Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0102
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO, CA 94402 4.�wQ�rw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2015-0102 52380 SILVER STAR TR 767640016 19.08kW PV SYSTEM - (72) 265W PANELS/(2) INVERTER $42,166.80 AUG 0 4 2015 I CITY CF LA QUINTA COMWNITY JEVELOPiAcNT DEPARTP.IENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License CI ss: C B C10A Licens88 104 Dater LID Contractor: OWNER -BUILDER DECLARATIO I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who'does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-; 125 FAX (760) 777-:011 INSPECTIONS (760) 777-:153 Date: 8/4/2015 Owner: JAMES STARKWEATHER 52380 SILVER STAR TR LA QUINTA, CA 92253 Contractor: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for worlers' Wcompe a ion, as provided for by Section 3700 of the Labor Code, for the perfornance of t4 for which this permit is issued. I have and will maintain workers' compensation insurance, as requirec by e 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is is::ued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37 of th L bor Code, I shall forthwith comply, i h th se( provisions. Date: V Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATI N OVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP'TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permt issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if wotk is not commenced within 180 days from date of issuance of such permit, or cessati'3n of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above formation is correct. I agree to comply with all city and county ordinances a d ate s relating to bidding construction and hereby authorize representatives of his ity niter upon theabove mentW ection purposes. Date:nature (Applicant or FINANCIAL .• l. $ DESCRIPTION e "ACCOUNT _ QTY ; AMOUNT .4-, AID ` : P PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 �. PAID BY, h s... 'METHOD CHECK # CLTD BY'`' Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 `r DESCRIPTION ' :< , ACCOUNT& ` r -QTY AMOUNT- PA10" PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID.BY - � ' , , , s;; METHOD ' , • ;, � ...RECEIPT # _, <n.f ,. -, CHECK # r , , , 4 CLTD BY DESCRIPTION °rACCOUNT t` `QTY #AMOUNT "' _ PAID ,. PAID"RATE. PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 (i, e} PAID BY a METHOD ".4 �'a s .RECEIPT # , CHECK #� Y wCLTD BY- Total Paid forELECTRICAL: $48.34 $0.00 Total DESCRIPTION `_ '' ° �` d`,,;; ACCOUNT :. QTY AMOUNT .,3 �a . PAID " PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY 4` METHOD ,:.� .RECEIPT # _' CHECK # , CLTD BY ; Total Paid forPERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 INSPECTIONS -SEQIDINSPECTION INSPECTORk COMPLETED' `REMARKS NOTES :AX .,DATE DATE 'SOLAR FINAL" BLD ....... ... ... FINANCIAL INFORMATION .-REVIEWS STATUS... REMARKS CLTD DESCRIPTION ACC UNT; O AMOUNT , ' '�,, PAID DATE ECEIPT # CHECK #METHODPAID BY NOTES By. BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-00.00-42403 0 $24.17 $0.00. APPROVED 1 W FIRST 20 PV. SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid forELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: $142.19 $0.00 INSPECTIONS -SEQIDINSPECTION INSPECTORk COMPLETED' `REMARKS NOTES :AX .,DATE DATE 'SOLAR FINAL" BLD ....... ... ... RETURNED D .-REVIEWS STATUS... REMARKS ,-REVIEW TYPE REVIEWEk, SENT DATE DUE DATE DATEm. NOTES NON-STRUCTURAL - LUIS URIBE 7/13/2015 7/20/2015 7/ . 21/201S REVISIONS REQUIRED NEED TO SPECIFY PROCESS OF COMBINING 1 W STRINGS. EX: FUSED COMBINER BOX NON-STRUCTURAL- LUIS URIBE 7/24/2015 7/31/2015 8/3/201S. APPROVED 1 W ATTACHMENTS Printed: Tuesday, August 04, 2015 12:01:20 PM 2 of 2 CRwlysTrms Description: 19.08kW PV SYSTEM - (72) 265W PANELS/(2) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 7/13/2015 EVA Approved: 8/4/2015 EVA Parcel No: 767640016 Site Address: 52380 SILVER STAR TRLA QUINTA,CA 92253 Subdivision: TR 31202-1 Block:- Lot: 57 - Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $42,166.80 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 _ NOTES Details: 19.08kW SOLAR ARRAY - (72) 265W KYOCERA PANELS W/ (2) FRONIUS PRIMO 8.2-AFCI INVERTER. DERATEING MAIN PANEL BREAKER FROM 200A TO 175A [1275SF] 2013 CALIFORNIA ELECTRICAL CODE. 22 ` A77-77-77777777- pplied to Approved - Printed: Tuesday, August 04, 2015 12:01:20 PM 1 of 2 • SYSTfiNS CHRONOLOGY CHRONOLOGY TYPE- STAFF NAME ACTION DATE COMPLETION DATE ` _ NOTES ,.: E-MAIL LUIS URIBE7/21/2015 7/21/2015 SENT ELENA AN EMAIL LETTING HER KNOW PLANS ARE READY FOR CORRECTIONS. E-MAIL LUIS URIBE 8/3/2015 8/3/2015 SENT ELENA AN EMAIL. PERMIT IS READY TO BE ISSUED. PLAN CHECK PICKED UP STEPHANIE KHATAMI 7/21/2015 7/21/2015 ELENA RESUBMITTAL PHILIP JUAREZ 7/24/2015 7/24/2015 COULD NOT FIND FOLDER PUT ON LUIS DESK CONTACTS -,NAME TYPE F: ; ` s NAME,: ADDRESS1 - CITY m STATE. ZIP : PHONE. ; w FAX EMAIL APPLICANT. SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 mplasse@solarcity.com CONTRACTOR SOLARCITY CORPORATION' 3055 CLEARVIEW WAY SAN MATEO CA 94402 mplasse@solarcity.com OWNER JAMES STARKWEATHER 52380 SILVER STAR TR I LA QUINTA CA 92253 Printed: Tuesday, August 04, 2015 12:01:20 PM 1 of 2 • SYSTfiNS i -ABBREVIATIONS` ELECTRICAL NOTES JURISDICTION ,NOTES L .., A AMPERE x 1. THIS'SYSTEM IS..GRID=INTERTIED VIA A ALL CONSTRUCTION SHALL' COMPLY WITH THE 2013 AC, ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. O BLDG BUILDING � - � 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. - � CALIFORNIA BUILDING, RESIDENTIAL, .MECHANICAL, - CONC CONCRETE - 3. A NATIONALLY—RECOGNIZED TESTING ELECTRICAL, PLUMBING, ENERGY, NTA!AND MUNICIPAL BUILDING CODES AND THS - - DC DIRECT. CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN . LA QUINTA MUNNICICGREEIPAL CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING; 4. t WHERE ALL TERMINALS UF' IHE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, V FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDSPER ART. 690.17. c• ` GEC GROUNDING ELECTRODE CONDUCTOR 5.