13-1041 (AR)_ P.O. BOX 1504
t 78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property. Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
13-00001041-
53472
3-00001041
53472 VIA BELLAGIO
777-170-025- -
ADDITION - RESIDENTIAL
LOW DENSITY RESIDENTIAL
80000
T41,yl
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
EZRALOW MARSHALL
23622 CALABASAS ROAD #200
CALABASAS, CA 91302
Architect or Engineer:
Contractor:
FEDDERLY & ASSOCIATES
38747 NOPALES ROAD
PALM DESERT, CA 92211
(760)773-5205
Lic. No.: 762889
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/10/.13
OCT 10 2013 1LU
CITY OF LA QUINTA
-------------------------------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License C ss: 13 o.: 762889
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
�Licens
]� '2
issued.
Date: V 1 % Contractor:have
and will maintain workers' compensationinsurance, as required by Section 3700 of the Labor
'V—
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier EVEREST INS - Policy Number 760000446081
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if Is uld become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or _
700 of the Labor e, I shal forthwit mply ith those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
tate: Applicant:
101J0
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAPURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN -
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed
pursuant to the Contractors' State License Law.).
(_ 1 1 am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building c nstruction, and hereby authorize representatives
of this co my tproper, o enter upon the above-mentioned propef spectio urpose .
Date: Signature (Applicant or Agent):
Application Number . . 13-00001041
----- Structure Information 181SF SITTING ROOM ADDITION/VB/R-3/CL-A -----
Other struct info . . . . . CODE EDITION 2010
FLOOD ZONE NO
1ST FLOOR SQUARE FOOTAGE 181-.00
----------------------------------------------------------------------------
Permit . . .
Additional desc . .
Permit Fee . . . .
Issue Date
Expiration Date .
ROOM ADDITION 2013
181.61 Plan Check Fee . . .00
Valuation . . . .. 0
4/08/14
Qty Unit Charge Per Extension
1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF 120.12
1.00 61.4900 EA MISC ROOM ADDN, ADDL 500 SF 61.49
----------------------------------------------------------------------------
Permit . . .
Additional desc . .
Permit Fee . . . .
Issue Date
Expiration Date .
ELECTRICAL 2013
23.83
4/08/14
Plan Check Fee .00
Valuation 0
Qty Unit Charge Per. _ Extension
1.00 23.8300 LS ELEC DEVICES, FIRST 20 23.83
---------=------------------------------------------------------------------
Permit . . . MECHANICAL 2013
Additional desc .
Permit Fee . . . . 11.92
Issue Date . . . .
Expiration Date . . 4/08/14
Plan Check Fee .
Valuation . . .
Qty Unit Charge Per Extension
1.00 .11.9200 EA MECH APPL.REP/ALT 11.92
----------------------------------------------------------------------------
Special Notes and Comments
181SF SITTING ROOM ADDITION OFF KITCHEN
AND VERANDA/VB/RES-3/CLASS A -FR .
[ENGINEERED] THIS PERMIT DOES NOT
INCLUDE REPLACEMENT OF TRELLIS PATIO
COVER. 2010 CALIFORNIA BUILDING CODES.
October 10, 2013 9:58:42 AM AORTEGA
-----------------=----------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 4.00
PLAN CHECK, ELECTRICAL 23.83
PLAN CHECK, ROOM ADDITION 185.90
LQPERMIT
Application Number . . . . . 13-00001041
-------------------------------------------------------------------7--------
Other Fees . . .
. . . . ...
PLAN CHECK,
MECHANICAL
4.77
STRONG MOTION (SMI) - RES
8.00
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
217.36
.00
.00
217.36
Plan Check Total
.00
.00
.00
.00
Other Fee Total
226.50
.00
.00
226.50
Grand Total
443.86
.00
.00
443.86
LQPERMIT
U�
f M-
Bin #
-
City of La Quinta
Building 8t' Safety Division AUG 0 7 2013
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012 CITY OF LA QUIN
�; Building Permit Application and TrackingWNITY DEVELOP
Pe
Permit #
7j
Project Address: a O
Owner's Name:
A. P. Number: —
Legal Description:
Contractor:
Address:
City, ST, Zip: GLlXQ.d2 G la
Telephone: - s>?z<?>.'>:<`:"'€>"
..
