Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-569 MUPs
O P.O. Box 1304 L.A QUINTA, CALIFORNIA 92247-1504 78-495 CALLS TA�IPICO (760) 777-7000 LA QUI\TA, CALIFORNIA 92253 FAX (760) 777-7101 December 20, 2004 Christopher McFadden 72925 Fred Waring Dr. Palm Desert, CA 92260 SUBJECT: Approval of Minor Use Permit 2004-569 Dear Mr. McFadden: Your request for Minor Use Permit 2004-569 to allow an attached, guesthouse for a new residence at 53-709 Via Bellagio for Mr. and Mrs. John. Botle is hereby approved. Enclosed is the approved original Deed Restriction for this Minor Use Permit. It must be signed by Mr. and Mrs. John Botle in front of a Notary Public. The original approved documents are then to be recorded with the County Recorder with a recorded copy given to us for our files. Until the recorded copy is received, our Minor Use Permit file is not complete. After we receive our copy we will provide our clearance to the Building Department to issue the building permit. Should you have any questions, please call me at (760) 777-7070. Very truly yours, 1 � ttAll-r * Tim Nguyen Assistant Planner Attachment C: Building and Safety Department PP :\stan\mu Itr app 2004-569.doc RECORDING REQUESTED BY: City of La Quinta — City Clerk's Offic e P0. Box 1504 La Quinta, CA 92247-1504 WHEN RECORDED PLEASE MAIL TO: Christopher McFadden 72925 Fred Waring Dr. Palm Desert, CA 92260 ;lop.ris1, COVENANT AND AGREEMENT RESTRICTING THE USE OF THE RESIDENCE AT 53-709 VIA BELLAGIO, LA QUINTA, CALIFORNIA This covenant and agreement are made and executed this 17`h day of December, 2004_by Mr. and Mrs. John Botle, as the record owner(s) of the property described herein. The City of La Quinta, a Municipal Corporation, is hereby made a party to this agreement for the purposes set forth below. The undersigned hereby certifies that he/she is the. property owner of the following described real property in the City of La Quinta, County of Riverside, State of California: Lot 322 of. Tract 29894-2, as per record map on file with the Recorder of Riverside County In consideration of the City of La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and agree to and with said City to restrict the use of said property as follows: 1. The guest house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2004-569); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zone District) and 9.60.1 10 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (i.e., a maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zon�r'g aid' o -her ' des as set forth in the La Quinta Municipal Code, as may be amended from time to time. This covenant and agreement shall run with the land and shall be binding upon future owners, their successors, heirs, or assigns, and ourselves, and shall continue in effect while said accessory building remains on the real property or unless otherwise released by the authority of the City of La Quinta. All leases of said dwelling and/or property shall be subject to this restriction. This agreement shall be entitled to the remedy of injunctive relief in addition of any remedy in law or equity. This covenant and agreement and the provisions hereof are irrevocable, except by the written consent of all parties to the agreement, including the City of La Quinta, a municipal corporation. The City shall have the right to enforce each and every provision hereof and the parties agree that the agreement shall not be rescinded, revoked, modified, or otherwise amended or changed, without the expressed written consent of the City first being obtained. In the event that the owners, their heirs, assigns or successors in interest, shall fail to perform any obligation hereunder, they hereby agree to pay all costs and expenses incurred by the City of La Quinta in securing performance of such obligation, including attorney's fe es. By: Thomas P. Genovese Date City .Manager/Interim Community Development Director City of La Quinta X X X Signature(s) Dated: Printed Name of all owners(s) STATE OF CALIFORNIA ) COUNTY OF RIVERSIDE I CITY OF LA QUINTA ) On December 20, 2004 , before me, Regenia Hensley, Notary Public, personally appeared THOMAS P. GENOVESE personally known to me to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. R tA HENSLEY Notary Public Commission # 1521423 Expiration: October 23, 2008 (Seal) REGENIA iEPISLEY CotmNufon � 1621423 Notary PubIC • CaAtornia RivvefWO County tvty Comm. E= Oct 23.:?�--tj8 Sladden- Engineering • 6782 Stanton Ave., Suite A, Buena Park; CA.90621 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax (760) 772-3895 May 12, 2004 Project No. 544-4244 04-05-327 Mc Fadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, California 92260 -� .7.01 Project:. 