Loading...
BRES2016-0163 (2)78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: BRES2016-0163 53581 VIA BELLAGIO T41y 4 4� Q" DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT 777170006 MR.PISCIOTTA / REPLACE FIRE PLACE REMODEL $90,000.00 Applicant: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 AUG 0 9 2015 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 457228 Date: R Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered'for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec.. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/9/2016 Owner: PISCIOTTA 53581 VIA BELLAGIO LA QUINTA, CA 92253 Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 . (760)413-8863 Llc. No.: 457228 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of h work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by. Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9045509 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith complyytith lose �rovjsions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND -DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant,, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. J certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction; and hereby authorize representatives of this city to ente in the above -menti ned property for inspection purposes. Date: Signature (Applicant or Agent): ' Date: 8/9/2016 Application Number: BRES2016-0163 Owner: Property Address: 53581 VIA BELLAGIO PISCIOTTA APN: 777170006 53581 VIA BELLAGIO Application Description: MR.PISCIOTTA [REPLACE FIRE PLACE REMODEL LA QUINTA, CA 92253 Property Zoning: Application Valuation: $90,000.00 Applicant: Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 INDIO, CA 92201 (760)413-8863 -------------------------------=----------------------.--------------------------------------- Llc. No.: 457228 Detail: REMODEL TO EXISTING 4,712 SF SFD . REPLACE TWO FIREPLACES, REMOVE EXTERIOR ARCHES AT GARAGE AND ENTRY. RMODEL INTERIOR LIVING ARA AS NOTED ON ENGINEERED PLANS, ADD NEW LIGHTING SWITCHES, RELOCATE HVAC REGISTERS. REMODEL MASTER BATH. ADD NE WINDOWS. 2013 CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE -YES ADMINISTRATIVE STAFF 101-0000-42600 0.5 $20.00 ' DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE-' YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 4.5 $427.50 Total Paid for BLDG CITY STAFF - PER HOUR: $447.50 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $4.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $4.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, ADDITIONAL 101-0000-42403 0 $179.08 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, ADDITIONAL PC 101-0000-42600 0 $44.40 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $24.17 DESCRIPTION ACCOUNT • QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 Total Paid for ELECTRICAL: $271.82 DESCRIPTION ACCOUNT QTY AMOUNT FIREPLACE 101-0000-42400 0 $290.06 DESCRIPTION ACCOUNT QTY AMOUNT FIREPLACE PC 101-0000-42600 0 $435.10 Total Paid for FIREPLACE: $725.16 DESCRIPTION ACCOUNT QTY AMOUNT OTHER.MECHANICAL EQUIPMENT 101-0000-42402 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $36.26 Total Paid for"MECHANICAL: $72.52 DESCRIPTION ACCOUNT. QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $72.54 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $72.54 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 Total Paid for PLUMBING FEES: $169.26 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $11.70 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $11.70 DESCRIPTION ACCOUNT QTY AMOUNT ' STUCCO APPLICATION, FIRST 500 SF' 1101-0000-42404 0 $24.66 DESCRIPTION 'ACCOUNT CITY AMOUNT STUCCO APPLICATION, FIRST 500 SF PC 101-0000-42600 0 $73.97 Total Paid for STUCCO APPLICATION: $98.63 DESCRIPTION ACCOUNT- CITY AMOUNT DOOR/WINDOW, REPLACE FIRST •101-0000-42400 :0 $60.91 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW; REPLACE, FIRST 7 PC 101-0000-42600 0 $110.22 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 TOTALS: $1,971.72 n J x n Din # - City of La Quin to Building 8r• Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 J Building Permit Application and Tracking Sheet Permit # S c�0, Project Address: 1153 4��lAMt Owner's Name: S A. P. Number: 1(' 1N.4 Address: 5'5 Legal escription:City, ST, Zip: ,� G Contr to, t% i Telephone: TP Address: Q L (� 4� Project Description: City, ST, Zip: Telephone: hone: '?7 �0 r w State Lie. #: A CLI?i City Lie. Arch., Engr.; Desi per: Address: V7: P • S o' RECORDING REQUESTED BY: Lawyers Title Company WHEN RECORDED MAIL TO: MAIL TAX STATEMENTS TO: Larry Pisciotta 5500 Quincy Avenue Englewood, C0.80113 AUG 0 9 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT THIS SPACE FOR RECORDER'S USE ONLY: Order # 61,6692359, Escrow # 065994 -TT APN: 777-170-006-9 TRA: 020-160 GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $ 2,200.00 [X] computed on full value of property conveyed, or [ J computed on full value less value of liens or encumbrances remaining at time of sale. [ J Unincorporated area [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged: Jayne C. Hilde and Al Hilde, Jr., Trustees of The Jayne C. Hilde La Quinta Qualified Personal Residence Trust U/A dated July 5, 2011, as to an undivided 50% interest and Richard H. Palmer, Co -Trustee of The AH/JCH Trust U/A dated January 30, 1995, . as to an undivided 50% interest; as Tenants in Common hereby GRANT(s) to: Larry Pisciotta, a Married Man as His Sole and Separate Property the real property in the City of La Quinta, County of Riverside, State of California, described as: LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF 'This deed shall be signed in counterpart and together