Loading...
07-2337 (SFD)P.O. BOX 1504 'k /8-495 CALLE TAMPICO LA .QUINTA, CALIFORNIA 92253 T4hf 4 4v a" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00002337 Property Address: 53792 VIA BELLAGIO > APN: 772-510-058- - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 564550 Applicant: Architect or Engineer: Lic. No.: OOR SQUARE FOOT ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisi ns of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professio Is Code n y License is in full force and effect.; License Class: �B�/�� Licens o.: 838041 Date: 0& [ �i ntractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of peij r that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Busi ess and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also, requires the applicant for, the permit to file a signed statement that'he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cade) or that he or she is exempt therefrom and the basis for the alleged exemption. 'Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) l,as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The -.Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date Owner: • CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPE%IIIT Owner: JOHN READ 78150 CALLE TAMPICO.STE. 101 LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/19/07 Contractor: SOUTHERN HILLS DEVELOPMEN 78150 CALLE TAMPICO STE.10 LA QUINTA, CA 92253 CRY (760) 771-3497 F Lic. No.: 838041 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should becom ubj�heworkers'mpensation provisions of Section 3700 of the Labor Code, I shall o thwprovisions. Date: Applicant: WARNIN TO SECURE W RS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL ,. SUBJECT AN EMPLOYER TO CRIMI A PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITIO O THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, -AND ATTORNEY'S FEES.. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _ of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above informs is corre I agree to comply with all city and county ordinances and state laws relating to building c truct and h by thorize representatives of this cou')n`ttyy to enter upon the above-mentioned property for ns ect purpos s. Date: fir!' / ignature (Applicant or Agent): Application Number . . . . . 07-00002337 Permit . . . BUILDING PERMIT ( Additional desc . Permit Fee . . . . 2234.50 Plan Check Fee-. 1452.43 Issue Date . . . . Valuation . . . . 564550 Expiration Date 5/17/08 Qty Unit Charge Per Extension BASE FEE 2039.50 65.00 -----------------=---------------------------------------------------------- 3.0000 THOU BLDG 500,001-1,000,000 195.00 Permit. ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 278.22 Plan-Check Fee 69.56. Issue Date Valuation 0 Expiration Date 5/17/08 Qty Unit Charge. Per Extension BASE FEE 15.00 6508.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 227.78 1022.00 .0200 ELEC GARAGE.OR NON-RESIDENTIAL 20.44 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 5/17/08 Qty Unit Charge Per Extension -------------------=-----------------,--------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 207.50 Plan Check Fee 51.88 Issue Date Valuation . . . . 0 Expiration Date 5/17/08 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00 9.0000 EA MECH B/C <=3HP/100K BTU 54.00 12.00 6.5000 EA MECH VENT FAN 78.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 LQPE%NIIT A Application Number . e, . . . . 07-00002337 PermitPLUMBING , Additional desc . Permit Fee 238.50 Plan Check Fee 59.63 Issue Date . . . . Valuation 0 Expiration Date*. 5/17/08 Qty Unit Charge Per Extension BASE FEE 15.00 27.00 •6.0000 EA PLB FIXTURE 162.