Loading...
BRES2015-026978-495 CALLE TAMPICO LA Q19INTA, CALIFORNIA 92253 T4bt °('4QuGfw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2015-0269 Property Address: 53600 VIA BELLAGIO APN: 777170021 Application Description: HIDEAWAY / ENGLANDER BLACK / (1) 6,906 SQ FT SINGLE FAMILY Property Zoning: Application Valuation: $428,678.60 Applicant: FEDDERLY & ASSOCIATES 78206 VARNER ROAD STE D #248 PALM DESERT, CA 92211 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: 8 License No.: 5 7 Date: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s)licensed pursuant to the Contractors' State License Law.). (�) I am exempt under Sec. B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: 11111111111111111111 16 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ��n for which t ' permit is issued. ave and will maintain workers' compensation insurance, as required by 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the L bor Code, I shall forthwith comply with those provisions. O Date: Appfant: - WARNING: FAILURE TO SECURE WORKERS' MPENSATIO ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the condition's and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to en er upon the above-mentioned property for inspection purposes. O Date: � � O � Signature (Applicant or ent): Date: 10/8/2015 Owner: H. ENGLANDER AND D. BLACK 1130 TOWER RD BEVERLY HILLS, CA 90210 `z � Contractor: o cD cv ` SUNROSE CORPORATION I I `N S o 72-850 SOMERA ROAD ® PALM DESERT, CA 92260 Q �' U LU _o LU C::, �K (760)773-6633 z Llc. No.: 533670 ��— o WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ��n for which t ' permit is issued. ave and will maintain workers' compensation insurance, as required by 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the L bor Code, I shall forthwith comply with those provisions. O Date: Appfant: - WARNING: FAILURE TO SECURE WORKERS' MPENSATIO ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the condition's and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to en er upon the above-mentioned property for inspection purposes. O Date: � � O � Signature (Applicant or ent): FINANCIAL .1. DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $571.69 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ART IN PUBLIC PLACES - AIPP: $571.69 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $18.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $18.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID'DATE DIF - TRANSPORTATION 250-0000-43200 0 1 $2,842.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE TEMP POWER SERVICE 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE TEMP POWER SERVICE PC 101-0000-42403 0 $16.92 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $41.09 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,OOO5F 101-0000-42403 0 $61.65 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $25.40 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT - QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for 'ELECTRICAL - NEW CONSTRUCTION: $279.94 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF 101-0000-42408 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 $181.29 $0.00 PAID BY' METHOD RECEIPT # CHECK # CLTD BY Total Paid for GRADING: $217.55 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 1 $145.04 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $96.68 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $145.04 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $96.68 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $84.63 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $33.81 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $618.80 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2015 UPDATE 101-0000-20310 0 $1,301.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2015 UPDATE 101-0000-20310 0 $1,301.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MULTI -SPECIES RESIDENTIAL: $2,602.00 $0.00 DESCRIPTION ACCOUNT - QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $709.81 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for NEW CONSTRUCTION PERMIT: $709.81 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,300.00 $1,300.00 7/14/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY FEDDERLY & ASSOCIATES CHECK R7740 99632 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $224.60 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,524.60 $1,300.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $265.98 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $265.98 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ROOF DRAIN 101-0000-42401 0 $60.45 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT, PAID PAID DATE ROOF DRAIN PC 101-0000-42600 0 $60.45 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY 'AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $21.75 $0.00 PAID BY METHOD RECEIPT # CHECK #. CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PLUMBING FEES: $819.67 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $55.73 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for STRONG MOTION INSTRUMENTATION SMI: $55.73 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:•0$1,300.00 Permit Details PERMIT NUMBER City of La Quinta BRES201►Am9 1 !. Description: HIDEAWAY / ENGLANDER BLACK / (1) 6,906 SQ FT SINGLE FAMILY Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED Applied: 7/14/2015 SKH FAMILY DETACHED Approved: 10/2/2015 LUR Parcel No: 777170021 Site Address: 53600 VIA BELLAGIO LA QUINTA,CA 92253 Subdivision: TR 29894-2 Block: Lot: 333 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $428,678.60 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 CHRONOLOGY Details: 6,681SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2013 CALIFORNIA BUILDING CODES. Printed: Thursday, October 08, 2015 2:10:11 PM 1 of 8 �� SYSTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE LUIS URIBE 8/10/2015 8/12/2015 WATTING ON STRUCTURAL NOTE LUIS URIBE 10/1/2015 10/1/2015 WAITING ON STRUCTURAL PLAN CHECK COMMENTS FROM CONSULTANT RECEIVED KAY HENSEL 8/12/2015 8/12/2015 STRUC BACK FROM YOUNG - RFC 8/11/15 PLAN CHECK COMMENTS FROM CONSULTANT RECEIVED KAY HENSEL 10/2/2015 10/2/2015 STRUC APPROVABLE 10-01-15 PLAN CHECK PICKED UP STEPHANIE KHATAMI 8/12/2015 8/12/2015 JOSE CANBS PLAN CHECK SENT TO OUTSIDE PC STEPHANIE KHATAMI 7/14/2015 7/14/2015 PLAN CHECK SUBMITTAL RECEIVED MARY FASANO 9/11/2015 9/11/2015 Printed: Thursday, October 08, 2015 2:10:11 PM 1 of 8 �� SYSTEMS PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 7/14/2015 7/14/2015 RECEIVED SPOKE WITH NICOLE. I LET HER KNOW THAT WE ARE TELEPHONE CALL LUIS URIBE 8/11/2015. 8/11/2015 EXPECTING THE PLANS BACK IN FROM YOUNG ENGINEERING LATER ON THIS AFTERNOON. I SHOULD HAVE THEM READY TO BE PICKED UP IN THE MORNING. DIANA CALLED IN TO CHECK PLAN CHECK STATUS. RETUNED TELEPHONE CALL LUIS URIBE 10/1/2015 10/1/2015 PHONE CALL AND LEFT MESSAGE WITH NICOLE REQUESTING A CALL BACK SO I COULD GIVE STATUS. TELEPHONE CALL LUIS URIBE 10/2/2015 10/2/2015 CALLED HOMEOWNER AND DIANA. PERMIT IS READY TO BE ISSUED CONDITIONS CONDITION DATE DATE DATE CONTACT STATUS REMARKS NOTES TYPE ADDED REQUIRED SATISFIED READY TO ISSUE LUIS URIBE 10/2/2015 10/2/2015 PENDING CHECKLIST CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FEDDERLY & ASSOCIATES 78206 VARNER ROAD PALM DESERT CA 92211 (213)220-5058 STE D #248 CONTRACTOR SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT CA 92260 (213)220-5058 OWNER H. ENGLANDER AND D. BLACK 1130 TOWER RD BEVERLY HILLS CA 90210 (213)220-5058 Printed: Thursday, October 08, 2015 2:10:11 PM 2 of 8 CRWSYSTEMS DESCRIPTION ACCOUNTQTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 1 101-0000-20306 0 $18.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $18.00 $0.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 DIF - COMMUNITY 254-0000-43200 0 $129.00 $0.00 CENTERS DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 DIF - PARK 256-0000-43200 0 $40.00 $0.00 MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 DIF . STREET 255-0000-43200 0 $116.00 $0.00 MAINTENANCE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $0.00 TEMP POWER SERVICE 101-0000-42403 0 $16.92 $0.00 PC Total Paid for ELECTRICAL: $41.09 $0.00 RESIDENTIAL, EA 101-0000-42403 0 $61.65 $0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $25.40 $0.00 ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF Printed: Thursday, October 08, 2015 2:10:11 PM 3 of 8 Cm- SYSTEMS Printed: Thursday, October 08, 2015 2:10:11 PM 4 of 8 (rmV V SYS 7EM5 CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $279.94 $0.00 RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42408 0 $36.26 $0.00 HOME LOT>7KSF RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42600 0 $181.29 $0.00 HOME LOT>7KSF PC Total Paid for GRADING: $217.55 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $145.04 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $96.68 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 FURNACE 101-0000-42402 0 $145.04 $0.00 FURNACE PC 101-0000-42600 0 $96.68 $0.00 VENT FAN 101-0000-42402 0 $84.63 $0.00 VENT FAN PC 101-0000-42600 0 $33.81 $0.00 Total Paid for MECHANICAL: $618.80 $0.00 MULTI -SPECIES RESIDENTIAL 0-8 UNITS 101-0000-20310 0 $1,301.00. $0.00 - 2015 UPDATE MULTI -SPECIES RESIDENTIAL 0-8 UNITS 101-0000-20310 0 $1,301.00 $0.00 - 2015 UPDATE Total Paid for MULTI -SPECIES RESIDENTIAL: $2,602.00 $0.00 Printed: Thursday, October 08, 2015 2:10:11 PM 4 of 8 (rmV V SYS 7EM5 'l PERMIT NUMBER Permit Details City of La Mh. - a BRES2015-0269 Printed: Thursday, October 08, 2015 2:10:11 PM 5 of 8 CO V srs TEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY NEW CONSTRUCTION 101-0000-42400 0 $709.81 $0.00 PERMIT Total Paid for NEW CONSTRUCTION PERMIT: $709.81 $0.00 NEW CONSTRUCTION 101-0000-42600 0 $1,300.00 $1,300.00 7/14/15 R7740 99632 CHECK FEDDERLY & SKH PLAN CHECK ASSOCIATES NEW CONSTRUCTION 101-0000-42600 0 $224.60 $0.00 PLAN CHECK Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,524.60 $1,300.00 BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 FIXTURE/TRAP 101-0000-42401 0 $265.98 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $265.98 $0.00 GAS SYSTEM, 5+ 101-0000-42401 0 $36.26 $0.00 OUTLETS GAS SYSTEM, 5+ 101-0000-42600 0 $24.17 $0.00 OUTLETS PC ROOF DRAIN 101-0000-42401 0 $60.45 $0.00 ROOF DRAIN PC 101-0000-42600 0 $66.45 $0.00 WATER HEATER/VENT 101-0000-42401 0 $36.27 $0.00 WATER HEATER/VENT 101-0000-42600 0 $21.75 $0.00 PC WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $12.09 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $819.67 $0.00 Printed: Thursday, October 08, 2015 2:10:11 PM 5 of 8 CO V srs TEMS .14 'y OF'ft�' - DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY SMI - RESIDENTIAL 101-0000-20308 0 $55.73 $0.