13-1041 (AR)_ P.O. BOX 1504 t 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property. Address: APN: Application description Property Zoning: Application valuation: Applicant: 13-00001041- 53472 3-00001041 53472 VIA BELLAGIO 777-170-025- - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 80000 T41,yl BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: EZRALOW MARSHALL 23622 CALABASAS ROAD #200 CALABASAS, CA 91302 Architect or Engineer: Contractor: FEDDERLY & ASSOCIATES 38747 NOPALES ROAD PALM DESERT, CA 92211 (760)773-5205 Lic. No.: 762889 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/10/.13 OCT 10 2013 1LU CITY OF LA QUINTA ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License C ss: 13 o.: 762889 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is �Licens ]� '2 issued. Date: V 1 % Contractor:have and will maintain workers' compensationinsurance, as required by Section 3700 of the Labor 'V— Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EVEREST INS - Policy Number 760000446081 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if Is uld become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or _ 700 of the Labor e, I shal forthwit mply ith those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: tate: Applicant: 101J0 (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAPURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN - improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building c nstruction, and hereby authorize representatives of this co my tproper, o enter upon the above-mentioned propef spectio urpose . Date: Signature (Applicant or Agent): Application Number . . 13-00001041 ----- Structure Information 181SF SITTING ROOM ADDITION/VB/R-3/CL-A ----- Other struct info . . . . . CODE EDITION 2010 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 181-.00 ---------------------------------------------------------------------------- Permit . . . Additional desc . . Permit Fee . . . . Issue Date Expiration Date . ROOM ADDITION 2013 181.61 Plan Check Fee . . .00 Valuation . . . .. 0 4/08/14 Qty Unit Charge Per Extension 1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF 120.12 1.00 61.4900 EA MISC ROOM ADDN, ADDL 500 SF 61.49 ---------------------------------------------------------------------------- Permit . . . Additional desc . . Permit Fee . . . . Issue Date Expiration Date . ELECTRICAL 2013 23.83 4/08/14 Plan Check Fee .00 Valuation 0 Qty Unit Charge Per. _ Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 23.83 ---------=------------------------------------------------------------------ Permit . . . MECHANICAL 2013 Additional desc . Permit Fee . . . . 11.92 Issue Date . . . . Expiration Date . . 4/08/14 Plan Check Fee . Valuation . . . Qty Unit Charge Per Extension 1.00 .11.9200 EA MECH APPL.REP/ALT 11.92 ---------------------------------------------------------------------------- Special Notes and Comments 181SF SITTING ROOM ADDITION OFF KITCHEN AND VERANDA/VB/RES-3/CLASS A -FR . [ENGINEERED] THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF TRELLIS PATIO COVER. 2010 CALIFORNIA BUILDING CODES. October 10, 2013 9:58:42 AM AORTEGA -----------------=---------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 4.00 PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, ROOM ADDITION 185.90 LQPERMIT Application Number . . . . . 13-00001041 -------------------------------------------------------------------7-------- Other Fees . . . . . . . ... PLAN CHECK, MECHANICAL 4.77 STRONG MOTION (SMI) - RES 8.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 217.36 .00 .00 217.36 Plan Check Total .00 .00 .00 .00 Other Fee Total 226.50 .00 .00 226.50 Grand Total 443.86 .00 .00 443.86 LQPERMIT U� f M- Bin # - City of La Quinta Building 8t' Safety Division AUG 0 7 2013 P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 CITY OF LA QUIN �; Building Permit Application and TrackingWNITY DEVELOP Pe Permit # 7j Project Address: a O Owner's Name: A. P. Number: — Legal Description: Contractor: Address: City, ST, Zip: GLlXQ.d2 G la Telephone: - s>?z<?