07-2337 (SFD)P.O. BOX 1504
'k /8-495 CALLE TAMPICO
LA .QUINTA, CALIFORNIA 92253
T4hf 4 4v a"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 07-00002337
Property Address: 53792 VIA BELLAGIO
> APN: 772-510-058- -
Application description: DWELLING - SINGLE FAMILY DETACHED
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 564550
Applicant: Architect or Engineer:
Lic. No.: OOR SQUARE FOOT
-----------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisi ns of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professio Is Code n y License is in full force and effect.;
License Class:
�B�/�� Licens o.: 838041
Date: 0& [ �i ntractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of peij r that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Busi ess and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also, requires the applicant for, the
permit to file a signed statement that'he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cade) or
that he or she is exempt therefrom and the basis for the alleged exemption. 'Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) l,as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
-.Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date
Owner:
• CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPE%IIIT
Owner:
JOHN READ
78150 CALLE TAMPICO.STE. 101
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 11/19/07
Contractor:
SOUTHERN HILLS DEVELOPMEN
78150 CALLE TAMPICO STE.10
LA QUINTA, CA 92253 CRY
(760) 771-3497 F
Lic. No.: 838041
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier EXEMPT Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should becom ubj�heworkers'mpensation provisions of Section
3700 of the Labor Code, I shall o thwprovisions.
Date: Applicant:
WARNIN TO SECURE W RS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL ,.
SUBJECT AN EMPLOYER TO CRIMI A PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITIO O THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, -AND ATTORNEY'S FEES..
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above informs is corre I agree to comply with all
city and county ordinances and state laws relating to building c truct and h by thorize representatives
of this cou')n`ttyy to
enter upon the above-mentioned property for ns ect purpos s.
Date: fir!' / ignature (Applicant or Agent):
Application Number .
. . . . 07-00002337
Permit .
. . BUILDING PERMIT
( Additional desc
.
Permit Fee . .
. .
2234.50
Plan Check Fee-.
1452.43
Issue Date . .
. .
Valuation . . . .
564550
Expiration Date
5/17/08
Qty Unit
Charge
Per
Extension
BASE
FEE
2039.50
65.00
-----------------=----------------------------------------------------------
3.0000
THOU BLDG
500,001-1,000,000
195.00
Permit.
ELEC-NEW RESIDENTIAL
Additional desc
.
Permit Fee . .
. .
278.22
Plan-Check Fee
69.56.
Issue Date
Valuation
0
Expiration Date
5/17/08
Qty Unit
Charge.
Per
Extension
BASE
FEE
15.00
6508.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
227.78
1022.00
.0200
ELEC
GARAGE.OR NON-RESIDENTIAL
20.44
1.00 15.0000
----------------------------------------------------------------------------
EA ELEC
TEMPORARY POWER POLE
15.00
Permit . . .
. . GRADING PERMIT
Additional desc
.
Permit Fee
15.00
Plan Check Fee
.00
Issue Date
Valuation
0
Expiration Date
5/17/08
Qty Unit
Charge
Per
Extension
-------------------=-----------------,---------------------------------------
BASE
FEE
15.00
Permit .
. . MECHANICAL
Additional desc
.
Permit Fee . .
. .
207.50
Plan Check Fee
51.88
Issue Date
Valuation . . . .
0
Expiration Date
5/17/08
Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
6.00
9.0000
EA MECH
FURNACE <=100K
54.00
6.00
9.0000
EA MECH
B/C <=3HP/100K BTU
54.00
12.00
6.5000
EA MECH
VENT FAN
78.00
1.00
6.5000
EA MECH
EXHAUST HOOD
6.50
LQPE%NIIT
A Application Number .
e,
. . . . 07-00002337
PermitPLUMBING
,
Additional desc .
Permit Fee
238.50 Plan Check Fee
59.63
Issue Date . . . .
Valuation
0
Expiration Date*.
5/17/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00
27.00 •6.0000
EA PLB FIXTURE
162.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7:5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00•
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
16.00 .7500
EA PLB GAS PIPE >=5
12.00
1.00 15.0000
EA PLB GAS METER
15.00
------=---------------------------------------------------------------------
Special Notes and Comments
6508 SQ. FT. SFD THIS
PERMIT DOES NOT
INCLUDE POOL & SPA BLOCK WALLS OR
DRIVEWAY APPROACH.