Address: VJ_d_q� bark
Project Description:
City, ST, Zip:
p10-.(
Telephone:.
.. .........:.......::...........
State Lic. # : A-Ulq
City Lic. #:
Arch., Engr., Designer:l '
Address:
'City, ST Zip:,
c(oot1
ne•
TeleP ho .
..........:.
Construction Type: AoajlOccupancy:
State Lic #•9(0
Project type (circle one): : New Repair DemodnAlter
Name of Contact Person:Sq.
Ft.:
#Stories:
#Units: I
Telephone # of Contact Person: t
o°
Estimated Value of Project: DM
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING PERMIT FEES
Plan Sets
Plan Check submitted Item Amount
Structural Cafes.
-
Reviewed, ready for corrections Plan Check Deposit
Truss Cafes.
Called Contact Person Plan Check Balance
Title 24 Cafes.
Plans picked up Construction
Flood plain plan
Plans resubmitted l Mechanical
Grading plan
2nd Review, ready for correctionssu �� lectrical
Called Contact Person top! Plumbing
Subcontactor List
Grant Deed
Plans picked up S.M.I. •
H.O.A. Approval
Plans resubmitted Grading
INHOUSE:-
'"' Review, ready for corrections/issue Developer Impact Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr
Date of permit issue flop
School Fees
Total PeWt Fees
aft
ab, rr- V3Y�4
MA
Ir011612e1y• 04% ;
"T
ENT
210
r
44r
;0.
A -
0
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Ezralow Residence-Addition/Alteration
53-472 Via Billagio, The Hideaway
La Quinta, Ca 92253
Project Designer:
Fedderly Associates
38-747 Nopales Road
Palm Desert, Ca 92211
(760) 773-5205
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
CF&C- IN. *41 4'
CITY Or'L.KQUINTA
BUILDING & SAFETY DEPT. 0
BUI
APPROVED
lea SFp
FOR CONSTRUCTION _ Job Number: 00111 �-O,� 1 6�oi,�
DATE "e �� �� `.:. BY /Vj7. Cq
40
1)4
Date: FNT
8/6/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-0 6 70 9:58:13 ID: 1
•
•
•
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 10
HVAC System Heating and Cooling Loads Summary 13
Room Load Summary 14
Room Heating Peak Loads 15
Room Cooling Peak Loads 18
EnergyPro 5.1 by Energysoft Job Number: ID: User Number: 6712
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type la Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/6/2013
Project Address
53-472 Via Billagio, The Hideaway La Qu
California Energy Climate Zone
CA Climate Zone 15
I Total Cond. Floor Area
3,704
Addition
176
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 3,426 Existing
Wall Wood Framed R-19 2,210 Existing
Slab Unheated Slab -on -Grade
None 3,528 Perim = 383' Existing
Roof Wood Framed Attic
R-30 102 Existing
Wall Wood Framed
R-21 174 Existing
Roof Wood Framed Attic R-30 176 New
Wall Wood Framed
R-21 344 New
Slab Unheated Slab -on -Grade
None 176 Perim = 42' New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Left (N) 103.2 0.710
0.60 none none Bug Screen Existing
Rear (E) 100.0 0.710
0.60 6.0 none Bug Screen Existing
Rear (E) 160.0 0.710
0.60 10.0 none Bug Screen Existing
Rear (E) 140.0 0.710
0.60 none none Bug Screen Existing
Rear (E) 80.0 0.710
0.60 none none Bug Screen Removed
Right (S) 97.4 0.710
0.60 none none Bug Screen Existing
Front (W) 152.5 0.710
0.60 none none Bug Screen
Existing
Left (N) 108.0 0.250
0.39 none none Bug Screen
Existing
Right (S) 28.0 0.250