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $55.73 $0.00 SINGLE FAMILY 224-0000-203200 $1,837.44 $0.00 DETACHED Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00 Printed: Thursday, October 08, 2015 2:10:11 PM 6 of 8 L L.1 LJ LJ SYS iFMS PARENT PROJECTS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE PLEASE COMPLETE BY JULY 30TH FOR INTERNAL NON-STRUCTURAL - REVIEW BY BH LUIS URIBE 7/14/2015 8/4/2015 8/10/2015 REVISIONS REQUIRED 3 WK FIRST REVIEW COMPLETE. SEE ATTACHED CORRECTIONS LIST. STRUCTURAL - 2 WK YOUNG 7/14/2015 8/4/2015 8/11/2015 REVISIONS REQUIRED ENGINEERING 2ND BLDG NS (2 LUIS URIBE 9/11/2015 9/25/2015 10/1/2015 APPROVED WK) 2ND BLDG STR (2 YOUNG 9/11/2015 9/25/2015 10/1/2015 READY FOR APPROVAL WK) ENGINEERING 1ST PW GREEN AMY YU 9/11/2015 9/25/2015 9/18/2015 APPROVED - NO STRUCTURES WITHIN THE PUE SHEET CONDITIONS Printed: Thursday, October 08, 2015 2:10:11 PM 6 of 8 L L.1 LJ LJ SYS iFMS FIRE LISA NOTTINGHA 9/15/2015 9/29/2015 M 9/16/2015( READY FOR APPROVAL - CONDITION M, 721 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED JSREVIEW - CF'y OF'rtn'� BRE 2015-0269 KS FIRE LISA NOTTINGHA 9/15/2015 9/29/2015 M 9/16/2015( READY FOR APPROVAL - CONDITION Printed: Thursday, October 08, 2015 2:10:11 PM 7of8 CONN SYSTEMS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED JSREVIEW - BRE 2015-0269 KS DOC 8/11/2015 KATHRYN SAMUELS STRUCTURAL (ist).doc 0 COMMENTS 1ST REVIEW - NEW CITY DOC 8/11/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0269 (ist).pdf 1ST REVIEW - STRUCTURAL SOILS Soils_Report_Scope_BR DOC 8/11/2015 KATHRYN SAMUELS REPORT ES 2015-0269.pdf 0 REQUIREMENTS 2ND REVIEW - NEW CITY DOC 10/1/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0269 (2nd).pdf LAQ-IS-RS-133 LAQ-I5-RS-133 ENGLANDER BLACK ENGLANDER BLACK DOC 9/16/2015 LISA NOTTINGHAM 0 RESIDENCE SPRINKLER RESIDENCE SPRINKLER LOT 333.docx LOT 333.docx BRES2015-0269 - 1ST DOC 8/12/2015 LUIS URIBE 1ST REVIEW REVIEW CORRECTIONS 0 CORRECTIONS LIST LIST.docx BRES2015-0269 - 1ST DOC 8/12/2015 LUIS URIBE IST REVIEW REVIEW TRANSMITTAL 0 TRANSMITTAL LETTER LETTER.pdf BRES2015-0269 - DOC 10/2/2015 LUIS URIBE SCHOOL FEE LETTER SCHOOL FEE 0 LETTER.docx DOC 7/14/2015 STEPHANIE KHATAMI GEO TECH 07-14-15.pdf I GEO TECH 07-14-15.pdf 0 Printed: Thursday, October 08, 2015 2:10:11 PM 7of8 CONN SYSTEMS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED, DOC PM10 APPROVAL 09-21- 9/21/2015 STEPHANIE KHATAMI PM10 APPROVAL 09-21- 0 15.pdf 15.pdf ONWER ONWER DOC 10/6/2015 STEPHANIE KHATAMI AUTHORIZATION - AUTHORIZATION - 0 CHANGE CHANGE CONTRACTOR.pdf CONTRACTOR.pdf Printed: Thursday, October 08, 2015 2:10:11 PM 8 of 8 - RV Ld SYS iEMS Building ,660D VIA A Address sJ V Address r -18) �� O Tihf 4 4 Qub4 P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 - 6 Da 2011P./1"IU..1151 "IOM - 226 -5659 Contractor FPAA eA- l4 >t N ss aAr-s. .- n A =0GL gg� & Classif. "1 `l V Lic. # qqql Arch., Engr., Designer dtiiY 1'./I 0 AsC7 o6&s Address Tel. ,Wft As A vve, Lic. # hereb at I lice dun ns of ter 9 (commencingwith Section of Di ' yn 3 of th sin d s s Cod nd my license is in u, e4d BUILDING: TYPE CONST. P. OCC. GR A.P. Number '7771 1,A�-7 177 t//� 6 Y 2! ( Legal Description W i 33 J �7 1_ Qt+29 a pp I4 - q Project Description SF Sq. Ft. Size Newl fI 603 No. No. Dw. T� ,J Stories Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ 'rOWNER-BUILDER DECIAROTION Estimated Valuatic ereby affirm that I exempt from the Contractor' icense Law for the following reason: c. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, PERMIT alter,improve, demolish, or repair any structure, pr fort0i's issuance also requires the applicant for S permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any Plan Chk. Dep. violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty o/ not more than five hundred dollars ($500). Plan Chk, Bal, ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- Const. sions Code: The Contractor's License Law does not apply to an owner o/ property who builds or improves thereon and who does such work himself or through his own employees, provided that Mech. such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden o/ proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the Electrical Plumbing S.M.I. project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with Grading a contractor(s) licensed pursuant to the Contractor's License Law.) 01 am exempt under Sec. B. & P.C. for this reason Driveway Enc. Date Owner Infrastructure WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company )(Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT = TOTAL CONTACT INFORMATION NAME: PHONE: AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line — Rear Setback from Rear Prop. Line _ Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE INSPECTOR Issued by: Date Permit_ Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE R�ichella Valley Unified School District 83-733 Avenue $5, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: she Hideaway Date: October 8, 2015 Owner's Name: Harvey Englander & Donna Black Phone No. 760-773-6633 Project Address: 53-600 Via Bellagio, LaQuinta Project Description: New Single Family Residence APN: 777-170-021 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: October 8, 2015 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code . Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 4803 Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile Amount per Sq.Ft. $3.36 homes being relocated within the same school district's Amount Collected $16138.08 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: r 4 4 A 0z aZ'UJWJs- NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c/mydocs/devfees/certificate of compliance form updated 3-2007 11/2010 RECORDING REQUESTED BY Lawyers Title - IE WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: The Harvey Englander Living Trust 1130 Tower goad Beverly Hills, CA 90210 APN: 772-510-021 Escrow No: PDL13174-L:139, CM Title No: 615691406 DOC # 2015-0078479 02/27/2015 11:10 AM Fees: $21.00 Page 11of 3 Doc T Tax Paid Recorded in Official Records County of Riverside Peter Aldana Assessor, County Clerk & Recorder "This document was electronically submitted to the County of Riverside for recording" Receipted by: CTOLOSSA —100.\ 0 —160 Space above th d •0)L-0 GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(St DOCUMENTARY TRANSFER TAX IS $355.30, X computed on full value of property conveyed , AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Thomas J. Nokes, an unmarried man Recorder's use hereby GRANT(S) to Harvey A. Englander, Trustee of the Harvey A. Englander Living Trust dated August 21, 2008 the following described real property in the City of La Qulnta, County of Riverside, State of CALIFORNIA: For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: 53600 Via Bellaglo, La Quinta, CA 92253 Dated: bru 01 s J. Nokes 1,A notary public o other officer completing this certificate verifies only the identity of the individual who signed the ocument to t0ch this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STAT IFORNIA ) ) SS. COUNTY OF (-'0A7/LA dc3 fA ) :» O ��/i►�.2o/S before me, r��[ 4. •.Srn,rv-.S�gA4iv�' Nota Public, ' On rypersonally appeared Thomas J. Nokes who proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/ara subscribed to the within instrument and acknowledged to me that he/sheA y executed the same in his/herA4wir authorized capacity(ies), and that by his/her kh r signature(s) on the Instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the Instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. lowL1111104 LEA...e..3W ,4TAL WITNESS my hand and official seal. COMM. 02082700 Notary Public - Contra ty Cosh County Comm. Ex9iros Oct 19,2010 t cf&-4.4..4. Signature MAIL TAX STATE AS DIRECTED ABOVE RECORDING REQUESTED BY Lawyers Title - IE WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: The Harvey Englander Living Trust 1130 Tower Road Beverly Hills, CA 90210 APN 772-510-021 Escrow No: PDL13174-LT139-CM Space above this line for Recorder's use GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(Si DOCUMENTARY TRANSFER TAX IS .$355.30, X computed on full value of property conveyed , AND FOR A VALUABLE CONSIDERATION, receipt of which'is hereby acknowledged; Thomas J. Nokes, an unmarried man hereby GRANT(S) to Harvey A. Englander, Trustee of the Harvey. A. Englander Living Trust dated August 21, 2008 the following described real property in the City of La Quinta, County of Riverside, State of CALIFORNIA: For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: 53600 Via.Bellagio, La Quinta, CA 92253 Dated: Februarv_18.2015 J. Nokes. A notary publico,p,other officer completing this certificate verifies only the Identity of the individual who signed the ocument to V.Kich this certificate is attached, and not the truthfulness, accueacy, or validity of that document. STA IFORNIA ) ) SS. COUNTY OF_:C0)tiIr R NOJ,m ) On /�2ai,T before me,,Notary Public, personally appeared Thomas J. Nokes who proved to me on the basis of satisfactory evidence) to be the person(s) whose names) is/ate subscribed to the within instrument and acknowledged to me that he/si ag4ey executed the same in his/ -,lieir authorized capacity(ies), and that by his/he4t#4etr signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct.,.,�,,,,,,, CAROLE A. 8RlITH-STALLINI WITNESS my hand and official seal. COMM. 02082700 m Notary Public - California Contra Coats County = My Comm. Expires Oat, 19,.2018 MAIL TAX STA AS DIRECTED ABOVE PENALTY OF PERJURY FOR NOTARY SEAL (GOVERNMENT CODE 27361.7) I certify under penalty of perjury that the Notary Seal on the document to which this statement is attached'reads as follows: NAME OF NOTARY: CAROLE A. SMITH-STALLINGS DATE COMMISSION EXPIRES: October 19, 2018 COUNTY WHERE BOND IS FILED (if applicable): CONTRA COSTA STATE WHERE BOND IS FILED: CA COMMISSION NUMBER (if applicable): 2082700 PLACE OF EXECUTION: RIVERSIDE, CA DATE: February 27; 2015 SIGNATURE. PRINT NAME: MIKE AMR EIN EXHIBIT 'W' THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: PARCEL 1: LOT 333 OF AMENDED TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPTING THEREFROM TO GRANTOR; AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN.ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER -SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. 1_l361:104 NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION RECORDED ON DECEMBER 13, 2002, AS INSTRUMENT NO. 2002-745938, OF OFFICIAL RECORDS. ASSESSOR'S PARCEL NUMBER; 777-170-021-2 BOE -502-A (PI) REV. 12 (05-13) PRELIMINARY CHANCE OF OWNERSHIP REPORT To be completed by transferee (buyer) prior to a transfer of subject property. in accordance with Section 480.3 of the Revenue and Taxation Code. A Preliminary Change of Ownership Report must be filed with each conveyance in the County Recorders office for the county where the property is located. NAME AND MAILING ADDRESS OF BUYER/ TI ANSFEREE !Make necessary corrections to the printed name and mailing address) the Harvey A. Englander Living Trust dated Augus, 21; 2008 1130 Tower Road Beverly Hills, CA 90210 Escrow No.: POL13174-139-CM Title No.: 615691406 f ASSESSOR'S PARCELNUM13ER 777-170-021 SELLERfMANSFEROR Thoma J. Noka BUYER'S DAYTIME TELEPHONE NUMBER BUYER'S EMAIL ADDRESS STREET ADDRESS OR PHYSICAL LOCATION OF REAL PROPERTY 53600 Via BdIagio, La Quina, CA 92253 MAIL PROPERTY TAX INFORMATION TO (NAME) the Harvey A. Englander Living Trust dated August 21, 2008 ADDRESS 1130 Tower Road, Beverly Hills, CA 90210 YES -o NO This property is intended as my pnnciptil residence. If YES, please indicate the date ofoccupancy MO DAY : YEAR or intended occupanry: it PART I: TRANSFER INFORMATION Please complete all statements. This section contains possible exclusions from reassessment for certain types ortransfers. YES NO o "ft, li. The recorded document creates, terminates, or reconveys a lenders interest in the property. o `rem A. This transfer is solely between spouses (addition or removal of er spouse, death ofa spouse, divorce settlement. etc.). o b. B. This transfer is solely between domestic partners currently registered with the California Secretary of State (addition,or removal of a partner, o 116, 1. toffrom a revocable trust that may be revoked by the transferor and is for the benefit of death ofa partner, termination settlement, 'etc.). o *'h. • C. This is a transfer. o between parent(s) and child(ren) o from gmndparcni(s) to grandchild(ren). o • D. This transfer is the result ofa cotenant's death. Date ofdeath o '1-%. • E. This transaction is to replace a principal residence by a person 55 years of age or older. remain exactly the same after the transfer. a Within the same county? o YES ANO o O. This transfer is to the first purchaser of o new building containing an active solar energy system. F. This transaction is to replace a principal residence by a person who is severely disabled as defined by Revenue and Taxation Code section 69.5. Please provide any other Information that will help the Assessor understand the nature or the transfer. Within the same county? o YES o NO o %'N, G. This transaction is only a correction of the name(s) of die person(s) holding title to the property, (e.g., u name change upon marriage): THIS DOCUMENT IS NOT SUBJECT TO PUBLIC INSPECTION If YES, please explain: o "ft, li. The recorded document creates, terminates, or reconveys a lenders interest in the property. o ',is, I. This transaction is recorded only as a requirement for financing purposes or to creme, terminate, or reconvey a security interest (e.g.. cosigner). If YES, please explain: o 'b, J. The recorded document substitutes a trustee ofa trust, mortgage, or other similar document. K This is a transfer of property: o 116, 1. toffrom a revocable trust that may be revoked by the transferor and is for the benefit of o the transferor, and/or o the transferor's spouse o registered domestic partner. o "1., 2, tofftom a trust that may be revoked by the creattrdgrantor/tnutor who is also a joint tenant, and which names the other joint tenants) as beneficiaries when the creator/grantor/trustor dies. o 3. loffrom an irrevocable trust for the benefit of the o creator/grantor/trustor and/or o grantor'stirustors spouse o grantoesitrustoes registered domestic partner. o L. This property is subject to a lease with a remaining lease term of 35 years or more including written options. o M. This is a transfer between parties in which proportional interests of the transferor(s) and transferee(s) in each and every parcel being transferred remain exactly the same after the transfer. a N This is a transfer subject to subsidized low-income housing requirements with govemmentally imposed restrictions. o • O. This transfer is to the first purchaser of o new building containing an active solar energy system. • Please refer to the instructions for Pan 1. Please provide any other Information that will help the Assessor understand the nature or the transfer. THIS DOCUMENT IS NOT SUBJECT TO PUBLIC INSPECTION B0E-502-A (P2) REV, 12 (05-13) PART Z. OTHER TRANSFER INFORMATION Check and complete as applicable, A. Date of transfer, if other than recording dale:, B: Typeoftransfir. Purchase 6; Foreclosure '9 Gift :4' Trade or exchange ;G, Merger, stock, or partnership acquisition (,Form BOE -100=B) `o Contract of sale. Date of contract: o Inheritance. Date of death: 'p: Sale/leaseback o'. Creation of a lease o Assignment ofa leasee Termination of a lease, Date lease began: Original term in years (including written options): Remaining term in years (including written options): o Other. Pleaseexplain:• C. Only a partial interest in the property was transferred;, .o YES ANO If YES; indicola the percentage transferred: PART 3. PURCHASE PRICE AND TERMS OF SALE Check and complete as applicable;. A. Total purchase price. $ r B. Cash down payment or value of trade or exchange excluding closing costs Amount ;5. V`e1..; C. First deed of trust U 'o interest for years. Monthly payment $ Amount :S :o FHA (_Discount Paints) o Cal -Vet ;o" VA`(____ _Discount Points) o Fixed rate o Variable rate ;,p Bank/Savings & Loan/Credit Union o Loan carried by seller Belloon'payment S Due date: D. Second deed of trust (a] % interest for years. Monthly payment $ Amount 3 o Fixed rate o Variable rate o Bank/Savings & LomVCrcdit Union o Loan carried by seller o Balloon payment $ Due date: E. Was an Improvement Bond or other public financing assumed by the buyer? o YES o NO Outstanding Balance $ F. Amount, ifany, of real estate commission fees paid by the buyer which are included in the purchase price. $ ``not G. The property was purchased:. Through real estate broker. Broker name: C[iAV1' 1T�1�i Phone number._i'lleA:50-5.3 13 d Direct from seller :o :From a family member -Relationship o Other. Please explain: - H. Please explain any special terms, seller concessions, broker/agent foes waived, financing, and any other information (e.g., buyer assumed the existing loan balance) that would assist the Assessor in the valuation of your property. PART 4. PROPERTY INFORMATION Check and complete as applicable. A. Type of property transferred q Single-family residence ;6 Co-opfown-your-own ;o Manufactured home o Multiple -family residence. Number of units:.... :o Condominium \Unimproved lot a Other. Description:-(i.e., timber, mineral, water rights, etc,) .ti Timeshare .6. ComrnerciaVlndustrial B. o YES X NO Personal/business property, or incentives, provided by seller to buyer are included in the purchase price. Examples of personal property are furniture, farm equipment, machinery, etc, Examples of incentives are club memberships, etc. Attach list ifavailable, If YES, enter the value If the personal/business property. $ C. 0 YES N NO A manufactured home' isincluded in the purchase price. If YES, enter the value attributed to the manufactured home: $ q. YES \ NO The manufactured home is subject to local property tax. IFNO, enter decal number. D. cj. YES y NO The property produces rental or other Income. If YES, the income is from: o; Lease/rent Contract . o Mineral rights a Other. E., The condition of the property at the time of sale war.\Good o Average o Fair u Poor CERTIFICATION I certifv (or declare) that the foregoing and all information hereon, including any accompanying statements or documents, is true and correct to the best of my knowledy'e ortiAellef' 10 . } The Assessors office may contact you for additional information regarding this transaction., ......?' % Recorder LARRY W. WARD P.O. Box 751 COUNTY OF RIVERSIDE Riverside, CA 92502-0751 n _ ASSESSOR -COUNTY CLERK -RECORDER (951) 486-7000 Website: www.riversideacr.com DOCUMENTENTARY TRANSFER TAX AFFIDAVIT WARNING ANY PERSON WHO MAKES ANY MATERIAL MISREPRESENTATION OF FACT FOR THE PURPOSE OF AVOIDING ALL OR ANY PART OF THE DOCUMENTARY TRANSFER TAX IS GUILTY OF A MISDEMEANOR UNDER SECTION 5 OF ORDINANCE 516 OF TH E COUNTY OF RIVERSIDE AND IS SUBJECT TO PROSECUTION FOR SUCH OFFENSE. ASSESSOR'S PARCEL NO. 777-170-021-2 1 declare that the documentary transfer tax for this Property Address: 53600 Via Bellagio - Vacant Land, Lot 333 . La transaction is: $355.30. Quinta. CA 92253 If this transaction is exempt from Documentary Transfer Tax, the reason must be identified below. I CLAIM THAT THIS TRANSACTION IS EXEMPT FROM DOCUMENTARY TRANSFER TAX BECAUSE: (The Sections listed below are taken from the Revenue and Taxation Code with the exception of items 9 and 10 which aretaken from Riverside County Ordinance 516). Please check one or explain in "Other".) 