------------------------------------_----------------------------------------
Other-Fees . . .
. . . . .ART IN PUBLIC PLACES -RES
911.37
DIF COMMUNITY.CENTERS-RES
74.00
DIF CIVIC CENTER -'RES
995.00
ENERGY REVIEW FEE
145.24
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
15.00
DIF LIBRARIES - RES'
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
COVE PRECISE PLAN FEE
100.00 .
STRONG MOTION (SMI) - RES
56.45
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1930.00
Fee summary Charged Paid Credited
----------------------------------------------------------
Due
Permit Fee Total
2973.72 .00 .00
2973.72
Plan Check Total
1633.50 1000.00 .00.
633.50
Other Fee Total
5703.06 .00 .00
5703.06
Grand Total
10310.28 1000.00 .00
9310.28
LQPE%MIT
s
Building 5 3 _ a
Address
P.O. BOX 1504
VIA
78 495 CALLE TAMPICO
VIA .LA6�, iNTA, CALIFORNIA 92253
Address 7k)S-b CAL LG Tw 4PPico Sr/,
I_J► Qu►.Li-m 17-71 35/97
A
& Classif. 653 Xo q1 (Lia # L'S -9 7
Arch., Engr., AM -P,06!7- W, WCBC-k A t rQ I
Designer RIF S-r9LtG,^URAL CO AJ 5"L7A�V Jr-,
Address Tel.
City (Zip (State I
Lic. #
LICENSED CON ACTOR' DECLARATION
I hereby affirm that I am lice d u e provisi of Chapter 9 (commencing with Section
7000) of Division 3 of a Bu ss rofessi Code, and my license is in full force and
effect. „ . Gl,i -2—
OWNER-BUILDER DECLARATION
I herebyaffirm at I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ 1, as owner o the property, am exclusively contracting with licensed contractors to construct
the project. (S c. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law)
01 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
O Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one h red dollars ($100) valuation
or less).
I certify that in the performance o e w for whic thi permit is issued, I shall not
employ any person in any manner so a t be a subjec o orkers' Compensation Laws of
Califo�r'a.
Dated Owner
NOTICE TO APPLICANT. If, of aking this Ce ificate of Exemption you should become
subject to the Workers' Cotrifielilsation provisions of the Labor Code, you must forthwith
comply with such provisions &&ffiis permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
of - x337
APPLICATION ONLY
BUILDING: TYPE CONST. E C. GRP.
A.P. Number
Legal Description)
Project Description
Sq. Ft. No. No. Dw.
Size :osO Stories Z Units
New)Z Add ❑ Alter ❑ Repair ❑ Demolition ❑
N
1 L4 V, 014 -7 ? C_ 64LI—
Estimated Valuation
PERMIT AMOUNT
Plan Chk. Dep. Q�
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
I I ,)1 tl I ? @,
J:I I ow'
at 1;J1.WW I��.
ZONE: BY: r !
Minimum Setback Distances: �--- ----
1 QTV Or LA Qt::;sTA
Front Setback from CZet@r�L*in2* fid+: I
Rear Setbac 'from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:
Validated by:
Validation:
Date Permit
WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE
Ry
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) :398-5909 — Fax (760) 398-1224
Project Name: READ (Hideaway)
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVELONEAMOUNT:
LEVELTWOAMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK N:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Date: 12/21/07
Owner's Name: READ/ Southern Hills Development Phone No. (760) 835-8810
Project Address: 53-792 Via Bellagio, La Quinta, CA 92253
Project Description: 1 Single Family Dwelling
APN: 772-510-058 Tract #: Lot #'s:
Type of Development: Residential X% Commercial Industrial
Total Square Feet of Building Area: 6,508 sq. Ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/develope_r.�
Dated: 12/21/07
Signature:
***********************************************************************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft. 6,508 sq. ft.
Amount per Sq.Ft. $ 3.48
Amount Collected $ 22,647.84
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Support Services
Certificate issued by: Leticia C. Torres, Facilities Analyst
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMkW OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this .