>.'>:<`:"'€>" .. Address: VJ_d_q� bark Project Description: City, ST, Zip: p10-.( Telephone:. .. .........:.......::........... State Lic. # : A-Ulq City Lic. #: Arch., Engr., Designer:l ' Address: 'City, ST Zip:, c(oot1 ne• TeleP ho . ..........:. Construction Type: AoajlOccupancy: State Lic #•9(0 Project type (circle one): : New Repair DemodnAlter Name of Contact Person:Sq. Ft.: #Stories: #Units: I Telephone # of Contact Person: t o° Estimated Value of Project: DM APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. - Reviewed, ready for corrections Plan Check Deposit Truss Cafes. Called Contact Person Plan Check Balance Title 24 Cafes. Plans picked up Construction Flood plain plan Plans resubmitted l Mechanical Grading plan 2nd Review, ready for correctionssu �� lectrical Called Contact Person top! Plumbing Subcontactor List Grant Deed Plans picked up S.M.I. • H.O.A. Approval Plans resubmitted Grading INHOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue flop School Fees Total PeWt Fees aft ab, rr- V3Y�4 MA Ir011612e1y• 04% ; "T ENT 210 r 44r ;0. A - 0 BUILDING ENERGY ANALYSIS REPORT PROJECT: Ezralow Residence-Addition/Alteration 53-472 Via Billagio, The Hideaway La Quinta, Ca 92253 Project Designer: Fedderly Associates 38-747 Nopales Road Palm Desert, Ca 92211 (760) 773-5205 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 CF&C- IN. *41 4' CITY Or'L.KQUINTA BUILDING & SAFETY DEPT. 0 BUI APPROVED lea SFp FOR CONSTRUCTION _ Job Number: 00111 �-O,� 1 6�oi,� DATE "e �� �� `.:. BY /Vj7. Cq 40 1)4 Date: FNT 8/6/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-0 6 70 9:58:13 ID: 1 • • • TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 Room Load Summary 14 Room Heating Peak Loads 15 Room Cooling Peak Loads 18 EnergyPro 5.1 by Energysoft Job Number: ID: User Number: 6712 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type la Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 8/6/2013 Project Address 53-472 Via Billagio, The Hideaway La Qu California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 3,704 Addition 176 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 3,426 Existing Wall Wood Framed R-19 2,210 Existing Slab Unheated Slab -on -Grade None 3,528 Perim = 383' Existing Roof Wood Framed Attic R-30 102 Existing Wall Wood Framed R-21 174 Existing Roof Wood Framed Attic R-30 176 New Wall Wood Framed R-21 344 New Slab Unheated Slab -on -Grade None 176 Perim = 42' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 103.2 0.710 0.60 none none Bug Screen Existing Rear (E) 100.0 0.710 0.60 6.0 none Bug Screen Existing Rear (E) 160.0 0.710 0.60 10.0 none Bug Screen Existing Rear (E) 140.0 0.710 0.60 none none Bug Screen Existing Rear (E) 80.0 0.710 0.60 none none Bug Screen Removed Right (S) 97.4 0.710 0.60 none none Bug Screen Existing Front (W) 152.5 0.710 0.60 none none Bug Screen Existing Left (N) 108.0 0.250 0.39 none none Bug Screen Existing Right (S) 28.0 0.250 0.39 none none Bug Screen Existing Rear (E) 80.0 0.710 0.73 20.0 none Bug Screen New Front (W) 24.0 0.710 0.73 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 3 of 22 • r: • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type ® Single Family ❑ Addition Alone I ❑ Multi Family m Existing+ Addition/Alteration Date 8/6/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. �e—,—erqVP,, 5.1 by EnerqVSoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 4 of 22 r� L • PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R Project Name Building Type m Single Family 0 Addition Alone Date Ezralow Residence -A ddition/Alteration ❑ Multi Family m Existing+ Addition/Alteration 8/6/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 6.36 6.54 -0.18 Space Cooling 121.41 121.15 0.25 Fans 27.08 26.93 0.15 Domestic Hot