Loading...
BMCH2016-036478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BMCH2O16-0364. Property Address: 61620 TULARE LN LN APN: 764550059 Application Description: BREWER RESIDENCE / HVAC Property Zoning: Application Valuation: $4,026.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 aw DESIGN & DEVELOPMENT DEPARTMENT BUILDING: PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 686310. Date:=l0a Ile Conte tractor ��% ` VOICE'(760) 777-7125 FAX (760) 77.7-7011 INSPECTIONS (760) 777-71S3 Date: 10/11/2016 C C) s: 0 M m O O m HARRISON ENTERPRISES INCr0 31170•RESERVE'DRIVE THOUSAND PALMS, CA 9227_x6 (760)343-7488 Llc. No.: 686310 ----------------------------------- WORKER'S COMPENSATION DECLARATION Owner: :JAMES BREWER 61620 TULARE LN LA CtUINTA, CA 92253 Contractor: � O C k� E,:; GP�RA rATR� � rn I hereby affirm under penaltyof perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided fog by Section 3700 of the Labor Code; for the performance of th • ork for which this;permrt is'issued. I' -have and will mamtam,workers' compensation insurance, as required by Section 3700 of the Lab'oc Code; for;the performance;of the work for which this permit is issued. �My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION. Carrier: INSURANCE COMPANY OF THE WEST Policy Number.VVSD5031658 I hereby affirm under penalty of perjury that I am exempt from the Contractor's State • • .License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any I certify that in the performance of the work for which this permit is issued, I city or county that requires a permit to construct, alter;'improve, demolish, or repair shall not employ any person in any manner so as to become subject to the workers' any structure; prior to its issuance, also requires the applicant for the permit to file a compensation laws of California; and agree that, if I should become subject to the signed statement that he or she is licensed pursuant to theprovisions of the ` workers compensation provisions of Section 3700 of the Labor Code, I shall forthwith Contractor's State License Law (Chapter 9 (commencing with Section 7000)'6f•Division comply with those provisions. 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of -Section 7031.5 by any applicant for a Dat_ permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: WA (_) I, as owner of the property, or my employees with wages as their sole AN compensation, will do the work, and the structure is not intended or offered for sale. ON (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not CO apply to an owner of property who builds or improves thereon, and who does the work INT himself or herself throu h his or her own em to ees rovided that the im rovements RNING:`FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, D SHACL'SUBJECT AN•EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO EHUNDREDrTHOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF MPENSATION; DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, EREST, AND ATTORNEY'S FEES. ' g P Y ..P P are not intended or offered for sale. If, however, the:building or improvement is sold' APPLICANT.ACKNOWLEDGEMENT within one year of completion, the owner -builder will have the burden of proving that IMPORTANT: Application.is hereby made�to the Building Official for a permit subject to he or she did not build or improve for the purpose of sale.). the conditions and restrictions sef-forth on this application. (_) I, as owner of the property, am exclusively contracting with licensed contractors 1..Each person upon:.whose behalf this application is made, each person at whose . to construct the project. (Sec. 7044, Business and Professions Code: The Conf�actors' request and for, whose, benefit work is performed under or pursuant to any permit State License Law does not apply to an owner of property who builds or improves -issued as a result of.this application; the owner, and the applicant, each agrees to,, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to . • shalt defenii;,indemnifij and Hold harmless.the City of La Quinta, its officers, agents, and the Contractors' State License Law.). employees-forvany act or omission related to the work being performed under or (_) I am exempt under Sec. . B.&P.C. for this reason following issuarice'of this permit: Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 2: Any permit issued as a result of this application becomes null and void if work is not commenced 'within 180 days from hate of issuance of such permit,. or cessation of work for180 days'will,subject permit to cancellation. I certify that�l have read "this application and state that the above information is correct. I agree to'comply with all city and "county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date:,—_�:O 11 l(o r. Signatures(ApplPcantor;Agenf):°'°=' Application Number: BMCF 2016-0364 Property Address: 61620 TULARE LN LN APN: 764550059 Application Description: BREWER RESIDENCE / HVAC Property Zoning: Application Valuation: $4,026.