shall be considered one document" DATED: April 21, 2016 Signature Page attached hereto and made a part hereof Title Order No.: 616692359 . Title of Document: GRANT DEED Date of Document: April 21, 2016 Escrow No.: 065994 -TT SIGNATURE PAGE AP#: 777-170-006-9 s The Jayne CHilde La Quinta Qualified Personal Residence Trust U/A dated July 5, 2011 By r., The AH/JCH Trust U/A dated January 30, 1995 By: Richard H. Palmer, Co -Trustee ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate i attached, and not the truthfulness, accuracy, or validity of that document. STATE OF 04.1 1l4(r COUNTY OF Ar ( On r 1 1 z{p I �p before me, JTi C A Notary Public personally appeared �QV h'e C �� e n7A l W e—. -.3y who proved to me on the bAsis of satisfactory evidence to be the persons whose named iB/ate subscribed to the within instrument and acknowledged to me that he/she/t� executed the same in his/her/their authorized capacity(ies), and that by hWMr/their signature on the instrument the person(§), or the entity upon behalf o�which the person(s) acteTexecuted the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct.. WITNESS my hand and official seal. Signatur , (Seal) -0 TRACY A. THIEL COMM, # 2068535 U' NOTARY PUBLIC -CALIFORNIAG RIVERSIDE COUNTY 0 a COMM. EXPIRES JUNE 13, 2018 •j • r Title Order No.: 616692359 Title of Document: GRANT DEED Date of Document: April 21, 2016 r Escrow No.: 065994 -TT SIGNATURE PAGE AP#: 777-170-006-9 The Jayne C. Hilde La Quinta Qualified Personal Residence Trust U/A dated July 5, 2011 By: Jayne C. Hilde, Trustee By: - Al Hilde, Jr., Trustee The AH/JCH Trust U/A dated January 30, 1995 By: ichard H. Palmer, Co -Trustee ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF WYoMit-Or COUNTY OF On�tT Zq r o t before me, rt� W ttrw A Notary Public personally appeared �► G �'Cst - -T aL I VI't.e who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature (Seal) Tyrol Wray - Notary Public County of State of Teton Wyoming kly.Cammtssion Expires - -101 EXHIBIT "A" THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS.DESCRIBED AS FOLLOWS: PARCEL 1; LOT 318 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 327, PAGES 56 THROUGH 88, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. . EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS, AND FOR OTHER PURPOSES, ALL AS:DESCRIBED IN THE DECLARATION, RECORDED DECEMBER 13, 2002 AS INSTRUMENT NO. 2002-745938: OF OFFICIAL RECORDS. ASSESSOR'S PARCEL NUMBER: 777-170-006-9 L AUG 01 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT " HIDEAWAY ; OWNERS ASSOCIATION FtECEWP-D, June 28, 2016 AUG 09 2016 Mr. and Mrs. Larry Pisciotta , • a, 5500 E. Quincy Avenue CI.Ty OIC LAQUIRIT@ Englewood, CO 80113 - - COMWIUNITy DFN LOPMENT , Re: Lot 318 at 52581 Via Bellagio + Remodel: Architectural Modifications' Dear Mr. and Mrs. Pisciotta, i ,This correspondence' shall serve as notification that the Hideaway Design Review Committee (DRC) reviewed the architectural modifications .presented by Monarch' Homes at the June 21, 2016 meeting. The modifications were approved as follows: 1. The addition of two, new side yard windows was approved subject to the recessing requirements being met. t 2. The removal of an arch on the home and'the arch removal over the Garage doors was approved: 3. The removal of several corbels throughout the residence was approved. t s 4. The replacement of the entry door at the courtyard wa's•approved. 5.. As a reminder, all windows and doors should match the existing with regard to color, finish and mullion design: ' Thank .you ' for your submittal. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmail.com with any questions. ,R Sincerely, THE HIDEAWAYD SIG REVIEW COMMITTEE • ffild Y: f , r ` 0— Title: Date: cc: Monarch Homes ; DRC File '- y iF r s:,C�'3_:.._•Cir'Z"r.-..�tz--n:... .,;.�.+.+'r. - A. i Pursuant to Cal. Civil Code, airy rejection by the DRC may be appealed to the Board of Directors for the Association. If you Irish to pursue an ' appeal, please contact the Association's property manager directly. y 80955 Avenue 52 La Quinta, CA 92253'•,. P: 760 393-5210 - F: 760 398-5788 f .-CITY OF LQU. I NTA . r . BP No. Exempt(no recycling) HOA Approval , ' Construction,& Demolition Debris Management Plan, Construction and Demolition (C&D) debris is waste material that is produced in the process of - construction, renovation, or demolition of structures. The City of La Quinta requires at least 500;. diversion. Recycling helps to keep reusuable resources out of the landfills and will also reduce disposal costs. KEEP A COPY OF THIS PLAN AT THE WORK SITE SHADED AREAS TO BE COMPLETED, BY THE CITY . Plan Submittal Date Plan Approval Date Project Name / Description Tract Number / APN No. Pisciotta RESIDENCE Job Site Address Project Square Feet / Total Acreage of Project 53-581 Via Bellagio 0 Owner's'Name Owner's Phone Number Mr. & Mrs. Pisciotta '• 760.413.8863 Owner's Mail Address City, State, Zip 53-581 Via BellagioI LA QUINTA, CA. 92253 Project's Name / Company Project Manager's Phone Number_. t MONARCH HOMES DESERT DIVISION, INC. 760.413.8863 Project Manager's Cell Phone Number ' Fax Email 760.413.8863 s City Approval byI Date City Approved I hereby certify that completion, implementation and adherence of the Debris Management Plan ("DMP") for the above named project shall guarantee a minimum of 50% diversion of all materials generated from the first day of the project through the completion of the project in accordance with the reuse and recycling methods identified on the attached worksheet. This DMP is issued in the name of the property owners) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may, obtain a DMP for the owner. However, the DMP is still issued in the name of,the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) shall be kept informed of the progress of the DMP. Violation of this ordinance may include fines and/or incarceration. Owner / Developer / Project Manager Date David Jacobsen - . 