Water 12.07 12.07 0.00 Pumps 0.00 0.00 0.00 Totals 166.91 166.69 0.22 Percent Better Than Standard: 0.1 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 897 177 Fuel Available at Site: Natural Gas (N) 995 211 Raised Floor Area: 0 (E) 1,024 480 Slab on Grade Area: 3.704 (S) 805 125 Average Ceiling Height: 9.7 Roof 3,704 0 Fenestration Average U -Factor: 0.65 TOTAL: 993 Average SHGC: 0.58 Fenestration/CFA Ratio: 26.8% REMARKS The Hideaway Lot 176 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, /2013 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Feddedy Associates Address 38-747 Nopales Road Name City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-5205 Signed License # Date EnerqvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 5 of 22 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type m Single Family ❑ Addition Alone 11Multi Family m Existing+ Addition/Alteration Date 8/6/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 3,426 0.026 R-38 0 0 Existing 4.2.1-A9 Existing Residence Wall 622 0.074 R-19 0 90 Existing 4.3.1-A5 Existing Residence Wall 346 0.074 R-19 90 90 Existing 4.3.1-A5 Existing Residence Wall 64 0.074 R-19 90 90 Remove 4.3.1-A5 Existing Residence Wall 654 0.074 R-19 1801 90 1 Existing 4.3.1-A5 Existing Residence Wall 589 0.074 R-19 270 90 Existing 4.3.1-A5 Existing Residence Slab 3,426 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 102 0.032 R-30 0 0 Existing 4.2.1-A8 Existing Residence Wall 26 0.069 R-21 0 90 Existing 4.3.1-A6 Existing Residence Wall 122 0.069 R-21 90 90 Existing 4.3.1-A6 Existing Residence Wall 26 0.069 R-21 180 90 Existing 4.3.1-A6 • Existing Residence Slab 102 0.730 None 0 180 Existin 4.4.7-A1 Existing Residence Roof 176 0.032 R-30 0 0 New 4.2.1-A8 Sitting Room Addition Wall 1361 0.069 R-21 0 90 New 4.3.1-A6 Sitting Room Addition Wall 761 0.069 R-21 90 90 New --74-3. 1-A6 Sitting Room Addition Wall 1321 0.069 R-21 1 1 270 90 New 14.3.1-A6 ISitting Room Addition FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 36.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windoi, Existing Residence 2 Window. 16.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windo Existing Residence 3 Window 16.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windo Existing Residence 4 Window 6.6 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Wridot Existing Residence 5 Window 4.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windot Existing Residence 6 Window 4.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windot Existing Residence 7 Window 6.6 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windot Existing Residence 8 Window 4.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Wridot Existing Residence 9 Window 10.0 0.710 Default 0.60 Default 0 Existing Dual Non -Metal Doors & Windot Existing Residence 10 Window 100.0 0.710 Default 0.60 Default 90 Existing Dual Non -Metal Doors & Windot Existing Residence 11 Window 160.0 0.710 Default 0.60 Default 90 Existing Dual Non -Metal Doors & Windot Existing Residence 12 Window 60.0 0.716 Default 0.60 Default 90 Existing Dual Non -Metal Doors & Windot Existing Residence 13 Window 80.0 0.710 Default 0.60 Default 90 Existing Dual Non -Metal Doors & Windot Existing Residence 14 Window 80.0 0.710 Default 0.60 Default 90 Removed Dual Non -Metal Doors & Wndot Existing Residence 15 Window 10.0 0.710 Default 0.60 1 Default 180 Existing Dual Non -Metal Doors & Windol Existing Residence 16 Window 4.0 0.710 Default 0.60 1 Default 180 Existing Dual Non -Metal Doors & Wndoq Existing Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht in Len H t LExt RExt Dist Len H t Dist Len Hat 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen 0.76 10 Bug Screen 0.76 10.0 10.0 6.0 0.1 6.0 6.0 11 Bug Screen 0.76 10.0 16.0 10.0 0.1 10.0 10.0 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 Ener Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 6 of 22 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type m Single Family ❑ Addition Alone Date ❑ Multi Family m Existing+ Addition/Alteration 8/6/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 176 0.730 None 0 180 New 4.4.7-A 1 Sitting Room Addition FENESTRATION SURFACE DETAILS ID Type . Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 18 Window 4.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 19 Window 8.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 20 Window 16.8 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Wndot Existing Residence 21 Window 20.1 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 22 Window 4.5 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windol Existing Residence 23 Window 10.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 24 Window 10.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Windot Existing Residence 25 Window 6.0 0.710 Default 0.60 Default 180 Existing Dual Non -Metal Doors & Wndot Existing Residence 26 Window 30.0 0.710 Default 0.60 Default 270 Existing Dual Non -Metal Doors & Windot Existing Residence 27 Window 28.0 0.710 Default 0.60 Default 270 Existing I Dual Non -Metal Doors & Windo Existing Residence 28 Window 94.5 0.710 Default 0.60 Default 270 Existing I Dual Non -Metal Doors & Windot Existing Residence 29 Window 28.0 0.250 NFRC 0.39 NFRC 0 Existing Loewen Windows Existing Residence 30 Window 28.0 0.250 NFRC 0.39 NFRC 180 Existing Loewen Windows Existing Residence 31 Window 20.01 0.250 1 NFRC 0.39 1 NFRC 0 Existing Loewen Windows Sitting Room Addition 32 Window 20.01 0.250 1 NFRC 0.39 NFRC 0 Existing Loewen Windows I Sitting Room Addition (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS D Exterior Shade Type Window SHGC Hot Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hot Dist Len H t -1 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Buq Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Buq Screen 0.76 26 Bug Screen 0.76 27 Buq Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 IBug Screen 0.76 Ene Pro 5.1 b Ener SoR User Number: 6712 Run Code: 2013-08-06709:58:13 ID: Page 7 of 22 • n CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date $/6/2013 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Type Area Factor cavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 20.0 0.250 NFRC 0.39 NFRC 0 Existing Loewen Windows Sifting Room Addition 34 Window 20.0 0.250 NFRC 0.39 NFRC 0 Existing Loewen Windows Sitting Room Addition 35 Window 80.0 0.710 Default 0.73 Default 90 New Double Metal Clear Sitting Room Addition 36 Window 24.0 0.710 Default 0.73 Default 270 New Double Metal Clear Sitting Room Addition (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len H2!_ LExt RExt Dist Len Hat Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 8.0 8.0 20.0 0.1 20.0 10.0 36 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-08709:58:13 ID: Page 8 of 22 • i CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Ezralow Residence-Addition/Alteration Building Type ❑Single Family ❑ Addition Alone Date ❑ Multi Family ® Existing+ Addition/Alteration $/6/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Existing HVAC Existing 1st Floor 3,426 32,890 2005 2011 Addition 102 918 2011 Sitting Room Addition 176 2,112 Totals 1761 3,5281 01 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 3 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolinq Duct Location R -Value Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Existing DWH 2 Small Gas Kitchen Pipe Ins 43,000 50 0.60 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o u3i Q c System Name Pipe Lencith Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ EnerqyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-06T09:58:13 ID: Page 9 of 22 C� J � 7i MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Ezralow Residence-Addition/Alteration Date 1 8/6/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. _*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: .