Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-1419 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA,CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:10=000014-19 Property Address: 533.76—VIA'BELLAGIO APN: 772-500-065- - - Application description: DWELLING - SINGLE FAMILY DETACHED, Property Zoning': LOW DENSITY RESIDENTIAL Application valuation: 377848, - AppC lit: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with . . Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License. Cl ss: B License No.: 744091 • • .• Da e: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the ' . following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_ 1 I,.as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for.sale (Sec. .7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon; and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an'owner of .. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - ( ) I am exempt under Sec. , BAP.C. for this reason ' Date: Owner: CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:. Lender's Address: LQPERMIT Owner: ROBERT CAPETZ 42-590 BRIGHTON ST PALM DESERT, CA -92211 VOICE (760) 777-7012- FAX 77-7012FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/31/11 u Contractor: SUN VISTA DEVELOPMENT CO P.O. BOX 1144 MAR 31 2011 LA.QUINTA, CA 92247 (760) 771-4722 q - CITYOFLAQUINTi4 LiC. NO:: 744091 FINANCEDEPT ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for. which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000179-2009 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700of the Labor Cod 11 all f hwnh comply with those provisions. - Date.. f Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL /SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance_ of such permit, or cessation of work for 180 days will subject - permit to cancellation. I certify that I have read this application and state.that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this co my to en upon the above-mentioned prope y fo in coon .poses. e9 � /t ' Tl l`. -^Dat ` Signature (Applicant or Agent): Application Number 10-00001419 ------ Structure Information 4,398SF DWELLING/VB/RES-3/CL A-FR*[ENG] ----- Other struct info . . . .' CODE EDITION 2007/2008 # BEDROOMS - 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 876.00 PATIO SQ FTG 400.00 NUMBER OF UNITS 1.00 IST FLOOR SQUARE FOOTAGE 4398.00 . Permit . . . BUILDING PERMIT Additional. desc . Permit Fee . . . . 1612`.50 Plan Check Fee 1048.13 Issue Date . . . . Valuation . . 377848 Expiration Date 9/26/11 Qty Unit Charge. Per Extension BASE FEE 639.50 278.00 3.5000 THOU BLDG 100,001-500,000 973.00 Permit . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 201.45" Plan Check Fee 50.36. Issue Date" Valuation . . . . 0 Expiration Date 9/26/11 Qty Unit Charge Per Extension BASE FEE 15.00 4398.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 153.93 876.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL -17.52 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . .. GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . 0 Expiration Date 9/26/11 Qty Unit Charge Per Extension ------------------------------------------------------------------------------ BASE FEE 15..00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 186.50. Plan Check Fee 46.63 LQPERMIT .Application Number 10-00001419 Permit MECHANICAL -Issue Date Valuation . . . 0 Expiration -Date 9/26/11 Qty Unit Charge 'Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36•.00 1.00 4.5000 EA MECH VENT INST/.•DUCT ALT 4.50 4.00 16.5000 EA MECH B/C.>3-15HP/>100K-500KBTU 66.00 9:`00 6.5000 EA MECH VENT FAN 58..50 1.00 6.5000 EA MECH EXHAUST HOOD ----------------------------------------------------------------------------- 6.50 , Permit' . . PLUMBING Additional desc . Permit Fee .222.00" Plan Check Fee 55.50 Issue Date . . . ." Valuation 0 Expiration Date ,. 9/26/11 Qty Unit Charge Per Extension , BASE FEE 15.00 25.00 6.0000 .EA'- PLB FIXTURE 150.00 1.00 '15.0000 EA PLB BUILDING.SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 .1.00 9.0000 EA PLB -LAWN SPRINKLER SYSTEM, 9.00 10..00 '.7500 EA PLB GAS PIPE >=5 7.50 1.00 15'0000 EA PLB GAS METER 15.00. ' ----------------------------------------------------------------------------- Special'Notes and Comments 4,398SF DWELLING/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE POOL, SPA, WATER FEATURES, OR BLOCK WALLS. 2'007/2008 CALIFORNIA BUILDING CODES. .March 28., 2011 12:15:12 PM AORTEGA . Other Fees . . . . . . . . .. ART IN PUBLIC PLACES -RES 444.62 BLDG'STDS ADMIN (SB1473) 16.00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER -RES • 995.00 ENERGY REVIEW FEE 104.81 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 :. DIF LIBRARIES "•- RES 355.00 MULTI -SPECIES (MSHCP). FEE 1284.00 DIF PARK MAINT FAC - RES 22.00. DIF PARKS/REC - RES 892.00 LQPERMIT - .. Application Number 10-00001419 ----------------------- Other.Fees ---------------------------------------------- STRONG MOTION (SMI) - RES 37.78' DIF STREET MAINT FAC-RES. 67.00 DIF TRANSPORTATION - RES 19.30. 00 Fee summary Charged Paid Credited Due Permit Fee Total 2237.45 - -- ----- ---------- ---------- .00 .00 2237.45 Plan Check Total 12.0.0.62 750.00 .00 450.62 - Other Fee Total.-,. 6362.21. 00`. 