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7:5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00• 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB GAS METER 15.00 ------=--------------------------------------------------------------------- Special Notes and Comments 6508 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH. ------------------------------------_---------------------------------------- Other-Fees . . . . . . . .ART IN PUBLIC PLACES -RES 911.37 DIF COMMUNITY.CENTERS-RES 74.00 DIF CIVIC CENTER -'RES 995.00 ENERGY REVIEW FEE 145.24 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES' 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 COVE PRECISE PLAN FEE 100.00 . STRONG MOTION (SMI) - RES 56.45 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited ---------------------------------------------------------- Due Permit Fee Total 2973.72 .00 .00 2973.72 Plan Check Total 1633.50 1000.00 .00. 633.50 Other Fee Total 5703.06 .00 .00 5703.06 Grand Total 10310.28 1000.00 .00 9310.28 LQPE%MIT s Building 5 3 _ a Address P.O. BOX 1504 VIA 78 495 CALLE TAMPICO VIA .LA6�, iNTA, CALIFORNIA 92253 Address 7k)S-b CAL LG Tw 4PPico Sr/, I_J► Qu►.Li-m 17-71 35/97 A & Classif. 653 Xo q1 (Lia # L'S -9 7 Arch., Engr., AM -P,06!7- W, WCBC-k A t rQ I Designer RIF S-r9LtG,^URAL CO AJ 5"L7A�V Jr-, Address Tel. City (Zip (State I Lic. # LICENSED CON ACTOR' DECLARATION I hereby affirm that I am lice d u e provisi of Chapter 9 (commencing with Section 7000) of Division 3 of a Bu ss rofessi Code, and my license is in full force and effect. „ . Gl,i -2— OWNER-BUILDER DECLARATION I herebyaffirm at I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ 1, as owner o the property, am exclusively contracting with licensed contractors to construct the project. (S c. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) 01 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one h red dollars ($100) valuation or less). I certify that in the performance o e w for whic thi permit is issued, I shall not employ any person in any manner so a t be a subjec o orkers' Compensation Laws of Califo�r'a. Dated Owner NOTICE TO APPLICANT. If, of aking this Ce ificate of Exemption you should become subject to the Workers' Cotrifielilsation provisions of the Labor Code, you must forthwith comply with such provisions &&ffiis permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip of - x337 APPLICATION ONLY BUILDING: TYPE CONST. E C. GRP. A.P. Number Legal Description) Project Description Sq. Ft. No. No. Dw. Size :osO Stories Z Units New)Z Add ❑ Alter ❑ Repair ❑ Demolition ❑ N 1 L4 V, 014 -7 ? C_ 64LI— Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Q� Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS I I ,)1 tl I ? @, J:I I ow' at 1;J1.WW I��. ZONE: BY: r ! Minimum Setback Distances: �--- ---- 1 QTV Or LA Qt::;sTA Front Setback from CZet@r�L*in2* fid+: I Rear Setbac 'from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Ry Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) :398-5909 — Fax (760) 398-1224 Project Name: READ (Hideaway) This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK N: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: 12/21/07 Owner's Name: READ/ Southern Hills Development Phone No. (760) 835-8810 Project Address: 53-792 Via Bellagio, La Quinta, CA 92253 Project Description: 1 Single Family Dwelling APN: 772-510-058 Tract #: Lot #'s: Type of Development: Residential X% Commercial Industrial Total Square Feet of Building Area: 6,508 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/develope_r.� Dated: 12/21/07 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 6,508 sq. ft. Amount per Sq.Ft. $ 3.48 Amount Collected $ 22,647.84 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMkW OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this . time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T y CITY OF LA QUINTA PLAN CHECK CORRECTION LIST Andrez J. Weber, Architect October 16, 2007 74-133 El Paseo, Suite A Palm Desert, CA 92660 " (760) 340-3002 PLAN CHECK NO. 07-2337 SECOND CHECK/APPROVED (Structural) ADDRESS 53-792 Via Bellagio OCCUPANCY R -3/U-1 SCOPE OF WORK Living. Area: 5,546 S.F. TYPE -OF -CONST. V -N The. submitted plans and specifications have been reviewed by, the VCA.CODE GROUP. In, our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment. y r• APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING _ APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Perry astopoulos, VCA CODE GROUP 2200 W. Orangewood Avenue, Suite 155 Orange, CA. 92868 , (714) 363-4700 #756 VCA File No. LQ -20202 e, h CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 Green Sheet aa)rovals are forwarded to the Buildina & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date juerl /C`7 Developer: 6CL)7 IE�i?