§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. 1115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and -s a heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of ,.*.recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 50(VA: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned s ace. '§150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 10 of 22 C� J 0 C` J MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Ezralow Residence-Addition/Alteration 1 8/6/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, i in g, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). •-§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant `sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06T09:58:13 ID: Page 11 of 22 C C. MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Ezralow Residence-Addition/Alteration 1 8/6/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters -Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between luminaire housing and ceiling. ,.,the §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined accordin to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. I EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 12 of 22 174 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Ezralow Residence-Addition/Alteration 8/6/2013 System Name Floor Area Existing HVAC 3,704 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 2,902 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output perSystem 75,000 68,848 3,496 1,257 64,772 Total Output Btuh 225,000 0 Output Btuh/s ft 60.7 5,838 4,602 Cooling System 0 0 Output perSystem 44,000 0 0 0 0 Total Output Btuh 132,000 0 3,496 0 Total Output ons 11.0 5,838 4,602 Total Output Btuh/s ft 35.6 Total Output s ftrTon 336.7 1 80,524 73,976 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 4,200 Existing Maytag HVAC 112,318 0 225,000 Airflow cfm/s ft 1.13 Total Adjusted System Output 112,318 (Adjusted for Peak Design conditions) 0 225,000 Airflow cfm/Ton 381.8 Outside Air % 0.0% 0.00 Outside Air cfm/s ft TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 119 °F 119 OF Outside Air 0 cfm Heating Coil Supply Fan 118OF 4,200 cfm ......ROGM_...._ . 69 of 70 OF ..COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 °F 79162 OF 54 / 53 OF 54 / 53 OF Outside Air 0 cfm Cooling Coil Supply Fan 55 / 53 OF 4,200 cfm 40.5% ROOM 79 / 62 OF 78/ 62 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06T09:58:13 /D: Page 13 of 22 s • 0 ROOM LOAD SUMMARY 3,496 1,257 64,772 2,902 68,848 3,496 1,257 64,772 Project Name Ezralow Residence -A ddition/Alteration Date 8/6/2013 System Name Existing HVAC Floor Area 3,704 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Existing Residence Existing 1st Floor 1 2,468 59,732 3,221 2,468 59,732 3,221 1,085 55,595 2011 Addition 1 1 89 1,863 101 89 1,863 101 42 2,260 Sitting Room Addition Sitting Room Addition 1 1 345 7,253 174 345 7,253 174 130 6,918 PAGE TOTAL TOTAL* 2,902 68,848 3,496 1,257 64,772 2,902 68,848 3,496 1,257 64,772 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-08-06T09:58:13 ID: Pae 14 of 22 r� C] 0 ROOM HEATING PEAK LOADS Project Name Ezralow Residence -A ddition/Alteration Date 8/6/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Floor Area 3,426.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT °F X 44 X 44 X 44 X 44 X X X X X X X X X X X X X X X X X X X X X X X X X X X Page Total /60] X AT Btu/hr = 3,919 = 7,195 = 23,527 = 11,499 = = = = = = = = = = = = = = = = = = = = = = = = = = = 46,141 44 = 9,454 R-38 Roof(R.38.2x 12.16) 3,426.0 0.0260 R-19 Wall (W. 19.2x6.16) 2,209.9 0.0740 Dual Non -Metal Doors & Window 753.1 0.7100 Slab -On -Grade perim = 358.0 0.7300 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 3,426 X Area another room 9.60 X 0.368 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 55,595 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 15 of 22 • • • ROOM HEATING PEAK LOADS Project Name Ezralow Residence-Addition/Alteration ROOM INFORMATION DESIGN CONDITIONS Room Name 2011 Addition Time of Peak Floor Area 102.0 ft' Outdoor Dry Bulb Temperature I d D B Ib T rat re 68 OF Date 8/6/2013 Jan 1 AM 26 OF n oor u em e u Conduction Area R-30 Roof(R.30.2x12.16) 102.0 R-21 Wall (W.21.2x6.16) 174.0 Loewen Windows 56.0 Slab -On -Grade perim = 25.