5341PPVia Bellagio Hideaway —Lot 322 La Quinta, California Subject: Geotechnical Update Ref: Geotechnical Engineering Report prepared by Earth Systems Consultants dated • September 22, 2000, File No. 07117-10, Report No..00-09-772. Report of Testing and Observation During Rough Grading prepared by Earth Systems Southwest dated August 28, 2002, File No. 07117-11, Report No. 01-07-718. Geotechnical Update prepared by Sladden Engineering dated February 25,, 2003, Project No. 544-2199, Report No. 03-02=106. Report of Observations and Testing During Fine Grading prepared by Sladden Engineering dated August 13, 2003, Project No. 544-2199, Report No. 03-04-225. As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed single family residences. The project site is located at 53-709 Via Bellagio withi n the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight. wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The lot was previously graded during the rough grading of the Hideaway project site and was recently regraded. The rough grading included overexcavation of the native surface soils along with the placement of engineered fill material to construct the building pads. The recent regarding included processing the surface soils along with minor cuts and fills to construct the individual building pads. Some additional overexcavation was performed in areas where the building envelopes were reconfigured. The site grading is summarized in the referenced Report of Observations and Testing During Rough Grading along with the compaction test results. 0 • • In • 0 • • 0 ° TITLE 24 REPORT Title 24 Report for: B O Y L E Main House 53 --Via Bellagio La Quinta, CA 92253 ?09 Project Designer: McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Report Prepared By: Micah Combs C.M. Energy Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 C 017 LA 0)1!, 11�11 T A Job Number: 0316.00 Date: 7/22/04 0 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. 0316.00 User Number. 1086 .n • 0 0 0 • r 0 0 9. N N • Mandatory Measures Checklist: Residential (Page 1 of 2). MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an l asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into `l the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures - - whether they are shown elsewhere in the documents or on this checklist only. • • • • ,O F • • 0 is DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ® '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value. ®"§ 150(c): Minimum R-13 waif insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no E] than 2.0 greater pemfinch. ® §118: Insulation specified or installed meets insulation quality standards. Indicate type and forth. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. © Installation §150(e): of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® §150(): Setback thermostat on all applicable heating and/or cooling systems. ® §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 PageA of 2 • Mandatory Measures Checklist: Residential (Page 2 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is Incorporated into 0 the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • • • .O • n 0 U 19 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ® '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum Installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam Insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 1- - U § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is Installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional Inlets and a circulation pump time switch. ® §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures a§ 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ® §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:2 of 2 00 • d rw 0 Certificate of Compliance: Residential p (Part 1 of 2) CF -1 R B O Y L E Main House 7/22/04 rojec Title -D-are-- 53-632 a e 53-632 via Bellagio La Quinta • ro/ecAddress_ w ing Permit C.M. Energy Consulting (760) 346-8014 Plan Check I Date Documentation Author a ep one Computer Performance 15 Vield CheckDate Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Frame Type Total Conditioned Floor Area: 3,009 ft2 Average Ceiling Height: Total Conditioned Slab Area: 3,009 ft2 Building Type: Exterior Roof (check one or more) Wood ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northeast) 45 deg Floor Construction Type: X❑ Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION 0.756 • • 0 11.4 ft Component Type Frame