-iQ F�LL-`� 1JP� r � �'(V(Lyll3 i INC - Tract No.: t- - TractrName: (-j-1WAjd Y Lot No (s)- '2 Address(S): 5?,-- 7—ri� If. ..Ll i�ri. L1 f ,n Zq o-7 ct—Z- c_p ( -j;>o The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 AND #5 BELOW TRACT HOMES: PROVIDE ITEMS #1 #2, #3, #4 (AS APPLICABLE) AND #6 BELOW •:• COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1,.#2, #3 AND #5 -BELOW ❖ WALLS: PROVIDE ITEMS #7 BELOW ❖ SIGNS: PROVIDE ITEMS #8 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building Pad (maximum allowable deviation of +/- 0.1 foot).. Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please ithhold green sheet submittal until a Pad Elevation Certificate can be provided, ttach geotechnical certification of grading plan compliance. Attach recorded final map showing .proposed building locations are legal lots. Attach a completed. < 1. acre per lot or infill project Fugitive. Dust Control project information form, . PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM 10 plans for commercial & residential developments (beyond 1 lot) a bmitted separately with grading plans & are subject to additional requirements. Attach an approved precise grading plan for the building location(,). AO flood zone developments will require an approved flood .plain development plan.. S 6�r- � �- 6. Attach an approved rough grading plan for the building location(s). 7. Attach wall plan & related approved grading plan. 8. Attach sign layout/plan & related precise grading/landscape plan. have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the prop sed buildings/structures/walls/signs on the subject lot(s). Pursuant tomy s, the a o e rDat ct m b released for building permit issuance. Z Recommended b �/45y ated: Public Works Distribution: ( teen (. ) Greer Sheet to Building & Safety counter Sheet to Community Development �Yo Anticipates( Start Date: Project Street Anticipated Completion: address: Total acres in active construction (<1 acre per Lot): Z� U 3 -7117- Vi►A. 6r-_1 Project Contact Please Not Dust control. is required 24 hours a day, 7 days a week, .Information regardless of constructi t t P for dust control during on Q, a us. erson listed below is responsible business and non- business hours. of La Quinta - PM 10 Project Information < 1 acre Per. Lot or Infill V. Form updated & effective 8/25/2005 Project Information Project Contractor: Project Phase State: Project Phase Project Name: Zip Code: (Check One): Primary Telephone Construction Project Tract Numb.er:. l -Ze- Number: _:r ❑Demolition' -ZLot Number(s): Access/Emergency Anticipates( Start Date: Project Street Anticipated Completion: address: Total acres in active construction (<1 acre per Lot): Z� U 3 -7117- Vi►A. 6r-_1 Project Contact Please Not Dust control. is required 24 hours a day, 7 days a week, .Information regardless of constructi t t P Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. of 3 for dust control during on Q, a us. erson listed below is responsible business and non- business hours. Name: Title: V. Company Name: M.ailing,Addre:ss: —' City. L: Q, State: Zip Code: Primary Telephone Numb.er:. l -Ze- Fax: _:r 24 Hour Access/Emergency Phone: -5-5 Cell Phone: S 74 _�55 PM 10 Certificate Number: Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. of 3 . . of La Quinta. -'.Site. Specific. 'Construction Phase PM 10 Agreement � Agreement updated & effective 6125/2005 ' �> Shall act as his/her acknowledgement of dust contno/ 'requirements and -their' enforceability, ' . ��eabi|i�� pursuant ou4OK8ORules 4O3nnd4O3.1; ' Shall constitute and agreement to complywith ai''` '^' ''condhionaas ide^=�ed in the approved odat cnntro|p|an;The property owner (or authorized representative): . / ` ` ^ ` � Acknowledges thetdumtcontro| is required 24 hours aday x days o.»eak' th,oughoutthe of projectpe[fonnanue, regardless of p^"/eotoizO or status;' _ ShaU ' �noune that -each and every c -to '-----ntactor a'.