00 6362.21`. Grand Total 9800.28 750.00 .00 9050.'28 LQPERMIT P.O. BOX 1504 (/ n 78-495 CALLE TAMPICO APPLICATION ONLY AdBu ddre 9 v f A Je'1A IDLA OUINTA, CALIFORNIA 92253 Own!e�l VVr% Vt BUILDING: TYPE CONST. OCC. GRP. Mailing -77 % - fbo— 031) s i1t-k y / `��Ilk Ca, Number 99�� \` �1 Ity Zip Tel. Legal Description',�-T3�y `Y'AC.T.2 �.�, � q Z2S3 b� `l � � 122 Contractor �j Project Description Address �•o. O Iffy ity ,w Z`j2?fS� 'ba Tll-y�Z'Z State Lic.L� q City Sq. Ft. /4 3C? Q No. No. Dw. & Classif. -7 4 1 ` Lic. # Size —1 U Stories Units Arch., Engr.b �1 New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer "ri Address Tel. 12(01 N • $t s el City L��t#-3z6� LICENSED CONTRACTOR'S DECLARATION I hereby aff' m th t I am licensed under rovisions of Chapter 9 (commencing with Section 7000) of Div' ion 3 f th essions Code, and my license is in full for and effect. V SIGNATURE I I DATE OWNER -BUILDER DECLARATI I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own emplo eas, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company 0 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. V S Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure ZuluTOTAL CITY OF GU1N7A REMARKS I FINK ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coacliefla Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DF.VF.T.nPF.R FF.F.S PATT) AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: RECEIPT: 'CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hid�eaw Date: March 31, 2011 Owner's Name: Robert Capetz Phone No. 760-771-4722 Project Address: 53-376 Via Bellagio, LaQuinta, CA Project Description: Single Family Dwelling APN: 777-160-030 Tract #: Lot #'s: Type of Development: Residential XX, Commercial Industrial Total Square Feet of Building Area: 4,398 sq. ft. Certification of Appticant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: March 31, 2011 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN. ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq.Ft. 4398 Amount per Sq.Ft. $2.97 Amount Collected $13062.06 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Agreement Existing Prior to 1/1/87 Certificate issued by: Laurie Howard, Secretary Signature:Q,WI,`e� Not Subject_ to Fee Requirement NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether'payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V: c/mydocs/dev f ees, certi l icate o l' compl iance 11/2010 t il)i LYTY !NATIONAL TITLE COMPANY St I N`0VA2K r ', �1IAIL T0: Capetz, Robert 42-590 Brighton St. a m eser , CA 922t -t MAIL TAX STATEMENT TO: Same as above DOC ' a 2003-047055 01/22/2003 08:00A Fee:19.00 Page 1 of 5 Doc T Tax Paid Recorded in Official Records County of Riverside.. Gary L..Orso Assessor, County Clerk 6 Recorder Escrow# 6524-BAM DOCUMENT TRANSFER TAX $ ' 247.50 X M S/ U PAGE SIZE DAPCO�RNOCOR SMF MISC. A. R L COPY LONG REFUND NCHG EXAM Computed on the consideration or value of property conveyed; OR / Computed on the consideration or value less liens or encumbrances remaining at the time of sale. i THE UNDERSIGNED Signature of Declarant or Agent determining tax - Firm Name GRANT DEED. FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged; ND LA QUINTA PARTNERS, LLC, •a Delaware limited liability company ), ("Grantor" hereby, GRANT(S) to ROBERT •CAPETZ, A. MARRIED MAN** ("Grantee"), the real property located in the City..of La Quinta, County of Riverside, State of California, described as:. **AS HIS SOLE AND SEPERATE PROPERTY ' See Legal Description'attached hereto and incorporated herein as Exhibit "A". 'SUBJECT TO all matters of record including, without. limitation, the covenants and agreements described in Exhibit "A' attached hereto. Dated: 12-27-02 ND LA QUINTA PARTNERS, LLC; "a Delaware limited liability company I By: Nationwide Realty Investors, Ltd., "✓�' an Ohio limited liability company 011 its managing member / By: QrSa r cer - 1-LA/627969.1 1 EXHIBIT "A" Legal Description Parcel No. 1: Lot, 340 (the "Lot") of Amended Tract, No. 29894-2' • as shown on a Subdivision Map (the "Map") recorded on' December 12, 2002 in Book23 7 Pages to 88 , inclusive, of Maps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR; and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all or 'a. portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions -and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December -13 2002, as,Instrument No. 2002-745939 of Official Records of Riverside County, California (the "Official Records"); FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of,' twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by. Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental ' agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right. of entryis not complied with by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees. and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. ' SUBJECT TO: 1. Nondelinquent general, special and supplemental real property taxes and assessments. I��III IIIIII IIII IIIIII IIII IIIIII IIIII'lllIIII IIII IIII Fi1:�FJFJf .,4�offiRcRfiF 1-LA/627969.1 3 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without limitation, the Declaration and the Map for Tract No'. 