• EACH UNGROUNDED CONDUCTOR'OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY - HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT. MAX POWER COMPLY• WITH ART. 250.97; 250.92(B). ; Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER = kVA KILOVOLT AMPERE BUILDING OR ARE 'RUN IN METALLIC RACEWAYS OR kW _• KILOWATT - ENCLOSURES TO THE FIRST ACCESSIBLE • DC ��•++ LBW LOAD-BEARING WALL` - DISCONNECTING MEANS PER ART. 690.31(E). CITY OF LA QUINTA ' MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN ' ` - �--- - --� t BUILDING& SAFETY DEPT.. (N) • . NEW RELIEF -AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL - UL LISTING. r - - APPROVED F _ .T NTS NOT T0. SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE-+. FOR CONSTRUCTION # - OC ON CENTER. UL—LISTED LOCATION PROVIDED BY THE r PL PROPERTY- LINE x . MANUFACTURER USING UL LISTED GROUNDING 001 ; POINT OF INTERCONNECTION- - HARDWARE. ;: ,._ ;? , ' " DA 3 iS BY PV PHOTOVOLTAIC • 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE _• ' . BONDED WITH EQUIPMENT -,GROUND CONDUCTORS. _ .,. - t•' S ' STAINLESS STEEL _ -'`t - - -•'- _. _, STC `STANDARD TESTING CONDITIONS - . •�y' � - - ....^�•--_..,.:....,..._ - TYP TYPICAL .. y UPS UNINTERRUPTIBLE POWER SUPPLY - V VOLT Vmp VOLTAGE AT -MAX POWER - -VICINITY MAP , - INDEX Voc VOLTAGE AT OPEN CIRCUIT - t _ ` W•, WATT 3R 'NEMA 3R, RAINTIGHTs ET P R sem,+ V1 COVER SHE V2 SITE PLAN PV3 STRUCTURAL VIEWS _ PV4. UPLIFT CALCULATIONS LICENSE GENERAL NOTES ;: ' r VS " PV5 THREE LINE DIAGRAM ,' { PV6 ONE LINE DIAGRAM , ' .'Xr• �. �,. " ., PV7 ELECTRICAL CALCULATIONS • CA #' 888104 • 1. ALL WORK TO BE DONE TO THE 2013. ti .°, '' PV8 ELECTRICAL LOAD CALCULATIONS C-10' w CALIFORNIA BUILDING CODE AND THE' 2013. ,. _ j ` _ _ • _ CALIFORNIA RESIDENTIAL CODE. Cutsheets Attached y 2. ALL ELECTRICAL WORK SHALL COMPLY WITH ' "" �= ho E ; "` THE 2011 NATIONAL ELECTRIC CODE AS AM_ ENDED BYOlt ' THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP-SOLAR 3 _ - ?► ti �' - r REV BY DATE COMMENTS AHJ: La QUlnta w j w' 1+ ► , REV A NAME DATE COMMENTS 'UTILITY: Imperial Irrigation District • " = x x x x - r JB -922,391-7 0 0 PREMISE DWNER , DEIPn«�: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER• ' STARKWEATHER, JIM ` STARKWEATHER RESIDENCE BENTAINED,SHALL NOT BE USED FOR THE , - sola,ecity. BENEFIT OF•ANYONE EXCEPT SOLARaTY INC., MOUNTING SYSTEM: a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 52380' SILVER STAR TRAIL► 19.08 KW : PV -ARRAY , PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN.CONNECTION WITH MODULES • ' LA QUINTA, CA 92253 : - . -. " THE SALE AND USE OF THE RESPECTIVE - (72) KYOCERA # KU2656ZPA APN: 767640016 I •3055 Son Mateo, eCA94402 - w Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: - PAGE NAME: SHS' REV: DATE: 7:(650) 638-1028 F:(650) 638-1029. PERMISSION OF SOLARCITY INC 760 217 3333 P V _ 1 -7/8/201,5 - 886 FERTER: ' -Primo 8.2 ' - • - �' ) COVER SHEET - - - -( -SOL-CITY (ass -2489) wwwsdorcitycom CITY QE LA QUINTA BUILDING & SAFEPT, APPROVED FOR CONSTRUCTION DATE 93 "Y------------ �- TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V —METER#1B45R-102642 "PROPOSED BI—DIRECTIONAL METER#-- CUTLER HAMMER — AC DISCONNECT: 1 FT FROM MAIN PANEL — INVERTER: FRONIUS PRIMO 8.2 ,IOB NUMBER JB -9223917 MOUNTING SYSTEM: ZEP Miahty Hook (72) KYOCERA # KU2656ZPA INVERTER FRONIUS # Primo 8.2 00 POISE OW1 - STARKWEATHER, JIM 52380 SILVER STAR TRAIL LA QUINTA, CA 92253 (760) 217-3333 DESCRIPTION: STARKWEATHER RESIDENCE 19.08 KW PV ARRAY PAGE NAME SITE PLAN PITCH: 18 ARRAY PITCH: 18 MPI AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Spanish Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Spanish Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP3 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Spanish Tile STORY: 2 Stories I FC;FNn (E) UTILITY METER & WARNING LABEL lay INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS P.61 CONFIDENTIAL - THE INFORMATION HEREIN WI- A6;, CONTAINED SHALL NOT BE USED FOR THE • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., S NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ODEDICATED ORGANIZATION, EXCEPT IN CONNECTION WITH Q SALE AND USE OF THE RESPECTIVE ItoTHE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN a PERMISSION OF SOLARCITY INC. — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 1� INTERIOR EQUIPMENT IS DASHED ,IOB NUMBER JB -9223917 MOUNTING SYSTEM: ZEP Miahty Hook (72) KYOCERA # KU2656ZPA INVERTER FRONIUS # Primo 8.2 00 POISE OW1 - STARKWEATHER, JIM 52380 SILVER STAR TRAIL LA QUINTA, CA 92253 (760) 217-3333 DESCRIPTION: STARKWEATHER RESIDENCE 19.08 KW PV ARRAY PAGE NAME SITE PLAN PITCH: 18 ARRAY PITCH: 18 MPI AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Spanish Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Spanish Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP3 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Spanish Tile STORY: 2 Stories I FC;FNn (E) UTILITY METER & WARNING LABEL lay INVERTER W/ INTEGRATED DC DISCO SITE PLAN Scale: 3/32" = 1' 01, 10' 21' SHEET: REV: DATE PV 2 7/8/2015 N W E S SolarCity. 3055 aearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-aTY (765-2489) www.solarcitycom & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS DQ DISTRIBUTION PANEL & LABELS LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 1% e I INTERIOR EQUIPMENT IS DASHED L _'J SITE PLAN Scale: 3/32" = 1' 01, 10' 21' SHEET: REV: DATE PV 2 7/8/2015 N W E S SolarCity. 