1. _ Section 11911. The consideration or value of the property, exclusive of any liens and encumbrances is $100.00 or less and there is no additional consideration received by the grantor. 2. _.Section 11911. The conveyance transfers to a revocable living trust by the grantor or from a revocable living trust to a beneficiary 3. _ Section 11921. The instrument was given to secure a debt. 4. _ Section 11922. The conveyance is to a governmental entity or political subdivision. 5. _ Section 11925. The transfer is between individuals and a legal entity or partnership, or between legal entities; and does not change the proportional interests held. 6. _ Section 11926. The conveyance is to a grantee who is the foreclosing beneficiary and the consideration paid by the foreclosing beneficiary does not exceed the unpaid debt 7. .Section 11927. The conveyance relates to a dissolution of marriage or legal separation. 8. _ Section 11930. The conveyance is an inter vivos gift` or a transfer by death. *Please be aware that information stated on this document may be given to and used by governmental agencies, including the Internal Revenue Service. Also, certain gifts in excess of the annual Federal gift tax exemption may trigger a Federal Gift Tax. In such cases; the Transferor (donor/grantor) may be required to file Form 709 (Federal Gift Tax Return) with the Internal Revenue Service. 9. Section 8., This easement is not perpetual, permanent, or for life 10. — Section 9. This document is a cease for a term of less than (35) years (including written options). 11. , Other (Include explanation and authority) I DECLARE UNDER PENALTY OF PERJURY THAT THE FOREGOING IS TRUE AND CORRECT. Executed this j �f -day of -G 20At5 at ut as r'1 City State L.:�.rr 'Sign ature o Affiant Printed Name of Affiant 'Name of Firm (if applicable) Address of Affiant � 2�3 Telephone Number of Affiant (including area code) This form is subject to the California Public Records Act (Government Code 6250 et. Seq.) For Recorder's Use: Affix PCOR Label Here w YOUNG . e ENGINEE.. I -NG t Letter of Transmittal.` To: City of La Quinta Today's Date: 10-1-15" 78-495 Calle Tampico City Due Date: 9-25-15 ' La Quinta,'CA 92253 Project Address:' 53600 Via Bellagio Attn: Kay ••Plan Check.#: - '' BRES2015-0269 ' Submittal:.❑ 1st ❑' 4th ® 2nd ❑ 5th ❑ 3d ❑ Other: We are forwarding: ® By Messenger, •❑' By;Mail (Fed Ex or UPS), ❑ ` ' Your Pickup Includes: # Of' Descriptions:' ,Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ® '1 Revised Structural Plans ❑ `Structural Calculations ® 1 -Revised Struct. Calcs Truss Calculations, Floor, ❑� Revised Truss - and Roof ' ® 2 Soils Report ,� Revised Soils Report ` Structural Comment List/ ® 1 ❑ 1, Approved Structural',Plans Responses ® 1 Redlined Structural Plans ❑, ` Approved Structural Calcs ElRedlined Structural Calcs `, ❑ Approved Truss Calcs: ❑Redlined Truss Calcs ❑ ..7 Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. -If you have any questions, please call. - Time = 2 HR This Material Sent for: ❑ Your Files ® Per Your Request ❑ Your Review ❑ . Approval ❑ Checking ❑ At the request of: r Other: ❑. BY: Kathryn Samuels- amuelsPalm PalmDesert Office : ®' (760) 772-5107 - Other. ❑ 4 T ©1 2015 CITY OF LA QUINTA ?COMMUNITY DEVELOPMENT September 2, 2015 Mr. Harvey Englander and Ms. Donna Black 1130 Tower Road Beverly Hills, CA 90210 Re: Lot 333 at 53600 Via Bellagio Final Design Review #1 Dear Mr. Englander and Ms. Black: This correspondence shall serve as notification that the Hideaway' Design Review Committee (DRC) reviewed your. final construction documents as part of the September 1, 2015 meeting. The project was approved and construction may commence after a Pre -Construction Meeting is held at the lot. In addition, the following three items must be submitted prior to installation for review and approval: 1. The landscape pot design and specifications must be submitted. 2. The exterior sconce design must be submitted as it was not detailed on the working drawings. 3. The entry step light is detailed as dark bronze and the proposed location for the lights is within the light colored stone. The committee suggests modifying the color of the light and/or relocating the lights to the plinth, or another location that will be less visible. Please contact Brook Marshall at 760-219=8057. or by email at*DRCFacilitator@gmail.com with any questions or to schedule your Pre -Construction Meeting once a Building Permit has been obtained. No temporary facilities or work can start at the lot prior to the Pre -Construction Meeting being held. Thank you for your understanding. Sincerely, THE HIDER WAY DESIGN REVIEW COMMITTEE Title: ` Date: cc: Harvey@ekapr.com Fedderly Assoc. GM Future Designs DRC File Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. If you wish to pursue an appeal, please contact the Association's DroDerty manager directly. Plan Submittal Job Site Building Permit Number. Project Description: SFR Exempt: O (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E -Mail Address 9/10/2015 53-600 Via Bellagio (parcel #777-170.021) Harvey Englander 1130 Tower Rd Beverly Hills, Ca. 90210 213-741-1500 x 518 HarvevAlekaor.com Project Manager's Namel Fedderly & Assoc Project Manager's Phone Number 70D-773-5205 x107 PmjectMansgeesE-maQAddress1 NlcoleCOhadderlv.com Builder/ Contractor Fedderly & Assoc Number, Street or PO Box 78206 Varner Rd suite D City, state, Postal Code Palm Desert, CA. 92211 Project Square Footage approx. 6681 sq ft City Approval By Date of City Approval Materials To Be Discarded: Product Tons Trash 26.50 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 7.00 Recyclable Cardboard 0.00 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 0.50 Recyclable Concrete 29.00 Recyclable Tile (roof) 0.75 Recyclable Drywall 3.00 Recyclable Wood I 8.00 Recyclable Donated /Reuse' 0.00 Recyclable Landscape Debris 0.00 Recyclable 'Describe Items ls: Recycle Trash Projected Diversion: 48.3 r 26.5 164.56% I understand It Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP Is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued In the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bf-monthly reports. If se fRauling, fu ma I from this project site must be taken to an approved recycler or transfer 9ro- ner / Day p / Proje Manager / Superintends Date 7 Sladden July 15, 2015 Engineering 45090 Golf Center Parkway, Suite F, Indio, CA. 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951).845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 Fedderly & Associates 38747 Nopales Road Palm Desert, California 92211 Project: Proposed Englander Residence 53-600 Via Bellagio The Hideaway La Quinta, California Subject: Soluble Sulfate Content Project No. 544-14141 15-07-28 CITY OF LA QUINTA BUILDIING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE MOZ /,�lf BY Ref: Geotechnical Update prepared by Sladden Engineering dated June 18, 2015; Project No. 544-15141, Report No. 15-06-252 As requested, we have sampled the surface soil on the subject lot to determine the soluble sulfate content as it relates to selecting appropriate concrete mix designs. Laboratory testing indicated a soluble sulfate content of 5600 ppm (0.560 percent) that corresponds with the "severe" exposure category in accordance with Table 3 of ACI 318-08 Chapter 9.. In accordance with ACI 318-08, special sulfate resistant concrete mix designs will be required for structural concrete. Structural concrete in contact with the soil should have a minimum compressive strength of 4500 psi and a maximum water/cement ratio of 0.45. If you have questions regarding this letter or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderson Principal Engineer Letter/gvm BRETT L. ' OS ANDERSON No. C45389rr EXP, 9/30/16 rr CIVIL ENGINEERING Copies: 4 / Addressee C OE Slad�'en Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 Date: July 21, 2015 Account No.: 544-15141 Customer: Fedderly & Associates Location: The Hideaway, 53-600 Via Bellagio, Lot 333, La Quinta Analytical Report Sulfate Series Soluble Sulfates per CA 417 PPM. 5600 Soluble Chloride per CA 422 PPM 1150 Sulfate 544-15141 072115 -TABLE 19=A-2—REQUIREMENTS FOR SPECIAL EXPOSURE t^aNmm�►�s • - MAXIMUM. • IAINIMUMI�, NOR AL'-WEIGWAND . WATER:tEMENtMOUS UGHYWEIGHT. MATERIALS` RAT10; BY. ; AGGREGATECONCRETE, EXPOSURE CONDITION •WEIGHTTNORMAL'.WEIGHT• AGGAEGATE CONCRETE • CONCRETE - = x 0.00689•1or MPs Concrete intended to have low permeability when WATER- SOLUBLE exposed to water 0.50 4,000 Conerele exposed to'freezing and thawing in a moist condition or to deicing chemicals 0.45 4,500 For corrosion protection for reinforced concrete exposed to chlorides from deicing chemicals, salts or -A9or�ate, . Conereie,;pstt EXPOSURE " brackish:watcr, orsprayfiom tRese'sources 0.40 5,000 TABLE 19-A-3—REQUIREMENTS.FOR CONCRETE EXPOSED TO SULFATE -CONTAINING -SOLUTIONS a�ancnnttous matcnals ratio or higher stTcngth may bescquired for Cow perincability•or forpr don 2 against corrosion *of embedded items or freezing and thawing (Table 19-A-2). Seawater- ?Pozzola n that has been determined by test or service record to improve sulfate resistance when used in concrete con - 2 -264 NORMAL -WEIGHT LIGHTWEIGHT :AGGREGATE AGGREGATE CONCRETE - MMdMum`Water- Cementlttous I^,-NorTn0- V1�eloht snd WATER- SOLUBLE SULFATE Materista�Retlo;by:. Whtweloht' SULFATE SO IN SOIL, PI�RC NTAGEBY Wei' h4 NoA sl WelgR. -A9or�ate, . Conereie,;pstt EXPOSURE " WEIGHT . SULFATE(SO�)IN WATER, m PP CEMENT TYPE oncretal Concrete ' x Q.l>0684'lor MPa_ Negligible 0.00-0.10 0-150 — Moderate2. 