29894-2 Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are -set, forth in the Declaration ,and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13. i5establishing the procedure. for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by _Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaration to which. this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto' Grantor and The Hideaway Owners Association such power and' rights which are set forth in the . Declaration defined above, on f — J �– , 20 TW C111 STATE OF Call-6rrlio_, ) ss. COUNTY OF IzyRXS) k , ` ) On anL&o_r 1 "20J before me, the undersigned, a notary public in and for said State, personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(x) whose name(s) is/fte subscribed to the within instrument and acknowledged to me that.he/s%e/they executed the same in his/her/tltair authorized capacity(ibs), and that by his/her/their signature(N on the instrument the .person(), or the entity upon behalf of which the person(IS) acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL'. Signature e;i [SEAL] :1 2/_,,.<. ..A 1-LA/627969A 4 .: KATHRYN L. HUNTER Commission # 1382692 Z .� Notary Public - California ; .- Riverside. County My Comm. Expires Nov 1', 2006 January 5, 2011 Mr. Rob Capetz P.O. Box 1144 La Quinta, "CA 92247 RE: : Capetz/Schematic Design Submittal Lot 340 at°53376 Via Bellagio Dear Mr. Capetz The Hideaway Design Review Committee met to review your "Schematic Submittal for Lot 340. The project is approved for you to move forward to the Preliminary Design Review level. Please have the following comments addressed with your next set. of plans: 1. Nothing over 3' is allowed in the view corridor. 2. The fire pit will need to be moved out of the view corridor. 3.. The water line for the pool can be no closer than 10' to the rear property line unless a variance form is submitted. A variance will only be allowed for the water line to be closer to the rear property line, the pool must be kept 10' from the side property line: 4. There is a 42' wall on the right side yard.with no break, this is not permitted per the Design Guidelines. 5. The 6', high side yard wall cannot extend beyond the Private Area°of the lot diagram. . Standard Notes: A mailbox design and location should be indicated on the plans in the event that the USPS. approves door- to-door mail delivery in the future.' Any Specific Plan information on file with the City of La Quinta will need to be included in your'plans. Any deviation from the Design Guidelines must be submitted with a request for Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process it will be the design team's responsibilityto make modifications at a laterrdate if requested by the Design Review Committee. All setback lines should be verified with the Lot Diagram by the Civil,Engineer. 3 Please. contact Mindy Gutierrez at (760) 393-5211 with any questions. We look forward to reciving your next set of plans for review. Sincerely; Hideaway Design Review Committee C: Jim DeFord, DRC File March 9, 2011 HIDEAWAY OWNERS ASSOCIATION Mr. Rob Capetz , P.O. Box 1144 La Quinta, CA 92247 RE: Capetz/ Preliminary Design Submittal #2 Lot 340 at 53376 Via Bellagio Dear Mr. Capetz: The Design Review Committee reviewed the plans and the architectural plans were approved, however, the landscape and grading plans could not be approved for Final Review. Please address the following and resubmit plans: 1. The grading plans now match; however, the slopes are not shown on the landscape plans. The slopes are kept to a maximum of 3 :1. 2- Please coordinate the 5 foot wall height and the transition to the 6 foot, property line wall at the auto court. The 6 foot height may not extend past the front set back: 3. Please add a cap to the front raised planters to match the pilasters on walls. 4. Is the planting proposed for the Natural Area consistent with the streetscape and golf course planting design? Please provide detail. 5. The palm Tree in the View Comdor requires written neighbor approval. Please provide. 6- Please confirm availability of 48" box Acacia's. 7. The courtyard water feature details are drawn atmore than 6 feet high and do not match the plan. 8. Callouts on plan and details do not agree. 9. There is insufficient room for planning to screen the BBQ.. 10. Please submit pots -for review. 11. Please provide tile cut sheets -or samples. 12. The Fire Bowl is still' in the View Corridor, which is not permitted. 13. The committee requests one complete full set of plans for approval: Please be aware that in the event the plans do not match what has been approved, construction could be held up at the set -back review. 14. A final review of the site and landscape plans will need to be done. . 15. The Infinity pool is not approved as -submitted. Please specify how the revised corner will be handled. We look forward to receiving your next set of plans for review. Please contact Roxi Bardwell at (760) 393-5211 with any questions. Sincerely, The Hideaway Design Review Committee cc: Jim D6ord, DRC File MAR 4. 