
Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CF1 R -PRF -01
Page 4 of 9
WINDOWS
01
02
03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth) Width(ft)
Multiplie,
Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
[E] 2434 GB
Ri/NE (- specify --90)
----
---- 1
7.8
0.51
0.66
Insect Screen (default)
Existing
No
[E] 2040 GB
RUNE ( specify --90)
----
---- 1
8.0
0.51
0.66
Insect Screen (default)
Existing
No
[E] 2040 GB 2
RIME (- specify --90)
----
---- 1
8.0
0.51
0.66
Insect Screen (default)
Existing
No
[E] 1440 GB
RIME ( specify --90)
----
---- 1
5.3
0.51
0.66
Insect Screen (default)
Existing
No
[E] 1440 GB 2
Ri/NE ( specify --90)
----
---- 1
5.3
0.51
0.66
Insect Screen (default)
Existing
No
[E] 1440 GB 3
RIME ( specify --90)
----
1
5.3
0.51
0.66
Insect Screen (default)
Existing
No
[E] 1414 GB
RIME ( specify --90)
----
---- 1
1.8
0.51
0.66
Insect Screen (default)
Existing
No
[E] 1414 GB 2
RIME (- specify --90)
----
---- 1
1.8
0.51
0.66
Insect Screen (default)
Existing
No
[E] 2060
Re/N (- specify --0)
----
---- 1
12.0
0.55
0.67
Insect Screen (default)
Existing
No
p [E]
Re/N ( specify --0)
----
---- 1
3.0
0.55
0.67
Insect Screen (default)
Existing
No
-� [E]508000
rn_
Re/NW (Back -315)
----
---- 1
40.0
-
0.55
0.67
Insect Screen (default)
Existing
No
E •01 v
Re/NW (Back -315)
� � 1�
t; 7.5
10.55,..-,
, 0.67y
Insect Screen (default)
Existing
No
� 667 ^�
ReMW,(BaW315)
` y t�
_ `�� 1 [#
3ti.0
(0.55
A:67
Insect Screen (default)
Existing
No
1 O
Re/NW (Back -3215)
`' �
`' " 1
tr``9A(/
`0.55 _
' 0.67'
Insect Screen (default)
Existing
No
Z[
Re/NW (Back -315)
I--1 C---* C
] ---- 1
X24.0 f
10:55 C
0.67
Insect Screen (default)
Existing
No
�[ ^ OZ>�
Re/NW (Back -315)
----
---- 1
15.0
0.55
0.67
Insect Screen (default)
Existing
No
7 SQD
ReMW (Back -31 5)j
17.0
10.0
170.0
110.56
10.32
Insect Screen (default)
New
N/A
Re/W (- specify --270)
----
---- 1
24.0
0.55
0.67
Insect Screen (default)
Existing
No
0 2�-
Re/W (- specify --270)
----
---- 1
12.0
0.55
0.67
Insect Screen (default)
Existing
No
[
Re/W ( specify --270)
----
---- 1
3.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 30601>:Ri/SW
(Left -225)
----
---- 1
18.0
0.55
0.67
Insect Screen (default)
Existing
No
3D 6
Ri/SW (Left -225)
----
---- 1
4.5
0.55
0.67
Insect Screen (default)
Existing
No
[E] 3060 2
Ri/SW (Left -225)
----
---- 1
18.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 3016 2
Ri/SW (Left -225)
----
---- 1
4.5
0.55
0.67
Insect Screen (default)
Existing
No
[E] 2014 GB
Ri/SW (Left -225)
----
---- 1
2.7
0.51
0.66
Insect Screen (default)
Existing
No
[E] 2014 GB 2
Ri/SW (Left -225)
----
---- 1
2.7
0.51
0.66
Insect Screen (default)
Existing
No
[E] 4016
Ri/SW (Left -225)
----
---- 1
6.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 1060
Ri/SW (Left -225)
----
1
6.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4060 2
Ri/SW (Left -225)
1
24.0
0.55
0.67
Insect Screen (default)
Existing
No
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Datefrime: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis Input File Name: Mr. & Mrs. Antolec - Corr 042115.xmi
CF1 R -PRF -01
Page 5 of 9
[E] 1060 2
Ri/SW (Left -225) ----
---- 1
6.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4060
Ri/SW (Left -225) ----
---- 1
24.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 2030
Ri/SW (Left -225) ----
---- 1
6.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4060 3
Ri/SW (Left -225) ----
---- 1
24.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4036 GB
Fr/SE, (Front -135) ----
1
14.0
1 0.51
0.66
Insect Screen (default)
Existing
No
[E] 4020
Fr/SE, (Front -135) ----
---- 1
8.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 2040
Fr/SE, (Front -135) ----
---- 1
8.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4060 4
Fr/S, 10.91' x 11'(- specify --180) ----
---- 1
24.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 4016 2
Fr/S, 10.91'x 11'(- specify --180) ----
---- 1
6.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 3016 3
Fr/S, 10.91'x 11'(- specify --180) ----
1
4.5
0.55
0.67
Insect Screen (default)
Existing
No
[E] 3060 3
Ri/SW 2 ( specify --0) ----
1
18.0
0.55
0.67
Insect Screen (default)
Existing
No
[E] 3016 4
Ri/SW 2 (- specify --0) ----
1
4.5
0.55
0.67
Insect Screen (default)
Existing
No
DOORS
. .,
... ` ..� ..