8/9/2016 SAVE MONEY, PROTECT THE ENVIRONMENT, ONLY USE LICENSED WASTE & RECYCLING FACILITIES, RECYCLE! Distribution: WHITE - Environmental Programs Coordinator; CANARY - Building Dept; PINK - Permit Holder, GOLD - Burrtec Form: CDDMP-01 Construction & Demolition Debris Management Plan SUMMARY PLAN Tonnage calculations derived from Plan Worksheet are to be placed in Column A below. The Construction Representative will assist you to determine the most practical destinations for these waste materials keeping in mind the City's minimum diversion requirements together with your project's space, time, labor, and budget limitations. Material Category Asphalt/Concrete Asphalt Concrete Brick/Masonry/Tile Brick Masonry block (broken) Tile (root) ' Tile (flooring) Plaster Building Materials (Doors, fixtures, Windows, Plate Glass, cabinets, Other) Cardboard Carpet Drywall, new or used Furniture Landscape Debris Scrap Metal Wood, pallets, clean, unpainted (no pressure treated lumber) Garbage/Trash Other COLUMN TOTALS Diversion Calculation • Column B ••1 ,. 1 11 1 11 1 11 11 1 11 1 11 1 11 1 11 1 11 1 11 111 111 111 111 111 1 11 1 11 1 11 1 11 1 11 111 111 111 111 111 111 111 111 111 111 1 11 1 11 1 11 / 11 1 11 11 1 11 11 1 11 111 11 1 11 11 1 11 1 11' 1 11 1 11 1 11 1 11 1 111 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 /1 1 11 1 11 1 11 1 11 1 /1 1 11 1 11 11 1 11 /1 / 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 11 1 11 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11' 111 111 111 111 111' 1 11 11 1 11 11 1 11 1 11 1 11 1 /1 1 1/ 1 11 111 111 111 111 111, 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 11 1 1/ 1 /1 1 Column B Total 1.00 2 Column C Total 6.00 3 Sum of above 7.00 4 Divide answer 3 by Column A Total 1.17 Your diversion goal for this project 10 116.67% Owner /Developer/ Project Manager agreement of Construction & Debris Plan If Diversion Percentage is less than 50% a Representative will make recommendations to assist you in achieving your project's compliance requirements. (,,4- .� NOTE:Burrte�as is the ONLY Company authorized to collect solid waste (trash) in'8. For information regarding the legal hauling of recycled materials call Mike Veto (760) 340-5901. Distribution: WHITE -Environmental Programs Coordinator; CANARY -Building Dept; PINK -Permit Holder; GOLD-Burrtec Form: CDDMP-01 Y y DIMENSIONS AND SPECIFICATIONS IRON PIPE SIZE (10.1): % inch VENT PIPE SIZE 5 x 8 inch a O measuremm&g m in inches FRAMING DIMENSIONS A 503/0 B 795/8 C 253/16 RECEI've) . JUN 13 20s3 CITY of LA GUMTrA y COMMU q,' DEVa0pM Jm L'P1 „ f Errrptie is aormrrittad to awrtirruausl>reduct imprevanent �eci6aat<aes are std ct m drange witlrwrt online. Uimensiora p CITY Y O F ' LA QUI NTA or this dradmreareapproavmale; read acrd followthe hamirq/dimeruians in the awrrersnsamral supplied with your { "�� ? . &;dre product 1 &#e Comfort Systemshas rruurulachned rale, mJiableheaft systems surae 1W_ We rale prole br mwr WW on BUILDING �OVE15 SAFETY DEPT: 4w�MP baciredbythebestsa/es srrviae arrddrstribu6onme4mrkintltisirdustry Arfveplaaesacmbine -APPROVED °`a�,toa*ra'°gww;�'e owla`bOy-Waa hi°mad"beauryand"m'm"'taa"by FOR CONSTRUCTION Refer to YourMww's A a=] nrmmnrete iastanarirm am/ c fens �nf�.�;,n A016erized Dealer: r . His arlliose is hsilmitifid Umber o1 tie blhsriel idtostry association: „j to tie AISI stadad h: -- 0 lire WWW.e0lpllEi0mI0II.BOm DATE EMPIRE SINCE 1932 911 1reeBarg Aveeee Belleville, It 12220 i01e091Pirece@l0rl.CON 1191 9/15115 fO11TKs0 R720 & R820 Power Vent Indoor Gas Fireplace Installation' Section 1: Product Dimensions 968" Front View [ 2456 ] Top View Elm L�J 891.. 2 [2275] 2 2 .. 158" [ 64 ] [ 384 ] 3.. Side View (� [ 77 ] 214„ 188,. - 1 [ 553 ] [ 460 ] 33 8 " [862] 12.. [39] PK� 5- 8 " Combustion Air Switch Sensor Line [138] :Gas Inlet Figure 1. R720' Fireplace dimensions (Tolerance ± 3] 154„ 5..- [ 387 ] 20 8 [525] XG0772- 150105.3 www.montigo.com Page 7 R7208 R820 Power Vent Indoor Gas Fireplace OMT1160 nst�allation 1088" Front View [ 2761 ] L 0 5" Top View [ 127 ]� 114" m [285] 974" — [2470] 3] 010" [254] [ 387 ] 20 4 " [526] 101 2" [2579] Side View 158" 3 [384] 7 [78] 28.. _T 21 4" 18-L" 7, 338' [553][460] 1 [862] T .o 58" Combustion Air Switch [ 138 ] Sensor Line Gas Inlet Figure 1 a. R820* Fireplace dimensions (Tolerance :t %e'). Page 8 www.montigo.com XG0772 - 150105.3 46IT160 R720 & R820 Power Vent Indoor Gas Fireplace :� �11St1��1t1011N Section 2: Framing Clearances: To ensure the fireplace operates safely, all models must maintain the following clearances: Note: Clearance from top of fireplace to a combustible ceiling within the fireplace enclosure. Unprotected combustiblewallswhich are perpendiculartothefireplace opening must maintain 6" clearance, see figure 20. Frame in the enclosure for the unit with framing materials, see Figure 3. NOTE: When constructing theframed opening, please ensurethere is access to install the gas line when the unit is installed. See Figure 16. Venting Clearance Requirements: Wall framing 14" Min Figure2. Clearances for rear vented installation with elbow. Wall framing lin. Figure 2a. Clearances for top or rear vented installation, straight vent run or with elbow(s). z&WARNING When this appliance is installed directly on ANY combustible materials other than wood flooring (carpet, vinyl, etc), it must be installed on an equivalent wood or metal panel. This material must extend the full width and depth of the appliance. Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. XG0772 - 150105.3 www.montigo.com Page 9 c J d '0O CL Cc Lu 0 CL Q. R M 4D 0/ 13 O0 0 y C R720* 24 24 2 6 3 0 See Section 7 Finishing R820* 24 24 2 6 3 0 around the fireplace Note: Clearance from top of fireplace to a combustible ceiling within the fireplace enclosure. Unprotected combustiblewallswhich are perpendiculartothefireplace opening must maintain 6" clearance, see figure 20. Frame in the enclosure for the unit with framing materials, see Figure 3. NOTE: When constructing theframed opening, please ensurethere is access to install the gas line when the unit is installed. See Figure 16. Venting Clearance Requirements: Wall framing 14" Min Figure2. Clearances for rear vented installation with elbow. Wall framing lin. Figure 2a. Clearances for top or rear vented installation, straight vent run or with elbow(s). z&WARNING When this appliance is installed directly on ANY combustible materials other than wood flooring (carpet, vinyl, etc), it must be installed on an equivalent wood or metal panel. This material must extend the full width and depth of the appliance. Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. XG0772 - 150105.3 www.montigo.com Page 9 R720-& R820 Power Vent Indoor Gas Fireplace 'N 1`11, 34" 38-4 [863] [983] Header Heade Stud Wall Stud Wall Rear Rear 8' 24" [203] 24" 18T1 " [610] Termination [610][463] PVHPL510-300 Mounting Flange _PV HEX510-300 ' <r Termination' Mounting Floor Flange Fireplace Fireplace Floor o .°. Figure 2b. Clearances for straight rear vented installation with Figure 2c. Clearances for straight rear vented installation with PVHEX510-300. PVHFL510-300. ' r Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper _ installation of screens. Raised Installation: Determine the height of the platform based on where you want the bottom edge of the glass to be, see figure l or la for unit dimensions. Maintain minimum ceiling heightshown intable. Build fireplace frame as shown in figure 3. Maximum Minimum Required Platform Height Ceiling Height 24" 8' ,, 48" 10' Drywa orEqu 1g) 3/4' Plywo, Figure 3. Fireplace installation, (Rough Frame -In dimensions). t U is 29" for straight out the back vent run installations. f Page 10 , www.montigo.com XG0772- 150105.3 46ffIC70 R720 & R820 Power Vent Indoor Gas Fireplace Installat�on� ,gg Installing the Fireplace: Place the Fireplace on the platform and install the Vent pipe, and Power Vent module. Next, connect the Gas line, and provide a gas service shut-off valve; according to local gas codes. Before fastening in place line up the front face of the fireplace (top and bottom Figure 3). then secure in place with 1/4"bolts and washers to the platform. 2"C Figure 4. Fireplace installation, (Inlet Gas & Power Vent). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. ice upply Ga Dnnectio XG0772 - 150105.3 www.montigo.com Page 11 R720 & R820 .Power Vent Indoor Gas FireplaceOIITI�sO y4 ... Y'`f Y � Y FT R1,01-1_ .. 5�_ F `_:Installation � Back framing the Fireplace NOTE: Maintain a 1" clearance around the throat (projection at the front of the fireplace that holds the glass door) when installing 2x4s for back framing. Step 1). Cut and install one 2x4 to fit horizontally under the fireplace throat. µ Step 2). Cut and install required quantity of short filler 2x4's to fit vertically under the horizontal piece. .r Step 3). Cut and install four vertical 2x4's. Place 2 on each side of the fireplace throat. Step 4). Join the two steel header pieces to get the required length, see chart below for steel header measurements. Step 6). Install supplied steel header 1" above the throat. Attach steel header to vertical 2x4's as shown in figure 6. Step 6). Cut and install one horizontal 2x4 below the top frame. 2 x 4 Steel header (supplied a Montigo) (horizontal) 2-pcs 2 x 4 (vertical) Both Sides Typ. tx4 2x4 (Vertical) (horizontal) Figure 5. Completed back frame Fireplace installation . Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. 9 13 1" clearance 1" clearance 0 A " Page 12 www.montigo.com XG0772- 150105.3 Supplied Steel Installed Steel Model Header Header Measurements Measurements R720* 80" x 3" - qty 2 95" x 3" R820* 80" x 3" - qty 2 ;107" x 3" Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. 9 13 1" clearance 1" clearance 0 A " Page 12 www.montigo.com XG0772- 150105.3 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/14) rA! Mnowuw oeinwi CERTIFICATE OF INSTALLATION o��nv r w-Mgwa — CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 1 of 15) Project Name: Pisclotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: oweuingnddres:: 53581 Via Bellagio city La Quinta ZIP Code 92253 This compliance document is only applicable to simple alterations that do not require HERS verification for compliance. When HERS verification is required, a CFIR-ALT-01 shall first be registered with a HERS Provider Data Registry. Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CFIR ALT -O5 and CF2R- ALT -05 Compliance Documents. Possible exemptions from duct leakage testing include: less than 40 ft of ducts were added or replaced, • or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CF1R-ALT-02 must be completed and registered with a HERS Provider Data Registry. Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R -value other than 5.8 per inch, or Open Cell Spray Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R -value of 3.6 per inch, shall complete and register a CFIR-ALT-01 with a HERS Provider Data Registry, If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met. Temporary labels shall not be removed before verification by the building inspector. A. GENERAL INFORMATION 01 Project Name: Pisciotta Interior Remodel 02 Date Prepared: 07/12/2016 03 Project Location: 53581 Via Bellagio 04 Building Front Orientation (deg): East 05 CA City: La Quinta 06 Number of Dwelling Units with Additions: 1 07 Zip Code: 92253 08 Fuel Type: gas 09 Climate Zone: CZ 15 10 Total Conditioned Floor Area (ft 2) (Addition): 0 11 Building Type SINGLE RESIDENCE 12 Slab Area (ft2): 0 13 Project Scope: windows and Slider installation CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION )ATE 1 IP BY1!�J CA Building Energy Efficiency Standards - 2013 Residential Compliance ja�►�57 �(��0/ G a �seS:EIVED JUL 2 2016 COMMUNITTY DE ELnRa n mm June 2014 1 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/141 CERTIFICATE OF INSTALLATION VMLIrVRIVW CIVCKV7 VVIVIIVIIJJIVIV CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 2 of 15) Project Name: Pisciotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number. Dwelling Address: 53581 Via Bellagio city La Quinta Zip Code 92253 Insulation The altered components shall comply with all applicable requirements in The Energy Efficiency Standards Sections 110. 7, 110.8,150.0; All joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weather stripped, or otherwise sealed to limit infiltration and exhilaration. B. ROOF/CEILING INSULATION 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer & Brand Framing Material Framing Size & Spacing Insulation Type ESR Number Cavity Insulation R -value Insulation Depth (inches) Above Deck Insulation R -value Below Deck Insulation R -value 1 ATTIC WOOD 2x @24" O.C. R-38 N/A 0.025 12 n/a N/A C. WALL INSULATION 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer & Brand Framing Material Framing Size & Spacing Insulation Type ESR Number Cavity Insulation R value Insulation Depth (inches) Exterior Wall Insulation R -value Interior Wall Insulation R -value 1 EXTERIOR WALLS WOOD 2x6@16"O.0 R-21 N/A 0.065 5.5 R-21 N/A D. MASS INSULATION 01 02 03 04 0S 06 07 08 I.D. Manufacturer &Brand Location Mass Thickness (inches) Furring Strip Type/ Depth (inches) Insulation Type Exterior Insulation R -value Interior Insulation R -value N/A CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification C1=C-CF7R.AI T115.F MavicpA nRH41 CERTIFICATE OF INSTALLATION v CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 3 of 15) Project Name: Piseiotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: Dwelling Address: 53581 Via Bellagio city La Quinta - Zip Code 92253 E. RAISED FLOOR INSULATION 01 02 03 04 05 06 07 08 09 10 1. D. Manufacturer & Brand Framing Material Framing Size & Spacing Insulation Type ESR Number Cavity Insulation R -value Insulation Depth (inches) Exterior Floor Insulation R -value Interior Floor Insulation R -value N/A -F--- -T F. SLAB FLOOR/PERIMETER INSULATION 01 02 03 04 05 06 07 08 1. D. Manufacturer & Brand Floor Type Insulation Type Insulation Depth (inches) Insulation R-Va►ue Vertical Insulation Length (inches) Horizontal Insulation Length (feet) N/A CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA t Prescriptive Residential Alterations That Do Not Require HERS Field Verification eEC-CF2R-ALT-05-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 4 of 15) Project Name: PisClotta Interior Remodel Enforcement Agency: City of La Qulnta Permit Number: owelfingAddress: 53581 Via Bellagio city La Quinta Zip Code 92253 Roofing and Radiant Barrier G. RADIANT BARRIER 01 Brand Name and product number N/A 02 Installation Type 06 L03 Total Attic Area (ft) Roof Pitch H. REQUIRED VENT AREA 01 Combined NFA of installed upper and lower vents (int) N/A 02 Minimum required combined NFA of upper and lower vents (int) 06 03 NFA of installed upper vents (int) Roof Pitch 04 Minimum required NFA of upper vents (in Z) CRRC Listed Aged Solar Reflectance I. (ROOFING PRODUCTS (COOL ROOF) INSTALLATION INFORMATION 01 02 03 04 05 06 07 08 Roof Pitch CRRC Product ID Number Product Type CRRC Listed Aged Solar Reflectance Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI I I - T I I CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA - Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/141 ' CERTIFICATE OF INSTALLATION - - i vvrnvnoawry CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 5 of 15) Project Name: PIsciotta Interior Remodel /1 Enforcement Agency: City Of La QUlnta 03 Permit Number: Dwe1insAddres': 53581 Via Bellagio - city La Quints Lower Vents . - ZIP 92253 J. RADIANT BARRIER AND ATTIC VENTILATION — ADDITIONAL REQUIREMENTS Radiant Barrier OS Radiant barrier must be Installed on all vertical surfaces In the attic Including gable ends. 02 The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408. 03 The product shall meet all requirements for California certified insulation materials [radiant barriers] of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material 04 When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected. Lower Vents . - 05 Lower vents are within one foot of the eave. Upper Vents -Upper .067T vents are within three feet of the ridge Vent Area 07 The NFA of upper vents must be within required NFA range of upper vents - Note: per Exception to R806.2 of the CBC Title 24, Part2, Vol.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than 50%. Part 2 contains additional requirements that must be met if the area is less than 1:150. ' The responsible person's signature on this compliance document affirms that all applicable requirements In this table have been met. K. ROOFING PRODUCTS (COOL ROOF) — ADDITIONAL REQUIREMENTS 01 Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. 02 Liquid field applied coatings must comply with installation criteria from section 110.8(i)4. 