Loading...
12-0136 (AR)P.d BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number:1-2-0,`0000-13-6 Property Address: '47045` VIA -ANTIBES APN: 643-160-016-142 -26152 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application .valuation: 5400 Applicant:. Architect or Engineer: `I m ------------------ LICENSED CONTRACTOR'S DECLARATION uf�itt�v BUILDING'& SAFETY DEPARTMENT BUILDING PERMIT .I hereby affirm under penalty of perjury that I am licens under provisions of.Chapter 9 (commencing with Section 7000) of Division 3 of the sin ss d Proles nals Code, and my License is in full force and effect. Licepse Class: B' C46 License No.: 856729 Date: 1 -24ZC tractor: .. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I ani exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code)or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by . any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1—) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). . (_ 1 I am exempt under Sec. . , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:. Lender's Address: LQPERMIT Owner: PUCELLI,NANCY & EUGENE A 47045 VIA ANTIBES LA QUINTA, CA 92253' Contractor: WRIGHT BUILDING CO 71683 MIRAGE ROAD RANCHO MIRAGE, CA 92270 (760)776-1594 Lic. No.: 856729 f VOICE (760) 777-7012 FAX (760) -777-7011- INSPECTIONS (760) 777-7153 Date: 4/19/12 APR 19 2012 OF LA ----------------------------------------------- '+ WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: ' Carrier STATE FUND Policy Number 0022022-2011 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any man o as to become s bject to the workers' compensation laws of California, and agree that, ' I sho d ba�me sabje to the workers' compensation provisions of Section 3700of the La orCo Iorthwi h comply with those provisions. A scant: WARNING: FAILU TO SECURE WORKERS' *COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL ' SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for Whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and holo harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state th th abo inform 'on is correct..I agree to comply with all city and county ordinances and state laws relating to bus ing 99nstruc o ,and hereby authorize representatives of thi `county to enter upon he above-mentioned TpV,for, tt ape on urposes.al 'nature (Applicant or Agent Application Number. . . . . . 12-00000136 ------ Structure Information 80SF ADDITION/VB/RES-3 [ENGINEERED] -----. Other,struct info CODE EDITION 2010• FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 80.00 Permit . . . .BUILDING. PERMIT Additional desc . Permit Fee . . . . 81.'00 Plan Check Fee 52.65 Issue Date Valuation 5400 Expiration Date 10/15/12 Qty Unit Charge Per Extension BASE FEE 45.00 4.00 9.0000 THOU BLDG 2,001-25,000 ---------------------------------------------------------------------------- 36.00 Permit . . . ELECT -'ADD/ALT/REM Additional desc . Permit Fee 17.80 Plan Check Fee Issue Date Valuation 0 Expiration Date 10/15/12 Qty Unit Charge.'Per Extension ' \ BASE FEE 15.00' 80.00 .0350 -ELEC NEW RES - 1 OR 2 FAMILY. 2.80 ------------------------------------------------------------------------------ Special Notes and Comments 80SF LIVING ROOM ADDITION - PATIO ENCLOSURE/VB/RES-3/CLASS A [ENGINEERED] THIS PERMIT DOES NOT INCLUDE PLUMBING OR MECHANICAL ALTERATIONS. 2010 CALIFORNIA BUILDING CODES. April 18, 2012 9:18:36 AM AORTEGA Other Fees . . . . . . . . BLDG STDS ADMIN•(SB1473) 1.00 ENERGY REVIEW FEE 5.27 STRONG MOTION (SMI) -'RES 54 Fee summary. Charged Paid- Credited Due Permit Fee Total 98.80 .00 00 98.80 Plan`Check Total,. 57.10'. .00 .00 57.10 -Other .Fee• Total 6.81. .00 .00 _ 6.81_. Grand Total 162.71 .00 .00 162.71. Bin # i/ City. Of La QUinta BLdkrLng 8r Safety Division P•O. Box 1504,78-495 Calle Tampico La.QLdnta, CA 92253 -:(760) 777-7012 Building Permit "Application and Tracking Sheet Pen # � ,� ✓ Project Address: 770 V( ci AW,4y' er's Name:. ' cine r1 {►.�,�, /',,(f (,,/� r(,� 7Add A. P. Number.l� ` 1`�tJ�ol`p-� ress: g7Qg5 c'ii1 i1f7t���G� Legal Description:5( e ill' est` Q 1�. , ST, Zip: Cly'► 7 s3 Coatracto lKiTelephone: - :�K •- "� .:�;r Address:_76Project Description: City, ST, boa: hri I hero aa70 (Vln exi,,�4-11AQ`UcVI Qo Telephone-]bU-7% 0—�5_C/ `7 �� � "a �.n State Lia $Sb%)q City Lic # .g 73 O Q'I't�C�; t`eM 4e, AJwjL e .-I& Arch., Engr.,j sign _r6da � Ol�� ( _ Address: l ( i U t City., ST, Zip: 64 90�a Telephone: `7, 0-60L//'-08? x Construction Type:. Occupancy: State Lie. #: ` Project type one)' New dd'n Alter Repak Demo Name of Contact Person: [C lt:�.��t` f ` 1 Sq.. FL: Q S� #Stories �, # Units Telephone # of Contact Person: (p(j — $ g—� g Estimated Value of Project: 57 a co APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACING PERbW FEES-. Pian sets dl Pian Cheng submitted .. a I Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance.-' Tine 24 Calm Pians picked up Canstruc8on Flood plain plan Plans resubmitted... :`" " echafiied Giadiag plan 2'a Review, wady for correctio a Electrical SnbeoameMr List Called Contact Person:, Plumbing Grant Deed Pians packed up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE.- 7i° Review; ready for eorreetionslissae Developer Impact Fee Planning Approval. Called Contact Person P. Pub. Wks. Appr Date of permit issue School Fees Oil Total Permit Fees 1 ?. cowl OR- ����I M[Oa 1 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet detachedaccessory struchues.(spaces.that.do.not.contain.facilities for.living,.sleeping, .cooking,.eating-or-sanitation) oureplaeement.mobile .homes. Jt.has been determined that the,above-named owner is exempt.from,paying,school.fees at.this.time due.to.the.following.reason Residential Addition 500 Sq, Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to _ Education Code Section 17620 and Government Code 68995 Et Seq. in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that .building .permits and/or Certificates of.Occupancy for this square footage in this proposed,project may now be,issued. Fees Paid By Exempt -Pete Wright Check No. Name on the check " Telephone 7601776-1594 Funding . By Dr. Sharon P. McGehee Superintendent Fee collected Signature Barbuzza r. x Payment Recd $0.00 77 >- - . tver/tder, = NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the. date -on which the building.or installation, permit for this projectis issued, :or from.the.date on. which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE. Desert Sands Unified, School District wsc • q O ' 47950 Dune Palms Road Q BERMUDA OUNES O bate 4/19/12 La Quinta, CA 92253 RIANDIAN WELLLSE d No. 31261 (760) 771-8515 SERT PALM QUENTA �� ' QINDIO o Owner Nancy & Eugene Pucelli APN # 643-160-016 Address 47045 Via Antibes .Jurisdiction .La Quinta City La Quinta Zip 92253. Permit # Tract-# No -of Units Type Residential -Addition Lot•# ..No. Street S.F..,Lot-.# No. .Street S.F- Unit 1 47045 Via Antibes 80 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet detachedaccessory struchues.(spaces.that.do.not.contain.facilities for.living,.sleeping, .cooking,.eating-or-sanitation) oureplaeement.mobile .homes. Jt.has been determined that the,above-named owner is exempt.from,paying,school.fees at.this.time due.to.the.following.reason Residential Addition 500 Sq, Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to _ Education Code Section 17620 and Government Code 68995 Et Seq. in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that .building .permits and/or Certificates of.Occupancy for this square footage in this proposed,project may now be,issued. Fees Paid By Exempt -Pete Wright Check No. Name on the check " Telephone 7601776-1594 Funding . By Dr. Sharon P. McGehee Superintendent Fee collected Signature Barbuzza r. x Payment Recd $0.00 77 >- - . tver/tder, = NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the. date -on which the building.or installation, permit for this projectis issued, :or from.the.date on. which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting The Manag'e'ment Trust MONARCH GROUP DIVISION LAKE LA QWNTA HOMEOWAFERS ASSOCIATION January 31, 2012 Nancy Pucelli 47045 Via Antibes La Quinta, CA 92253 Re: 47045 ilia Antibes Architectural Request Dear Ms. Pucelh: The Architectural Committee has reviewed and approved your architectural request for the addition of 80 square feet, subject to obtaining all applicable, required, permits -of which a copy shall be submitted to the Management office. Sincerely, By Direction of the Board of Directors ., Rosie alla, CCAM Community Association Manager R RISC IVY° 'FEB 14, 2012 BY; y• a _ 39755 Berkey Drive, Suite A, Palm Desert, CA 92211 CONNECTING PEOPLE TO THE PROMISE PH: 760.776.5100 FAX: 760.776.5111 www.managementtrust.com BUILDING ENERGY ANALYSIS REPORT PROJECT: Pucelli Residence 47045 Via Antibes La Quinta, CA Project Designer:, I Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 7Rn-'1Ar%-1'1r%9 I CITY (5F LA QUINTA BUILDING & SAFETY DEPT. Job Number: P-MCIFWME) APPROVED FOR CONSTRUCTION APR 0 5 2012 y. ' Dat DATE e: BY: 4/3/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 6y Ener Soft User Number 2655 RunCode: 2012-04-03T11:05:11 ID: TABLE OF CONTENTS Cover.Page 1. Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Pucelli Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/3/2012 Project Address 47045 Via Antibes La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,410 Addition 80 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 2,330 Perim = 152' Existing we// Wood Framed R-13 2,992 Existing Door Opaque Door None 24 Existing Roof Wood Framed Attic R-22 6,357 Existing Slab Unheated Slab -on -Grade None 80 Perim = 15' New Wall Wood Framed R-19 348 New Roof Wood Framed Attic R-38 80 New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (W) 4.0 0.710 0.73 2.0 none Bug Screen Existing Front (M 30.0 0.710 0.73 2.0 none Bug Screen Existing Front (W) 13.3 0.710 0.73 2.0 none Bug Screen Existing Front (W) 20.