0.10-0.20 150-1;500 II. IP(MS), is '030- 4,000 (MS) Severe 0.20-2.00 1500-[0,000 V 0.45r 4,500 Ycry severe Over 2.00 Ovcr 16,000 V plus 0.45 ¢,500 • pozzolan3 • to lower war a�ancnnttous matcnals ratio or higher stTcngth may bescquired for Cow perincability•or forpr don 2 against corrosion *of embedded items or freezing and thawing (Table 19-A-2). Seawater- ?Pozzola n that has been determined by test or service record to improve sulfate resistance when used in concrete con - 2 -264 i; BUILDING ENERGY ANALYSIS REPORT R PROJECT: Englander Residence 53-600 Via Bellagio La Quinta, CA 92253 Project Designer: Fedderly and.Associates 38-747 Nopales Road Palm Desert, CA 92211[DATE28��Z// ITY OF UINTA (760) 773-5205 UILDING & SAFLA LA ETY DEPT APR®VED PT. FOR CONSTRUCTION Report Prepared by: BY 2_ Jon Scott r Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 RECEIVED Job Number: SEP 1 12015 CIrr OF Date: COMMUNI7-y Y D�V�Dp A 1 MENT 8/20/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is • authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPro 6.7 by EnergySoft User Number: 6712 ID: 7 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IPOD Project Name: Englander Calculation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF11t-01-E Page 1 of 13 - GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Englander 04 05 02 Calculation Description Tide 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 53-600 Via Bellagio Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4803 15 Number of Zones 5 16 Slab Area (ft2) 3617 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ft?) I N/A 21 Glazing Percentage (%) 30.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance j{ :M�\ 1 d3`a�1 iti t{, -I. f it It'"*W- p"''C 40 `�1' 44, ld 02 This building incorporates featureNhat require field'testing and/orlverification,by a�certified; HERS rater; under the supervision of a CEC-approved HERS provider. Y � '�.�,. 03 This building incorporates one ormore Special Featuresa; �how�n below REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.31 5.51 1.80 24.6% Space Cooling 138.45 135.92 2.53 1.8% IAQ Ventilation 0.87 0.87 0.00 0.0% Water Heating 5.34 7.13 -1.79 -33.5% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 151.97 149.43 2.54 1.7% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE qPOD Project ame: Englander Ca culation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1I*-01-E Page 2of13' HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: j —None— ENERGY None— ENERGY DESIGN RATING This is the sum of the annual TDV energy. consumptioh'for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated byJitle 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. ;'E „ ' �� �. ,per, ' p ` ,' ., margin YVse -EnergY Design Rating Percent Improvement Total Energy (kTDV/f2-yr)* 189.1:9w x..: 186 65 y:, }ry ; F� �• 2.54 1.3% `A I! i6— is i _;� 3... 9A i..r V t a..OF a_ s a * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Englander 4803 1 5 5 4 1 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-2010:24:11 CERTIE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project ame: Englander Calculation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 *-01-E Page 3 of 13 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 owner Conditioned HVAC 1 ownerl 1212 9 DHW Sys 1 living Conditioned HVAC 2 great2 1480 9 DHW Sys 1 2nd floor Conditioned HVAC 3 2ND3 1186 9 DHW Sys 1 office Conditioned HVAC 3 2ND3 420 9 DHW Sys 1 casita Conditioned HVAC 4 casita4 505 9 DHW Sys 1 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 HERS Provider: . CaICERTS inc. Report Generated at: 2015-08-2010:24:11 CERTI0E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Englander Ca culation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1-01-E Page 4 of 13' OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) N Wall owner R-21 Wall (W.21.2x6.16) 0 Left 1180 108 90 E Wall owner R-21 Wall (W.21.2x6.16) 90 Back 500 100 90 S Wall owner R-21 Wall (W.21.2x6.16) 180 Right 620 60 90 W Wall owner R-21 Wall (W.21.2x6:16) 270 Front 400 12 90 Roof owner R-38 Roof Attic 1212 N Wall 2 living R-21 Wall (W.21.2x6.16) 0 Left 450 48 90 NE Wall living R-21 Wall (W.21 2x6.16) 45 - specify - 200 32 90 E Wall 2 living R-21 Wall (W.21.2x6.16) 90 Back 950 320 90 SE Wall living R-21 Wall (W.21.2x6.16) 135 - specify - 200 32 90 S Wall 2 living R-21 Wall (W.21.2x6.16) 180 Right 1375 158 90 W Wall 2 living R-21 Wall (W.21.2x6.16) 270 Front 375 20.1 90 Roof 2 living R-38 Roof Attic 1480 N Wall 3 2nd floor f2b21 Wall -(W.21- 2xfi?16)� " 0f Left «...•,-� .s 900 39 90 E Wall 3 2nd floor 12121 Wall (W:2fx6P16)` yp '9Q Backs 630 70 90 S Wall 3 2nt1'floor R21'Wall (VVF212x6 16) X180 tF2iglit' '` 900 62 90 W Wall 3 2nd floor " qdJ W,�II.(W.21 2z6.16)t (J 2•,7,0 1 0 F o_nt 630 59.6 90 NW Wall 2nd floor R-21 Wall (W.21.2x6.16) 315 - specify - 300 15 90 Roof 3 2nd floor R-38 Roof Attic 1186 N Wall 4 office R-21 Wall (W.21.2x6.16) 0 Left 375 98 90 E Wall 4 office R-21 Wall (W.21.2x6.16) 90 Back 250 25 90 W Wall 4 office R-21 Wall (W.21.2x6.16) 270 Front 600 83.6 90 Roof 4 office R-38 Roof Attic 420 N Wall 5 casita R-21 Wall (W.21.2x6.16) 0 Left 600 27.6 90 E Wall 5 casita R-21 Wall (W.21.2x6.16) 90 Back 400 90 90 S Wall 4 casita R-21 Wall (W.21.2x6.16) 180 Right 600 13.8 90 W Wall 5 casita R-21 Wall (W.21.2x6.16) 270 Front 400 22.6 90 Roof 5 casita R-38 Roof Attic 505 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTI0 E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD Project Name: Englander Cation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 & -01-E Eage5of13 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic owner Attic Roofowner Ventilated 3 0.1 0.85 No. No Attic living Attic Roofliving Ventilated 3 0.1 0.85 No No Attic 2nd floor Attic Roof2nd floor Ventilated 3 0.1 0.85 No No Attic office Attic Roofoffice Ventilated 3 0.1 0.85 No No Attic casita Attic Roofcasita Ventilated 3 0.1 0.85 • No No ,+� r ER �- H ERS PROVIDER Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08062015-744 Report Generated at: 2015-08-2010:24:11 CERTI0 E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ROD Project Name: Englander Ca culation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 F* -01-E Page 6 of 13 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Multipli Width (ft) Height (ft) er Area (ft2) U -factor SHGC Exterior Shading N Window N Wall (Left -0) - - 1 8.0 0.32 0.24 Insect Screen (default) N1 Window N Wall (Left -0) - - 1 14.0 0.32 0.24 Insect Screen (default) N 2 Window N Wall (Left -0) - - 1 8.0 0.32 0.24 Insect Screen (default) M Window N Wall (Left -0) - - 1 8.0 0.32 0.24 Insect Screen (default) L Window N Wall (Left -0) -- - 1 35.0 0.32 0.24 Insect Screen (default) L 2 Window N Wall (Left -0) - - 1 35.0 0.32 0.24 Insect Screen (default) K Window E Wall (Back -90) - - 1 100.0 0.35 0.33 Insect Screen (default) 8 Window S Wall (Right -180) - - 1 60.0 0.32 0.24 Insect Screen (default) P Window W Wall (Front -270) - - 1 4.0 0.32 0.24 Insect Screen (default) P 2 Window W Wall (Front -270) - - 1 4.0 0.32 0.24 Insect Screen (default) P 3 Window W Wall (Front -270) - - 1 4.0 0.32 0.24 Insect Screen (default) 6 Window N Wall,? (Left -0)r, �.-� rp tl�, - f 1 48.0 1 0.35 0.33 Insect Screen (default) H Window NE Wall (- specify5) �i - 1 s "32.0 0.32 0.24 Insect Screen (default) 7 Window XA E Wall-2(Ba�-90)i -" y 1 � 200 0 0.35 0.33 Insect Screen (default) J WindowE Wall_2P(Ba&-90):� �_. 1 - 40.0 0.35 0.33 Insect Screen (default) G Window E Wall 2 (Back -90) - - 1 80.0 0.48 0.32 Insect Screen (default) H 2 Window SE Wall (- specify -135) - - 1 32.0 0.32 0.24 Insect Screen (default) 62 Window S Wall 2 (Right -180) - - 1 48.0 0.32 0.24 Insect Screen (default) G 2 Window S Wall 2 (Right -180) - - 1 80.0 0.48 0.32 Insect Screen (default) F Window S Wall 2 (Right -180) - - 1 10.0 0.32 0.24 Insect Screen (default) F 2 Window S Wall 2 (Right -180) -- - 1 10.0 0.32 0.24 Insect Screen (default) F 3 Window S Wall 2 (Right -180) - - 1 10.0 0.32 0.24 Insect Screen (default) Q Window N Wall 3 (Left -0) - - 1 15.0 0.32 0.24 Insect Screen (default) Q 2 Window N Wall 3 (Left -0) - - 1 15.0 0.32 0.24 Insect Screen (default) U Window N Wall 3 (Left -0) - - 1 3.0 0.32 0.24 Insect Screen (default) U 2 Window N Wall 3 (Left -0) - - 1 3.0 0.32 0.24 Insect Screen (default) U 3 Window N Wall 3 (Left -0) - - 1 3.0 0.32 0.24 Insect Screen (default) S1 Window E Wall 3 (Back -90) - - 1 14.0 0.32 0.24 Insect Screen (default) 18 Window E Wall 3 (Back -90) - - 1 42.0 0.35 1 0.33 Insect Screen (default) Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Englander Ca culation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CFI F* -01-E Page 7 of 13 S12 Window E Wall 3 (Back -90) - - 1 14.0 0.32 0.24 Insect Screen (default) S Window S Wall 3 (Right -180) - - 1 12.5 0.32 0.24 Insect Screen (default) S2 Window S Wall 3 (Right -180) - - 1 12.5 0.32 0.24 Insect Screen (default) T Window S Wall 3 (Right -180) - - 1 6.0 0.32 0.24 Insect Screen (default) T 2 Window S Wall 3 (Right -180) - - 1 6.0 0.32 0.24 Insect Screen (default) S3 Window S Wall 3 (Right -180) - - 1 12.5 0.32 0.24 Insect Screen (default) S4 Window S Wall 3 (Right -180) - - 1 12.5 0.32 0.24 Insect Screen (default) 17 Window W Wall 3 (Front -270) - - 1 42.0 0.32 0.24 Insect Screen (default) R Window W Wall 3 (Front -270) - - 1 8.8 0.32 0.24 Insect Screen (default) R 2 Window W Wall 3 (Front -270) - - 1 8.8 1 0.32 0.24 Insect Screen (default) Q 3 Window NW Wall (- specify -315) - - 1 15.0 0.32 0.24 Insect Screen (default) Al Window N Wall 4 (Left -0) - - 1 18.0 0.32 0.24 Insect Screen (default) 131 Window N Wall 4 (Left -0) - - 1 80.0 0.35 0.33 Insect Screen (default) C Window E Wall 4 (Back -90) - - 1 25.0 0.32 0.24 Insect Screen (default) B Window W Wall 4 (Front -270) - - 1 18.0 0.32 0.24 Insect Screen (default) 1 Window W Wall 4;(Front-270)3 � rr �*Kv=o z* - V 1 50.0 0.35 0.33 Insect Screen (default) A Window '"�" 4 W Wall 4 (Front -27Q) ' - 1 ! ( 15.6 0.32 0.24 (default) Insect Screen default CB Window ' MWal1-5'(Left�'0)9 lkh:o b*=* 9 A sx 1 '13'8 0.32 0.24 Insect Screen (default) CB 2 Window A N Wka11;5 (Left -0) +! t # I 13.8 0.32 0.24 Insect Screen (default) CC Window E Wall 5 (Back -90) - - 1 18.0 0.32 0.24 Insect Screen (default) 21 Window E Wall 5 (Back -90) - - 1 54.0 0.35 0.33 Insect Screen (default) CC 2 Window E Wall 5 (Back -90) - - 1 18.0 