2011 80955 Avenue 52 La Quinta, CA 92253 P: 760 393-5210 F: 760 398-5788 . a - a t BUILDING ENERGYANALYSIS REPORT PROJECT: New Residence 53376 Via Bellagio, The Hideaway La Quinta, CA 92253 Project Designer: Helton, DeFord & Associates 1261 N. Big Spring Street Anaheim, Ca 92807 (909) 957-4550 Report Prepared by: Tim Scott • f Scott Design and Title 24, Inc, ;rte, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE FOR CONSTRUCTION DATE Job Number: �� B Date: - 3/23/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Energ Soft User Number: 6712. RunCode: 2011-03-23T16:26:42 /D: C • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name New Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/23/2011 Project Address 53376 Via Bellagio, The Hideaway La Qu California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,398 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,398 Radiant Barrier New Wall Wood Framed R-21 3,270 New Slab Unheated Slab -on -Grade None 4,398 Perim = 384' New Door Opaque Door None 20 New FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Rear (E) 72.0 0.390 0.39 none none Bug Screen New Right (S) 100.0 0.390 0.39 none none Bug Screen New Front (W) 136.5 0.390 0.39 none none Bug Screen New Left (N) 8.0 0.390 0.39 none none Bug Screen New Left (NE) 12.0 0.390 0.39 none none Bug Screen New Left (NE) 9.0 0.390 0.39 none none Bug Screen New Left (NE) 40.0 0.390 0.39 none none Bug Screen New Rear (E) 80.0 0.390 0.39 none none Bug Screen New Rear (E) 200.0 0.390 0.39 10.0 none Bug Screen New Right (S) 80.0 0.390 0.39 10.0 none Bug Screen New Right (S) 84.0 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 All Pipes Ins New Energ Pro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-23716:26:42 ID: Page 3 of 27 M • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name New Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/23/2011 Project Address 53376 Via Bellagio, The Hideaway La Qu California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,398 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (w) 54.1 0.390 0.39 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-23T16:26:42 /D: Page 4 of 27 17J • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project NameBuilding New Residence 7❑ Type m Single Family ❑ Addition Alone Multi Family ❑ Existing+ Addition/Alteration Date 3/23/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 710.0 ftZ Covered Slab Floor, 3.500" thick at Zone 1 Master Suite HIGH MASS Design - Verify Thermal Mass: 309.0 ftz Exposed Slab Floor, 3.500" thick at Zone 1 Master Suite The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 499.0 ft' Covered Slab Floor, 3.500" thick at Bedroom 3 & 4 HIGH MASS Design - Verify Thermal Mass: 112.0 ft' Exposed Slab Floor, 3.500" thick at Bedroom 3 & 4 HIGH MASS Design - Verify Thermal Mass: 293.0 ftz Covered Slab Floor, 3.500" thick at Casita HIGH MASS Design - Verify Thermal Mass: 41.0 ft - Exposed Slab Floor, 3.500" thick at Casita The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design -Verity Thermal Mass: 1,993.0 ft - Exposed Slab Floor, 3.500" thick at Zone 3 & 4 Great/Mom/Kit/Din/Foyer HIGH MASS Design - Verify Thermal Mass: 441.0 It Covered Slab Floor, 3.500" thick at Zone 3 & 4 Great/Mom/qt/Din/Foyer The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS fled verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2011-03-23716:26:42 /D: Page 5 of 27 • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date New Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 3/23/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 1.64 2.09 -0.45 Space Cooling 77.09 55.31 21.78 Fans 15.33 15.77 -0.44 Domestic Hot Water 6.29 5.58 2.71 Pumps 0.00 0.00 0.00 Totals 102.36 78.76 23.60 Percent Better Than Standard: 23.1 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (M 290 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 I'm 1,520 191 Fuel Available at Site: Natural Gas (N) 1,057 69 Raised Floor Area: 0 (E) 1,028 352 Slab on Grade Area: 4,398 (S) 561 264 Average Ceiling Height: 11.9 Roof 4,398 0 Fenestration Average U -Factor: 0.39 TOTAL: 876 Average SHGC: 0.39 Fenestration/CFA Ratio: 19.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complet . Documentation Author Company Scott Design and Title 24, Inc, 3/23/2011 Address 77-085 Michigan Drive Name Tim Scott Cit /State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an E.pproved HERS rater. Designer or Owner (per Business & Professions Code) Company Helton, DeFord & Associates Address 1261 N. Big Spring Street Name Jim Deford City/State/Zip Anaheim, Ca 92807 Phone (909) 957-4550 Signed License # Date EnemyPro 5.1 by EnerqySoft User Number., 6712 Run Code: 2091-03-23T16:26:42 /D: Pa e 6 of 27 ME C CERTIFICATE OF COMPLIANCE:. Residential ' (Part 4 of 5) . CF -1 R Project Name New Residence Building Type O Single Family ❑ Addition Alone ❑ Multi Family . ❑ Existing+ Addition/Alteration Date 1312312011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,019 0.026 R-38 33 20 New 4.2.1-A9 Zone 1 Master Suite Wall 211 0.069 R-21 71 90 New 4.3.1-A6 Zone 1 Master Suite Wall 131 0.069 R-21 161 90 New 4.3.1-A6 Zone 1 Master Suite Wall 353 0.069 R-21 251 90 New 4.3.1-A6 Zone 1 Master Suite Wall 200.069 R-21 341 90 New _ 4.3.1-A6 Zone 1 Master Suite Slab 710 0.730 None '0 -180 New 4.4.7-A1 Zone 1 Master Suite Slab 309 0.730 None 0 180 New 4.4.7-A1 Zone 1 Master Suite Roof 611 0.026 R-38 33 • 20 New 4.2.1-A9 Zone 2 Bedrooms 3 & 4, Wall 231 0.069 R-21 251 90 New 4.3.1-A6 Zone 2 Bedrooms 3 & 4, Wall 52 0.069 R-21 341 90 New 4.3.1-A6 Zone 2 Bedrooms 3 & 4, Wall 100 0.069 R-21 20 90 New 4.3.1-A6 Zone 2 Bedrooms 3 & 4, Slab 499 0.730 None 0 180 New 4.4.7-A1 w ' Zone 2 Bedrooms 3 & 4, Slab -112 0.730 None 0 180 New 4.4.7-A 1 Zone 2 Bedrooms 3 & 4, Roof 334 0.026 R-38 33 20 New 14.2. 