= mU other persons osaouio�t8d�with-the project shall be �� continuous �mn��^ce.vith all '~,u�mnents�f n/�approved uoIcoUtrm| ` . ' Shall take all ' ~~~~'~�mry precautions to nininiz'adust, even if uoon//onal neooU»e� beyond dust control plan are necessary; - ' ` ` SM.�Uauthorize representative. ouhty t� enter upon the ab� ovomentioned orbpe rty abatement and � aUho|d "" harmless the- City/County and its representatives. liability any- re|6tadtm this dust control plan or any��itY/Cmunty initiated abatement---'-'�activities. " ` '^ U.yvne[or Authorize& epresentative ' Printed Name ' Title Date Company L Certificate of Occupancy d � Ixcowoanho �� roar G� OFBuilding Y p & Safer Department This Certificate .is issued pursuant to the requirements of Section 109 of the California Building - Code, certifying that, at the time of issuance, this structure was in , compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-792 VIA BELLAGIO i - Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-2337 Occupancy Group: R-3 Type of Construction: V -N " Land Use Zone: RL Owner of Building: JOHN READ Address: 78-150 CALLE TAMPICA STE 101 City, ST; ZIP: LA QUINTA, CA 92253 By: STEVE TRAXEL Date: DECEMBER 30, 2008 Building Official POST IN A CONSPICUOUS PLACE N TITLE 24 REPORT Title 24 Report for: Altman Residence 53 792 Via Bellagio La Quinta, CA 92253 , Project Designer: Andrzej W. Weber Architect AIA 74 133 EI Paseo, Suite A Palm Desert, CA 92210 760-340-3002 Report Prepared By: Wayne Seward, CEA R05-04-5184 Bear Technologys 7774 Calle Mejor .Carlsbad, CA 92009 (760) 635-2327 CITY OF LA QUANTA Job Number: BUILDING & SAFETY DEPT. 7Q4012 dl APPROVED FO CONSTR CTI �J � Date: DA BY 10/2/2007 �l OCT 1 n 2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report' This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 7Q4012 d1 User Number: 5956 Ai TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary T 1 2 3 8 10 11 EnergyPro 4.3 by EnergySoft Job Number: 7Q4012 d1 User Number: 5956 4. Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Altman RPsidenre Project Title x.3192 Via RPllaaio I Giuinta 10/2/2007 Date Project Address a Building Permit # Bear Technoloays (760) 635-2327 Documentation Author Telephone Plan Check/Date Ener yPro Compliance Method GA Climate Zone 15 Field Check/Date Climate Zone TDV Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 1.74 1.87 -0.13 Space Cooling 55.15 54.09 1.06 Fans. 7.81 7.59 0.22 Domestic Hot Water 3.71 2.89 0.82 Pumps 0.00 0.00 0.00 Totals 68.41 66.44 1.97 Percent better than Standard: 2.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRE Building Type: [kk Single Family ❑ Addition Total Conditioned Floor Area: 6,508 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 5,546 ft2 Fenestration: Average Ceiling Height: 10.4 ft Area: 1,133 ft2 Avg. U: 0.28 Number of Dwelling Units: 1.00 Ratio: 17.4% Avg. SHGC: 0.18 Number of Stories: 2 BUILDING ZONE INFORMATION Zone Name # of Thermostat Vent Floor Area Volume Units Zone Type Type Hgt. Area F 508908 R7 RR q 1 no C:nnditunnad Setback n/ OPAQUE SURFACES Insulation Act. Type Frame Area LI -Fac. Cay. Cont. Azm. Tilt Rnnf Wond 2 814 n 02R R-38 R -n n _0 1 Roof Wood 1758 0 036_ R-30 R-0.0 0 14 Wall Wood 842 0.074 R_19 R-0.0 a 90 Wall Wnnd 626 0.074 R-19 X0.0 n qfl Wall Wood 321 0.074 R_19 R-() 0 90 90 Wall Wood 763 0.074 R_19 R-0.0 180 gQ Wall Wond 565 0 074 R-19 R_0.0 270 90 Rnnf Wond 735 0096 R_38 R-0 0 n 14 Roof Wood 227 0.036 13-30 R-0.0 a 14 Wall Wood 427 0.074 X19 R-0 0 90 Wall Wood 268 0 074 R_19 R-0 n An A() Wall Wond 176 0.074 R_19 R_n 0 180 go Wall Wood 132 0.074 R_19 R-0.0 970 90 Gains Condition Y / N Status JA IV Reference Location / Comments Run Initiation Time: 10/02/07 15:41:48 Run Code: 1191364908 EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:3 of 11 ell Certificate Of Compliance : Residential Condition Status (Part 2 of 4) CF -1 R Altman Residence # Exterior Shade Type SHGC Hgt. 10/2/2007 Project Title Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 Date FENESTRATION SURFACES _ 2 Bug Screen 0.76 True Cond. Location/ # Type 0.76 Area U -Factors SHGCZ Azm. Tilt Stat. Glazing Type Comments L Skylight Front (N) 12.0 039 NFRC x.29 NFRC -0 14 New Skyleaht Lowe2/Arg 1 qt Floor Zone 2 Window Front (N) 92.