0.32 0.24 Insect Screen (default) CB 3 Window S Wall 4 (Right -180) - - 1 13.8 0.32 0.24 Insect Screen (default) CA Window W Wall 5 (Front -270) - - 1 11.3 0.32 0.24 Insect Screen (default) CA 2 Window W Wall 5 (Front -270) -- - 1 11.3 0.32 0.24 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft2) U -factor Door W Wall 2 20.1 0.50 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: C810ERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-2010:24:11 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Englander Ca culation DatefTime: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xmi CF1*-01-E Page 8 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers owner 1212 130 None 0.8 No • Cavity/ Frame: no insul. / 2x4 Top Chrd living 1480 130 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofowner Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) casita 505 100 None 0.8 No • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 - Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofliving Attic Roofs, Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) w • Cavity/ Frame: no insul. /2x4 Top Chrd - 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd floor Attic Roofs Wood Framed,Ceiling din rO.0 . A' 1� none 0.644 Roofing: Light Roof (Asphalt Shingle) 2x4 Top Chord of Roof Truss @ 24 Cavity/ Frame: no insul. / 2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Attic Roofoffice Attic RoofsW,00d Fram!ed-d1ili6g >d X- m. O.C. none EE�� 0:644 Roofing: Light Roof (Asphalt Shingle) ` fr Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofcasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab owner 1212 130 None 0.8 No Covered Slab 2 living 1480 130 None 0.8 No Covered Slab 3 office 420 60 None 0.8 No Covered Slab 4 casita 505 100 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD Project ame: Englander Calculation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 *-01-E Page 9 of 13 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/3 DHW Pipe Insulation, All Lines DHW Heater 1 3 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation`}Parallel>Pip�ng� pp" � ; Compact;DistributioMn, Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/3;- Distribution Name � — � — — . --aws Ta 1W—_— RL M R IS— W-- fes. WR %F 1. ." As M 34 Al �._....ac SPACE CONDITIONING SYSTEMS ., 01 ."q 02 e . — 03 * ' ,,.., +. ' IW '6— .. y 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC 1 ownerl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC 2 great2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC 3 2ND3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC 4 casita4 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTI'fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Sculation OD Project ame: Englander Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 -01-E Page 10 of 13 HVAC - HEATING UNIT TYPES 01 02 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13.1 16.5 Not Zonal Single Speed Cooling Component 1 -hers -cool Required 350 Required Required Required Cooling Component 4 -hers -cool Required Cooling Component 2 ' SplitAirCond_r 13.1 16.5 Not Zonal Single Speed% Cooling Component 1 -hers -cool .._ Cooling Component 3 f SplitAirCond' i 1 C : 0 71'6.500" Zonall Controlled y Single Speed g p Cooling Component I 1 -hers -cool Cooling Component 4 Splii4tond 13A ? ?16.5 / NotZonal* i Single Speed Cooling Component 1 -hers -cool T -I F_:. . �> Sim *-% %—.# eP I L.Or L. VA HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required Cooling Component 2 -hers -cool Required 350 Required Required Required Cooling Component 3 -hers -cool Required 350 Required Required Required Cooling Component 4 -hers -cool Required 350 Required Required Required Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD Project ame: Englander Ca culation DatefTime: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 10-01-E Page 11 of 13 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3 -hers -dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 102 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required _ s 6.0 Not Required Not Required Not Required Not Required — Air Distribution System 2 -hers -dist Required " X6.0 �a , Not R quuii`red �.� Not Required Not -,Required Not Required — Air Distribution System 3 -hers -dist RequirAdk% 6.0 Not Requi+ed N161IRequired Not Required Not Required — Air Distribution System 4 -hers -dist RequirediA6.0� Not�Requi�r`ed NotRequir NotRRegwred Not Required — HVAC -FAN SYSTEMS 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 3 -hers -fan Required 0.58 Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD Project ame: Englander Calculation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xmi HVAC Fan'4-hers-fan Required 0.58 CF1 FO -01-E Page 12 of 13 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 93.03 0.25 Default 0 Required COOLING VENTILATION 01 02 03 04 05 Name Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans WH Fan 1 61 0.52459 32 1 WH Fan 2 61 0.52459 32 1 WH Fan 3 f ; 61 0.52459 32 1 WH Fan 4 i ` 61 0.52459 32 1 .� Zm,: r La ^' Sk H E RS PROVIDE A -iL Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-20 10:24:11 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project ame: Englander Calculation Date/Time: 10:22, Thu, Aug 20, 2015 Calculation Description: Title 24 Analysis Input File Name: Englander-Fedderly-15.xml CF1 W011 -E Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2015-08-20 10:28:32 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted two the enforcementagencyfo{r appr�ovawith thin,building permit application. Responsible Designer Name: :: •"`L L(Responsible Designer Signature: %c�Xi.�cd7 1C Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2I15-k828:32D Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0185293C-000000000-0000 Registration Date/Time: 2015-08-20 10:28:32 HERS Provider: CaicERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08062015-744 Report Generated at: 2015-08-2010:24:11 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Englander Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/20/2015 Project Address 53-600 Via Bellagio La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,803 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R38 4,803 New Wall Wood Framed R 21 11,339 New Slab Unheated Slab -on -Grade - no insulation 3,617 Perim = 420' New Demising Wood Framed R 13 2,810 New Door Opaque Door - no insulation 20 New FENESTRATION Orientation Area(ft) I Total Area: 1,476 Glazing Percentage: 30.7 U -Fac SHGC OverhangSidefins New/Altered Avera a U -Factor: Exterior Shades 0.35 Status Left (N) 108.0 0.320 0.24 none none Bug Screen New Rear (E) 436.0 0.350 0.33 none none Bug Screen New Right (S) 60.0 0.320 0.24 none none Bug Screen New Front (tM 12.0 0.320 0.24 none none Bug Screen New Left (N) 128.0 0.350 0.33 none none Bug Screen New Left (NE) 32.0 0.320 0.24 none none Bug Screen New Rear (E) 80.0 0.480 0.32 none none Bug Screen New Rear (SE) 32.0 0.320 0.24 none none Bug Screen New Right (S) 153.8 0.320 0.24 none none Bug Screen New Right (S) 80.0 0.480 0.32 none none Bug Screen New Left (N) 84.6 0.320 0.24 none none Bug Screen New Rear (E) 89.0 0.320 0.24 none none Bug Screen New Front (W) 115.8 0.320 0.24 none none Bug Screen New Front (NW) 15.0 0.320 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 owner Ducted Ducted Attic 8.0 New HVAC 2 great Ducted Ducted Attic 8.0 New HVAC 3 2ND Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 3 Small Storage Gas 50 0.66 All Pipes Ins New Ene Pro 6.7 by EnerqySoft User Number: 6712 RunCode: 2015-08-20710:25:07 /D: Pae 16 of 42 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Englander Residence Building Type m Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 8/20/2015 Project Address 53-600 Via Bellagio La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,803 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) . Special Features Status FENESTRATION Total Area: 1,476 Glazing Percentage: 30.7 % I New/Altered Average U -Factor: 0.35 Orientation Area ft2 U -Fac SHGC Overhang Sidefins Exterior Shades Status Front (tM 50.0 0.350 0.33 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 4 casita Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status I EnemvPro 6.7 by EnemySoft User Number., 6712 RunCode: 2015-08-20710:25:07 ID: Pa a 17 of 42 4 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the corn liance approach used. Exceptions may apply. Review the respective code section or more information. Building Envelope Measures: §110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of § 10-111 (a). §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R=19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(6): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). ' § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor.permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §I50.0(e)1B:: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. §150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pip2 and insulation. 4 2013 Low -Rise Residential Mandatory Measures Summary § I50.00)2C: Pipe for cooling system lines shall be insulated as specified in § I50.0Q)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.06)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18113 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. is 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)] C: § ] 30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § I50.0(k) ] D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). §150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. §150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5• and all other requirements in § 150.0(k)2. § I50.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in ' 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 r 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in 110.9, §130.0, §130.2, 130.4, 140.7 and 141.0. § I50.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in $110.9, § 130.0, §130.2, § 130.4, § 140.7 and § 141.0. §I50.