03 Mass roof 25 Ib ft2 or greater: Mass roofs are not required to have a cool roof even if the climate zone specifies minimum performance requirements. The responsible person's signature on this compliance document affirms that all applicable requirements In this table have been met. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 J STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification AD CEC-CF2R-ALT-05-E (Revised 06/14) elAl Icr)DAl1A er.im- nr�e seroernwi CERTIFICATE OF INSTALLATION V CF211YALT-05-E Prescriptive Residential Alterations That Do Not Require HERS.Field Verification (Page 6 of 15) Project Name: Piseiotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: Dwelling Address: 53581 Via Bellagio city La Quinta ZIP Code 92253 Fenestration L. FENESTRATION/GLAZING Includes all Windows, Skylights, Greenhouse/Bay Windows, and Glazed Doors 01 02 03 04 05 06 07 08 09 10 11 Tag/ID Manufacturer/ Brand Fenestration Area ft2 Orientation Chromogenic U -factor SHGC Source of U -factor and SHGC Fenestration Type Exterior Shading Devices Describe Comments/Special Features G1 WINDOW 8 NORTH NO 0.32 0.25 NFCR FIXED Insect Screec G2 WINDOW 8 NORTH NO 0.32 0.25 NFCR FIXED Insect Screei G3 SLIDER 88 WEST NO 0.32 0.25 NFCR SLIDER Insect Screec 1 DOOR 45 EAST NO N/A N/A N/A WOOD Insect Scree M. FENESTRATION/GLAZING - ADDITIONAL REQUIREMENTS 01 For existing buildings the U -factor and SHGC values should be the same or better than the required Energy Commission prescriptive requirements. 02 Temporary labels should not be removed until verified by the building inspector. 03 The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification azu CEC:-CF2R-ALT-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 7 of 15) Prosect Name: Pisciotta Interior Remodel EnforcemeMAgenn: City of La Quinta Permit Number: Dwelling Address: 53581 Via Bellagio city La Quinta ZIP Code 92253 Mechanical and Plumbing N. SPACE CONDITIONING (SC) SYSTEMS — HEATING/COOLING (Prescriptive section 150.2(b)) Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CF1R-ALT-05 and CF2R- ALT -05 Compliance Documents. If new space conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CF1R-ALT-01 shall be completed and registered with a HERS Provider Data Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance: ❑ a: space conditioning system was not altered; p b: less than 40 ft of ducts were added or replaced; ❑ c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos; ❑ d: (exempt from duct leakage testing) if: the existing ducts stem was previously tested and passed by a HERS Rater. 01 02 03 04 ' Dwelling Unit Name SC System Identification or Name SC System Location or Area Served Exemption from HERS Verification 0 0 13 0 13 ❑b ❑c 0 13 C3 13 0 13 0 0 0 13 E3 13 13 13 E3 13 13 13 ❑b C3 13 13 0 13 0 13 0 13 0 0 0 0 0 13 0 0 0 0 0 0 0 0 11 11 0 CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification 92 CEG-CF2R-ALT-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 8 of 15) proiectName: PiSCiotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: oweinngAddress: 53581 Via Bellagio city La Quinta Zip Code 92253 O. INSTALLED WATER HEATING SYSTEMS (Section 150.2(b)1G) 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Dwelling Unit Name Water Heating System Identification or Name Water Heating System Location or Area Served Water Heating System Type Water Heater Type # Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insul. R -Value Back -Up Solar Savings Fraction N/A CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/14) CERTIFICATE OF INSTALLATION l.r1LIr V - L1`1 Lw 1 UUVIMISSION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 9 of 15) Project Name: Pisciotta Interior Remodel Enforcement Agency: City of La Quinta 7ermlt Number: Dwe"'ng A°dress:53581 Via Bellagio `I" La Quinta 2fp Code 92253 P. Installed Water Heater Manufacturer Information 01 02 03 Water Heating System ID or Name Manufacturer Model Number N/A CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 10 of 15) Project Name: PISClotta Interior Remodel Enforcement Agency: City of La Qulnta Permit Number: Dwelling Address: 53581 Via Bellagio Ci" La Quinta zipcode 92253 Lighting General Lighting Requirements Additional new lighting, and altered lighting, shall comply with all applicable requirements specified in Section 150.0(k). Kitchen Lighting requirements 150.0(k)1C: The Wattage of permanently installed luminaires should be determined as specified in Section 130.0(c). 150.0(k)1C: In the kitchen, Any electrical boxes finished with a blank cover count as 180 watts of low efficacy lighting. Compliance demonstrated using Method (a) because only high efficacy luminaires have been installed in the kitchen. Compliance demonstrated using Method (b). At least 50% of the installed watts from permanently installed high efficacy. Total A >_ Total B in Installed Wattage Calculation Table (below) Compliance demonstrated with additional low efficacy wattage allowance of EXCEPTION to 150(k)3 EXCEPTION to 150.0(k)3: Additional low efficacy watts may be allowed when all luminaires in the kitchen are controlled by a vacancy sensor or dimmers, and 1. See 150.0(k)2A where high efficacy and low efficacy luminaires must be separately controlled. 