BPOL2016-0116.787495 CALLE TAMPICO
LA QUINTA,-CALIFORNIA 92253
Application Number:
BPOL2016-0116
Prope rtyAddress;
61704TULARE LN LN
APN:
764550053
Application Description:
ANGELO ARIENDO / POOL
Property Zoning:
Application Valuation:
$12,000.00
Applicant:
CLASSIC POOLS & SPAS
79-461 AVENUE 40
INDIO, CA 92203
DESIGN & DEVELOPMENT.DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions.of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No. 634338
Date
Contractor:
OWNER -BUILDER DECLARATION '
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5 Business,arid Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant.for the permit to file a
signed statement that he or she is licensed pursuant.to-the provisions of the
.Contractor's State License Law (Chapter 9 (commencing with Section•7000) of Division
3 of the Business and Professions Code) or that he or'she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does no
apply to an owner of property who builds or improves thereon; and who does the wort
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If,. however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of. sale.►.
(� I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projectswith a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am'exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/4/2016
Owner:
CHARLENE BLACKWELL
92253
D
Contract o : AUG o 4 2n
CLASSIC P OLS '& SPAS —
79-461 A ENUE 40 CITY OF IAQUINTA
INDIO; CA 2203
COMMUNITY DEVELOPMENT DEPARTMENT
(760)345-8302
Llc. No.: 634338.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent toself-insure for workers'
compensation, as provided f6f by Section'3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Ihave and will -maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation' insurance carrier and policy number are:
Carrier: EVEREST NATIONAL, I NSU RANCE COMPANY Policy Number: 7600014354
I certify that,in the performance of the work for which this permit is issued, I
shall not employany person in any manner so as to become subject to the workers'
compensation laws -of California, and agree that,`if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: ' Applicant
WARNING: FAILURE TOSECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND'S .ALL SUBJECT'AN`EMP1. LOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR -IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
, AP PLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby.made tothe`Building Official for a permit subject to
the,conditions and restrictions`setforth on this:application.
1..Each person+upon whose behalf this application is made, each person at whose
request andfor,;;hose benefit work is performed under or'pursuant to any permit
issued as a'result of this'application , the owner; and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quirita, its officers, agents, and
employees,for any actor omission related to the work being performed under or
following issuance of -this permit.
2., Any permit -issued as a result ofthis application becomes null and void if work is
not commenced'within 180 -days frorn:date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify, 'that I have_read this application and state that the above information is correct.
I agree to comply with all 6ty4nd county ordinances and state laws relating to building
construction, and hereby authiorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
CLASSIC POOLS & SPAS
79-461 AVENUE 40
INDIO, CA 92203
BPOL2016-0116
61704TULARE LN LN
764550053
ANGELO ARIENDO / POOL
$12,000.00
Owner:
CHARLENE BLACKWELL
, 92253
Contractor:
CLASSIC POOLS & SPAS
79-461 AVENUE 40
INDIO, CA 92203
(760)345-8302
Llc. No.:.634338
Date: 8/4/2016
Detail: SPA, BBQ, AND 7 LF EQUIPMENT ENCLOSURE AT REAR YARD [DENISE POELTLER ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT
ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA BUILDING CODE.
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE '101-0000-20306 0 $1.00
Total Paid for BUILDING,STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$24.17
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
Total Paid for ELECTRICAL: $48.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/FENCE -FIRST 100 LF:
101-0000-42404
0
$47.86
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/FENCE - FIRST 100 LF PC
101-0000=42600
0
$60.91
Total'Paid for FENCE OR -FREESTANDING WALL: $108.77
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SWIMMING POOL/SPA
101-0000-42404
0
$181.29
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SWIMMING POOL/SPA PC
101-0000-426000
$98.62
Total, Paid for POOL/ SPA: $279.91
Description: ANGELO ARIENDO / POOL .
Type:'POOL Subtype: Status: APPROVED
Applied.,8/4/2016 RSE
Approved: 8/4/2016 _DCL
Parcel No: 764550053 Site Address: 61704.TULARE LN LN LA QUINTA,CA'92253
Subdivision: TR 36023-7 Block_: Lot106
Issued:
Lot. Sq Ft:.O Building Sq Ft: 0, Zonirig:
Finaled: .