0.39 none none Bug Screen
Existing
Rear (E) 80.0 0.710
0.73 20.0 none Bug Screen
New
Front (W) 24.0 0.710
0.73 10.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
3 Central Furnace 80% AFUE
Split Air Conditioner 15.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Existing HVAC Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number: 6712
RunCode: 2013-08-06709:58:13 ID:
Page 3 of 22
•
r:
•
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type ® Single Family ❑ Addition Alone
I ❑ Multi Family m Existing+ Addition/Alteration
Date
8/6/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
�e—,—erqVP,, 5.1 by EnerqVSoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 4 of 22
r�
L
•
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family 0 Addition Alone
Date
Ezralow Residence -A ddition/Alteration
❑ Multi Family m Existing+ Addition/Alteration
8/6/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 6.36 6.54 -0.18
Space Cooling 121.41 121.15 0.25
Fans 27.08 26.93 0.15
Domestic Hot Water 12.07 12.07 0.00
Pumps 0.00 0.00 0.00
Totals 166.91 166.69 0.22
Percent Better Than Standard: 0.1
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (w) 897 177
Fuel Available at Site: Natural Gas (N) 995 211
Raised Floor Area: 0 (E) 1,024 480
Slab on Grade Area: 3.704 (S) 805 125
Average Ceiling Height: 9.7 Roof 3,704 0
Fenestration Average U -Factor: 0.65 TOTAL: 993
Average SHGC: 0.58 Fenestration/CFA Ratio: 26.8%
REMARKS
The Hideaway Lot 176
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
/2013
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Feddedy Associates
Address 38-747 Nopales Road Name
City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-5205 Signed License # Date
EnerqvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 5 of 22
•
•
•
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type m Single Family ❑ Addition Alone
11Multi Family m Existing+ Addition/Alteration
Date
8/6/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
3,426
0.026 R-38
0
0 Existing 4.2.1-A9 Existing Residence
Wall
622
0.074 R-19
0
90 Existing 4.3.1-A5 Existing Residence
Wall
346
0.074 R-19
90
90 Existing 4.3.1-A5 Existing Residence
Wall
64
0.074 R-19
90
90 Remove 4.3.1-A5 Existing Residence
Wall
654
0.074 R-19
1801
90 1 Existing 4.3.1-A5 Existing Residence
Wall
589
0.074 R-19
270
90 Existing 4.3.1-A5 Existing Residence
Slab
3,426
0.730 None
0
180 Existing 4.4.7-A1 Existing Residence
Roof
102
0.032 R-30
0
0 Existing 4.2.1-A8 Existing Residence
Wall
26
0.069 R-21
0
90 Existing 4.3.1-A6 Existing Residence
Wall
122
0.069 R-21
90
90 Existing 4.3.1-A6 Existing Residence
Wall
26
0.069 R-21
180
90 Existing 4.3.1-A6 • Existing Residence
Slab
102
0.730 None
0
180 Existin 4.4.7-A1 Existing Residence
Roof
176
0.032 R-30
0
0 New 4.2.1-A8 Sitting Room Addition
Wall
1361
0.069 R-21
0
90 New 4.3.1-A6 Sitting Room Addition
Wall
761
0.069 R-21
90
90 New --74-3. 1-A6 Sitting Room Addition
Wall
1321
0.069 R-21 1
1
270
90 New 14.3.1-A6 ISitting Room Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type Location/Comments
1
Window
36.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windoi, Existing Residence
2
Window.