1-A9 Zone 2 Bedrooms 3 & 4, Wall 163 0.069 R-21 71 90 New 14.3.1-A6 Zone 2 Bedrooms 3 & 4, Wall 252 0.069 R-21 251 90 New 14.3.1-A6 Zone 2 Bedrooms 3 & 4, FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments ' 1 Wndow 15.0 0.390 NFRC 0.39 NFRC 71 New Double non-metal tinted Zone 1 Master Suite 2 . Wndow 100.0 0.390 NFRC 0.39 NFRC 161 New Double non-metal tinted Zone 1 Master Suite 3 Wndow 8.0 '0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 1 Master Suite 4 Wndow 33.0 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 1 Master Suite 5 window 8.0 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 1 Master Suite 6 Wndow 27.5 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 7 Wndow 27.5 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone.2 Bedrooms 3 & 4, Casit 8 Wndow 8.0 0.390 NFRC 0.39 NFRC 20 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 9 Window ' 24.0 0.390 NFRC 0.39 NFRC 71 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 10 Wndow 33.0 0.390 NFRC 0.39 NFRC 71 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 11 Wndow 8.0 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 12 Wndow 8.0 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 13 Wndow 16.5 0.390 NFRC 0.39 NFRC 251 New Double non-metal tinted Zone 2 Bedrooms 3 & 4, Casit 14 Wndow 12.0 • 0.390 NFRC 0.39 NFRC 50 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kitl 15, Wndow 3.0 0.390 1 NFRC 0.39 NFRC 50 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 16 Wndow 3.01 0.3901 NFRC 1 0.39 NFRC 1 50 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kitl (1) U -Factor Type: • 116-A =Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS - ID a Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Right Fin Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 -3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number., 6712 Run Code: 2011-03-23T16:26:42 ID: Pae 7 of 27 E CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name New Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1312312011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 160 0.069 R-21 3411 90 New 4.3.1-A6 Zone 2 Bedrooms 3 & 4, Slab 293 0.730 None 0 180 New 4.4.7-A1 Zone 2 Bedrooms 3 & 4, Slab 41 0.730 None 0 180 New 4.4.7-A1 Zone 2 Bedrooms 3 & 4, Roof 2,434 0.026 R-38 33 20 New 4.2.1-A9 Zone 3 & 4 Great/Momin Wall 423 0.069 R-21 50 90 New 4.3.1-A6 Zone 3 & 4 Great/Moming Wall 131 0.069 R-21 65 90 New 4.3.1-A6 Zone 3 & 4 GreatlMomibg. Wall 302 0.069 R-21 110 90 New 4.3.1-A6 Zone 3 & 4 Great/Morning, Wall 166 0.069 R-21 200 90 New 4.3.1-A6 Zone 3 & 4 Great/Moming Wall 254 0.069 R-21 290 90 New 4.3.1-A6 Zone 3 & 4 Great/Momin Wall 220 0.069 R-21 320 90 New 4.3.1-A6 Zone 3 & 4 Great/Moming Door 20 0.500 None 320 90 New 4.5.1-A4 Zone 3 & 4 Great/Morning, Wall 102 0.069 R-21 20 90 New 4.3.1-A6 Zone 3 & 4 GreatlMoming. Slab 1,993 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 Great/Momin Slab 441 0.730 None 0 180 New 4.4.7-A1 Zone 3 & 4 Great/Momin FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 3.0 0.390 NFRC 0.39 NFRC 50 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 18 Window 40.0 0.390 NFRC 0.39 NFRC 65 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 19 Window 80.0 0.390 NFRC 0.39 NFRC 110 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit( 20 Window 200.0 0.390 NFRC 0.39 NFRC 110 New Clad Wood Doors Zone 3 & 4 Great/Morning/KM 21 Window 80.0 0.390 NFRC 0.39 NFRC 200 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 22 Window 84.0 0.390 NFRC 0.39 NFRC 200 New Double non-metal tinted Zone 3 & 4 Great/Moming/Kit/ 23 window 10.4 0.390 NFRC 0.39 1 NFRC 290 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 24 Window 24.0 0.390 NFRC 0.39 NFRC 290 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit/ 25 Window 9.3 0.390 NFRC 0.39 NFRC 290 New Clad Wood Doors Zone 3 & 4 Great/Morning/Kit/ 26 Window 10.4 0.390 NFRC 0.39 NFRC 290 New Clad Wood Doors Zone 3 & 4 Great/Moming/Kit( (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len HgL LExt RExt Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 lBug Screen 0.76 10.0 20.01 10.0 0.1 10.0 10.0 21 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 22 Bug Screen 0.76 23 Bug Screen 0.76 8.0 1.3 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 1.2 6.2 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 8.0 1.3 2.0 0.1 2.0 2.0 EnergyPro, 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-23T16:26:42 ID: Page 8 of 27 r • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name New Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/23/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Zone 1 Master Suite 1,019 10,903 HVAC 2 Bedroom 3 & 4 611 6,599 Casita 334 3,474 HVAC 3 & 4 Zone 3 & 4 Great1Mom1Ki&Vin1Fc 2,434 31,155 Totals 4,3981 01 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 3 & 4 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 1 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o ¢ Sl System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 10 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-23T16:26:42 ID: Page 9 of 27 4 4 MANDATORY MEASURES SUMMARY:. Residential (Pagel of -3) MF -1 R Project Name ew Residence Date 3/23/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.' 