Type Assembly U -Value Location/Comments (attic, garage, typical, etc.) C/R-2 (R.38.2x .16) Wood 0.026 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade n1a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation C/R-1 (R.38.2x_.16) Wood 0.024 Exterior Roof C/R-3 (R.38.2x_.16) Wood 0.030 Exterior Roof FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Skylight 4.0 0.68 0.55 None ❑ X❑ ❑ x❑ Right (North) 17.5 1.19 0.83 Bug Screen X❑ ❑ ❑ X❑ Front (Northeast) 45.0 0.51 0.40 Bug Screen X❑ ❑ ❑ X❑ Left (Southeast) 10.0 0.51 0.53 Bug Screen x❑ ❑ ❑ x❑ Rear (Southwest) 91.8 0.51 0.53 Bug ScreenX❑ ❑ ❑ x❑ Front (Northeast) 70.0 0.51 0.53 Bug Screen X❑ ❑ ❑X❑ Left (South) 27.0 0.51 0.53 Bug Screen X❑ ❑ ❑ X❑ Rear (Southwest) 222.8 0.49 0.44 Bug Screen o ❑ ❑ o Right (Northwest) 52.0 0.51 0.53 Bug Screen © ❑ ❑ Right (Northwest) 72.0 0.49 0.44 Bug Screen N 1:1 El NFront (Northeast) 12.0 0.49 0.46 Bug Screen x❑ ❑ ❑ X❑ Front (Northeast) 10.0 0.57 0.67 Bug Screen ® ❑ ❑ X❑ Run Initiation Time: 07/22/04 09:36:51 Run Code: 1090514211 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:1 of 4 Certificate of Compliance: Residential p (Part 1 Of 2) CF -1 R B O Y L E Main House 7/22/04 rojec nue a e 53-632 Via Bellagio La Quinta •Project Address C.M. Energy Consulting (760) 346-8014 ocumen a ion Author I a ep one Computer Performance 15 • Building ermi Plan Check I Date ie eck I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,009 ft2 Total Conditioned Slab Area: 3,009 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Single Family Attached ❑ Multi -Family Average Ceiling Height: 11.4 ft ❑ Addition ❑ Existing Building ❑ Existing Plus Addition Front Orientation: (Northeast) 45 deg. Floor Construction Type: X Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION Component Type • fl • FENESTRATION L 111 • 0 ❑ Raised Floor Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Front (Northeast) 22.5 0.72 0.77 Bug ScreenX❑ ❑ ❑ x❑ Right (Northwest) 6.8 0.67 0.60 Bug Screen X❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 1:1 El El El El El 11 1:1 El 1:1 El El El El El Run Initiation Time: 07/22/04 09:36:51 Run Code: 1090514211 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Pagel of 4 0 • • • 0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Title/Firm: C.M. Energy Consulting B O Y L E Main House Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 7/22/04 Telephone: (760) 346-8014 rojec nue Lic. #: a e I V �2 HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. (signature (date) Enforcement Agency Distribution Name: Title/Firm: Equipment Minimum HeatingType and Duct or Telephone: Type (furnace, heat Efficiency Location Piping Thermostat Location / EnergyPro 3.1 By EnergySoft User Number. 1086 pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 (Kitchen) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 2 (Living Area) • Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 3 (Master Bed/Living) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Kitchen) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 2 (Living Area) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 3 (Master Bed/Living) WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value RHEEM HE 80-130 Large Gas Recirc/Time+Temp 1 130,000 80 0.95 0.0129 0.0 0 • • • 0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Micah Combs Title/Firm: McFadden/McIntosh Architects Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Palm D sert, CA 92260 Telephone: (760) 346-8014 Telephone: (760) 34"014/1 Lic. #: I V �2 signature (�g ) (date) (signature (date) Enforcement Agency Name: Title/Firm: Address: Telephone: signature stamp date Run Initiation Time: 07/22/04 09:36:51 Run Code: 1090514211 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:3 of 4 0 0 0 0 0 F, 0 Certificate of Compliance: Residential (Addendum) CF -1 R B O Y L E Main House 7/22/04 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies w W aucyuaUy yr ana QFV.aJUSMICauvn anu uwumeniauvn suumaieu. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 495 sgft Tile in Mortar Interior Mass, 0.75" thick at Kitchen HIGH MASS Design(see C-211) - Verify Thermal Mass: 495 sgft Exposed Slab Floor, 4.00" thick at Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 202 sgft Covered Slab Floor, 4.00" thick at Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 911 sgft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 911 sgft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C-211) - Verify Thermal Mass: 101 sgft Covered Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 931 sgft Tile in Mortar Interior Mass, 0.75" thick at Master Bed/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 901 sgft Exposed Slab Floor, 4.00" thick at Master Bed/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 399 sgft Covered Slab Floor, 4.00" thick at Master Bed/Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I an I Field e HVAG bystem LUNh 1 (Kitchen)" includes Retrigerant Cffa—rge 5n -d Airflow Gredit (ora certified HL115 rater mu st provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 1 (Kitchen)" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakac e performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "ZONE 2 ivmg Area)" includes Refrigerant Charge and Ai low Credit or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. e ys em wing res is using reduced uc leakage to comply and must have diagnostic site testing ol duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System (Master Be rvmg includes Refrigerant Charge and Airflow Credit (ora certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System (Master a wing is using reduced uc leakage to comply and must have diagnostic site tei fi—ng-o-r duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation I Ime: un Code: EnergyPro 3.1 By EnergySoft User Number: 1086 Job Number. 0316.00 Page:4 of 4 LJ • • May 12, 2004 -2- Project No. 544-4244 04-05-327 The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report remain applicable for the design and construction of the proposed residential structure foundations. Because the lot has been previously rough graded, the remedial grading required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted so that a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at. least 90 percent relative compaction. Allowable Bearing Pressures: The allowable bearing. pressures recommended in the grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. An allowable increase of 300 psf for each additional.1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. The bearing soils are non -expansive and fall within the "very low" expansion category in accordance with Uniform Building Code (UBC) classification criteria. Pertinent 1997 UBC Seismic Design parameters are summarized on the attached data sheet. If you have questions regarding this letter or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEE N Q\ypF ESS�O� A1VpF��l�2 2 2 Brett L. An � ers W Exp. 9/30/06 Principal Engineer �t CIVI\, a� SER/pc OFe��\�C�� Copies: 4/Mc Fadden/McIntosh Architects Sladden Engineering • May 12, 2004 -3- 1997 UNIFORM BUILDING CODE INFORMATION Project No. 544-4244 04-05-327 The International Conference of Building Officials. 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section in Chapter 16.. Concepts contained in the code that will be relevant to construction of the proposed structure are summarized below. Ground shaking is expected to be the primary hazard most likely to affect the site, based upon proximity to significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 UBC) San Andreas 9.8 km A San Jacinto 26 km A Based on our field observations and understanding of local geologic conditions, the soil profile • type judged applicable to this site is So, generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. • Sladden Engineering Near -Source Near -Source Seismic Seismic Seismic Acceleration Velocity Coefficient Coefficient Source Factor, Na Factor, N„ Ca C� San Andreas 1.01 1.22 0.44 Na 0.64 N� San Jacinto 1.0 1.0 0.44 N. 0.64 N� Sladden Engineering CIHIEIEIMS Registry:: Site:: Structure Details ' Page 1 of 1 Structure Number 1 Address 53709 Via Bellagio La Quinta, California 92253 Number of 1 Dwelling Units Project Participation 2001: Title 24 Project . Boyle Residence Floorplan' Boyle Residence Grouping Phase 1 _ Statistics ' U Verification Tested Number of 17 Verifications Ducts Complete Latest Feature Verification Tt es Status Distribution System is Fully Ducted Tested 09/22/2005 Complete r -�.-�.re... - . s .,.w,.. �•...� ...._:... n.. ......,. .�.-r. -..... ..c,: ,.:......�+iF� -- — ...w��. Proper Duct Sealing /Tape - -�. f. Tested •.ti. ..--...ter.-. 09/22/2005 . w,,.r , �» Complete +-'P � .,mow -«.n.. � .--. -- - ..,..—�:..-+. �..c...-sem +.r.<w....... aa►-.... ... •.i.aw. -• .a ......... _ +.. .