01 02
03
04 05 06
D Name Side of.Buildingn
r---, r cArea
rl U -factor Status Verified Existing Condition
F1m 288 - (( Fr/SE,� I !
1 �� 21.3��
f 0 50 fr �` Existing No
19 AEUE-17 I <N\1 FNS ;10:911x.11T
[ q; 328.0_--1
], 0.50 Existing No
I I - l 1=; _ I "I 1 M n r-- is r" r1 e"% rt 11 i t r-4 r- n
O E HANG V
. .,
... ` ..� ..
rzn X 110
02 03 04
05 06
07 08 09 10
11 12 13 14
D
Overhang
Left Fin
Right Fin
C M /1
tfVFlap
C� o fV
Depth
Dist Up
Left
Extent
Right
Extent
Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
D--
13
0.1
1 1
1 1
1 0
1 0
1 0
1 0
1 0
1 0
0
0
0
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CF1 R -PRF -01
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Z T Qo
CU W �+
N rY�
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
0.1
None
0
No
Existing
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
Existing
1030
0.1
2x4 Top Chord of Roof Truss Q 24
1
No
Roof Deck: Wood Siding/sheathing/decking
Attic Roof Existing
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
No
New
No
• Inside Finish: Gypsum Board
• Cavity / Frame: R-19 / 2r6
• Exterior Finish: Wood
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.069
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic w/Radiant
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss Q 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
-
Inside Finish: Gypsum Board
• Cavity/ Frame: R-21 /2x6
D
j=Wall
Exterior Walls
�-�
Wood Framed Wall
(� r t—
2x6,,@.24 in: O.C.
R 21
Exterior Finish: Wood
Siding/sheathing/decking
r
l
/,0.063
S FLOORS O
1 0\02
1 1 =�»
x-03
%04 T-%
V 105L0 C-- F-%
06
07
08
09
Z T Qo
CU W �+
N rY�
Zone
Area (ftZ)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
C cod
Existing
1945
0.1
None
0
No
Existing
No
—I d
Existing
1030
0.1
None
1
No
Existing
No
I
ISMOr
Addition
31
0.1
None
0
No
New
No
B I DINGENVELOPE--DgilVERIFICATION
02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH Q 50 Pa
Not Required Not Required Not Required ---
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CF1 R -PRF -01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.575 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04 05
06
07
;(OD Name
Pipe Insulation
Parallel Piping
Compact Distribution Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
R1 DHW Sys 1
n/al-, - f� ``
/ n/a' IF— J iF*",
'l ""J f'((n/a � � 1n/a
n/a
n/a
1 1 n A = d 1 / IC% ii r -I II 1L Ir^-- I-,. Ir -1-N II Ir 11 1!
SPA CONDl1fb `� c �,ij (`"' Il 61 I.l ld (! Q
01 0
"*-403 >< -1 I –
R S 04.E R C
) V051 L
) PIS R
07
08
09
Z Qo
Heating System
Cooling System
_CnI to
Distribution
Fan
Floor Area
Verified Existing
Name X D S e Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Existingo t�i ating and
System
Heating
Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan
1
3006
Existing
No
_-I n .