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 8.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 6.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 25.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 30.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 6.0 .0.710 0.73 2.0 none Bug Screen Existing Rear (E) 18.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 64.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Pa e 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Pucelli Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/3/2012 Project Address 47045 Via Antibes La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,410 Addition 80 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Rear (E) 18.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 18.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 18.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 48.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 18.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 18.0 0.710 0.73 2.0 none Bug Screen Existing Rear (SE) 24.0 0.710 0.73 2.0 none Bug Screen Existing Right (SW) 18.0 0.710 0.73 2.0 none Bug Screen Existing Front (W) 25.0 0.710 0.73 2.0 none Bug Screen New Right (S) 16.7 0.710 0.73 2.0 none Bug Screen New Right (S) 10.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name PUCelli Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/3/2012 .SPECIAL FEATURES -INSPECTION .CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS. REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. r Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-04-03T1 1:05:11 ID: Pa e 5 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family 0 Addition Alone Date Pucelli Residence ❑ Multi Family 10 Existing+ Addition/Alteration 4/3/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 13.28 12.76 0.52 Space Cooling 191.26 191.68 -0.42 Fans 41.96 42.04 -0.08 Domestic Hot Water 18.69 18.69 0.00 Pumps 0.00 0.00 0.00 Totals 265.18 265.16 0.02 Percent Better Than Standard: 0.0 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (w) 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tom 1,100 92 Fuel Available at Site: Natural Gas (N) 600 75 Raised Floor Area: 0 (E) 1,200 160 Slab on Grade Area: 2,410 (S) 920 129 Average Ceiling Height: 9.9 Roof 6,437 0 Fenestration Average U -Factor: 0.71 TOTAL: 456 Average SHGC: 0.73 Fenestration/CFA Ratio: 18.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. /32012 Address 77-810 Las Montanas Road, Suite 201 Name ,loan D. Hacker Cit /State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sind Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner per Business & Professions Code) Company Address Name City/State/Zip Phone Signed License # Date Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Pucelli Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/3/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 2,330 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 809 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Living Door 24 1.450 None 270 90 Existing 4.5.1-A1 Existing Living Wall 525 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Living Wall 844 0.102 R-13 90 90 Existing 4.3.1-A3 Existing Living Wall 5161 0.102 R-13 180 90 Existing 4.3.1-A3 Existing Living Roof 6,3571 0.043 R-22 270 0 Existing 4.2.1-A6 Existing Living Wall 2301 0.102 R-13 270 90 Removec 4.3.1-A3 Existing Livin Wall 196 0.102 R-13 135 90 Existing 4.3.1-A3 Existing Living Wall 102 0.102 R-13 225 90 Existing 4.3.1-A3 Existing Livin Slab 80 0.730 None 0 180 1 New 4.4.7-A1 Addition Wall 175 0.074 R-19 270 90 New 4.3.1-A5 Addition Wall 173 0.074 R-19 180 90 New 4.3.1-A5 Addition Roof 801 0.025 R-38 270 0 New 4.2.1-A21 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 4.0 0.710 Default 0.73 1 Default 270 Existing Double Metal Clear Existing Living 2 Window 30.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 3 Window 13.3 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 4 Window 13.3 0.710 Default 0.73 Default 270 Removed Double Metal Clear Existing Living 5 Window 13.3 0.710 Default 0.73 Default 270 Removed Double Metal Clear Existing Living 6 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 7 Window 8.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 8 Window 6.0 0. 7101 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 9 Window 25.0 0. 7101 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 10 Window 30.