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
LT:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T
y
CITY OF LA QUINTA
PLAN CHECK CORRECTION LIST
Andrez J. Weber, Architect October 16, 2007
74-133 El Paseo, Suite A
Palm Desert, CA 92660 "
(760) 340-3002
PLAN CHECK NO. 07-2337 SECOND CHECK/APPROVED
(Structural)
ADDRESS 53-792 Via Bellagio OCCUPANCY R -3/U-1
SCOPE OF WORK Living. Area: 5,546 S.F. TYPE -OF -CONST. V -N
The. submitted plans and specifications have been reviewed by, the VCA.CODE GROUP. In, our
professional opinion the plans are in substantial conformance with the building codes and regulations
adopted by the CITY OF LA QUINTA and the State of California Amendment. y
r•
APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING _
APPROVALS/CLEARANCES FROM ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND
ASSOCIATIONS.
Plans checked by: Perry astopoulos,
VCA CODE GROUP
2200 W. Orangewood Avenue, Suite 155
Orange, CA. 92868 ,
(714) 363-4700 #756 VCA File No. LQ -20202
e, h
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 11/17/2006
Green Sheet aa)rovals are forwarded to the Buildina & Safety Department directly by Public Works.
Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department
until ALL requirements listed below are complete. Incomplete applications or applications which cannot
be processed will be returned to applicant.
Date juerl /C`7 Developer: 6CL)7 IE�i?-iQ F�LL-`� 1JP� r � �'(V(Lyll3 i INC -
Tract No.: t- - TractrName: (-j-1WAjd Y Lot No (s)- '2
Address(S): 5?,-- 7—ri� If. ..Ll i�ri. L1 f ,n
Zq o-7 ct—Z- c_p ( -j;>o
The following are the requirements for Public Works Clearance to authorize issuance of a building permit
from the Building & Safety Department:
❖ CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 AND #5 BELOW
TRACT HOMES: PROVIDE ITEMS #1 #2, #3, #4 (AS APPLICABLE) AND #6 BELOW
•:• COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1,.#2, #3 AND #5 -BELOW
❖ WALLS: PROVIDE ITEMS #7 BELOW
❖ SIGNS: PROVIDE ITEMS #8 BELOW
1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building
Pad (maximum allowable deviation of +/- 0.1 foot).. Pad Elevation Certificates must be current
(within 6 months of current date). If a precise grading plan creates the pad for approval, please
ithhold green sheet submittal until a Pad Elevation Certificate can be provided,
ttach geotechnical certification of grading plan compliance.
Attach recorded final map showing .proposed building locations are legal lots.
Attach a completed. < 1. acre per lot or infill project Fugitive. Dust Control project information form, .
PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference
number or hard copy plan. PM 10 plans for commercial & residential developments (beyond 1 lot)
a bmitted separately with grading plans & are subject to additional requirements.
Attach an approved precise grading plan for the building location(,). AO flood zone developments
will require an approved flood .plain development plan.. S 6�r- � �-
6. Attach an approved rough grading plan for the building location(s).
7. Attach wall plan & related approved grading plan.
8. Attach sign layout/plan & related precise grading/landscape plan.
have reviewed and confirmed the requirements listed above as presented and find the improvements to
be sufficiently complete for construction of the prop sed buildings/structures/walls/signs on the subject
lot(s). Pursuant tomy s, the a o e rDat
ct m b released for building permit issuance.
Z
Recommended b �/45y ated:
Public Works Distribution:
( teen
(. ) Greer
Sheet to Building & Safety counter
Sheet to Community Development
�Yo
Anticipates( Start Date:
Project Street
Anticipated
Completion: address:
Total acres in active
construction (<1 acre
per Lot):
Z� U
3 -7117- Vi►A. 6r-_1
Project Contact Please Not Dust control. is required 24 hours a day, 7 days a week,
.Information regardless of constructi t t P
for dust control during
on Q, a us. erson listed below is responsible
business and non- business hours.
of La Quinta - PM
10 Project Information
< 1 acre Per. Lot or Infill
V.
Form updated &
effective 8/25/2005
Project Information
Project Contractor:
Project Phase
State:
Project Phase
Project Name:
Zip Code:
(Check One):
Primary Telephone
Construction
Project Tract
Numb.er:.
l -Ze-
Number:
_:r
❑Demolition'
-ZLot
Number(s):
Access/Emergency
Anticipates( Start Date:
Project Street
Anticipated
Completion: address:
Total acres in active
construction (<1 acre
per Lot):
Z� U
3 -7117- Vi►A. 6r-_1
Project Contact Please Not Dust control. is required 24 hours a day, 7 days a week,
.Information regardless of constructi t t P
Expanded PM 10 plans for commercial and residential developments > 1 acre are required by
the City of La Quinta.
of 3
for dust control during
on Q, a us. erson listed below is responsible
business and non- business hours.