H C -HEA GS
01 02 03
ame Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CF1 R -PRF -01
Page 8 of 9
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
8.488
9.7
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located entirely in
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located entirely in
Existing (not
Conditioned
Conditioned
System 1
conditioned space
specified)
8'0
Zone
Zone
None
Existing
No
N/A
IAO (Indoor Air Ouality) FANS
02 03 04 05
Name IAO CFM IAC Fan Type IAO Recovery Effectiveness(%) HERS Verification
SFaM1 V J(0 1 f! f 1� J U) 'Default. 11 + � 0 Not Required
U LL=[I '� U p U U Udo
HERS PROVIDER
Registration Number: 215-AO08232OB-000000000-0000 Registration Datefl-ime: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Mr. & Mrs. Antolec Calculation Date/Time: 20:49, Tue, Apr 21, 2015
Calculation Description: Title 24 Analysis Input File Name: Mr. & Mrs. Antolec - Corr 042115.xml
CF1 R -PRF -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Santiago Lopez-Ocampo
Company:
Signature Date:
Santiago Lopez-Ocampo
Address:
CEA/HERS Certification Identification (If applicable):
P.O. Box 1018
NA
City/State/Zip:
Phone:
La Quinta, CA 92247
760 485 8927
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
3. building design feat es or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
I
sheets, calculi s and specifications submitted to -the enforcement agency.for approv al,with thisbuilding permit application.
Respo s ble Desi aTi Ir Respon}sible D`es�igner Sign{atufr{e:
L1k71,A\ i C'
Sant o Lop�Li- po C� i`W' i i c-� I� ! 11'I
Comp
n: O �1 -
H E R S P
!� !'
Date Signed: V "l D E R
San
o LopK2- Lipo
Addre
s: CO --� ®D
License:
P.O
qox 101 -nm
NA
e
City/S!
/Zip: C
Z , -„IM r l
Phone:
inta, C b7604858927
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-AO08232OB-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-04-2120:52:21
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Mr. & Mrs. Antolec
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
4/21/2015
Project Address
50585 Verano Drive @ Mountain View C.
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,006
Addition
31
# of Units
1
INSULATION
Construction Type
Area
Cavity Special Features Status
Slab Unheated Slab -on -Grade
- no insulation 2,975 Perim = 0'
Existing
Wall Wood Framed
R 19 2,668
Existing
Door Opaque Door
- no insulation 49
Existing
Roof Wood Framed Attic
R38 2,975
Existing
Slab Unheated Slab -on -Grade
- no insulation 31 Perim = 0'
New
Wall Wood Framed
R 21 99
New
Roof Wood Framed Attic
R 38 31
New
FENESTRATION
Orientation Area
TTotal Area: 632 Glazing Percentage: 21.0%1New/Altered
U -Fac SHGC Overhang Sidefins
Average U -Factor: 0.56
Exterior Shades Status
Right (E) 43.3
0.510
0.66 none none
Bug Screen Existing
Rear (N) 37.5
0.550
0.67 none none
Bug Screen Existing
Rear (NVtg 131.5
0.550
0.67 none none
Bug Screen Existing
Rear (NVtoq 170.0
0.560
0.32 13.0 none
Bug Screen New
Left (Vtoq 39.0
0.550
0.67 none none
Bug Screen Existing
Left (SVtoq 141.0
0.550
0.67 none none
Bug Screen Existing
Left (SlAq 5.4
0.510
0.66 none none
Bug Screen Existing
Front (SE) 14.0
0.510
0.66 none none
Bug Screen Existing
Front (SE) 16.0
0.550
0.67 none none
Bug Screen Existing
Front (S) 34.5
0.550
0.67 none none
Bug Screen Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
2 Central Furnace
78% AFUE
Split Air Conditioner 9.7 SEER
Setback Existing
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
Existing Ducted
Ducted Conditioned
8.0 Existing
UI NTA
Status
WATER HEATING
Qty. Type Gallons IV
BUILDING & SAFETY DEPT,
in. Eff
DATE B
EnergyPro 6.5 by EnemySoft User Number. 5732
Run Code: 2015-04-21720:54:01
/D: L 032915Corr0421 V Pae 12 of 17
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a).
§110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§110.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §I 10.8(1) when the
installation of a cool roof is specified on the CF 1 R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§150.0(g)l:
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
antes without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c).
§150.0(j)lA:
Storage gas water heaters with an energy facto equl�t lEs t e f era minimums s shall be externally wrapped
with insulation havingan installed thermal resi t 2 r t r.