-, -.. -. Tested Duct Leakage Tested 09/22/2005 Complete HVAC Equipment Complete Latest Feature I Verification Tes i Status Thermostatic Expansion Valve Tested 09/22/20051t Complete Structure Envelope Complete Latest Feature Verification Test Status CF -6R Verification ' Tested 09/22/2005 Complete © 2000 - 2005 CIHIEIEIRIS Page: 2.2486 Questions or Comments http://registry.cheers.org/indei.php?Realm=Site&Action=Detail&SiteID=109273 .10/20/2005 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Protect Title Date ��- Iy/a I&I �—,qfic, &e- 1 1 ProjectAddress Builder Name Builder Contact Telephone Plan Number /Ll, c�� �� G✓, I/e�� &I( -(,q - 7-7-L/5 HERS Rater Certifying Signature Finn: Street Address: Copies to: Builder, HERS Provider Telephone Date Sample Group Number Sample House Number HERS Provider: City/State/Zip: HERS RATER COMPLIANCE STATEMENT The house was: Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Measuredvalues Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) A—Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1' ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2' ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. l Measured Fan Flow = ❑ ❑ Yes for both.1 and 2 is a Pass Pass Fail Compliance Forms August 2001 A-16 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Protect Tile Date T/, 3 - 70q Yza & // G, _&6.LL. Prolec Address Builder Name Rater Signature Telephone -7 9� Date Firm: Q Street Address: Copies to: Builder, HERS Provider Plan Number S • Sample -Group -Number—..—__ - Sample House Number HERS Provider: c e4 City/State/Zip: ���,,,, � HERS RATER COMPLIANCE STATEMENT The house was: Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply . with the diagnostic tested compliance requirements as checked on this form. MA The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM_ If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) Check Box for Pass or Fail (Pass=6% or less) ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is in and Access is provided for inspection Yes is a pass ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT l ❑ Yes ❑ No ACCA'Manual D Design requirements have been met (rater has verified,that actual installation matches values in CF -IR and design on plan. 2. ❑ Yes 0 No TXV is installed or Fan flow has been verified. If no TXV,. verifiedfanflow matches design from CF -1R. Measured Fan Flow Yes for both 1 and 2 is a Pass: Compliance Forms August 2001 1 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Project Tale Date Proiec) Address Builder Name Builder Contact Telephone Plan Number til eLiY9-7�7_L/ HERS Rater _ _ _ _ _Telephone___ __ Sample_Group_Number —____ Certifying Signature Date Sample House Number Firm: Q Street Address: ys - 9�� �Gn o r'. Copies to: Builder, HERS Provider HERS Provider: _,6""c e/ A,/, //p' City/State/Zip:_����',4 gU HERS RATER COMPLIANCE STATEMENT The house was: Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply . with the diagnostic tested compliance requirements as checked on this form. The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Measuredvalues Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton is number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) Check Box for Pass or Fail (Pass=6% or less) fit ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection Yes is a pass ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified,that actual installation matches values in CF -1R and design onplan. 2. ❑Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV). verified fan flow matches design from CF -1R. Measured Fan Flow Yes for both 1 and 2 'is a Pass:' Compliance Forms August 2001 Pass Fail 13 -.13'. Pass Fail A-16 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Project Tittle Date / ll Projecs 'Address Builder Name Builder Contact Telephone Plan Number tif, G✓, '/((I-7�7_L1 S HERS Rater _ _ Telephone ___._.__Sample_Group_Number —._-.- ._ Certifying Signature U Date Firm: Street Address: lG;,-,plzz,� Copies to: Builder, HERS Provider Sample House Number HERS Provider: 1,e�4 Gj , /" /,) City/State/Zip: 19 J � (, HERS RATER COMPLIANCE STATEMENT The house was: Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply . with the diagnostic tested compliance requirements as checked on this form. The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = SSL� Check :Box for Pass or Fail (Pass=6% or less) ❑ ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) 2 Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ Yes is a pass P Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified,that actual installation matches values in CF -1R and design on plan. 2• ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV,. verified fan flow matches design from CF -1R. } Measured Fan Flow Yes for both 1 and 2 is a Pass, Pass Fail Compliance Forms August 2001 A-16 Jan 24 05 12;00a -CAL-SURV,INC. E= ' January 2.4, 2005 ENGINEERING DEPARTMENT CITY OF LA QUINTA ?8-495 Calle Tampico La Q-.linta, CA 92253 Re: Bovie Residence 531709 Via 3ellagio La Quinta, Ca SCi30207 951-788-8200 p,1 CAL -SUR V INC.. A California Land Survey Corporation City Engineer: Based on a field survey of the subject site, I observed the concrete forms for location and grade, and ,found the forms to be in substantial conformance (±0.10' vertical) with the finish floor grade of 1005.00 as shown on the approved precise grading plan plus 14" for a Top of form grade of 1005.12. Said forms do not encroach within the building setbacks. if you have any questions or require a copy of my field notes please contact me at the nu.