Name:
Title:
V.
Company Name:
M.ailing,Addre:ss:
—'
City.
L: Q,
State:
Zip Code:
Primary Telephone
Numb.er:.
l -Ze-
Fax:
_:r
24 Hour
Access/Emergency
Phone:
-5-5
Cell Phone:
S 74 _�55
PM 10 Certificate
Number:
Expanded PM 10 plans for commercial and residential developments > 1 acre are required by
the City of La Quinta.
of 3
. .
of La Quinta. -'.Site. Specific. 'Construction Phase PM 10 Agreement
�
Agreement updated & effective 6125/2005
'
�>
Shall act as his/her acknowledgement of dust contno/ 'requirements and -their' enforceability,
' . ��eabi|i��
pursuant ou4OK8ORules 4O3nnd4O3.1; '
Shall constitute
and agreement to complywith ai''` '^'
''condhionaas ide^=�ed in the approved
odat cnntro|p|an;The property owner (or authorized representative):
. /
`
` ^ `
�
Acknowledges thetdumtcontro| is required 24 hours aday x days o.»eak' th,oughoutthe of projectpe[fonnanue, regardless of p^"/eotoizO or status;'
_
ShaU '
�noune that -each and every c -to '-----ntactor a'.= mU other persons osaouio�t8d�with-the project shall be �� continuous �mn��^ce.vith all '~,u�mnents�f n/�approved uoIcoUtrm|
`
. '
Shall take all
' ~~~~'~�mry precautions to nininiz'adust, even if uoon//onal neooU»e� beyond dust control plan are necessary;
-
' `
` SM.�Uauthorize representative.
ouhty t� enter upon the ab� ovomentioned orbpe
rty abatement and
�
aUho|d
"" harmless the- City/County and its representatives. liability any- re|6tadtm
this dust control plan or any��itY/Cmunty initiated abatement---'-'�activities.
" `
'^
U.yvne[or Authorize& epresentative
'
Printed Name
'
Title
Date
Company
L Certificate of Occupancy
d
� Ixcowoanho ��
roar
G� OFBuilding Y p & Safer Department
This Certificate .is issued pursuant to the requirements of Section 109 of the California Building
-
Code, certifying that, at the time of issuance, this structure was in , compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 53-792 VIA BELLAGIO
i -
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-2337
Occupancy Group: R-3 Type of Construction: V -N " Land Use Zone: RL
Owner of Building: JOHN READ Address: 78-150 CALLE TAMPICA STE 101
City, ST; ZIP: LA QUINTA, CA 92253
By: STEVE TRAXEL
Date: DECEMBER 30, 2008
Building Official
POST IN A CONSPICUOUS PLACE
N
TITLE 24 REPORT
Title 24 Report for:
Altman Residence
53 792 Via Bellagio
La Quinta, CA 92253 ,
Project Designer:
Andrzej W. Weber Architect AIA
74 133 EI Paseo, Suite A
Palm Desert, CA 92210
760-340-3002
Report Prepared By:
Wayne Seward, CEA R05-04-5184
Bear Technologys
7774 Calle Mejor
.Carlsbad, CA 92009
(760) 635-2327
CITY OF LA QUANTA Job Number:
BUILDING & SAFETY DEPT. 7Q4012 dl
APPROVED
FO CONSTR CTI �J
� Date:
DA BY
10/2/2007
�l OCT 1 n 2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report' This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.3 by EnergySoft Job Number: 7Q4012 d1 User Number: 5956
Ai
TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -5R Residential Kitchen Lighting
HVAC System Heating and Cooling Loads Summary
T
1
2
3
8
10
11
EnergyPro 4.3 by EnergySoft Job Number: 7Q4012 d1 User Number: 5956
4.
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
Altman RPsidenre
Project Title
x.3192 Via RPllaaio
I Giuinta
10/2/2007
Date
Project Address
a
Building Permit #
Bear Technoloays
(760) 635-2327
Documentation Author
Telephone Plan Check/Date
Ener yPro
Compliance Method
GA Climate Zone 15 Field Check/Date
Climate Zone
TDV
Standard
Proposed
Compliance
(kBtulsf-yr)
Design
Design
Margin
Space Heating
1.74
1.87
-0.13
Space Cooling
55.15
54.09
1.06
Fans.