§150.OQ)1B:
Unfired hot water tanks, such as storage tanks d 1y3,�q� �]� w bei-Walings stems, have R-12 external
insulation or R-16 internal insulation where th int�rnalsul'dtiolfl� s i atFo�t�e ex rior of the tank.
For domestic hot water system piping, whethe4 buried o i . rs o and cok water pipes from the storage
tank, all piping with a nominal diameter of 3/4inch or �4 Q� domes c hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from th heating source t 9e+ tanks, iping buried below grade, and
all hot water pipes from the heating source to Itchen fixtures must be insulated according to the equirements of TABLE 120.3-
A.
§150.0(j)2B:
All domestic hot water pipes that are buried b e mus a irr�a-waterpree€+ on -crushable casing or sleeve
that allows for installation, removal, and re lacement of the enclosed i e an msu a ion.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than V< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m) 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling system s a ta�uliane I delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handle f t]<4.�1eT er ton of nominal cooling
capacity, and operating at an air -handling unit fan a ica < 5 CF c Ave ification and diagnostic
testing, in accordance with Reference Residential A e U
§ 150.0(0):
All dwelling units shall meet the requirements of A HRAE S r do a ion or continuous operation of
central forced air system air handlers used in centra fan inte a v nti s �Ormissibl
methods of providing the
Whole BuildingVentilation. Q
§150.0(o)IA:
Whole Building Ventilation airflow shall be confi ed through field verificat1on an i is test' g, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures: ----__ Y
Any pool or spa heating system shall be certified to have: a thermal efficiency t a comp Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§I 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§I 10.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§ 150.0(k)I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§I50.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§I50.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §I50.0(k)2.
§150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; h t with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance wi h r6A�n a d itl�¢rTk tween the luminaire housing
have J�c`�s
§150.0(k)8:
and ceiling, and shall all air leak paths be en ti ne u ti s a d mith a gasket or caulk; and
allow ballast maintenance and replacement with ut r(S CEDING 616ARETeVrREPT
For recessed compact fluorescent luminaries witl ballasts c�:Umpliancwith § 150.0(k), the ballasts
shall be certified to the Ener Commission to 'L m 1 wi au110.9.
For single-family residential buildings, outdoor I ghting 0fJMe al buil ing or other buildings on the
same lot shall be high efficacy, or maybe low a rcacy if it meets all of the following requirements
i. Controlled by a manual ON and OFF switch th t does not override to ON the automatic actions Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an o 1�fAr bypass switch ��t disahlec the mnrinn ensor, or controlled by a
motion sensor having a temporary override switc nction and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9, 130.0, §130.2, §130.4, 140.7 and 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.10(b) through § 110.10 e .
§I 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §I10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§I 10.10(d):
A copy of the construction documents or a com ara ng amf on tom §I10.10(b) through §110.10(c)
shall be provided to the occupant.
§110.10(e)l:
The main electrical service panel shall hav4a&iAU bu ratm
§ 110.10(e)2:
The main electrical service panel shall hav a reg ion of a ouble pole circuit breaker for a
future solar electric installation. The resery d space d
sly�ll� e�te (load) nd from the input feeder location or
location, "F
main circuit and ermanently mar ed as r tur
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs. Antolec
Date
4/21/2015
System Name
Existing
Floor Area
3,006
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
2,621
o
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 0
54,404
3,824 841
32,906
Total Output Btuh 0
0
Output Btuh/s ft 0.0
787
391
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 2
0
3,824
0
Total Output Tons 0.0
787
391
Total Output Btuh/s ft 0.0
Total Output s ft/Ton 18,036,000.0
55,979
33,689
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow (cfm)
0
Default FAU/AC 1992 - 2005
2 0
0
Airflow cfm/s ft 0.00
Airflow cfm/Ton) 0.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
2 0
Aug 3 PM
0
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
68 OF
68 OF 105 OF
Heating Coil
L
105 OF
ROOM
68 OF
I
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
75/62°F 55/54°F
T
i e / i
BUILDING & SAFETY DEPT. 55/54°F
APPREC OOM
FOR CONS OCTI i
175/62°F
I I
Outside Air
0cfm Cooling Coil
75/62°F
EnergyPro 6.5 by Energ Soft
User Number: 5732 RunCode: 2015-04-21 T20:54:01 /D: LQ032915Corr04211; Page 17 of 17