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF. -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. 150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.," *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. ' §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. .Fire laces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake; which is at least six square inches in area and is e ui ped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Sace Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, um isolation valve, and recirculation loo connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances. (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnefgySoft User Number: 6712 RunCode: 2011-03-23T16:26:42 ID: Page 10 of 27 MANDATORY MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 'MF -1 R Project Name Date ew Residence 1312312011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number., 6712 RunCode: 2011-03-23716:26:42 ID: Page 11 of 27 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ew Residence 1312312011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically, reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occu ant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoif User Number: 6712 RunCode: 2011-03-23716:26:42 /D: Page 12 of 27 SYSTEM HEATING AND COOLING LOADS SUMMARY e FewjResidence Date 3/23/2011 me Floor Area HVAC 1 1,019 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System Sensible CFM Sensible Latent CFM Output per System 71,000 12,047 Total Room Loads 687 13,243 2,087 276 Total Output Btuh 71,000 Return Vented Lighting 0 Output Btuh/s ft 69.7 592 Return Air Ducts 764 Cooling System 0 Return Fan 0 Output per System 46,500 0 Ventilation 0 0 0 0 Total Output Btuh 46,500 0 Supply Fan 0 Total Output Tons 3.9 592 Supply Air Ducts 764 Total Output Btuh/s ft 45.6 Total Output s ftrron 263.0 1 13,231 TOTAL SYSTEM LOAD 1 14,771-12,087 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ACA448/58CVX090 32,354 4,929 71,000 Airflow cfm/s ft 1.57 71,000 Jan 1 AM Airflow cfm/Ton 412.9 Outside Air % 0.0% Total Adjusted System Output 32,354 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,929 Aug 3PM Outside Air cfm/s ft 0.00 Note: values above nivan at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 113 OF 113 OF Outside Air 0 cfm Heating Coil Supply Fan 1,600 cfm 113 OF R401M 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/59°F 52/51 OF 52/51 OF Outside Air - 0 cfm Cooling Coil Supply Fan 1,600 cfm 49.9% 52 / 51 F ........ ;.......... ..............................._..... i ROOttf1 70 / 59 OF 70/ 58 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-23T16:26:42 /D: Page 13 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ew Residence Date 3/23/2011 System Name HVAC 2 Floor Area 945 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 910 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 17,006 2,794 288 12,564 Total Output Btuh 71,000 0 Output Btuh/s ft 75.1 982 617 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 982 1 18,970 2,794 0 Total Output Tons 3.9 617 Total Output Btuh/s ft 49.2 Total Output s ft/Ton 243.9 1 13,799 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ACA448/58CVX090 31,867 5,657 71,000 Airflow cfm/s ft 1.69 Airflow cfm/Ton 412.9 Outside Air % 0.0% Total Adjusted System Output 31,867 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK . 5,657 Aug 3 PM 71,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 113 OF (ei�.` `'`—` • Heating Coil Supply Fan O 113 F 1,600 cfm Rt}0 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 /59°F 71 /59°F 52/51 OF 52/51 OF Cooling Coil Supply Fan 53 / 51 OF 1,600 cfm:..... ...... ................................. .... 51.3% ROOM III i 70/59°F EnergyPro5.1 by EnergySoft User Number. 6712 RunCode: 2011-03-23T16:26:42 /D: Page 14 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ew Residence Date 3/23/2011 System Name HVAC 3 & 4 Floor Area 2,434 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,646 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 31,570 3,874 728 31,581 Total Output Btuh 142,000 0 Output Btuh/s ft 58.3 1,822 1,552 Cooling System 0 0 Output erSystem 46,500 0 0 0 0 Total Output Btuh 93,000 0 1,822 1 35,215 3,874 0 Total Output Tons 7.8 1,552 Total Output Btuh/s ft 38.2 Total Output s ft/Ton 314.11 34,685 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Alrflow (cfm) 3,200 Carrier 24ACA448/58CVX090 65,004 9,550 142,000 Airflow cfm/s ft 1.31 142,000 F Jan 1 AM Airflow cfm/Ton) 412.9 Outside Air % 0.0% Total Adjusted System Output 65,004 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,550 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions MM'HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 113 OF Heating Coil Supply Fan 3,200 cfmROO I 112 o F OA 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 / 59 OF 71 /59°F 52/51 OF 52/51 OF Cooling Coil Supply Fan 52 / 51 OF 3,200 cfm:....... ..... ..... ....:............. ......................... 