3055 aearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-aTY (765-2489) www.solarcitycom I I A SIDE VIEW OF MPI . NTs MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 52" 52" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 90 PITCH 18 STORIES: 2 PART TO OTHERS OUTSIDE THE RECIPIENT'S ARRAY AZI 90 PITCH 18 BOT CHORD 2x4 @24" OC THESALE AND USE OF THE RESPECTIVE S -Tile (Cement) SIDE VIEW OF MP3 NTS MP3. X -SPACING X -CANTILEVER -Y-SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 52" 52" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC • BOT CHORD 2x4 @24" OC ROOF AZI ARRAY AZI 270 PITCH 18 STORIES: 2 270 PITCH 18 S -Tile (Cement) _ B SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y-CAN11LEVER NOTES LANDSCAPE 72" 24" 52" 24" PORTRAIT 1 48" 20" 52" 24" TOP CHORD 2X4 @ 24" OC ROOF AZI 180 PITCH 18 STORIES: 2 ARRAY AZI 180 PITCH 18 BOT CHORD 2x4 @24" OC S -Tile (Cement) INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER • DIA BOLT & NUTCLEAN PAPER AROUND PILOT (1) (2) (7) (3) 2) HOLE. ZEP'SPANNER BAR CLAMP 3) ADJUST STANDOFF TO. BATTEN - - STANDOFF HEIGHT. (E) TILE SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE . (E) ROOF DECKING (5) (4) CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9223917 �' CONTAINED SHALL NOT BE USED FOR THE 5) BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSIEIA NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENT'S (2-1/2" EMBED, MIN) ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES:- ODULESTHE THESALE AND USE OF THE RESPECTIVE (72) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. FRONIUS PFimD 8.2 _ B SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y-CAN11LEVER NOTES LANDSCAPE 72" 24" 52" 24" PORTRAIT 1 48" 20" 52" 24" TOP CHORD 2X4 @ 24" OC ROOF AZI 180 PITCH 18 STORIES: 2 ARRAY AZI 180 PITCH 18 BOT CHORD 2x4 @24" OC S -Tile (Cement) INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER • DIA BOLT & NUTCLEAN PAPER AROUND PILOT (1) (2) (7) (3) 2) HOLE. ZEP'SPANNER BAR CLAMP 3) ADJUST STANDOFF TO. BATTEN - - STANDOFF HEIGHT. (E) TILE SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE . (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA STAINLESS 5) LAG STANDOFF INTO RAFTER. STEEL LAG BOLT (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES 6) NOTCH TILE WEATHERING TO FIT • (E) RAFTER - STANDOFF i Scale' 1 1/2" = 1' 7) AROUND STANDOFF. REINSTALL TILE. STARKWEATHER, JIM 52380 SILVER STAR TRAIL - LA QUINTA, CA 92253 (760) 21.7-3333 DE MPTION: (7i STARKWEATHER RESIDENCE TO nV 19.08 KW PV ARRAY - SolalrCitv 3055 Cleamler Way PAGE NAME' REV. DATE Son Mateo, CA 9002, T:(650) 638-1028 F:(650) 638-1029 STRUCTURAL VIEWS - PV 3 7/8/2015 (666)—SOL—CITY (765-2489) www.solarcitYcom 2" MAX 2" MIN CLEAR SPAN DIAMETERTO UNDERSIDE VENT SPANNING DETAIL OF MODULE NTS 6" MIN. VENT HEIGHT FROM TOP SOLAR PANEL %' OF ROOFIfJG MATERIAL i SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD VENT PIPE (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 2013 CPC 310.5 STATES 'NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = TT*R' WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE = (7r*D)*D = (7r*2*R)*(2*R) = 4*Tr*R2 4*7T*R2 > 1T*RZ FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -9223917 0 0 PREMISE DWNER CONTAINED SHALL NOT BE USED FOR THE STARKWEATHER, JIM BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 52380 SILVER STAR TRAIL PART TO OTHERS OUTSIDE THE RECIPIENTS MoouEs LA QUINTA, CA 92253 TTHHE�SALEEnAND USES OF IN NHE RESPECTIIVE�TM (72) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WTHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 760 217-3333 FRONIUS # Primo 8.2 UPLIFT CALCULATIONS 07.08.2015 PV SVersion #46.4 ystem Structural - So larCity. Desion Software Project Information & Table Of Contents Ric Category: - - - PV System Type _ _ _ SolarCity SleekMount'TM Spanish Tile Roof Spanish Tile Roof Layers of tornp Roofi Roof _Slope Rafter 5 an - 24 O.C. Orienttion PV System Module a _ _ Landscape and Portrait - - — -- . PV Module Area 1275 sf PV Module Width 39" PV Module Length _65" Standoff Attachment Hardware Mighty Hook HOG ST Reduced Ground/Roof Live Snow Loads _ Ground Snow Load ._- - -- _ -pg, -_- _ . _-- _-- 0.0 psf _ _ ASCE Table 7-1 -_ Surrounding Roof Snow -- _ -- _-- _. 0.0 psf __ _ _-_- __- ASCE 7.4-1 Roof Snow Over PV Modules 0.0 ASCE E . 7.4-1 Wind Design Criteria - -- Wind Design Code -__ _ ASCE 7-10 Wind Design Method _ - - -- _ Partially/WIIYEndosed Method - _ Basic Wind -Speed V _----- -110 mph -_-_ -__- Fig.,265-3A Exposure_Cate gory C Section 263 Roof Style Gable Roof Fig 30.42A/B/C 5A/B r _ - Mean Roof Height 25 ft - _ Section 26.2____ Effective Wind Area 1 Module A 17.7 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz _ _ _ - _ 0.95- Table 30.3-1 Topographic Factor 1.00 Section 26.8 _ Wind Directionality Factor Kd _- 0_85 _ - _Section 26.6-1- Importance Factor I _ NA - -- Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 24.9 psf Ext. PressureCoefficient(Up)_____. G__Cp (Up)._ -0.88 - --- - - - - - -0.45 Fig. 30.42A/B/C SA/B Ext. Pressure Coeffident Down Down Fig. 30A-2A/I3/C-5A/B Design Wind Pressure P p= h GG Equation 30.4-1 Wind. Pressure-t)P ---- --___PLOP)-------- -21.8-Psf-- ------ ---- — Wind Pressure Down down 16.0 psf Allowable Standoff Soadngs X -Direction Y -Direction`, Max Allowable Standoff Sparing - Landscape 72" -- - 52' Max Nlowable Cantilever_ _ _. Standoff Confiuration _andscape Landscape Not -§!a ered Max Standoff Tributary Area_______- _ _--__Trib _ - _--_-_- -_-__ _ ---__26 sf - - — PV Assembly Dead Loaq VV -PV _ _ 3 psf - Net Wind Uplift_at Standoff_ _ _ _ - _Tactual. _ _ _ _ -- _ -295 lbs - Uplift Capacity of Standoff T -allow 350 lbs Standoff Dernand/Capacitv DCR 84.4% Max Allowable Standoff Spa _-_Portrait _ 48' S2" Max Allowable Cantilever-.--_____ Portrait _ 20' ___ _ _-_24" -_• Standoff Confi uration Portrait Not -Staggered Max Standoff_ Tributary Area - -_ - -_Tnb PV Assembly Dead Load - -.- W -PV _- __-- - —_ 3 psf Net Wind Uplift at Standoff _ T -actual _ . - --197 lbs Uplift_Capacity-ofStandoff T -allow__-. 350 lbs -_ Standoff Demand Ca . t=_ 56.29'o STARKWEATHER RESIDENCE 19.08 KW PV ARRAY PAGE NAME. UPLIFT CALCULATIONS r n%I N1 SHEET: REV.. DAIS PV 4 7/8/2015 SolarCity. 1 3055 Cleaniew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (868)-SOL-CrTY (765-2489) ww.solorcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) LIFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 -(I)FRONIUSLABEL inve a n820OW pAntenna - (12)KYOCERA #KU2656ZPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number:1B45R-102642 Inv 2: DC Ungrounded 240V, w PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, o Backbar C-10 Underground Service Entrance INV 2 -(1)FRONIUS$ Primo 8.2 LABEL B AFCI Inve er, 820OW, 240V, 97%, w/ Antenna Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 225A MAIN SERVICE PANEL �N N3 175A/2P MAIN CIRCUIT BREAKER ' Inverter 1 IND B, CUTLER -HAMMER LoadYANT 7 (N) 1�5A Lead Cantor- 1 1 /5A/2N Ulsi onnel t 5 FRONIUS DC+ 13 Primo 8.2 DC- MP3: tpj (E) LOADS q �' 50A/2P �\ _ " r _ EGC _ - - z -1x10 - - _ • DG+ I G+ DC - 9 90A/2P N DC I C_ c- MP1:1x13 I • - - - - GND 13 jAf _ _ , .