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 1st Floor Zone 3 Window Front (N) 14.1 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 1st Floor Zone 4 Window Front (N) 54.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 1st Floor Zone 5 Window Front (N) 42.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 1 st Floor Zone 6 Window Front (N) 8.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 1st Floor Zone 7 Window Front (N) 6.0 0.280 NFRC0 18 NFRC 0 90 New MEL -A-216 1st Floor Zone 8 Window Left (E) 40.0 0.280 NFRC 0.18 NFRC 90 90 New MEL -A-216 1st Floor Zone 9 Window Left (E) 24.0 0.280 NFRC 0_18 NFRC 90 90 New MEL -A-216 1st Floor Zone 1Q Window Left (E) 6.0 0.28 NFRC 0.18 NFRC 90 90 New MEL -A-216 1st Floor Zone 0.76 Window Rear (S) 64.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 12 Window Rear (S) 6.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone _U Window Rear (S) 170.0 0.280 NERC 0.18 NFRC 180 90 New MEL -A-216 1st Floor Zone 14 Window Rear (S) 56.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 15 Window Rear (S) 97.5 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 16 Window Rear (S) 80.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 17 Window Rear (S) 99.0 0.280 NFRC 0_18 NFRC' 180 90 New MEL -A-216 1st Floor Zone 18 Window Rear (S) 42.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 19 Window Rear (S) 16.5 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 1st Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Condition Status Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 _ 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 _ 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 7.0 8.0 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 7.0 8.0 10.0 0.1 10.0 10.0 10 Bug Screen 0.76 7.0 8.0 10.0 0.1 10.0 10.0 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 322 None No Insulation 26-A1 New 1st Floor Zone Run Initiation Time: 10/02/07 15:41:48 Run Code: 1191364908 EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Altman Residence 10/2/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 2a Window Right (W) 8.0 0.280 NFRC JJa NFRC. -270_ 51.0_ New MEL -A-216 1st Floor Zone 21 Window Right (W) 16.0 0.280 NFRC 0_18 NFRC 270 90 New MEL -A-216 1st Floor Zone 22 Window Front (N) 20.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 2nd Floor Zone 23 Window Front (N) 20.0 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 2nd Floor Zone 24 Window Front (N) 6.7 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 2nd Floor Zone 25 Window Front (N) 6.7 0.280 NFRC 0_18 NFRC 0 90 New MEL -A-216 2nd Floor Zone 26 Window Front (N) 6.0 0.280 NFRC 0.18 NFRQ 0 90 New MEL -A-216 2nd Floor Zone 27 Window Left (E) 15.0 0.280 NFRC 0.18 NFRC 90 90 New MEL -A-216 2nd Floor Zone 28 Window Left (E) 15.0 0.280 NFRC 0.18 NFRC 90 90 New MEL -A-216 2nd Floor Zone ZQ Window Left (E) 6.0 0.280 NFRC 0.18 NFRC 90 90 New MEL -A-216 2nd Floor Zone 30 Window Rear (S) 3.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 2nd Floor Zone 31 Window Rear (S) 15.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 2nd Floor Zone Window Rear (,S) 54..0 0.28 NFRQ -018 NFRC 180 -9Q New MEL -A-216 2nd Floor Zone 33 Window Rear (S) 7.5 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 2nd Floor Zone 34 Window Rear (S) 5.0 0.280 NFRC 0_18 NFRC 180 90 New MEL -A-216 2nd Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 6.0 7.0 4.0 0.1 4.0 4.0 22 Bug Screen 0.76 _ 23 Bug Screen 0.76 24 Bug Screen 0.76. 