49.7% ROOM 70158 °F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-23716:26:42 ID: Page 15 of 27 :7 • • ROOM LOAD SUMMARY Project Name - Date New Residence 3/23/2011 System Name Floor Area HVAC 2 945 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFMSensible Latent CFM Sensible Zone 2 Bedrooms 3 & 4, Ca Bedroom 3 & 4 1 441 8,243 1,572 441 8,243 1,572 133 5,814 Casita 1 469 8,7641 1,222 469 8,764 1,222 155 6,749 PAGE TOTAL TOTAL 910 17,0061 2, 794 288 1Z564 910 17,006 2,794 288 12,564 Total includes ventilation load for zonal systems. EnemyPro 5.1 by EnerqySoft User Number. 6712 Run Code: 2011-03-23716:26:42 /D: Pae 17 of 27 • • 0 ROOM LOAD SUMMARY Project Name Date New Residence 3/23/2011 System Name Floor Area HVAC 3 & 4 2,434 ROOM LOAD SUMMARY ROOM COOLINN3,674 COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult.V1,6461 FM SensibleCFM Sensible Latent CFM Sensible Zone 3 & 4 Great/Moming Zone 3 & 4 Great/Mom/Ki 131,570 1,646 31,570 3,874 7281 31,581 PAGE TOTAL TOTAL* 1,646 31,5701 3,8741 728 31,581 1,6461 31,5701 3,8741 7281 31,581 * Total includes ventilation load for zonal systems. EnemyPrp 5.1 by EnemySoft User Number: 6712 Run Code: 2011-03-23716:26:42 ID: Pae 18 of 27 • 0 0 ROOM HEATING PEAK LOADS Project Name New Residence Date 312312011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Master Suite Floor Area 1,019.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr = 1,219 = 2,269 = 2,942 = 2,955 = = = = = = = = = = = = = = = = = = = = = = = = = = 9,385 46 = 2,662 R-38 Roof(R.38.2x14.16) 1,019.0 0.0260 46 R-21 Wall (W.19.2x6.16) 715.0 0.0690 46 Double non-metal tinted 164.0 0.3900 46 Slab -On -Grade perim = 88.0 0.7300 46 - Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 1,019 X Area another room 10.70 j( 0.297 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 12,047 EnergyPro 5.1 by EnergySoft . User Number: 6712 Run Code: 2011-03-23 71 6:26:42 /D: Page 19 of 27 r 1 U • ROOM HEATING PEAK LOADS Project Name New Residence Date . 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 & 4 Floor Area 611.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 of Conduction Area 611.0 X 383.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = - = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 0.0260 46 731 R-21 Wall (W.19.2x6.16) 0.0690 46 1,216 Double non-metal tinted 63.0 X 0.3900 46 1,130 Slab -On -Grade perim = 34.0 X 0.7300 46 1,142 X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 611 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction another room 10.80 X 0.294 Height ACH Page Total /60]. X AT 4.218 = 1,596 TOTAL HOURLY HEAT LOSS FOR ROOM 5,814 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-23T16:26:42 /D: Page 20 of 27 • • C] ROOM HEATING PEAK LOADS Project Name New Residence Date 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Floor Area 334.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X. X X X AT °F = = = = = = = = = = = = = = = = - = = = = = = = = = = _ = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 334.0 0.0260 46 399 R-21 Wall (W.19.2x6.16) 574.5 0.0690 46 1,823 Double non-metal tinted 89.5 0.3900 46 1,606 Slab -On -Grade perim = 61.0 0.7300 46 2,048 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction through an interior surface X 334 X Area another room 10.40 X 0.306 Height ACH Page Total /60] X AT 5,877 = 872 TOTAL HOURLY HEAT LOSS FOR ROOM 6.749 EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2011-03-23T16:26:42 /D: Page 21 of 27 • • ROOM HEATING PEAK LOADS Project Name New Residence Date 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 & 4 Great/Mom/Kit(Din/Foyer Time of Peak Jan 1 AM Floor Area 2,434.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value X X X X )( X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = - = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 2,434.0 X 0.0260 46 2,911 R-21 Wall (W. 19.2x6.16) 1,597.9 X X 0.0690 46 5,072 Clad Wood Doors 466.1 0.3900 46 8,362 Double non-metal tinted 93.0 X 0.3900 46 1,668 Wood Door 20.0 X X X X X 0.5000 46 460 Slab -On -Grade perim = 201.0 0.7300 46 6,750 X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 2,434 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.072 Schedule Air Sensible Fraction another room 12.80 X 0.248 Height ACH Page Total /60] X AT 25,223 = 6,358 TOTAL HOURLY HEAT LOSS FOR ROOM 31,581 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-23716:26:42 ID: Page 22 of 27 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date New Residence 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,019.0 ft- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (NE) 1,019.0 X 0.0260 X 56.0 = 1,484 R-21 Wall (W.19.2x6.16) (E) 211.0 X 0.0690 X 31.3 = 456 R-21 Wall (W.19.2x6.16) (S) 131.0 X 0.0690 X 28.1 = 254 R-21 Wall (W.19.2x6.16) (1/0 353.0 X 0.0690 X 32.2 = 783 R-21 Wall (W.19.2x6.16) (N) 20.0 X 0.0690 X 29.0 = .46 X X = X X = X X = X X = Page Total 3,017 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 105 (E) 0.0 X 22.3 + 15.0 X 40.9 = 614 1 M (S) 0.0 X 22.3 + 100.0 X 26.0 = 2,597 106 (W) 0.0 X 22.3 + 8.0 X 43.8 = 350 107 (W) 0.0 X 22.3 + 33.0 X 43.8 = 1,445 108 (W) 0.0 X 22.3 + 8.0 X 43.8 = 350 X + X - X + X - X + X - X + X - Page Total 5,358 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 820 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.072 X 0.94 X 55.76 X 42 = 2,348 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,243 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,806 X 0.94 X 55.76 X 0.00514 = 1,287 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM .2 087 Ene Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2011-03-23T16:26:42 /0: Page 23 of 27 I� • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date New Residence 1 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 & 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 611.