7.81
7.59
0.22
Domestic Hot Water
3.71
2.89
0.82
Pumps
0.00
0.00
0.00
Totals
68.41
66.44
1.97
Percent better than
Standard:
2.9%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRE
Building Type:
[kk Single Family
❑ Addition
Total Conditioned Floor Area:
6,508 ft2
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a ft2
Building Front Orientation:
(N) 0 deg
Raised Floor Area:
0 ft2
Fuel Type:
Natural Gas
Slab on Grade Area:
5,546 ft2
Fenestration:
Average Ceiling Height:
10.4 ft
Area: 1,133 ft2 Avg. U: 0.28 Number of Dwelling Units: 1.00
Ratio: 17.4% Avg. SHGC: 0.18 Number of Stories: 2
BUILDING ZONE INFORMATION
Zone Name
# of Thermostat Vent
Floor Area Volume Units Zone Type Type Hgt. Area
F 508908 R7 RR q 1 no C:nnditunnad Setback n/
OPAQUE SURFACES Insulation Act.
Type Frame Area LI -Fac. Cay. Cont. Azm. Tilt
Rnnf Wond 2 814 n 02R R-38 R -n n _0 1
Roof Wood 1758 0 036_ R-30 R-0.0 0 14
Wall Wood 842 0.074 R_19 R-0.0 a 90
Wall Wnnd 626 0.074 R-19 X0.0 n qfl
Wall Wood 321 0.074 R_19 R-() 0 90 90
Wall Wood 763 0.074 R_19 R-0.0 180 gQ
Wall Wond 565 0 074 R-19 R_0.0 270 90
Rnnf Wond 735 0096 R_38 R-0 0 n 14
Roof Wood 227 0.036 13-30 R-0.0 a 14
Wall Wood 427 0.074 X19 R-0 0 90
Wall Wood 268 0 074 R_19 R-0 n An A()
Wall Wond 176 0.074 R_19 R_n 0 180 go
Wall Wood 132 0.074 R_19 R-0.0 970 90
Gains Condition
Y / N Status JA IV Reference Location / Comments
Run Initiation Time: 10/02/07 15:41:48 Run Code: 1191364908
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:3 of 11
ell
Certificate Of Compliance
: Residential
Condition
Status
(Part 2 of 4) CF -1 R
Altman Residence
#
Exterior Shade Type
SHGC
Hgt.
10/2/2007
Project Title
Hgt.
LExt.
RExt. Dist. Len. Hgt. Dist. Len. Hgt.
1
None
1.00
Date
FENESTRATION SURFACES
_
2
Bug Screen
0.76
True
Cond.
Location/
#
Type
0.76
Area
U -Factors SHGCZ
Azm. Tilt
Stat. Glazing Type
Comments
L
Skylight
Front
(N)
12.0 039 NFRC x.29 NFRC -0 14 New Skyleaht Lowe2/Arg
1 qt Floor Zone
2
Window
Front
(N)
92.0
0.280 NFRC 0_18 NFRC
0 90 New
MEL -A-216
1st Floor Zone
3
Window
Front
(N)
14.1
0.280 NFRC 0_18 NFRC
0 90 New
MEL -A-216
1st Floor Zone
4
Window
Front
(N)
54.0
0.280 NFRC 0_18 NFRC
0 90 New
MEL -A-216
1st Floor Zone
5
Window
Front
(N)
42.0
0.280 NFRC 0_18 NFRC
0 90 New
MEL -A-216
1 st Floor Zone
6
Window
Front
(N)
8.0
0.280 NFRC 0_18 NFRC
0 90 New
MEL -A-216
1st Floor Zone
7
Window
Front
(N)
6.0 0.280 NFRC0 18 NFRC
0 90 New
MEL -A-216
1st Floor Zone
8
Window
Left
(E)
40.0
0.280 NFRC 0.18 NFRC
90 90 New
MEL -A-216
1st Floor Zone
9
Window
Left
(E)
24.0 0.280 NFRC 0_18 NFRC
90 90 New
MEL -A-216
1st Floor Zone
1Q
Window
Left
(E)
6.0 0.28 NFRC 0.18 NFRC 90 90 New
MEL -A-216
1st Floor Zone
0.76
Window
Rear
(S)
64.0
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
12
Window
Rear
(S)
6.0
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
_U
Window
Rear
(S)
170.0 0.280 NERC 0.18 NFRC 180 90 New MEL -A-216
1st Floor Zone
14
Window
Rear
(S)
56.0
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
15
Window
Rear
(S)
97.5
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
16
Window
Rear
(S)
80.0
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
17
Window
Rear
(S)
99.0
0.280 NFRC 0_18 NFRC'
180 90 New
MEL -A-216
1st Floor Zone
18
Window
Rear
(S)
42.0
0.280 NFRC 0_18 NFRC
180 90 New
MEL -A-216
1st Floor Zone
19
Window
Rear
(S)
16.5
0.280 NFRC 0_18 NFRC
180 90 New MEL -A-216
1st Floor Zone
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window
Condition
Status
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LExt.