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 _ 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (sf) (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Type Length R -Val. Insulation Location JA IV Reference Condition Status Location/ Comments I EnerovPro 4.3 by EnerovSoft User Number: 5956 Job Number: 7Q4012 dl Paae:5 of 11 I Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Altman Residence 10/2/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Central Furnace 78% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location Duct Coolina Location HVAC Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. 75 Gal Gas Generic Small Gas All Pipes Ins 1 75,000 75 New 0.72 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Attached Heating/Cooling load summary as well as the WS -5R are submitted as part of the calculations required by the current regulations. DO NOT USE FOR ACTUAL HEATING/COOLING or LIGHTING DESIGN. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Andrzej W. Weber Architect AIA Address: 74 133 EI Paseo, Suite A Palm Desefi, CA 92210 Teleph : 760-340- 02 Lic. #: 9 10 (gqn4Tr6r Cl/ NA t (date) Enorcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Wavne Seward. CEA R05-04-5184 Title/Firm: Bear Technoloqys Address: 7774 Calle Mejor -2907.100.002 Carlsbad. CA 92009 15!44!11 07'00' Telephone: (760) 635-2327 (signature) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Altman Residence 10/2/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adequacv of the justification, and may reject a building or design that otherwise complies >ased on the adequacy of the special justification and documentation submitted. I Plan I Field IThe Roof "R-38 Roof(R.38.2x12.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. I I HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods.Plan Field EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:7 of 11 1 Mandatory Measures Summary: Residential (Pagel of 2) ' MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ Q ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ Q ❑ 1. Masonry and factory -built fireplaces have: ❑ Q ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ 0 ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ Q ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ E ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ Q ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-13 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 704012 d1 Page:8 of 11 r_ Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑x ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ x❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑x ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:9 of 11 J Is- Residential % Residential Kitchen Lighting Worksheet WS -5R Altman Residence 10/2/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 2 ft Fluorescent T8 Elec Yes X No 22.0 x 13 = 286 or 1 26w Com act Fluorescent Triple 4 Pin Yes X1 No 1 28.0 x 13 = 364 or Recessed Incandescent Yes No X 60.0 x 8 = or 480 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x — or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 650 B: 480 COMPLIES IF A _t B YES ® NO ❑ EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 704012 d1 Page:10 of 11 1 L. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Altman Residence 10/2/2007 SYSTEM NAME FLOOR AREA HVAC 6,508 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 1 23,761 1,600 87,807 Furnance (78.0/14.0) 295,197 0 312,000 Total Adjusted System Output 295,197 --Jo 312,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm IF Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 0.0 OF 69.0 OF 69.0 OF 105.0 OF Outside Air 0 Supply Air Ducts 0 cfm Supply Fan Heating Coil 104.0 of 8000 cfm ROOMS 70.0 of 69.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 0.0 / 0.0 OF 78.3 / 49.1 OF 78.3 / 49.1 of 55.0 / 37.5 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.3 / 37.7 of 8000 cfm 4.3% R.H. ROOMS 78.3/49.1 of 78.0 / 48.9 of o .... A Q E I EneravPro 4.3 by EneravSoft User Number: 5956 Job Number: 7Q4012 d1 Page:11 of 11