Loading...
0006-041 (RPL)LICWED-CONTRACTOR DECLARATION _I. hereby affirm under penalty of perjury that I am licensed under provisions of -Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class —Exp: Date 574127 A ,, 08/31/V "" d' Date '`f" "Signature of Contractor,42" OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Cartier STATE FUME) Policy No. 046-00-00OW54 34 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California and, agree that if I should become sub'ect to the workers' compensatiomprovisior'Vof Section 3700 of the Labor Cdde, I shall forthwith comply with those•provi6ons. bate: fj,,,-• LL') Applicant --,`i ce-1� ,c: -` Warning: Failure to secure Workers' Co pensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and,_ State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the bove-mentioned property for inspection purposes. ignature (Owner/Agent) Date % _0 BUILDING PERMIT PERMITk DATE VALUATION LOT' TRACT $22,0W.00 JOB SITE APN ADDRESS 55-138 TMGaWOOD _ OWNER _ CONTRACTOR / DESIGNER / ENGINEER CF.MURY CROV&1.,;%. COMMUl4i'x'� .' STEW DOi3S011T CCtiRiSTRUCgio1+1 INC. 1$3:5 80. "D" MRM. i, 0200 73011 CUZ7M,RY L' UB 722,, W'!'EF4 :IAN BLRWARDINO CA 92408 P.f'LM;-DE,WW1' CA 92260 (760)346-4012 CBLIf 1044 USE OF PERMIT POOL.. AM/OR SPA. POOL $SPA ONLY- ALA RMMARRIERS SHALL 8E I;d PLACE AT 1: RE-PIAOTER INSPECTION, THIS PERMIT DOW NOT INCLUDE BLOCK WALL FOR EQUIPMENT ENCLOSURE VALUATION 22,000,00 LS X5TV"ll 2 C:OI+T 011' COINS'71t€ anon FIERMT YU St RY Plated CHECK FEE 101.000-439-318 5146.25 CONSTRUCTION FEE 101-0400-418-000 $225.00 MECHANICAL FEE POOL 101.000-421-000 524.00 KLf rPJCAL PER -.POOL 101-000-420-000 $45.00 PLtlMBINO RR •- POOL 101-600419.000 $27,00 SUB-1'OT.AL COA grRUC2ION AND PUS CRUCIC RECEIPT I DATE TOTAL P=Mff"PTE8 DWE i?OW E�i;aT��=i7 DATE FINALED I INSPECTOR $46;7.25 $0.00 $46725 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans 0. K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel X,_ Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric - Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test 7. Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation 14 4*&A Gas Piping 2t� Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: ILI JA -rCe- bill -04- I ti 'i) Fl j1 New an CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED u FOR CONSTR c i0 Ut,TE 116 FP ,FY'l-s7rplq& wrrza�e Wel 11 �-, I. k D r/k 1vt t4t4e qS7,7,A' HEAT N-GLO L fcStylc Products Models: PCFL-HNG PCF-HNG Patio Campfire Decorative Gas Log Set Owner's Manual Installation and Operation GAS -FIRED C &US LISTED CAUTION {°` 1 DO NOT DISCARD •rHIS MANUAL �t Important operating and Read, understand and follow ^ Leave this manual with ` maintenance instructions these instructions for safe party responsible for included. installation and operation. use and operation. A WARNING If the information in these instruc- tions is not followed exactly, a fire may result causing property '• damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas: - Do not try -to light any appliance. - Do not touch any electrical switch. Do not use any phone in your building. - Irnmediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. - If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. A WAR14ING 4 4G /�, 0 HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT. a�' Glass and other surfaces are hot during a=• s.. ? operation and cool down. , I MUM Keep children away. • CAREFULLY SUPERVISE children in same room as appliance. • Alert children and adults to hazards of high temperatures. • Keep clothing, furniture, draperies and other combustibles away. Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies ;l suggests NFI certified or factory -trained i •Y•reru��. prafaSSlpfl als, or techoician5 sllpeFVISed w odff a gy by an NA certified professional. • Heat-N-Glo Lifertyles • Patio Campfire • 4004-001 Rev 1) • 07/05 Listing and Code Approvals ����aau:m5�:�ss�x r rai u� r� mar A. Appliance Certification MODELS: PCF-HNG, PCFL-HNG LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Decorative Gas Log Set STANDARD: IAS US requirements For Outdoor Gas Fireplaces, Draft 4-96 and ANSI Z21.58-1995/ CGA 1.6 M96 The Patio Campfire has been tested in accordance with IAS US requirements for Outdoor Gas Fireplaces, Draft 4-96 and ANSI Z211.58•.19951CGA 1.6-M96 for Cana da and has been listed by Underwriters Laboratory (UL) for installation and operation as described in these installation and operating instructions. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or CAN/C'GA••BI49.1, National Gas Instal- lation Code or CAN/CGA-13149.2, Propane Installation Code. B. BTU Specifications Max Input Model BTUH Orifice Size PCF-HNG 75,000 #27/.144 PCFL-HNG 60,000 1 #44/.086 C. High Altitude Installations U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifice size, check with the local gas utility. If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities. Heat-N-Glo Lifestyles • Patio Campfire - 4004-001 Rev D • 07105 Redd this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Heat-N-GIo Lifestyles decorative gas log set. Th' Patio Campfire you have selected is designed to provide the utmost in safety. rwljability, and efficiency. As the owner of a patio Campfire, you'll want to read and carefully follow all of the instructions contained in this owner's manual_ Pay special attentjoh to all cautions and warnings. This owner's manual should be retained for future reference. We Suggest :you keep it with your other important documents and product manuals. Homeowner Reference Information Model Name: Serial Number: — —•- Dealership purchased from: Notes: ---- The information contained in this owner's manual, unless noted otherwise, applies to all models and gas control systems. Your new Patio Campfire will give. you years of durable use and trouble -free enjoyment. Welcome to the Heat-N-GIo Lifestyles fa[Ili ly of appliance products! We recommend that you record the following pertinent information about your appliance. Date purchased/installed: Location on appliance: Dealer phorl Listing Label Information/Location The model information regarding your specific appliance can be found on the rating plate located in the control area of the appliance. Model Gas Type usrED C U I a 221JM I Modeal MC.rlele PCF-HNG IAS U S, F1-30 OIJ FDOOR GAS FiRE:PL.AC_ For Canada Z21.5i1,10951G:P. 1-ii�•PR9.5 Type of G.,v IJatural Gas q�'^^^'•_! Sort, De C.I.W.' Natnl'el Orifice Size Serial # rth Technologi i02. Kensington Blvd 3keviile, MN 55044, MF(: DP.Tf- Serval/Serie OP DATE DE F B. AI1iNide 0-2( 2000-45 )0 fL (in Canada) Inpul' 75,000 QII W (,20 kW) 67.500 BTUH (19 0 k1N) Urilica Size: ir27 DMH U8 DMS Min Gas supply for Input Ad; r Alimentation en gaz min- pour reglace de la puissance: 7.0 in. w.c (17 kPa) Max. Gas Supaly / Allimehl;Yinn en gsa max: 14.0 In. w.c. (3.5 kPa) Manifold PmSALIre, r Puissance de pr"sion d'admission de: 3.5 in w.c. (.87 kPa) WARNING: Must Not Be Usod For Cooking- AVERWSS'=T.MENT: Ne nas utilisor pour la cuisson- WARNING: For Outdoor Use Orly_ AVERTISSEMENT: Pour utilisaliun 6 I'extArieur seulernent- MINIMuiA CLEARANCES: Eollonl: 0 inch Too: 8 Ft, (2.41-n) DEGAGEMEt•rr MINIMAL.: Des::ous: 0mm Superieure: 2.4m Minimum cicalrance `ron sides and back of unit to adjacent combustible construction below top of unit, 24 inches from sides and 24 inches frorn back. Minimum horizontsd clearance frr.,n, stirs and bacl, of unit to ad)acen( vertical combustible construction extending above top of unit, 24 Incl-es from sides and 24 incites from back. DAgagemenl m:nlmol i resp>ch:r e t;e Iris c6tes et I'nrriere de I'appareil (d Lino consV! dial combustible )djacente SIWAe au-des>ous de la pa(lte sup6deure de I'appareil, soil 24 pourer des cO&S et 24 po ices do I'arrieie. D(.gaye(Tienl horizontal minimal ae wspeOW entre !es wl(:s et I'arri6re de I'appareil et Line construction combustible verticals adjacento der:issani la pallie slipE,rieure de I'appareil, soil 24 pouce-s des c6tPs of 2.1 i)OLICe,S dH I'arriere This aphance must be installed i i accordance with local codes, if any. If none, follow ANSI Z223 1 or CAN;CGA,-B149, installation codes cet rtr.',rt111 W1Li ifre fne:e116 Cn,Tforn1�rnent 0 ax axiuencrsdes•c[adas 1pcaulr. S k n'eicLste usunt pde Vic at rciftulter P; neirme CANrCGA p14Wd T(1- ----;i -+1- R. '• q*A: 1. 