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 11 Window 6.0 0.710 1 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 12 Window 18.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 13 Window 64.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 14 Window 18.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 15 Window 18.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 16 Window 18.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear I Existing Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID I Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Right Fin Len I Hat I LEA REA Dist Len H t Dist Len H t 1 Bug Screen 0.76 2.0 2.0 2.01 0.1 2.0 2.0 2 Bug Screen 0.76 6.0 5.0 2.01 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.8 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 6.8 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.01 2.0 7 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.01 2.0 8 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.8 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 16 Bu Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2012-04-03711:05:11 ID: Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Pucelli Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 141312012. OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments -------------- FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm I Status Glazin Type Location/Comments 17 Window 48.0 0.710 Default 0.73 Default 1801 Existing Double Metal Clear Existing Living 18 Window 18.0 0.710 Default 0.73 Default 1801 Existing Double Metal Clear Existing Living 19 Window 18.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 20 Window 24.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear Existing Living 21 Window 18.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear Existing Living 22 Window 25.0 0.710 Default 0.73 Default 270 New Double Metal Clear Addition 23 Window 16.7 0.710 Default 0.73 Default 180 New Double Metal Clear Addition 24 Window 10.0 0.710 Default 0.73 Default 180 New Double Metal Clear Addition (1) Ll -Factor Type: 2) SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Right Fin Len Hot LExt RExt Dist Len Hot Dist Len Hot 17 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 6.8 2.5 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 6.8 1.5 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-04-03711:05:11 /D: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project NameType Pucelli Residence Building 10Single Family 11 Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date 4/3/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Living Zone Existing Living 2,330 23,300 2006 Addition 80 640 Totals 801 2,330 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing ❑ WATER HEATING SYSTEMS S stem Name Qt . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. O. Smith FSG -50-224 2 Small Gas No Pipe Insulation 40,000 50 0.60 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 .ro v N Q *S� System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Pucelli Residence Date 1 4/3/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R; CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c . §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(1)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoff User Number 2655 RunCode: 2 0 1 2-04-03 711:05:11 ID: Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Pucelli Residence 1 4/3/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Pucelli Residence 4/3/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less 'than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Pucelli Residence 4/3/2012 System Name Floor Area Living Zone 2,410 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 4,167 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 74,000 62,603 3,303 1,083 54,467 Total Output Btuh 148,000 0 -Output Btuh/s ft 61.4 5,308 3,870 Cooling System 0 0 Output per System 40,000 0 0 0 0 Total Output Btuh 80,000 0 3,303 0 Total Output Tons 6.7 5,308 3,870 Total Output Btuh/s ft 33.2 Total Output s ft/Ton 361.5 73,220 62,207 Air System CFM per System 1,395 HVAC EQUIPMENT SELECTION Airflow cfm 2,790 BDP CO. 563AN042-A 52,532 21,232 148,000 Airflow cfm/s ft 1.16 Airflow cfm/Ton 418.5 Outside Air % 0.0% Total Adjusted System Output 52,532 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 21,232 148,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 69 OF 119 OF Outside Air 0 cfm Supply Fan Heating Coil 117 OF AL 2,790 cfm i ROOM 69 OF 4 70 IF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/67°F 80/67°F 62/61°F T_ Outside Air _40c 0 cfm Supply Fan Cooling Coil 64 / 62 OF 2,790 cfm 55.8% ROOM 80 / 67 OF 78 / 67 OF ' EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-04-03T11:05:11 ID: Page 13 of 13