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 102 X Schedule Air Sensible Area Fraction U -Value X 0.0320 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr 42 = 137 42 = 504 42 = 588 42 = 767 = = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total 1.996 / 60 X 42 = 264 AT X 0.0690 X 0.2500 X X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.386 Ceiling Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 2,260 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-08-06T09:58:13 ID: Page 16 of 22 • • C7 ROOM HEATING PEAK LOADS Project Name Ezralow Residence -A ddition/Alteration Date 8/6/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Sitting Room Addition Floor Area 176.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area U -Value AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-30 Roof(R.30.2x12.16) 176.0 X 0.0320 X 42 237 R-21 Wall (W.21.2x6.16) 344.0 X X 0.0690 X X 42 997 Loewen Windows 80.0 0.2500 42 840 Double Metal Clear 104.0 X 0.7100 X 42 3,101 Slab -On -Grade perim = 42.0 X X 0.7300 X X 42 1,288 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 176 X Area to another room 12.00 X 0.290 Ceiling Height ACH Page Total /60] X AT 6,462 = 456 TOTAL HOURLY HEAT LOSS FOR ROOM 6,918 EnergyPro 5.1 by EnergySo(t User Number.- 6712 RunCode: 2013-08-06709:58:13 ID: Page 17 of 22 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X GLF + + + + + + + + + Project Name X X X X X X X X X GLF r Date Ezralow Residence-Addition/Alteration 36.5 36.0 1 8/6/2013 ROOM INFORMATION 36.5 DESIGN CONDITIONS 36.5 583 0.0 Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 583 112 OF Floor Area 3,426.0 ft' Outdoor Wet Bulb Temperature 241 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 146 0.0 34 OF 4.0 36.5 146 0.0 36.5 6.6 Opaque Surfaces Orientation Area U -Factor 241 CLTD' Btu/hr R-38 Roof(R.38.2x12.16) 36.5 146 (N) 36.5 3,426.0 X 0.0260 X 56.0 = 4,988 R-19 Wall (W. 19.2x6.16) (N) 621.8 X 0.0740 X 23.0 = 1,058 R-19 Wall (W. 19.2x6.16) (E) 346.0 X 0.0740 X 33.0 = 845 R-19 Wall (W. 19.2x6.16) (S) 653.6 X 0.0740 X 26.0 = 1,258 R-19 Wall (W. 19.2x6.16) (W) 588.5 X 0.0740 X 33.0 = 1,437 X X = X X = X X = X J X = Page Total 1 9,586 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanastratinn Window Window Window Window Window Window Window Window Window Gain Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = Btu/hr 0.0 36.5 36.0 36.5 1,313 0.0 36.5 16.0 36.5 583 0.0 36.5 16.0 36.5 583 0.0 36.5 6.6 36.5 241 0.0 36.5 4.0 36.5 146 0.0 36.5 4.0 36.5 146 0.0 36.5 6.6 36.5 241 0.0 36.5 4.0 36.5 146 0.0 36.5 10.0 36.5 365 Page Total 3, 763 4.0 Occupants X 230 Btuh/occ. = 920 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 212.14 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 59,7] Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 212.14 X 0.00276 = 2,421 Air Sensible CFM ELA AW R ROOM • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ezralow Residence-Addition/Alteration 1 8/6/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 3,426.0 It' Outdoor Wet Bulb Temperature 78 0 Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. I. Coolino Load Temperature Difference (CLTD) I Fanoctratinn Window Window Window Window Window Window Window Window Window Ariantatinn (E) (E) (E) (E) (S) (S) (S) (S) (S) Shaded Area GLF 47.0 X 36.5 126.4 X 36.5 0.0 X 36.5 0.0 X 36.5 0.0 X 36.5 0.0 X 36.5 0.0 X 36.5 0.0 X 36.5 0.0 X 36.5 + + + + + + + + + Unshaded Area X X X X X X X X X GLF 72.1 = 53.0 33.6 