2. See 150.0(k)2G where EMCS may be used as a dimmer; Section 150.0(k)2H where FMCS may be used as a vacancy sensor; or, 150.0(k)21 where multi -scene programmable controller may be used as a dimmer. NOTES: Compliance demonstrated using Method (c). Kitchen lighting qualifies for additional low efficacy lighting and as demonstrated in Installed Wattage Calculation Table in Method (b) (above) in addition to Additional Low Efficacy Wattage Calculation Table (below). The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-AI T.05.F 1Rnvicad ORH41 CERTIFICATE OF INSTALLATION %daurvnrvw tNtKtjT UUMMI551ON CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 11 of 15) Project Name: PiSCiotta Interior Remodel Enforcement Agency: City of La QUlnta 05 Pe rmlt Number: Dwelling Address: 53581 Via Bella to 9� "" La Quinta Total High Efficacy (Method B) VP 92253 Q. Installed Kitchen Lighting Compliance In each row below for each dwelling unit in the building, check the box that indicates the method of compliance. If required by the enforcement agency, provide a Kitchen Lighting Requirements Worksheet for each kitchen in the dwelling unit that complies using method b or c. ❑ Method A: Compliance demonstrated using Method (a) - only high efficacy luminaires have been installed in the kitchen. ❑ Method B: At least 50% of installed watts are from permanently installed high efficacy lighting ❑ Method C: Installation qualifies for additional low efficacy lighting allotment ❑ N/A: No kitchen lighting is installed 01 02 03 04 05 Dwelling Unit Name Kitchen Lighting Compliance Method Total High Efficacy (Method B) Total Low Efficacy (Method B) Total Additional Low Efficacy (Method C) 0 0 0 ❑N/A 11 0 0 11 N/A 11 0 0 ❑N/A 11 0 0 ❑N/A 0a 0 0 C3 N/A 13 0 0 ❑N/A 13 0 13 13 N/A 13 E3 C3 ❑N/A 13 13 13 13 N/A 13 0 0 13 N/A 0 13 0 13 N/A 0 0 13 C3 N/A 0 0 13 13 N/A 11 11 0 ❑N/A 0 13 13 ❑N/A CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/14) rnl Mnordlw CERTIFICATE OF INSTALLATION vCRV T VVIVIIVIIJJI VIV CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 12 of 15) Project Name: Pisciotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: Dwelling Address: 53581 Via Bellagio "" La Quinta Zip Code 92253 Kitchen Lighting Requirements Worksheet Dwelling Unit Name: This Table is applicable only if Kitchen Lighting usine Method M or (c) is selected in Table 0 Method b Total Wattage Calculation Watts from Method b Additional Watts Low Efficacy Luminaire Fixture High Low Efficacy Efficacy Total Watts Luminaire Type High Efficacy Watts Low Efficacy Watts High Quantity Efficacy Low Efficacy 1. Insert 50 if house is:5 2.500 square feet; Insert 100 if house is > 2,500 square feet. x = x = x = x = x = x — Complies with method b if Total A > Total B A > B Method (c) Total Additional Low Efficacy Wattage Calculation see footnote Watts from Method b Additional Watts Low Efficacy High Low Efficacy Efficacy Total Low Efficacy Watts Allowed 1. Insert 50 if house is:5 2.500 square feet; Insert 100 if house is > 2,500 square feet. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification is CEG-CF2R-ALT-05-E (Revised 06/14) CALIFORNIA FNFRGV CnMMIQC1nf.! CERTIFICATE OF INSTALLATION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 13 of 15) Pro iectName: PISClotta Interior Remodel Enforcement Agency: City of La Quinta Permit Number: Dwelling Address: 53581 Via Bellagio city La Quinta 21p Code 92253 Pool and Spa R. POOL AND SPA SYSTEM TYPE 01 Pool and Spa System Type S. POOL AND SPA SYSTEMS AND EQUIPMENT REQUIREMENTS (SECTION 110.4(a) and 110.5) 01 Heater has a thermal efficiency that complies with the Appliance Efficiency Regulations. 02 A readily accessible on-off switch is mounted on the outside of the heater, which allows the heater to be shut off without the user adjusting the thermostat setting. 03 A weatherproof plate or card containing instructions for the energy-efficient operation of the pool or spa heater is permanently mounted. 04 No electric resistance heating except for listed package units that have fully insulated enclosures and tight fitting covers that are insulated to at least R-6. Or if documentation is provided that at least 60 % of the annual heating energy is from site solar energy or recovered energy. 05 1 Heating system has no pilot light. Thle responsible person's signature on this compliance document affirms that all applicable requirements In this table have been met. T. POOL AND SPA SYSTEM INSTALLATION REQUIREMENTS (SECTION 130.4(b)) 01 To allow for the future addition of solar heating equipment, at least 36" of pipe is installed between the filter and heater, or dedicated suction and return lines are installed, or built-in or built-up connections for future solar heating are provided. 02 A cover is provided for outdoor pools or spas that have a heat pump or gas heater. 03 Pools stem has directional inlets to adequately mix the pool water 04 Pool system has a time switch that allows the pump to be set or programmed to run during off-peak periods only Thle responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-E (Revised 06/14) Y j CERTIFICATE OF INSTALLATION �,Aurvmimlm tNt KGT WMMISJIVN CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 14 of 15) Project Name: Pisciotta Interior Remodel Enforcement Agency: City of La Quinta DermIt Number: Dwelling Address: 53581 Via Bellagio `I" La Quinta ZIP Code 92253 U. POOL PUMP SIZING AND FLOW RATE SPECIFICATION (SECTION 150.0(p)) 01 The pool pump specified is listed in the CEC database of certified pool pumps. 02 The pool pump flow rate shall not exceed the maximum pump flow rate calculated based on pool sizing in the table below. The return pipe diameter, suction pipe diameter, and filter area shall be at least as large as the required minimums shown in the table. Alternatively, a flow calculation or flow test result shall be provided to demonstrate that the pump flow rate is less than 6 hour filtration turnover, and the return pipe flow rate does not exceed 8 feet per second and that the suction pipe flow rate does not exceed 6 feet per second. 