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 § 130.0 § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I50.0(k)] 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a)]: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through $110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10 6 through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § ] 10.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § ] 10.10(e)1: The main electrical service panel shall have a minimum bulbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0 SYSTEM HEATING AND COOLING LOADS SUMMARY 4HHVAC Project Name -nglander Residence Date 8/20/2015 System Name VAC 1 owner Floor Area 1,212 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,081 Return Vented Lighting Return Air Ducts Return Fan Ventilation 182 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 18,865 2,143 419 20,971 Total Output Btuh 89,000 0 889 0 Output Btuhls ft 73.4 801 Cooling System 0 Output per System 49,000 8,025 4,046 182 8,809 Total Output Btuh 49,000 1,489 1 8891 30,156 6,189 -1,489 Total Output Tons 4.1 801 Total Output Btuhls ft 40.4 Total Output s ft/Ton 296.8 29,892 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24APA748/58PH"110 39,209 2,368 89,000 Airflow cfm/s ft 1.32 Airflow cfm/Ton 391.8 Total Adjusted System Output 39,209 2,368 89,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air % 11.4 % Outside Air cfm/s ft 0.15 Note: values above Ivan at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 182 cfm 72 OF 67 OF 119 OF 119 OF Heating Coil Supply Fan ° 1,600 cfm 119 F ROOM 92 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F 76/62°F 53/52°F Outside Air 182 cfm Supply Fan Cooling Coil 54 152 OF 1,600 cfm 52.7% ROOM 71 / 59 °F 70159 OF A�� _ I Ene►gyPro 6.7 by EnergySoR User Number: 6712 RunCode: 2015-08-20T10:25:07 /D: Page 22 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name . nglander Residence Date 8/20/2015 System Name HVAC 2 great Floor Area 1,480 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,084 Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 222 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 33,121 2,617 778 30,116 Total Output Btuh 89,000 0 Output Btuh/s ft 60.1 1,561 1,150 Cooling System 0 0 Output per System 58,000 9,750 4,501 222 10,740 Total Output Btuh 58,000 1,489 1 1,561 1 47,480 7,118 -1,489 Total Output Tons 4.8 1,150 Total Output Btuh/s ft 39.2 Total Output s ft/Ton 306.2 41,666 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Ad Airflow cfm 2,000 Carrier 24APA760/58PH"110 46,146 3,467 89,000 89,000 F Jan 1 AM Airflow cfm/s ft 1.35 Airflow cfm/Ton 413.8 Outside Air % 11.1 % Total Adjusted System Output 46,146 3,467 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 MI Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 109 OF 109 OF Outside Air I 222 cfm Heating Coil Supply Fan o 108 F 2,000 cfm ROOM 71 OF 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F 76/63°F 54/53°F Outside Air Ar 222 cfm Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm 55.3% ROOM 71 / 60 OF 70 / 60 OF EnergyPro 6.7 by EnergySoff User Number: 6712 Run Code: 2015-08-20710:25:07 ID: Page 23 of 42 F- L i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name nglander Residence Date 812012015 System Name HVAC 3 2ND Floor Area 1,606 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 1,918 29,776 Return Vented Lighting 0 Return Air Ducts 1,403 Return Fan 0 Ventilation 241 10,599 Supply Fan 1,489 Supply Air Ducts 1,403 TOTAL SYSTEM LOAD 1 44,670 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 89,000 2,840 736 28,208 Total Output Btuh 89,000 Output Btuh/s ft 55.4 1,077 Cooling System 0 Output per System 58,000 4,695 241 11,663 Total Output Btuh 58,000 7,536 -1,489 Total Output Tons 4.8 1,077 Total Output Btuh/s ft 36.1 Total Output s ft/Ton 332.3 40,536 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24APA760/58PH"110 45,947 Total Adjusted System Output 45,947 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,973 89,000 3,973 89,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.25 Airflow cfm/Ton 413.8 Outside Air % 12.0% Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar 241 cfm 71 OF 67 OF 109 OF 109 OF Heating Coil Supply Fan 2,000 cfm o 108 F ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/63°F 76/63°F 55/54°F Outside Air Ar 241 cfm Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm 56.3% ROOM 71 /60°F 70/60°F EnergyPro 6.7 by EnergySolf User Number: 6712 RunCode: 2015-08-20710:25:07 ID: Page 24 of 42 4 i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name nglander Residence Date 812012015 System Name HVAC 4 casita Floor Area 505 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 510 11,135 893 244 Return Vented Lighting 0 Return Air Ducts 525 Return Fan 0 Ventilation 1 76 3,353 2,157 76 Supply Fan 0 Supply Air Ducts 525 TOTAL SYSTEM LOAD 1 15,537 3,050 PEAK Heating System Sensible Output perSystem 71,000 13,502 Total Output Btuh 71,000 Output Btuh/s ft 140.6 515 Cooling System 0 Output perSystem 38,000 3,676 Total Output Btuh 38,000 0 Total Output Tons 3.2 515 Total Output Btuh/s ft 75.2 Total Output s ft/Ton 159.51 1 18,209 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA736/58MVB90 30,588 0 71,000 Airflow cfm/s ft 2.38 Airflow cfm/Ton 378.9 Outside Air % 6.3% Total Adjusted System Output 30,588 0 71,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.15 values above given at ARI conditions TING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of HeatingPeak r26 Outside Air 76 cfm 72 OF 69 OF 124 OF 124 OF H Heating Coil Supply Fan 1,200 cfm 124 ° F ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 73/59°F 73/59°F 49/48°F Outside Air 76 cfm Supply Fan Cooling Coil 49 / 48 OF 1,200 cfm 44.6% ROOM 70/57°F 70/57°F EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-20710:25:07 ID: Page 25 of 42 ROOM HEATING PEAK LOADS Project Name Englander Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Time of Peak Floor Area 1,212.0 ft2 Outdoor Dry Bulb Temperature Indoor Dr Bulb Tem erature 72 OF Conduction Area R-38 Roof Attic R-21 Wall (W.21.2x6.16) Dual Tinted Non metal .32.24 fx opp Dual Tinted Non metal .35.33 Slab -On -Grade "R-13 Wall 1,212.0 2,420.0 180.0 100.0 perim = 130.0 661.0 U -Value X 0.0260 x 0.0690 X X X X 0.3200 0.3500 0.7300 0.1020 X X X X X X X 46 X 46 X X X X X X 0 X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X 1.064 X 1,212 X 9.00 X 0.361 Schedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM Page Tc ,60] XC Al Date 8/20/2015 Jan 1 AM 26 OF 1,450 7,681 c 2,650 c 1,610 4,365 0 tal 17,756 46 971 AT *F X X 46 46 X 46 X X 46 46 X X X X X X X X X X X X X 0 X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X 1.064 X 1,212 X 9.00 X 0.361 Schedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM Page Tc ,60] XC Al Date 8/20/2015 Jan 1 AM 26 OF 1,450 7,681 c 2,650 c 1,610 4,365 0 tal 17,756 46 971 C ROOM HEATING PEAK LOADS Project Name Englander Residence Date 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great, Dining & Nook Floor Area 1,480.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,480.0 X 2,939.9 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 46 c 1,770 46 = 9,331 46 = 4,637 46 = 2,090 46 0 3,533 46 = 462 46 c 4,365 0 = 0 = = = = = = = = = = = = = = = Page Total 26,189 /60] X 46 = 3,927 AT R-38 Roof Attic 0.0260 R-21 Wall (W.21.2x6.16) 0.0690 opp Dual Tinted Non metal .35.33 288.0 X X 0.3500 Dual Tinted Non metal. 32.24 142.0 0.3200 Tinted metal.48.32 160.0 X 0.4800 Wood Door 20.1 X 0.5000 Slab -On -Grade perim = 130.0 X X X X X 0.7300 "R-13 Wall 712.0 0.1020 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 1,480 X Area Ceiling another room 9.00 X 0.361 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 30,116 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-20710:25:07 ID: Page 31 of 42 • ROOM HEATING PEAK LOADS Project Name Englander Residence Date 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2ND Floor Room Floor Area 1,186.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,186.0 X 3,114.4 X 203.6 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F 46 = Btu/hr R-38 Roof Attic 0.0260 1,418 R-21 Wall (W..21.2x6.16) 0.0690 46 = 9,885 Dual Tinted Non metal.32.24 0.3200 46 = = 2,997 opp Dual Tinted Non metal .35.33 42.0 X X 0.3500 46 676 'R-13 Wall 512.0 0.1020 0 = = 0 X X X X = = = X X X = = X X X X = X X X X = = = X X X X X = = = = X X = = Page Total /60] X 46 AT X X X X through an interior surface to X 1,186 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 9.00 X 0.361 Height ACH 14,977 = 3,147 TOTAL HOURLY HEAT LOSS FOR ROOM 18,123 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-20710:25:07 ID: Page 32 of 42 ROOM HEATING PEAK LOADS Project Name Date Englander Residence 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Entry Time of Peak Jan 1 AM Floor Area 420.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 °F Conduction Area U -Value AT °F Btu/hr R-38 Roof Attic 420.0 X 0.0260 X 46 = 502 R-21 Wall (W.21.2x6.16) 1,018.4 X 0.0690 X 46 = 3,232 Dual Tinted Non metal .32.24 76.6 X 0.3200 X 46 = 1,128 opp Dual Tinted Non metal. 35.33 130.0 X 0.3500 X 46 = 2,093 Slab -On -Grade perim = 60.0 X 0.7300 X 46 = 2,015 'R-13 Wall 420.0 X 0.1020 X 0 = 0 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 8,970 Infiltration:[ 1.00 X 1.064 X 420 X 9.00 X 0.361 /60] X 46 = 1,114 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,084 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-08-20T10:25:07 ID: Page 33 of 42 • ROOM HEATING PEAK LOADS Project Name 7 Englander Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Guest Floor Area 505.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.3200 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F 46 = 46 = 46 c Btu/hr R-38 Roof Attic 505.0 604 R-21 Wall (W.21.2x6.16) 1,846.0 5,859 Dual Tinted Non metal. 