Valuation: $12,000.00 Occupancy Type:.. ConstEuction Type:
Expired:
No. Buildings: 0 :No Stories: 0 _ No' Unites: 0.
betails: SPA, BBQ, AND 7 LF EQUIPMENT ENCLOSURE AT REAR YARD'[DENISE POELTLER ENGINEERING] THIS PERMIT DOES.'NOT INCLUDE
E461PMENT•ENCLOSURE ALARMS`AND BAR RIERS�REQUIRED 'TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA
BUILDING CODE...
VE CALL DUANE CLAYTON' f 8/4%2016
CONTRACT CLASSIC POCILSA SPAS' 79461 -AVENUE 40.,
_. yz: - - _ _ - m
., ^fin ssn ZrY? F a .t eE�iliif11111 : lipl�... ,,i Ad >. H'�ti;nTt"rLl
I' II Y N qr �,� ',n 1 <f �lal` n'' ; r _y^"� r ;9 . Kala,.. v..''I �I,rll �II� !Il(h ,�' 'lN! si°il IIG 14 : fl •�,•� .,.w,,, '.kms, .s
4F < r.- � � a 0 FINA'NCIIAL INFUItN1ArION ri. ..< :.
a'iti.,',�°- :a; ,�I
Hz:w >•�'+ Sx+v.�.Sa'Y.',`•^'�_
nl I II 7I rj `r��'^`ny^s p'n4Tii'�j�'+ ,�Il't(- M1!
t~:.4�, le. ids 4 ! a. {..,�«�';
: ._
""?f
-.»,''3
Printed:Thursday,2016 of
..........
It I P'T
CCO.,
UNT'- -A
1
TE
%"RE El
7�
BSAS SB1473 FEE
101-'0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION .
$1. 00 $0.00
BSA:
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
DEVICES, FIRST, 20 PC.
101-0000-42600
0
$24.17
$0.00
Total Paid for.ELECTRICAL: .$48.34 $0.00
WALL/FENCE - FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
WALL/FENCE - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDINGWALL: $108.77 $0.00
SWIMMING POOL/SPA
101-0000-42404
0.
$181.29
$0.00
SWIMMING POOL/SPA
101-0000-42600
0
$98.62
$0.00
PC
Total Paid for POOL SPA: $279.91 $0.00
INSPECTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
....................
'''BOND"INFORMATICIN
--- - -- --------- -
Printed: Thursday, August 04, 2016 4: . 05:05 PM 2 of 3 cmw,,YsTrms
VivY, MIN I
"t, W
'll R
M
M ON
"E, 112111111.1112,
WttAchTeM�Type gi�TEQ
, k,m=
.
6,
'"F.".TTI70H'
-j -RIRO3T
_
as MM=
5M
NOSES=
DOC
8/4/2016
'DUANE CLAYTON
HOA APPROVAL
0
APPROVAL.pd
a
4
Printed: Thursday, August04, 2016 4:05.:05 PM 3 of 3 -RWSYSTEMS
Bin #
City of La Quints
Bugag 8i Safety DMdon
Permit # P.O. Box 1504, 78-495 Cafe Tampon
La Qtdnta,'CA 92253 - (760) 777-7012
I I Building Permit Application and Tracking Sheet
Pmjed Address: �l C� �'�iG Y e 1� . Owner's Name: elo a i �lc�o .
A P. Number :► --1--T.IGre x 1 Yl .
mo tion: Cilr;ST. Zip: �LCA �1i�G, C4 9aokl�;_3.
CowMCt - S ► ' d Telephone C —, 32 — �J s I c�
Adam: V u
-90 Proj«x I)estziption
City. ST, zip
0
Telephone. 4�
State Lia #: (Q�`�+ City Lia #:
•rte EngrTv -• 1 \�. 1
sty. ST. Zip: m v
Telephone. 4 1
Coastntction Type: OocapancT
State Lic. #:
Name of Contact Person:-40-val
Project type (cuele one): New Add'n Atter Repair Demo
,, -
Y.LJU� ', ue S9. # Stories: #Unite
Telephone # of Coosa Person —
-- Es&m ted Valu of Proj Z U .0
APPLICANT: DO NOT WRITE BELOW THlS.UNE
# Submwal Req!d Reed 'IRACTMG PERMIT F131:S
Plan Seb Plan Ckeck abmitted Itnu Mowat
Structural Cales.