-nber shown below. Sincerely, CAL-SURV, INC. Andrew Y. Orosco L.S.5491 Project Manager �J('rlfit 913Cr200V .""' F CSL "Surveying Today For California's Tomorrow" P.O.BOX 1249 • RIVERSIDE, CALIFORNIA • 92502 • (951)788-8357 P.0 -BOX 11153 • PALM DESERT, CALIFORNIA • 92255 • (877)788-8357 • • 0 'o J n 0 0 TITLE 24 REPORT Title 24 Report for: B O Y L E Guest House ,.z --L' 989M Via Bellagio 516,-307 La Quinta, CA 92253 Project Designer: McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 j Report Prepared By: Micah Combs C.M. Energy Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Job Number: 0316.00 Date: 6/1/04 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE-BY --4s-: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0316.00 User Numhec 10—RA • LJ Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into `) the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • 0 0 is 0 U 0 41 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ®'§ 150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. ®'§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§ greater than 2.0 pemVnch. ® § 118: Insulation specified or installed meets insulation quality standards. Indicate type and forth. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. a§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ® § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:1 of 2 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into {_ the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • 4D • • • • 0 • DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT'. JI Space Conditioning, Water Heating and Plumbing System Measures: (continued) ®'§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. I 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. i a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. i 3. Pool system has directional inlets and a circulation pump time switch. ® §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria I Lighting Measures FX] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessiblelighting control panel at an entrance to the kitchen. ® §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. R J 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:2 of 2� • 0 • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R B O Y L E Guest House 6/1/04 Project Titie Date 53-709 Via BeIIagio La Quinta Project Address • C.M. Energy Consulting (760) 346-8014 Documentation Author a ep one Computer Performance 15 • • • O • U, • l) 0 Building ermit. Plan Check Date Field ec Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 643 ft2 Average Ceiling Height: Total Conditioned Slab Area: 643 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southwest) 225 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Frame Type Type C/11-2 (R.38.2x_.16) Wood W-1 Wall (W.21.2x6.16) Wood Slab On Grade Na Slab On Grade nla rtNt, 1 KA 1 IUN Assembly Location/Comments U -Value (attic, garage, typical, etc.) 0.026 Exterior Roof 0.057 Exterior Wall 0.756 Exposed Slab w/R-0.0 Perimeter Insulation 0.756 Covered Slab w/R-0.0 Perimeter Insulation Sharlinn navicac 9.1 ft Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Right (Southeast) 72.0 0.49 0.44 Bug Screen X❑ ❑ ❑ ❑x Right (Southeast) 4.5 0.67 0.60 Bug Screen ] ❑ ❑ x❑ Front (Southwest) 27.0 0.51 0.40 Bug Screen X❑ ❑ ❑ X❑ Front (Southwest) 4.5 0.51 0.53 Bug Screen X❑ ❑ ❑ a Left (Northwest) 72.0 0.49 0.44 Bug Screen X❑ ❑ ❑ X❑ Left (Northwest) 4.5 0.67 0.60 Bug Screen X❑ ❑ ❑ - ❑ ❑ ❑ ❑ El El El El El El F] ❑❑ 1:1 El Run Initiation Time: 06/01/04 09:01:02 Run Code: 1086105662 EnergyPro 3.1 By Energysoft User Number. 1086 Job Number. 