16.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windo Existing Residence
3
Window
16.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windo Existing Residence
4
Window
6.6 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Wridot Existing Residence
5
Window
4.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windot Existing Residence
6
Window
4.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windot Existing Residence
7
Window
6.6 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windot Existing Residence
8
Window
4.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Wridot Existing Residence
9
Window
10.0 0.710 Default
0.60 Default
0 Existing
Dual Non -Metal Doors & Windot Existing Residence
10
Window
100.0 0.710 Default
0.60 Default
90 Existing
Dual Non -Metal Doors & Windot Existing Residence
11
Window
160.0 0.710 Default
0.60 Default
90 Existing
Dual Non -Metal Doors & Windot Existing Residence
12
Window
60.0 0.716 Default
0.60 Default
90 Existing
Dual Non -Metal Doors & Windot Existing Residence
13
Window
80.0 0.710 Default
0.60 Default
90 Existing
Dual Non -Metal Doors & Windot Existing Residence
14
Window
80.0 0.710 Default
0.60 Default
90 Removed Dual Non -Metal Doors & Wndot Existing Residence
15
Window
10.0 0.710 Default
0.60 1 Default
180 Existing
Dual Non -Metal Doors & Windol Existing Residence
16
Window
4.0 0.710 Default
0.60 1 Default
180 Existing
Dual Non -Metal Doors & Wndoq Existing Residence
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht in
Len H t LExt RExt Dist Len H t Dist Len Hat
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bu Screen
0.76
10
Bug Screen
0.76
10.0 10.0
6.0 0.1
6.0 6.0
11
Bug Screen
0.76
10.0 16.0
10.0 0.1 10.0 10.0
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 6 of 22
•
•
•
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type m Single Family ❑ Addition Alone Date
❑ Multi Family m Existing+ Addition/Alteration 8/6/2013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
176 0.730 None
0
180 New 4.4.7-A 1 Sitting Room Addition
FENESTRATION SURFACE DETAILS
ID
Type . Area
LI -Factor' SHGC
Azm Status
Glazing Type Location/Comments
17
Window 4.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
18
Window 4.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
19
Window 8.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
20
Window 16.8
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Wndot Existing Residence
21
Window 20.1
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
22
Window 4.5
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windol Existing Residence
23
Window 10.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
24
Window 10.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Windot Existing Residence
25
Window 6.0
0.710 Default 0.60 Default
180 Existing
Dual Non -Metal Doors & Wndot Existing Residence
26
Window 30.0
0.710 Default 0.60 Default
270 Existing
Dual Non -Metal Doors & Windot Existing Residence
27
Window 28.0
0.710 Default 0.60 Default
270 Existing
I Dual Non -Metal Doors & Windo Existing Residence
28
Window 94.5
0.710 Default 0.60 Default
270 Existing
I Dual Non -Metal Doors & Windot Existing Residence
29
Window 28.0
0.250 NFRC 0.39 NFRC
0 Existing
Loewen Windows Existing Residence
30
Window 28.0
0.250 NFRC 0.39 NFRC
180 Existing
Loewen Windows Existing Residence
31
Window 20.01
0.250 1 NFRC 0.39 1 NFRC
0 Existing
Loewen Windows Sitting Room Addition
32
Window 20.01
0.250 1 NFRC 0.39 NFRC
0 Existing
Loewen Windows I Sitting Room Addition
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
D
Exterior Shade Type
Window
SHGC Hot Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hot Dist Len H t
-1
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Buq Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Buq Screen
0.76
26
Bug Screen
0.76
27
Buq Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
IBug Screen
0.76
Ene
Pro 5.1 b Ener SoR User Number: 6712 Run Code: 2013-08-06709:58:13 ID: Page 7 of 22
•
n
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
$/6/2013
OPAQUE SURFACE DETAILS
Surface U Insulation Joint Appendix
Type Area Factor cavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments
33 Window 20.0 0.250 NFRC 0.39 NFRC 0 Existing Loewen Windows Sifting Room Addition
34 Window 20.0 0.250 NFRC 0.39 NFRC 0 Existing Loewen Windows Sitting Room Addition
35 Window 80.0 0.710 Default 0.73 Default 90 New Double Metal Clear Sitting Room Addition
36 Window 24.0 0.710 Default 0.73 Default 270 New Double Metal Clear Sitting Room Addition
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Ri ht Fin
ID Exterior Shade Type SHGC H t Wd Len H2!_ LExt RExt Dist Len Hat Dist Len H t