Reviewed, ready for eormlioas
Ptah Check Deposit
IV= Cala.
Called Contact Person
Pian Check Balance
Title 24 Cala.
Plana pielked up
Comtruetion
Flood min tin
Plans resubmitted
Mechanical
Grading plan
28! Review, ready for eorrec6oasAsaue
Mcct teal
Subeoata tDr IILt
Called Contact Person
Plumbing
Grant Dead
F:
Plans picked up
SM.L
ILO .& Approval
Plans resubmitted
Grading
1N HO[ISBi- --
- --
'�' grew, ready for eorreedonsPassne
Developer Impact Fee
Winning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
School Fen
Total Permit Fees
•
•
•
NOTE:
THE EQUIPOTENTIAL BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED
SURFACES FOR 3 FEET
HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL.
ELECTRICAL LOAD CALC.
9.6 - 8.8 1-1/2 HP 22 AMPS MAX LOAD - VARIABLE SPEED PUMP
1.2 - 2.1 LIGHT
NOTE:
1. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED.
2. MASONRY EQUIPMENT WALL SHALL BE BUILT PER CITY STANDARD SPECIFICATIONS
3. ALL GFI UNITS WILL BE WEATHER AND TAMPER PROOF
4. ALL OUTLETS SUPPLIED BY SINGLE-PHASE, 15A AND 20A, 125V OR 240V BRANCH
CIRCUITS FOR SWIMMING POOL
PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION.
5. PROVIDE 36' WORKING CLEARANCE FOR THE POOL EQUIPMENT MOTORS ARE
REOLIZI3.
POOL SAFETY BARRIER:
EXIT ALARMS
SELF-CLOSING
SELF -LATCHING DOORS
SPA TO BE EQUIPPED WITH WITH ANTI -ENTRAPMENT DEVICE (SEC. 1404 FEDERAL SWIMMING
POOL AND SPA DRAIN COVER STANDARD)
2013 CALIFORNIA STANDARD BUILDING CODE (BASED ON 2006
IBC)
2013 CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC)
2013 CALIFORNIA PLUMBING CODE (BASED ON 2009 UPC)
TITLE 24, PART 5
2013 CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC)
2013 CALIFORNIA ENERGY EFFICIENCY STANDARDS
SAFETY RULES:
ALL ANTI -ENTRAPMENT COVER
INSTALLATION MEETING CURRENT
STANDARDS OF THE AMERICAN SOCIETY
FOR TESTING
AND MATERIALS OR THE AMERICAN
SOCIETY OF MECHANICAL ENGINEERS
(ASME)
ELECTRICAL:
EQUIPOTENTIAL BONDING REQUIREMENTS
SHALL BE INSTALLED TO ELIMINATE
VOLTAGE GRADIENTS IN THE POOL AREA
AS PER CEC ART 680.26
OWNER RESPONSIBILITIES:
OWNER TO:
1. DETERMINE THE APPROXIMATE ELEVATION OF POOL
AND SPA AT LAYOUT ON DAY OF EXCAVATION
2.TAKE NOTICE THAT POOL AND EQUIPMENT,
LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL
BUILDING DEPARTMENT AT THIS TIME OF ISSUANCE OF
PERMIT.
3.WET DOWN GUNITE AT LEAST ONCE DAILY FOR
SEVEN DAYS AFTER GUNITE IS SHOT
4.AGREE THAT CLASSIC POOLS AND SPAS IS NOT
RESPONSIBLE FOR UNDERGROUND CONDITIONS OR
OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS,
DRIVEWAYS, LAWNS, DRIVEWAY, OR OTHER ITEMS IN
THE ACCESS AREA.
5.SEE THAT ALL FENCING, GATES AND GARAGE DOORS
MEET LOCAL CODES FOR POOL ENCLOSURE PRIOR TO
PRE -PLASTER INSPECTION.
&FILL POOL IMMEDIATELY AFTER PLASTER (FOLLOW
INSTRUCTIONS -DO NOT USE RUBBER HOSE)
TTAKE NOTICE THAT THIS DRAWING IS THE SOLE
PROPERTY OF CLASSIC POOLS AND THAT ANY USE
WITHOUT WRITTEN PERMISSION OF CLASSIC POOLS IS
PROHIBITED BY LAW.