0316.00 Page:1 of 3 • Certificate of Compliance: Residential (Part2 of 2) CF -1R B O Y L E Guest House 6/1/04 ` rotec i e Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. • Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 (Guest House) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments • Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Guest House) • WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value CONTINUUM RINNAI Instant Gas Point of Use 1 199,000 0 0.82 0 n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author • Name: Title/Firm: Address: • 0 McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert. CA 92260 Title/Firm: Address: Telephone: Name: Micah Combs Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Telephone, (769) 346-8j?14 n (signdture) �- (date) signature stamp) date Run Initiation Time: 06/01/04 09:01:02 Run Code: 1086105662 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:2 of 3 • Certificate of Compliance: Residential (Addendum) CF -1 R ,---B O Y L E Guest House 6/1/04 roject Title Date aper-im reawres ano mooenng Assumptions • The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies • • 0 n U ... ,.. a..a —1—Y — all` area — Juaaula sewil —lu UWUUJloci IIiRIVII -Jumilluuu. Plan Field HIGH MASS Design(see C-211) - Verify Thermal Mass: 264 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 264 sgft Exposed Slab Floor, 4.00" thick at Guest House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 379 sgft Covered Slab Floor, 4.00" thick at Guest House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS .Ode- Yk- UCO C .-6--.......• J- 6_ c_l 1V1111 %,V-uR. an Re lcl e HVAG bystem(Guest House)- includes Ketrigerant Charge and Airtlow Credit (ora certiffed HF -K5 rati provide verification of the TXV, or measure the Refrigerant Charge and Airflow. r mus Run InitiationTime: un Code: 1086105662 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0318.00 Pagel of 3 0 a • Computer Method Summary (Part 1 of 3) C -2R -6 O Y L E Guest House 6/1/04 ro/ec i e Mate— -- -- -- -53-709 Via Bellaqio La Quinta Project Aaaress C.M. Energy Consulting (760) 346-8014 -D-ocumentation Author Te ep one Computer Performance 15 corn liance method W-1— e or om u er ---------- Building Permit 9--- -� I Plan Checkmate - e ec a e — J p g p 643 ima a one -- Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.79 2.64 1.15 Space Cooling 51.45 66.05 -14.59 Domestic Hot water 30.31 13.06 17.25 Totals -95--.55 81.74 3.81 Percent better than Standard: Wall 82 4.5% 0 Total Conditioned Floor Area: 643 ft Building Type: Single Fam Detached Building Front Orientation: (Southwest) 225 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Construction Type: ❑ Raised Floor ® Slab Floor Total Fenestration Area: 28.7% Total Conditioned Volume: 5,851 ft 3 Total Conditioned Slab Area: 643 ft 2 # of Floor Area Volume Units Zone Type ZONE 1 (Guest House) 643 W Sof OPAQUE SURFACES Act. Gains Type Area U -Fac Azm Tilt . Y / N Roof 643 0.026 0 0 Wall 115 0.057 0 90 Wall 130 0.057 45 90 • Wall Wall 100 0.057 135 180 90 92 0.057 90 Wall 162 0.057 225 90 Wall 82 0.057 315 90 El 0 5.851 1.00 Conditioned Form 3 Reference C/R-2 (R.38.2x_.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) Thermostat Type Setback Vent Hgt. Area Location / Comments ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY 2 n/a Run Initiation Time: 06/01/04 09:01:02 Run Code: 1086105662 j EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:1 of 4 1 • Computer Method Summary (Part 2 of 3) C -2R O Y L E Guest House 6/1/04 Date U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Right (Southeast) 72.0 0.490 0.44 • 135 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 2 Window Right (Southeast) 4.5 0.670 0.60 135 90 Double Tinted Default (NW) ZONE 1 ONLY 3 Window Front (Southwest) 27.0 0.510 0.40 225 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 4 Window Front (Southwest) 4.5 0.510 0.53 225 90 Sierra Pacific Mtl. Clad _ ZONE 1 ONLY 5 Window Left (Northwest) 72.0 0.490 0.44 315 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 5 Window Left (Northwest) 2.2 0.670 0.60 315 90 Double Tinted Default (NW) _ ZONE 1 ONLY _ 7 Window Left (Northwest) 2.2 0.670 0.60 315 90 Double Tinted Default (NW) ZONE 1 ONLY INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC -gt�d Len. Hgt. LExt. REit. ist. en. Hgt. Dist. Len. gt. Bug Screen 2 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 - 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 - 4 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7- Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Run Initiation Time: 06/01/04 09:01:02 Run Code: 1086105662 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:2 of 4 0 • Computer Method Summary (Part 3 of 3) C -2R .r-.6 O Y L E Guest House 6/1/04 THERMAL MASS FOR HIGH MASS DESIGN Ratedl 1 Tank Insul. Tank Energy Fact? Area Thick. Heat Standby R -Value Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 264 0.75 24 0.67 n/a 0 ZONE 1 ONLY / Interior Mass Concrete, Heavyweight 264 4.00 28 0.98 Na 0 _ ZONE 1 ONLY /Slab on Grade Concrete, Heavyweight 379 4.00. 