32.24 100.0 1,472 opp Dual Tinted Non metal.35.33 54.0 X 0.3500 46 = c = 869 Slab -On -Grade perim = 100.0 X X X X 0.7300 46 3,358 'R-13 Wall 505.0 0.1020 0 0 = = = X X X X X X X X = = = = = = = = X X X X X X X X X X X = = = + X X X Page Total /60] X 46 AT X to another room 9.00 X 0.361 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 505 .X Area 12,163 = 1,340 TOTAL HOURLY HEAT LOSS FOR ROOM 13,502 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-08-20710:25:07 /D: Page 34 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,212.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ODaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation (►M (N) Area X X X X X X X X X U -Factor X X X X X X X X I X CLTD' = = = = = = = = 1,212.0 0.0260 56.0 1,072.0 0.0690 23.0 400.0 0.0690 33.0 560.0 0.0690 26.0 388.0 0.0690 33.0 661.0 0.1020 0.0 0.0 15.3 35.0 15.3 0.0 15.3 35.0 15.3 I= 19.2 100.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration N N1 N M L L K 8 P Orientation (N) (N) (N) (N) (N) (N) (E) (S) (W) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 15.3 8.0 15.3 0.0 15.3 14.0 15.3 0.0 15.3 8.0 15.3 0.0 15.3 8.0 15.3 0.0 15.3 35.0 15.3 0.0 15.3 35.0 15.3 0.0 19.2 100.0 38.8 0.0 15.3 60.0 15.4 0.0 15.3 4.0 29.6 Page Total Btu/hr 1,765 1,701 911 1,005 6, tstu►n r 122 214 122 122 536 536 3,884 922 118 6, 57 Internal Gain Btu/hr Occupants 3 6 Occupants X 245 Btuh/occ. = 891 Equipment 1,212 Floor Area X 0.50 w/sgft 2,068 Infiltration: 1.064 X 1.27 X 49.99 X 42 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,8651 Latent Gain Btu/hr Occupants 3 6 Occupants X 155 Btuh/occ. = 564 Infiltration: 4,771 X 1.27 X 49.99 X 0.00523 = 1,580 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5641 I EnerovPro6.7 by EnerovSoR User Number., 6712 Run Code: 2015-08-20710:25:07 ID: Paae 35 of 42 1 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 1 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,212.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X L X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr P (M 0.0 X 15.3 + 4.0 X 29.6 = 118 P (tM 0.0 X 15.3 + 4.0 X 29.6 = 118 X + X = X + X = X + X = X + X = X + X = X + X = X + I X = Page Total 236 Internal Gain Btu/hr Occupants 3 6 Occupants X 245 Btuh/occ. = 891 Equipment 1,212 Floor Area X 0.50 w/sgft = 2,068 Infiltration: 1.064 X 1.27 X 49.99 X 42 = 2,828 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,865 Latent Gain Btu/hr Occupants 3 6 Occupants X 155 Btuh/occ. = 564 Infiltration: 4,771 X 1.27 X 49.99 X 0.00523 = 1,580 Air Sensible CFM ELA Aw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 564 EnemyPro 6.7 by Ene Soft User Number: 6712 RunCode: 2015-08-20T10:25:07 ID: Page 36 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 1 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great, Dining & Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 1,480.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Onaaue Surfaces R-38 Roof Attic R-21 Wall (W..21.2x6.16) R-21 Wall (W.21.24.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.24.16) R-21 Wall (W.21.2x6.16) Wood Door 'R-13 Wall Orientation (►M (N) (NE) (E) (SE) (S) (►M W Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,480.0 0.0260 56.0 402.0 0.0690 23.0 168.0 0.0690 29.0 630.0 0.0690 33.0 168.0 0.0690 31.0 1,217.0 0.0690 26.0 354.9 0.0690 33.0 20.1 0.5000 33.0 712.0 0.10201 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FP_nP_Atratinn 6 H 7 I J G H 6 G F Oripntatinn (N) (NE) (E) (E) (E) (SE) (S) (S) (S) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 19.2 48.0 19.2 0.0 15.3 32.0 23.0 0.0 19.2 200.0 38.8 0.0 19.2 40.0 38.8 0.0 21.5 80.0 40.5 0.0 15.3 32.0 20.8 0.0 15.3 48.0 15.4 0.0 21.5 80.0 21.5 0.0 15.3 10.0 15.4 Page Total Btu/hr 2,155 638 336 1,435 359 2,183 8, Btu/hr 924 7,768 1,554 3,238 667 737 1,724 154 17,501 Internal Gain Btu/hr Occupants 4.4 Occupants X 245 Btuh/occ. 1,( Equipment 11480 Floor Area X 0.50 w/sgft = 2,; Infiltration: 1.064 X 1.27 X 61.04 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,121 Latent Gain Btu/hr Occupants 44 Occupants X 155 Btuh/occ. = 688 Infiltration: 4,771 X 1.27 X 61.04 X 0.00523 = 1,929 Air Sensible CFM ELA OW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6881 EnemvPro 6.7 by EnerovSoft User Number: 6712 RunCode: 2015-08-20710:25:07 ID: Paae 37 of 42 1 • FJ r . RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great; Dining & Nook Outdoor Dry Bulb Temperature 112 OF Floor Area 1,480.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total • 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr F (S) 0.0 X 15.3 + 10.0 X 15.4 = 154 F (S) 0.0 X 15.3 + 10.0 X 15.4 = 154 X + X = X + X = X + X - X + X = X + X = X + X = X + X = Page Total 30 Internal Gain Btu/hr Occupants 4 4 Occupants X 245 Btuh/occ. = E1,088 Equipment 1,480 Floor Area X 0.50 W/Sgft = 2,526 Infiltration: 1.064 X 1.27 X 61.04 X 42 = 3,453 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,121 Latent Gain Btulhr Occupants 4 4 Occupants X 155 Btuh/occ. = 688 Infiltration: 4,771 X 1.27 X 61.04 X 0.00523 = 1,929 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 688 EnergyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-08-20T10:25:07 /D: Page 38 of 42 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 1 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2ND Floor Room Outdoor Dry Bulb Temperature 112 OF Floor Area 1,186.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 1,186.0 0.0260 56.0 861.0 0.0690 23.0 560.0 0.0690 33.0 838.0 0.0690 26.0 570.4 0.0690 33.0 285.0 0.0690 30.2 512.0 0.1020 0.0 15.3 0.0 15.3 14.0 I I= 19.2 42.0 Page Total Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Q Q U U U S1 18 S1 S OriPntatinn Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 15.3 15.0 15.3 0.0 15.3 15.0 15.3 0.0 15.3 3.0 15.3 0.0 15.3 3.0 15.3 0.0 15.3 3.0 15.3 0.0 15.3 14.0 29.6 0.0 19.2 42.0 38.8 0.0 15.3 14.0 29.6 0.0 15.3 12.5 15.4 Page Total Btu/hr 1,727 1,366 1,275 1,503 1,2991 7, Btu/hr 230 230 46 46 46 414 1,631 414 192 Internal Gain Btu/hr Occupants 3.6 Occupants X 245 Btuh/occ. Equipment 1,186 Floor Area X 0.50 w/sgft 2,1 Infiltration: 1.064 X 1.27 X 48.92 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,543 Latent Gain Btu/hr Occupants 3 6 Occupants X 1551 Btuh/occ. = 551 Infiltration: 4,771 X 1.27 X 48.92 X 0.00523 = 1,546 Air Sensible CFM EIA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 551 EnercvPrn 6.7 by EnernvSoR User Number: 6712 Run Code: 2015-08-20710:25:07 /D: Paae 39 of 42 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 1 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2ND Floor Room Outdoor Dry Bulb Temperature 112 OF Floor Area 1,186.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 70 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF S T T S S 17 R R Q Internal Gain (S) (S) (S) (S) (S) (►M (1M (►M (NVt9 0.0 0.0 X X X X X X X X X 15.3 + + + + + + + + + 12.5 X X X X X X X X X 15.4 = = = = = = = = = 15.3 6.0 15.4 0.0 0.0 15.3 6.0 15.4 15.3 12.5 15.4 0.0 0.0 0.0 0.0 0.0 15.3 12.5 15.4 15.3 42.0 29.6 15.3 8.8 29.6 15.3 8.8 29.6 15.3 1 15.0 23.0 Page Total 3.6 Occupants X 245 Btuh/occ. 1,186 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.27 X 48.92 X 42 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 3 6 Occupants X 155 Btuh/occ. Infiltration: 4,771 x 1.27 x 48.92 x 0.00523 = Air Sensible CFM ELA AW &I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Run Co de: 2015-08-20710:25:07 Btu/hr Btu/hr 192 92 92 192 192 1,241 260 260 Z867 Btu/hr 872 2,024 Z767 19,543 Btu/hr 551 1,546 551 C i a RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name78/20/2015 ate Englander Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Office Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 420.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (1M 420.0 X 0.0260 X 56.0 = 612 R-21 Wall (W.21.2x6.16) (N) 277.0 X 0.0690 X 23.0 = 440 R-21 Wall (W.21.2x6.16) (E) 225.0 X 0.0690 X 33.0 = 512 R-21 Wall (W.21.2x6.16) (W) 516.4 X 0.0690 X 33.0 = 1,176 'R-13 Wall 420.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 2,739 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Al (N) 0.0 X 15.3 + 18.0 X 15.3 = 276 B1 (N) 0.0 X 19.2 + 80.0 X 19.2 = 1,540 C (E) 0.0 X 15.3 + 25.0 X 29.6 = 739 B (IM 0.0 X 15.3 + 18.0 X 29.6 = 532 1 (1M 0.0 X 19.2 + 50.0 X 38.8 = 1,942 A (W) 0.0 X 15.3 + 15.6 X 29.6 = 461 X + X = X + X = X + Ix = Page Total 5,489 Internal Gain Btu/hr Occupants 1.3 Occupants X 245 Btuh/occ. = 309 Equipment 420 Floor Area X 0.50 w/sgft = 717 Infiltration: 1.064 X 1.27 X 17.32 X 42 = 980 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,234 Latent Gain Btu/hr Occupants 13 Occupants X 155 Btuh/occ. = 195 Infiltration: 4,771 X 1.27 X 17.32 X 0.00523 = 547 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 195 EnemyPro 6.7 by EneMVSoft User Number. 6712 Run Code: 2015-08-20T10:25:07 /D: Page 41 of 42 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Englander Residence 1 8/20/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Temoerature Oaaaue Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) "R-13 Wall Orientation Casita Guest Outdoor Dry Bulb Temperature 505.0 ft2 Outdoor Wet Bulb Temperature 70 OF 1 Outdoor Daily Ranae: Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 505.01 0.0260 56.0 572.4 0.0690 23.0 310.0 0.0690 33.0 586.2 0.0690 26.0 377.4 0.0690 33.0 505.0 0.1020 0.0 0.0 15.3 18.0 29.6 0.0 15.3 13.8 15.4 0.0 15.3 11.3 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestratinn CB CB CC 21 CC CB CA CA Orientation .112 OF 78 OF 34 OF Btu/hr 735 908 706 1,052 859 1 4,2611 Area X X X X X X X X15.3 X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 15.3 13.8 15.3 0.0 15.3 13.8 15.3 0.0 15.3 18.0 29.6 0.0 19.2 54.0 38.8 0.0 15.3 18.0 29.6 0.0 15.3 13.8 15.4 0.0 15.3 11.3 29.6 0.0 11.3 29.6 Page Total Btu/hr 211 211 532 2,097 532 212 334 334 Internal Gain Btulhr Occupants 15 Occupants X 245 Btuh/occ. = 371 Equipment 505 Floor Area X 0.50 w/sgft 862 Infiltration: 1.064 X 1.27 X 20.83 X Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11.1351 Latent Gain Btu/hr Occupants 15 Occupants X 155 Btuh/occ. = 235 Infiltration: 4,771 X 1.27 X 20.83 X 0.00523 = 658 Air Sensible CFM ELA AW • 1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Run Code: 2015-08-20T10:25: 07