RExt. Dist. Len. Hgt. Dist. Len. Hgt.
1
None
1.00
_
2
Bug Screen
0.76
_
3
Bug Screen
0.76
_
4
Bug Screen
0.76
_
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
7.0
8.0
10.0
0.1
10.0
10.0
9
Bug Screen
0.76
7.0
8.0
10.0
0.1
10.0
10.0
10
Bug Screen
0.76
7.0
8.0
10.0
0.1
10.0
10.0
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Type
Area Thick. Heat Inside
(sf) (in.) Cap. Cond. R -Val. JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type
Length R -Val. Location JA IV Reference
Status
Comments
Slab Perimeter
322 None No Insulation 26-A1
New
1st Floor Zone
Run Initiation Time: 10/02/07 15:41:48 Run Code: 1191364908
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:4 of 11
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
Altman Residence 10/2/2007
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments
2a
Window
Right
(W)
8.0 0.280 NFRC JJa NFRC. -270_ 51.0_ New MEL -A-216
1st Floor Zone
21
Window
Right
(W)
16.0 0.280 NFRC 0_18 NFRC
270
90 New MEL -A-216
1st Floor Zone
22
Window
Front
(N)
20.0 0.280 NFRC 0_18 NFRC
0
90 New MEL -A-216
2nd Floor Zone
23
Window
Front
(N)
20.0 0.280 NFRC 0_18 NFRC
0
90 New MEL -A-216
2nd Floor Zone
24
Window
Front
(N)
6.7 0.280 NFRC 0_18 NFRC
0
90 New MEL -A-216
2nd Floor Zone
25
Window
Front
(N)
6.7 0.280 NFRC 0_18 NFRC
0
90 New MEL -A-216
2nd Floor Zone
26
Window
Front
(N)
6.0 0.280 NFRC 0.18 NFRQ
0
90 New MEL -A-216
2nd Floor Zone
27
Window
Left
(E)
15.0 0.280 NFRC 0.18 NFRC
90
90 New MEL -A-216
2nd Floor Zone
28
Window
Left
(E)
15.0 0.280 NFRC 0.18 NFRC 90
90 New MEL -A-216
2nd Floor Zone
ZQ
Window
Left
(E)
6.0 0.280 NFRC 0.18 NFRC
90
90 New MEL -A-216
2nd Floor Zone
30
Window
Rear
(S)
3.0 0.280 NFRC 0_18 NFRC
180
90 New MEL -A-216
2nd Floor Zone
31
Window
Rear
(S)
15.0 0.280 NFRC 0_18 NFRC
180
90 New MEL -A-216
2nd Floor Zone
Window
Rear
(,S)
54..0 0.28 NFRQ -018 NFRC 180
-9Q New MEL -A-216
2nd Floor Zone
33
Window
Rear
(S)
7.5 0.280 NFRC 0_18 NFRC
180
90 New MEL -A-216
2nd Floor Zone
34
Window
Rear
(S)
5.0 0.280 NFRC 0_18 NFRC
180
90 New MEL -A-216
2nd Floor Zone
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt.
20
Bug Screen
0.76
21
Bug Screen
0.76 6.0 7.0 4.0 0.1 4.0 4.0
22
Bug Screen
0.76 _
23
Bug Screen
0.76
24
Bug Screen
0.76.
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76 _
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
33
Bug Screen
0.76
34
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Type (sf) (in.) Cap.
Inside
Cond. R -Val. JA IV Reference
Condition
Status
Location/
Comments
PERIMETER LOSSES
Type Length R -Val.