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 Date: 10/11/2016 Owner: JAMES BREWER 61620 TULARE LN LA QUINTA, CA 92253 Contractor: -HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS, CA 92276 (760)343-7488 Llc. No.: 686310 Detail: COIL CHANGE OUT - SPLIT SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) T&BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2013 CALIFORNIA BUILDING CODES .. • I DESCRIPTION ACCOUNT QTY AMOUNT BSAS 561473 FEE 101=0000-20306:' . 0 $1.00 Total Paid for. BUILDING STANDARDS ADMINISTRATION BSA:' $1.00 DESCRIPTION ACCOUNT.'' QTY AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT- REPAIR/ALTERATION PC —T—=] ;,101-0000742600: '.. 0 —I $5.07 +Total Paid for CHANGEOUT: $17.74 DESCRIPTION 7, .,ACCOUNT,`_,` QTY AMOUNT PERMIT ISSUANCE = . %(101-0000-42404. 0 $96.27 ,' ;yTotal Paid for PERMIT ISSUANCE: $96:27 Bin. # . . C�ty::of La.. QurnIM Bq((4109 Bf,Sar&y Dh&.6, `- P.O. Box 1504,78-495 Calle .T'arnpfco IA Qu hdn CA 92253 -:(766)777-7012 Building Permit A J: cation aril Tracking Sheet Permit # Project Address: 61620 Tulare Lane Ownes'sName:. Jim & JannaBrewer A. P, Number. 'Address: 61620 Tulare Lane Legal Description: Contractor. General Air Conditioning & Plumbingz--r" City, ST, Zip: La Quinta, CA •92253 Telephone:-• 760=61.9-3924 Address: 31170 Reserve Drive Project Description: Replace 4 ton Coil City, ST, Zip: Thousand Palms, CA 92276 Telephone: 760-343-748$ State Lic. # : 686310 City Lia #.: Arch., Engr., Designer Address: City., ST, Zip: Telephone: m Vii! »� ,� :i'Construction Type: Occupancy: State Lic. #: Prolect•type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Steven Schnierer Sq. Ft.: #Stories: #Units: Telephone # of Contact Person: 818-7-35-7876 Estimated Value of project. $4;026.00 . APPLICANT: DO NOT.Wi31TE BELOWTHIS,'LINE # Submittal Req'd Reed TRACKWG PERMIT FEES Plan Sets Plan Check submitted item Amount Structural Calm Reviewed, ready for corrections Pian.Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance Tide 24 Calcs. Plans picked-up Construction Floodplain plan Plans resubmitted Mechanical Grading plan 2'! Rtview, ready for correctiousfissue Electrical Subcoutactor List Called Contact Person Plumbing Grant Deed Plans picked up $:M.L H.O.A. Approval -Plans resubmitted Grading IN HOUSE:- ''d Review, ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A:I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees STATE OF CALIFORNIA ALTERATIONS - HVAC f— CEC-CFIR-ALT-04-E Revised 03/15 CALIFORNIA ENERGY COMMISSION X00' CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E Alterations - HVAC CZ 2, and.8-15 (formerly CF4R-ALT-HVAC) (Page 1 of 1) Site Address: Enforcement Agency: Date Prepared: Permit#: 61620 Tulare Lane City -Of La Quinta October 11, 2016 Equipment Type Equipment Efficiency New Ducting, Plenums, Lineset: Conditioned Thermostat Required R -value Floor Area (sq ft) ❑ Packaged REvaporator Coil 80%AFUE COP ❑ R-6 (CZ 2, 8-13) Ducting Served by system Setback System ❑ Condensing Unit ❑ R-8' (CZ 11, 14, 15) Ducting 1,500 sgft (If not already ❑ Split System ❑ Compressor SEER HSPFpresent ❑ R 6.(all CZ's) Plenums must ❑ Mini S Split p ❑ Lineset EER 13 R-5 or R7.5) Lineset° be installed) ❑ Furnace ❑TXV HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no -hand filled forms allowed) and a copy left on site. R1. HVAC Changeout/Repair Required Compliance Documents to`be left on site for Final: All Equipment, CF111-ALT-02-E Condenser Unit, Evaporator Coil, CF2R:. MECH-03, MECH-20-HERS, MECH-(23 or 24)' -HERS, MECH-25-HERS' Compressor, TXV, Lineset, CF3R: MECH-20-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS' Air Handler/Furnace' (Can include new ducting) Installer Requirement: Duct leakage (:L15%, or <10% to outside, or seal all accessible leaks), Air Flow a 300 CFM/ton, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts3 CFIR-ALT-02-E including Mini Split CF2R: MECH-01, MECH-20-HERS,'MECH-22-HERS, MECH-(23 or 24); HERS', MECH-25-HERS' CF3R: MECH-20-HERS; MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25=HERS' Mini Splits require CFIR-ALT-02-E, CF211WECH-01, and (CF2R-CF3R) MECH-25-HERS Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge ❑ 3. All New Duds with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CRR -ALT -02-E replaced: Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Compressor, TXV, Lineset, Furnace' CF3R: MECH-20-HERS, MECH-(23 or24)-HERS;.MECH-25-HERS Installer Requirement: Dud leakage < 6%, Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts3 CFIR-ALT-02-E, CF2R: MECH-20-HERS, CF3R:. MECH-20-HERS Installer Required to: Duct leakage L15% at, < 10% to outside or; or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc. ' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25 ' All New Ducts is when.at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) ° R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5-2T-2%", 2.5-3T=2%", 3.5 to 4T -2%", -ST -4W' Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and, performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Date Signed: License: Steven Schnierer Ocotber 11, 2016 686310 Company: Address: - City/State/Zip: Phone: General Air Conditioning 31170 Reserve Drive Thousand Palms, CA 92276 760-343-7488 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300