03 An alternative compliance calculation or a flow test result is provided for this pool or spa use (must attach flow calculation or flow test result to this form) 04 The pump is capable of operating at 2 or more speeds (not applicable if pump is less than 1 horsepower). 05 Each auxiliary pool load is served by either a separate pump, or the system is served by a multi -speed pump. 06 Volume of pool (gallons): 07 Filter Type (Cartridge, Sand, DE): 08a Required Min Return Pipe Diameter (inches) 08b 08C Required Min Suction Pipe Diameter (inches) Required Min Filter Area (ft) 08d Required Max Pump Flow (gpm) 09 Return Pipe Diameter (inches). 10 Suction Pipe Diameter (inches). :11 Filter Surface Area (ft). 12 Max Pump Flow Rate (gallons per minute). :13 Measured flow rate return line (feet per second) :14 Measured flow rate suction line (feet per second) 15 Compliance statement U. 03 = Yes, U. 13 <_ U. 08, and U. 14 <_ U. 06 ❑ Yes 13No The responsible person's signature on this compliance document affirms that all applicable requirements In this table have been met. V. POOL SYSTEM PIPING (Section 150.0(p)2) 01 The suction side pipe is straight for at least 4 pipe diameters before entering the pump (See table below for the required straight run lengths for various pipe sizes). 02 All elbows are sweep elbows, or an elbow type that has a pressure drop that is less than the pressure drop of a straight pipe with a length of 30 pipe diameters. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. W. POOL FILTERS AND VALVES (Section 150.0(p)3 and 4) _01 If a filter is used in a pool intended for public use: The size of the filter is at least the size specified in NSF/ANSI 50. 02 1 If a backwash valve is used: The diameter of the backwash valve is at least 2 inches, or the diameter of the return pipe, whichever is greater. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF2R-ALT-05-F (Revised 061141 CERTIFICATE OF INSTALLATION GAurvftNIA tNtKGY COMMISSION CF2R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 15 of 15) ProlectName: PISClotta Interior Remodel Enforcement Agency: City of La QuintaPermltNumber: Documentation Author Company Name: Date Signed: owelMg Address: 53581 Via Bellagio city La Quinta Address: P-0-BOX5083 ZAP Code 92253 I DOCUMENTATION AUTHOR'S DECLARATION STATEMENT certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ALBERTO DAZA ALBERTO DAZA Documentation Author Company Name: Date Signed: DA.ZARCHSTUD20 07/12/16 Address: P-0-BOX5083 CEA/HERS Certification Identification (If applicable): City/State/zip: Phone: LA QUINTA CA.92248 7602853793 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: David Jacobsen Design Monarch Homes Desert Division Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): OWNER Address: 49950 Jefferson street suite #130-134 CSLB License: 457228 City/State/Zlp: Indio Ca 922017604138863 Phone Date Signed: 07/12/16 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 Matt Parisek, P.E. 2201 Francisco Drive #140-45, El Dorado Hills, CA 95762 (916) 939-3525 matt@parisekengineering.com Structural Engineering and Design Services California Registered Civil Engineer C 52996 Date: July 14, 2016 Client: Monarch Homes Desert Division c/o Dave Jacobsen Ph (760) 413-8863 Email davidpjacobsen@aol.com Project: Structural Comments- 1st Cycle Pisciotta Residence 53-581 Via Bellagio, La Quinta, CA c/o Joe Venuti Dear Mr. Venuti; &Qr5201G -0! 91 RECEIVED JUL 29 2016 CITY ORtAIDGMA 'V' BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATES ai BY � �' The following addresses the structural related comments from the building department, and redlines. The list is numbered to correspond to the list from the building department. Additional Comments Section 1. Post and header sizes were already on the plans, and are in the notes at each item, which also describe what's being done at the particular location. 2. Wall elevation provided for master bedroom wall. The revisions to me seem better than what's out there. All they wanted to do was center the fireplace in the room. The existing beam appears to be a drag beam for the hardi panel to the right. Regarding the 9k load, its the load on the beam as if there was no support. Just wanted to make sure the fireplace header worked and wasn't interested in analyzing the configuration to get an exact number. In actuality the beam probably imposes no load on the fireplace header. 3. Reinforcing was added at the new pad footings. Regarding the slab reinforcing, Sladden did not provide any tension, compression or shear forces to design the slab to as far as I can tell, as this is considered as a non-structural residential slab, so what would the purpose of providing a report for the epoxy do as there is not criteria to compare it to or design to. No criteria to say it has to meet. And you can't drill into the edge of a 4" slab and meet any code design criteria anyway. So what to do here? Weld the wire fabric or rebar back together? Use reinf. wire connectors or rebar connectors? I've never seen that on residential non-structural slabs and seems like it would be a hassle for the contractor to run all that down, and for me to find everything as well.. An interesting problem here. And I don't want them to dig out the slab to a lap -splice length that meets the code either as that's not a good idea. I think it's easier to just dig thru the existing reinf. and leave it intact. So that's what I spec'd on the plans. 4. Provided perforated design for existing configuration to show max. forces the existing wall . can hold per code, and then used those forces to design a conventional shear wall in the area where the window was filled in. See new submittal for appropriate signature. i If you have any questions, please contactme. . Sincerely: L4 Matt Parisek, P.E.