OWNER APPROVES PLAN, POOL, AND EQUIPMENT
LOCATIONS AND HAS READ THE RESPONSIBILITIES AND
NOTICES ABOVE.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
iPPRO"VED
FOR CONSTRUCTION
DATE J);Alb BY 4l ,
SPA SPECIFICATIONS
1
SPA WATER LINE TILE TO BE SELECTED
2
SPA PEBBLE STONE COLOR TO BE SELECTED
3
STEP SIZES TO BE NEGOTIATED
4
SPA COPING TO BE SELECTED
5
STACKING STONE SPILLWAY
6
SPA LIGHT
7
PAVERS TO BE SELECTED
®
ARTIFICIAL GRASS TO BE SELECTED
AREA SPECIFICATIONS:
A
SPA SURFACE
150 S.F.
B
SPA PERIMETER
88 L.F.
C
SPA COPING
92 L.F.
D
SPA SPILLWAY
8 L.F.
E
GAS LINE
170 L.F.
G
ELECTRICAL LINE
1,70 L.F.
H
PAVER AREA
425 S.F.
I.
GRASS AREA
290 S.F.
30 AMP SERVICE PANEL
1" UL CODUIT
10 AWG WIRE
JET PUMP 1-1/2 HP
2" PLUMBING
2" GAS LINE P.E.P.
NO OUTDOOR EXISTING LIGHTING
2 HP FLOW RATE 140 GPM
1-1/Y FLOW RATE 126GPM
CIRC PUMP 2HP LOW & HIGH
NO OVERHEARD UTILITIES LINES EXIST
PENTAIR EQUIP. MEETS ALL REGULATION CODES
STACKING STONE
CASCADE TO BE -20'1
3' DRAINS LEAC
TO STREET
BBO TO BE—
rLONG X 3'WIDE
X 38'HnH
SPA TO BE EQUIPPED WITH ANTI -ENTRAPMENT DEVICE (SEC. 1404 FEDERAL
SWIMMING POOL AND SPA DRAIN COVER STAND)
NOTE:
ALL POOL HEATER INSTALLATIONS REQUIRE A
CF2R-PLMB-06-E FORM TO
BE COMPLETED AND SIGNED BY THE INSTALLER OFiRECORD AND
SUBMITTED TO THE
BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL.
PROVIDE LOCATION OF ANTI-ENTRAPMENTNORTEX COVERS MEETING
CURRENT
STANDARDS OF HE AMERICAN SOCIETY FOR TESTING AND MATERIALS
(ASTM) OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
(ASME).
(ASTN) IDENTIFY A MINIMUM 3FT. SEPARATION!BETWEEN ALL DRAINS
AND NOTE HYDRAULICALLY BALANCED.
3' DRAINS LEADING
TO STREET
PANEL
TULARE LANE
Important Notice - Underground Service Alert
Section, 42t%zr7 of the Government Code requires a
Dig Alert Identification Number to be tissued before
a 'Permit To Excavate' will be valid For your Dig
Alert Identification Number call Underground Service
Alert TOLL FREE at 1-800-227-2600 two working
days before you dig.
Q
Z 0
0 U)
W J
00
� U
O�
oQ
W J
OU
Z LL
=O
U F-
0 Z
W W
Uz
D Z
oo
OU
W
W
W _
LU
F_ W
0 (n
Z W
IX
X X
Q W
O F-
UO
LL =
H
W
as
Z W
<0
C/)�
� Q
Z
g�
LL
W
Z
(1)Z
Z Q
g�
a0
U5 C
I=- O
DATE: 7/19/16
•
.7
P-1
0
•
J
SIN
-
W
Z
N
0
0
M
pZ
W
m
C
O-.
0
W
DATE: 7/19/16
•
.7
P-1
0
•
J
Ill
W
Z
N
0
0
M
pZ
W
m
C
O-.
0
W
�v
n/
FO
O
LliQ
Q
U)
O
F -
Z
Z
W
z
~
O
0
O
Z
Q II
J
W
W
F_
J
0 Q
W
0 U
W
V)
M
DATE: 7/19/16
•
.7
P-1
0
•