122 42y. •SA24.1 z, 4..570 ?!'1 . 73J 117'?�S: ra9 A 875 4A4 g.9Gn Iti2:5:�11C.fill9. 5:17fi.ifi4. !.151.077; (o ., .r. 1 I]p o[" •:d :rmn (A the ir'lla•wmy p,31ea(,, ;IJ ili'd `Slaiic) 4,117313;-0,i.,' . 5 219 :f:,3 :`• "!:'O.:ISn; ii 429 •:95: i.•1 ii2 ; e1; 5 54Z,407: 5,61:+,,ir.i (Auor4al 5431'90l 5116383: (Crnadai 1 Et.s_JFfi: 1 29'7.7".fi 2 19 1fi4;R.dc.kal 97 U.`.': tNxa• Zu .;,::d) 2W.?C•5 or nlnrr IJ �. r..a ir'w'gn Rgncln re••-:ronyl Heal-N-GIo Lifestyles • Patio Campfire: • 4004-001 Rev D • 07/05 1 2 3 4 Table of Contents Listing and Code Approvals 4 A. Appliance Certification ..................... . ...4 B. BTU Specifications . . .........................4 C. High Altitude Installations ......... . ............ 4 Getting Started 5 A. Design and Installation Considerations ........ ....5 B. Tools and Supplies Needed ..................... 5 C. Inspect the Appliance and Components ........... 6 Framing and Clearances 7 A. Select Appliance Location ..................... -7 B. Clearances.................................7 C. Framing Enclosure for LP Gas Supply System . - _ - .. _ 8 Gas Information 9 A. Fuel.......................................9 B. Gas Pressure ......................... .....9 C. Gas Connection ......................... ..-..9 D. High Altitude Installations ..................... 10 E. LP Gas Supply..............................10 5 Finishing 11 6 Appliance :letup 12 A. Burner Assembly........... _ ......... - ...... 12 B. Log Assembly .................... _ ..... .... 13 7 Operating Instructions 14 A. Before Lighting Appliance ..................... 14 B. Lighting the Appliance ..................... .. 15 C. After the Appliance is Lit ......................16 D. Frequently Asked Questions ............... I ... 16 8 Troubleshooting 17 9 Maintaining and Servicing the Appliance 18 10 Reference Materials 20 A. Service: Parts List ...........................20 B. Optional Components ........................22 C. Limited Lifetime Warranty .....................23 D. Contact Information ..........................24 Heat-N-Glo Lifestyles • Patio Campfire - 4004-001 Rev D • 07/05 3 9 D w to w 4'y • w n m N ti r+ Q, W N_ N w o O On o o Ct� o 0 0' 0 tz x x N (D r z fD �c ;v O r) Z n W D rm w C� r- v n m N 1 O Z m Heat-N-Glo Fireplaces, Inc. has demonstrated its innovative drive once again with the introduction of another Industry first, the Patio CampFyre. The Patio CampFyre gives homeowners the pleasure of enjoying a traditional campfire right out their back door with all the convenience of clean burning gas. Perfect for a patio or deck, the Patio CampFyre will light up the mood with its glowing CampFyre style logs, yellow flames and glowing embers. The base of the fire- place is surrounded by realistic looking river rock to add to the outdoor feel. The Patio CampFyre features Heat-N-Glo's CampFyre style logs strategically placed to create a realistic looking campfire and offer a great flame with 60,000 BTU Input/Hour (NG). It is simple to turn on and off and comes standard with a protective cover to safeguard it against the elements. And, because this unit is so portable, it can even be taken to almost any outdoor location where you want to enjoy a campfire. It's no longer necessary to pack up the kids and the tent to enjoy a beautiful campfire. Homeowners now have the ability to take the romance and convenience of a gas fireplace outside. It's a great way to bring the whole family together again. F__1 I . N.O _. �IpIyI I>e us'ciL'tLi iii( LL_ ?ilCi' fi Cll' i,r LAI o .h. t"`le�,�„ units �FC1FEtSa ile r..o?