- n------------------------- EGG Dc+ - ceC ---i NGND MP2: 1x13II,-JIlw_ 1 I Z 1 __ EGC- -- GC I .J (1) CQIJDUIT KIT Inverter 2 IND 1 x 10' EMT Conduit N 1 1 - EGGGEC _ o--- --- 1 I 1 6 FRONIUS Primo 8.2 3 Dc+ oc- MPI.: cec 50A/2P I u z4ov r-------- _ EGC _ - - -1x12 - - -TO ----� SINGLE PHASE 1 1 1 L - ---------------------------- _ DG+ � N DC- I EGC! DC+ —GEC ---TN DC+ C_ c- MP1: 1x12 1 UTILITY SERVICE 1 DC- C- MP2: 1x12 • GC . 1 1 (1)CQj1DUIT,KIT I � STRINGS ARE COMBINED AT THE INVERTER 1 x 10 EMT Conduit CITYOF LA QUINTA PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED BUILDING & SAFETY DEPT. AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, APPROVED TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF FOR CONSTRUCTION GROUPING SHALL.BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL BY ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS Voc* = MAX VOC AT MIN TEMP POI 0 )Ground Rod; 5/8' x 8', Copper A (1)CUTLER-HAMMER ® DC323URB n Disconnect; 10OX 24OVoc, Non -Fusible, NEMA 3R ®� /•1 - (1) GER D0�00at%61A General Duty (DG) B (1) BLoYad Centerr 125A,R120/24OV, NEMA 3R - (2)CUTLER-HAMM 8 BR250 Breaker, 50A 2P, 2 Spaces , (1)AWG 13, THWN-2, Blade O (1)AWG 83, THWN-2, Red O �' (I)AWG 88, THWN-2, Black Iql- (1)AWG #8, THWN-2, Red 2)AWG 810, PV Wire, 60OV, Blade Voc* = 431.26 VDC- Isc = 9.26 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp = 310 VDC Imp= 8.55 ADC (1)AWG 13, THWN-2, White NEUTRAL Vmp =240 VAC Imp=68.4 AAC 70 AWP /6,• 1HWN-2,. Green EGC/GTP- (1)CQ�JDUIT KIT 1 z'10' EMT ColiduR ' ' (1)AWG 810, THWN-2, White 70 AWG 86,. TFtWN-2,• Green • .EGC/GEC (1 AWG 8g THWN-4 Blade NEUTRAL Vmp =240 VAC Imp=34.2 AAC .- (1)Conduit. Kit:_ 3/4'.EM7.... • .. • • • . _ • • • • • • .. (1 Conduit Kit; 3/4' EMT (4 AWG 810, PV Wire, 60OV, Blade Voc* = 560.64VDC Isc = 9.26 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp = 403 VDC Imp= 8.55 ADC OD( (1) AWG 88 , THWN-2, Red rt 1 Conduit Kit; 3 4 EMT (1 )AWG 810, THWN-2, White 70 )AWG 86,. TH.WN72,. Green NEUTRAL Vmp =240 VAC Imp=34.2 AAC EGC/GEC.- (1)Conduit• Kit;. 3/4'.EMT...... (2 AWG 810, PV•B1re, 600V, Blade Voc 517.51 VDC Isc -9.26 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp =372 VDC Imp= 8.55 ADC • • • • • • • _ . • • (1 Conduit Kit; 3/4'. EMT. • • • • • (4)AWG #10, PV Wire, 60OV, Black Voc* = 517.51 VDC Isc = 9.26 ADC ®Iczl- (1)AWG 810, Solid Bare Copper EGC Vmp = 372 VDC Imp= 8.55 ADC i (1)rmdtjif Kit. 3/4* FM7 CONFIDENTIAL. - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED fOR THE JOB NUMBER JB -9223917 O O PREMISE OWNER: STARKWEATHER, JIM DESCRIPTION: TO BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 52380 SILVER STAR TRAIL STARKWEATHER RESIDENCE i FI6 SOh��I y.' MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 19.08 KW PV ARRAY PART IZ OTHERSTHE RECIPIENT'S ORGANIZATION, EXCEPT IN IN CONNECTION WITH LA QUINTA CA 92253 r ' MODULES 3055 aearvlew Way Son.Mae CA 94402 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN (72) KYOCERA # KU2656ZPA PAGE NAME SHEET: REV. DATE: INVERTER: FRONIUS # Primo 8.2 PERMISSION OF SOLARCITY INC. (760) 217-3333 THREE LINE DIAGRAM PV 5 7/8/2015 T. (650) ) 638-1029 (BBB)-SOL-aTY (765-2489) www.solaTcitycom EXISTING ELECTRICAL SERVICE ENTRANCE AND LOAD CENTER 225A 240V 10 175A MAIN BREAKER 90A/2P TO 120/240V SINGLE PHASE ITILITY SERVICE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER HAMMER # DG323URB 100A, 240VAC ELECTRICAL ONE LINE DIAGRAM AC COMBINER PANEL BRYANT # BR481-125RP LOAD CENTER; 125A 120/24OV, NEMA 3R 5OA/2P 50A AC gEf 8200 WATT UTILITY INTERACTIVE INVERTER 230 TO 600 VDC TO 120 /240 VAC 10 FRONIUS PRIMO 8.2 10 MODULES 2600 WATT PHOTOVOLTAIC ARRAY #3 26 MODULES 6760 WATT PHOTOVOLTAIC ARRAY #1 & 2 XDC 12 MODULES 3120 WATT PHOTOVOLTAIC ARRAY #1 8200 WATT UTILITY INTERACTIVE INVERTER (41 24 MODULES 230 TO 600 VDC TO 120 /240 VAC 10 6240 WATT i FRONIUS PRIMO 8.2 PHOTOVOLTAIC ARRAY #1 & 2 7 (3) AWG #3, THWN-2 (1 ) AWG #10, THWN-2, Green, EGC • Vmp = 240 VAC • Imp = 68.4 AAC 5 (2) AWG #8, THWN-2 (1) AWG #10, THWN-2 ( 1 ) AWG #6, THWN-2, Green, EGG -• Vmp = 240 VAC • Imp = 34.2 AAC (2 ) AWG #8, THWN-2 (1) AWG #10, THWN-2 (1 ) AWG #6, THWN-2, Green, EGC • Vmp = 240 VAC • Imp = 34.2 AAC vL (2) AWG #10, USE-2/RHW-2, Black DE ( 1 ) AWG #10, Solid Bare Copper EGG vL (4) AWG #10, USE-2/RHW-2, Black ' (1) AWG #10, Solid Bare Copper EGG ( (2) AWG #10, USE-2/RHW-2, Black vL (1) AWG #10, Solid Bare Copper EGC A —(4)AWG (4)AWG #10, USE-2/RHW-2, Black '� (1) AWG #10, Solid Bare Copper EGC CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE 108 NUMBER JB -9223917 00 PREMISE OWNER: uwuarnun: STARKWEATHER, JIM STARKWEATHER RESIDENCE �-- kain� SolarCity.NOR M0°"'�"G SYM: OF ANYONE T CIN 52380 SILVER STAR TRAIL 19.08 KW PV ARRAY INWHWHOLE ORCITY SHALL ITT BE DISCLOSEDEFIT ght ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 MODULES: 3055 Clearvier Way SHEET: REV: DATE THE SALE AND USE OF THE RESPECTIVE (72) KYOCERA # KU2656ZPA PAGE NAME San Mateo, CA 94402 T 638-1029 638-105 F:9) INVERTER: FRONIUS Primo 8.2 QUI MENT,IWI INOUT THE WRITTEN PSOLARCITY ERMISIONEQUIPMENT, OF C 7VO 217-3333 ONE LINE DIAGRAM PV 6 7/8/2015 -SOL w (W)—SOL—CITY cies-24B9) ,r.�.Salarany. ELECTRICAL CALCULATIONS Module: 36 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Inverter 1: 1 Fronius Primo 8.2-1 Gen 2 0.96 8200 8271.59 Vdrop = Im 2 * Len th * Resistance / mp) 36 Kyocera 265W 1000V 238.1 Module: Im A Max. Length ft Wire 1 Fronius Primo 8.2-1 Gen 2 _� 0.96 8200 8271.59 Inverter 2: String- 8.55 80 AWG #10 at Max Ave Hi: 109 deg F Module: Vdrop = 8.55 160 0.00124 Ohms / 313.41 0.54 Branch: 8.55 50 AWG #10 at Max Ave Hi: 109 deg F Vdrop = (8.55 100 0.00124 Ohms) / 372 0.34 Volta a dro in DC conductors = 0.88 InvertPr: 34,? 