33 Bug Screen 0.76
34 Bug Screen 0.76
35 Bug Screen 0.76 8.0 8.0 20.0 0.1 20.0 10.0
36 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0
Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-08-08709:58:13 ID: Page 8 of 22
•
i
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5)
CF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Building Type ❑Single Family ❑ Addition Alone Date
❑ Multi Family ® Existing+ Addition/Alteration $/6/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
Existing HVAC Existing 1st Floor
3,426
32,890 2005
2011 Addition
102
918 2011
Sitting Room Addition
176
2,112
Totals 1761 3,5281 01 0
HVAC SYSTEMS
System Name Ot . Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Existing HVAC 3 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Coolinq Duct Location R -Value
Ducts
Tested? Status
Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Existing DWH
2
Small Gas
Kitchen Pipe Ins
43,000
50
0.60 n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
u3i
Q c
System Name
Pipe
Lencith
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
EnerqyPro 5.1 by Ener Soft User Number: 6712
RunCode: 2013-08-06T09:58:13 ID:
Page 9 of 22
C�
J
� 7i
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Ezralow Residence-Addition/Alteration
Date
1 8/6/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
_*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
.§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
1115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
-s a heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
,.*.recirculatinq sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 50(VA: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned s ace.
'§150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 10 of 22
C�
J
0
C`
J
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Ezralow Residence-Addition/Alteration
1 8/6/2013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, i in g, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
•-§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
`sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06T09:58:13 ID: Page 11 of 22
C
C.
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Ezralow Residence-Addition/Alteration
1 8/6/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
-Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
luminaire housing and ceiling.
,.,the
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined accordin to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
I
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 12 of 22
174
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Ezralow Residence-Addition/Alteration
8/6/2013
System Name
Floor Area
Existing HVAC
3,704
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
CFM
Total Room Loads 2,902
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent I CFM
Sensible
Output perSystem 75,000
68,848
3,496 1,257
64,772
Total Output Btuh 225,000
0
Output Btuh/s ft 60.7
5,838
4,602
Cooling System
0
0
Output perSystem 44,000
0
0 0
0
Total Output Btuh 132,000
0
3,496
0
Total Output ons 11.0
5,838
4,602
Total Output Btuh/s ft 35.6
Total Output s ftrTon 336.7
1 80,524
73,976
Air System
CFM perSystem
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
4,200
Existing Maytag HVAC 112,318
0
225,000
Airflow cfm/s ft
1.13
Total Adjusted System Output 112,318
(Adjusted for Peak Design conditions)
0 225,000
Airflow cfm/Ton 381.8
Outside Air % 0.0%
0.00
Outside Air cfm/s ft
TIME OF SYSTEM PEAK
Aug 3 PM I Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
69 OF 119 °F 119 OF
Outside Air
0 cfm
Heating Coil Supply Fan
118OF
4,200 cfm
......ROGM_...._ .
69 of
70 OF
..COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 °F
79162 OF 54 / 53 OF 54 / 53 OF
Outside Air
0 cfm
Cooling Coil Supply Fan
55 / 53 OF
4,200 cfm
40.5%
ROOM
79 / 62 OF
78/ 62 OF
EnergyPro 5.1 by EnergySoft
User Number: 6712 RunCode: 2013-08-06T09:58:13 /D:
Page 13 of 22
s
•
0
ROOM LOAD SUMMARY
3,496
1,257
64,772
2,902 68,848
3,496
1,257
64,772
Project Name
Ezralow Residence -A ddition/Alteration
Date
8/6/2013
System Name
Existing HVAC
Floor Area
3,704
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM
Sensible
Latent
CFM
Sensible Latent
CFM Sensible
Existing Residence Existing 1st Floor
1 2,468
59,732
3,221
2,468
59,732
3,221
1,085 55,595
2011 Addition
1 1 89
1,863
101
89
1,863
101
42 2,260
Sitting Room Addition Sitting Room Addition
1 1 345
7,253
174
345
7,253
174
130 6,918
PAGE TOTAL
TOTAL*
2,902 68,848
3,496
1,257
64,772
2,902 68,848
3,496
1,257
64,772
Total includes ventilation load for zonal systems.
EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-08-06T09:58:13 ID: Pae 14 of 22
r�
C]
0
ROOM HEATING PEAK LOADS
Project Name
Ezralow Residence -A ddition/Alteration
Date
8/6/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing 1st Floor
Floor Area 3,426.0 ft2
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
AT °F
X 44
X 44
X 44
X 44
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page Total
/60] X
AT
Btu/hr
= 3,919
= 7,195
= 23,527
= 11,499
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46,141
44 = 9,454
R-38 Roof(R.38.2x 12.16)
3,426.0
0.0260
R-19 Wall (W. 19.2x6.16)
2,209.9
0.0740
Dual Non -Metal Doors & Window
753.1
0.7100
Slab -On -Grade
perim = 358.0
0.7300
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
1.064 X 3,426 X
Area
another room
9.60 X 0.368
Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 55,595
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-06709:58:13 ID: Page 15 of 22
•
•
•
ROOM HEATING PEAK LOADS
Project Name
Ezralow Residence-Addition/Alteration
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2011 Addition Time of Peak
Floor Area 102.0 ft' Outdoor Dry Bulb Temperature
I d D B Ib T rat re 68 OF
Date
8/6/2013
Jan 1 AM
26 OF
n oor u em e u
Conduction Area
R-30 Roof(R.30.2x12.16) 102.0
R-21 Wall (W.21.2x6.16) 174.0
Loewen Windows 56.0
Slab -On -Grade perim = 25.0
Items shown with an asterisk (') denote conduction through an interior surface
Infiltration:[ 1.00 X 1.064 X 102 X
Schedule Air Sensible Area
Fraction
U -Value
X 0.0320
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F Btu/hr
42 = 137
42 = 504
42 = 588
42 = 767
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 1.996
/ 60 X 42 = 264
AT
X
0.0690
X
0.2500
X
X
0.7300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
9.00 X 0.386
Ceiling Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 2,260
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-08-06T09:58:13 ID: Page 16 of 22
•
•
C7
ROOM HEATING PEAK LOADS
Project Name
Ezralow Residence -A ddition/Alteration
Date
8/6/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Sitting Room Addition
Floor Area 176.0 ft'
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.064
Area
U -Value
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
42
Btu/hr
R-30 Roof(R.30.2x12.16)
176.0
X
0.0320
X
42
237
R-21 Wall (W.21.2x6.16)
344.0
X
X
0.0690
X
X
42
997
Loewen Windows
80.0
0.2500
42
840
Double Metal Clear
104.0
X
0.7100
X
42
3,101
Slab -On -Grade
perim = 42.0
X
X
0.7300
X
X
42
1,288
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 176 X
Area
to another room
12.00 X 0.290
Ceiling Height ACH
Page Total
/60] X
AT
6,462
= 456
TOTAL HOURLY HEAT LOSS FOR ROOM 6,918
EnergyPro 5.1 by EnergySo(t User Number.- 6712 RunCode: 2013-08-06709:58:13 ID: Page 17 of 22
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Project Name
X
X
X
X
X
X
X
X
X
GLF
r
Date
Ezralow Residence-Addition/Alteration
36.5
36.0
1
8/6/2013
ROOM INFORMATION
36.5
DESIGN CONDITIONS
36.5
583
0.0
Room Name
Existing 1st Floor
Outdoor Dry Bulb Temperature
583
112 OF
Floor Area
3,426.0 ft'
Outdoor Wet Bulb Temperature
241
78 OF
Indoor Dry Bulb Temperature
78 OF
Outdoor Daily Range:
146
0.0
34 OF
4.0
36.5
146
0.0
36.5
6.6
Opaque Surfaces Orientation Area U -Factor
241