�!�ertCd after DLIYCIL!S,'.. SOMCi i, ' 4'WJkS I1U,lV rcrjl:irc _li,;lptor ibi lloo.k uE;. P riz,jn,TE ' �: P�rrlislic• Grtirtf5Fj1'e 11esi„!ja �' . �3:13elstctlf tl=.C;ur�r��re'!2lgirl, _ :yogrl:b '�. � `G'e�cirii�FrJ�er .- •... � : �'n£xrntiecJ G�lvta� ratad Kr��iisire' ;' _Zfes rt:G'e]�{t ed,2, Ski ely&St d' ..'gip:. SurYouirrled Gy .0 Ell ha12Ces A" Glanpf; fe's' Real sti'c lookisig'l4tver lock Xe l4tw dppaurunee - :..i.:;;SYiittdurll,�rotect$�ie G'araer � °;rfegriaxilAguirrar. . r■ L it -ri i'x- F.• �.id4. G��.�� -,• =r� :•rrm�rrarrrr�.s�:�,J F . r r- B-PATIO-CF REV.A Heat-N-Glo Fireplace Products, Inc. 6665 W. Hwy 13, Minneapolis, MN 55378 (612) 890-8367 s Fax 890.3525 - info@heatnglo:c6k:; , www.heatnglo.com tkae 1.0 INTRODUCTION Model PTO -DIY is a Decorative Gas Log Set for out- door use only. This appliance MUST NOT be used for cooking. WARNING: This appliance shall be used ONLY out- doors in a well -ventilated space and shall NOT be used inside a building, garage, or any other enclosed area. WARNING: This log set must NOT be installed in an unvented appliance. WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. The installation must conform with Local codes or, in the absence of local codes, with the National Fuel Gas CodeANSI Z223.1 orCAN/CGA-B149.1, National Gas Installation Code or CAN/CGA-B149.2, Propane Instal- lation Code. The appliance and its individual shut off valve must be disconnected from the gas supply piping system dur- ing any pressure testing of the system at test pres- sures in excess of 1/2 psig (3.5kPa). This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa). The following clearances to combustible construction must be maintained: Bottom - 0 inches, Sides (all around)-24 inches (610 mm), and Top-8 feet (2.4 m). Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. Do not locate appliance where it can get excessively wet. Do not use this appliance if any part has been under water. Immediately call a qualified service tech- nician to inspect the unit and to replace any part of the control system and any gas control which has been underwater. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ig- nition. • Young children should be carefully supervised when they are in the area of the appliance. • Clothing or other flammable materials should not be hung from the appliance, or placed on or near the appliance. • Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance. Installation and repair should be done by a quali- fied service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent clean- ing may be required as necessary. It is impera- tive the control compartment, burners and cir- culating air passageways of the appliance be kept clean. • Inspect the fuel supply connection (including the hose for LP models) before each use of the appliance. • If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the appliance being put into operation. • The pressure regulator and hose assembly sup- plied with LP models must be used. Replace- ment pressure regulators and hose assemblies must be those specified in this manual. • The LP gas supply cylinder used with LP mod- els must be constructed and marked in accor- dance with the specifications for LP -gas cylin- ders of the U.S. Department of Transportation (DOT). • Cylinders must be stored outdoors in a well -ven- tilated area out of the reach of children. Dis- connected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area. • Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural gas line or -LP gas cylinder). • The LP gas cylinder supply system must be ar- ranged for vapor withdrawl. • The LP -gas cylinder used must include a collar to protect the cylinder valve. • When an LP model is not in use, the LP -gas must be turned off at the supply cylinder. -4