1 n AWC #8 dl 240V Kyocera 265W 1000V 238.1 Inverter 3: Module: Kyocera 265W 1000V 238.1 Inverter 4: ��PATotal t ' Total: 72 Modules Total Inv Pwc 16400 116543.191 PTC Vdrop = 34.2 20 Combinedi 54.72 1 15 0.00078 Ohms/ 240 V 0.06 1 AWG #3 1 at 240V Photovoltaic Module Electrical Specifications: Total STC:I 19080 Vdrop = 54.72 30 0.00024 Ohms) / 240 V 0.05 Voc: 38.3 V deg F deg C Vmp: 31 V Record Low Temp: 14 -10 Total voltage drop in AC conductors = 0.11 Isc: 9.26 A Max Average Hi Temp: 109 43 Total voltage drop in AC and DC conductors = x Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisa 5.56 mA/deg C String Type A and 2 Combined Strings Type A v Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 13 modules per series string " . t - Fronius Primo 8.2-1 Gen 2 12 Kyocera 265W 1000V Voc= 459.6 Vmp= 372 Isc= 9.26Isc= Imp= 8.55 (cont= 11.58 Art 690.8(A)(1) Voc Correction Factor: Inverter Inverter Min Vdc Input: Min Vmp at Max Temp: Max Voc at Min Temp: Inverter Max Vdc Input: Max String Size: 1 -way wire length: strings per branch Voc= 497.9 V Vmp= 403 V 18.52 A Imp= 17.1 A lcont=1 28.94 A 1 way wire length: Art690.8(A)(1) N/A 130 313.41 517.51 600 13 50 1.a Try AWG #10 USE-2/RHW-2 at 90 deg C: Table 310.16 3.a Try N/A Icont * 1.25 = (Amps) 36.17 Icont * 1.25 = (Amps) 14.47 30 deg C ampacity = N/A 3.b Icont-- (Amps) Start ampacity 28.94 ^ CITY OF 1--A-Q1 11 30 deg C ampacity = - 40 1.b Icont= (Amps) 11.58 N/A N/A BUILDING & SR►FETY DEPT. Am P 0-® E D Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) 40 0.41 1 Temperature derate (%=F) Conduit fill derate (%--#) Derated ampacity N/A N/A 3.c Term 1 Term 2 CONSTRUCTION Derated ampacity 16.4 FOR -Temp table N/A N/A 1.c /�� (cont * 1.25 = (Amps) 14.47 (cont*1.25= (Amps) 36.17 14.47 DATE 3 BY �! Ampacity - 40 Ampacity N/A N/A 2 Icont * 1.25 = (Amps) 14.47 3.d OCP Size 1 40 OCP Size = 15 Combined Inverter Output ' Inverter Type A Output Fronius Primo 8.2-1 Gen 2 Icont = 34.2 1 A Y way wire)ength: 10 ft Art 690.8(A)(1) Service Voltage= Total Inverter Power- = # of inverters*max inverter Icont = (Amps) 1 way wire length= current Art 690.8(A)(1) 15Icont 4 Icont * 1.25 = (Amps) ' 42.75 Art 690.8(B)(1) 6 (cont*1.25 = (Amps) 85.5 Art 690.8(B)(1) 45 90 OCP Size = Art 240.6(A) OCP size = Art 240.6(A) 5.a Try I AWG #8 THWN-2 at 90 deg C: Table 310.16 7.a Try, AWG #3 THWN-2 at 90 deg C: Table 310.16 Icont * 1.25 = (Amps) 42.75 Icont * 1.25 = (Amps) 85.5 30 deg C ampacity = 7 55 30 deg C ampacity = 115 5.b Icont = (Amps) 34.2 7.b Icont = (Amps) 68.4 55 115 Start ampacity _' Siarfampacity•--• . 0.91 0.91 " - - - Temperature derate (%=F) Conduit fill derate (%_#) Temperature derate (%=F) Conduit fill derate (%=#) 1 1 Derated ampacity 50.05 Derated ampacity 104.65 5.c Icont * 1.25 = (Amps) 42.75 7.c Icont * 1.25 = (Amps) 85.5 Ampacity 50 Ampacity 100 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF ANYONE EXCEPT SOLARCITY INC.,MOUNTING NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS EXCEPT IN THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE , THE RESPECTIVE SOLARg1Y EQUIPMENTT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITYINC. JOB NUMBER J B- 9 2 2 3 917 0 O PREMISE OWNER., STARKWEATHER, JIM 52380 SILVER STAR TRAIL LA QUINTA CA 92253 � (760) 217-3333 DESCRIPTION: STARKWEATHER RESIDENCEBENEFIT 19.08 KW PV ARRAY, PAGE NAME ELECTRICAL CALCULATIONS - k-rll � SYSTEM:SolarCity ZEP Mighty Hook MODULES: (72) KYOCERA # KU2656ZPA . 3055 gearview Way TT. -(650) Son 638-1028, CA 94) 638-1029 (888) -SOL -CITY (765-2489) www.edarcity.com SHS' REV: DATE: PV 7 .,7/8/2015 INVERTER: FRONIUS # Primo 8.2 ELECTRICAL CALCULATIONS CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. nel Load Breaker I VA SPA 50A/2P 31500 Oven 50A/2P )i hwasher/Garbage Disposal 15A/2P 1500 Air Conditioner 100A/2P Laundry 20A/1P Bathroom 20A/1P Lighting Circuit 15A/1P Lighting Circuit 15A/1P Lighting Circuit 15A/IP Lighting Circuit 15A/1P Lighting Circuit 15A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P Small Appliance 20A/1P CITY OF L` QLJIDEPT. gUILDING & S®� APp FOR CONSTRUCTION D11EV/6 BY �- JOB NUMBM JB -9223917 00 MOUNTING SYSTEM: ZEP Mighty Hook MODULES:- (72) ODULES(72) KYOCERA # KU2656ZPA INVERTER FRONIUS # Primo 8.2 STARKWEATHER, JIM 52380 SILVER STAR TRAIL LA QUINTA, CA 92253 (760) 217-3333 3.0 NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service ... is of sufficient capacity ... The following percentages shall be used for existing loads ... First 8 kVA of load at 100°/x, Remainder of load at 40% NEC 220.83(6)(1) General lighting and general -use receptacles at ... 3 volt-amperes/ft2 as determined by 220.12. Floor Area (3VA/sq ft) I Ft I VA 29051 8715 NEC 220.83(6)(2) 1500 VA for each 2 -wire, 20 -ampere small -appliance branch circuit and each laiindry hranrh circuit covered in 210.11(C)(1) and (C)(2). NEC 220.83(6)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... rnnrtl %Aintar haatarc" Qty I VA Small Appliance Circuits 21 31500 Laundry Circuits 1 1500 Bathroom Circuits 1 1500 NEC 220.83(6)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... rnnrtl %Aintar haatarc" Total General Load (non -A/C load) 65295 VA First 8 kVA of load at 100% 8000 General Calculated Load (non -A/C load) 30918 VA NEC 220.83(B) The larger connected load of air-conditioning or space -heating, but not both, chnll ha near] rat] inn Parrant of I nnrt Breakerl VA SPA 50 9600 Oven 50 9600 Dishwasher/Garbage Disposal 15 2880 Total General Load (non -A/C load) 65295 VA First 8 kVA of load at 100% 8000 General Calculated Load (non -A/C load) 30918 VA NEC 220.83(B) The larger connected load of air-conditioning or space -heating, but not both, chnll ha near] rat] inn Parrant of I nnrt Max Heating and Air -Conditioning load 18000 VA Total Load Sum of General Calculated Load 48918 VA & Heating and A/C Load 203.83 A DESCRIPTION: STARKWEATHER RESIDENCE 19.08 KW PV ARRAY PAGE NAME ELECTRICAL LOAD CALCULATIONS SHEET: REV: DATE- PV ATEPV 8 7/8/2015 SolarCity.' — 1 3055 CleaMew Way Sm Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com Breaker VA Sum of A/C Equipment Sum of Electric Furnaces 100 0 18000 0 Max Heating and Air -Conditioning load 18000 VA Total Load Sum of General Calculated Load 48918 VA & Heating and A/C Load 203.83 