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (NE) 611.0 X 0.0260 X 56.0 = 890 R-21 Wall (W. 19.2x6.16) (W) 231.0 X 0.0690 X 32.2 = 513 R-21 Wall (W. 19.2x6.16) (N) 52.0 X 0.0690 X 29.0 = 104 R-21 Wall (W. 19.2x6.16) (N) 100.0 X 0.0690 X 25.7 = 177 X X = X X = X X = X X = X X = Page Total 1,683 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation. Area GLF Area GLF Btu/hr 109 (W) 0.0 X 22.3 + 27.5 X 43.8 = 1,204 110 (lM 0.0 X 22.3 + 27.5 X 43.8 = 1,204 115 (N) 0.0 X 22.3 + 8.0 X 27.8 = 223 X + X = X + X = X + X = X + X = X + X = X + X = Page Total I 2,632 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/000. = 920 E ui ment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.072 X 0.94 X 33.43 X 42 = 1,408 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,243 Latent Gain Btu/hr Occupants 4•o Occupants X 200 Btuh/occ. = 800 Infiltration: 4,806 X 0.94 X 33.43 X 0.00514 = 772 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,572 EnemvPro 5.1 by EnemySoft User Number. 6712 Run Code: 2011-03-23T16:26:42 /D: Page 24 of 27 U • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date New Residence' 3/23/2011 ROOM. INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 11210F Floor Area 334.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dail Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (NE) 334.0 X 0.0260 X 56.0 = 486 R-21 Wall (W.19.2x6.16) (E) 163.0 X 0.0690 X 31.3 = 352 R-21 Wall (W. 19.2x6.16) W 251.5 X 0.0690 X 32.2 = 558 R-21 Wall (W. 19.2x6.16) (N), 160.0 X 0.0690 X 29.0 = 320 X X = X X = X X = X X = X X = Page Total 1,717 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr IP (E) 0.0 X 22.3 + 24.0 X 40.9 = 983 114 (E) 0.0 X 22.3 + 33.0 X 40.9 = 1,351 111 (lM 0.0 X 22.3 + 8.0 X 43.8 = 350 112 (lM 0.0 X 22.3 + 8.0 X 43.8 = 350 113 0.0 X 22.3 + 16.5 X 43.8 = 723 X + X = X + X - X + X - X + X = Page Total 3,757 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 E ui ment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.072 X 0.94 X 18.28 X 42 = 770 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,764 Latent Gain Btu/hr 'Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,806 X 0.94 X 18.28 X 0.00514.= 422 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,222 Ene Pro 5.1 by EneMVSoft User Number: 6712 Run Code: 2011-03-23T16:26:42 ID: Page 25 of 27 0 r RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name New Residence Date 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS' Room Name Zone 3 & 4 Great/Mom/Kit/Din/Foyer Outdoor Dry Bulb Temperature 112 OF Floor Area 2,434.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF Onaaue Surfaces R-38 Roof(R.38.2x14.16) . R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Wood Door R-21 Wall (w. 19.2x6.16) Orientation (NE) (NE) (NE) (E) (S) (1/109 (NKK (NIA9 (N) Area . X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,434.0 0.0260 56.0 423.0 0.0690 29.4 131.0 0.0690 30.8 302.0 0.0690 32.1 166.0 0.0690 28.2 253.9 0.0690 31.8 220.0 0.0690 29.9 20.0 0.5000 29.9 102.0 0.06901 25.7 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1F 102 103 104 1H 1J 1L 1K 100 Orientation (NE) (NE) (NE) (NE) (NE) (E) (E) (S) (S) Page Total Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 22.3 12.0 36.0 0.0 22.3 3.0 36.0 0.0 22.3 3.0 36.0 0.0 22.3 3.0 36.0 0.0 22.3 40.0 39.5 0.0 22.3 80.0 43.7 200.0 22.3 0.0 43.7 80.0 22.3 0.0 26.2 0.0 22.3 84.0 26.2 Page Total Internal Gain Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Ilnfiltration: 1.072 X 0.94 X 133.19 X 42 = Air Sensible CFM ELA AT Btu/hr 3,544 859 669 557 454 299 181 7, Btu/hr 432 108 108 108 1,581 3,497 4,454 1,782 2,198 14,2681 Btu/hr 920 1,600 5,608 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 31,5701 Latent Gain 4.0 Occupants X 1 200 Btuh/occ. Infiltration: 4,806 X 0.94 X 133.19 X 0.00514 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR Btu/hr 800 3,074 3.874 Pace 26 of 27 i • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date New Residence 1 3/23/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 3 & 4 Great/Mom/Kit/Din/Foyer Outdoor Dry Bulb Temperature 112 OF Floor Area 2,434.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1A (tM 1.0 X 22.3 + 9.4 X 40.7 = 404 1A (w) 2.4 X 22.3 + 21.6 X 40.7 = 933 1A (W) 6.1 X 22.3 + 3.2 X 40.7 = 266 1A (W) 1.0 X 22.3 + 9.4 X 40.7 = 404 X + X = X + X = X + X - X + X - X +1 X - Page Total 2,008 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.072 X 0.94 X 133.19 X 42 = 5,608 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 31,570 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,806 X 0.94 X 133.19 X 0.00514 = 3,074 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIRFOR ROOM 3. 874 Enem yPro 5.1 by Ene Soft User Number: 6712 RunCode: 2011-03-23716:26:42 /D: Page 27 of 27