CLTD'
Btu/hr
R-38 Roof(R.38.2x12.16)
36.5
146
(N)
36.5
3,426.0
X
0.0260
X
56.0
=
4,988
R-19 Wall (W. 19.2x6.16)
(N)
621.8
X
0.0740
X
23.0
=
1,058
R-19 Wall (W. 19.2x6.16)
(E)
346.0
X
0.0740
X
33.0
=
845
R-19 Wall (W. 19.2x6.16)
(S)
653.6
X
0.0740
X
26.0
=
1,258
R-19 Wall (W. 19.2x6.16)
(W)
588.5
X
0.0740
X
33.0
=
1,437
X
X
=
X
X
=
X
X
=
X
J
X
=
Page Total
1 9,586
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fanastratinn
Window
Window
Window
Window
Window
Window
Window
Window
Window
Gain
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
Btu/hr
0.0
36.5
36.0
36.5
1,313
0.0
36.5
16.0
36.5
583
0.0
36.5
16.0
36.5
583
0.0
36.5
6.6
36.5
241
0.0
36.5
4.0
36.5
146
0.0
36.5
4.0
36.5
146
0.0
36.5
6.6
36.5
241
0.0
36.5
4.0
36.5
146
0.0
36.5
10.0
36.5
365
Page Total
3, 763
4.0 Occupants X 230 Btuh/occ. = 920
1.0 Dwelling Unit X 1,600 Btu = 1,600
Infiltration: 1.064 X 0.87 X 212.14 X 34 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 59,7]
Latent Gain Btu/hr
Occupants 4.0 Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.87 X 212.14 X 0.00276 = 2,421
Air Sensible CFM ELA AW
R ROOM
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Ezralow Residence-Addition/Alteration 1 8/6/2013
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,426.0 It' Outdoor Wet Bulb Temperature 78 0
Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF
Surfaces Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
I. Coolino Load Temperature Difference (CLTD)
I Fanoctratinn
Window
Window
Window
Window
Window
Window
Window
Window
Window
Ariantatinn
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
Shaded
Area GLF
47.0 X 36.5
126.4 X 36.5
0.0 X 36.5
0.0 X 36.5
0.0 X 36.5
0.0 X 36.5
0.0 X 36.5
0.0 X 36.5
0.0 X 36.5
+
+
+
+
+
+
+
+
+
Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
72.1 =
53.0
33.6
72.1
=
=
60.0
72.1
80.0
72.1
=
10.0
36.6
=
4.0
36.6
=
=
4.0
36.6
4.0
36.6 =
36.6 =
Page Total
8.0
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Btu/hr
Btu/hr
5,534
7,031
4,325
5,767
366
146
146
146
293
Internal Gain
Btu/hr
Occupants
4.0 Occupants X
230 Btuh/occ.
= 920
Equipment
1.0 Dwelling Unit X
1,600 1 Btu
= 1,600
Infiltration:
1.064
X 0.87 X 212.14
X 34 =
6,647
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
59,732
Latent Gain
Btu/hr
Occupants
4.0 Occupants X 200 Btuh/occ.
= 800
Infiltration:
4,771
X 0.87 X 212.14
X 0.00276 =
2,421
Air Sensible
CFM ELA
AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3 221
0
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Ezralow Residence-Addition/Alteration 8/6/2013
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing 1st Floor Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,426.0 ft' I Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF
Surfaces Orientation
Area U -Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
I Panaatrntinn
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
Btu/hr
171
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
Btu/hr
0.0
36.5
16.8
36.6
615
0.0
36.5
20.1
36.6
736
0.0
36.5
4.5
36.6
165
0.0
36.5
10.0
36.6
366
0.0
36.5
10.0
36.6
366
0.0
36.5
6.0
36.6
220
0.0
36.5
30.0
72.1
2,163
0.0
36.5
28.0
72.1
Z018
0.0
36.5
94.5
72.1
6,812
Page Total
13,461
Internal Gain
Btu/hr
Occupants
4.0 Occupants X
230 1Btuh/occ.