A DESCRIPTION: STARKWEATHER RESIDENCE 19.08 KW PV ARRAY PAGE NAME ELECTRICAL LOAD CALCULATIONS SHEET: REV: DATE- PV ATEPV 8 7/8/2015 SolarCity.' — 1 3055 CleaMew Way Sm Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com CAUTI:0N._' POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 52380 Silver Star Trail . AC .., DISCONNECT - - - - -- r,--, UTILITY > SERVICE Ll 'L� . I I I I , rj 'L__j INVERTER AND r - DC DISCONNECT • INVERTER AND DC DISCONNECT r-------------------- ------� SOLAR PHOTOVOLTAIC ARRAY(S) L--------------------------- J PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL.. IS AN A/C DISCONNECT PER NEC 690.17 r OPERATING VOLTAGE = 240V JB -9223917-00 ' 4 .1 CAUTI:0N._' POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 52380 Silver Star Trail . AC .., DISCONNECT - - - - -- r,--, UTILITY > SERVICE Ll 'L� . I I I I , rj 'L__j INVERTER AND r - DC DISCONNECT • INVERTER AND DC DISCONNECT r-------------------- ------� SOLAR PHOTOVOLTAIC ARRAY(S) L--------------------------- J PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL.. IS AN A/C DISCONNECT PER NEC 690.17 r OPERATING VOLTAGE = 240V JB -9223917-00 - 1. • _ _ .1 ., . • • - _ t i n • - CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SMALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBERJB-9223917 0 0 PREMISE OWNER: STARKWEATHER, JIM DESCRIPTION: STARKWEATHER RESIDENCE, Solar, "It MOUNTING SYSTEM:, NOR MALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook , 52380_ SILVER STAR TRAIL 19.08 - KW PV •ARRAY ; ,: " 'PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION WITH , MODULES: LA QUINTI CA 922533 ^3055 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN (72) KYOCERA . # KU2656ZPA PAGE NAME Cleorview Way E San Moteo_CA 94402 SHEET: REV DATE PERMISSION OF SOLARCITYANC. ERTER: ` �: INVERTER FRONIUS' Primo 8.2 (•760). 217-3333 -SITE PLAN PLACARD - PV 9 _ 7/8/2015 - - T.-(650) 638-1028 F:(650) 638-1029 , (89) -SOL -CITY (765-2489) !".sdarcRy,can Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED IQUI® �-, OF LA sUIL®IvG & sDEPT. FOR CONSTRUCTION DATE ✓ r� BY (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `���i�!� 3055 Geaview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �' �" ��O' F 9aaoz 29 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, ��` T:(650) 638-1028 (765-2 89) w) .solar it EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Label Set /� Sola 't(888}SOL{ITY(765-2489)www.solarary.can SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. in/,Perfect Welding/ Solar Energy / Perfect Charging r i ; Sy RIFTING THE LIMITS ' FRONIUS�PRIMO' / The future of residential solar is here - Introducing the new Fronius Prima t` r t� s� 4norr�w / With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation and service. / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors. Other standard features include a Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. TECHNICAL DATA FRONIUS PRIMO GENERAL DATA STANDARD WITH ALL PRIMO MODELS Dimensions (width x height x depth) t - 16.9 x 24.7 x 8.1 in. M iY[•I1�r... _ -_- - __ -_ v„ - - _ . 472916 Degree of protection l NEMA 4X Night ttmcconsuet tion 1 W Inverter topology - P Transfonncdcss oolin 71171111, spMm fan Insmllaion t-+ - Indoor and outdoor installation .Ambient. ,cia0n tem ermure rem c �t0 _. 31F 40 .. 5S'C Pcrmined humidify J 0.100% UC en ection Icrminaly11 9 DC+end 4x i - rm t retinals for coaptrjs.lid t shandccl fin-arandedl a aluminum slid strandM ACconnecl'o n ierminals I Screw terminals 12.6 AWG - - CntiEcau- and roetpliance with standards _ UL 1741•"1070, UL799 (for functions: AFCI and isolation n taring, IEEE 1547-2011,111111411-11 .03, ANSI/IEEE C62A1, FCC fart 15 A & R. N.EC Art d 690. C22.2 N. 107.1.01 iS ptc nbet20011 UL169981ssu� 2 201?, CSA Ttl. M 071ssuc PROTECTIVE DEVICES STANDARD WITH ALL PRIMO MODELS AFCI & 2014 NEC Ready I Yes Ground Fauh Protccnon with IxtL tion Monitor hur-rue, 1L•s DCdisconnm - Yes _ UC rcvcrsq polarity protection YCs INTERFACES STANDARD WITH ALL PRIMO MODELS Wi-W/Ethernet/Serial - I Wirelms standard 802.11 b/g/n / Fronius Solacweb, SunSpec Modbus TCF; ISON / SunSpec Modbus RTU 6 Inputs or 4 digital inputs outputs 51 Evermd relay controls USH (A socket) I Datalogging and/or updating via USN 12. RS412 (R145 sed.et) Fronius Solar Net inion..: protocol LDataloggerand Webserver f I Included 1 ,The lean Wi-FiQ is a registered trader -1,.11a Wi.Fi Allionce. TECHNICAL DATA FRONIUS PRIMO 101111111111111111 INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Rc[ommcndcd PV power(kWp) ( 3.0-6.0 kW 4.0-7.8 kW I 4.8-9.3 kW f 6.1-11.7kW ••. 6.6-12.7 kW Max, usoblc In tut current mPpT 7 N PPT 2 18 A 118 A 11 18 A 18 A If 18A/18A 18 A 18 A 18 A I A Total max. DC current ( 8200 W 36 A 208, 18.3 A Max, arW, short circuit current I 28.8 A - 36.5 A 2x'22.5 A 24611 Operating voltage range -1 25.0 A 80 V* - 600 V 34.2 A Recommended OCPI7/AC breaker sizc Max..I,putvoltmc • 25 A I 30 A 600y � - 50 A 50 A Nominal input voltage 410V ( 420 V420 t V 420 V I 420 V Admissable conductor size DC �. Max. IifOciency AWG 14... AWG 6 ' 96.9% I. 96.9% �.. MPP Voltage Range _ 200-480V 240-480V ) _ -240-480V 250-480V 270-480V Number of MPPT 96.U'SF _96.5906 2 ' Stoning with serial number 26170960; before serial number: 150 V OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 IF PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Max. output power 208,1 3800 W 5000 W • ' 6000 W I 7600 W I 7900 W ^4 3800 W 000 W 6000 W 7600 W 8200 W M.x. continuous output current 208, 18.3 A 24.0 A I 28.8 A - 36.5 A I 38.0 A M 24611 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A Recommended OCPI7/AC breaker sizc 208! • 25 A I 30 A I 40 A � - 50 A 50 A 24dI 20A_ 11 30A 11 35 A 11 40A 1145 A �. Max. IifOciency 96.7 % ' 96.9% I. 96.9% I 96.9% . - I 97.0% CEC f:8iclenr 290 95.0 96 45.5 70 96.