Insulation
Location JA IV Reference
Condition
Status
Location/
Comments
I EnerovPro 4.3 by EnerovSoft User Number: 5956 Job Number: 7Q4012 dl Paae:5 of 11 I
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
Altman Residence 10/2/2007
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC Central Furnace 78% AFUE Split Air Conditioner 14.0 SEER New Setback
HVAC DISTRIBUTION
Location
Duct
Coolina Location
HVAC Ducted Ducted
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Duct Condition Ducts
R -Value Status Tested?
4.2 New No
WATER HEATING SYSTEMS Rated
Tank
Energy
Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Standby R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE
Loss (%) Ext.
75 Gal Gas Generic Small Gas All Pipes Ins 1 75,000
75
New 0.72
n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
Attached Heating/Cooling load summary as well as the WS -5R are submitted as part of the calculations required by the current regulations.
DO NOT USE FOR ACTUAL HEATING/COOLING or LIGHTING DESIGN.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Andrzej W. Weber Architect AIA
Address: 74 133 EI Paseo, Suite A
Palm Desefi, CA 92210
Teleph : 760-340- 02 Lic. #:
9 10
(gqn4Tr6r Cl/ NA t (date)
Enorcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
Documentation Author
Name: Wavne Seward. CEA R05-04-5184
Title/Firm: Bear Technoloqys
Address: 7774 Calle Mejor -2907.100.002
Carlsbad. CA 92009 15!44!11 07'00'
Telephone: (760) 635-2327
(signature) (date)
Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R
Altman Residence 10/2/2007
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agencv determines the adequacv of the justification, and may reject a building or design that otherwise complies
>ased on the adequacy of the special justification and documentation submitted. I Plan I Field
IThe Roof "R-38 Roof(R.38.2x12.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. I I
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a
HERS provider using approved testing and/or verification methods.Plan Field
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1 Page:7 of 11 1
Mandatory Measures Summary: Residential (Pagel of 2) ' MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
Q
❑
*§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
�§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
❑
❑
❑
�§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
❑
Q
❑
1. Masonry and factory -built fireplaces have:
❑
Q
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑X
❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
❑
0
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑
❑
CF -6R Form:
❑
❑
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
Q
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
E
❑
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed.
❑
❑
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
Q
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
Q
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
0
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-13 and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 704012 d1
Page:8 of 11
r_
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑
❑
❑
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
❑
❑
dampers.
❑
❑
❑
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
❑X
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
❑
❑
❑
❑
®
❑
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑
❑
❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑
❑
❑
b. Cover for outdoor pools or outdoor spas.
❑
❑
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑
❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑
❑x
❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑
❑
❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑
x❑
❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑
Q
❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑
❑X
❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑
X❑
❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑
❑X
❑
controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑
❑X
❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑
❑x
❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑
❑
❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑
❑
❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section
119(d).
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 7Q4012 d1
Page:9 of 11
J Is-
Residential
%
Residential Kitchen Lighting Worksheet WS -5R
Altman Residence 10/2/2007
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
(1) 2 ft Fluorescent T8 Elec Yes X No 22.0 x 13 = 286 or
1 26w Com act Fluorescent Triple 4 Pin Yes X1 No 1 28.0 x 13 = 364 or
Recessed Incandescent Yes No X 60.0 x 8 = or 480
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes I No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x — or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 650 B: 480
COMPLIES IF A _t B YES ® NO ❑
EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 704012 d1 Page:10 of 11 1
L.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Altman Residence 10/2/2007
SYSTEM NAME FLOOR AREA
HVAC 6,508
SYSTEM LOAD
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel Latent
CFM
I Sensible
1 23,761 1,600
87,807
Furnance (78.0/14.0) 295,197 0 312,000
Total Adjusted System Output 295,197 --Jo 312,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm IF Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
0.0 OF 69.0 OF 69.0 OF 105.0 OF
Outside Air
0 Supply Air Ducts
0 cfm Supply Fan Heating Coil 104.0 of
8000 cfm ROOMS
70.0 of
69.0 of I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
0.0 / 0.0 OF 78.3 / 49.1 OF 78.3 / 49.1 of 55.0 / 37.5 OF
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 55.3 / 37.7 of
8000 cfm 4.3% R.H. ROOMS
78.3/49.1 of 78.0 / 48.9 of
o ....
A Q E I
EneravPro 4.3 by EneravSoft User Number: 5956 Job Number: 7Q4012 d1 Page:11 of 11