= 920
Equipment
1.0 Dwelling Unit X
1,600 Btu
= 1,600
Infiltration:
1.064
X 0.87 X 212.14
X 34 =
6,647
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
59,732
Latent Gain
Btu/hr
Occupants
4.0 Occupants X 200 Btuh/occ.
= 800
Infiltration:
4,771
X 0.87 X 212.14
X 0.00276 =
2.421
Air Sensible
CFM ELA
AW
HEAT GAIN FOR
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Namee
781612013
Ezralow Residence-Addition/Alteration
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 2011 Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area 102.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-30 Roof(R.30.2x 12.16) (N) 102.0 X 0.0320
X 56.0 =
183
R-21 Wall (W.21.2x6.16) (N) 26.0 X 0.0690
X 23.0 =
41
R-21 Wall (W.21.2x6.16) (E) 122.0 X 0.0690
X 33.0 =
278
R-21 Wall (W.21.2x6.16) (S) 26.0 X 0.0690
X 26.0 =
47
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
548
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area GLF
Btu/hr
Window (N) 0.0 X 19.5 +
28.0 X 19.5
= 545
Window (S) 0.0 X 19.5 +
28.0 X 19.6
= 548
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
1,093
Internal Gain
Btu/hr-
Btu/hr
Occupants ants 0.0 Occupants X 230
Btuh/occ. =
0
Equipment 0.0 Dwelling Unit X 1,600
Btu =
0
Infiltration: 1.064 X 0.89 X 6.32 X 37 =
222
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
1,863
Latent Gain
Btu/hr
Occupants 0.0 Occupants X 200
Btuh/occ. =
0
Infiltration: 4,771 X 0.89 X 6.32 X 0.00376 =
101
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
101
EnergyPro 5.1 bv EnerovSoft User Number., 6712 RunCode: 2013-08-06709:58:13 ID:
Pace 21 of 22
•
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ezralow Residence-Addition/Alteration
1 8/6/2013
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Sitting Room Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area 176.0 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-30 Roof(R.30.2x12.16) (N) 176.0 X 0.0320
X
56.0 =
315
R-21 Wall (W.21.2x6.16) (N) 136.0 X 0.0690
X
23.0 =
216
R-21 Wall (W.21.2x6.16) (E) 76.0 X 0.0690
X
33.0 =
173
R-21 Wall (W.21.2x6.16) (W) 132.0 X 0.0690
X
33.0 =
301
X
X
=
X
X
=
X
X
=
X
X
=
X J
X
=
Page Total
1,005
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
Window (N) 0.0 X 19.5 +
20.0
X 19.5
= 389
Window (N) 0.0 X 19.5 +
20.0
X 19.5
= 389
Window (N) 0.0 X 19.5 +
20.0
X 19.5
= 389
Window (N) 0.0 X 19.5 +
20.0
X 19.5
= 389
Window I (E) 80.01 X 41.3 +
0.0
X 84.6
= 3,303
Window (tom 23.7 X 41.3 +
0.3
X 84.6
= 1,004
X +
X
=
X +
X
=
X +
X
=
Page Total
5,865
Internal Gain
Btu/hr-Occupants
0.0 Occupants X 230
Btuh/occ.
=
Equipment 0.0 Dwelling Unit X 1,600
Btu
=
Infiltration: 1.064 X 0.89 X 10.90 X 37 =
383
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,253
Latent Gain
Btu/hr
Occupants77] 0.0 Occupants X 2001
Btuh/occ.
=
o
Infiltration: 4,771 X 0.89 X 10.90 X 0.00376 =
174
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
174
Ene Pro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2013.08-06709:58:13 ID:
Pa a 22 of 22