[1 `fo 96.U'SF _96.5906 AdmissobI= nduct., size AC - AWG 14 - AWG 6 Crid conrrrtiwt 208/,240 Frequency I 60 Hz ' - T.W harmonic distortion .5.0% Tower L•,cmr (cos Ty.,,) 0.85-1 ind/cap A p/ Perfect Welding / Solar Energy/ Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF OSSIBILITY. / Whether welding technology, photovoltaics or battery charging technology - our goal is clearly defined:: 6 be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible - our record of over 1,000 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use Jour resources forms the basis of our corporate policy. Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.conn - - Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA Rev. 5.20.15 USA -- - pv-support-usa®fronius.com www.fronius-usa.com "$oiarCity ®pSolar Next -Level PV Mounting Technology '- Soiaririty I ®pSolar Next -Level PV Mounting Technology Components ZS Span for concrete tile roofs 1x 3x U Spanner Bar Cam Foot sfO°"e Part Nos. 850-1400-4x 0 580-1399 - 3x _n 850-1398 1x II• -Ground Zap `t .svannerBar L7 j - spannergernp � ry - T4Aok ArraySklrt �.. _. Splice Kit Spanner Clamp Part No. 850-1401 Part No. 850-1194 Listed to UL 2703 Listed to UL 2703 1 3 Comer Cap Interlock Adlusiabta Mighty Hook QCot4PAt, a , N / �,� Description PV mounting solution for concrete tile roofs 'F,eO� Works with all Zep Compatible Modules °Mpp Auto bonding UL -listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Mighty Hook V2, HDG Interlock Cam Foot LISTED Specifications Part No. 850-1461 Part No. 850-1388 Part No. 850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 • Designed for pitch roofs Installs in portrait and landscape orientations C' Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" 4 • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 850-0113, 850-1421, Part No. 850-1448 ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM 1, KU -60 1000V Series - • - EP ST CS - � - - - - ELECTRICAL SPECIFICATIONS � • , -..ti �, , (, Mnnl ILE•CHAR.ACT .I 'I . •. • . I+11ty�'..............- H1�K Ai�_lulVUi�Y 4'U µl� uv.,,,,/-5elr. eS0CERa ..... N.V M1.fV... .... .111%f � _ a KU265-6ZPA ' CUTTING EDGE TECHNOLOGY As a pioneer with four decades,of experience in the " development of photovoltaic systems, Kyocera drives the - market as a leading provider of PV products. We c ' demonstrate our Kaizen philosophy, or commitment to continuous improvement,' by setting the industry standard ` in the innovation of.best-in-classsolar energy equipment. _ l e ' QUALITY BUILT'IN _ } — • UV -stabilized, anodized"aluminum frame in black » • Supported by major mounting structure manufacturers - • • Easily accessible grounding points on all four corners,.; ' for fast installation:= • - '" •.Proven junction box technology with 12 AWG PV wire ' •'" ' works with transformerless inverters „ • Amphenol H4-UTX locking plug-in connectors ' provide safe, quick connections 4 ' PROVEN RELIABILITY., - Kyocera `modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average . output of any crystalline module First module manufacturer in the world to pass long- ` " term sequential testing performed by TUV Rheinland ' . ' ' • Only module manufacturer to achieve the rank of ' "Performance Leader" in all six categories of GTM . t c - s r- Research's 2014 PV Module Reliability Scorecard r t- CERTIFICATIONS - • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • • NEC 2008 Compliant, IEC 6121561:730, and ISO 14001 Standard Test Conditions Pms 265 W, VmP 31.0 t :v Imp 8.55 A VOe a. -38.3 t' "r V I. 9.26., A} Nominal Operating Cell / :// IT.. TemperatUre Conditions / f• 45 (NOCT) °C f 191 w_ VmP 27.9 V i d � mP e. a `685, A V. 35.1 V ,. 7.49 ` . s A PTC= ._ v^' — — - 238:1r - _ -- n ='W Temperature Coefficients P_ -0.45 %1°C �Vmn - .. :r- -0.48 ' .. %/°C Imp ` 0.02 %j°C V. Ki 0.36.. %/°c IK 0.06 %j °C Operating Temp '40 to +90 ?,C Systern • • Series Fuse Rating 15 A Maximum Dc System Voltage (UL) - f x 1000V - 1111 Hailstone Impact in (25mm) @ 51 mp (23ms) Cells per module: 60 (6 x 10) .Dimensions. ' 65.43in/38.98in/1.57in length/wid"eight - (1662mm/990mm/40mm) Weight': 45.21bs (20.5kg) _ • , , ; PACKAGING SPECIFICATIONS Modules per pallet, 20 Pallets per 53' container, 36 y Pallet box dimensions: 66in)40ini43in v *' length%widthAeight._ = (1675mm)1005mm)1055mm) - Pallet box weight: 1015lbs (460kg) 1.57• e� •�.' .. �. •+ , .� , •'� POTTED ' r - • -. 4Y JUNCTION' , yy BOKOP65)- a - -CABLE W/ . y5 m$ - ❑ • - / , CONNECTOR I_1 W, t LABEL . - •,. -,� � � ,'s } ; . �•; '..., • •. � . • tet. elo`z 38.98-(990-) '" t ~• . - ✓ Grounding Hole $lotted Mounting Nola , 0.16• (4m0 0.35_.0.47• (9-114. 2 FRAME CROSS SECTION DIAGRAM N. ' • ' MPpt\Ov 'Subject to simulator measurement uncertainty of +1- 3%. - • - - _ - - _ KYOCERA reserves the right to modify these specifications without notice. - C LONG/SNORT SIDE _ a-? •. • - • - ' • WARNING, Read the instruction _ - - _ manual in its enlircty prior [o - _ • _ _ *t } . r • . # - z - - _ . - QhaMLng. installing BOPeraL- - _ - - _ , ... i.. , ,- • .. ., ing Kyocera Solar modules. 040215 a OUR VALUED PARTNER HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC • • SOLA/ . / KYOCERA Solar,800-223-9580 :II • fax www.kyocerasolar.comr. . Y. `_ � `- 'r , ry ' - - t •1 •`}� • •� • •f -. -„ s ' � • • • 1- � 2a - ; ~•^ I ,•• - . Y _ - n .• •'• ••- Switching Devices Q Safety Switches 8.1 T OG321NRB 120/240 Vac General -Duty, Fusible, Single -Throw, continued Q FaTON* Maximum Horsepower Ratings0 NEMA1 NEMA3R f�llgring&tliaesSWO/Idwide" `; Ampere Fuse Type Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number Cartridge Type—Three-Pole, Three -Wire (Three Blades, Three Fuses) -240 Vac 31 _ _ _ _ _ 0 30A- 60 - _ _ _ _ 0 0DG221URB 100 — — — — — O 0 i- caro 200 - - - - General Duty Safety Switch 400 H — — 50-125 — OG326FGK00 DG326FRK00 Interru or a se guridad servicio li- ero 600 H — — 75-200 — G326FGK00 OG375FRK00 Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac 2 Pole Non -Fusible 88roes: b b b 30 H — 1-1/1-3 3-7-1/2 — DG321NGO DG321NRB ties: B Polos sin f us i b 1 es - Gty ' Cant.: p p 60 H — 3-10 7-1/2-15 — DG322NGB OG322NRB jTd, jjd, T e 3R Rainproof REM EN E.U.A. 0'9/18/3012 100 H 7-1R-15 15-30 OG323NG6 DG373NRB p 8691490 200 H — 15 25-60 OG324NGK OG324NRK '4EMA) Tipo 3R a prueba de LI 400 H — — 50-125 — OG325NGK DG325NRK + 600 H — — 75-200 — DG326NGK OG326NRK ' DG322URB 120/240 Vac General -Duty, Non -Fusible, Single -Throw $ Maximum Horsepower Ratings NEMA1 NEMA 3P ? -- _ 2113 12023 2 � Ampere Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof System Rating 120V 240V 240V 250V Catalog Number Catalog Number Two -Pole, Two -Wire (Two Blades) -240 Vac I 30 2 3 — — OG221UGBO DG221URBO 60 3 10 — — OG222UGBr'r OG222URB r't q q 100 — 15 — — OG223UGBO OG223URB0 200 — — — — Three -Pole, Three -Wire (Three Blades) -240 Vac I I I 30 2 3 7-1/2 — OG321UGB0 OG321UROO 60 3 � 00 5 30 — OG323UGB0 OG323URB0 q q q 200 — 15 60 — DG324UGKO OG324URKO 400 — — 125 — DG325UGK0 UG32SURK0 600 — — 200 — OG326UGK0• OG326URK0 Notes O Maximum hp ratings apply only when dual element time delay fuses are used. OUse four -wire catalog numbers below. 