28 0.98 n/a 2 ZONE 1 ONLY / Slab on Grade 0 PERIMETER LOSSES 0 El F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 4 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 104 0.76 0.0 0 ZONE 1 ONLY HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Central Furnace 80%AFUE Ducts in Attic Oydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. 0 Duct Thermostat R -Value Type 4.2 Setback Location / Comments ZONE 1 (Guest House) _ Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Guest House) . WATER HEATING SYSTEMS Ratedl 1 Tank Insul. Tank Energy Fact? Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. CONTINUUM RINNAI V2532W Instant Gas Point of Use 1 199,000 0 0.82 0 n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS I Run Initiation Time: 06/01/04 09:01:02 Run Code: 1086105662 1 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:3 of 4 1 0 • Computer Method Summary (Addendum) C -2R - B O Y L E Guest House 6/1/04 _ roject Title Date • The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies • • • • U • 0 iaacu VII 11— aYN;4"a{.r VI 1110 01.001daI )4.10%, 1W11VII allu uVGulllCllla{Iull .7uU111111Cu. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 264 sgft Tile in Mortar Interior Mass, 0.75" thick at Guest House HIGH MASS Design(see C-211) - Verify Thermal Mass: 264 sgft Exposed Slab Floor, 4.00" thick at Guest House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 379 sgft Covered Slab Floor, 4.00" thick at Guest House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS 1.v -.r v.. ...v ..r..v .u.... ..• ... .—IJI VQ- l --Ulla VI 111C.1C IIICaZPL1I WJ VII a IVtlll Vr-o R. an ie lCl 11-ne HVAG bystem(Guest House)" includes Keffigerant charge and Airflow Credit (ora ce ire ra rovide verification of the TXV, or measure the Refrigerant Charge and Airflow. r mus Run InitiationTime: un Code: 1086105662 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0318.00 Page:4 of 4 • • LUM :m • 0 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 B O Y L E Guest House 6/1/04 •1 • -I •1 •1 •1 40 DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ASSEMBLY NAME jC/R-2 (R.38.2x_.16) Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor. Plywood 4 TYPE Wall (check one) 5 ILI / Roof Gypsum or Plaster Board .� WCeiling 0.39 8 H N FRAMING MATERIAL yy 1.39 =O Z FRAMING % 10% Framing /o 0.610 41.19 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) •1 • -I •1 •1 •1 40 SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.39 8 3.86 9 1.39 2.60 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ (� ® ❑ El El 0.170 0.250. 0.010 0.625 2.000 1.500 0.625 0.800 11.880 38.000 11.385 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.210 0.210 0.060 0.060 0.775 0.775 0.800 11.880 38.000 11.385 0.562 0.562 0.39 1.36 3.86 0.36 1.39 2.60 0.610 0.610 41.19 25.65 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 1 / Rc 1 - (Fr% / 100) 2.50 0.24 0.60 0.06 0.35 0.02 1.77 0.29 0.51 3.49 0.39 1.36 3.86 0.36 1.39 2.60 0.26 0.68 14.3 TOTAL HC 4.6 mu RI *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members [ 0.0243 X 0.90 ] + L 0.0390 X 0.10 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U-VALUI I EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 PageA of 2 7 • 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 B O Y L E Guest House 6/1/04 0 1 •1 :-Ml E01 40 DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ASSEMBLY NAME W-1 Wall (W.21.2x6.16) Stucco 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Plywood 4 TYPE Wall (check one) 5 WC Ceiling / Roof 0.31 W 0.37 8 2.60 FRAMING MATERIAL yy� 0.68 ? O % FRAMING 0 15 �o Framing % 0.680 23.111 15%(16 n o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) 0 1 •1 :-Ml E01 40 SUBTOTAI R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ ❑ El❑ El El 0.170 0.875 0.010 0.375 5.500 0.625 0.465 21.0001 5.445 0.562 0.562 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.0001 5.445 0.562 0.562 0.31 2.631 0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.111 7.56 *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.1323 X 0.15 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.631 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3.7 i It: weight and specitic Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X0.85 ] + [ 0.1323 X 0.15 1 / Rc 1 - (Fr-/./ 100) 1 / Rf Fr% / 100 ASSEMBLY U-VALUI EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:2 of 2