72.1 = = 60.0 72.1 80.0 72.1 = 10.0 36.6 = 4.0 36.6 = = 4.0 36.6 4.0 36.6 = 36.6 = Page Total 8.0 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Btu/hr Btu/hr 5,534 7,031 4,325 5,767 366 146 146 146 293 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 1 Btu = 1,600 Infiltration: 1.064 X 0.87 X 212.14 X 34 = 6,647 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 59,732 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 212.14 X 0.00276 = 2,421 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3 221 0 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Ezralow Residence-Addition/Alteration 8/6/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 3,426.0 ft' I Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Panaatrntinn Window Window Window Window Window Window Window Window Window Orientation Btu/hr 171 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = Btu/hr 0.0 36.5 16.8 36.6 615 0.0 36.5 20.1 36.6 736 0.0 36.5 4.5 36.6 165 0.0 36.5 10.0 36.6 366 0.0 36.5 10.0 36.6 366 0.0 36.5 6.0 36.6 220 0.0 36.5 30.0 72.1 2,163 0.0 36.5 28.0 72.1 Z018 0.0 36.5 94.5 72.1 6,812 Page Total 13,461 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 1Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 212.14 X 34 = 6,647 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 59,732 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 212.14 X 0.00276 = 2.421 Air Sensible CFM ELA AW HEAT GAIN FOR • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Namee 781612013 Ezralow Residence-Addition/Alteration ROOM INFORMATION DESIGN CONDITIONS Room Name 2011 Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 102.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-30 Roof(R.30.2x 12.16) (N) 102.0 X 0.0320 X 56.0 = 183 R-21 Wall (W.21.2x6.16) (N) 26.0 X 0.0690 X 23.0 = 41 R-21 Wall (W.21.2x6.16) (E) 122.0 X 0.0690 X 33.0 = 278 R-21 Wall (W.21.2x6.16) (S) 26.0 X 0.0690 X 26.0 = 47 X X = X X = X X = X X = X X = Page Total 548 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 19.5 + 28.0 X 19.5 = 545 Window (S) 0.0 X 19.5 + 28.0 X 19.6 = 548 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 1,093 Internal Gain Btu/hr- Btu/hr Occupants ants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 6.32 X 37 = 222 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1,863 Latent Gain Btu/hr Occupants 0.0 Occupants X 200 Btuh/occ. = 0 Infiltration: 4,771 X 0.89 X 6.32 X 0.00376 = 101 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 101 EnergyPro 5.1 bv EnerovSoft User Number., 6712 RunCode: 2013-08-06709:58:13 ID: Pace 21 of 22 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ezralow Residence-Addition/Alteration 1 8/6/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Sitting Room Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 176.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-30 Roof(R.30.2x12.16) (N) 176.0 X 0.0320 X 56.0 = 315 R-21 Wall (W.21.2x6.16) (N) 136.0 X 0.0690 X 23.0 = 216 R-21 Wall (W.21.2x6.16) (E) 76.0 X 0.0690 X 33.0 = 173 R-21 Wall (W.21.2x6.16) (W) 132.0 X 0.0690 X 33.0 = 301 X X = X X = X X = X X = X J X = Page Total 1,005 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 19.5 + 20.0 X 19.5 = 389 Window (N) 0.0 X 19.5 + 20.0 X 19.5 = 389 Window (N) 0.0 X 19.5 + 20.0 X 19.5 = 389 Window (N) 0.0 X 19.5 + 20.0 X 19.5 = 389 Window I (E) 80.01 X 41.3 + 0.0 X 84.6 = 3,303 Window (tom 23.7 X 41.3 + 0.3 X 84.6 = 1,004 X + X = X + X = X + X = Page Total 5,865 Internal Gain Btu/hr-Occupants 0.0 Occupants X 230 Btuh/occ. = Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.89 X 10.90 X 37 = 383 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,253 Latent Gain Btu/hr Occupants77] 0.0 Occupants X 2001 Btuh/occ. = o Infiltration: 4,771 X 0.89 X 10.90 X 0.00376 = 174 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 174 Ene Pro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2013.08-06709:58:13 ID: Pa a 22 of 22