0 Solid neutral bars are not included. Order separately from table on Page 15. ar WARNINGI Switch is not approved for service entrance unless a neutral kit is installed. t•t Use three -wire catalog numbers below. O Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory on 20M00A general -duty switches. Catalog Numbers: 200A = 70-7759-11, 400A = 70-8063.8. SODA = 70-8064-8. Volume 2—Commercial Distribution CA08100003E—February2011 www.eaton.com 27 4 D iCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR N N v 27 6.8 DIA. ' 3 M UN ING HOLES N .88 [221 N B NGENTIAL KNOCKOUTS FOR O 1ANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN. MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM ' NEUTRAL #4-#14 COPPER OR ALUMINUM A TM[rwwm ar reroe mnronmmx WARREN SIPE a 1s se CUTLER—HAMMER ; rz/ B_T•�I s x maomt[ ua PRTSBURGH PA. . s xor ro ec �+oouctn. usn. —nrz R a oscaam o�am wn n¢ nw- R. PROHASKA 8/1 9/98 DIMENSION SHEET °rz°g� Y1°Ce • • "'"�' nrz 30 AMP TYPE 3R GENERAL DUTY 95-1445.DWG SS74DGC1 1-2 •°"65 A c 95-1445 1 av 1 2 1 ` L s 4 D iCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR N N v 27 6.8 DIA. ' e iCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR , 3/4 CONDUIT 1/2, 3/4 CONDUIT N 27 6.8 DIA. ' 3 M UN ING HOLES N .88 [221 N B NGENTIAL KNOCKOUTS FOR O 1ANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN. MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS 4 o >i a • •a k d p av: e/teroe - 4 .261: [5.51 KNOCKOUT QUANTITY 1 D 6.89 [175) 5.73 [1451 O C • iCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR , 3/4 CONDUIT 1/2, 3/4 CONDUIT NT1TY 2 QUANTITY 4 27 6.8 DIA. ' 3 M UN ING HOLES N .88 [221 O rn B NGENTIAL KNOCKOUTS FOR '2, 3/4, 1 CONDUIT 1ANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN. MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM ' NEUTRAL #4-#14 COPPER OR ALUMINUM A TM[rwwm ar reroe mnronmmx WARREN SIPE a 1s se CUTLER—HAMMER ; rz/ B_T•�I s x maomt[ ua PRTSBURGH PA. . s xor ro ec �+oouctn. usn. —nrz R a oscaam o�am wn n¢ nw- R. PROHASKA 8/1 9/98 DIMENSION SHEET °rz°g� Y1°Ce • • "'"�' nrz 30 AMP TYPE 3R GENERAL DUTY 95-1445.DWG SS74DGC1 1-2 •°"65 A c 95-1445 1 av 1 2 1 0" ZepSolar ZS Me - for the roofs ZS Tile'" offers the fastest and least expensive way to install PV arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove frame specification. Utilizing quarter -turn, rock -in, and drop-in con- nections, ZS tile eliminates the need for rails and separate grounding hardware while offering a superior aesthetic approach. Key System Benefits Dramatically reduces installation time Eliminated mounting rails and clip hardware Eliminates separate grounding hardware Rapid, top -accessible precision array leveling Ultra -reliable hyper -bonded grounding matrix Ultra-low parts count Enhanced aesthetics Key Technical Features Low system weight Easily enables additional support at array edges for high wind applications Interlock ETL listed to UL 1703 as ground bond means Ground Zep UL and ETL listed to UL 467 as grounding and bonding device Interlock, Leveling Foot, and Ground Zep listed to UL 2703 as PV bonding device Datasheet: ZS Tile Components Datasheet: ZS Tile Interlock ® Ft The Interlock provides north -south and east -west structural and ground bond connections creating a structurally t contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. Leveling Foot t3l.amm] 130.7mm] A125in 121 in —15�7.2m nm ] [39.4mm] 2.251 I.S,S- 111 1 I ot. 3._in 1— (lot .627] 4.00in The Leveling Foot provides a means of attachment between the PV array and the mounting surface or Flashed attachment apparatus and allows for easy array height adjustment (1.25- throw). Array Skirt J „nom 1 Zep Compatible"' ZS Tile mounting hardware is designed for use with Zep The Array skirt facilitates easy front -row installation white providing a clean look at the front of the PV array. Compatible`" PV modules from leading PV module Manufacturers. Ground Zep d'W Visit zepsolar.com for a current list u� of Zep Compatible`" PV modules. 0 �t TheGround Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Our Other Product Families Universal Box Bracket AC/DC Cable Clip Replacement Tile ZS Aero for low -slope & flat roofs .ZS Comp'. for composition shingle roofs .ZS Seam - for standing seam metal roofs The Universal Box bracket allows rapid attachment of Clips into Zep Groove for ultra -fast and easy The Replacement Tile provides a means of flashed .ZS Span electrical boxes to the module frame. management of PV wiring and micro -inverter cables. attachment for ZS Tile installations. for rail -based applications . Array Skirt Cap Set Tools ZS Trap for trapezoidal metal roofs .ZS Wave - for corrugated roofs The Array Skirt Cap Set provides an aesthetic cover for Zep Toot:4 functions. I tool; Flat Tool: For inter -module the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. ,,O"P4r� ��^ Thh doament Foes rat uedte aoV apes ramnryNlep SobTaabmTlu gadTalsau rieec lep Sob`s sde.assmryismm�md in Thesainen Padetl -"W W 4sit npsobuam mr nmrzinlormaTion4hoetpm padu[uaro compaoT. A% w LISTED pradoss.Tlxmdosersko smixs d4wed•OhlepSelu's ptatissas MibtnThesdesptdaotiam selmed low the pxIWm,w1rThem9maa is mkirnnssctk fc oo"Prs`0 ndly4 The selubl0go1epWsryadcu Ip exhom Soedfimdo uesables 1of3usplChom mtkeC.Pokfit 02010-21H2 1MSob1.1K01 Pst.14.591.57E U.S. Page 1 of 2 Pat.itiog.048.U5StnilPg,e tsPeWiTg. LouUsshmFebnup25,2Ue3:11P11 Page 2 of 2